Technical Information Sheet KP10-HB

MULTISTAGE PROTECTION for HIGH DENSITY MDF MODULES

Eart hing The protectors are referenced to earth via the frame of the KRONE disconnect block. It is essential that the connection between the frame and ground is of high integtrity. Specifications
Description: Protection modes: Single pair KRONE * HIGHBAND module protector Transverse & common modes Series. Plugs directly into * KRONE HIGHBAND disconnect blocks 200V -40 85C 0 90% 350mA To 20MHz 10kA per mode (8/20us) 75V ITU (CCITT) IX K17 AS1768-1991 cat. A, B AS4117-1999 Class 3 BS6651 cat C CP33-1996 cat. A, B IEC61643-21 UL497B N2530 In-line resistance: 8.2 ohms

Introduction
Modern digital switching systems are highly susceptible to transient voltage disturbances. The traditional protection offered by shunt-connected gas-filled arresters is no longer a suitable form of protection for these switches. Novaris MDF module protectors feature dual stage protection providing lower let through voltages that provide a safe working environment for sensitive digital equipment.

Connection type:

Voltage standoff: Working temperature: Working humidity: Current rating: Bandwidth: Surge handling: Let-through voltage: 5kV 10/700us pulse: Standards compliance:

O p erat io n Novaris single pair protectors are dual stage overvoltage protection modules designed for the protection of PSTN equipment and low voltage control circuits, against transient overvoltages caused by lightning, induced impulses and other voltage surges.
Each protection module contains a circuit that has primary protection provided by a gas-filled arrester and secondary protection provided by clamping diodes. The two stages are balanced by series impedance that has been designed to minimise the let-through voltage and maximise the life of the protector. KP10 protection modules are virtually maintenance free as they are designed to fail-safe. The PCB tracks between the line side terminals and gas arrester primary protection act as fuses, causing the line to open circuit in the event of a surge exceeding the capacity of the primary arrester. This failure mode is preferred to an open-circuit arrester that gives no indication of failure. If such a failure occurs, service is interrupted giving a positive indication of a fault condition.

Options
Cat No. KP8-HB/PSTN KP10-HB/PSTN KP8-HB/ISDN KP10-HB/ISDN KP8-HB/DSL KP10-HB/DSL Number of Pairs 8 10 8 10 8 10

* KRONE HIGHBAND is a trademark of Krone GmbH,


Germany

Novaris Pty Ltd


72 Browns Road, Kingston, TAS. 7050 AUSTRALIA Copyright 2004 Novaris Technologies E-mail: sales@novaris.com.au ABN: 33 065 427 232 TEL: +61 3 6229 7233 FAX: +61 3 6229 9245