You are on page 1of 2

1-4

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Modular Bay Computer


Package Rack 4U (CAS2xx) + FBP2xx
Case Case Case Case 40 40 80 80 T T T T for for for for use use use use with CT/VT (Compact size), IP52, pin-terminal connection, 4 slots without CT/VT (Compact size), IP52, pin-terminal connection, 6 slots with CT/VT (Medium size), IP20, pin-terminal connection, 14 slots without CT/VT (Medium size), IP20, pin-terminal connection, 15 slots

C264 L B 0 I 6 8 1 0 0 0 2 2 0 0 0 0 0 0 A 1 1 1 1 N 1 0 L

Note: 15 boards maximum in the rack type 'L'

Front Panel (GHU2xx)


Front Panel Leds and L/R switch - IP52 protection -GHU210 (40TE) or GHU211(80TE) Front Panel with Leds + Graphic Display LCD +L/R switch -GHU200(40TE) or GHU201(80TE) - IP52 prot. Simple Blind front panel : GHU220 (40TE ) or GHU 221(80TE) Detachable Front Panel with Graphic Display 40TE (GHU200) + Simple Blind Front panel (GHU22x) Detachable Front Panel with Graphic Display 80TE (GHU201) + Simple Blind Front panel (GHU22x) Detachable Front Panel with Leds 40TE (GHU210) + Simple Blind Front panel (GHU22x) Detachable Front Panel with Leds 80TE (GHU211) + Simple Blind Front panel (GHU22x)

Note: No cable needed

Language (including: Front Panel Labels, HMI)


French ( English) English (English) Spanish (English) German (English)

Power Supply and Legacy Ports (BIUxxx)


BIU241-A01 : VA,nom: 24 VDC / Nominal wetting voltage for 2DI: 24 VDC BIU241-A02 : VA,nom: 48 to 60 VDC / Nominal wetting voltage for 2DI: 48/60 VDC BIU241-A03 :VA,nom: 110 to 125 VDC / Nominal wetting voltage for 2 DI: 110/125 VDC BIU241 A04 : VA,nom: 220 VDC and 115 to 230VAC / Nominal wetting voltage for 2 DI: 220 VDC

Factory Setted Legacy Ports N 1/2 on BIU board


Port N2: RS232 ; Port N1: RS232 Port N2: RS232 ; Port N1: RS485 Port N2: RS485 ; Port N1: RS485

6 8 1 0 0

CPU and Base Communication


CPU270(Type3), with 2*Ethernet RJ45, 64Mb FlashMemory, 1 ppm Oscillator accuracy (Ref CPU270 = 2071590A02 ) CPU270(Type3), with 2*Ethernet RJ45, 64Mb FlashMemory, 50ppm Oscillator accuracy (Ref CPU270 = 2071590A01)

For CPU with 2 serial links: Factory Setted Legacy Ports N 3/4
Port N3: RS232 (non isolated) ; Port N4: RS232 (non isolated) Port N3: RS485(ECU201) ; Port N4: RS485(ECU201) Port N3: Optical(ECU200) ; Port N4: Optical(ECU200)

Manufacturing Process
Automatic affectation (as standard) of the I/O modules in the basic rack

Harsh Environmental Coating


No Yes

Transducerless Measurements Unit - Direct measuring value acquisition: 4 CT + 5 VT


Without

Nominal wetting voltage for digital inputs (DIU200(-) or DIU211(+) or CCU200(-) or DSP210(-))
VA,nom: VA,nom: VA,nom: VA,nom: VA,nom: 24 V DC (- to earth) DIU200-A01 board or CCU200-A01 board or DSP210-A01 48/60 V DC (- to earth) - DIU200-A02 board or CCU200-A02 board or DSP210-A02 110/125 V DC (- to earth) - DIU200-A03 board or CCU200-A03 board or DSP210-A03 220 V DC (- to earth) : DIU200-A04 board or CCU200-A04 board or DSP210-A04 110-125 VDC (-to earth) - DIU200-A03 board or CCU200-A07 board (input setted if > 68% Vn)

Note: With rack 'L' & Wetting Voltage = 110/125 Vdc, 10 x DIU 210 boards maximum

Digital Input Module (16 DI), each with 16 digital inputs (DIU200A0x)
DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 DIU200 quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity = = = = = = = = = = = = = = = = 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Note: Additional board count must not exceed 13

Multi Tension-Peak-Current Digital Input Module (16 DI), each with 16 digital inputs DIU211
DIU200 & DIU211 cannot be used in the same rack

Note: Additional board count must not exceed 13

Digital Output Module (10 DO), each with 10 digital outputs (DOU200)
DOU200 DOU200 DOU200 DOU200 DOU200 DOU200 DOU200 DOU200 DOU200 quantity quantity quantity quantity quantity quantity quantity quantity quantity = = = = = = = = = 0 1 2 3 4 5 6 7 8

1-4

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Modular Bay Computer


DOU200 DOU200 DOU200 DOU200 DOU200 DOU200 DOU200 quantity quantity quantity quantity quantity quantity quantity = = = = = = = 7 8 9 10 11 12 13

C264 L B 0 I 6 8 1 0 0 0 2 2 0 0 0 0 0 0 A 1 1 1 1 N 1 0 0

Note: Additional board count must not exceed 13

Mixed Module (8 DI + 4 DO), each with 8 digital inputs and 4 digital outputs (CCU20x)
CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 CCU200 quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity quantity = = = = = = = = = = = = = = = = 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Note: Additional board count must not exceed 13 : CCU cannot be adjacent to TMU

DC 4 Analog Input Module (C or V transducer connection) each with 4 analogue inputs (AIU201)
AIU201 AIU201 AIU201 AIU201 AIU201 AIU201 AIU201 quantity quantity quantity quantity quantity quantity quantity = = = = = = = 0 1 2 3 4 5 6

Note: Additional board count must not exceed 13

DC 8 Analog Input Module (Current), with 8 analogue inputs (AIU211)


AIU211 AIU211 AIU211 AIU211 AIU211 AIU211 AIU211 quantity quantity quantity quantity quantity quantity quantity = = = = = = = 0 1 2 3 4 5 6

Note: Additional board count must not exceed 13

Analog output module (Currents) ,with 4 analogue ouputs (AOU200)


AOU200 AOU200 AOU200 AOU200 AOU200 quantity quantity quantity quantity quantity = = = = = 0 1 2 3 4

Note: Additional board count must not exceed 13

Ethernet-based Switch Unit (SWU20x) 0R Redundant Unit (SWR20x) OR Dual Humming Unit (SWD20x)
Without SWU200 - With four 10/100BaseT Ethernet ports (RJ45) SWU202- With two 100BaseF MultiMode Ethernet ports (ST) and four 10/100BaseT Ethernet ports (RJ45) SWU204- With two 100BaseF MonoMode Ethernet ports (SC) and four 10/100BaseT Ethernet ports (RJ45) SWR202 or SWR212 -With two 100BaseF MultiMode Ethernet ports (ST) + four 10/100BaseT Ethernet ports (RJ45) SWR204 or SWR 214 -With two 100BaseF MonoMode Ethernet ports (SC) + four 10/100BaseT Ethernet ports (RJ45) SWD202 or SWD212 - With two 100BaseF MultiMode Ethernet ports (ST) + four 10/100BaseT Ethernet ports (RJ45)

OK

Ethernet-based SCADA Communication Protocol ( to upper levels SCADA, DCS, Master Station, ...)
IEC 60870-5-104

Legacy Serial SCADA Communication Protocol (to upper levels: SCADA, DCS, Master station, etc)
Up to two SCADA links in: IEC 60870-5-101, DNP3, Modbus

1 1 1 N 1 0

Legacy IED communication protocols (To lower levels: Relays, PLC, RTU, etc)
Up to 4 IEDs links in: DNP3, MODBUS, IEC 60870-5-103, IEC 60870-5-101

User Application
Disabled Enabled ISaGRAF run-time for Programmable Logic, Automation, etc.

Specific Software Version


No Software loaded Option CD3: No Software loaded, delivered with one CD-ROM inc. the C264 software(PACIS V3) - Consult Marketing Option CD4: No Software loaded, delivered with one CD-ROM inc. the C264 software(PACIS V4) - Consult Marketing

Built in Application
Disabled Synchrocheck/Voltage Regulation/ Autorecloser enabled

Cable Lenght for Detachable Front Panel


No cable

You might also like