Name [Block capitals]_STEVE HUGHES Signature SE Hughes__Pipe ident__E17_ Code/Specification used (YOUR CODE) Welding processMMA__Joint type Single V Welding position_____2G__Outside and thickness_219 x 7 mm Date__12 march 03 Weld face
Cap height 3max Cap width 12-15 Toe blend smooth Hi/lo 0.5mm
A
67
B Undercut
1mm sharp 15 5
Cap height 3mm Cap width 12-14 Toe blend sharp Hi/lo 0.5mm Undercut Undercut Intermittent intermittent 2mm sharp 1mm sharp 60 35 165 To
103
75
25 Arc strikes
100
Pores (x3) 0 15
Undercut intermittent <0.5mm smooth Undercut 1mm 1mm sharp sharp 0 16 65 5 4 Undercut C
D
Arc strike 4 Arc strike 154 5
D
100
20
10
30
3 Porosity
60
7 Underfill
70
5 Arc strike
75
90
Arc strike
Cap height 1-4 Cap width 12-15 Toe blend sharp Pipe Hi/loIdent__ 0.5mm E17___
Cap height 3 Cap width 12-15 Toe blend sharp Hi/lo 1mm
Penetration height 0.5 - 4 Penetration width Toe blend poor Hi/lo 1mm
A
Burnthrough (cont) 0 20
B
155
Concavity 0 5mm To C
2 Slag inclusion
70
10
90
Spatter
Concavity < 0 5mm Penetration height 0 -1 Penetration width Toe blend smooth Hi/lo 0.5mm
Pipe seam
25 Concavity (cont) < 0.5mm Concavity < 0.5mm 3 Incomplete penetration 112 1 160
Burnthrough To A
48
WELD INSPECTION REPORT/SENTENCE SHEET Penetration height 0 - 2 Penetration height 0 - 4 Penetration width Toe blend smooth Toe blend poor Hi/lo 0.5mm Hi/lo 1mm
Defect type Reinforcement (height) Reinforcement (appearance) Incomplete filling Inadequate weld width Slag Inclusions Undercut Surface porosity Cracks/crack-like defects Lack of fusion Arc strikes Mechanical damage Laps/laminations Misalignment Longitudinal seams Root defects Misalignment Excessive root penetration Lack of root penetration Lack of root fusion Root concavity Root undercut Cracks/crackl-ike defects Slag inclusions Porosity Laps/laminations
A-A D-B D-A A-A B-D B-C/D-A A-A A-B A-A A-A
1mm max 4mm max 1mm None 0.5 deep 0.5 deep None 2mm None None
3 7.2 Not referenced 25 9.3.1 ----------------------1.6 max 9.3.6 0.8 9.7.2 ----------------------13 9.3.8.2 ---------------------------------------------
ACCEPT ACCEPT *** ACCEPT ACCEPT ACCEPT **** ACCEPT ACCEPT ACCEPT ACCEPT ACCEPT
This *pipe/plate has been examined to the requirements of [code/specification]API 1104 (19th edition).... .and is accepted/rejected accordingly.
Signature.......SE Hughes.............................. Date...........12 March 2003..........................................
* Arc strikes not referenced grind off and MPI/crack detect at company discretion. ** Mechanical damage not referenced but is smooth and not excessively deep refer to company. *** Root penetration not referenced but appears excessive at burnthrough refer to company. ****Root concavity assessed on radiographic density therefore must not exceed cap height-refer to graphs.