Introduction

S TRUCTURED G ROUND GROUNDING SYSTEM


INTRODUCTION

C ATA LO G W W - P CC B 04
Introduction

Table of Contents
How to Use This Catalog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 The Purpose of Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

GROUNDING ROADMAPS
Common Bonding Network (CBN) . . . . . . . . . . . . Service Entrance Grounding Roadmap . . . . . . . Data Center Grounding Roadmap . . . . . . . . . . . . Data Center Rack Grounding (Raised Floor) . . . . Telecommunications Room Grounding Roadmap Telecommunications Room Rack Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 .5 .6 .7 .8 .9
Grounding Roadmaps

EQUIPMENT & RACK GROUNDING KITS


Features and Benefits PANDUIT STRUCTUREDGROUND System for Data Center Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rack Grounding Strip Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Common Bonding Network (CBN) to Rack Jumper Kit . . . . . . . . . . Equipment Jumper Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Paint Piercing Grounding Washer Kits . . . . . . . . . . . . . . . . . . . . . . Electrostatic Discharge (ESD) Port Kit . . . . . . . . . . . . . . . . . . . . . . Retrofit Rack Grounding Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Thread-Forming Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bonding Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..... ..... ..... ..... ..... ..... ..... ..... ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 .11 .11 .12 .13 .13 .14 .14 .14
Equipment & Rack Grounding Kits

COMMON BONDING NETWORK (CBN) COMPONENTS


BICSI/J-STD-607-A Telecommunications Grounding Busbars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Telecommunications Grounding and Bonding Conductor Label Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Ring Terminal, Vinyl Expanded Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Code Conductor, Two-Hole, Long Barrel with Window Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17 Flex Conductor, Two-Hole, Long Barrel with Window Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Code/Flex Conductor HTAP Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Code/Flex Conductor HTAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Clear Covers for HTCT HTAPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Grounding Clamp, U-Bolt, Bronze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Grounding Clamp for Water Pipes, Bronze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Grounding Rod Clamp, Bronze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Common Bonding Network (CBN) Components

Crimping Tools

CRIMPING TOOLS
Hand Operated Plier Type Tool . . . . . . . . . . . . . . . . . . . . . . CONTOUR CRIMP Controlled Cycle Tools . . . . . . . . . . . . . . . Die Type, Manual Hydraulic, 14 Ton, Crimping Tool . . . . . . . Die Type, Battery Powered Hydraulic, 12 Ton, Crimping Tool CD-920 Crimping Dies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. .. .. .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 .24 .25 .26 .27

Technical Information

TECHNICAL INFORMATION
PANDUIT STRUCTUREDGROUND System for Data Center Grounding Application Standards . . . . . . . . . . . . . . .28 Specification Layout for Data Center Grounding per BICSI TDM Manual, 10th Edition . . . . . . . . . . . . . . . . . . . .29 Recommended Sizing of the Telecommunications Bonding Backbone (TBB) and Grounding Equalizer (GE) per J-STD-607-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Recommended Cable Sizes for Grounding Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Key Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

Index

INDEX
Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Related Catalogs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


How to Use This Catalog
Introduction

Common Bonding Network (CBN) page 4


Introduction Grounding Roadmaps

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Common Bonding Network (CBN)
PANDUIT STRUCTUREDGROUND System for Data Center Grounding is a complete, highly reliable line of products to ground your building and network equipment in compliance with BICSI TDM Manual, 10th Edition and J-STD-607-A, TIA-942, IEEE Std 1100 (IEEE Emerald Book), UL and CSA

Telecommunications Room (see roadmap on page 8)

Equipment & Rack Grounding Kits

Grounding Roadmaps

Data Center (see roadmap on page 6)


Common Bonding Network (CBN) Components

Crimping Tools

Service Entrance (see roadmap on page 5)


Technical Information

Index

See page 28 for PANDUIT STRUCTUREDGROUND System for Data Center Grounding Application Standards. For more data center grounding information, see www.panduit.com/dcgrounding.

Equipment & Rack Grounding Kits

Grounding Roadmaps pages 5-9


Introduction Grounding Roadmaps

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Data Center Grounding Roadmap
Complies with BICSI TDM Manual, 10th Edition and J-STD-607-A, TIA-942, IEEE Std 1100 (IEEE Emerald Book), UL and CSA Bonding screws are recommended to mount all panels, equipment, shelves, etc. to ensure electrical continuity between metallic components and the grounded rack Can be used to ground equipment mounted in cabinets which meet EIA-310-D; installer should bond all cabinet members to the rack grounding strip

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Data Center Rack Grounding (Raised Floor)

Introduction

Back of Rack Shown

Back of Racks Shown

Paint Piercing Grounding Washer Kit: RGW (see page 13)

3 4

Data Equipment Racks Bonding Screws are used to mount patch panels to the front of the rack: RGTBS (see page 14)

Grounding Roadmaps

5 3 1
Equipment & Rack Grounding Kits

Equipment Jumper Kit 24" L, 90 Bent: RGEJ (see page 12)

3
AC Panel* Telecommunications Bonding Backbone (TBB)

Electrostatic Discharge (ESD) Port Kit recommended for use on front and back of rack: RGESD (see page 13)

Equipment & Rack Grounding Kits

Common Bonding Network (CBN) Components

Common Bonding Network (CBN) Components

Rack Grounding Strip Kit: RGS (see page 11) Conduit Building Steel

Common Bonding Network (CBN) Components

Equipment Jumper Kit 36" L, 90 Bent: RGEJ (see page 12)


Crimping Tools

Common Bonding Network (CBN) Raised Floor Pedestal

Crimping Tools

2
Equipment Jumper Kit 24" L, 45 Bent: RGEJ (see page 12)

1
Technical Information

Copper Compression HTAP and Clear Cover: HTWC (see page 19)

Telecommunications Grounding Busbar (TGB) and Busbar Label (see page 15) Telecommunications Grounding and Bonding Conductor Label Kit: LTYK (see page 15)

Technical Information

Bronze, U-Bolt Grounding Clamp: GPL (see page 22)

Common Bonding Network (CBN) to Rack Jumper Kit: RGCBNJ (see page 11)

3
Index

Copper Compression, Two-Hole, Long Barrel with Window Lug: LCC-W (see pages 16-17)

Common Bonding Network typically #2 AWG bare copper code conductor is used underfloor

Index

*AC Panel should be grounded per NEC standards. Enclosure should be grounded per manufacturers specifications. A typical raised floor includes a multitude of metallic components which are connected together. It is the responsibility of the manufacturer and installer of the raised floor to insure all the raised floor metallic components are bonded which means that they are connected together electrically in accordance with applicable specifications. The PANDUIT Bonding/Grounding System does not insure required bonding of the raised floor metallic components.

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

Crimping Tools

Detailed Product Information pages 11-23


Technical Information

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Code/Flex Conductor HTAP
Introduction

For Making Parallel and Multiple Tap Connections on Code and Flex Conductors
Used to tap into continuous conductors as a splice or pigtailing Each HTAP terminates a wide range of conductor sizes and combinations of code and flex conductors Class G, H, I and Locomotive to suit a variety of applications Slotted design allows quick and easy assembly of conductor to HTAP using 3 PANDUIT 94 V-0 cable ties included
HTAP RUN

Grounding Roadmaps

TAP

Tap grooves are separated from one another allowing them to function independently so HTAP can be used with a single or multiple taps providing maximum design and installation flexibility Color coded and marked with PANDUIT die index numbers for proper crimp die selection Requires crimping tools and dies, see pages 25, 26 and 27 UL Listed and CSA Certified for applications up to 600V when crimped with PANDUIT and specified competitor crimping tools and PANDUIT crimping dies Tin plated to inhibit corrosion

Detailed Tool Information pages 24-27

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Die Type, Battery Powered Hydraulic, 12 Ton, Crimping Tool
Introduction

Two stage rapid advance hydraulic system minimizes cycle time Provides UL Listed and CSA Certified connections on PANDUIT PAN-LUG copper and aluminum lugs and splices and copper taps Open "C-Head" design allows easy loading of crimping dies and connectors, saves time Rubber boot on crimp head provides abrasion protection Ram automatically retracts when crimp cycle is complete

Grounding Roadmaps

Tool provided with two, high capacity 12 VDC rechargeable nickel-metal hydride batteries provides for continuous operation and eliminates "memory" build-up, one hour charge time Eight second crimp cycle time provides quick terminations, saves time Uses industry standard Makita* batteries and charger industry proven reliability easy to obtain from local retail sources Requires crimping dies, see page 27 Dies installed using spring loaded die retention pins no need for tools Crimp head rotates 360 degrees provides versatility for use in restricted spaces

Equipment & Rack Grounding Kits

W W RUN L H RUN L

W RUN

RUN

Equipment & Rack Grounding Kits

Part Number
CT-2931

Part Description Terminates PANDUIT PAN-LUG Compression Connectors: Copper compression lugs and splices for #8 AWG 750 kcmil code conductor Copper compression lugs and splices for #8 AWG 600 kcmil flex conductor Copper compression CTAPF taps for #10 AWG 3/0 AWG code conductor Copper compression CTAP taps for #8 AWG 4/0 AWG code conductor Copper compression HTCT taps for #14 AWG 250 kcmil code conductor, #14 AWG 4/0 AWG flex conductor Aluminum compression lugs and splices for #6 AWG 600 kcmil code conductor Aluminum compression HTAPS for #14 AWG 500 kcmil code conductor PANDUIT PAN-TERM Tubular Terminals for #8 AWG 250 kcmil code conductor

Std. Pkg. Qty. 1

TAP 1

Common Bonding Network (CBN) Components

TAP 2 TAP 1

TAP 3

TAP 1

TAP 2

TAP 1

HTCT6-6

HTCT2-2

HTCT250-2 Figure Dimensions (In.)

HTCT250-250

Copper Conductor Size Range Wire Strand Type Code Flex


HTCT2-2-1

Common Bonding Network (CBN) Components

Part Number
HTCT6-6-1

Run #6 - #10 AWG #6 - #10 AWG #2 - #6 AWG STR/SOL #2 - #8 AWG 250 kcmil #2 AWG 4/0 - #2 AWG 250 kcmil #2 AWG 4/0 - #2 AWG

Tap 1 #6 - #14 AWG #6 - #14 AWG

Tap 2

Tap 3

L .61

W .40

H .99

PANDUIT Crimping Tool CT-930, CT-2931

Wire PANDUIT Strip Std. Die Color Length Pkg. & Die No. (In.) Qty. Orange, 11/16 1 PH6
Crimping Tools

Warranty: 3 years CT-2931 includes: Tool Two 12 VDC, rechargeable NiMH batteries One battery charger Steel tool case with storage for batteries, charger and crimp dies
For the complete line of PANDUIT crimping tools and dies, see the Termination Solutions Catalog SA-TMCB02. CG-920 crimp force measurement gauge available, sold separately, see the Termination Solutions Catalog SA-TMCB02. *Makita is a registered trademark of Makita Corporation in the United States.

.76 .61 1.55 CT-930, CT-2931 Brown, PH2 13/16 1

Crimping Tools

Code Flex
HTCT250-2-1

#2 - #6 AWG #8 - #14 #8 - #14 STR/SOL AWG AWG #2 - #8 AWG #8 - #14 #8 - #14 AWG AWG #2 - #6 AWG #8 - #14 STR/SOL AWG #2 - #8 AWG #8 - #14 AWG 250 kcmil #2 AWG 4/0 - #2 AWG

Code Flex

.92

.96

1.92

CT-930, CT-2931

Purple, PH25

Technical Information

HTCT250-250-1

Code Flex

.90

.89

1.92

CT-930, CT-2931

Purple, PH25

Technical Information

For additional sizes and configurations and to see the complete line of PAN-LUG Power and Grounding Connectors, see the Termination Solutions Catalog SA-TMCB02.

Index

Index

Index

20

26

Technical Information Includes Application Standards and BICSI TDM Manual, 10th Edition pages 28-30
2

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

The Purpose of Grounding


The grounding system is not just an insurance policy against a lightning strike. It is an active, functioning system that provides protection for personnel and equipment. Proper grounding is essential for efficient network performance. The purpose of the grounding system is to create a low impedance path to earth ground for electrical surges and transient voltages. Lightning, fault currents, circuit switching (motors turning on and off), and electrostatic discharge are the common causes of these surges and transient voltages. An effective grounding system minimizes the detrimental effects of these electrical surges. A properly designed grounding system is one that is intentional, visually verifiable, adequately sized to handle expected currents safely, and one that directs these potentially damaging currents away from sensitive communication equipment. Any metallic component that is part of the data center infrastructure (such as equipment, racks, ladder racks, enclosures, cable trays, etc.) must be bonded to the grounding system.
Grounding Roadmaps Introduction

What are the effects of improper grounding?


Decreased Efficiency
Electrical noise is introduced on data cables when surges are not properly dissipated by the grounding system.They cause faulty data signals and dropped packets, thus decreasing the throughput and overall efficiency of your network.

Equipment & Rack Grounding Kits

Lower Reliability
According to insurance industry data, improper grounding of communication systems leads to $500 million per year of damage to property and/or equipment due to lightning. (1) The Information Technology Industry Council states that grounding is the single-most important factor in reliable network equipment performance. (2) More than 90% of problems in data communications equipment, including reboot, lockup, and data corruption, are traced to problems with grounding. (3) Industry experts estimate that 27%-33% of damaged equipment in a user's facility is caused by electrostatic discharge. The component cost of repairing damaged equipment is substantial for complex circuit boards, especially when labor and downtime are considered. (4) According to the IEEE, the typical AC third prong ground is almost never sufficient to prevent damage to network equipment. (5)
Common Bonding Network (CBN) Components

Safety Risks
Personal injury from electric shock caused by improper grounding can cause immeasurable human suffering and significant expense. Potential fire hazards exist when heat is generated from electrical surges that find a high resistance path to ground.

Crimping Tools

Can you afford improper grounding?


Network equipment, such as switches, routers and storage devices, costs anywhere from thousands of dollars to hundreds of thousands of dollars.The cost of proper grounding is only a tiny fraction of the cost of the equipment it is protecting. Clearly the biggest cost of improper grounding is the inability to service customers properly. PANDUIT STRUCTUREDGROUND System for Data Center Grounding gives you what you need to properly protect your investment.
1. Mike Holt, "Prevent Shocks in Your Communications: Understanding How the NEC Relies on Ground Resistance Theory Leads to a Successful Application of Communications Grounding," Electrical Construction & Maintenance, September 2002. 2. Information Technology Industry Council (ITI, formerly CBEMA), Guidelines for Grounding Information Technology Equipment. Information Letter, ITI, 15 February 1997. 3. Donald G. Pennington and Paul Holzer, "Doing Battle with Those Ground Transients," Electronic Engineering Times, 8 January 1996. 4. ESDA, "Fundamentals of ESD: Part 1 An Introduction to ESD," 2001, <http://www.esda.org/basics/part1.cfm> (1 October 2004). 5. Institute of Electrical and Electronics Engineers, Inc., IEEE Recommended Practice for Powering and Grounding Electronic Equipment, IEEE Std 1100-1999, 1999. For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

Technical Information

Index

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Common Bonding Network (CBN)
PANDUIT STRUCTUREDGROUND System for Data Center Grounding is a complete, highly reliable line of products to ground your building and network equipment in compliance with BICSI TDM Manual, 10th Edition and J-STD-607-A, TIA-942, IEEE Std 1100 (IEEE Emerald Book), UL and CSA

Introduction

Telecommunications Room (see roadmap on page 8)


Grounding Roadmaps

Equipment & Rack Grounding Kits

Data Center (see roadmap on page 6)


Common Bonding Network (CBN) Components

Crimping Tools

Service Entrance (see roadmap on page 5)


Technical Information

Index

See page 28 for PANDUIT STRUCTUREDGROUND System for Data Center Grounding Application Standards. For more data center grounding information, see www.panduit.com/dcgrounding.

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Service Entrance Grounding Roadmap


Complies with J-STD-607-A and IEEE Std 1100 (IEEE Emerald Book) Grounding Equalizer (GE) is required when two or more Telecommunications Bonding Backbones (TBB) are used within a multi-story building; bond TBBs together with a GE at the top floor and at a minimum of every third floor in between Telecommunications Bonding Backbone (TBB)**
Introduction

2 3 5
Earth Ground

2
Grounding Equalizer (GE)

Conduit

1 6 3 7

Grounding Roadmaps

Equipment & Rack Grounding Kits

3
AC Panel* Cable Entrance
Common Bonding Network (CBN) Components

AC Service Entrance

3 4
Water Meter

4
Crimping Tools

Copper Compression HTAP and Clear Cover: HTWC (see page 19)

Bronze, Grounding Rod Clamp: WB (see page 23) connected by a cable to 2 (U-Bolt Grounding Clamp)

Bronze, U-Bolt Grounding Clamp: GPL (see page 22) connected by a cable to 1 (HTAP)

Telecommunications Main Grounding Busbar (TMGB) and Busbar Label (see page 15)
Technical Information

Copper Compression, Two-Hole, Long Barrel with Window Lug: LCC-W (see pages 16-17)

Telecommunications Grounding and Bonding Conductor Label Kit: LTYK (see page 15)

Bronze, Water Pipe Grounding Clamp: KP (see page 23)


Index

*AC Panel should be grounded per NEC standards. Enclosure should be grounded per manufacturers specifications. **Specification J-STD-607-A specifies different size conductors based on the length of the Telecommunications Bonding Backbone (TBB). See page 30 for Recommended Sizing of the Telecommunications Bonding Backbone (TBB) and Grounding Equalizer (GE) Per J-STD-607-A. For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Data Center Grounding Roadmap
Complies with BICSI TDM Manual, 10th Edition and J-STD-607-A, TIA-942, IEEE Std 1100 (IEEE Emerald Book), UL and CSA Bonding screws are recommended to mount all panels, equipment, shelves, etc. to ensure electrical continuity between metallic components and the grounded rack Can be used to ground equipment mounted in cabinets which meet EIA-310-D; installer should bond all cabinet members to the rack grounding strip

Introduction

Back of Racks Shown

3 4
Grounding Roadmaps

Data Equipment Racks

5 3 1
Equipment & Rack Grounding Kits

3
AC Panel* Telecommunications Bonding Backbone (TBB)

Common Bonding Network (CBN) Components

Conduit Building Steel

Crimping Tools

Common Bonding Network (CBN) Raised Floor Pedestal

1
Technical Information

Copper Compression HTAP and Clear Cover: HTWC (see page 19)

Telecommunications Grounding Busbar (TGB) and Busbar Label (see page 15) Telecommunications Grounding and Bonding Conductor Label Kit: LTYK (see page 15)

Bronze, U-Bolt Grounding Clamp: GPL (see page 22)

3
Index

Copper Compression, Two-Hole, Long Barrel with Window Lug: LCC-W (see pages 16-17)

*AC Panel should be grounded per NEC standards. Enclosure should be grounded per manufacturers specifications. A typical raised floor includes a multitude of metallic components which are connected together. It is the responsibility of the manufacturer and installer of the raised floor to insure all the raised floor metallic components are bonded which means that they are connected together electrically in accordance with applicable specifications. The PANDUIT Bonding/Grounding System does not insure required bonding of the raised floor metallic components.

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Data Center Rack Grounding (Raised Floor)

Introduction

Back of Rack Shown

Paint Piercing Grounding Washer Kit: RGW (see page 13)

Bonding Screws are used to mount patch panels to the front of the rack: RGTBS (see page 14)

Grounding Roadmaps

Equipment Jumper Kit 24" L, 90 Bent: RGEJ (see page 12)

Electrostatic Discharge (ESD) Port Kit recommended for use on front and back of rack: RGESD (see page 13)

Equipment & Rack Grounding Kits

Rack Grounding Strip Kit: RGS (see page 11)

Common Bonding Network (CBN) Components

Equipment Jumper Kit 36" L, 90 Bent: RGEJ (see page 12)


Crimping Tools

Equipment Jumper Kit 24" L, 45 Bent: RGEJ (see page 12)

Technical Information

Common Bonding Network (CBN) to Rack Jumper Kit: RGCBNJ (see page 11)

Common Bonding Network typically #2 AWG bare copper code conductor is used underfloor

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Telecommunications Room Grounding Roadmap
Complies with BICSI TDM Manual, 10th Edition and J-STD-607-A, TIA-942, IEEE Std 1100 (IEEE Emerald Book), UL and CSA Bonding screws are recommended to mount all panels, equipment, shelves, etc. to ensure electrical continuity between metallic components and the grounded rack Can be used to ground equipment mounted in cabinets which meet EIA-310-D; installer should bond all cabinet members to the rack grounding strip

Introduction

Back of Racks Shown


Grounding Equalizer (GE)

Grounding Roadmaps

Conduit

5 3 4
Equipment & Rack Grounding Kits

3 1 3
Telecommunications Bonding Backbone (TBB)

AC Panel*
Common Bonding Network (CBN) Components

2
Building Steel
Crimping Tools

1
Technical Information

Copper Compression HTAP and Clear Cover: HTWC (see page 19)

Telecommunications Grounding Busbar (TGB) and Busbar Label (see page 15)

Bronze, U-Bolt Grounding Clamp: GPL (see page 22)

Telecommunications Grounding and Bonding Conductor Label Kit: LTYK (see page 15)

3
Index

Copper Compression, Two-Hole, Long Barrel with Window Lug: LCC-W (see pages 16-17)

*AC Panel should be grounded per NEC standards. Enclosure should be grounded per manufacturers specifications. A typical overhead cabling system includes a multitude of metallic components which are connected together. It is the responsibility of the installer to insure all of the metallic components are bonded, which means that they are connected together electrically in accordance with applicable specifications. The PANDUIT Bonding/Grounding System does not insure required bonding of the overhead cabling system metallic components.

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Telecommunications Room Rack Grounding

Introduction

Aisle Ground typically #2 AWG insulated copper code conductor is used overhead

Back of Rack Shown

Bonding Screws are used to mount patch panels to the front of the rack: RGTBS (see page 14)

Grounding Roadmaps

Paint Piercing Grounding Washer Kit: RGW (see page 13)

Common Bonding Network (CBN) to Rack Jumper Kit: RGCBNJ (see page 11)

Equipment & Rack Grounding Kits

Equipment Jumper Kit 24" L, 90 Bent: RGEJ (see page 12) Electrostatic Discharge (ESD) Port Kit recommended for use on front and back of rack: RGESD (see page 13)

Common Bonding Network (CBN) Components

Rack Grounding Strip Kit: RGS (see page 11)

Crimping Tools

Equipment Jumper Kit 36" L, 90 Bent: RGEJ (see page 12)

Equipment Jumper Kit 24" L, 45 Bent: RGEJ (see page 12)

Technical Information

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Features and Benefits PANDUIT STRUCTUREDGROUND System for Data Center Grounding
Introduction

PANDUIT offers a variety of kits with premium components to ensure superior grounding with the highest reliability available. Provides highest reliability with an all-copper rack Incorporates a flexible design that can be used with grounding system to maintain data center system racks which meet EIA-310-D performance and protect network equipment Offers ease of installation no paint scraping required to Complies with data center standard TIA-942 and is UL bond racks; factory terminated jumpers simply Listed and CSA Certified bolt in place

Grounding Roadmaps

Rack Grounding Strip is made from high conductivity, low resistance wrought copper and tin plated to inhibit corrosion, providing the lowest impedance path to ground Jumper has UL, VW-1 flame rated green insulation and is factory terminated with copper compression, two-hole, long barrel with window lug; lug is UL Listed, CSA Certified and meets NEBS Level 3 with a single stud hole and slot which allows mounting for " to 5/8" hole spacing and accommodates stud sizes ", #12 and 6mm Paint Piercing Grounding Washer is made from hardened steel and electro zinc plated which inhibits corrosion to provide a superior bond between frame members on bolt-together racks Thread-Forming Screws are made from electro zinc plated steel and provide a bond to the rack by removing paint from threaded holes without creating metal shavings Electrostatic Discharge (ESD) Port is made from high conductivity, low resistance copper and tin plated to inhibit corrosion plus it functions as an ESD wrist strap hanger Electrostatic Discharge (ESD) Protection Sticker is provided in black and yellow for high visibility and easy identification as an ESD port Copper Compression HTAP is UL Listed and CSA Certified; used to make a highly reliable, permanent bond between the common bonding network and common bonding network (CBN) to rack jumper kit

Equipment & Rack Grounding Kits

Electrostatic Discharge (ESD) Port Kit (see page 13)

Common Bonding Network (CBN) Components

Rack Grounding Strip Kit (see page 11)

Crimping Tools

D B D

F
Technical Information

Equipment Jumper Kit (see page 12)

B
Index

C G
Common Bonding Network (CBN) to Rack Jumper Kit (see page 11)

10

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Equipment & Rack Grounding Kits


Introduction

Rack Grounding Strip Kits


Bonds up to 44 RU per rack EIA Universal mounting hole pattern
Std. Pkg. Qty. 1

Part Number
RGS134-1

Part Description Rack grounding strip; 78.65" length; .67" width; .05" thickness; provided with .16 oz (5cc) of antioxidant and three #12-24 x 1/2" thread-forming screws* 10 rack grounding strips; 78.65" length; .67" width; .05" thickness; provided with .16 oz (5cc) of antioxidant and 30 #12-24 x 1/2" thread-forming screws*

Grounding Roadmaps

RGS134-10-1

*An equal number of M6 x 12mm thread-forming screws also provided in each kit.

Equipment & Rack Grounding Kits

Common Bonding Network (CBN) to Rack Jumper Kit


Bonds the rack grounding strip to the CBN HTAP, included in kit, requires crimping tool and die; see the CT-930 crimping tool on page 25, the CT-2931 crimping tool on page 26 and the CD-930H-250 crimping die on page 27 HTAP is UL Listed and CSA Certified for applications up to 600V when crimped with PANDUIT and specified competitor crimping tools and PANDUIT crimping dies; see the Termination Solutions Catalog SA-TMCB02 for the complete line of PANDUIT crimping tools
Std. Std. Pkg. Ctn. Qty. Qty. 1 10
Crimping Tools Common Bonding Network (CBN) Components

Part Number
RGCBNJ660P

Part Description #6 AWG jumper; 60" length; 45 bent lug on grounding strip side; provided with .16 oz (5cc) of antioxidant, two #12-24 x 1/2" thread-forming screws* and a copper compression HTAP** for connecting to the CBN in sizes ranging from #2 AWG to 250 kcmil

*An equal number of M6 x 12mm thread-forming screws also provided in each kit. **HTAP also sold separately, see page 20.

Technical Information

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

11

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Equipment Jumper Kits
Introduction

Bonds network equipment to rack grounding strip Jumper kit available with both ends factory terminated to provide a bolt on solution Jumper kit available with one end factory terminated to attach to the rack grounding strip; free end accommodates unique equipment terminations Use jumpers with 90 bent lug, on grounding strip side, for high density grounding requirements up to one ground point per RU

Use jumpers with 45 bent lugs, on grounding strip side, for improved cable management Use 24" jumpers when network equipment ground point is located near the grounding strip side of the rack Use 36" jumpers when network equipment ground point is located away from the grounding strip side of the rack

Grounding Roadmaps

Part Number
RGEJ1024PH

Part Description #10 AWG jumper; 24" length; 45 bent lug on grounding strip side to straight lug on equipment; provided with .16 oz (5cc) of antioxidant and four #12-24 x 1/2" thread-forming screws* #10 AWG jumper; 24" length; 90 bent lug on grounding strip side to straight lug on equipment; provided with .16 oz (5cc) of antioxidant and four #12-24 x 1/2" thread-forming screws* #10 AWG jumper; 36" length; 90 bent lug on grounding strip side to straight lug on equipment; provided with .16 oz (5cc) of antioxidant and four #12-24 x 1/2" thread-forming screws* #6 AWG jumper; 24" length; 45 bent lug on grounding strip side to straight lug on equipment; provided with .16 oz (5cc) of antioxidant and four #12-24 x 1/2" thread-forming screws* #6 AWG jumper; 24" length; 90 bent lug on grounding strip side to straight lug on equipment; provided with .16 oz (5cc) of antioxidant and four #12-24 x 1/2" thread-forming screws* #6 AWG jumper; 36" length; 90 bent lug on grounding strip side to straight lug on equipment; provided with .16 oz (5cc) of antioxidant and four #12-24 x 1/2" thread-forming screws* #10 AWG jumper; 57" length; 90 bent lug on grounding strip side; provided with .16 oz (5cc) of antioxidant and two #12-24 x 1/2" thread-forming screws*

Std. Std. Pkg. Ctn. Qty. Qty. 1 10

#10 AWG equipment jumpers factory terminated on both ends

Equipment & Rack Grounding Kits

RGEJ1024PF

10

RGEJ1024PF

RGEJ1036PF

10

#6 AWG equipment jumpers factory terminated on both ends


RGEJ624PH Common Bonding Network (CBN) Components

10

RGEJ624PF

10

RGEJ636PF

10

#10 AWG equipment jumper factory terminated on one end


RGEJ1057PF Crimping Tools

10

#6 AWG equipment jumper factory terminated on one end


RGEJ657PF

#6 AWG jumper; 57" length; 90 bent lug on grounding strip side; provided with .16 oz (5cc) of antioxidant and two #12-24 x 1/2" thread-forming screws*

10

RGEJ1057PF

*An equal number of M6 x 12mm thread-forming screws also provided in each kit.

How to Select the Appropriate Equipment Jumper


Technical Information
3" or smaller
3" or larger

Index

Select 24" equipment jumpers with 90 lugs when equipment grounding connection is close to the grounding strip. Select 36" equipment jumpers with 90 lugs when equipment grounding connection is on the opposite side from the grounding strip.

Select equipment jumpers with 45 lugs for lower density applications or shallow depth equipment to provide improved cable management.

12

G ROUND GSystem DataFOR Center S TRUCTURED S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Paint Piercing Grounding Washer Kits
Bonds frame members on bolt-together racks No paint scraping required Green color coding to indicate bonding application
Introduction

Part Number
RGW-12-1

Part Description 12 paint piercing bonding washers for 3/8" stud size; .875 O.D.; provided with .16 oz (5cc) of antioxidant; for use with standard equipment racks: CMR19X84, CMR19X84S and CMR23X84 32 paint piercing bonding washers for 3/8" stud size; .875 O.D.; provided with .16 oz (5cc) of antioxidant; for use with 4 post rack NF4PR84 and data rack DR84 100 paint piercing bonding washers for 3/8" stud size; .875 O.D.; provided with .16 oz (5cc) of antioxidant

Std. Pkg. Qty. 1

RGW-32-1

1
Grounding Roadmaps

RGW-100-1

Electrostatic Discharge (ESD) Port Kit


Accommodates standard ESD wrist strap 4mm plug Can be mounted to front or back of rack for convenient access Bent 45, acts as a hook to hold wrist strap Barrel permanently marked with the protective earth (ground) symbol
Std. Pkg. Qty. 1

Equipment & Rack Grounding Kits

Part Number
RGESD-1

Part Description ESD port kit; provided with an ESD protection sticker, .16 oz (5cc) of antioxidant and one #12-24 x 1/2" thread-forming screw*

Contact your local electrical distributor for their selection of Electrostatic Discharge (ESD) wrist straps. *One M6 x 12mm thread-forming screw also provided in each kit. ESD port must be attached to a grounded member.

Common Bonding Network (CBN) Components

Crimping Tools

Technical Information

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

13

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Retrofit Rack Grounding Kits
Introduction

Provides a dedicated ground system to maintain system performance and protect network equipment when RGS rack grounding strip kit cannot be used (see page 11) Optimized for installation on 19" racks that meet EIA-310-D, with functioning equipment, and are deployed in the field

Provides a complete system of matched components that can be easily selected to save cost and labor Thread-forming screws eliminate the need to manually remove paint from the rack

Grounding Roadmaps

RGRKCBNJEJ
Network Equipment Lug (see pages 16-18)

RGRKCBNJ Std. Std. Pkg. Ctn. Qty. Qty. 1 10

Part Number
RGRKCBNJEJ

Equipment & Rack Grounding Kits Rack


Grounding Busbar RGRB19 HTAP (see page 20)

Rack Grounding RGRKCBNJ Kit RGRKCBNJEJ Grounding Jumper RGREJ696 or RGREJ696 RGREJ1096

Part Description Rack grounding kit to ground the rack and one piece of equipment; includes one RGRB19 busbar, one HTCT250-2-1 HTAP and two RGREJ696 grounding jumpers Rack grounding kit to ground the rack; includes one RGRB19 busbar, one HTCT250-2-1 HTAP and one RGREJ696 grounding jumper Rack grounding busbar; can be positioned anywhere on the rack; 19" length; tin plated; 14 holes arranged for flexibility in mounting; mounting hole sets have 1/2" spacing; provided with two #12-24 x 1/2" thread-forming screws* for mounting Grounding jumper; #6 AWG; 96" length; one end factory terminated to lug; provided with .16 oz (5cc) of antioxidant and four #12-24 x 1/2" thread-forming screws* and other mounting hardware as appropriate Grounding jumper; #10 AWG; 96" length; one end factory terminated to lug; provided with .16 oz (5cc) of antioxidant and four #12-24 x 1/2" thread-forming screws* and other mounting hardware as appropriate

10

RGRB19

10

10

Common Bonding Network (CBN) Components

Grounding Jumper RGREJ696 Rack Grounding Kit RGRKCBNJ

RGREJ1096

10

*An equal number of M6 x 12mm thread-forming screws also provided in each kit.

Thread-Forming Screws
Crimping Tools

Thread-forming, provides a bond to the rack by removing paint from threaded holes without creating metal shavings

Easily installed with 5/16" socket head wrench or flat blade screwdriver
Std. Pkg. Qty. 100 100

Part Number
RGTS-C RGTSM6-C Technical Information

Part Description Thread-forming grounding screw, #12-24 x 1/2" Thread-forming grounding screw, M6 x 12mm

Bonding Screws
Creates an electrical bond between painted patch panels and racks Serrations on bottom of screw remove paint from patch panel, thus providing metal-to-metal contact Thread-forming, provides a bond to the rack by removing paint from threaded holes without creating metal shavings Easily installed with Phillips screwdriver
Std. Pkg. Qty. 100 100

Index

Part Number
RGTBS-C RGTBSM6-C

Part Description Thread-forming bonding screw, #12-24 x 1/2" Thread-forming bonding screw, M6 x 15mm

14

G ROUND GSystem DataFOR Center S TRUCTURED S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Common Bonding Network (CBN) Components
C

UL
R

US

BICSI/J-STD-607-A Telecommunications Grounding Busbars


Comes pre-assembled with brackets and insulators attached for quick installation Use PANDUIT self-laminating laser/ink jet labels to identify busbars to meet TIA/EIA-606-A
No. of 5/16" hole sets, 5/8" spacing 4 6 12 12 24 No. of 7/16" hole sets, 1" spacing 3 3 3 6 6 Can Be Clearly Std. Identified with PANDUIT Pkg. Laser/Ink Jet Label* Qty. 1 1 1 1 1

Introduction

Meets BICSI and J-STD-607-A requirements for network systems grounding applications Made of high conductivity copper and tin plated to inhibit corrosion

Part Number
GB2B0304TPI-1 GB2B0306TPI-1

Bar Size 1/4" x 2" x 10" 1/4" x 2" x 12" 1/4" x 2" x 20" 1/4" x 4" x 12" 1/4" x 4" x 20"

Grounding Roadmaps

Telecommunications Grounding Busbars (TGB)


C200X100FJJ

TGB

GB2B0312TPI-1 GB4B0612TPI-1 GB4B0624TPI-1

Telecommunications Main Grounding Busbars (TMGB)


C200X100FJJ
Equipment & Rack Grounding Kits

TMGB

For additional label sizes, materials and print technologies and to see the complete line of PANDUIT identification products, see the Identification Solutions Catalog SA-IDCB16. *Busbar labels sold separately.

C200X100FJJ

Common Bonding Network (CBN) Components

Telecommunications Grounding and Bonding Conductor Label Kit


Meets labeling requirements of J-STD-607-A; each Kit includes everything needed to properly label cables; one telecommunications grounding and bonding conductor shall flame retardant cable tie and one rigid plastic yellow tag be labeled as close as practicable to its point of termination in printed with IF THIS CONNECTOR OR CABLE IS LOOSE a readable position OR MUST BE REMOVED, PLEASE CALL THE BUILDING Can be applied as a wrap-around marker (parallel to cable) or TELECOMMUNICATIONS MANAGER flag marker (45 or 90) to cable
Std. Pkg. Qty. 10
Crimping Tools

Part Number
LTYK

Part Description Label kit includes printed tag and one flame retardant cable tie

Technical Information

For additional label sizes, materials and print technologies and to see the complete line of PANDUIT identification products, see the Identification Solutions Catalog SA-IDCB16.

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

15

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Ring Terminal, Vinyl Expanded Insulation
Introduction

Expanded wire entry allows for large O.D. wire insulation or multiple wire crimps within one wire barrel Industry standard color coding to indicate wire range

Brazed seam assures a reliable crimp Insulation support Requires crimping tools, see page 24
Figure Stud Dimensions (In.) Size L W C #6 .96 .31 .25 #8 .96 .31 .25 #10 .96 .31 .25 1/4" 1.16 .46 .37 #6 #8 #10 1/4" 1.10 1.10 1.10 1.29 .31 .31 .31 .52 .30 .30 .30 .39

Part Number
PV14-6RX-C Grounding Roadmaps PV14-8RX-C PV14-10RX-C PV14-14RX-C PV10-6RX-L PV10-8RX-L PV10-14RX-L
L

Wire Color Stock Range Code Thickness .03 .03 16-14 Blue AWG .03 .03 12-10 .04 .04 .04 .04

Max. Ins. .200 .200 .200 .200 .250 .250 .250 .250

PANDUIT Crimping Tool


CT-100, CT-1550

Std. Pkg. Qty.** 100 100 100 100 50 50 50 50

Std. Ctn. Qty. 500 500 500 500 500 500 500 500

PV10-10RX-L AWG

Yellow

CT-100, CT-1550

Equipment & Rack Grounding Kits


C

For additional sizes and configurations and to see the complete line of PAN-TERM Terminals, see the Termination Solutions Catalog SA-TMCB02. UL and CSA approved tooling/product combinations. For crimping tools see page 24. **To order in bulk, replace -C in the part number with -M for a bulk package of 1000 and replace -L with -D for a bulk package of 500.

Common Bonding Network (CBN) Components

Code Conductor, Two-Hole, Long Barrel with Window Lug


For Use with Stranded Copper Conductors
Crimping Tools

Technical Information

Meets J-STD-607-A requirements for network systems grounding applications Tested by Telcordia meets NEBS Level 3 Requires crimping tools and dies, see pages 24, 25, 26 and 27 UL Listed for use up to 35KV**, temperature rated 90C and CSA Certified to 600V when crimped with PANDUIT and specified competitor crimping tools and dies UL Listed and CSA Certified for wire range-taking capability when crimped with PANDUIT UNI-DIE dieless crimping tools

Color coded barrels marked with PANDUIT and specified competitor die index numbers for proper crimp die selection Long barrel maximizes number of crimps and provides premium wire pull-out strength and electrical performance Inspection window to visually assure full conductor insertion Tin plated to inhibit corrosion Available with NEMA hole sizes and spacing

Index

16

G ROUND GSystem DataFOR Center S TRUCTURED S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Code Conductor, Two-Hole, Long Barrel with Window Lug (continued)
W
HOLE SPACING

W
HOLE SPACING

W
HOLE SPACING

Introduction
W
HOLE SPACING INSPECTION WINDOW

L B
INSPECTION WINDOW

L
INSPECTION WINDOW

B
INSPECTION WINDOW

T
90

T T

45

L
B

Grounding Roadmaps
L

Figure 1

Figure 2: Slotted Lug

Figure 3: Slotted Lug 45Bent

Figure 4: Slotted Lug 90Bent

Stud Stud Hole Hole Copper Figure Conductor Size Spacing (In.) (In.) Part Number No. Size LCC10-14JAW-L* 2 1/4 .50 .63 #14 #10 LCC10-14JAWH-L* 3 AWG STR, 1/4 .50 .63 LCC10-14JAWF-L* #12 #10 1/4 .50 .63 4 AWG SOL 1/4 LCC10-14BW-L* 1 .75
LCC8-10ABW-L LCC8-14ABW-L LCC8-14DW-L LCC8-38DW-L LCC6-10ABW-L LCC6-14JAW-L LCC6-14JAWH-L LCC6-14JAWF-L LCC6-14BDW-L LCC6-14EW-L LCC6-56BW-L LCC6-38BDW-L LCC4-14ADW-L LCC4-38DW-L LCC2-14AW-Q LCC2-38DW-Q LCC1-14AW-E LCC1-38DW-E LCC1/0-14AW-X LCC1/0-38DW-X LCC2/0-14AW-X LCC2/0-38DW-X LCC3/0-38DW-X LCC3/0-12W-X LCC4/0-14AW-X LCC4/0-38DW-X LCC250-38DW-X LCC250-12DW-X

Figure Dimensions (In.) W .42 .42 .42 .42 .41 .48 .48 .60 .46 .48 .48 .48 .48 .48 .56 .62 .55 .62 .60 .66 .70 .70 .76 .76 .85 .85 .96 .96 B .53 .53 .53 .53 .70 .70 .70 .70 T L .05 1.93 .05 1.78 .05 1.56 .05 2.06 .08 2.14 .07 2.23 .07 2.48 .05 2.70

PANDUIT Crimping Tool


CT-100, CT-1570

PANDUIT Die Color & Die No.


Red P21

Burndy T&B Die Die No. No. 49 49 49 49 7 7 7 7 7 7 7 7 8 8 10 10 11 11 12 12 13 13 14 14 15 15 16 16 21 21 21 21 24 24 24 24 24 24 24 24 29 29 33 33 37 37 42 42 45 45 50 50 54 54 62 62

Wire Strip Std. Length Pkg. (In.) Qty. 9/16 50 9/16 9/16 9/16 3/4 3/4 3/4 3/4 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/4 1 1/4 1 7/16 1 7/16 1 1/2 1 1/2 1 9/16 1 9/16 1 9/16 1 9/16 1 5/8 1 5/8 1 11/16 1 11/16 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 25 25 20 20 10 10 10 10 10 10 10 10 10 10

Equipment & Rack Grounding Kits

2 2 1 1 2 2 3 4 2 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 250 kcmil 4/0 AWG 3/0 AWG 2/0 AWG 1/0 AWG #1 AWG #2 AWG #4 #3 AWG STR #6 AWG #8 AWG

#10 1/4 1/4 3/8 #10 1/4 1/4 1/4 1/4 1/4 5/16 3/8 1/4 3/8 1/4 3/8 1/4 3/8 1/4 3/8 1/4 3/8 3/8 1/2 1/4 3/8 3/8 1/2

.63 .75 .63 .75 1.00 1.00 .63 .75 .50 .63 .50 .63 .50 .63 .75 1.00 1.25 .75 .75 1.00 .63 1.00 1.00 .63 1.00 .63 1.00 .63 1.00 .63 1.00 1.00 1.75 .63 1.00 1.00 1.00

CT-1700, CT-930, CT-2931

Red P21 Red P21 Red P21 Blue P24 Blue P24 Blue P24

1.07 .08 2.52 1.07 .08 2.49 1.07 .08 2.08 1.07 .08 1.66 1.07 .08 2.86 1.07 .08 3.11 1.07 .07 2.73 1.07 .06 3.08 1.05 .09 2.63 1.05 .08 3.09 1.16 .10 2.67 1.16 .10 3.24 1.36 .11 2.89 1.36 .11 3.46 1.44 .12 3.07 1.44 .12 3.57 1.50 .13 3.23 1.50 .13 3.67 1.50 .13 3.70 1.50 .13 4.87 CT-1700, CT-930, CT-2931 CT-1700, CT-930, CT-2931 CT-1700, CT-930, CT-2931 CT-930, CT-2931 CT-930, CT-2931 CT-930, CT-2931 CT-930, CT-2931 CT-930, CT-2931 CT-1700, CT-930, CT-2931

Common Bonding Network (CBN) Components

Blue P24 Blue P24 Blue P24 Blue P24 Blue P24 Gray P29 Gray P29 Brown P33 Brown P33 Green P37 Green P37 Pink P42 Pink P42 Black P45 Black P45 Orange P50 Orange P50 Purple P54 Purple P54 Yellow P62 Yellow P62

Crimping Tools

Technical Information

1.06 1.56 .14 3.35 1.06 1.56 .14 3.81 1.17 1.61 .14 3.89 1.17 1.61 .14 4.12

Index

For additional sizes and configurations and to see the complete line of PAN-LUG Power and Grounding Connectors, see the Termination Solutions Catalog SA-TMCB02. *Not tested to NEBS Level 3 requirements. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000V. For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

17

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Flex Conductor, Two-Hole, Long Barrel with Window Lug
Introduction

For Use with Flexible, Extra-Flexible and Code Stranded Copper Conductors
Meets J-STD-607-A requirements for network systems grounding applications Requires crimping tools and dies, see pages 24, 25, 26 and 27 UL Listed for use up to 35KV**, temperature rated 90C and CSA Certified to 600V when crimped with PANDUIT and specified competitor crimping tools and dies Color coded barrels marked with PANDUIT and specified competitor die index numbers for proper crimp die selection Can be used with code conductor and flex conductor class: G, H, I, K, M and Locomotive Long barrel maximizes number of crimps and provides premium wire pull-out strength and electrical performance Inspection window to visually assure full conductor insertion Generously beveled wire entry prevents bent back strands when inserting conductor into barrel Tin plated to inhibit corrosion Available with NEMA hole sizes and spacing

Grounding Roadmaps

W
HOLE SPACING

W
HOLE SPACING

Equipment & Rack Grounding Kits


T

L B
INSPECTION WINDOW

L
INSPECTION WINDOW

Figure 1

Figure 2: Slotted Lug Figure Dimensions (In.) W .41 .48 .48 .60 .46 .48 .48 .62 .62 .55 .62 .70 B .70 .70 .70 .70 1.07 1.07 1.07 1.07 1.07 1.05 T .08 .07 .07 .05 .08 .08 .08 .06 .06 .09 L 2.14 2.23 2.48 2.70 2.52 2.61 2.86 2.96 3.08 2.63

Common Bonding Network (CBN) Components

Part Number
LCCX8-10AB-L LCCX8-14AB-L LCCX8-14D-L LCCX8-38D-L LCCX6-10B-L LCCX6-14AB-L LCCX6-14D-L LCCX6-38AC-L LCCX6-38D-L LCCX4-14AB-L LCCX4-38BD-L LCCX2-38D-E

Crimping Tools

Flex Conductor Stud Size Code Hole Figure Class Conductor Size No. G, H, I, K, M Locomotive Size (In.) 2 #10 2 1/4 #8 AWG #8 AWG #8 AWG 1 1/4 1 3/8 1 #10 2 1/4 1 1/4 #6 AWG #6 AWG #6 AWG 2 3/8 1 3/8 2 1/4 #5, #4, #3 #4 #3 #4 AWG 2 AWG AWG STR 3/8 1 #2 AWG #2 AWG #2 AWG 3/8

Stud Hole Spacing (In.) .63 .75 .63 .75 1.00 1.00 .75 .63 .75 1.00 .63 .88 1.00 .63 .75 .75 1.00 1.00

1.05 .08 3.09 1.36 .11 3.46

Wire PANDUIT PANDUIT Strip Std. Crimping Die Color Length Pkg. Tool & Die No. (In.) Qty. Red P21 3/4 50 CT-1700, Red P21 3/4 50 CT-930, Red P21 3/4 50 CT-2931 Red P21 3/4 50 Blue P24 1 1/8 50 1 1/8 50 CT-1700, Blue P24 1 1/8 50 CT-930, Blue P24 CT-2931 Blue P24 1 1/8 50 Blue P24 1 1/8 50 Gray P29 1 1/8 50 CT-1700, CT-930, Gray P29 1 1/8 50 CT-2931 CT-1700, Brown 1 7/16 20 CT-930, P33 CT-2931 CT-930, Green P37 1 1/2 CT-2931 Green P37 1 1/2 CT-930, Pink P42 1 9/16 CT-2931 Pink P42 1 9/16 CT-930, Black P45 1 9/16 CT-2931 Black P45 1 9/16 CT-930, Orange 1 5/8 CT-2931 P50 CT-930, Purple 2 5/16 CT-2931 P54 CT-930, Yellow P62 2 5/16 CT-2931 10 10 10 10 10 10 10 10 10

Technical Information

LCCX1-14A-X LCCX1-38D-X LCCX1/0-14A-X LCCX1/0-38D-X LCCX2/0-14A-X LCCX2/0-38D-X LCCX3/0-38D-X LCCX4/0-38D-X LCCX250-38D-X

1 1 1 1 1 1 1 1 1

#1 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG 250 kcmil

#1 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG 262.6 kcmil

#1 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG

1/4 3/8 1/4 3/8 1/4 3/8 3/8 3/8 3/8

.63 1.00 .63 1.00 .63 1.00 1.00 1.00 1.00

.76 .76 .85 .85 .96 .96 1.06

1.44 1.44 1.50 1.50 1.50 1.50 1.56

.12 .12 .13 .13 .13 .13 .14

3.07 3.57 3.23 3.67 3.27 3.70 3.81

1.19 2.24 .16 4.55 1.28 2.24 .17 4.59

Index

For additional sizes and configurations and to see the complete line of PAN-LUG Power and Grounding Connectors, see the Termination Solutions Catalog SA-TMCB02. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000V.

18

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Code/Flex Conductor HTAP Kit


Includes all components to make a complete HTAP and cover installation: HTCT HTAP, matching CLRCVR clear cover and cable ties Each HTCT HTAP designed to terminate a wide range of copper code and flex conductor combinations to accommodate a variety of applications HTAPs incorporate a unique slotted design that allows for quick and easy installation using supplied PANDUIT cable ties; saves time and cost Matching clear covers are made from high impact plastic and provide high impact strength and 360 viewing of installed HTAP Clear covers have a UL 94 V-0 flame rating and an oxygen index of 28 providing self-extinguishing, flame retardant properties Requires crimping tools and dies, see pages 25, 26 and 27 UL Listed and CSA Certified for applications up to 600V when crimped with PANDUIT and specified competitor
Introduction

Grounding Roadmaps

Equipment & Rack Grounding Kits


W W RUN L H H RUN L W RUN L RUN W L

TAP 1

TAP 2 TAP 1

TAP 3

TAP 1

TAP 2

TAP 1

HTCT6-6

HTCT2-2 Components Clear HTAP Cover Part No. Part No. HTCT6-6-1 CLRCVR1-1 HTCT2-2-1 CLRCVR2-1

HTCT250-2 Copper Conductor Size Range Wire Strand Type Code Flex Code Flex

HTCT250-250

Common Bonding Network (CBN) Components

Part Number
HTWC6-6-1 HTWC2-2-1

HTWC250-2-1

HTCT250-2-1

CLRCVR3-1

Code Flex

HTWC250-250-1

HTCT250-250-1 CLRCVR3-1

Code Flex

Run #6 #10 AWG #6 #10 AWG #2 #6 AWG STR/SOL #2 #8 AWG 250 kcmil #2 AWG 4/0 #2 AWG 250 kcmil #2 AWG 4/0 #2 AWG

Tap1 #6 #14 AWG #6 #14 AWG #2 #6 AWG STR/SOL #2 #8 AWG #2 #6 AWG STR/SOL #2 #8 AWG 250 kcmil #2 AWG 4/0 #2 AWG

Tap 2 #8 #14 AWG #8 #14 AWG #8 #14 AWG #8 #14 AWG

Tap 3 #8 #14 AWG #8 #14 AWG

Std. Pkg. Qty. 1


Crimping Tools

1 1

For additional sizes and configurations and to see the complete line of PAN-LUG Power and Grounding Connectors, see the Termination Solutions Catalog SA-TMCB02. See pages 20 and 21 for more information on HTAPs and clear covers, including crimping tools. Labels for clear covers are sold separately and are printed with the PANDUIT LS7 Printer. For information on the LS7 Printer and to see the complete line of PANDUIT identification products, see the Identification Solutions Catalog SA-IDCB16.

Technical Information

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

19

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Code/Flex Conductor HTAP
Introduction

For Making Parallel and Multiple Tap Connections on Code and Flex Conductors
Used to tap into continuous conductors as a splice or pigtailing Each HTAP terminates a wide range of conductor sizes and combinations of code and flex conductors Class G, H, I and Locomotive to suit a variety of applications Slotted design allows quick and easy assembly of conductor to HTAP using 3 PANDUIT 94 V-0 cable ties included
HTAP RUN

Grounding Roadmaps

TAP

Tap grooves are separated from one another allowing them to function independently so HTAP can be used with a single or multiple taps providing maximum design and installation flexibility Color coded and marked with PANDUIT die index numbers for proper crimp die selection Requires crimping tools and dies, see pages 25, 26 and 27 UL Listed and CSA Certified for applications up to 600V when crimped with PANDUIT and specified competitor crimping tools and PANDUIT crimping dies Tin plated to inhibit corrosion

Equipment & Rack Grounding Kits

W W RUN L H RUN L

W RUN

RUN

TAP 1

TAP 2 TAP 1

TAP 3

TAP 1

TAP 2

TAP 1

Common Bonding Network (CBN) Components

HTCT6-6

HTCT2-2

HTCT250-2 Figure Dimensions (In.)

HTCT250-250

Copper Conductor Size Range Wire Strand Type Code Flex


HTCT2-2-1

Part Number
HTCT6-6-1

Run #6 #10 AWG #6 #10 AWG #2 #6 AWG STR/SOL #2 #8 AWG

Tap 1 #6 #14 AWG #6 #14 AWG

Tap 2

Tap 3

L .61

W .40

H .99

PANDUIT Crimping Tool CT-930, CT-2931

Wire PANDUIT Strip Std. Die Color Length Pkg. & Die No. (In.) Qty. Orange, 11/16 1 PH6

#8 #14 AWG #8 #14 AWG .92 .90 .89 1.92 CT-930, CT-2931 Purple, PH25 1 1 .96 1.92 CT-930, CT-2931 Purple, PH25 1 1 .76 .61 1.55 CT-930, CT-2931 Brown, PH2 13/16 1

Crimping Tools

Code Flex
HTCT250-2-1

#2 #6 AWG #8 #14 STR/SOL AWG #2 #8 AWG #8 #14 AWG

Code Flex

250 kcmil #2 #6 AWG #8 #14 #2 AWG STR/SOL AWG 4/0 #2 AWG 250 kcmil #2 AWG 4/0 #2 AWG #2 #8 AWG #8 #14 AWG 250 kcmil #2 AWG 4/0 #2 AWG

Technical Information

HTCT250-250-1

Code Flex

For additional sizes and configurations and to see the complete line of PAN-LUG Power and Grounding Connectors, see the Termination Solutions Catalog SA-TMCB02.

Index

20

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Clear Covers for HTCT HTAPs


For Use with PANDUIT HTCT HTAPs
Made of high impact plastic to provide high impact strength and 360 inspections of crimped connection to assure the crimp is complete and the correct die was used Incorporate dual self-latching spring loaded latches and supplied with two PANDUIT UL 94 V-0 cable ties allow for easy snap-on assembly and ensure covers are secured Low profile design minimizes space requirements Each cover half supports installation information labels inside plastic retainer strips to allow labels to be viewed on either side of cover and to protect labels from being removed Incorporate molded in flash barriers which encompass the HTAP installation providing protection against electrical flash over UL 94 V-0 flame rating and oxygen index of 28 providing self-extinguishing, flame retardant properties Part number, voltage rating, temperature rating and HTCT part number molded into cover for easy identification Flexible fingers located at each end of cover prevent foreign objects from entering cover and are made from ductile plastic material that allows easy installation and will not damage conductor insulation
Figure Dimensions Std. (In.) Pkg. Qty. L W H 4.48 1.41 1.20 1 5.10 1.66 1.40 1 5.35 2.16 1.40 1
Introduction

Grounding Roadmaps

Part Number
CLRCVR1-1 CLRCVR2-1 CLRCVR3-1

Use With HTAP Part Number HTCT6-6 HTCT2-2 HTCT250-2, HTCT250-250

Equipment & Rack Grounding Kits

For additional sizes and configurations and to see the complete line of PAN-LUG Power and Grounding Connectors, see the Termination Solutions Catalog SA-TMCB02. Labels for clear covers are sold separately and are printed with the PANDUIT LS7 Printer. For information on the LS7 Printer and to see the complete line of PANDUIT identification products, see the Identification Solutions Catalog SA-IDCB16.

Shown Assembled

Common Bonding Network (CBN) Components

Crimping Tools

Technical Information

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

21

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


C

UL
R

US

Grounding Clamp, U-Bolt, Bronze


Accommodates a wide range of pipe, tube, rod and conductor sizes minimizes inventory UL Listed for grounding and bonding and suitable for direct burial in earth or concrete

Introduction

Used to ground copper conductor parallel or at a right angle to a rod, tube or pipe Made from high strength, electrolytic cast bronze High strength silicon bronze hardware provides long term reliable assembly

Grounding Roadmaps

W Ground Rod Size (In.) 7/8 or 1 Iron Pipe Size (In.) 1/2 or 3/4 1 1

L Figure Dimensions (In.) L W H 2.38 1.38 2.63 2.63 1.38 2.75 2.63 1.63 2.75 Bolt Dia. (In.) 3/8 3/8 3/8 Hex Size (In.) 9/16 9/16 9/16 Tightening Std. Torque Pkg. (In.-Lbs.) Qty. 110 25 110 10 180 10

Part Number
GPL-8-Q Equipment & Rack Grounding Kits GPL-14-X GPL-15-X

Conductor Size Range #8 SOL #4 STR #8 SOL #4 STR #4 SOL 2/0 STR

For the complete line of PAN-LUG Power and Grounding Connectors, see the Termination Solutions Catalog SA-TMCB02.

Common Bonding Network (CBN) Components

Crimping Tools

Technical Information

Index

22

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Grounding Clamp for Water Pipes, Bronze


Used to ground copper code conductor to water pipe or copper tube Cast from high strength, electrolytic bronze to provide reliable grounding connections Plated steel screws provide high strength and inhibit corrosion Accommodates a wide range of pipe, tube, rod and conductor sizes minimizes inventory UL Listed for grounding and bonding and suitable for direct burial in earth or concrete
Introduction

Part Number
KP1-C KP2-L

Figure Tightening Torque Water Pipe Dimensions (In.) (In.-Lbs.) Range Conductor (In.) Size Range L W Conductor Clamp 1/2 1 #10 SOL #2 STR 2.28 .66 50 50 1 1/4 2 #10 SOL #2 STR 3.58 .73 50 50

Std. Pkg. Qty. 100 50

Grounding Roadmaps

For the complete line of PAN-LUG Power and Grounding Connectors, see the Termination Solutions Catalog SA-TMCB02.

W
Equipment & Rack Grounding Kits

Grounding Rod Clamp, Bronze


Used for grounding copper conductor parallel to ground rods Made from high strength, seamless electrolytic bronze to provide long term durability High strength silicon bronze hardware provides long term reliable assembly
Ground Rod Size 1/2 5/8 3/4 5/8

Accommodates a wide range of rod and conductor sizes minimizes inventory UL Listed and CSA Certified for grounding and bonding and suitable for direct burial in earth and concrete

Common Bonding Network (CBN) Components

Part Number
WB12-L WB34-X WB58-Q

Conductor Size Range #2 #10 STR #10 SOL 1/0 #8 STR #2 #8 STR 1/0 #8 STR

Figure Dimensions (In.) L W H .88 .84 1.28 1.03 1.04 1.06 .92 1.54 1.40

Hex Tightening Std. Size Torque Pkg. (In.) (In.-Lbs.) Qty. 1/2 180 50 1/2 1/2 180 180 10 25

Crimping Tools

For the complete line of PAN-LUG Power and Grounding Connectors, see the Termination Solutions Catalog SA-TMCB02.

Technical Information

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

23

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Crimping Tools
Introduction

Hand Operated Plier Type Tool


Plier type Installer controlled crimp
Std. Pkg. Qty. 1

Part Number
Grounding Roadmaps CT-100

Part Description Crimps most PANDUIT #26 #10 AWG insulated and non-insulated terminals, disconnects and splices. Cuts #4, #6, #8 and #10 screw sizes. Cuts and strips wire. Excellent all-around application tool of heat treated finished steel with comfortable cushioned plastic grip handles.

For the complete line of PANDUIT crimping tools and dies, see the Termination Solutions Catalog SA-TMCB02.

Equipment & Rack Grounding Kits

CONTOUR CRIMP Controlled Cycle Tools


Specifically designed for the installation of PAN-TERM terminals, disconnects and splices Low handle effort increases productivity Superior crimp performance Reliable backed by a two year warranty

Common Bonding Network (CBN) Components

Part Number
CT-1550

CT-1550
CT-1570

Part Description Crimps most PAN-TERM #22 #10 AWG nylon and vinyl insulated terminals, splices and disconnects. The CT-1550 has the red/blue pocket closest to the pivot which provides a reduced crimp effort for those who make red/blue terminations. Crimps most PAN-TERM #22 #10 AWG and .5-6.0mm non-insulated terminals and disconnects. Crimps PANDUIT #22 #10 AWG and .5-6.0mm non-insulated splices, and #10 AWG compression lugs. Crimps PANDUIT #8 #2 AWG non-insulated tubular terminals (S series), #8 #1 AWG copper lugs and splices, #6 #4 AWG aluminum lugs and splices and CTAPF copper taps for #14 #3 AWG. Includes 5 position, color coded rotating die.

Std. Pkg. Qty. 1

Crimping Tools

CT-1700

CT-1570

For the complete line of PANDUIT crimping tools and dies, see the Termination Solutions Catalog SA-TMCB02.

CT- 1700
Technical Information

Index

24

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Die Type, Manual Hydraulic, 14 Ton, Crimping Tool


Two-stage rapid advance hydraulic system minimizes number of pumps required to complete a crimp saves time Cushioned grip prevents hands from slipping on tool reduces fatigue Provides UL Listed and CSA Certified connections on PANDUIT PAN-LUG copper and aluminum lugs and splices and copper taps Open C-Head design allows easy loading of crimping dies and connectors, saves time Requires crimping dies, see page 27 Dies installed using spring loaded die retention pins, no need for tools Rubber boot on crimp head provides abrasion protection Audible pop-off valve indicates crimp completion Crimp head rotates 180, provides versatility for use in restricted spaces
Introduction

Grounding Roadmaps

Part Number
CT-930

Part Description Terminates PANDUIT PAN-LUG Compression Connectors: Copper compression lugs and splices for #8 AWG 750 kcmil code conductor Copper compression lugs and splices for #8 AWG 600 kcmil flex conductor Copper compression CTAPF taps for #10 AWG 3/0 AWG code conductor Copper compression CTAP taps for #8 AWG 4/0 AWG code conductor Copper compression HTCT taps for #14 AWG 250 kcmil code conductor, #14 AWG 4/0 AWG flex conductor Aluminum compression lugs and splices for #6 AWG 600 kcmil code conductor Aluminum compression HTAPS for #14 AWG 500 kcmil code conductor PANDUIT PAN-TERM Tubular Terminals for #8 AWG 250 kcmil code conductor

Std. Pkg. Qty. 1

Equipment & Rack Grounding Kits

Warranty: 5 years CT-930 includes: Tool Plastic tool case with die storage
For the complete line of PANDUIT crimping tools and dies, see the Termination Solutions Catalog SA-TMCB02. CG-920 crimp force measurement gauge available, sold separately, see the Termination Solutions Catalog SA-TMCB02.

Common Bonding Network (CBN) Components

Crimping Tools

Technical Information

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

25

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Die Type, Battery Powered Hydraulic, 12 Ton, Crimping Tool
Introduction

Two stage rapid advance hydraulic system minimizes cycle time Provides UL Listed and CSA Certified connections on PANDUIT PAN-LUG copper and aluminum lugs and splices and copper taps Open C-Head design allows easy loading of crimping dies and connectors, saves time Rubber boot on crimp head provides abrasion protection Ram automatically retracts when crimp cycle is complete

Grounding Roadmaps

Tool provided with two, high capacity 12 VDC rechargeable nickel-metal hydride batteries provides for continuous operation and eliminates memory build-up, one hour charge time Eight second crimp cycle time provides quick terminations, saves time Uses industry standard Makita* batteries and charger industry proven reliability easy to obtain from local retail sources Requires crimping dies, see page 27 Dies installed using spring loaded die retention pins no need for tools Crimp head rotates 360 provides versatility for use in restricted spaces

Equipment & Rack Grounding Kits

Part Number
CT-2931

Part Description Terminates PANDUIT PAN-LUG Compression Connectors: Copper compression lugs and splices for #8 AWG 750 kcmil code conductor Copper compression lugs and splices for #8 AWG 600 kcmil flex conductor Copper compression CTAPF taps for #10 AWG 3/0 AWG code conductor Copper compression CTAP taps for #8 AWG 4/0 AWG code conductor Copper compression HTCT taps for #14 AWG 250 kcmil code conductor, #14 AWG 4/0 AWG flex conductor Aluminum compression lugs and splices for #6 AWG 600 kcmil code conductor Aluminum compression HTAPS for #14 AWG 500 kcmil code conductor PANDUIT PAN-TERM Tubular Terminals for #8 AWG 250 kcmil code conductor

Std. Pkg. Qty. 1

Common Bonding Network (CBN) Components

Warranty: 3 years CT-2931 includes: Tool Two 12 VDC, rechargeable NiMH batteries One battery charger Steel tool case with storage for batteries, charger and crimp dies
For the complete line of PANDUIT crimping tools and dies, see the Termination Solutions Catalog SA-TMCB02. CG-920 crimp force measurement gauge available, sold separately, see the Termination Solutions Catalog SA-TMCB02. *Makita is a registered trademark of Makita Corporation.

Crimping Tools

Technical Information

Index

26

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

CD-920 Crimping Dies


Crimping dies and connectors are color coded for easy matching Embosses die index number on connector barrels for post crimp inspection
Die Color

Part number permanently marked on crimping die for easy identification Provides circumferential crimp results in terminations with premium electrical and mechanical performance Used in PANDUIT crimping tools; see the CT-930 crimping tool on page 25, the CT-2931 crimping tool on page 26 and the complete line of PANDUIT crimping tools in the Termination Solutions Catalog SA-TMCB02

Introduction

Grounding Roadmaps

Die Number

Used to Install PANDUIT Compression Lug & Splice Sizes Part Number
CD-920-8 CD-920-6 CD-920-4 CD-920-2 CD-920-1 CD-920-1/0 CD-920-2/0 CD-920-3/0 CD-920-4/0 CD-920-250

CD-920

Copper Code Conductor Size and Die Color & Die No. #8 AWG, Red P21 #6 AWG, Blue P24 #4 AWG, Gray P29 #2 AWG, Brown P33 #1 AWG, Green P37 1/0 AWG, Pink P42 2/0 AWG, Black P45 3/0 AWG, Orange P50 4/0 AWG, Purple P54 250 kcmil, Yellow P62

Std. Pkg. Qty. 1 1 1 1 1 1 1 1 1 1

Equipment & Rack Grounding Kits

Common Bonding Network (CBN) Components

Used to Install PANDUIT HTAP Part Numbers Part Number


CD-920H-6 CD-920H-2 CD-930H-250

Copper HTAP and Die Color & Die No. HTCT6-6-1, Orange PH6 HTCT2-2-1, Brown PH2 HTCT250-2-1, HTCT250-250-1, Purple PH25

Std. Pkg. Qty. 1 1 1

Crimping Tools

For the complete line of PANDUIT crimping tools and dies, see the Termination Solutions Catalog SA-TMCB02.

Technical Information

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

27

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


PANDUIT STRUCTUREDGROUND System for Data Center Grounding Application Standards
Alliance for Telecommunications Industry Solutions ATIS ATIS is a technical planning and standards development organization that is committed to rapidly developing and promoting technical and operations standards for the communications and related information technologies industry worldwide using a pragmatic, flexible and open approach. Over 1,200 participants from more than 400 communications companies are active in ATIS 22 industry committees, and its Incubator Solutions Program. www.atis.org J-STD-607-A-2002, Commercial Building Grounding (Earthing) and Bonding Requirements for Telecommunications is jointly developed by TIA/EIA and ATIS technical committee T1E1. This document is available on the ATIS Document Center at www.atis.org. Adhering to the grounding principles outlined in J-STD-607-A helps ensure that telecommunications equipment and systems operate reliably. As stated in J-STD-607-A, the preferred means of connecting conductors to busbars is by using two-hole irreversible compression lugs listed by a nationally recognized testing laboratory (NRTL) such as UL. PANDUIT PAN-LUG Copper Compression Connectors meet these requirements, in all of the barrel sizes specified by the 607 standard. ANSI/TIA-942 Draft 5.0a Telecommunications Infrastructure Standard for Data Centers TIA-942 states that electrical continuity is required throughout the rack materials. Adhering to these principles protects network equipment and maintains system performance. PANDUIT STRUCTUREDGROUND System for Data Center Grounding meets TIA-942 requirements by incorporating an all-copper grounding path. Paint piercing grounding washers ensure metal to metal contact of rack members and two-hole compression lugs for a permanent and reliable connection. IEEE Std 1100-1999 (IEEE Emerald Book) IEEE Recommended Practice for Powering and Grounding Electronic Equipment The main objective of the Emerald Book is to provide a consensus of recommended practices to address electronic equipment performance issues while maintaining a safe installation, as specified in the National Electrical Code (NEC ) (NFPA 70-1999) and recognized testing laboratories' standards. NEBS Level 3 Criteria is the minimum level of environmental compatibility needed to provide maximum assurance of equipment operability within the network facility environment. The Level 3 Criteria is the highest assurance of product operability. Products that meet NEBS Level 3 Criteria are suited for equipment applications which demand minimal service interruptions over the life span of the equipment. PANDUIT is the first in the industry to have a system of copper compression lugs and splices (#8 AWG 1,000 kcmil) and crimping tools physically and rigorously tested by Telcordia Technologies to meet NEBS Level 3 compliance. UL 467 Grounding and Bonding Equipment UL 486A Wire Connectors and Soldering Lugs for Use with Copper Conductors Covers pressure wire connectors and soldering lugs for use with copper conductors according to the National Electrical Code NFPA 70 UL VW-1 Flammability Rating Underwriters Laboratories, Inc. Standards applicable to specified PANDUIT STRUCTUREDGROUND System for Data Center Grounding and PAN-LUG Power and Grounding Connectors. Canadian Standards Association
Index

Introduction

Grounding Roadmaps

Telecommunications Industry Association TIA The Telecommunications Industry Association is a leading U.S. non-profit trade association serving the communications and information technology industry. TIA represents providers of communications and information technology products and services for the global marketplace through its core competencies in standards development.

Equipment & Rack Grounding Kits

The Institute of Electrical and Electronics Engineers, Inc. (IEEE)


Common Bonding Network (CBN) Components

The IEEE developing, electro and of humanity

promotes the engineering process of creating, integrating, sharing, and applying knowledge about information technologies and sciences for the benefit and the profession.

NEBS Level 3 Approval as Tested by Telcordia Technologies Telcordia Technologies, formerly known as Bellcore, serves as the testing agency for the Regional Bell Operating Companies. Network Equipment-Building Systems (NEBS) was developed by Bellcore and is currently maintained by Telcordia Technologies. NEBS was developed to standardize requirements for Central Office Equipment and to develop criteria for personal safety, protection of property and operational continuity.

Crimping Tools

Underwriters Laboratories, Inc.


Technical Information

Underwriters Laboratories, Inc. is an independent, not-for-profit safety testing and certification organization based in the United States.

Canadian Standards Association is a not-for-profit membership based association serving business, industry, government, and consumers in Canada and the global marketplace. C.S.A. works in Canada and around the world to develop standards that enhance public safety and health.

C22.2 NO. 41-M1987 (R2004) Grounding and Bonding Equipment C22.2 NO. 65-03 Wire Connectors Canadian Standards Association standards that are applicable to specified PANDUIT STRUCTUREDGROUND System for Data Center Grounding and PAN-LUG Power and Grounding Connectors.

28

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Specification Layout for Data Center Grounding per BICSI TDM Manual, 10th Edition
Introduction

Roof
Red iron Backbone pathway

Suspended ceiling area


Building steel

GE
Building steel

TR

TR

GE

Grounding Roadmaps

TGB

TGB

Red iron Exterior building wall Backbone pathway

Equipment & Rack Grounding Kits

Suspended ceiling area TR TR (TBB)


Exterior building wall

TBB TGB TGB

Common Bonding Network (CBN) Components

Sleeve

Red iron Backbone pathway

Suspended ceiling area


(TBB)

EF Primary cable protection

TBB within conduit

ER (TBB) Panel board


Crimping Tools

ACEG

Electrical EF GEC

TMGB

TGB

BCT Grounding electrode system ACEG BC BCT EF ER GE GEC TBB TGB TMGB TR

Source: BICSI TDM Manual, 10th Edition


= = = = = = = = = = = Alternating current equipment ground Bonding conductor Bonding conductor for telecommunications Entrance facility Equipment room Grounding equalizer Grounding electrode conductor Telecommunications bonding backbone Telecommunications grounding busbar Telecommunications main grounding busbar Telecommunications room

Technical Information

Index

For more technical grounding information, please see the Data Center Grounding White Paper at www.panduit.com/dcgrounding. For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

29

S TRUCTURED G ROUND SYSTEM FOR DATA CENTER GROUNDING


Recommended Sizing of the Telecommunications Bonding Backbone (TBB) and Grounding Equalizer (GE) per J-STD-607-A
Introduction

The TBB shall be a copper conductor. The minimum conductor size shall be a No. 6 AWG. The TBB shall be sized at 2 kcmil per linear foot of conductor length up to a maximum size of a 3/0 AWG. The TBB may be insulated. The Bonding conductor for Telecommunications (BCT) shall be, as a minimum, the same size as the TBB.(1)
Sizing of the TBB TBB Length linear M (ft) less than 4 (13) 4 6 (14 20) 6 8 (21 26) 8 10 (27 33)
Equipment & Rack Grounding Kits

Grounding Roadmaps

TBB Size (AWG) 6 4 3 2 1 1/0 2/0 3/0*

10 13 (34 41) 13 16 (42 52) 16 20 (53 66) greater than 20 (66)

*3/0 may not always be available. 4/0 is a more common size that may be substituted.

Common Bonding Network (CBN) Components

Recommended Cable Sizes for Grounding Applications


Purpose
Other connections to the TGB and TMGB, including building steel, main water pipe, etc. Underfloor CBN Connections to Underfloor CBN from pipes, ventilation ducts, etc. Connection from Underfloor CBN to TGB

Use the Following Code Cables #6 AWG, green insulated #2 AWG, bare #6 AWG, bare 2/0 AWG, bare

Crimping Tools

Key Terminology
Ground A conducting connection, whether intentional or accidental, by which an electric circuit or equipment is connected to the earth, or to some conducting body of relatively large extent that serves in place of the earth. The permanent joining of metallic parts to form an electrically conductive path that will assure electrical continuity and the capacity to conduct safely any current likely to be imposed. The principal means for affecting bonding and earthing inside a building.

Technical Information

Bonding

Common Bonding Network (CBN)


Index

1. Telecommunications Industry Association, Commercial Building Grounding (Earthing) and Bonding Requirements For Telecommunications, J-STD-607-A, October 2002.

30

S TRUCTURED G ROUND GSystem DataFOR Center S TRUCTURED ROUND for SYSTEM DATA Grounding CENTER GROUNDING
Introduction

Part Number Index


Introduction
Part Number Page Number Part Number Page Number Part Number Page Number

C
CD-920-1 . . . CD-920-1/0 . . CD-920-2 . . . CD-920-2/0 . . CD-920-250 . CD-920-3/0 . . CD-920-4 . . . CD-920-4/0 . . CD-920-6 . . . CD-920-8 . . . CD-920H-2 . . CD-920H-6 . . CD-930H-250 CLRCVR1-1 . CLRCVR2-1 . CLRCVR3-1 . CT-100 . . . . . CT-1550 . . . . CT-1570 . . . . CT-1700 . . . . CT-2931 . . . . CT-930 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 .27 .27 .27 .27 .27 .27 .27 .27 .27 .27 .27 .27 .21 .21 .21 .24 .24 .24 .24 .26 .25 LCC1-14AW-E . . . LCC1-38DW-E . . LCC1/0-14AW-X . LCC1/0-38DW-X . LCC10-14BW-L . . LCC10-14JAW-L LCC10-14JAWF-L LCC10-14JAWH-L LCC2-14AW-Q . . LCC2-38DW-Q . . LCC2/0-14AW-X . LCC2/0-38DW-X . LCC250-12DW-X . LCC250-38DW-X . LCC3/0-12W-X . . LCC3/0-38DW-X . LCC4-14ADW-L . . LCC4-38DW-L . . . LCC4/0-14AW-X . LCC4/0-38DW-X . LCC6-10ABW-L . . LCC6-14BDW-L . . LCC6-14EW-L . . . LCC6-14JAW-L . . LCC6-14JAWF-L . LCC6-14JAWH-L . LCC6-38BDW-L . . LCC6-56BW-L . . . LCC8-10ABW-L . . LCC8-14ABW-L . . LCC8-14DW-L . . . LCC8-38DW-L . . . LCCX1-14A-X . . . LCCX1-38D-X . . . LCCX1/0-14A-X . LCCX1/0-38D-X . LCCX2-38D-E . . . LCCX2/0-14A-X . LCCX2/0-38D-X . LCCX250-38D-X . LCCX3/0-38D-X . LCCX4-14AB-L . . LCCX4-38BD-L . . LCCX4/0-38D-X . LCCX6-10B-L . . . LCCX6-14AB-L . . LCCX6-14D-L . . . LCCX6-38AC-L . . LCCX6-38D-L . . . LCCX8-10AB-L . . LCCX8-14AB-L . . LCCX8-14D-L . . . LCCX8-38D-L . . . LTYK . . . . . . . . . .

L
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .18 .15 PV10-10RX-L PV10-14RX-L PV10-6RX-L . PV10-8RX-L . PV14-10RX-C PV14-14RX-C PV14-6RX-C . PV14-8RX-C . . . . . . . . . . . . . . . . . . . . . . . . .

P
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 .16 .16 .16 .16 .16 .16 .16

Grounding Roadmaps

R
RGCBNJ660P . RGEJ1024PF . RGEJ1024PH . RGEJ1036PF . RGEJ1057PF . RGEJ624PF . . RGEJ624PH . . RGEJ636PF . . RGEJ657PF . . RGESD-1 . . . . RGRB19 . . . . . RGREJ1096 . . RGREJ696 . . . RGRKCBNJ . . RGRKCBNJEJ RGS134-1 . . . . RGS134-10-1 . RGTBS-C . . . . RGTBSM6-C . . RGTS-C . . . . . RGTSM6-C . . . RGW-100-1 . . . RGW-12-1 . . . . RGW-32-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 .12 .12 .12 .12 .12 .12 .12 .12 .13 .14 .14 .14 .14 .14 .11 .11 .14 .14 .14 .14 .13 .13 .13
Equipment & Rack Grounding Kits

G
GB2B0304TPI-1 GB2B0306TPI-1 GB2B0312TPI-1 GB4B0612TPI-1 GB4B0624TPI-1 GPL-14-X . . . . . GPL-15-X . . . . . GPL-8-Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 .15 .15 .15 .15 .22 .22 .22

Common Bonding Network (CBN) Components

H
HTCT2-2-1 . . . . HTCT250-2-1 . . HTCT250-250-1 HTCT6-6-1 . . . . HTWC2-2-1 . . . . HTWC250-2-1 . . HTWC250-250-1 HTWC6-6-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 .20 .20 .20 .19 .19 .19 .19

Crimping Tools

W
WB12-L . . . . . . . . . . . . . . . . . . . . . . .23 WB34-X . . . . . . . . . . . . . . . . . . . . . .23 WB58-Q . . . . . . . . . . . . . . . . . . . . . .23

Technical Information

K
KP1-C . . . . . . . . . . . . . . . . . . . . . . .23 KP2-L . . . . . . . . . . . . . . . . . . . . . . . .23

Index

For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).

31

PANDUIT is a global leader in cabling and communication products, delivering end-to-end solutions in support of demanding electrical and networking requirements.

PANDUIT Catalogs
Cable Ties
SA-CTCB03
!PAN-TY Cable Ties !PAN-TY Clamp Ties

Termination Solutions
SA-TMCB02
!PAN-TERM Terminals !PAN-TERM Disconnects !PAN-TERM Splices

!CONTOUR-TY Cable Ties !DURA-TY Cable Ties

!Crimping Tools and Dies !PAN-LUG Mechanical Connectors !PAN-LUG Grounding Connectors !Support Products

!PAN-TY Push Mount Ties !PAN-TY Marker Ties !DOME-TOP Barb Ty Cable Ties !DOME-TOP Barb Ty Clamp Ties !DOME-TOP Barb Ty Marker Ties

!BELT-TY In-Line Cable Ties

!TAK-TY Hook & Loop Cable Ties

!PAN-TERM Ferrules !PAN-LUG Compression

!STA-STRAP Cable Ties !Cable Tie Installation Tools !Custom Hot Stamping

Connectors

Wiring Accessories/Abrasion Protection


SA-CTCB03
!Adhesive Backed Cable Tie !Grommet Edging !Braided Expandable Sleeving !Corrugated Loom Tubing

Stainless Steel Products


SA-SSCB06
!PAN-STEEL Stainless Steel !PAN-STEEL System Accessories !PAN-STEEL System

Mounts !Screw Applied Cable Tie Mounts !Flat Cable Mounts !Fixed Diameter Clamps !Harness Board Accessories !Spiral Wrap

and Fittings !Heat Shrink Tubing !Non-Shrink PVC Tubing !PAN-WRAP Split Harness Wrap

Cable Ties !PAN-STEEL Stainless Steel Strapping !Installation Tools

Permanent Identification

Identification Products
SA-IDCB16
!Hand-Held Printers !Desktop Printers !Labeling Software !Computer Printable Labels !Wire Markers !Lockout/Tagout Products !Voltage Markers !Warning Labels !Safety Signs and Tags !Letters and Numbers

Surface Raceway
SA-SRCB02
!Office Furniture Raceway !Cove Raceway !PAN-WAY TG-70 Surface Raceway

!Faceplates, Surface Mount Outlet

Boxes & Labeling Administration


!PAN-WAY LD Profile Surface

!PAN-WAY T-70 & Twin-70

Raceway
!PAN-WAY T130 Surface Raceway !PAN-POLE Outlet Poles

Surface Raceway !PAN-WAY T-45 Surface Raceway !ULTIMATE ID Network Labeling System

Wiring Duct
SA-WDCB05
!PANDUCT Slotted Wall !PANDUCT Hinged Slotted Wall !Modules

Network Connectivity
SA-NCCB04
!Racks & Cable Management !Grounding and Bonding !Fiber Routing !Surface Raceway !Labeling & Administration !Cable Ties & Accessories

Wiring Duct !PANDUCT Solid Wall Raceway !PANDUCT Halogen Free Slotted Wall Wiring Duct !PANDUCT Flush Cover Round Hole Wiring Duct

Wiring Duct !PANDUCT Flexible Wiring Duct !PANDUCT Low Smoke Slotted Wall Wiring Duct !Wiring Duct Accessories and Installation Tools

!ULTIMATE ID System !Work Area !Zone Cabling !Patch Panels, Copper Patch

Cords & Punchdowns !Fiber Connectors, Enclosures & Patch Cords

32