M21 Transmitter

Single Channel Universal Gas Monitoring


The Millennium II (M21) single channel universal transmitters have been engineered from the ground-up to include the innovative features that managers and operators in the field demand, while providing rock solid day-to-day operation, even in the most extreme conditions. The Millennium II redefines what you expect from a fixed gas detection solution.
SMART Sensor Technology Compatible with All Sensor Types (Infrared, Catalytic Bead, Electrochemical, and NE-MOS) -55C to +85C Temperature Range Lowest Power Consumption Available Full Diagnostics with Event and Data Logging

SMART Gas Detector Series

Wide Voltage Range Allows For Greater Stability and System Compatibility Intuitive Menu System Provide Operators with a Non-intrusive Set-up and Calibration Interface Field Selectable Gas Curves and Ranges Long Range (+2000ft.) Sensor Separation

SMART Sensor Technology


The transmitter can be fitted with a wide range of toxic and/ or combustible gas sensors. SMART (Self Monitoring Analysis and Reporting Technology) sensors are pre-calibrated and easily connected to the transmitter which recognizes a newly fitted sensor, automatically uploading its specific configuration profile.

Superior OLED Display


The only full graphic OLED display available, easy to read in all ambient lighting conditions and operates down to -55C!

Analog, Relay, Modbus RS485 RTU & HART


Multiple communication protocols are available combined with Relays to allow the M21 Transmitter to work seamlessly with your system.

Digital Communications
Sensor and transmitter continuously communicate digitally, giving you the confidence of stable, accurate protection with fast response times even over long separation distances.

Field-proven Sensor Innovations


All of our sensors are engineered to be fast and reliable with field-proven performance in the harshest industrial conditions possible. These include Nano-Enhanced Metal Oxide Semiconductor (NE-MOS) toxic gas sensors that do not fall asleep and a full range of fast response Electrochemical toxic gas sensors. For combustible gas detection, poisonresistant Catalytic Bead technology with SensorGuard, which greatly prolongs sensor life and Infrared sensor technology utilizing a dual beam design with no mirrors that can become contaminated (fogged up) or misaligned.

Global Certifications
The Millennium II is approved to international hazardous area safety standards for operation and performance.

Easy To Use Menus


English, French, Portuguese or Spanish display languages included. The full text menu makes installation, operation and calibration simple. No manual necessary!
PMS - Uncoated

PMS - Coated

CMYK

Millennium II Gas Detection Transmitter


FGD_PDS_M21_Gas_Detection_Transmitter

Product Data Sheet


April 2013

M21 Transmitter
Specifications
Electrical Power Consumption Voltage Range EMC Compliance Display Environmental Temperature Relative Humidity Enclosure Metallurgy Conduit Opening Outputs Aluminum or 316 SS 3/4 NPT (3X) Standard: Analog 4-20mA Optional: Four 5 Amp Form C Relays, RS 485 Modbus RTU, and HART Certifications North American Class I, Division 1, Groups BCD; Class I, Zone 1, Group IIB+H2 Type 4X, IP67 FM 6310/6320, ANSI/ISA 12.13.01/92.0.01/92.03.01, CSA-C22.2 No152 ATEX 0575 II 2 G Exd IIB+H2 T5 IP67 IEC61779-1 & IEC61779-4 IECEx (pending) INMETRO Ex d IIB+H2 T5 Gb IP67 GOST-R SIL2 Rated* Sensors Warranty Mounting Weight Combustible Gases: SC3 Series Infrared and Catalytic Bead Toxic Gases: ST3 Series Electrochemical and NE-MOS 3 years Surface Mount / Pipe Mount / Duct Mount Aluminum: 2.4 kg (5.3 lbs), Stainless Steel (316SS): 2.6 kg (5.5 lbs) -55C to +85C (-67F to +185F) Certified Operating Range 0-99% RH non condensing 2.4W @ 24 or 12 Vdc (average - varies by sensor types/quantities) 10.5 32.0 Vdc (HART: 18 32 Vdc) EN 50270:2006 per EMC directive 2004/108/EC Organic LED (OLED), Power/Status LEDs

SMART Gas Detector Series


ORDERING INFORMATION
M21-A* M21-AR* M21-AD* M21-ARS* M21-AH M21-AHR Single Channel - Analog Single Channel - Analog & Relay Single Channel - Analog & Modbus Single Channel - Analog & Solid State Relays Single Channel - Analog & HART Single Channel - Analog & HART & Relay

M21-ARD* Single Channel - Analog & Relay & Modbus

Enclosures Available: Aluminum (-A) Stainless Steel (-S)

Ordering Matrix Example:


M21-AD-S (Transmitter - Output - Enclosure Material)

SPECIAL FEATURES
Current loop text jacks for each channel on faceplate Non-intrusive one man calibration (magnetic switch) Field selectable toxic gas ranges Redundant menu access via push buttons Sensor Enable / Disable option from menu (Cl1, Div2) Alarm relays configurable/assignable to any channel Displayed Event Logging (980 events) Easily retrieve last calibration data from sensor Four languages - English, French, Spanish, Portuguese

ACCESSORIES
Calibration Cup Mounting Bracket c/w Hardware Sun Shade/Deluge Protection Duct Mount and Hardware Kit Dust/Sand filter

A A

B B

C C

D D

E E

Aluminum Housings 142 5.4 5.4 137 137 E 246 6.06.0 152 152 Aluminum Housings 9.79.7 246 A 6.36.3160 B 160 5.65.6 C 142 D Stainless Steel Housings 150 5.1 130 117 8.9 226 226 6.06.0 152 152 Aluminum Housings 6.3 160 5.6 142 5.1 5.4 137130 9.7 246 6.0 8.9 152 Stainless Steel Housings 5.95.9 150 4.64.6 117
Stainless Steel Housings 5.9 F 150 5.1 F F 130 4.6

Aluminum Housings Aluminum Housings Aluminum Housings 5.7 Stainless Steel Housings Stainless Steel Housings Stainless Steel Housings 5.8
PMS - Uncoated

145 2.62.6 66 66 2.92.9 74 74 4.14.1 103 103 5.75.7 145 145 2.6 66 2.9 74 4.1 103 147 2.6 66 100 5.85.8 147 2.92.9 147 2.6 66 2.6 2.9 74 663.9 10074 74 3.93.9 100

117 G G H

8.9 I

226

H H

6.0

152

PMS - Coated

CMYK

Millennium II Gas Detection Transmitter


FGD_PDS_Gas_Detection_Transmitter

Product Data Sheet


April 2013

Millennium II Series
SEPARATION BOXES
JB-MPD-S JB-MPD-A

Separation Boxes & Accessories


Digital Output - Stainless Steel Digital Output - Aluminum

SMART Gas Detector Series

Class 1, Division 1, Groups BCD - Class 1, Zone 1 -- Enclosure rated NEMA 4X, IP67 (See man-0081 for full specifications)

ACCESSORIES
UDM-001 UDM-002 UDM-003 UDM-EX1 UDM-EX2 Universal duct mount assembly with 1M inlet sampling pipe - Stainless Steel Universal duct mount assembly with 1.5M inlet sampling pipe - Stainless Steel Universal duct mount assembly - Stainless Steel 1M extension - for use with UDM-001 & UDM-002 - Stainless Steel 1.5M extension - for use with UDM-001 & UDM-002 - Stainless Steel Calibration Cup/Rain Shield/Splash Guard/Dust Filter with DF-1 Dust / Sand protective clip (includes DF-1 disposable filter) IP 66/67 Filter for SX3 Series sensors, enhanced sensor protection from contamination by dirt and moisture 1 Pipe Mounting kit c/w stainless steel mounting bracket and hardware 2 Pipe Mounting kit c/w stainless steel mounting bracket and hardware 3 Pipe Mounting kit c/w stainless steel mounting bracket and hardware HART Communicator port, mounts directly to JB-MPH-A/S or Millennium II transmitter Separation box - Aluminum - used to remote mount HART port (HPT-001) Separation box - Stainless steel - used to remote mount HART port (HPT-001) 1 Pipe Mounted Sun shade kit/rain guard - Stainless steel - Includes UN-MK-31 Mounting kit 2 Pipe Mounted Sun shade kit/rain guard - Stainless steel - includes UN-MK-32 Mounting kit 3 Pipe Mounted Sun shade kit/rain guard - Stainless steel - Includes UN-MK-33 Mounting kit


CCS-1 DSC-1 IPF-001


UN-MK-31 UN-MK-32 UN-MK-33 HPT-001 JB-MPH-A JB-MPH-S


SSK-51 SSK-52 SSK-53

PMS - Uncoated

PMS - Coated

CMYK

Millennium II Gas Detection Transmitter


FGD_PDS_M21_Gas_Detection_Transmitter

Product Data Sheet


April 2013

HEADQUARTERS: FLAME AND GAS DETECTION Emerson Process Management Net Safety Monitoring Inc. 2721 Hopewell Place NE Calgary, Alberta, Canada T1Y 7J7 T +1 (403) 219 0688 T 1 866 FIREGAS F +1 (403) 219 0694 www.net-safety.com

2013 Emerson Process Management. All rights reserved. Emerson Process Management, Rosemount Analytical, and Net Safety Monitoring are marks of Emerson Process Management group of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.

Please refer to manuals for complete specifications.

PMS - Uncoated

PMS - Coated

CMYK

You might also like