You are on page 1of 25

FSP 150CC-GE20x Product Training Course 1 - Introduction

FSP 150CC-GE206 R4.4.x FSP 150CC-GE201 R4.3.x November 2010 V1.3

Prerequisites
Attendee should have knowledge of Telecom power and grounding practices, Ethernet, TCP-IP, PC-Windows, related test equipment and tools. i.e. our purpose is not to teach telecom, but how to apply prior knowledge and experience to FSP 150CC products. No other ADVA Optical Networking courses are required PC with serial port and admin access.

2010 ADVA Optical Networking. All rights reserved. Confidential.

Tech Support Contacts


The ADVA Optical Networking Web Page www.advaoptical.com
News And Updates

Partner Login for Our Customers And Partners


Contact support@advaoptical.com for a Login String and an Access Password that is changed monthly

The ADVA Optical Networking Service Team Support And Contacts


Europe:
t +49 (0)89 89 0665 848 f +49 (0)89 89 0665 22848 support@advaoptical.com

North America:
t 886 442 ADVA (2382) (toll-free within the US, Canada, & Mexico) t +1 806 741 8529 (elsewhere) support-usa@advaoptical.com

Asia:
t +65 6562 8148 f +65 6562 8154 support-asia@advaoptical.com
3
2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview
Introduction Application Key Functions General Characteristics Environmental Regulatory and Safety LEDs

2010 ADVA Optical Networking. All rights reserved. Confidential.

FSP 150CC-GE206
Introduction
The FSP 150CC-GE206 is a next generation Ethernet demarcation unit designed for Synchronous Ethernet and cellular backhaul applications
Main Features:
Multiple Client GbE ports Synchronous Ethernet support on all traffic carrying interfaces except of copper SFPs IEEE 1588v2 Time of Day (Future) Single E1/T1 input/output clock interface Industrial Temperature (-40 C to +65 C) 802.1ad Provider Bridge C-Tag / S-Tag Mapping MEF Compliant 3 Color Marking and 8 levels CoS 802.3ah (EFM OAM), 802.1ag (CFM), ITU-T Y.1731 OAM Network Port Protection option (1+1) Etherjack support (excluding ECPA in the initial release) 2x Personality Modules (future)

FSP 150CC-GE206 Front View


5
2010 ADVA Optical Networking. All rights reserved. Confidential.

FSP 150CC-GE206
Product Variants

GE206F 6 SFP access ports, 2 SFP network ports


0061705890 only copper SFP supported.

GE206 Hardware Rev 2.x 3 x SFP access ports, 3 x electrical access ports, 2 x SFP network ports GE206 Hardware Rev 1.x is not supported on R4.4.

2010 ADVA Optical Networking. All rights reserved. Confidential.

FSP 150CC-GE201
Introduction
The FSP 150CC-GE201 is a next generation single client port Ethernet demarcation unit designed for Synchronous Ethernet and cellular backhaul applications
Main Features:
Single Client GbE ports Synchronous Ethernet support on all traffic carrying interfaces IEEE 1588v2 Time of Day (Future) Single E1/T1 input/output clock interface Industrial Temperature (-40 C to +65 C) 802.1ad Provider Bridge C-Tag / S-Tag Mapping MEF Compliant 3 Color Marking and 8 levels CoS 802.3ah (EFM OAM), 802.1ag (CFM), ITU-T Y.1731 OAM, MEF Y.1731 SLM Network Port Protection option (1+1) Etherjack support (including ECPA)

2010 ADVA Optical Networking. All rights reserved. Confidential.

FSP 150CC-GE201
Product Variants

GE201S SyncE support and BITS timing

GE201 No SyncE, no BITS

2010 ADVA Optical Networking. All rights reserved. Confidential.

FSP 150CC-GE201

Product Variants (contd)

FNC FLASHWAVE 9410-1G SyncE support and BITS timing

All 3 product variants will have the same software load

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview
What Is It?
Layer 2 Switch Demarcation
Customer Network

Carrier Network GbE

Demarcation Point

Layer 2 switch often deployed at large enterprise customer premises as demarcation device
Good service definition (UNI) Poor Ethernet OAM (NTE)
No loopback, fault propagation, test head, etc.

Layer 2 Switch

Customer Equipment

Customer Premises

Carrier Network GbE

Demarcation Point

Dedicated Demarcation
Customer Network

Etherjack demarcation device ideal for large and small enterprise applications
Good service definition (UNI) Full suite of OAM (NTE)

Demarcation Device

Customer Equipment

< the cost and more reliable than a layer 2 switch

Customer Premises

10

2010 ADVA Optical Networking. All rights reserved. Confidential.

Application

Cellular Backhaul

ETHERNET (DATA) E1/T1 (ATM) Ethernet Uplink

STM1/OC3 (E1/T1)

Packet Switch Network


STM1/OC3 (E1/T1)

E1/T1 (TDM)

PWE3 TRAFFIC

11

2010 ADVA Optical Networking. All rights reserved. Confidential.

FSP 150CC-GE20X
Key Functions
GE201 Single client port
1 x 10/100/1000 Mbps electrical or 100/1000 Mbps optical port (SFP)

GE206 - Aggregate traffic from 6 client ports plus expansion slots


GE206 - 3 x 10/100/1000 Mbps electrical ports and 3 x 100/1000 Mbps SFP ports GE206F - 6 x 100/1000 Mbps SFP ports Supports copper SFP for 10/100/1000 Mbps operation

Network ports
2 x 1000 Mbps Optional protection

Ethernet UNI/NNI & NID


Port/VLAN based service definition and QoS VLAN Manipulation (add, remove, swap) Link layer and service layer Ethernet OAM In-band management and remote software upgrade Performance Monitoring Port and VLAN loopbacks Etherjack Service Assurance ECPA

Etherjack Features

12

2010 ADVA Optical Networking. All rights reserved. Confidential.

FSP 150CC-GE20X

Key Functions Synchronization Overview


Synchronous Ethernet (ITU-T G.8261)
Frequency lock nodes in the Ethernet Physical layer Providing fan-out from Central office to remote CES islands

Ethernet Equipment Clock (ITU-T G.8262) Ethernet Sync Messaging Channel (ITU-T G.8264)
Ethernet clock quality level messages

External Clock / Timing Inputs


Building Integrated Timing Systems (BITS)
Input Output

GE206 Single sync reference source


GE201 - Sync Reference Switching
Up to 4 sync reference sources G.781 defines an automatic selection process which can work in 2 distinct modes:
QL-enabled QL-disabled (Priority Mode) 13
2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview

FSP 150CC-GE206 Interfaces


Circuit Emulation Modules (Future)
Network Interfaces 2 x 100/1000 Optical SFP 1+1 Protection available

Management Interfaces

Time of Day ToD (future) Redundant PSUs (AC and DC) Timing (BITS Input, BITS Output) 6 Client Interfaces 3 x 10/100/1000BT RJ45 3 x 100/1000 Optical (SFP)

14

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview

FSP 150CC-GE201 Interfaces


Management Timing

LAN (RJ-45, Auto-Neg, Auto-MDIX) Serial (RJ-45 [EIA 232], ASCII)

BITS Input BITS Output

120 VAC -48 VDC +24 VDC

Redundant PSUs

10/100/1000BT RJ45 or 100/1000 Optical (SFP)

Client Interface

2 ports 10/100/1000BT RJ45, or 100/1000 Optical (SFP) 1+1 Protection

Network Interfaces

15

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview

FSP 150CC-GE20X General


17.2 W x 8.6 D x 1.75 H

Mounting Options:
Rack and wall mount kit available Stack up to 5 rows high before a heat deflector is needed

Power:
Dual hot-pluggable PSUs
AC operating voltage range: 90 to 264 VAC (AC PSU) DC operating voltage range: -36 to -72 VDC (-48VDC PSU) DC operating voltage range: +18 to +30 VDC (+24VDC PSU)

Single lockable connector for external AC/DC adapter (rear) Country specific power cords

16

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview
Environmental

FSP 150CC-GE206 Operating Temp:


-40 C to +65 C

Storage Temp: -40 to +70 C Humidity: 5% 95% non condensing No fans!

17

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview

Regulatory and Safety

Regulatory / Safety
UL/cUL/EN 60950 NEBS Level 3 FCC Part 15, Class B Industry Canada CS-03 CISPR CE Mark VCCI TV AS/NZS

18

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview
GE206 LEDs
PSU PSU

MGMT Link | Rate

Network Facility

Active/Standby

System

Access Ports Link | Rate

Access Facility

Network Ports Link | Rate

19

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview

GE206 LED Behavior


LED PSU Status Color Off Green Red Off Green Red Flashing Yellow Definition No Power PSU OK PSU Fault No system power System OK, normal operation System Failure Boot loader stage: Software download or Database backup/restore Unassigned Operating Remote Fault , Degraded Facility Loopback Link Failure Not assigned to a Protection Group Active Standby Active

System Status

Facility (Network and Access)

Off Green Yellow Yellow Flashing Red Off Green Yellow Green

Active/Standby (unprotected) Active/Standby (protected)

20

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview

GE206 LED Behavior (continued)


LED Access (4-6) Network (1-2) Link Color Off Green Flashing Green Off Yellow Green Off Green Flashing Green Off Yellow Green Off Green Flashing Green Off Yellow Green Definition No link detected Link detected Activity No link detected 100M 1000M No link detected Link detected Activity No traffic or 10M 100M 1000M No link detected Link detected Activity No link detected 10M 100M

Access (4-6) Network (1-2) Rate

Access (1-3) Link

Access (1-3) Rate

MGMT Link

MGMT Rate

21

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview
GE201 LEDs

PSU

PSU

MGMT Link | Rate

Network Facility

Active/Standby

System

Access Ports Link | Rate

Network Ports Link | Rate

22

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview

GE201 LED Behavior


LED PSU Status Color Off Green Red Off Green Red Flashing Yellow Definition No Power PSU OK PSU Fault No system power System OK, normal operation System Failure Boot loader stage: Software download or Database backup/restore Unassigned Operating Remote Fault , Degraded Facility Loopback Link Failure Not assigned to a Protection Group Active Standby Active

System Status

Facility (Network and Access)

Off Green Yellow Yellow Flashing Red Off Green Yellow Green

Active/Standby (unprotected) Active/Standby (protected)

23

2010 ADVA Optical Networking. All rights reserved. Confidential.

Product Overview

GE201 LED Behavior (continued)


LED Network (1-2) - Link Color Off Green Flashing Green Off Yellow Green Off Green Flashing Green Off Yellow Green Off Green Flashing Green Off Yellow Green Definition No link detected Link detected Activity No link detected 100M 1000M No link detected Link detected Activity No traffic or 10M 100M 1000M No link detected Link detected Activity No link detected 10M 100M

Network (1-2) - Rate

Access 1 - Link

Access 1 - Rate

MGMT Link

MGMT Rate

24

2010 ADVA Optical Networking. All rights reserved. Confidential.

End of Introduction

IMPORTANT NOTICE The content of this presentation is strictly confidential. ADVA Optical Networking is the exclusive owner or licensee of the content, material, and information in this presentation. Any reproduction, publication or reprint, in whole or in part, is strictly prohibited. The information in this presentation may not be accurate, complete or up to date, and is provided without warranties or representations of any kind, either express or implied. ADVA Optical Networking shall not be responsible for and disclaims any liability for any loss or damages, including without limitation, direct, indirect, incidental, consequential and special damages, alleged to have been caused by or in connection with using and/or relying on the information contained in this presentation. Copyright for the entire content of this presentation: ADVA Optical Networking.