You are on page 1of 0

Page1of21

User RequirementSpecificationsfor
AdvancedTrafficManagementSystemEquipments

1.CCTVCameras
The Closed Circuit Television (CCTV) Surveillance shall comprise video camera, its housing and
pan, and Tilt Heads. The video camera shall be mounted at a height so as to cover the target
length of highway and the housing shall be able to withstand adverse weather conditions. It
shall have a 360 degree angular travel in the horizontal plane and a tilt of 90 degrees down
from 0 degrees horizontal. It shall have zoom lens with minimum power of 30 X, auto iris and
infrared filter, infrared compatibility for night operation and remotely selectable operating
modes.Itshallhavecompatibilitywithcoaxialcable/opticalfibrecable.

TheCCTVcamerashallhavethefollowingminimumfeatures/capabilities:

1. SuitabledesigntoprovideabsolutePTZperformanceandextremeweatheroperability
2. Ruggedizedvandalproofhousingtodeliverperformanceinharshconditions,
3. Viewingrangeof1kmradius,
4. TiltRangeof90downfrom0Horizontal&360angulartravelinthehorizontalplane.
5. DaynightIRfilterforbrilliantdaytimecolourandexcellentnightvisionunderlowlight
andinfraredillumination
6. Totalzoom300X(30Xoptical,10Xdigital)
7. ClosedloopspeedcontrolwithIntegralpan/tiltmotordrivetoenablesmooth,precise
pantiltforfinecontrolandaccuratetracking,evenathighzoomlevels
8. Flatglasswindowwithwiperandinternalheaterforbetteropticalperformanceinrainy,
humidenvironments
9. Waterproof,weathersealedandcorrosionresistant
10. ImageSensor:1/4colourCCD
11. HorizontalResolution:525TVlines
12. Sensitivity:0.01Luxorsuitableforhighwayapplicationinnight
13. Resolution:NTSC/PAL
14. MinimumIllumination0.7Lux@F1.4|ZeroLuxunderIRillumination
15. Focussystem:Autoandmanualfocus
16. CommunicationRS485/RS422
17. BaseMountingoptions
18. ThecompletefieldcameraunitshallbeIP66rated
19. 1ChannelVideoServer
Page2of21

20. NetworkVideoRecorderwith6TBstorage
21. Poleandmounting

a.GUI(GraphicalUserInterface)

The CCT GUI enables the field camera units to be managed by the operator efficiently and
effectively.ThesameGUIalsoprovidesthesupervisorycontrolandmanagementreportfacility.
TheGUIshallbedividedintotwoscreenareas:
1. Videofeeds
2. EventStatusarea
Thesize,shapeandlocationofthetwoscreenareasshallbeadjustable.
Thelabelingoflocationsofthefieldcameraunitisprogrammableatsysteminstallationstage,
duringsystemcommissioning.Thelocationscanhaveaspecificnamerelatingtotheirarea.

b.Function

TheCCTforCCTVsystemmustoperateinaccordancetothefollowingrequirements:
1. Displaytheeventsthatareloggedonacontinuousbasis
2. Alldataandgeneralalarmconditionsmustbeloggedtoadatabase.
3. Databasemusthavequeryfacilities
4. Storagecapacityforallalarmmessages,three(3)yearsatanypointintime
5. Storagecapacityforvideoinformation,with6TBstorage.6. The CCTVCCT should
onaregularbasis,logeventofanyproblemforeachindividualfieldcameraunitinthe
CCTasaneventlog.

2.VMSSPECIFICATIONS(HARDWARE)

ThedesignfortheVariableMessageSigns(VMS)willbemodularwithsignpanelsusingLEDsI
HighGainTransReflectiveLCDsforoutdoorambientlights.Thesignpanelshouldbesuchthat
adisplayislegiblefromadistanceofabout200m.Forthispurpose,panelsshallhaveminimum
dimensions of 3m length x 1.8 m depth. The minimum height of the characters shall be 300
mm.Thecontrastratioshallbemorethan30perpendiculartotheboldfaceandmorethan10
at an angle of 70 degrees to the perpendicular. The equipment shall be capable of storing
minimum10framesthatcanbetriggeredonreceivingthetelecommand.Thesignpanelsshall
be installed on the structure in such a manner that they are aesthetically pleasing and can
Page3of21

withstand wind pressures. The equipment shall be capable of storing minimum semiduplex
modeandotherknownforces.TheminimumverticalclearanceavailableatVMSsshallbe6.0m
fromtheroadsurface.Powersupplyshallbefedfromtheintegratorlocations.

Gantry T Type for both side VMS board (text + Graphics) detailed
specifications

Parameters Details

Dimensions 1800(H)X3000(W)X225(D)mm(DisplayAreaFull
Matrix,
Housing Enclosure:AlMg3/MSplate3mmthickness
Frontplate:AlMg3/MSplate3mmthickness
Housingcoating:electrostaticpowdercoating
(basedonpolyester)
Frontpanelcoating:lowreflectionblackmatt
paint
Servicedoors:AlMg3/MSplate2mm
thickness;
Lockingsystem:quarterturnlockingsystem
Earthing:EathingwithCopperStrip
Protectionlevel IP55(minimum)
WeatherProofing:CENELECEN60529:1991:Degrees
ofprotectionprovidedbyenclosure(IPcode)(IEC529:
1989).Allenclosuresexposedtotheelementsshallbe
protectedtoIP65intermsofthisstandard

Displayarea Textarea:
Pitch:25mm

Resolution:56(H)X128(W)Pixels

DisplayArea:1800x3000mm

CharacterSize:14X7font=350x175mm,16
characters/linex3lines/Frame

Candisplaytext&graphics&animations

Color:Amber

Page4of21

VMSdisplayarea:

Pitch:25mm(basicmoduleis8x16pixels)

Resolution:72(H)X48(W)Pixels

DisplayArea:1800x1200mm

Candisplaytext&graphics&animations

Color:Amber

Supportformultilanguages Userdefinedfonts,English,Hindi

OperatingModes CentralControlSystemandLocalComputer

MessageStorage Upto10messagesof30characterslengthin
thelocalsystemmemory.
Upto10pictograminthelocalsystem
memory
ControllerAddressing Itshallbepossibletochangetheaddressofalltype
ofVMSthroughsoftwareonly
Differentmessagesshallbedisplayedseparatelyon
bothsides.

MessageDisplay Themessagesshallbesent/triggeredtobe
displayedthroughoneofthefollowing
methods:

DownloadthroughControlCentrecomputer
Byreceivingcommandtodisplaylocally
storedtextandgraphicsfromControlCentre
computer
Downloadthroughlocalcomputer(laptop)
Receivingcommandtodisplaylocallystored
textandgraphicsfromlocalcomputer(lap
top)

CommunicationInterface RS232&RS485&Ethernet

CommunicationProtocol CIP,TLSorDGT

ReceivingInput Acceptingmessagesfordisplayorstorein
Memory
Page5of21

Writinganymessagesataneffectiverateof
60characters/second
Blankingofcompletesign

DisplayDriver Displaydrivershallbecapableofdriving3linesof
10characterseachandapictogramwithatleast
90%uniformbrightnesslevelthroughouttheboard

Responsestoinput TheVMScontrollershallacknowledgeafter
receivinganyinputfromcontrolroom/local
computer

ServicePort LocalinVMS

Wirelessport BluetoothinterfaceonVMS

Intensityregulation 0100%continuous

LEDagingcompensation AutomaticLEDcurrentincreaseoverproductlifeto
maintaindesiredbrightness

PowerSupply AC230(15%...+10%)50Hz

PowerConsumption About1200W

Standards ShouldcomplyEN12966:2005

Lightintensity L2minimum

Color C2

BeamWidth B2
Luminanceatangles7horizontallyand5
vertically
minimum50%ofzeroangleintensity

ContrastRatio Thecontrastratioshallbemorethan30
perpendiculartotheboldfaceandmorethan10at
anangleof70degreestotheperpendicular.

Visibility Thesignpanelshouldbesuchthatadisplayis
legibleclearlyfromadistanceofabout200meven
infoggycondition.

Page6of21

LEDtype 5mmultrabrightLEDs

Opticalproperties AccordingtoEN12966:2005
L3(T)(*),R2R3,C2,B1B7
LED TestOptiontoglowallLEDatatimefortestingof
anyLEDfailure

LEDFailureDetection ShouldbeabletotestfailureofeachLED,minimum
3timesaday.

LEDmakes CREE,Osram,Nichia,AvagoUS

BackgroundandUVResistance Thedisplaybackgroundshallbenonreflectiveand
thedisplayshallbeU.V.resistant

WindPressure Shouldbeabletowithstandwindpressuresfrom
gustsofupto150kmperhour

TamperIndicator Duetothefactthattheequipmentismountedin
theopen,itmaybesubjectedtovandalism.A
tamperswitchwithadjustablesensitivityshouldbe
fittedineachVMS

Ambienttemperaturerange T1,T2,T3(40Cto+60C)

ProductLifeTime 10yearsminimum

ApprovedMakes Ortana/Telegra/Imago/ATT

FunctionalSpecifications

ParameterDefault ValueOther Possibilities

Picturethatwillbe
displayedafterVMS
RESET
VMSwillbeoffblank
picture
1.Anyofprogrammed
Pictures
2.Lastdisplayedpicture

Picturethatwillbe
displayedincaseof
communicationfailurewith
controldevice
(e.g.RoadsideCabinet)
VMSwillbeoffblank
picture
1.Anyofprogrammed
Pictures
2.Noreaction
Page7of21

VMSstateincaseof
communicationloss
betweenoneormoredriver
modulesandcontroller
module

VMSwillbeoffblank
picture
VMSwillstayON
Periodoftimeafterwhich
VMSwillsetdefinedpicture
incaseofcommunication
failure

Max.3minutes Anyvaluefrom10sec.to
severalhours(Max.9
hours.)

VMSGUI
The CCT GUI enables the remote VMSs to be managed by the operator efficiently and
effectively.ThesameGUIalsoprovidesthesupervisorycontrolandmanagementreportfacility.
TheGUIshallbedividedintothreescreenareas:
Commandbar
Maparea
Eventstatusarea

Thesize,shapeandlocationofthetwoscreenareasshallbeadjustable.

ThelabellingofzonesandtheVMSunitsareprogrammableatsysteminstallationstage,during
systemcommissioning.ThezonescanhaveaspecificnamerelatingtotheirareaandVMSscan
beidentifiedusingalphanumericcodes.

VMSGUIFunctions

TheCCT(ATMSSCADA)forVMSsoperatesinaccordancetothefollowingrequirements:

Thesolutionshallbeconfigurablebycustomer,i.e.addition/deletionofVMS,changing
locationofVMS,importing/modifyingpictograms,multilanguages.
The solution should provide quick customization. Any Change Request should be
implementedin10daysfromthedateofChangeRequestDocument.
OperationviatheCCTkeyboard.
ChangeofdisplaymessageofVMSandgroupofVMS.
Enteringthereasonofchangingdisplaytononstandard(nonpreset)textmessage,or
symbolandwhythatwasnecessary.
OncetheVMSmessageischanged,itshallbeindicatedattheVMSCCTontheGraphical
UserInterface(GUI)display,withtheVMSiconchangingitscolour.
Page8of21

ThedateandtimeofmessagechangeshallberegisteredontheVMSCCT
Databasemusthaveexhaustivequeryfacilities.
Storagecapacityformaintainingalleventandincidentsshallbeaminimumofthree(3)
yearsatanypointintime.
TheVMSCCTshouldonaregularbasistesteachindividualVMSsexhaustivelytotestfor
correct operation. In the event of any problem, it shall be reported by the CCT
accompaniedbyaneventlogandthecolouroffaultyVMStobechangedtored.
Optiontoglow/blankingofallLEDatatimefortestingofanyLEDfailure.

VMSRoadUserrequirements
The VMS shall provide an alphanumeric or graphical pattern or both display to the road user,
visiblefromadistanceofapproximately200metres(eveninfoggycondition).Messagescanbe
displayedintheformofanalphanumericsequence,consistingofthreelinesofHindiorEnglish
charactersand/orgraphics.

VMSSecurity
The VMS shall contain access door open detector switch sensor at all its doors. When any of
thesesensorsdetectsactivity,alocalaudiblealarmshallsoundinthenearbySubcentreanda
message alarm shall be sent to the VMSCCT in the control room to alert the Central Control
Roomoperatoraboutsuspectedtampering.
Locking arrangement shall require a special tool to access electronic compartment of VMS. It
shallnotbepossibletonormallyopen(withoutanydamagetotheenclosure)theVMScabinet
withoutthisspecialtool.

3EmergencyCallBox(ECB)
Emergency call boxes (ECBs) with loud speaker, micro phone, activation button with LED
indicating conversation, shall be housed in a vandal proof casing and operate in full to play
modeinnoiselevelofupto95decibelswithinbuiltdiagnosticfeaturesforautomaticdetection
incaseofdamagebyanyobject.

ECBMasterUnit
TheMasterECBstructureshallconsistofalockabledoorforaccessingthefollowing:
theloudspeaker,
themicrophone,
thepushbutton(builtinwiththestructure),
LEDindicator,
theprocessingelectronics,
thebatterypackwith48hoursbackup(MountedatthetopoftheECBpostwithlock&
keyarrangement)
Page9of21

thesolarpaneltomeetthepowerrequirementofthecompleteECBunitsupplyingthe
electronics,(shallbemountedatleast3.5mabovebottomlevelofECBpost)and
theterminationassemblytoconnecttotheSlaveECBunit.

ECBSlaveUnit
TheSlaveECBstructureshallconsistofalockabledoorforaccessingthefollowing:
theloudspeaker,
themicrophone,
thepushbutton(builtinwiththestructure),
LEDindicator,and
theterminationassemblytoconnecttotheMasterECBunit.

ECBHousing
ThehousingshallbeyellowcolourpowdercoatedMildsteel.ColouroftheECBhousingshallbe
chosensuchthatitshallmatchtothehousingandisprominentandeasilyrecognizablebythe
users.

ECBRedundancyScheme
Redundancyshallbemaintainedinsuchamannerthatasinglefibercore/coppercable
failure or single ECB unit failure shall not affect the normal operation of the other ECB
unitsandControlRoomfunctionality.
In case of since ECB failure, it should not affect the functionality and communication
withCCTforotherECBs.

ECBTechnicalSpecifications
a)Speaker
TypeWaterresistant
MaxPower15W
Impedance8ohm15%
Bandwidth:40Hzto8KHz
ECBinterfaceoutputPower:0to6W
b)Microphone
TypeDynamicmicrophone
Sensitivity:1.9mV+/3dB/Pa
Page10of21

Impedance200ohms
InputlevelatECBinterface:20to50dBm
c)EnvironmentalSpecifications
Waterproofboxforundergroundcabinet:prooflevelIP67
WeatherresistanttoIP67standard
Operatingtemperature:10to+60C
LighteningprotectiontoITUTrecommendationK.21
Relativehumidity:10%~75%(noncondensing)
Maximumwindspeed:150km/h
d)EMCstandards:
EN500811EN500812
EN500821EN500822
EN55022

4.METSPECIFICATIONS
The meteorological sensors shall comprise thermocouple /pyrometer, humidity meter,
anemometer, visibility meter and sensor for measuring pavement surface temperature. They
shall be installed on a single pole with a specific attachment and power supply fed from the
integrator. They shall have the facility to communicate on Polythene Insulated Jelly Filled
coppercables(PIJF)/OpticalFibreCable.

METSystemConfiguration
METsystemshallconsistofthefollowingweathersensorsandcomponents;
1 Ambienttemperaturesensor+0.3C
2 WindSpeed&Directionsensor+1.0m/s
3 RoadSurfacetemperaturesensor+0.2C
4 RelativeHumiditysensor
5 Visibilitysensor+15%
6 Datalogger
7 Solarpanel&Battery
8 NEMA4Enclosure&mastaccessories
Page11of21

9 Cableandaccessoriesrequiredincontrolcentre
10ThesystemshallbeinstalledonsinglesteadyG.I.pipewithoutuseofstay/guycables.
11Chainlinkfencing(2.5mheight)alongwithantiintrusionbarbedwirecoilsmountedon
topshallbeprovidedwithentrygate.

METAmbienttemperaturesensor
The temperature sensor shall incorporate thermolinear network consisting of resistors and
precise thermistors which shall produce an output voltage linear with the temperature. The
thermistornetworkshallbeembeddedinatubewithcoolingribs.Thesensorshallbeequipped
witharadiationscreenthatshallhinderheatingofthesensorbydirectsunshine.
Thesensorcanbeusedoutsidethespecifiedtemperaturerangewithreducedaccuracy.

METWindSpeed&Directionsensor
Thewindspeedsensorshallhaveathreecupshelicoidspropellerandthewinddirectionsensor
shall be rugged lightweight vane with a sufficient low aspect ratio to assure good fidelity in
fluctuatingwindconditions.

Wind speed shall be measured by AC sine wave voltage signal with frequency which is
producedduetorotationofpropeller,whichisdirectlyproportionaltothewindspeed.

Winddirectionsensorsvaneangleshallbesensedbyaprecisionpotentiometerhousedina
sealedchamber.Withaknownappliedvoltagetothepotentiometer,theoutputvoltageshall
bedirectlyproportionaltothevaneangle.
TheinstrumentshallbemadeofUVstabilizedplasticwithstainlesssteelandaluminumfittings.
Precisiongrade,stainlesssteelballbearingshallbeused.
A mounting orientation ring shall be available to assure correct realignment of the wind
directionreferencewhentheinstrumentisremovedformaintenance.

METRoadSurfacetemperaturesensor
Thesensormustbeinstalledflushwiththeroadsurfaceandoutsidethewheelpathwherethe
water will not accumulate. The sensor shall be worn down with the surrounding road surface
andshallbepoweredbythedatalogger.
Page12of21

METRelativeHumiditysensor
The humidity sensor circuit shall have a linear output voltage between 0 to 100% relative
humidity.

METVisibilitymeasurementsensor
Itshallmeasureatmosphericvisibilitybydeterminingtheamountoflightscatteredbyparticles
(smoke,dust,fog,rainandsnowetc.)intheairthatpassesthroughthesamplevolume.

METDatalogger
TheDataloggerandsoftwareshallprovidethefollowingminimumfunctions:
1. TheDataloggershallhavethefacilitytocommunicateonOpticalfibercable.
2. Itshallbecompact,ruggedindesignandhavingeaseofmaintenance
3. Itshallbecapableofdetectingandkeepingtrackofthevariousclimaticparameterson
thehighwayandinitiateappropriatealarmsattheControlCentre.
4. Performweatherdatacollection,datastorageandtransfertocontrolcentre.
5. Insertsequencenumbersforeachdatarecords.
6. The Data logger shall be of modular design to aid in system maintenance,
troubleshootingandinfieldservicing.
7. All components of the Data logger, including sensors, shall contain necessary electrical
protectiontopreventdamagefromelectricalsurges,spikesandtheeffectsoflightning.
8. The Data logger shall be of durable, industrial design and construction and enable
continuous operation, with automated startup in the event of power outage and
restoration.
9. AllsensorandancillaryequipmentconnectionsshallbeconvenientlylocatedintheData
loggerfrontpanel.Allconnections,wherepossible,shallbeplugin,quickconnectstyle.
10. AllACpowerconnectionsshallbeshieldedtopreventelectricalshock.
11. LEDstatusindicatorforcorrect/faultyoperationofDatalogger,withdifferentcolours.
12. Communication
a. OnboardEthernetinterface
b. TwoRS232interface
13. Storage
Page13of21

a. Nonvolatile local storage to prevent data loss during power outages preferably
basedonflashmemory.
14. Enclosure
a. IP66rated
b. Powdercoated

5.ATCCSPECIFICATIONS(TECHNICAL)
TheAutomaticTrafficCountercumClassifier(ATCC)shallbecapableofdetectingandrecording
all,categoriesofvehiclesplyingontheProjectHighway(Sixlane)basedontheirlengthandno.
ofaxles.Thesystemshallberobustandcapableofoperatingwithminimummaintenanceand
may be either piezoelectric or infrared. It should have minimum accuracy level of 99%. The
logic units shall be microprocessor based. The system should be able to record and store
vehicle data for a period of at least two weeks with a Daily Traffic Volume of up to 1,00,000
vehicles.ThesystemshallhavecompatibilitytotransferthedataonPIJF/OpticalFibreCable/by
using any of the available communication mode like GSM (Global System ' for Mobile
Communications)/GPRS(GeneralPacketRadioService),landlinemodem,CDMA(CodeDivision
MultipleAccess)dependingupontheeffectiveandeconomicoperationoftheparticularmode
available at the site. The system shall be electric/solar power operated depending upon the
availabilityofsource.

TheATCCsystemshallconsistofapiezolooppiezoconfigurationinatrafficlane,withasquare
orrectangularlooptoensurepropercoverageofthelanewidthsystematicallyplacedbetween
thepiezosensors.
Suppliershallproposeanyotherconfiguration,ifrequired,forbetterresults.

ATCCFeatures
Activelightningprotection.
Flexibleconfiguration.
Digitalchassisheightdetection.
Coincidencedetection(lanestraddle).
Tidalflowandreversedirectionrecording.
Comprehensivesystemperformancemonitoring.
Detailsensordiagnosticscapability.
Userfriendlysetupandcompletediagnostics.
Page14of21

Provisionformostpopulardataformats.
Usermodifiableparametersets.
Comprehensivesoftwaresupport.
Lowpowerconsumption(solarchargingsupported).

ATCCComponents
TheATCCSystemshallconsistofthefollowingsystemcomponents:
A. PiezoSensorsforaxlecounting(ClassII6'BLPiezoSensorw/100'LeadIn)
B. VehicleDetectorLoop
C. ATCCControlleranditsenclosure
D. InbuiltPowerbackup
E. VEHICLETRAFFICCLASSIFIERupto6LanesConsistingofRoadsideElectronicsMicroprocessor
based,Complete1MBmemory,whichissuitableforoursurveys.16KeywatertightKeyboard
anddisplay,withinputforinductiveLoopSensorswithfield
F. UPP9PinSerialCable6'
G. PU200/SPIEZOINSTALLATIONRESIN
H. UPPPowerSupplyAC/DC
I. CenturionStandardSoftware(Windowsbased)ORequivalent
J. WorkStationforATCC
K. UPPLNPCLoopCable
L. LoopCablewithLoopFiller
M. MiscellaneousitemsrequiredinInstallation

ATCCAxlecounter
The axle counting sensors shall consist of two independent Piezoelectric Sensors of different
lengthacrossatravellane,enablingdetectionofaxlesofallvehiclecategories.
Two piezo sensors with difference in lengths by 1:2 ratio shall be installed in opposite
arrangement to its previous or next piezo sensor row of a lane, so that the system can easily
differentiatebetweenanaxlewithtwowheels(normalaxle)andanaxlehavingonlyonewheel
(motorbikeaxle).
To protect from heavy traffic, the sensor shall be covered with a minimum of 10 mm resin
belowthesurfaceoftheroadandtheresinoftheinstalledsensorshallhaveminimumlifespan
of5years.
Page15of21

Thetemperaturerangesofpavementsinwhichthesensorshallworkare40Cto+80C.

ATCCVehicleDetectorLoop
VehicleDetectorLoopshallbesquareorrectangularinshapetoensurepropercoverageofthe
lanewidthandshallbeplacedsystematicallybetweenthepiezosensors.
Loopdetectorsshallbeprovidedforinterfacetothesedetectorloops.Loopdetectorsshallbe
installedintheATCCControllercabinet.
Detector loop shall be of readymade type with minimum of 4 turns of AWG #18 wire,
encapsulated in a protective PVC jacket. Loops shall be spliced to the shielded twisted leadin
cableinajunctionboxpriortotheequipmentcabinet,ifrequired.Suppliershallavoidsplicing/
jointinleadincableasmuchaspossible.However,ifjointingisrequired,thejointsshallnotbe
buried,orcoveredwithepoxyintheroadorshoulderarea.
Loops and leadin cables shall be tested in reference to earth ground with a Megger and
resistanceshallbegreaterthan200megaohms.Theloopshallbecheckedforinductanceand
shallmeettheloopamplifiermanufacturesspecification.
Thetemperaturerangesofpavementsinwhichtheloopsshallworkare40Cto+80C.
ATCCController
ThespecificationsfortheATCCControllerareasfollows:
A. Communication
Controllerareanetworkbusdesignforoptiontoaddsensorinterfaceboards.
OnboardEthernetinterface
TwoRS232interface
RemoteadministrationviaTelnetorwebbasedprogram
Remotefiledownload
B.Storage
Nonvolatilelocalstorageforvehicleinformationtopreventdatalossduringpower
outages
C.Software
Shallbecapableofsimultaneousprocessingof6lanesoftrafficdata.
Userdefinableclassificationschemeandparameters.
D.Localuserinterface
DisplaywithapplicationspecificKeypad
Page16of21

E.Enclosure
19rackmount
Powdercoated
IP66rated

ATCCPowerbackup
Capable of feeding power to ATCC Controller, to perform its full function up to 48 hours of
continuouspoweroutage.

ATCCGeneralRequirements
TheATCCControllerandsoftwareshallprovidethefollowingminimumfunctions:
A. Therecordinganddisplayunitshallworkaccuratelybetween200Cto+600C.
B. Performdatacollection,datastorage,filemanagementandreportgenerationfunctions
forcollectedvehicleinformation.
C. Insertsequencenumbersforvehiclerecords.
D. The Controller shall provide a facility for viewing current vehicle records of a single or
multiplelaneandsensordiagnosticsdirectly,withoutanyancillaryequipment.
E. The Controller system shall be of modular design to aid in system maintenance,
troubleshootingandinfieldservicing.
F. All components of the Controller, including inductive loop detectors, shall contain
necessaryelectricalprotectiontopreventdamagefromelectricalsurges,spikesandthe
effectsoflightning.
G. The Controller shall be of durable, industrial design and construction and enable
continuous operation, with automated startup in the event of power outage and
restoration.
H. All sensor and ancillary equipment connections shall be conveniently located in the
Controller front panel. All connections, where possible, shall be plugin, quick connect
style.
I. All wires from axle sensors, loops, data transmission lines etc shall be terminated on
separateterminalsinsidetheATCCController,foreasyremovalofcontrollerelectronics
during maintenance. The terminals shall be identified by terminal number. These
terminalsshallbeeasilyaccessible.Allcablesshallbelongenoughtoeasilyreachthese
terminals. Terminals, splices, or any other type of connections prior to these terminals
shallnotbeallowedexceptforsplicingofalooptoashieldedtwistedloopleadincable.
Page17of21

J. AllACpowerconnectionsshallbeshieldedtopreventelectricalshock.
K. Free space in the bottom of the cabinet shall be a minimum of 12 inches to allow the
pulling of cables without removing any equipment. The Controller shall be set on
shelves or mounted with support bracket underneath. The arrangement shall provide
easyaccesstothekeypadandviewofthedisplay.
LEDstatusindicatorforcorrect/faultyoperationofATCCController,withdifferentcolours
PavementQualityconcreteforATCCshallbeexecutedbyMRMPL.

6.MobileCommunicationSystem(MCS)
Will be provided by using GSM/CDMA Mobile phones by the client. Only interfacing with ECB
systemshallbeincludedinscopeofworkofAgency.

7.ControlCentre
CentralControlRoom(ControlCentre):TheCentralControlRoom(CCR)shallbetherepository
of all the data acquired from the field and their processing, storing, and archiving. All the
informationforrealtimemonitoringoftheProjectHighwayshallbegeneratedattheCCRand
the relevant information shall be disseminated to the users through Variable message signs,
andtotheoperationandmanagementteamsthroughmobileradiocommunicationsystemfor
appropriate intervention. Another important function to be performed at the Control centre
shallbetheoperationandmanagementoftheATMSitselfalongwithitsvarioussubsystems.
CCRshallhavethefollowingminimumequipment,hardwareandsoftware:
1. ACentralComputerServerwithintegratedATMSandATMSsoftware(SCADA)
2. ATrafficManager'sTerminalforoperationoftheintegratedtrafficmanagementsystem
3. CallsystemequipmentcomprisingOperatorPCalongwithsubsystemsanddigitalvoice
recorder.
4. MobileradioterminalcomprisingOperatorPCandengineeringterminal
5. Computers for Network Management Systems (NMS) for Fiber Optic Communication
System.
6. CCTVConsoleEquipment
7. ComputersforVMS,AVCC,MET,TrafficControl
8. Alargesizescreen(VideoWall)
9. AlinePrinter
10. APowerSupplyandbackupsystem
Page18of21

ControlCenterComponents
TheControlCentershallconsistofthefollowingsystemcomponents:
a. Server with Windows 7 OS and Oracle database, RAID 5 with 17" TFT, Keyboard and
mouse
b. Administratorworkstation
c. 120"VideoWall
d. Rack42"formountingServerandotherequipments
e. Printer
f. PowerCable&LaneCable
g. Computers for Network Management Systems (NMS) for Fiber Optic Communication
System.
h. ComputersforVMS,AVCC,MET,TrafficControl
i. Min6KVAUPSwithonehourbackup.shallbeasperactualrequirements+30%
j. NetworkSwitch16Port
k. CablingWork

Notes:
1) All equipments & components shall be safe guarded against power fluctuation as per
prevailingconditionofGujarat&Maharashtra.
2) NecessaryOFCductwillbelaidinmedianonlywithHDPEpipe.
3) Warrantyfortheequipmentssuppliedandinstalledwillbefor24monthsfromthedate
ofsatisfactorycommissioningofthesystem.
4) The work will be completely on turnkey basis. Civil work of control room with power
supplyatonelocationinthecontrolroomshallbeprovidedbyMRMPL.Powersupplyfor
functioning of equipment (excluding ECBs) along the project length at predetermined
locations at outer edge of carriageway shall be provided by MRMPL. Rating of power
requirement for all such locations will have to be specified by successful bidder
specifically.
5) Thescopeofworkshallalsoincludeallsuchitemswhicharenotspecificallymentioned
inthescope,butwhicharenecessaryforthesatisfactorycompletionoftheentirescope
of work unless otherwise specifically excluded from the scope. Any crossing of
constructedroadshallbethroughpipelaidbytrenchlesstechnology.
Page19of21

BillofQuantities
Sr.
No.
Description Unit Quantity
1 Providing&installationofCCTVSystems
includingPTZvideocameras,itshousingand
pan,andTiltheads,Pole&Mounting,Channel
VideoServer,NetworkVideoRecorderwith6
TBstorageincludingalltherequired
peripherals,allleads&lifts,transportation,
material,manpower,taxes(includingWCT,VAT
&Servicetax)etc.completeonturnkeybasisas
perattachedUserrequirementspecifications
forAdvancedTrafficManagementSystem
Equipments&instructionofAuthorized
representativeofMRMPL.
No. 10
2 Providing&installationofVariableMessage
Signs(VMS)SystemsforText&Graphics
includingTtypeGantryforbothsideVMS
boardofsize1800(H)X3000(W)x225(D)mm
(Displayareafullareamatrix),VMSSoftware,
CopperStripforEarthing,Datacable,Power
cable,VMSWorkstation,ControlCenter
Cablingincludingalltherequiredperipherals,
allleads&lifts,transportation,material,
manpower,taxes(includingWCT,VAT&
Servicetax)etc.completeonturnkeybasisas
perattachedUserrequirementspecifications
forAdvancedTrafficManagementSystem
Equipments&instructionofAuthorized
representativeofMRMPL.
No. 06
3 Providing&erectionofEmergencyCallBoxes
includingyellowcolourpowdercoatedM.S.
ECBhousing,loudspeaker,microphone,push
button,LEDIndicator,processingelectronics,
batterypackwith48hoursbackup,solarpanel,
terminationassembly,controlroomsoftware,
controlcabling,OFCcablingworkinMedian
includingalltherequiredperipherals,allleads
&lifts,transportation,material,manpower,
taxes(includingWCT,VAT&Servicetax)etc.
completeonturnkeybasisasperattached
UserrequirementspecificationsforAdvanced
No. 240
Page20of21

TrafficManagementSystemEquipments&
instructionofAuthorizedrepresentativeof
MRMPL.
4 Providing&erectionofMETSystemsincluding,
AmbientTemperatureSensor,Windspeedand
directionsensor,Roadsurfacetemperature
sensor,Relativehumiditysensor,Visibility
sensor,Datalogger,Solarpanel&battery,
NEMA4enclosure&mastaccessories,cable
andaccessoriesrequiredincontrolroom,G.I.
pipeformounting,Chainlinkfencing(2.5m
height)alongwithantiintrusionbarbedwire
coilsmountedontopincludingalltherequired
peripherals,allleads&lifts,transportation,
material,manpower,taxes(includingWCT,VAT
&Servicetax)etc.completeonturnkeybasisas
perattachedUserrequirementspecifications
forAdvancedTrafficManagementSystem
Equipments&instructionofAuthorized
representativeofMRMPL.
No. 02
5 Providing&erectionofAutomaticTraffic
CountercumClassifier(ATCC)includingPiezo
Sensorsforaxlecounting,Vehicledetector
loop,ATCCcontrolleranditsenclosure,Inbuilt
Powerbackup,VehicleTrafficclassifier,UPP9
pinSerialCable6,PU200/SPiezoinstallation
resin,UPPPowersupplyAC/DC,ATCCsoftware,
workstationforATCC,UPPLNPCLoopcable,
LoopcablewithLoopfillerincludingallthe
requiredperipherals,allleads&lifts,
transportation,material,manpower,taxes
(includingWCT,VAT&Servicetax)etc.
completeonturnkeybasisasperattached
UserrequirementspecificationsforAdvanced
TrafficManagementSystemEquipments&
instructionofAuthorizedrepresentativeof
MRMPL.
No. 02
6 *MobileCommunicationSystem(MCS):Willbe
providedbyusingGSM/CDMAMobilephones
bytheclient&InterfacingwithECBsystem
includingalltherequiredperipherals,allleads
&lifts,transportation,material,manpower,
No. Nil*
Page21of21

taxes(includingWCT,VAT&Servicetax)etc.
shallbeincludedinscopeofworkofAgency.
7 ControlCentre:IncludesServerwithWindows
7OSandoracledatabase,RAID5with17TFT,
Keyboardandmouse,Administration
workstation,120VideoWall,Rack42for
mountingServerandotherequipments,
Printer,Powercable&LaneCable,Computers
forNetworkManagementSystems(NMS)for
FiberOpticCommunicationSystem,Computers
forVMS,AVCC,MET,TrafficControl,Min6KVA
upswithonehourbackup,NetworkSwitch16
port,Cablingworkincludingalltherequired
peripherals,allleads&lifts,transportation,
material,manpower,taxes(includingWCT,VAT
&Servicetax)etc.completeonturnkeybasisas
perattachedUserrequirementspecifications
forAdvancedTrafficManagementSystem
Equipments&instructionofAuthorized
representativeofMRMPL.
No. 01

*InterfacingwithECBsystemshallbeincludedinscopeofworkofAgency.