You are on page 1of 8

Duct air-handling units

en_vt_v1_01.indd 1 5.5.2009 9:53:09


Duct air-handling units
Why Vento?
Duct units Vento are constructed to help to implement comprehensive but simple air handling devices at
the same tme. Only Vento ofers You 10 advantages:
O
Variability and compactness of products
possibility to create even complex devices
Air inlet and exhaust
Heatng and cooling
Heat recovery and mixing
Control
O
Placing optons saves space and costs
Can be installed in any positon
Separate components can be installed to the duct
Installaton by suspending under the ceiling in service
rooms of buildings eliminates need of machine room
Using existng supplies distributon lowers installaton
costs
O
Optonal material types
satsfy every requirement
All products can be made of stainless metal-sheets
Atested fan for environment with explosion risk
Coloured fnish at request
O
Convenient for use in demanding operatons
Regarding operaton, maintenance and control the devices
are comparable with air-handling units
Proper installaton satsfes even demanding requirements
for comfort (for example. noise)
Ideal for reconstructons and spatally complicated
buildings
Noise insulated fans
O
Excellent price cheapest air handling and
air conditoning system
Low price of separate components
Standard design of roof fans made of aluminium
Complex delivery from one supplier lowers purchase costs
O
Exceptonal speed and quality of deliveries
in tme and with guarantee
Fast complex deliveries from stockhouse
O
Very easy installaton
fast and cheap installaton
Low weight of device
Simple connecton of components
Easy handling without handling devices
Possibility of additonal PE insulaton
O
High quality
operaton without any problems
Used only proofed materials and componens
Long service life (fans: 40 000 hours of operaton)
Easy change of flters
Low operaton costs (output power control, low input
power)
Up to 5 years of guarantee
O
Excellent adjustablility optmizes coziness
of air-conditoned rooms
5 stage fan speed control voltage controller, frequency
inverter (WebClima or VCB control unit)
Perfectly controlable heatng and cooling
Complex control and regulaton systems
Simple implementaton of the equipment with automatc
control
G
Selecton of parts and project processing
sofware AeroCAD with elements of virtual
reality
Optmal placing of device to the room of installaton
Calculaton of all output parameters power outputs,
pressures, temperatures, noises, pressure losses
and gains of separate components, relatve and
specifc humidity, density, enthalpy, real and mass air
fow rate etc.
Professional 2D, 3D pictures for import to CAD
systems
Individual processing of quotatons
Comprehensive graphically processed calculatons
Automatc projecton of control saves costs on project
of measuring and control
en_vt_v1_01.indd 2 5.5.2009 9:53:09
Perfect and comprehensive project
Calculaton of fan parameters
example of arrangement
with fan, elastc connectons, water
heatng, insert flter and control damper
with actuator
example of arrangement
with fan, elastc connectons, direct
evaporator, electric heatng, bag flter
and control damper with actuator
example of arrangement
with 2 fans, elastc connectons, water
cooler, water heater, bag and insert
flter and mixing secton
example of arrangement
with 2 fans, elastc connectons, plate
heat exchanger, water heatng, cooling
and control dampers
Unique comprehensive graphical projectng and
calculaton program AeroCAD is at your disposal
when projectng Vento units.
Projected device
en_vt_v1_01.indd 3 5.5.2009 9:53:12
Duct air-handling units
Water heater
VO
Shut ng damper
LKS
Radial fan
RP
Plate heat exchanger
HRV
Bag lter
KFD
Noise atenuator
TKU
Elbows
OBL
en_vt_v1_01.indd 4 5.5.2009 9:53:15
Duct air-handling units
Water heater
VO
Plate heat exchanger
HRV
Cooler direct evaporator
CHF
Insert lter
VFK
Radial fan
RO
Elastc connecton
DV
Noise atenuator
TKU
en_vt_v1_01.indd 5 5.5.2009 9:53:19
Duct air-handling units
mixing sectons with
contnuous mixing control
motors can be easily cleaned explosion proof fan types
easily changeable lters
radial spiral fans
el. heaters with built-in switching
elements(SSR)
en_vt_v1_01.indd 6 5.5.2009 9:53:22
Duct air-handling units
high-performance
drop eliminators
water heaters with
automatc deaeraton
roof fans for air outlet
coolers with built-in ant-freeze
protecton and condensate
drain kit
el. heaters with built-in switching
elements(SSR)
motors are wired to
terminals which makes
wiring easy
control and regulaton are
provided by linked systems
with comprehensive
protecton elements
en_vt_v1_01.indd 7 5.5.2009 9:53:25
THE EUROPEAN REGIONAL DEVELOPMENT FUND AND THE MINISTRY
OF INDUSTRY AND TRADE OF THE CZECH REPUBLIC SUPPORT
INVESTMENT IN YOUR FUTURE.
REMAK a.s.
Zubersk 2601, 756 61 Ronov pod Radhotm
tel.: +420 571 877 778, fax: +420 571 877 777
www.remak.eu
R
0
8
0
6
0
4
0
7
Duct air-handling units
TKU 60-30
30-20
40-20
50-25
50-30
60-30
60-35
70-40
80-50
90-50
100-50
300-200
400-200
500-250
500-300
600-300
600-350
700-400
800-500
900-500
1000-500
30-15
1
0
0
-
5
0
9
0
-
5
0
8
0
-
5
0
7
0
-
4
0
5
0
-
2
5
60-35
4
0
-
2
0
50-30
6
0
-
3
0
9001
ISO
RF
RP
Heat recovery Noise atenuaton
Cooling Mixing
Heatng Filtraton
T
h
e

p
r
o
d
u
c
e
r

r
e
s
e
r
v
e
s

r
i
g
h
t

f
o
r

c
h
a
n
g
e
s

w
i
t
h
o
u
t

p
r
e
v
i
o
u
s

n
o
t

c
e
.
Air ow rate and pressure loss Sizes and dimensions
middle frequency of octave range
Air fow rate [m
3
/h]
S
t
a
t

c

p
r
e
s
s
u
r
e

[
P
a
]
High-performance heat exchanger
(energy saving in relaton to water heater output power)
s
i
z
e
c
o
n
n
e
c
t

n
g

d
i
m
e
n
s
i
o
n
s

(
m
m
)
Bag lter
Filtraton class EU3-EU7
Insert lter
Filtraton class EU3
Connectng
cross secton AxB (mm)
Nominal output powers of heaters
(temperature gradient of water 90/70C)
Nominal output powers of coolers
(temperature gradient of water 6/12C)
Illustraton of mixing functon
100%
of fresh air
50%
of fresh air
0%
of fresh air
Atenuaton of noise atenuators
Electric heater
Water heater (90/70C)
Direct evaporator
(Coolant R407c)
Water cooler (6/12C)
en_vt_v1_01.indd 8 5.5.2009 9:53:36