Preface
Fujitsu would like to thank you for purchasing our power synchronized unit for the ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage systems. The power synchronized unit is a device that synchronizes power operations of the ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage systems (referred to as "ETERNUS DX S2" in the remainder of this manual) with servers. This manual introduces the user to the power synchronized unit, and explains the regular checks and maintenance that are required. Please carefully review the information outlined in this manual. Sixth Edition March 2012
Applicable Environment
The power synchronized unit was designed and manufactured with user safety for general office environments in mind. When using the power synchronized unit, follow the handling instructions, placement and cautionary notes listed in this manual. If used beyond the limits described, the users may be at risk of personal injury and/or material damage.
3
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Preface
4
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Preface
The power synchronized unit is designed, developed and manufactured as contemplated for general use, including without limitation, general office use, personal use, household use, and ordinary industrial use, but is not designed, developed and manufactured for use in situations with accompanying fatal risks or dangers that, unless extremely high safety is secured, could lead directly to death, personal injury, severe physical damage or other loss (hereinafter "High Safety Required Use"), including without limitation, nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, and missile launch control in weapon systems. Do not use the power synchronized unit for High Safety Required Use without securing the sufficient safety level required. If you wish to use the power synchronized unit for High Safety Required Use, please consult with our sales representative before such use.
The company names, product names and service names mentioned in this document are registered trademarks or trademarks of their respective companies.
Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation.
5
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Preface
6
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 1 Overview
This chapter provides overviews, features, specifications, and system configuration examples of the power synchronized unit. The names and usage of the various components for the power synchronized unit are also described.
Chapter 2 Installation
This chapter describes how to install the power synchronized unit.
Warning Notations
Warning signs are shown throughout this manual in order to prevent injury to the user and/or material damage. These signs are composed of a symbol and a message describing the recommended level of caution. The following section explains the symbols, their levels of caution, and their meanings as used in this manual.
WARNING
This symbol indicates the possibility of serious or fatal injury if the power synchronized unit is not used properly.
7
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
CAUTION
This symbol indicates the possibility of minor or moderate personal injury, as well as damage to the power synchronized unit and/or to other users and their property, if the power synchronized unit is not used properly. This symbol indicates IMPORTANT information for the user to note when using the power synchronized unit.
IMPORTANT
The following symbols are used to indicate the type of warnings or cautions being described.
Electric Shock
The triangle emphasizes the urgency of the WARNING and CAUTION contents. Inside the triangle and above it are details concerning the symbol (e.g. Electrical Shock). The barred "Do Not..." circle warns against certain actions. The action which should be avoided is both illustrated inside the barred circle and written above it (e.g. No Disassembly). The black "Must Do..." circle indicates actions that must be taken. The required action is both illustrated inside the black circle and written above it (e.g. Unplug).
No Disassembly
Unplug
Do
To avoid damaging the power synchronized unit, pay attention to the following points when cleaning the power synchronized unit. - Make sure to disconnect the power when cleaning. - Be careful that no liquid seeps into the power synchronized unit when using cleaners, etc. - Do not use alcohol or other solvents thinners to clean the power synchronized unit.
8
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
9
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Safety Precautions
This section describes safety precautions. Make sure to follow the instructions described below to ensure the safe use of the power synchronized unit.
WARNING
If the AC cable and/or power plug is damaged, do not use the power synchronized unit and contact your sales representative or your maintenance engineer. Never attempt to repair the power synchronized unit by yourself. Not doing so may cause electrical shock or fire.
Unplug
If the power synchronized unit overheats, gives off smoke or an unusual odor, makes an unusual sound, or shakes abnormally, immediately disconnect the power plug from the socket. After the problem has subsided, contact your sales representative or your maintenance engineer. Never attempt to repair the power synchronized unit by yourself. Not doing so may cause electrical shock or fire. If any liquids such as water or foreign objects like metal fragments get into the power synchronized unit, immediately disconnect the power plug from the socket. Then, contact your sales representative or your maintenance engineer. Never attempt to repair the power synchronized unit by yourself. Not doing so may cause electrical shock or fire. If the power synchronized unit is dropped or covers are damaged, immediately disconnect the power plug from the socket. Then, contact your sales representative or your maintenance engineer. Never attempt to repair the power synchronized unit by yourself. Not doing so may cause electrical shock or fire.
10
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Safety Precautions
WARNING
Do not place the power synchronized unit in an area with bad ventilation or where anything that may cause a fire, or flammable gases are generated. Doing so may cause electric shock or fire. Do not place the power synchronized unit in locations subject to oil smoke, steam, humidity and dust, or in places where the power synchronized unit may come into contact with water. Doing so may cause failure, fire, or electric shock. If there is a thunderstorm, do not connect AC cables or any other types of cables. Doing so may cause electric shock or fire. Do not place any objects containing water (vases, cups, etc.) on or near the power synchronized unit. This may cause water to get into the power synchronized unit and damage the power synchronized unit and/or lead to fire or electrical shock. Do not place the power synchronized unit on an unstable floor. The power synchronized unit may fall and be damaged, and cause injury.
Unplug
When the power synchronized unit is installed or moved, disconnect the power plug from the socket. Remove all the connected cables. Watch your step during the operation. Not doing so may damage the AC cable and cause electrical shock or fire. Not doing so may also cause the power synchronized unit to fall and injure others.
CAUTION
Do Not
Do not use the power synchronized unit in an area affected by corrosive gas or in a salty environment. Doing so may cause the power synchronized unit to malfunction. Do not place heavy objects on the power synchronized unit or knock it. Doing so may damage the power synchronized unit or cause injury.
11
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Safety Precautions
CAUTION
Do Not
Do not place the power synchronized unit in areas with strong magnetic fields, such as in the vicinity of TVs or speakers. Doing so may damage the power synchronized unit and cause the power synchronized unit to malfunction. Do not place AC cables and other cables in locations where they may become trip hazards. Doing so may damage the power synchronized unit or cause injury. Do not place the power synchronized unit on a slanted or unstable surface or in areas that tend to shake. Doing so may cause it to tip over and injure others. Also, do not place the power synchronized unit in high traffic areas such as in a hallway. Passersby can shake the unit, damage it or cause incorrect operation.
Temperature
Use the power synchronized unit in an environment in which the ambient temperature is between 5C and 40C. Do not use the power synchronized unit in an environment in which the temperature exceeds 40C or is less than 5C. For 24-hour operation, ensure that the schedule for air conditioning is able to maintain the temperature between 5C and 40C. Not doing so may damage the power synchronized unit. Use the power synchronized unit in an environment in which the humidity is between 20%RH and 80%RH. During the winter, control the heating system to limit ambient temperature rises to less than 15C per hour to prevent condensation. Not doing so may damage the power synchronized unit or cause electrical shock.
WARNING
Never attempt to repair, disassemble, or remodel the power synchronized unit by yourself. Doing so may cause electric shock or fire.
Do Not
Do not use a voltage other than that indicated. Doing so may cause electric shock or fire.
12
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Safety Precautions
Do Not
WARNING
Do not disconnect the power cord plug with wet hands. Doing so may cause electrical shock. Do not put the stress on the root of the AC cable, for example, by twisting it. Doing so may expose or cut the cable core of the AC cable, causing fire or electric shock. Do not damage or modify the AC cable or the power plug. Heating, forced bending, twisting, pulling, or placing heavy objects on the AC cable or the power plug will damage it, causing fire or electrical shock. Do not plug all the AC cables into a single socket. Doing so may cause electric shock or fire. Do not use an AC cable other than one attached, or the one specified. Do not use the attached AC cable or specified AC cable for other devices. Doing so may cause failure, fire, or electric shock. Do not use any products other than the optional products for the power synchronized unit. Doing so may cause failure, fire, or electric shock. Do not insert or drop foreign objects such as metals or flammable objects into openings in the power synchronized unit (air vents, etc.). Doing so may cause failure, fire, or electric shock. Do not obstruct the openings in the power synchronized unit (air vents). Doing so may cause overheating and fire. Do not use any flammable type cleaning sprays. Doing so may cause electric shock or fire.
Do
Use a power cord with ground lead. Using power sockets without ground lead may cause fire, electric shock, or malfunction. If there is a thunderstorm, disconnect the power plug from the socket. Some thunderstorm lead to fire, electrical shock, or malfunction. Ensure the plug is fully inserted into the power socket. Not doing so may cause fire or electrical shock.
13
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Safety Precautions
Do
WARNING
Install optional products for the power synchronized unit by following the instructions described in this manual. If an optional product is installed in any other way, device failure or electrical shock may occur.
Do Not Wet
Do not pour or spill water on the power synchronized unit. Doing so may cause failure, fire, or electric shock.
Unplug
When unplugging the power cord, do not pull on the cable, hold the plug. Pulling the cable may expose or snap the inner wires, which can lead to fire or electrical shock. Use a dry cloth to remove all dust from plugs and power sockets. Not doing so may cause electrical shock or fire. When the power synchronized unit is not used for a long period of time, unplug all power plugs. Not doing so may cause fire.
CAUTION
Do Not
When the power synchronized unit is pulled out from the rack, make sure not to hit your head if you are operating devices under the power synchronized unit. Not doing so may cause injury. Do not put your finger into the socket of the power synchronized unit. Doing so may cause injury. Do not remove the cover from the power synchronized unit socket unless necessary. Doing so may damage the power synchronized unit. Before applying insecticides for pest control, turn off the power synchronized unit and cover it with a plastic sheet. Not doing so may damage the power synchronized unit. Do not use devices such as mobile phones that emit radiation in the vicinity of the power synchronized unit. Doing so may cause a malfunction.
14
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Safety Precautions
When installing the power synchronized unit with other devices into the same rack, the airflow of the device installed on and under the power synchronized unit may interfere with each other and have a damaging effect on device cooling. Make sure to leave plenty of room between the devices if required. Not doing so may damage the power synchronized unit and cause the power synchronized unit to malfunction.
Temperature
Especially for an enclosed rack with doors, or when multiple devices are to be installed and running, the temperature inside the rack will be considerably higher than that of the room. Keep the temperature inside the rack is lower than 40C. Not doing so may damage the power synchronized unit.
Do
When installing the power synchronized unit in a rack, be careful not to pinch your fingers in the rack. Not doing so may cause injury. If no other components are installed, attach the blind panels provided with the rack. Not doing so may damage the power synchronized unit due to improper cooling of the power synchronized unit. When moving a rack that is already installed, make sure to contact your sales representative or maintenance engineer. Do not move a rack by yourself. Doing so may damage the power synchronized unit or cause injury.
15
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Safety Precautions
Handling cables
CAUTION
Do Not
Do not damage or modify the cable such as heating, forced bending, twisting, pulling, or placing heavy objects on them. Doing so may damage the cable and lead to the power synchronized unit malfunction. Do not bend the cable too much or bind it up. Doing so may damage the cable and cause the power synchronized unit to malfunction.
90
Do not bind up
Do
Fully insert cable connectors into inlets, outlets, or sockets. Not doing so may cause the power synchronized unit to malfunction. When unplugging the cable, do not pull on the cord, hold the connector. Not doing so may damage the cable and lead to the power synchronized unit malfunction. Remove any dirt on cable connectors. Not doing so may cause the power synchronized unit malfunction.
16
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Labels
Warning labels and manufacturer's labels are found in various places of the power synchronized unit, as shown in the example below. Never remove these labels from the equipment or allow them to become dirty.
Manufacturers label
Indicates the model, serial number, etc. This label is attached to the plate in the label holder on the bottom of the power synchronized unit. It can be checked by pulling out the plate when the power synchronized unit is installed in a rack.
AC sensor unit
Manufacturers label
Indicates the model, serial number, etc.
17
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Table of Contents
Chapter 1
1.1 1.2 1.3 1.4
1.4.1 1.4.2
Overview .................................................................................22
1.5 1.6
Chapter 2
2.1 2.2
2.2.1 2.2.2
Installation ..............................................................................33
2.3
2.3.1 2.3.2
Chapter 3 Chapter 4
4.1 4.2 4.3 4.4
4.4.1 4.4.2
Setting the ETERNUS DX S2 .......................................................................... 45 Turning on the Power Synchronized Unit ......................................................... 47 Connecting Cascade Cables ............................................................................ 50 Connecting to the Server UPS Unit .................................................................. 52
Connecting the Server UPS Unit to the Power Synchronized Unit ............................................ 53 Connecting the AC Sensor Unit ................................................................................................. 54
4.5 4.6
Chapter 5
5.1 5.2
Connection Procedure when Adding a Server ................................................. 60 Connection Procedure when Adding an ETERNUS DX S2 ............................. 62
Chapter 6
6.1
18
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Table of Contents
6.2
6.2.1 6.2.2 6.2.3
6.3
6.3.1 6.3.2
Troubleshooting ............................................................................................... 70
Check List .................................................................................................................................. 70 Trouble Record .......................................................................................................................... 73
Index
.........................................................................................................74
19
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
List of Figures
Figure 1.1 Figure 1.2 Figure 1.3 Figure 1.4 Figure 1.5 Figure 1.6
External view of a power synchronized unit .............................................................................. External view of an AC sensor unit ........................................................................................... Components (power synchronized unit) .................................................................................... Components (AC sensor unit) ................................................................................................... System configuration example (power synchronization with two server UPS units) ................. System configuration example (power synchronization with three or more server UPS units).......................................................................................................................................... Figure 1.7 Power on using a power synchronized unit ............................................................................... Figure 1.8 Operation timing chart when using a power synchronized unit (powering on) .......................... Figure 1.9 Power off using a power synchronized unit ............................................................................... Figure 1.10 Operation timing chart when using a power synchronized unit (powering off) .......................... Figure 4.1 ETERNUS DX80 S2/DX90 S2 setup (Setup Power Management screen) ............................... Figure 4.2 ETERNUS DX60 S2 setup (Setup Power Management screen) .............................................. Figure 4.3 Cascade cable connection ....................................................................................................... Figure 4.4 Connection for the server UPS units and the AC sensor units.................................................. Figure 6.1 Trouble record ...........................................................................................................................
22 22 25 26 27 28 29 30 31 32 45 46 50 52 73
20
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
List of Tables
Table 1.1 Table 2.1 Table 2.2 Table 2.3 Table 6.1
Specifications ............................................................................................................................ List of package contents (power synchronized unit).................................................................. List of package contents (AC sensor unit)................................................................................. Power socket type and AC cable (for AC power input) length................................................... Status and meanings of each LED ............................................................................................
24 33 33 34 66
21
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 1
Overview
This chapter provides external views, features, specifications, and system configuration examples of the power synchronized unit and the AC sensor unit (optional). The names and usages of the various components of the power synchronized unit and the AC sensor unit are also described.
1.1
External View
Figure 1.1 and Figure 1.2 show the external views of the power synchronized unit and the AC sensor unit.
Figure 1.1
AC sensor unit
Figure 1.2
22
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
1.2
Features
This section explains the features of the power synchronized unit and the AC sensor unit. Powering the ETERNUS DX S2 on and off can be synchronized with a server by connecting to the Uninterruptible Power Supply (UPS) unit to which the server is connected. As well as the UPS unit to which the server is connected (referred to as "server UPS unit" in the remainder of this manual), the power synchronized unit can be connected to a unit that can control the output of an AC outlet. The sizes of the power synchronized unit and the AC sensor unit are 1U. These units can be installed in a 19-inch rack for the server or the ETERNUS DX S2. Two server UPS units can be connected to manage power synchronization in a standard configuration. By adding an AC sensor unit, up to 16 server UPS units can be connected. By serially connecting each AC sensor unit, the distance between a server UPS unit and a power synchronized unit can be extended by up to 100m. By cascading power synchronized units, the power of up to eight ETERNUS DX S2s can be controlled. A redundant configuration is available by using two power synchronized units. Power synchronization starts when the power synchronized unit is connected to the server UPS unit and the ETERNUS DX S2 by cables. Connection procedures can be performed while the server UPS unit and the ETERNUS DX S2 are operating. The status of the power synchronized unit and the status of the AC power output from the server UPS unit are displayed on the LED. If an error occurs, tracking the error and error recovery can be performed based on the LED information.
23
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
1.3
Specifications
Table 1.1 shows the specifications of the power synchronized unit and the AC sensor unit. Table 1.1 Specifications
Item Dimensions (W D H) Weight Power synchronized unit AC sensor unit Power synchronized unit AC sensor unit Voltage Power Maximum power requirements Maximum heat generation Connection interface Server UPS unit ETERNUS DX S2 Phase Frequency AC100 - 120V AC200 - 240V AC100 - 120V AC200 - 240V For ETERNUS DX S2s For AC detection Basic Maximum (when AC sensor units are connected) Basic Maximum (when a cascade connection is used) Between a power synchronized unit and an AC sensor unit (total) Cable length Between a power synchronized unit and the ETERNUS DX S2 Between power synchronized units Conditions to detect AC output Power consumption Voltage Phase Support for a duplicated configuration Temperature Environmental condition Humidity Specifications 440 230 40 (mm) [1U] 100 150 40 (mm) [1U] 4.0kg 1.3kg AC100 - 120V, AC200 - 240V Single 50Hz/60Hz 3W 7W 11kJ/h 26kJ/h RS232C 4 AC sensor 2 2 16 4 8 Max. 100m Max. 5m Max. 10m 0.1A or less AC output for one second or more is detected. AC100V / AC200V Single Yes 5 - 40C (during operation) 0 - 50C (during non-operation) 20 - 80%RH (during operation) 8 - 80%RH (during non-operation)
24
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
1.4
Components
This section describes the names and usage of the various components for the power synchronized unit and the AC sensor unit.
1.4.1
CHECK LED
Displays the starting status of a power synchronized unit
CASCADE port
For cascading two power synchronized units with a cascade cable to the CASCADE port on the first power synchronized unit
RCI port
Not used
AC IN port
For AC cable (for AC power input) connection
Figure 1.3
25
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
1.4.2
LED
Lights up green when AC output from a server UPS unit is detected
Figure 1.4
26
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
1.5
System Configuration
System configuration examples when the power synchronized unit is used are shown below. The server UPS unit must have a function in the management software (PowerChute plus, etc.) that controls the AC power output according to when the server powers on and off.
Server#1
(*1)
UPS unit for Server#1
(*1)
SENSOR#0
SENSOR#1
PWC#0
(*1)
PWC
ETERNUS DX S2
*1: For AC100V connections, AC cables for AC100V must be purchased separately.
AC cable (for AC sensor) AC cable (for AC power input) RS232C cable The cables listed above are provided with a power synchronized unit.
Figure 1.5
System configuration example (power synchronization with two server UPS units)
27
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
(*3)
(*1)
Server#0
UPS unit for Server#0
Server#2
UPS unit for Server#2
~ ~
(*3)
SENSOR#0
SENSOR#1
AC SENSOR
CASCADE
PWC
(*3) ETERNUS DX S2 #0
PWC
PWC
PWC
PWC
PWC *1: Do not attach a termination resistor to the branch connector on the AC sensor unit. *2: For a cascade connection, do not connect the server UPS unit to power synchronized unit#1. *3: For AC100V connections, AC cables for AC100V must be purchased separately. AC cable (for AC sensor) AC cable (for AC power input) RS232C cable Cascade cable AC sensor port connection cable Provided cables are indicated by solid lines. Optional cables are indicated by dotted lines.
(*3) ETERNUS DX S2 #4
PWC
PWC
ETERNUS DX S2 #5
PWC
Figure 1.6
System configuration example (power synchronization with three or more server UPS units)
28
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
1.6
UPS setting
UPS setting
3, 6
Server#0
3, 6
Server#1
UPS management software
1
Power synchronized unit
Figure 1.7
29
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
1 2 3
Power on of an ETERNUS DX S2 UPS unit Issuance of command to turn on the server (power on of the server UPS units) Server startup (OS startup is suspended)
The server OS startup is suspended until the ETERNUS DX S2 startup is complete. For the set suspend time of the server, refer to "Figure 1.8 Operation timing chart when using a power synchronized unit (powering on)" (page 30).
4 5 6
Issuance of command to turn on the ETERNUS DX S2 from the power synchronized unit ETERNUS DX S2 startup Server OS startup
The following figure shows the timing chart of power on operations for scheduled operations and power recovery. For details about setting items and values, refer to the manual of the expansion card that is installed in the UPS unit and the manual of the UPS management software that is used.
2 Issuance of command to turn on the server
S1(>E1) Server Shutdown state
3 OS startup suspension
6 OS startup
Operating
OFF
ON
4 Issuance of command to turn on the ETERNUS DX S2 from the power synchronized unit
E1 ETERNUS DX S2 5 Startup Operating
OFF
ON
S1: Waiting time interval starting from when the command is issued to turn on the server to the beginning of the OS startup process. Set a longer time than the time that is required to complete ETERNUS DX S2 startup (E1). E1: Time that is required to complete ETERNUS DX S2 startup from the start of powering on of the ETERNUS DX S2 ETERNUS DX60 S2 : Three minutes and more ETERNUS DX80 S2/DX90 S2: Two minutes and more
Figure 1.8
Operation timing chart when using a power synchronized unit (powering on)
30
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
1
Server#0
1
Server#1
UPS management software
5
An instruction is issued to turn off the ETERNUS DX S2 when no AC output is detected. Power synchronized unit PWC ETERNUS DX S2 RS232C cable PWC ETERNUS DX S2 UPS unit
Figure 1.9
1 2 3 4 5
Shutdown of all the servers Shutdown of all the server UPS units Issuance of command to turn off the ETERNUS DX S2 from the power synchronized unit ETERNUS DX S2 shutdown Shutdown of the ETERNUS DX S2 UPS unit
31
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
The following figure shows the timing chart of power off operations for scheduled operations or for when a power failure occurs. For details about setting items and values, refer to the manual of the expansion card that is installed in the UPS unit and the manual of the UPS management software that is used.
(0 Power failure occurred (commercial power is stopped)) 1 Shutdown of the server (Server shutdown starts)
S2 Server Operating Shutdown process Shutdown state
3 Issuance of command to shut down the ETERNUS DX S2 from the power synchronized unit 5 UPS shutdown (Power supply stops)
E2 (Six minutes and more)
ETERNUS DX S2
4 Shutdown process
OFF
S2: Processing time for server shutdown S3: Battery operation time until server UPS unit shutdown when a power failure occurs. E2: Required time to turn off the ETERNUS DX S2 (six minutes and more) E3: Battery operation time until ETERNUS DX S2 UPS unit shutdown when a power failure occurs.
Figure 1.10 Operation timing chart when using a power synchronized unit (powering off)
32
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 2
Installation
This chapter describes the installation procedures for the power synchronized unit and the AC sensor unit. Make sure to check "Safety Precautions" (page 10) before installation.
2.1
Package contents Power synchronized unit AC cable RS232C cable Rack mount kit User's Guide
Table 2.2
Package contents AC sensor unit AC cable AC sensor port connection cable Branch connector Rubber foot Rack mount kit
33
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
2.2
2.2.1
Preparation
Installation Area
Placement area
Refer to the placement area of the rack to install the power synchronized unit and the AC sensor unit.
Installation condition
Install the power synchronized unit and the AC sensor unit in an area that meets all the conditions described in "Instructions for installation" (page 11) of "Safety Precautions".
2.2.2
IMPORTANT
When determining the rack-mounting layout, consider the length of each AC cable. For example, a power synchronized unit that is installed at the top of a 1,800mm rack requires about 2m of AC cable (4m) to reach the bottom of the rack.
Table 2.3
34
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
2.3
Installing in a Rack
This section explains how to install a power synchronized unit and an AC sensor unit in a rack. Make sure to check "Safety Precautions" (page 10) before installing the power synchronized unit and the AC sensor unit in a rack. Also refer to the manual that is provided with the racks.
Do
CAUTION
If the power synchronized unit and the AC sensor unit are installed or disassembled other than as described in this manual, device failure or electrical shock may occur. The power synchronized unit contains delicate components, and should be handled gently. Do not drop or knock the power synchronized unit against the rack during installation. For an empty space in a rack without installed components, install the blank panel that is provided with the rack.
Do Not
When installing the power synchronized unit with other devices in the same rack, the airflow of the device installed on and under the power synchronized unit may interfere with each other and affect the cooling of the device. Make sure to leave plenty of room between the devices if required. Not doing so may damage the power synchronized unit and cause the power synchronized unit to malfunction. Do not obstruct the air vents in the power synchronized unit.
Temperature
For enclosed racks with doors, or when multiple devices are installed and running, the temperature inside the rack is considerably higher than the temperature of the room. Make sure the temperature inside the rack is lower than 40C. Not doing so may damage the power synchronized unit.
35
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
2.3.1
Blank panel: 1
Procedure
1 2
Open the front and rear doors of the rack. Attach the M6 cage nuts to the rear rack pillar.
Attachment positions Insert four M6 cage nuts in the 1st and 3rd holes above the power synchronized unit base line.
(Rear rack pillars)
36
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Attachment procedure
Clip the M6 cage nut tabs into the desired hole from the inside.
L-shaped bracket
L-shaped bracket
37
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
M6 cross recessed head screws with captive washer (Rear rack pillars)
Blank panel
End of procedure
38
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
2.3.2
IMPORTANT
The length of the AC cable (for AC sensor) that connects the AC sensor unit and the server UPS unit is 4m. Install the AC sensor unit in the same rack as the server UPS unit.
M6 cage nut: 4
Blank panel: 1
39
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Procedure
1 2
Open the front and rear doors of the rack. Attach the M6 cage nuts to the rear rack pillar.
Attachment positions Insert four M6 cage nuts in the 1st and 3rd holes above the AC sensor unit base line.
(Rear rack pillars)
Attachment procedure
Clip the M6 cage nut tabs into the desired hole from the inside.
L-shaped bracket
40
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Up to two AC sensor units can be attached to the same shelf plate. Attach the first AC sensor unit on the right side when facing the shelf plate as shown in the figure above.
M6 cross recessed head screws with captive washer (Rear rack pillars)
41
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Blank panel
End of procedure
42
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 3
This chapter explains how to turn on and off the power synchronized unit.
Powering on
When an AC cable (for AC power input) is connected to the AC IN port and the power socket, the power synchronized unit turns on. For details about how to connect an AC cable (for AC power input), refer to "4.2 Turning on the Power Synchronized Unit" (page 47).
Powering off
When an AC cable (for AC power input) is disconnected from the AC IN port, the power synchronized unit turns off. For normal operation, there is no need to turn the power off. If the power synchronized unit must be turned off, such as before any inspections of power supply devices are performed, check that the power synchronized unit and the devices that connect the power synchronized unit are all turned off before disconnecting the AC cables (for AC power input).
43
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 4
This chapter describes the installation and setting procedures for a power synchronized unit and an AC sensor unit. If your sales representative or maintenance engineer does not perform the settings of the power synchronized unit and the AC sensor unit, perform the settings yourself. Attach labels to each cable that is to be connected and make a note of the connection source and destination. This helps with cable management and prevents incorrect connections. For the connection and setting details of a device that is connected to the power synchronized unit, refer to the manual that is provided with the connected device.
Workflow
Perform the following procedure for connection and settings:
Procedure
1 2 3 4 5 6
When five or more ETERNUS DX S2s are installed, connect the cascade cables.
For details, refer to "4.3 Connecting Cascade Cables" (page 50).
When three or more server UPS units are connected, connect the AC sensor unit.
For details, refer to "4.4.2 Connecting the AC Sensor Unit" (page 54).
End of procedure
44
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
4.1
Figure 4.1
Enable Select the controllers (CM#0 and/or CM#1) of the ETERNUS DX80 S2/DX90 S2 Disk storage system that are connected to the power synchronized unit with the RS232C cable. Select "CM#0" when the power synchronized unit is connected to the PWC port on controller 0. Select "CM#1" when the power synchronized unit is connected to the PWC port on controller 1. When different power synchronized units are connected to controller 0 and controller 1 in a duplicated configuration, select both "CM#0" and "CM#1". Delay until Shutdown (min.) Do not change the default setting (0 minute). Set management unit interface Select "Power Synchronized Unit".
45
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Power Failure Signal "Positive" (positive logic) is automatically set. Low Battery Signal "Negative" (negative logic) is automatically set. UPS Shutdown Signal Do not select the "Enable" checkbox. "Positive" (positive logic) is set by default. Auto Power Select "Disable". Power Resume Select "Disable".
ETERNUS DX60 S2
This section explains the setting items on the power synchronization setting screen for the ETERNUS DX60 S2 Disk storage system.
Figure 4.2
Enable Select the controllers (CM#0 and/or CM#1) of the ETERNUS DX60 S2 Disk storage system that are connected to the power synchronized unit with the RS232C cable. Select "CM#0" when the power synchronized unit is connected to the PWC port on controller 0. Select "CM#1" when the power synchronized unit is connected to the PWC port on controller 1. When different power synchronized units are connected to controller 0 and controller 1 in a duplicated configuration, select both "CM#0" and "CM#1". Delay until Shutdown (min.) Do not change the default setting (0 minute). Set management unit interface Select "Power Synchronized Unit".
46
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 4 Connection and Settings 4.2 Turning on the Power Synchronized Unit
Power Failure Signal "Positive" (positive logic) is automatically set. Low Battery Signal "Negative" (negative logic) is automatically set. UPS Shutdown Signal Do not select the "Enable" checkbox. "Positive" (positive logic) is set by default.
4.2
WARNING
Do not disconnect the power cord plug with wet hands. Doing so may cause electrical shock. Do not damage or modify the AC cable or the power plug. Heating, forced bending, twisting, pulling, or placing heavy objects on the AC cable or the power plug will damage it, causing fire or electrical shock. Do not place any stress on the root of the AC cable, such as by twisting it. Doing so may expose or cut the cable core of the AC cable, causing fire or electric shock. Do not use the AC cable or the power cord if it is damaged or the plug does not snugly fit into the socket. Doing so may cause electric shock or fire. Do not use an AC cable other than the one attached or specified. Do not use an attached AC cable or specified AC cable for other devices. Doing so may cause failure, fire, or electric shock.
Unplug
Use a dry cloth to remove all dust from plugs and power sockets. Not doing so may cause electrical shock or fire.
47
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 4 Connection and Settings 4.2 Turning on the Power Synchronized Unit
Ground
CAUTION
Use only power sockets that have a ground. Using ungrounded power sockets may cause fire, electric shock, or malfunction.
Procedure
Connect the AC cable (for AC power input) to the power synchronized unit.
1-1 Connect the power plug of the AC cable (for AC power input) to the AC IN port.
AC cable (for AC power input)
AC IN port
1-2 Attach the release tie to the plug of the AC cable (for AC power input) to firmly fix the
power plug to ensure it does not become unplugged.
Release tie
Connect the power plug at the other end of the AC cable to the power socket.
When the power plug is connected to the power socket, the power synchronized unit is turned on. Check that the CHECK LED is off and the POWER LED is blinking green on the power synchronized unit.
IMPORTANT
Connect the power plug to the power socket that belongs to the same power line as the ETERNUS DX S2. Do not connect the power plug to a server UPS unit.
48
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 4 Connection and Settings 4.2 Turning on the Power Synchronized Unit
Do
CAUTION
Make sure the plug is fully inserted into the power socket. Not doing so may cause fire or electrical shock.
Do Not
When unplugging the power cord, hold the plug. Do not pull on the cord. Pulling the cord may expose or snap the inner wires, which may cause fire or electrical shock. Do not use the server service outlet to connect the AC cable for the power synchronized unit. Do not overload electrical sockets. Doing so may cause electric shock or fire.
Unplug
When the power synchronized unit is not used for a long period of time, unplug all power plugs. Not doing so may cause fire.
End of procedure
49
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
4.3
Server#1
UPS unit for Server#1
CASCADE port
Figure 4.3
Cascade cable connection When the power synchronized units are cascaded, the unit that is connected to the server UPS unit is "power synchronized unit#0". Do not attach a branch connector or a termination resistor to the CASCADE port or the AC SENSOR port. Doing so makes operations unstable.
IMPORTANT
Do
CAUTION
When connecting external (signal, power, etc.) cables, avoid placing stress on them. Not doing so may damage the cables.
Do Not
Do not bend the cable too much or bind it up. Doing so may damage the cable and cause the power synchronized unit to malfunction.
90
Do not bind up
50
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Procedure
Cascade cable
2 3
Cascade cable
End of procedure
51
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 4 Connection and Settings 4.4 Connecting to the Server UPS Unit
4.4
Server#0
UPS unit for Server#0
SENSOR#0 port
SENSOR#1 port
....
AC sensor unit
AC In port Branch connector
Server#2
UPS unit for Server#2
Server#3
UPS unit for Server#3
Figure 4.4
Connection for the server UPS units and the AC sensor units The AC cable (for AC sensor) that is connected to a server UPS unit is a cable for detecting the AC output status of a server UPS unit. This cable does not supply AC power to the power synchronized unit.
IMPORTANT
For details about settings for a server UPS unit that is connected to the power synchronized unit, refer to the manual that is provided with the server UPS unit and perform the appropriate settings.
52
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 4 Connection and Settings 4.4 Connecting to the Server UPS Unit
Do
CAUTION
When connecting external (signal, power, etc.) cables, avoid placing stress on them. Not doing so may damage the cables.
Do Not
Do not bend the cable too much or bind it up. Doing so may damage the cable and cause the power synchronized unit to malfunction.
90
Do not bind up
4.4.1
Procedure
1-1 Connect the plugs of the AC cables (for AC sensor) to SENSOR#0 port and
53
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 4 Connection and Settings 4.4 Connecting to the Server UPS Unit
1-2 Attach the release ties to the plugs of the AC cables (for AC sensor) to firmly fix the
power plugs to ensure they do not become unplugged.
Release ties
Connect the plugs at the other ends to the server UPS units.
Connect the plugs of the AC cables (for AC sensor) at the other ends to the output outlets of the server UPS units.
End of procedure
4.4.2
Procedure
Connect the AC sensor unit and the server UPS unit with the AC cable (for AC sensor).
unit.
AC cable (for AC sensor)
1-1 Connect the plug of the AC cable (for AC sensor) to the AC In port on the AC sensor
AC In port
1-2 Connect the plug at the other end of the AC cable (for AC sensor) to the outlet of the
server UPS unit.
54
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 4 Connection and Settings 4.4 Connecting to the Server UPS Unit
Connect the AC sensor unit to the power synchronized unit with the AC sensor port connection cable.
When connecting the AC sensor port connection cable, check the connector orientation and then firmly push it all the way in. When disconnecting the AC sensor port connection cable, hold the tab of the connector while pulling it out.
2-1 Attach the branch connector to the AC sensor output port of the AC sensor unit.
A branch connector is provided with the AC sensor unit.
Branch connector
2-2 Connect the AC sensor port connection cable to one of the ports on the branch
connector that was attached in Step 2-1.
Branch connector
2-3 Connect the connector at the other end of the AC sensor port connection cable to the
AC SENSOR port on the power synchronized unit.
AC SENSOR port Power synchronized unit
55
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 4 Connection and Settings 4.4 Connecting to the Server UPS Unit
When two or more AC sensor units are connected, connect the AC sensor units with the AC sensor port connection cables.
connector.
3-1 Connect the AC sensor port connection cable to the other port on the branch
3-2 Connect the connector at the other end of the AC sensor port connection cable to
another AC sensor unit.
Branch connector
IMPORTANT
Up to 14 AC sensor units can be connected. Do not attach a termination resistor to the branch connector on the AC sensor unit. Doing so makes operations unstable.
End of procedure
56
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
4.5
IMPORTANT
Up to four ETERNUS DX S2s can be connected to each power synchronized unit. When power synchronized units are cascaded, up to eight ETERNUS DX S2s can be connected.
Do
CAUTION
When connecting external (signal, power, etc.) cables, avoid placing stress on them. Not doing so may damage the cables.
Do Not
Do not bend the cable too much or bind it up. Doing so may damage the cable and cause the power synchronized unit to malfunction.
90
Do not bind up
57
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Procedure
RS232C cable
PWC ports
58
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
ETERNUS DX60 S2
End of procedure
4.6
59
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 5
Devices (servers, power synchronized units, and ETERNUS DX S2s) that are to be power synchronized can be added during system operation. This chapter explains how to connect a power synchronized unit when these devices are added. Make sure to check "Safety Precautions" (page 10) or the manual provided with the server or the ETERNUS DX S2 before adding a device.
5.1
Procedure
Connect the server UPS unit for the added server to the power synchronized unit.
An example of a connection between server UPS units and a power synchronized unit is shown below. For details about how to connect a server UPS unit to the power synchronized unit, refer to "4.4.1 Connecting the Server UPS Unit to the Power Synchronized Unit" (page 53).
Server#1
UPS unit for Server#1
Added server
Server#0
UPS unit for Server#0
SENSOR#1 port
60
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 5 Adding a Connecting Device 5.1 Connection Procedure when Adding a Server
When two or more servers are added, use the AC sensor units to connect the server UPS units for the added servers to the power synchronized unit.
An example of connecting AC sensor units, server UPS units, and a power synchronized unit is shown below.
1 Connect the server UPS units and the AC sensor units. 2 Connect the AC sensor units and the power synchronized unit. 3 When two or more AC sensor units are used, connect the AC sensor units.
For details about the connection procedure when using an AC sensor unit, refer to "4.4.2 Connecting the AC Sensor Unit" (page 54).
Server#1
UPS unit for Server#1
Server#0
UPS unit for Server#0
AC SENSOR port
AC sensor unit
Branch connector
AC In port
End of procedure
After the procedure is complete, check that power synchronization performs normally if necessary.
61
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 5 Adding a Connecting Device 5.2 Connection Procedure when Adding an ETERNUS DX S2
5.2
Procedure
Set the required settings for power synchronization of the ETERNUS DX S2s that are to be added.
For details about the ETERNUS DX S2 settings, refer to "4.1 Setting the ETERNUS DX S2" (page 45).
62
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 5 Adding a Connecting Device 5.2 Connection Procedure when Adding an ETERNUS DX S2
Server#0
UPS unit for Server#0
Server#1
UPS unit for Server#1
ETERNUS DX S2#0
PWC
Added ETERNUS DX S2
ETERNUS DX S2#2
PWC
Added ETERNUS DX S2
ETERNUS DX S2#3
PWC
Added ETERNUS DX S2
End of procedure
Power synchronization starts when the connection is complete. Check that power synchronization performs normally.
Procedure
Set the required settings for power synchronization of the ETERNUS DX S2s that are to be added.
For details about the ETERNUS DX S2 settings, refer to "4.1 Setting the ETERNUS DX S2" (page 45).
2 3
63
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 5 Adding a Connecting Device 5.2 Connection Procedure when Adding an ETERNUS DX S2
Server#1
UPS unit for Server#1
CASCADE port
ETERNUS DX S2#0
PWC
AC SENSOR port
ETERNUS DX S2#1
PWC
ETERNUS DX S2#2
PWC
ETERNUS DX S2#3
PWC
64
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 5 Adding a Connecting Device 5.2 Connection Procedure when Adding an ETERNUS DX S2
Connect the ETERNUS DX S2s to the power synchronized units. An example of a connection between five or more ETERNUS DX S2s and power synchronized units is shown below. For details about how to connect an ETERNUS DX S2 to the power synchronized unit, refer to "4.5 Connecting to the ETERNUS DX S2" (page 57).
Server#0
UPS unit for Server#0
Server#1
UPS unit for Server#1
ETERNUS DX S2#0
ETERNUS DX S2#1
ETERNUS DX S2#2
ETERNUS DX S2#4
PWC
ETERNUS DX S2#3
ETERNUS DX S2#5
PWC
ETERNUS DX S2#6
PWC
ETERNUS DX S2#7
PWC
End of procedure
Power synchronization starts when connection is complete. Check that power synchronization performs normally.
65
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 6
This chapter describes maintenance and troubleshooting after starting system operation.
6.1
(on) POWER (green) Displays the power status of the power synchronized unit.
(blinks)
Displays that the power synchronized unit has commanded the ETERNUS DX S2 to turn on or off.
(off)
(on)
66
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 6 Operation and Maintenance 6.1 Checking the Power Synchronized Unit Status
LED name
Function
Power synchronized unit status All of the ETERNUS DX S2s are off. The ETERNUS DX S2s is on. The ETERNUS DX S2 is still on even after the power synchronized unit commands the ETERNUS DX S2 to turn off (such as when shutting down the ETERNUS DX S2). The power synchronized unit is operating normally. The power synchronized unit is starting up.
(on)
CHECK (Yellow)
67
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 6 Operation and Maintenance 6.2 Device Replacement After Operation Startup
6.2
CAUTION
Ask your maintenance engineer to replace devices.
6.2.1
Replacing a Server
The following procedure provides an overview of the required work to replace a server, such as when a server fails. Refer to the relevant manuals for more details.
Procedure
1 2 3
Replace the server. Perform the necessary settings for the replacement server. Connect the replacement server to the server UPS unit.
End of procedure
After the procedure is complete, check that power synchronization performs normally if necessary.
68
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Chapter 6 Operation and Maintenance 6.2 Device Replacement After Operation Startup
6.2.2
IMPORTANT
Make sure to use the following procedure to replace a power synchronized unit.
Procedure
1 2 3 4 5
Remove the AC cables (for AC sensor), the AC sensor port connection cables, and the cascade cables from the power synchronized unit. Remove the AC cable (for AC power input) from the power synchronized unit and turn off the power synchronized unit. Remove the power synchronized unit from the rack. Install the new power synchronized unit and connect the required cables.
To connect the cables, perform the procedure for disconnecting cables in reverse. Connect the RS232C cables last.
End of procedure
After completing cable connection, check that power synchronization performs normally if necessary.
6.2.3
IMPORTANT
Procedure
1 2
Remove the AC sensor port connection cable from the AC sensor unit.
69
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
3 4 5
Remove the AC cable (for AC sensor) from the AC sensor unit. Remove the AC sensor unit from the rack. Install the new AC sensor unit and connect the required cables.
To connect the cables, perform the procedure for disconnecting cables in reverse. Connect the RS232C cables last.
End of procedure
After completing cable connection, check that power synchronization performs normally if necessary.
6.3
Troubleshooting
If you notice anything unusual during operation such as the conditions listed below, refer to "6.3.1 Check List" (page 70) to check the power synchronized unit status, accurately record the status on the form provided in "6.3.2 Trouble Record" (page 73), and contact your maintenance engineer. Unusual phenomena occurs during operation of the power synchronized unit The power synchronized unit does not turn on The ETERNUS DX S2 does not turn off with the power synchronized server The ETERNUS DX S2 does not turn on with the power synchronized server
6.3.1
Check List
Unusual phenomena occurs during operation of the power synchronized unit
If any of the following conditions apply to the power synchronized unit, remove the AC cables of the power synchronized unit and contact your maintenance engineer.
IMPORTANT
Remove the AC cable (for AC power input) that is connected to the AC IN port first, then remove the AC cables (for AC sensor) that are connected to the ports of SENSOR#0 and SENSOR#1.
Abnormally hot Unusual odor Emission of smoke Unusual noise Abnormal shaking
70
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Unplug
WARNING
If the power synchronized unit overheats, gives off smoke or an unusual odor, makes an unusual sound, or shakes abnormally, or is likely to be damaged by a power abnormality, immediately remove the AC cables. After waiting a while, check that the unusual phenomena has disappeared, and then contact your sales representative or maintenance engineer.
The ETERNUS DX S2 does not turn off with the power synchronized server
Check the following points: If you still have trouble, leave the power synchronized unit as it is and contact your sales representative or maintenance engineer. The power synchronized unit is not turned on. The POWER LED and POWER SENSOR LED are on. - Check the status for the SENSOR#0 port and SENSOR#1 port on the power synchronized unit and the status for the AC output of the server UPS unit to which the AC sensor unit is connected. The AC output of all the connected sever UPS units needs to be off to turn off the ETERNUS DX S2. - Check the status for the SENSOR#0 port and SENSOR#1 port on the power synchronized unit and the status of the cable connection for the AC sensor unit. - When the power synchronized units are cascaded, check the connection status of the cascade cables. The POWER LED is on and the POWER CONTROL LED is blinking. - Check that the ETERNUS DX S2 is not being turned off. It may take up to five minutes for the ETERNUS DX S2 to turn off. Wait for a while and check that the status of the LEDs does not change. - When different power synchronized units are connected to both controllers (CM#0 and CM#1) on the ETERNUS DX S2, the ETERNUS DX S2 must be turned off by both power synchronized units. - Check that power synchronization with the power synchronized unit is correctly set for the ETERNUS DX S2.
71
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
The ETERNUS DX S2 does not turn on with the power synchronized server
The power synchronized unit is not turned on. The POWER LED and POWER SENSOR LED are on. - Check that power synchronization with the power synchronized unit is correctly set for the ETERNUS DX S2. - Check the connection status of the RS232C cable that connects the power synchronized unit and the ETERNUS DX S2. When the POWER LED is on. - Check the status for the SENSOR#0 port and SENSOR#1 port on the power synchronized unit and the status for the AC output of the server UPS unit to which the AC sensor unit is connected. The AC output of at least one of the connected sever UPS units need to be on to turn on the ETERNUS DX S2. - Check the status for the SENSOR#0 port and SENSOR#1 port on the power synchronized unit and the status of the cable connection for the AC sensor unit. - When the power synchronized units are cascaded, check the connection status of the cascade cables.
72
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
6.3.2
Trouble Record
If trouble occurs, record the power synchronized unit and AC sensor unit conditions in Figure 6.1, and contact your maintenance engineer.
Trouble Record
1: Please identify your power synchronized unit: (Check the Manufacturers label) MODEL SER.NO. 2: Please enter the following information: No. of connected server UPS units Model names of connected server UPS units No. of connected AC sensor units No. of connected storage systems Is the power synchronized unit cascaded? (Yes, No)
3: Check the state of the following LEDs on the power synchronized unit: POWER POWER SENSOR POWER CONTROL CHECK (On, Off, Blinking) (On, Off) (On, Off, Blinking) (On, Off, Blinking)
Figure 6.1
Trouble record
73
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Index
A
AC cable (for AC power input)............................ 48 AC cable (for AC sensor) .............................. 53, 54 AC IN port...................................................... 25, 48 AC In port ...................................................... 26, 54 AC sensor output port ................................... 26, 55 AC SENSOR port .................................... 25, 51, 55 AC sensor port connection cable ....................... 55 AC sensor unit Components ................................................. 26 Connection.................................................... 54 Device replacement ...................................... 69 External view ................................................ 22 Installing in a rack ......................................... 40 Package contents ......................................... 33 Rack mount kit .............................................. 39 Adding a device.................................................. 60 Procedure when adding a server.................. 60 Procedure when adding an ETERNUS DX S2................................. 62
E
ETERNUS DX S2 setup ..................................... 45 External view ...................................................... 22 AC sensor unit .............................................. 22
F
Features ............................................................. 23
I
Installation area .................................................. Installing in a rack ............................................... AC sensor unit .............................................. Power synchronized unit............................... 34 35 40 36
L
LED Status display................................................ 66 LED (AC sensor unit).......................................... 26
B
Branch connector ............................................... 55
C
Cascade cable.................................................... 51 Cascade connection........................................... 50 CASCADE port .............................................. 25, 51 CHECK LED ....................................................... 25 Checking after connection.................................. 59 Components ....................................................... 25 AC sensor unit .............................................. 26 Power synchronized unit............................... 25 Connecting to the ETERNUS DX S2.................. 57 Connecting to the server UPS unit ..................... 53 Connection ......................................................... 44
M
Maintenance after starting system operation...... 66
P
Package contents ............................................... AC sensor unit .............................................. Power synchronized unit............................... POWER CONTROL LED ................................... POWER LED ...................................................... POWER SENSOR LED...................................... Power socket Quantity......................................................... Type .............................................................. Power synchronized unit Components.................................................. Device replacement ...................................... External view................................................. Installing in a rack ......................................... Package contents ......................................... Rack mount kit .............................................. 33 33 33 25 25 25 34 34 25 69 22 36 33 36
D
Device replacement............................................ AC sensor unit .............................................. Power synchronized unit............................... Server ........................................................... 68 69 69 68
74
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
Index
Powering off sequence....................................... 31 Powering on ....................................................... 48 Powering on sequence....................................... 29 PWC port....................................................... 25, 58
R
Rack mount kit AC sensor unit .............................................. 39 Power synchronized unit............................... 36 RS232C cable .................................................... 58
S
SENSOR port ................................................ 25, 53 Server Device replacement ...................................... 68 Settings .............................................................. 44 Specifications ..................................................... 24 System configuration example ........................... 27 Power synchronization with three or more server UPS units ....................................... 28 Power synchronization with two server UPS units........................................................... 27
T
Trouble record .................................................... 73 Troubleshooting.................................................. 70
75
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system Users Guide -Power Synchronized UnitCopyright 2012 FUJITSU LIMITED P3AM-2532-06EN
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system User's Guide -Power Synchronized UnitP3AM-2532-06EN
Date of issuance: March 2012 Issuance responsibility: FUJITSU LIMITED Printed in Japan
The contents of this manual may be updated without notice. While the contents of this manual are the product of all due care and diligence, no responsibility can be accepted for operational problems arising from any errors or missing information, or other use of the information contained in this manual. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. Contents of this manual are not to be reproduced without permission from Fujitsu. Manuals with missing or wrongly collated pages will be replaced free of charge.