The Capacity of the Evacuation Compressor is 1200 kg/hr. Considering entire quantity the evacuation is required to be done up to 2 kg/cm 2g. Time required for the mass to be evacuated = (Mso / Capacity) * 60
= (111.08 / 1200) * 60 = 5.554 mins. Evacuation compressor is designed to evacuate the system up to 2.0 kg/cm 2g. Hence the residual propane needs to be flared in case of maintenance of compressor. OWNER PMC LSTK CONTRACTOR
In case of worst condition of evacuation at 16 kg/cm 2 A and temperature 341.3 K, Total mass to be evacuated = (Msd / Vad) * Vso
= (45.67 / 1.5) * 9.60 = 292.288 kg Time required for the mass to be evacuated = (292.288 / 1200) * 60 = 14.6144 mins.
CONCLUSION To evacuate the propane gas, M/s. SAVAIR / IHI has selected a 2 cylinder double-acting ESH-series machine for the application (8 & 6.5 X 11 ESH-2 NL-2) having capacity of 1200 kg/hr at suction pressure 1.97 kg/cm2g and suction temperature of 46oC. Hence, the machine is sized adequately and can evacuate the Main Compressor under any settle-out condition within 3 / 15 minutes which is the defining criteria for sizing.
ENCLOSURE 1. Settle Out Pressure Calculation (Doc. No. 6972-010-50-02-CAL-0008 Rev. B) : Code RFR
OWNER
PMC
LSTK CONTRACTOR