You are on page 1of 4

Technical Data sheet: A. S. No.

1 2 3 Make Model Quantity STC 4 5 6 7 8 9 10 11 12 13 14 Nominal Maximum Power-Pmax (Watt) Optimum Operating Voltage-Vmp (Volts) Optimum Operating Current-Imp (Amps) Open circuit voltage-Voc (Volts) Short circuit current-Isc (Amps) Module Efficiency Operating Temperature Maximum System Voltage Maximum Series Fuse rating Application Classification Power Tolerance NOCT 15 16 17 18 19 Nominal Maximum Power-Pmax (Watt) Optimum Operating Voltage-Vmp (Volts) Optimum Operating Current-Imp (Amps) Open circuit voltage-Voc (Volts) Short circuit current-Isc (Amps) Mechanical Data 20 21 22 23 24 25 26 27 28 Cell Type Cell Arrangement Dimension Weight Front Cover Frame Material J-Box Cable Connectors Temperature Characteristics Solar PV Module Description Specification

29 30 31 32 B. Sl. No. 1 2 3 4 5

Temperature Coefficient Pmax ( % / C) Temperature Coefficient Voc ( % / C) Temperature Coefficient Isc ( % / C) Normal Operating Cell Temperature Solar Inverter Description Make Model Quantity Inverter Type Nominal Rating DC Input Specification

6 7 8 9 10 11 12 13 14 15 16

Maximum DC Power Maximum DC Voltage MPP Voltage Range at 230V AC DC Nominal Voltage Minimum DC Voltage at 230V AC Start Voltage Maximum input Current Number of MPP Trackers Maximum number of parallel strings Voltage ripple of input Voltage Internal consumption during Operation AC Output

17 18 19 20 21 22 23 24 25 26

AC nominal power at 230V AC, 50Hz Maximum AC apparent Power Nominal AC Current Maximum output Current Maximum Fuse Protection Harmonic Distortion of output current Nominal AC Voltage AC Voltage range AC Grid Frequency Operating Range of Grid Frequency

27 28 29 30 31

Power Factor at Nominal AC Power Overvoltage category Test Voltage at 50Hz Surge Testing Voltage Surge Testing Voltage with Serial Interface

32 33

Internal consumption in night mode Maximum Efficiency Mechanical data

34 35

Dimension Weight Climatic Condition

36 37 38

Operating Temperature range Humidity Range Maximum Operating altitude Features

39

Topology General Data

40 41 42 43

Protection rating Protection Class Noise Emission Cooling Concept Protective Equipment

44 45 46 47 48 49 50 51 52 53

DC-side disconnection device Ground Fault Monitoring/Grid Monitoring DC reverse polarity protection AC Short circuit current capability Galvanic Isolation DC overvoltage protection Pole confusion protection AC short circuit protection All-pole AC disconnection unit Communication Interface

C. Sl. No. 1 2 3 4

Monitoring System Description Make Model Quantity Type Communication Specification

5 6 7 8

Inverter communication PC Communication Maximum Communication range Maximum number devices communicated

9 10 11 12 13 14 15 16 17 18 19 20

Voltage Supply Quantity and Type of Battery Ambient Temperature Degree of Protection Mounting Location Mounting Type Status Display Software Software Language Operation Plant Data monitored Accessories

You might also like