You are on page 1of 4

Jignesh.

Parmar,
www.electricalnotes.wordpress.com
jiguparmar@yahoo.com

Minimum IR Value for Rotating Machine (AC or DC)


Machine Terminal to Terminal Voltage

0.44

KVA

IR (Min) for Machine

1.44

50
440
1.6

Hz
Volt
KVA

Minimum IR Value for Transformer


50 Hz
Frequency
Voltage Rating of winding under Test
Rated Capacity of Winding under Test
Select Type of Transformer
Tank Oil Filled T.C
Without Tank Oil filled T.C
Dry or Compound Fill T.C
IR (Min) for Transformer

1
2
3

521.8

25 Hz
1.5
30
30

2
1
20
20

1.5

Minimum IR Value for Cable


Type of Cable
Type of Insulation Material

1
3

Outer Diameter of Conductor Insulation


Diameter of Conductor
0

1
2
3
4
5
6

Paper
Varnished
ThermoPlastic-Polyethylene
Composite-Polyethylene
Polyvinyle Chloride (60C)
Polyvinyle Chloride (75C)

IR (Min) for Cable

50000
Minimum IR Value for Domestic Wiring
Case-1
Case-2

No of Outlet (All Point,Plugs with Fitting(Lamp etc))


IR(min) value
Excellent
No of Outlet (All Point,Plugs without Fitting(Lamp etc))
IR(min) value
Excellent

2640 1 Core
2460 Multicore
50000
30000
500
2000

25
2.00
25
2.00

M
M

Jignesh.Parmar,
www.electricalnotes.wordpress.com,
jiguparmar@yahoo.com

Measured IR
Value (M)
3
2
4
5
5
2
2
5

2-Jan-10
1-Jan-10

2
2

Temperatur IR Value after


Temperature e
Temperature
(C)
Correction Adjucment
Factor
(M)
42
1.15
3.45
56
3.03
6.06
55
2.83
11.31
30
0.50
2.50
32
0.57
2.87
34
0.66
1.32
34
0.66
1.32
10
0.13
0.63
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
24
0.33
0.66
30
0.50
1.00

Volt

IR Value (M)

100 100V DC or 250V DC


200 100V DC or 250V DC
300 100V DC or 250V DC

12.00
10.00
8.00
6.00
3.45
4.00
6.06

1-Jan-10
1-Feb-10
1-Mar-10
1-Apr-10
1-May-10
1.32
2-May-10
1.32
3-May-10
0.63
5-May-10
6-May-10
7-May-10
8-May-10
9-May-10
10-May-10
11-May-10
12-May-10
13-May-10

11.31
2.00
2.50
0.00
2.87

0.66
1.00

2-Jan-10
1-Jan-10

2-Jan-10
1-Jan-10

Date
1-Jan-10
1-Feb-10
1-Mar-10
1-Apr-10
1-May-10
2-May-10
3-May-10
5-May-10
6-May-10
7-May-10
8-May-10
9-May-10
10-May-10
11-May-10
12-May-10
13-May-10

230
100V DC or 250V DC
40

1-Jan-10
1-Feb-10
1-Mar-10
1-Apr-10
1-May-10
2-May-10
3-May-10
5-May-10
6-May-10
7-May-10
8-May-10
9-May-10
10-May-10
11-May-10
12-May-10
13-May-10

Name of Equipment
Rated Voltage of Equipment
Recommended Megger Size
Reference Temperature (C)

400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
6000
7000
8000
9000
10000
11000
12000
13000

500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
50000V DC or 10000V DC

Jignesh.Parmar,
www.electricalnotes.wordpress.com
jiguparmar@yahoo.com

Name of Equipment
Rated Voltage of Equipment
Recommended Megger
Insulation Class
Reference Temperature (C)

Date

Measured IR
Value (M)
(for 10
Minitue)

adwa
440
500V DC or 1000V DC

Volt

40

Measured IR
Temperatur
Value (M) Temperature e
(for 1
(C)
Correction
Minitue)
Factor

1-Jan-10
1-Feb-10
1-Mar-10
1-Apr-10
1-May-10
2-May-10
3-May-10
5-Jun-11

2
4
5
3
2
4
2
3

1
2
1
1
1
1
2
4

42
56
55
30
32
34
34
42

1-Jan-10

23

1.15
3.03
2.83
0.50
0.57
0.66
0.66
1.15
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.31

Polarization Index
Number after
Insulation
Temperature
Condition
Adjucment
2.00
2.00
5.00
3.00
2.00
4.00
1.00
0.75
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.67

Questionable
Questionable
Excellent
OK
Questionable
OK
Poor
Poor

Poor

PI Value
6.00

5.00
4.00
3.00
2.00

1.00
0.00

2.00 1-Jan-10
2.00 1-Feb-10
5.00 1-Mar-10
3.00 1-Apr-10
2.00 1-May-10
4.00 2-May-10
1.00 3-May-10
0.75 5-Jun-11

0.67

1-Jan-10

100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
6000
7000
8000
9000
10000
11000
12000
13000

100V DC or 250V DC
100V DC or 250V DC
100V DC or 250V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
500V DC or 1000V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
1000V DC or 2500V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
2500V DC or 5000V DC
50000V DC or 10000V DC

The Earth Resistance Value

Jignesh.Parmar,
www.electricalnotes.wordpress.com,
jiguparmar@yahoo.com

Earth Tester/Megger (4 Terminals)

DirectionI
1
2
3
4
5
6
7

DirectionII

Date
1-Jan-10

Date

1
2
3
4
5
6
7

Electrode
Spacing
(S) (Meter)
1
2
5
10
15
25
50
Electrode
Spacing
(S) (Meter)
1
2
5
10
15
25
50

Megger Rading
in Ohms

P2

C1

C2

Earth Resistivity
Remarks
Ohm-Meter
0
0
0
0
0
0
0

Megger Rading
in Ohms

P1

Power Station
EHT SubStation
66KV SuStation
D.P Structure
Tower Foot Resistance

30 to 50 Cm

Earth Resistivity
Remarks
Ohm/Meter
0
0
0
0
0
0
0

Location of Earth Resistivity Measurement


1

DirectionIII

Date

1
2
3
4
5
6
7

DirectionIV

Date

1
2
3
4
5
6
7

DirectionV

Date

1
2
3
4
5
6
7

DirectionVI
1
2
3
4
5
6
7

Date

Electrode
Spacing
(S) (Meter)
1
2
5
10
15
25
50
Electrode
Spacing
(S) (Meter)
1
2
5
10
15
25
50
Electrode
Spacing
(S) (Meter)
1
2
5
10
15
25
50
Electrode
Spacing
(S) (Meter)
1
2
5
10
15
25
50

Megger Rading
in Ohms

Earth Resistivity
Remarks
Ohm/Meter
0
0
0
0
0
0
0

Megger Rading
in Ohms

Earth Tester/Megger (3 Terminals)


P
E

Earth Resistivity
Remarks
Ohm/Meter
0
0
0
0
0
0
0

Megger Rading
in Ohms

Earth Resistivity
Remarks
Ohm/Meter
0
0
0
0
0
0
0

Megger Rading
in Ohms

Earth Resistivity
Remarks
Ohm/Meter
0
0
0
0
0
0
0

75 Feet

75 Feet

< 0.5
< 1.0
< 2.0
<5.0
<10.0

You might also like