You are on page 1of 7

Railway-EMC-Standards prEN 50121-X

EMC TEST NRW

Welcome at

www.emc-test.de

the independent service provider for EMC

EMC Solutions - the first choice


1
15.09.2006 Uwe Rrden Revision prEN 50121-X : 2006

Overview EMC standards


Current standard EN 50121-1 : 09.2000 EN 50121-2 : 09.2000
www.emc-test.de

EMC TEST NRW

Title
Railway application Electromagnetic compatibility; Part 1: Generell Railway application Electromagnetic compatibility; Part 2: Emission of the whole railway system to the outside world Railway application Electromagnetic compatibility; Part 3-1: Rolling stock Train and complete vehicle Railway application Electromagnetic compatibility; Part Teil 3-2: Rolling stock Apparatus Railway application Electromagnetic compatibility; Part 4: Emission and immunity of the singalling and telecommunications apparatus Railway application Electromagnetic compatibility; Part 5: Emission and immunity of fixed power supply installations and apparatus

EN 50121-3-1 : 09.2000 EN 50121-3-2 : 09.2000 EN 50121-4 : 09.2000 EN 50121-5 : 09.2000

2
15.09.2006 Uwe Rrden Revision prEN 50121-X : 2006

prEN 50121-x : 02.2006

EMC TEST NRW

Reasons for revision ...


adaptation to technical progress
www.emc-test.de
e.g. expansion of frequency range (WLAN, Bluetooth, ...)

unification of measurement procedures


e.g. reference to standards EN 61000-4-x

elimination of mistakes / better understanding

3
15.09.2006 Uwe Rrden Revision prEN 50121-X : 2006

Changes in prEN 50121-3-1


EN 50121-3-1 : 2000
Radiated emission with special measurement procedure in standstill and slow moving with PEAK-detector (MAXHold) / 1 antenna polarisation

EMC TEST NRW

prEN 50121-3-1 : 2006


Radiated emission with special measurement procedure in standstill with QP-detector / MAX-Hold) and slow moving with PEAK-detector / MAXHold / 2 antenna polarisations Conducted and radiated immunity not tested. EMC plan for vehicle must be set up and implemented.

Comment
Change of limit lines and measurement procedure in standstill operation ! 2 antenna polarisations ! Higher expenditure of time ! No change in requirements !

www.emc-test.de 4

Conducted and radiated immunity not tested. EMC plan for vehicle must be set up and implemented.

15.09.2006 Uwe Rrden

Revision prEN 50121-X : 2006

Changes in prEN 50121-3-2


EN 50121-3-2 : 2000
Radiated emission according to EN 55011 Conducted emission according to EN 55011 Radiated immunity according to EN 61000-4-3 80-1000 MHz with 10/20 V/m

EMC TEST NRW

prEN 50121-3-2 : 2006


Radiated emission according to EN 55011 Conducted emission according to EN 55011 Radiated immunity according to EN 61000-4-3 80-1000 MHz with 20/10 V/m 800-1000 MHz with 20 V/m 1400-2100 MHz with 10 V/m 2100-2500 MHz with 5 V/m Conducted immunity according to EN 61000-4-2/-4/-5/-6 EN 61000-4-6 now with 10V !

Comment
No change in requirements ! No change in requirements ! Change of test procedure for 900 MHz and expansion of frequency range up to 2,5 GHz ! Additional test with higher expenditure of time ! No test of voltage variations and dips ! Higher SURGE-test => damage of apparatus ?

www.emc-test.de 5

Conducted immunity according to EN 61000-4-2/4/-6 and EN 50155 (SURGE / voltage variations and dips)

15.09.2006 Uwe Rrden

Revision prEN 50121-X : 2006

Changes in prEN 50121-4


EN 50121-4 : 2000
Radiated emission according to EN 50081-2 Conducted emission according to EN 50081-2 and EN 61000-3-x Radiated immunity according to EN 61000-4-3 80-1000 MHz with 10V/m ; and ENV 50204 9005 MHz with 10 V/m

EMC TEST NRW

prEN 50121-4 : 2006


Radiated emission according to EN 61000-6-4 Conducted emission according to EN 61000-6-4 and EN 61000-3-x Radiated immunity according to EN 61000-4-3 80-1000 MHz with 10V/m 800-1000 MHz with 20 V/m 1400-2100 MHz with 10 V/m 2100-2500 MHz with 5 V/m Magnetic fields test according to EN 61000-4-8 with 0/16,7/50Hz, 100 A/m AC-system and 300 A/m DC-system EN 61000-4-9 with 300 A/m Conducted immunity according to EN 61000-4-2/-4/-5/-6/-12

Comment
No change in requirements ! No change in requirements ! Change of test procedure for 900 MHz and expansion of frequency range up to 2,5 GHz ! Additional test with higher expenditure of time !

www.emc-test.de

Magnetic fields test according to EN 61000-4-8 with 50Hz, 100 A/m EN 61000-4-9 with 300 A/m Conducted immunity according to EN 61000-4-2/-4/5/-6
15.09.2006 Uwe Rrden

No change in requirements !
Revision prEN 50121-X : 2006

Changes in prEN 50121-5


EN 50121-5 : 2000
Radiated emission according to EN 50081-2 Conducted emission according to EN 50081-2 and EN 61000-3-x Radiated immunity according to EN 61000-4-3 80-1000 MHz with 10V/m ; and ENV 50204 9005 MHz with 10 V/m

EMC TEST NRW

prEN 50121-5 : 2006


Radiated emission according to EN 61000-6-4 Conducted emission according to EN 61000-6-4 and EN 61000-3-x Radiated immunity according to EN 61000-4-3 80-1000 MHz with 10V/m 800-1000 MHz with 20 V/m 1400-2100 MHz with 10 V/m 2100-2500 MHz with 5 V/m Magnetic fields test according to EN 61000-4-8 with 0/16,7/50Hz, 100 A/m Conducted immunity according to EN 61000-4-2/-4/-5/-6/-12 + EN 61000-6-4 on earth connection

Comment
No change in requirements ! No change in requirements ! Change of test procedure for 900 MHz and expansion of frequency range up to 2,5 GHz ! Additional test with higher expenditure of time !

www.emc-test.de

Magnetic fields test according to EN 61000-4-8 with 50Hz, 100 A/m Conducted immunity according to EN 61000-4-2/-4/5/-6/-12

One additional test.

7
15.09.2006 Uwe Rrden Revision prEN 50121-X : 2006