You are on page 1of 3

Hilti, Inc.

5400 South 122nd East Avenue


Tulsa, OK 74146
(918) 252-6000

May 1, 2013
RE:

New Hilti HIT-HY 200 Safe Set Adhesive Anchoring System replaces
HIT-HY 150 MAX and HIT-HY 150 MAX-SD Adhesive Anchoring Systems

To Whom It May Concern:


The new Hilti HIT-HY 200 Adhesive Anchoring System is now available as a direct
replacement for both the HIT-HY 150 MAX and HIT-HY 150 MAX-SD Adhesive
Anchoring systems in concrete applications. The Hilti HIT-HY 150 MAX and HIT-HY
150 MAX-SD have been set to phase-out status.
The Hilti HIT-HY 200 Adhesive Anchoring System is a fast cure adhesive with superior
load performance, flexible working times, and offers Contractors improved installation
reliability. The Hilti Safe Set Technology eliminates the most load-effecting and timeconsuming step in the installation process: cleaning the hole before injection of the
adhesive.
In the majority of concrete anchoring applications, the HIT-HY 200 Adhesive has
equivalent or higher published load values compared to the HIT-HY 150 MAX or HITHY 150 MAX-SD products. For your reference, the attached published load capacity
tables provide a comparison of these three adhesive anchoring systems in three different
uses: uncracked concrete, cracked concrete, and seismic.
For additional technical information, please refer to the HIT-HY 200 Technical
Supplement or download a free copy of the Hilti PROFIS Anchor software.
Additional HIT HY-200 technical information:
Hilti PROFIS Anchor software:

www.us.hilti.com/hy200
www.us.hilti.com/profis

Our engineering support team is available to answer any additional questions you may
have at (800) 879-8000.
Regards,
Business Unit Anchors
Hilti North America

Attachment: Comparison Tables

Reference Load Capacity Tables for HY200 versus HY150 MAX and HY150 MAX-SD

Uncracked Concrete

Diameter (in )

3/8

1/2

5/8

3/4

7/8

1 1/4

Embedment (in ) Note 3

Cracked Concrete

HY200

HY150 MAX

HY150 MAX-SD

HY200

HY150 MAX-SD

Load (lb )

Load (lb )

Load (lb )

Load (lb )

Load (lb )

Seismic/Cracked Concrete
HY200
Load (lb )

3.375

3653

3653

3653

2699

1799

4.5

3653

3653

3653

3599

2398

7.5

3653

3653

3653

3653

3653

2.75

4499

4499

4499

2952

4.5

6688

6688

6688

4830

6688

6688

6688

6441

HY150 MAX-SD

see note 2

Load (lb )

648

864

1439

2142

3506

see note 2

540

720

1199

708

643

1159

1052

4674

1546

1402

10

6688

6688

6688

6688

6688

2576

2337

3.125

5450

5450

5450

3861

3274

1012

982

5.625

10650

10650

10650

7591

5894

1822

1768

7.5

10650

10650

10650

10121

7859

2429

2358

12.5

10650

10650

10650

10650

10650

4048

3929

3.5

6460

6460

6460

4576

4576

1367

1373

6.75

15762

15762

15762

10982

9108

2636

2732

15762

15762

15762

14643

12143

3514

3643

15

15762

15762

15762

15762

15762

5857

6072

3.5

6460

7268

7268

4576

4576

1373

1373

7.875

21755

21755

21755

12668

12509

3800

3753

10.5

21755

21755

21755

16891

16679

5067

5004

17.5

21755

21755

21755

21755

21755

8445

8339

7893

8880

8880

5591

5591

1677

1677

26639

28465

26465

16619

16467

4986

4940

12

28541

28541

28541

22159

21956

6648

6587

20

28541

28541

28541

28541

28541

11080

10978

11031

12689

7814

2344

11.25

37229

28550

26140

7842

15

45669

38067

34854

10456

25

45669

45669

45669

17427

NOTES:
1. Load capacity for a single carbon steel HAS threaded rod with no edge restrictions and no limit on concrete thickness in accordance with ACI 318-08.
2. Seismic load values include 0.4 reduction per ACI 318-08 Part D.3.3.6.
2. Concrete compressive strength = 4000 psi.
3. Embedment depths correspond to: h ef, min , 9da ,12d a , 20d a .
4. Tension failure modes are color coded as follows:

S
C
B

steel failure
concrete breakout
bond failure

Reference Load Capacity Tables for HY200 versus HY150 MAX and HY150 MAX-SD

Uncracked Concrete

Diameter (in )

#3

#4

#5

#6

#7

#8

#9

#10

Embedment (in )

Note 3

Cracked Concrete

HY200

HY150 MAX

HY150 MAX-SD

HY200

HY150 MAX-SD

Load (lb )

Load (lb )

Load (lb )

Load (lb )

Load (lb )

Seismic/Cracked Concrete
HY200
Load (lb )

HY150 MAX-SD

see note 2

Load (lb )

see note 2

3.375

4294

3334

3334

2699

1799

648

540

4.5

5726

4445

4445

3599

2398

864

720

7.5

6435

6435

6435

5998

3997

1439

1199

4.5

7634

5927

5927

4830

3506

1159

1052

10179

7903

7903

6441

4674

1546

1402

10

11700

11700

11700

10734

7790

2576

2337

5.625

11028

9261

9261

7591

5894

1822

1768

7.5

15904

12348

12348

10121

7859

2429

2358

18135

16868

13098

4048

3929

12.5

18135

18135

6.75

17177

13336

13336

10982

9108

2636

2732

22902

17781

17781

14643

12143

3514

3643

25740

24405

20239

5857

6072

15

25740

25740

7.875

21804
31172

18151

18151

126668

12509

3040

3753

24202

24202

16891

16679

4054

5004

35100

28151

27798

6756

8339

10.5
17.5

35100

35100

26639
40715

23708

23708

16619

16467

3989

4940

12

31611

31611

22159

21956

5318

6587

20

46215

46215

46215

36932

36593

8864

10978

10.125

31787

25389

21127

5070

13.5

48939

33852

28169

6761

22.5

58500

56420

46949

11268

26140

6274

11.25

37229

30996

15

57318

41793

34854

8365

25

74295

69655

58089

13941

NOTES:
1. Load capacity for a single ASTM A 615, Gr. 60 reinforcing bar with no edge restrictions and no limit on concrete thickness in accordance with ACI 318-08.
2. Seismic load values include 0.4 reduction per ACI 318-08 Part D.3.3.6.
2. Concrete compressive strength = 4000 psi.
3. Embedment depths correspond to: h ef, min , 9da ,12d a , 20d a .
4. Tension failure modes are color coded as follows:

S
C
B

steel failure
concrete breakout
bond failure