Preface
The Infinity CMX Installation Guide presents instructions for installing the various CMX controllers on an EnergyNet network. It first presents site preparation information and then step-by-step installation instructions. We recommend you read EnergyNet and Infinet Configuration Guide to plan your entire network before installing a single controller.
iii
www.PDF-Zoo.com
iv
www.PDF-Zoo.com
Contents
www.PDF-Zoo.com
Wiring Infinet to CMX ................................................................16 Connecting the Audio Speaker ....................................................17 Powering Up the CMX ..........................................................................18 Connecting the Battery ................................................................19 Interpreting Status Lights Inside Cabinet ...............................................20 Using the CLEAR MEMORY Button .........................................21 Connecting the Andover Controls Service Tool ..........................21
vi
www.PDF-Zoo.com
Figures
Figure 1. Dimensions and Eyelets for Mounting CMX Controller .....11 Figure 2. Metal Plate and Screw for Power Supply Wire ....................12 Figure 3. Cable Ports and Connectors on the CMX 220 Controller ....15 Figure 4. Infinet Cable Wiring ............................................................16 Figure 5. Audio Speaker Wiring ..........................................................17 Figure 6. System Activity Status Lights ..............................................20 Figure A-1. Pinouts for Cables Connecting to RS-232 Ports on CMX Controller .................................................................. A-3
vii
www.PDF-Zoo.com
Tables
Table 1.
viii
www.PDF-Zoo.com
The appendix gives the pinouts for the RS-232 port cables.
Warranty Registration
Your warranty is effective for 18 months starting on the date the system is shipped.
www.PDF-Zoo.com
Warning
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Avis
Le prsent appareil numrique nmet pas de bruits radiolectriques dpassant les limites applicables aux appareils numriques de la class A prescrites dans le Rglement sur le brouillage radiolectrique dict par le ministre des Communications du Canada.
www.PDF-Zoo.com
Warning
All wiring and installations must comply with local, state, and national electrical codes.
www.PDF-Zoo.com
Cabinet Dimensions
Each Infinity CMX cabinet is approximately 11.5 10.6 2.45 in.
Power Requirements
Warning
Be sure your installation complies with local, state, and national electrical codes.
Caution
The CMX should receive power from its own independent, unswitched circuit. The CMX requires 24 VAC +/-20%, 50/60 Hz rated at 20 VA.
www.PDF-Zoo.com
Built-in Modem
The built-in modem, an optional feature of the CMX, has a 2400 baud rate.
Infinet Cables
The maximum cable length for Infinet is 4,000 ft at 19,200 baud (up to 32 Infinet controllers). You can extend Infinet beyond 4,000 ft or put more than 32 Infinet controllers on less than 4,000 ft by using the InfiLink 200 amplification module. Cables that form Infinet are 24-gauge, single-twisted-pair, tinned, shielded copper wire. Use the following cables1 or their equivalents:
Note
You must use shielded cables for Infinet to ensure compliance with the Class A FCC limits and to communicate reliably. Brand Rex # H 9002 (single-pair) Anixter # 9J2401021 (single-pair plenum cable) The cable should have a nominal impedance of 100 and a nominal velocity of propagation of 78%. Capacitance of Infinet cable should be nominal, below 12.5 pF/ft between conductors and below 22 pF/ft between the conductor connected to ground and the next conductor.
1. You can also use any cables you may already have in place for ACNET or LBUS.
www.PDF-Zoo.com
CMX 230 are differences in what you can program them to do. For details, see the Andover Controls Infinity CX Programmers Guide.
Lightning Protection
Warning
When running cables (Infinet or input/output wire) between buildings you must install lightning arresters for Infinet to prevent electromagnetic disturbances. Use lightning arresters at each point where Infinet cable enters or exits a building. Use the following arrester: Two pair gas tube arrester, Andover Controls # 01-2100-299.
www.PDF-Zoo.com
Warning
Be sure to have your grounds inspected before you begin the installation process to be sure your municipality follows the National Electrical Code. Many municipalities do not and often have substandard electrical grounds. An example of a substandard ground is a galvanized steel cold water pipe. As the pipe corrodes, it does not act as a true ground. The corrosion acts as an insulator, raising the potential of the pipe with respect to the ground. When lightning strikes in the area of the installation, it drastically changes the potential of the earth. Since properly grounded Andover Controls units respond to changes in potential more rapidly than poorly grounded electrical systems, a poorly grounded building tries to reach ground through the Andover Controls system. The surge of current can destroy electronic components on the controller board. Surges of much lower potential than lightning also impact the reliability of Andover Controls equipment.
www.PDF-Zoo.com
Environmental Requirements
The CMX controllers operate in rooms with temperatures ranging from 40 to 120F and with humidity between 10 and 95%, noncondensing. The controller must be in an Underwriter Laboratories approved enclosure.
www.PDF-Zoo.com
at any given time. The distant terminal automatically logs out the nearby terminal; so when planning your site, remember you can use only one terminal or the other at a given time and schedule time accordingly. You cannot connect an LBUS to a CMX controller. You cannot have an Infinity CX controller on the same Infinet with a CMX controller. Find the tag attached to each controller that gives the number of the controller. Before you remove any tags, be sure the tag has all of the following information on it: Location of the controller. Serial number. Model name and number. Then collect the tags. Youll need to know where your controllers are located when you later assign a name to each controller and each input and output.
www.PDF-Zoo.com
Parts Required
To install a single controller you start with the following parts: CMX Controller AC Power Cable Infinet Cable Telephone Cable (for connecting to optional built-in modem) Your Own Optional Speaker and Speaker Cable (not provided) RS-232 Cables for Terminal (see the appendix for specifications)
Warning
Never drill holes in the CMX cabinet or boards. A metal shaving could easily short circuit the electronics. 1. Pull the cable for a terminal through the middle opening on the left side of the cabinet. 2. Pull cables for Infinet through the lower left side opening. 3. Pull the AC cable through the opening on the top left side of the cabinet.
10 Infinity CMX Installation Guide
www.PDF-Zoo.com
10.400 8.75
MATERIAL GRAIN
5.200
.23
REF
11
www.PDF-Zoo.com
Caution
Be sure to connect all three wires, GND, RET, and 24V. Otherwise, the controller could malfunction. 2. Notice that the three wires at the end of your AC cable are black, white, and green. 3. Place the green wire under the metal plate behind the top screw, labeled GND. 4. Tighten the screw with a flathead screw driver. Figure 2 shows the position of the plate, where to place the wire, and how the screw fits on the plate. You can see how the screw holds the plate in place once you tighten it.
12
www.PDF-Zoo.com
5. Place the white wire under the metal plate behind the middle screw, labeled RET. 6. Tighten the screw with a flathead screw driver. 7. Place the black wire under the metal plate behind the bottom screw, labeled 24V. 8. Tighten the screw with a flathead screw driver.
UserPort
Notice that the CMX has one RS-232 communication port, labeled USERPORT. You can attach a terminal (directly or via a modem) to this port. USERPORT cannot connect to an LBUS or Infinet cable and cannot connect to a modem. You may connect a printer to it, but since it is the only port and a terminal is required, in most situations a terminal belongs there.
Infinet Connector
The Infinet connector is just to the left and below from the RS-232 port on the left side of the board.
13
www.PDF-Zoo.com
Service Port
The port labeled SERVICE PORT connects the Andover Controls Service Tool to the CMX controller. You can carry around the tool and plug it in as required to see how the controller system is functioning. See your Andover Controls representative about availability of the tool.
14
www.PDF-Zoo.com
www.PDF-Zoo.com
2. Run telephone cable from the wall jack through the opening on the left side of the controller to the telephone jack (RJ 11 connector).
Note
You must use shielded cables for Infinet to ensure compliance with the Class A FCC limits and to ensure reliable communications. You wire the Infinet to the CMX using the following procedure: 1. Open the front of the controller cabinet. Notice that to the lower left is a port labeled Infinet. Notice that the end of the Infinet cable has two wires and a shield. You wire them to the block terminal connector on the Infinet port. 2. String the cable through the cable hole on the lower left side of the controller. Figure 4 illustrates how to wire the Infinet cable to the removable block terminal connector in the lower left corner of the CMX.
16
www.PDF-Zoo.com
2. Take the first wire for the incoming Infinet and the first wire for the outgoing Infinet and slip both in the hole beneath the screw labeled with a plus sign (top). 3. Tighten the screw down on them until the screw holds the wires in place. 4. Slip the second (usually black) wire from each Infinet cable under the screw labeled with a minus sign (middle) and tighten the screw down on them. 5. Slip the shields from the incoming and outgoing Infinet cables under the screw labeled SHLD (bottom) and tighten the screw down on them.
17
www.PDF-Zoo.com
18
www.PDF-Zoo.com
6. If the CPU light flashes every 0.1 sec, it means the CPU has failed a RAM or ROM test. See the Andover Controls Infinet Controller Troubleshooting Guide.
19
www.PDF-Zoo.com
20
www.PDF-Zoo.com
INFINET RDFlashes every 0.5 sec when the Infinet is receiving data. SCANFlashes once for every scan of the controller. ERRORLights up if the controller fails the internal integrity check. INFINET TDFlashes every 0.5 sec when the Infinet is transmitting data.
21
www.PDF-Zoo.com
22
www.PDF-Zoo.com
Appendix
A-1
www.PDF-Zoo.com
Table A-1. Pinouts for RS-232 Comm Port1 with Male DB25 Connector to Terminal
Pin Number Purpose 1 2 3 4 5 7 9 10 Chassis TD RD RTS CTS GND +V V Direction --From To From To --From From Required NO YES YES YES YES YES NO NO
1. To and from are in relation to the Infinity CMX controller. A-2 Infinity CMX Installation Guide
www.PDF-Zoo.com
Figure A-1. Pinouts for Cables Connecting to RS-232 Ports on CMX Controller
Female End Connecting to VT 100 or IBM PS/2 (25-pin) 2 3 7 Female End Connecting to Infinity CMX 2 3 7
A-3
www.PDF-Zoo.com
A-4
www.PDF-Zoo.com
Index
A
AC power wiring 12 Andover Controls Service Tool using 21
G
ground correcting 8 inspecting 8 requirements 7
C
cabinet dimensions 4 cable for Infinet 5 for lightning protection 6 Infinet port 13 LBUS port 13 RS-232 pinouts A-1 circuit requirements for power 4 codes complying with 4 communication ports locations of 13 computer connecting 14 configuration planning 8 CPU light inside 20
I
Infinet connecting 16 lightning arrester for 6 Infinet cable connecting 16 Infinet cable numbers 5 INFINET RD light inside 21 INFINET TD light inside 21
L
lightning arrester for Infinet 6
M
modem baud rate of 5 mounting steps to 10
D
DCD light inside cabinet 20 dimensions cabinet 4
P
parts requirements 10 power requirements 4 circuit 4 power surges preventing 7 powerup executing 18 procedure to prepare for 18
E
enclosure Underwriter Laboratories requirements 8, 10 ERROR light inside 21
R F
features unique to CMX 1 RD light inside 20 repair packaging required to ship for 10
Index-1
www.PDF-Zoo.com
S
SCAN light inside 21 service port location of 14 purpose of 21 shields for Infinet cable connecting 17 speaker amplification 5
T
TD light inside 20 temperatures for operating 8 terminal connecting 14
U
Underwriter Laboratories enclosure requirements 8, 10
W
wiring connecting Infinet cable 16 correct wire gauge for ground 8
Index-2
www.PDF-Zoo.com
30-3001-203