Professional Documents
Culture Documents
Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: Email:
Issue 01 (2011-04-30)
Contents
Contents
1 About This Document..................................................................................................................1
1.1 Scope..............................................................................................................................................................................1 1.2 Intended Audience..........................................................................................................................................................1 1.3 Change History...............................................................................................................................................................1
Issue 01 (2011-04-30)
ii
1
1.1 Scope 1.2 Intended Audience
This document describes WRFD-010211 Active TX Chain Gain Calibration, including its technical principles.
This document is intended for personnel who: l l Need to understand the features described herein Work with Huawei products
01 (2011-04-30)
This issue does not include any changes.
Draft B (2011-03-30)
This issue does not include any changes.
Issue 01 (2011-04-30)
Draft A (2010-12-30)
Compared with Issue 01 (2010-03-30) of RAN12.0, Draft A (2010-12-30) of RAN13.0 optimizes the description.
Issue 01 (2011-04-30)
2 Overview
Overview
This feature provides high output power accuracy for the NodeB and reduces the margins required in network dimensioning. Thus, the power can be fully utilized.
Issue 01 (2011-04-30)
3 Technical Description
Technical Description
The active TX chain gain calibration can increase the accuracy of the downlink transmit power (for example, the power accuracy of the 3900 series NodeB is 0.6 dB), thus reducing the protection band reserved for power calculation in network planning and improving the utilization of transmit power. Performance drift occurs on all RF hardware. The gain of an RF part (for example, TRX, PA, RF connector, or duplexer) is related to the temperature, frequency, and lot number. Such a gain difference leads to a 1.5 dB to 2 dB error in the NodeB transmit power. The active TX chain gain calibration can reduce the changes in analog channel gains caused by different temperatures, frequencies, and lot numbers, thus ensuring a stable total gain of links. The active TX chain gain calibration method calculates the difference between the downlink input power and transmit power and then adjusts digital channel gains based on the transmit power on the analog channel. Gain control is performed in real time, thus ensuring the accuracy of transmit power.
Issue 01 (2011-04-30)
4 Parameters
4
There are no specific parameters associated with this feature.
Parameters
Issue 01 (2011-04-30)
5 Counters
5
There are no specific counters associated with this feature.