FOREWORD
Ever since it's establishment in 1888 by the erstwhile British rulers in India, in the last 125 years of the history of its existence Mumbai Municipal Corporation has catered to every aspect of the citizen of Mumbai that can be conceived of. Think of Engineer Victor Tulloch, who through his unparalleled immense efforts conceived the water supply scheme fetching running over from distance of more than 100 km by constructing a dam across river Tansa, to feed the population of Mumbai, then only a few thousands in number. The items have changed with technological advancement and the works like Roller Compacted Concrete Dam at Middle Vaitarna or numerous underground tunnels for water supply and sewerage disposal, for example, have become hallmark of MCGM's dedication to the citizen of Mumbai. The challenges have always been daunting, nevertheless, always met with. Every civilization be it 5000 years old Harrappan civilization on the bank of Sindhu River, or Mumbai on the west coast of the Indian Ocean, require infrastructure like water supply and sewerage system, storm water drainage system, road, bridges, etc. and hospitals, markets, recreation centers etc. The exponentially growing population of Mumbai and the technological explosion in the field of engineering has made every aspect of contracting of works highly challenging. M.C.G.M. is one of the largest local self government in the Asian Continent. In observance of historic traditions of strong civic activism, with the change in time and living conditions to match with the urbanization, M.C.G.M. has mainly focused in providing variety of engineering services viz, storm water drain, sewerage, water supply projects, roads, bridges, solid waste management, environmental services. Beside this, the Corporation is also providing dedicated services in the Health sector by establishing numbers of Major and Peripheral hospitals. To update and modernize the mechanism being used for working on projects from the stage of conceptualization upto execution, the need was realized to revise prevailing Schedule of Rates along with specifications which were in operations with various departments and being prepared individually as per their need and used to revised at different span of time, resulting into various anomalies. Therefore, to overcome all these, it was essential to revise the schedule of rates, not only with simple mechanized revision, major changes to keep up with the pace of urbanization, civilization, construction techniques / mechanization and voluminous developments by restructuring items in the schedule as per requirements. This exercise would
provide comfort with field requirements and designs and will assist in effective checks on creation of extra items during execution. A conscious decision has been taken to keep pace with the changing time and preparation of Unified Schedule of Rates is the first step forward in this direction. Since long time, there have been demands made by the stake holders like Municipal Engineers and Contractors about non-uniformity, anomalies and discrepancies in various schedules of rates for work contracts of various departments of MCGM. Every department had its own expertise and way of functioning which got reflected in its independent schedule of rates, which, however, had no linkage with the fair market schedules of other departments and resulting into extra items and fair rates. In place of earlier 9 Schedule of Rates, the Unified Schedule of Rates is an effort & seeks to rectify the defects, discrepancies and non uniformities which will provide, not to mention about the ease and accuracy of estimation to the Engineers. In view of the enormous and voluminous nature of work, keeping time frame in perspective and above all, to ensure professionalism, the work of preparation of Unified Schedule of Rates was awarded to the eminent consultants M/s.Tata Consulting Engineers Ltd. M/s.Tata Consulting Engineers Ltd were directed to conduct a thorough factual market research for major materials from stockists/manufacturers/dealers and to study schedules of rates of Govt bodies like C.P.W.D. and P.W.D. The new Rate Analysis are based on Factual Market research done by M/s.Tata Consulting Engineers Ltd. The anomalies in rate are minimized after extensive market research and collection of quotations from reputed large scaled stockists/dealers, and also after comparison with rates of CPWD, PWD etc. The SOR is linked with its comprehensive specifications of basic important activities so as to have clarity in execution. These specifications follow a chronology of general scope of the item, material required, processing of material, construction operation, finishing and mode of measurement. All the rates are now linked to their detailed specifications and wherever required, with drawings. Though there are about 12500 items, every item is now given a Unique Code No. which will eliminate the repetition. It has been our endeavour to include all the necessary modern materials and technologies in SOR, for example, the concept of green building, which will go a long
way to have control on creation of extra items and fair rates. A salient feature of this USR is 'Starring of items' specified, categorically which can be used only at certain works or locations. Another salient features is 'Dynamic Rate System' which will be based on study of data base of quantities and bidding prices of awarded contracts on the basis of which necessary corrections can be applied to the Unified Schedule of Rates at specified intervals. The MCGM will be now in position to revise the Unified Schedule of Rates every year after incumbency period of M/s.Tata Consulting Engineers Ltd of one year, to work with and correct the system as and when necessary. I hope this 'Unified Schedule of Rates' will be a milestone in civic governance by MCGM. This self-contained publication shall be of great help and guidance to the officers engaged in the project work of MCGM.
A.M.C. (Project)
Municipal Commissioner
A. GENERAL NOTES 1. The schedule of rates will be operative from 16-09-2013 2. The unified schedule of rates includes following department: i. Buildings
ii. Water Supply Projects iii. Hydraulic Engineering iv. Sewerage Projects v. Storm Water Drainage vi. Roads vii. Bridges viii. Traffic and Signals ix. Mechanical and Electrical x. Garden Works 3. Volume-I contains USR, basic rate list and approved makes and Volume-II contains specification along with drawings wherever necessary and mandatory tests. 4. The specification of the items shall be as per latest Indian Standard Codes unless otherwise specified. 5. The rates of the items in this schedule of rates are worked out assuming average lead for Greater Mumbai area for all sorts of materials. 6. The rates are inclusive of transportation, duties, taxes and charges of all Government, Municipal or any other statutory body, applicable from time to time but exclusive of Works Contract Tax and Labour Cess levied by Government of Maharashtra. 7. The rates also includes Overheads @ 5% and Contractors Profit @10% which is inclusive of labour supervision charges, tools and plants. 8. Rates of common material and labour is attached in the Annexure-A in Volume-I. 9. The building Schedule of Rates 2013 includes the existing items of FMA, FMB 2009, SIC and Fair items, with deletion of obsolete items, merger of similar items
and value addition of new items in line with modern technology and trends in accordance with latest rules, regulation, byelaws etc. 10. As per the Government policy the use fly ash is done for framing the items of work in accordance with the latest provisions of IS Codes. Also green building items have been introduced in new schedule to minimize the consumption of energy during construction and occupancy of building and also maintaining ecological balance. 11. From safety, health and environment point of view two legged steel tubular scaffolding shall be used, without making any holes in the outer face of the building or any structure. And no extra payment shall be made for works like scaffolding, centering for any height unless otherwise specified. 12. All materials shall be as per approved list of MCGM or equivalent material having quality standards as per relevant IS codes and shall be of first quality unless otherwise specified. 13. Following basic rates are considered in the USR: i. Cement : Rs. 6,000/ MT
ii. Mild Steel : Rs. 47,400/ MT iii. HYSD Steel (Fe415) : Rs. 48,400/ MT iv. T.M.T. (Fe500) : Rs. 49,400/ MT v. Structural Steel : Rs. 53,400/ MT 14. Rates given in SOR are for estimation purpose. 15. Rates of items and specification for excavation, concrete, plaster and brickwork shall be referred from common schedule unless and otherwise not mentioned in concerned departments schedule. 16. Coding of items: The Coding procedure for Basic master material is as follows: Code will start with the common prefix of MA which stands for materials Followed by Abbreviation code for each schedule of rate for eg H.E. for Building works, SP for Sewerage, WSP for water supply and so on and so forth. The first item category in the list will be numbered as 1 The last part of the code will be a number starting with a to indicate the item number in the master list. The alpha numerics will be separated by (dash).
Code will start from abbreviation for Department name HE or WSP or SP The USR will be subdivided into chapters according to the item classification; these chapters will be numbered as 1, 2, 3 .. The items under the chapter will be numbered from 1 The sub items will be numbered as a, b, c . The code will look like CS-CW-1-a-1
Abbreviations to be used for Department Sr. No. 1 2 3 4 5 6 7 8 9 10 Department Building Schedule Roads Traffic and Signalling Bridges Water Supply Projects Hydraulic Engg. Sewerage Projects Storm Water Drains Mechanical and electrical Garden Works works/Common Abbreviation CS RW RT BW WSP HE SP SWD ME GW
B. SALIENT FEATURES OF SOR FOR BUILDING WORKS 1) 2) 3) All the rates are for all heights and levels unless noted otherwise. Chloropyrifos EC 20 has been considered for anti termite treatment. Artificial sand (crushed sand) has been considered for flooring bedding and for concrete work. 4) All the items are excluding fixtures otherwise not specified in respective item. In such case, items of Hardware section shall be used for fixtures. 5) 6) For plastering and mortar work, river sand has been considered. For plastering work all the rates are for all heights and levels and architectural decorative surface. 7) All external plaster items are including waterproofing compound except plastering item for structures like compound wall, masonary pedestals, pillars, etc. 8) Items for ashlar masonry, dewatering, self compacting concrete, vacuum dewatered concrete flooring and TMT steel bars have been introduced. 9) Rates of all the items in roofing work are inclusive of staging or scaffolding for any height. 10) 11) 12) Non-asbestos cement sheet provided in place of asbestos cement sheet roofing. Concreting of pile shall be done with RMC only. Rates of piling are inclusive of Chiseling of intermediate local boulders. No separate payment shall be made for the same 13) While estimating the quantity for Grouting of bentonite slurry in bored precast piles shall be measured as per bore dia and pile dia. Exact quantity can be measured while execution and shall be paid accordingly 14) Rates considered in concrete items are including pumping of concrete upto placing point. 15) New items like Self compacting concrete, vacuum dewatered concrete flooring and TMT steel bars have been introduced. 16) The dismantling and demolishing chapter covers only removing old items and repair work covers both removing old items and refixing the new. 17) For heritage works the rate includes the statutory charges for heritage committee and conservation architect and no extra payment will be made. 18) APP (Atactic poly-propylene) modified polymeric membrane water proofing will be used only for trial basis on approval of City Engineer and/or Chief Engineer (P&D). 19) In plumbing waterless urinals, fly ash bricks, fly ash concrete for green building concept have been introduced.
Star Rating: In view of ambiguity related to choice of quality or grade of materials and subsequent items of works to be used at Ward level projects, Centralised projects or Special projects of and for smooth functioning during planning stage of a project, the new concept of Star Rating has been introduced for building works depending on the life expectancy of building, degree of occupancy of building and comfort to the end user. The buildings or structures rated are as follows:
i.
Two Star
Hospitals, Primary Health Center, Fire Station, Crematorium, Slaughter Houses, Markets, Swimming Pools, Zoos, Chowkies, Libraries, Staff quarters and residential colonies, Public Toilets and Water tanks.
Mayors and Officers bungalow, Heritage Structures, Head Office and Engineers Hub. The items or work not marked as two star or three star are assumed to be applicable for all the star buildings or structures mentioned above.
1. The rate analysis includes some provisions such as shuttering / centering on a percentage basis. This has been brought on a rational basis using available data. 2. Since the entire area covered by Greater Mumbai falls within the coastal belt, the minimum grade of structural concrete as recommended by IRC / MORTH for severe exposure has been adopted. Items referred from common schedule or other schedule: ROAD CS-EW-15 & 16: CS-CW-1-c: CS-CW-1-a: Excavation in foundation for road works Cement Concrete - Nominal Mix of 1:3:6 -M10 P/L M-20 grade concrete for RCC work (using cement @ 330 kg/cum) - All work upto plinth level Providing and laying in position machine batched and machine mixed design mix M-40 grade Formwork Cement Mortar 1:2 (1 Cement: 2 Coarse/ Fine Sand) Cement Mortar 1:6 (1 Cement: 6 Coarse/ Fine Snad) Reinforcement for R.C.C. work all complete. -Upto plinth level Mild steel bars. Providing, detailing, fabricating and fixing at desired location using hot rolled sections and MS Plates of grade Fe 250 as per specifications and approved fabrication drawings Oil paint/ synthetic enamel paint in two coats with one coat of primer for Steelwork
CS-SS-01:
S-PN-4-c:
BRIDGE: CS-EW-1-10: CS-SS-01: Earthwork Providing and Fabricating structural steel work in rolled sections PCC Grade M15 for Open Foundation by Mixer PCC Grade M20 for Open Foundation by Mixer
CS-CW-1-b: CS-CW-1-a:
CS-CW-2-a-1:
RCC Grade M20 for Open Foundation by Batching Plant (RMC) Extra and over for providing richer RMC of M-25 grade cement concrete instead of M20 Extra and over for providing richer RMC of M-30 grade cement concrete instead of M20 Extra and over for providing richer RMC of M-35 grade cement concrete instead of M20 Extra and over for providing richer RMC of M-40 grade cement concrete instead of M20 Extra and over for providing richer RMC of M-45 grade cement concrete instead of M20 Extra and over for providing richer RMC of M-50 grade cement concrete instead of M20 Supplying, fitting and placing HYSD bar reinforcement
CS-CW-16:
CS-CW-17:
CS-CW-18:
CS-CW-19:
CS-CW-20:
CS-CW-21:
CS-CW-35-b:
Items that are referred to other SORs RW-2-01: Supplying blue trap stones of approved quality & providing the same in rubble packing 25cm. D. LIST OF UNITS USED Sr. No. 1 2 3 4 5 6 7 8 9 10 11 Length (Running Meter) Weight (Metric Tonne) Weight Kilogram Time Time (Hour) Quantity (Numbers) Quantity (Lump sum) Volume Area (Square Meter) Litre Cubic Centimeter Units Abbreviation Symbol Rmt MT Kg Shift Hr Each/No. LS Cum Sqm Ltr Cucm Each refers to a single quantity per entity Shift Refers to a time duration of 8 Hrs Remark
E. LIST OF ABBREVIATIONS AASHTO ASTM BS BOQ CBR IRC IS WC CRRI UCS WBM SAM SAMI MoRTH PCC RCC PSC HYSD EJ FBEC RE ESU American Association of State Highway and Transportation Officials American Society for Testing and Materials British Standard published by the British Standards Institution Bill of Quantities forming part of the contract California Bearing Ratio Indian Road Congress Indian Standard published by the Bureau of Indian Standards Water Cement Ratio Central Road Research Institute Unconfined Compressive Strength Water Bound Macadam Stress Absorbing Membrane Stress Absorbing Membrane Interlayer Ministry of Road Transport and Highways Plain cement concrete Reinforced cement concrete Prestressed concrete High Yield Strength Deformed Bars Expansion joints Fusion Bonded Epoxy Coating Reinforced Earth Elastomeric slab unit
INDEX
Chapter. No.
1 2 3 4 5 6 7
Chapter Code
BW-1 BW-2 BW-3 BW-4 BW-5 BW-6 BW-7
Contents
SUBSOIL INVESTIGATION FOUNDATION SUB-STRUCTURE SUPER-STRUCTURE MISCELLANEOUS ITEMS RIVER TRAINING AND PROTECTION WORKS REPAIR AND REHABILITATION BASIC RATE LIST LIST OF APPROVED MAKE
Item Range
BW-1-1 to BW-1-28 BW-2-1 to BW-2-115 BW-3-1 to BW-3-29 BW-4-1 to BW-4-72 BW-5-1 to BW-5-7 BW-6-1 to BW-6-11 BW-7-1 to BW-7-23 Appendix-A Appendix-B
Page No.
1-4 4-24 24-28 28-38 38-45 45-47 47-48 49-57
ITEM CODE
ITEM DESCRIPTION
UNIT
RATE
BW-1-01
BW-1-02
Each shift
1000.00
ITEM CODE
BW-1-07-a
ITEM DESCRIPTION
a) In M.S. Black tube 50 mm dia 150 mm. long including the cost of tube
UNIT
No. No.
RATE
300.00 150.00
BW-1-07-b b) In polythene bags by driving 100 mm size tube. Collecting undisturbed samples of soil as per specifications at any depth in M.S. black tube 100 mm dia. 450 mm long, sealed at both ends with paraffin wax and delivering the same to the testing laboratory anywhere in Greater Mumbai etc. complete as specified and directed. B) WORKS TO BE CARRIED OUT IN WATER CREEK Note: 1) The Contractors will have to submit proof of sufficient technical competence of agency undertaking items below. The Contractor will not be entitled to additional reimbursement for employing agency, if Engineer-in-charge so desires. 2) The Contractor will have to make their own arrangements for boats, barges, pontoons, floating platforms etc. for carrying out the works covered under 1.009 to 1.016 below for which no extra, payment what so ever will be made. Providing and transporting to site necessary and adequate plant and equipment for taking trial bores for subsoil investigations including conducting an initial survey for establishing datum RLS and locations of trial bores including installation of the drilling equipment of the first bore location etc. complete as specified and directed with reference to T.H.D. Shifting and locating the drilling equipment from one location to another within a lead of 500 m between successive locations including surveying the spot for establishing bore hole location, fixing ground levels with reference to datum RLS and observing ground water level during boring operation etc. complete as specified and directed.
BW-1-08
No.
450.00
BW-1-09
Each Unit
45000.00
BW-1-10
Each Unit
3500.00
Taking trial bores upto 150 mm dia. for subsoil investigation through overburden and soil of all sorts including cleaning the bottom of holes before taking field tests at various depths etc. complete as specified and directed. BW-1-11-a a) Depth upto 6.0 m below ground surface BW-1-11-b b) Depth beyond 6.0 m upto 20.0 m below ground surface Taking trial bores for subsoil investigation through rock using rotary drilling equipment with NX size diamond core drilling bits to obtain approximately 54 mm dia. rock cores including provision of wooden boxes for storage of cores, indexing the core samples at site of work and conveying the same to the head quarters of concerned office etc. complete as specified and directed. BW-1-12-a a) Depth upto to 10.0 m below ground surface. BW-1-12-b b) Depth beyond 10.0 m upto 20.00 m below ground surface BW-1-12-c c) Depth beyond 20 m to 30 m Taking trial bores for sub soil investigation through rock using rotary drilling equipment with NX size diamond core drillng bits and double tube core barrel to obtain approximately 54 mm dia. rock cores including provision of wooden boxes for storage of cores, indexing the core samples at site of work and conveying the same to the headquarters of concerned office etc. complete as specified and directed. BW-1-13-a a) Depth upto 10.0 m below ground surface BW-1-13-b b) Depth beyond 10.0 m upto 20.00 m below ground surface
Rmt Rmt
1600.00 2100.00
Rmt Rmt
1900.00 2400.00
ITEM CODE
BW-1-14
ITEM DESCRIPTION
Conducting Standard penetration test as per Specifications in soil at various levels of bore holes and reporting the results in the approved format etc. complete as specified and directed. Collecting disturbed samples of soil from bore holes as per specifications and delivering the same to the testing laboratory anywhere in Greater Mumbai as directed etc. complete as specified and directed.
UNIT
No.
RATE
300.00
BW-1-15-a
a) In M.S. Black tube 50 mm dia 150 mm. long including the cost of tube
No. No.
300.00 150.00
BW-1-15-b b) In polythene bags by driving 100 mm size tube. Collecting undisturbed samples of soil as per specifications at any depth in M.S. black tube 100 mm dia. 450 mm long, sealed at both ends with paraffin wax and delivering the same to the testing laboratory anywhere in Greater Mumbai etc. complete as specified and directed. Collecting soil samples and sub-soil water samples in glass or plastic bottles I jars from trial bore holes and getting the same chemically analyzed in an approved laboratory for determination of sulphate and chloride contents and pH value etc. complete as specified and directed. Carrying out Plate Load Test complete with necessary and adequate Kentledge loads, equipments and instruments etc. as per specifications for determination of bearing capacity of soil etc. complete as specified and directed and submitting reports in duplicate. (C) SUB-SURFACE EXPLORATIONS
BW-1-16
No.
450.00
BW-1-17
No.
100.00
BW-1-18
No.
75000.00
BW-1-19
Preparing and submitting reports and drawings in triplicate for location depth and details of underground pipe lines, cables and services as Each existing according to standard technique as specified upto whatever depth Trench of excavation and including all equipment, material, and labour of technical expertise as directed excluding excavation.
15000.00
Taking trial pit in soil of all sorts excluding rock including shoring and strutting as required, collecting disturbed & undisturbed samples at 1 m intervals and trial depth, collecting water samples & transporting all soil & water sample to lab., visual inspection for description of strata / recording water table encountered, dewatering manually and refilling at end etc. complete as specified and directed. BW-1-20-a a) Upto 2 mt. depth BW-1-20-b b) 2 m to 4 m depth BW-1-20-c c) 4 m to 6 m depth (D) LABORATORY TESTING Carrying out tests as per specifications for determination of: i) Natural moisture Content (NMC) of soil by Oven Drying method ii) Atterberg limits a) Liquid limit b) Plastic limit c) Shrinkage limit iii) Grain size analysis including grain size distribution curves in accordance with IS 2720 (part 4) a) Sieve Analysis b) Hydrometer Analysis iv) In-situ density of soil samples v) Specific gravity
ITEM CODE
BW-1-21-i
ITEM DESCRIPTION
vi) Unconfined compressive strength of rock samples, including determination of percentage of water absorption and density. Carrying out Vane Shear Test at various levels of bore holes as per specifications laid down in IS:4434 and reporting results thereof as per prescribed proforma etc. complete as specified and directed. (Including mobilization of necessary and adequate equpment) Providing and transporting to site necessary and adequate plant and equipment for performing DPT etc. complete as specified and directed. Shifting and locating plant and equipment from one location to another location for performing DPT etc. complete as specified and directed.
UNIT
No.
RATE
500.00
BW-1-22
No.
12000.00
BW-1-23
7000.00
BW-1-24
1000.00
Performing Dynamic cone penetration test in accordance with IS 4968 and reporting the results in the approved format etc. complete as specified and directed. a) Conducting probing test by using lighter probing rod and light weight BW-1-25-a hammer (18 kg) BW-1-25-b b) Conducting probing test using a-drill and SPT hammer (65 kg) Conducting Direct Shear Test in accordance with IS:2720 (part 13) and BW-1-26 reporting results thereof as per prescribed proforma etc complete as specified and directed. Conducting Consolidation test on undisturbed soil sample or soil sample compacted to specified density in accordance with IS 2720 ( part-15 BW-1-27 ),reporting results including unit weights, specific gravity, e-log p curve, virgin curve, PO, eo, Cc, Cv and mv for all pressure increments etc. complete as specified and directed. Conducting Unconfined compression test on undisturebed soil samples or soil samples compacted to specified density in accordance with IS : BW-1-28 2720 (part 10) and reporting results thereof as per prescribed Proforma etc. complete as specified and directed.
No.
900.00
No.
350.00
FOUNDATION A) EXCAVATION
BW-2-1 BW-2-1-a BW-2-1-b Excavation for foundation in any type of Marshy or creek land upto a depth of 3.0 m by Manual means Cost for dewatering , where required for Item No. BW -2-1 Cost for Shoring & strutting , where required for Item No. BW -2-1 It is assumed that Marshy Soil will be available upto 3 m depth only. For deeper excavation below 3 m depth, refer Common Schedule Earth Work Chapter Excavation for foundation in any type of Marshy or creek land upto a depth of 3.0 m by Mechanical Means Cost for dewatering , where required for Item No. BW -2.1.2 Cost for Shoring & strutting , where required for Item No. BW -2.1.2 It is assumed that Marshy Soil will be available upto 3 m depth only. For deeper excavation below 3 m depth, refer Common Schedule Earth Work Chapter Back Filling in Marshy Foundation Pits Cum Cum Cum 427.00 96.60 48.30
BW-2-3
Cum
256.00
ITEM CODE
ITEM DESCRIPTION
Excavation for foundation in earth, soil of all sorts excluding rock by any method as required and / or directed including shoring and strutting as necessary, removing down vegetation, bailing out water manually, removing the excavated materials upto a safe distance as directed including all lifts and leads, preparing the bed for foundation, backfilling with approved materials, ramming, watering and disposing off the surplus excavated material and cleaning the site etc. complete as specified and directed (0 to 2m.) Excavation for foundation in earth, soil of all sorts excluding rock by any method as required and / or directed including shoring and strutting as necessary, removing down vegetation, bailing out water manually, removing the excavated materials upto a safe distance as directed including all lifts and leads, preparing the bed for foundation, backfilling with approved materials, ramming, watering and disposing off the surplus excavated material and cleaning the site etc. complete as specified and directed (above 2m upto 4m.) Excavation for foundation in earth, soil of all sorts excluding rock by any method as required and / or directed including shoring and strutting as necessary, removing down vegetation, bailing out water manually, removing the excavated materials upto a safe distance as directed including all lifts and leads, preparing the bed for foundation, backfilling with approved materials, ramming, watering and disposing off the surplus excavated material and cleaning the site etc. complete as specified and directed (above 4m upto 6m.) E.O for Excavation for foundation in soft rock by any method as required and / or directed including bailing out water manually, removing the excavated materials upto a safe distance as directed including all lifts and leads, preparing the bed for foundation, backfilling with approved materials, watering and disposing off the surplus excavated materials and cleaning the site etc. completed as specified and directed (any depth). E.O for Excavation for foundation in hard rock by blasting including bailing out water manually, removing the excavated materials upto a safe distance as directed, stacking the serviceable materials neatly and disposing off the unserviceable materials as directed including all leads and lifts, preparing the bed for foundation backfilling with approved materials and disposing off the surplus excavated materials and cleaning the site etc. complete as specified and directed (any depth). Excavation for foundation in hard rock by chiseling / wedging / line drilling without blasting including bailing out water manually, removing the excavated materials upto a safe distance as directed, stacking the serviceable materials neatly and disposing off the unserviceable materials as directed including all leads and lifts, preparing the bed for foundation, backfilling with approved materials and disposing off the surplus excavated materials and cleaning the site etc. complete as specified and directed (any depth). Filling Annular Space Around Footing in Rock (Lean cement concrete 1:3:6 nominal mix). Sand Filling in Foundation Trenches as per Drawing & Technical Specification
UNIT
RATE
BW-2-4
BW-2-5
BW-2-6
BW-2-7
BW-2-8
BW-2-9
BW-2-10 BW-2-11
Cum Cum
4696.00 1766.00
ITEM CODE
ITEM DESCRIPTION
UNIT
RATE
BW-2-12
Dewatering on Horse Power basis by using water pumps including diversion of streams, providing earthen bunds, cofferdams etc. as may necessary for foundation and other parts of structure including pumping HP per hr out water during and after excavation until work for foundation and substructure above natural water is completed etc. completed as specified and directed.
Refer CSEW-10
MASONRY ITEMS
Providing and laying Dry Rubble stone packing having thickness 230 mm and above in foundation including hand packing in regular line and level, BW-2-13 filling interstices with small pieces of stone, thoroughly ramming and consolidating including watering as necessary etc. complete as specified and directed. Providing Coursed rubble masonry 1st sort of trap stone in cement BW-2-14 mortar 1:5 in superstructure including scaffolding, racking out I striking out joints, watering etc. complete as directed and specified. Providing random rubble stone masonry of trap stone in cement mortar 1:3 in foundation / sub structure as per drawing and specification striking joints of non exposed faces and pointing the exposed faces with cement mortar 1:3 including scaffolding and watering including bailing out water manually etc. complete. BW-2-15-a Square Rubble Coursed rubble masonry( first sort ) BW-2-15-b Random Rubble Masonry
Cum
1219.00
Cum
3992.00
Cum Cum
4776.00 4611.00
ITEM CODE
ITEM DESCRIPTION
N' for various grade of concrete considered in the schedule of Rate. M-45 = 10.8 bags/Cum. M-25= 8.2 bags I Cum. M-40 = 10.8 bags/Cum. M-20 =7.20 bags / Cum. M-35 = 10.2 bags/Cum. M-15= 6.40 bags I Cum. M-30 = 9.2 bags/Cum. M-10 =5.50 bags / Cum. Providing and laying in position M-10 plain cement concrete to fill up loose pockets of foundations bed for making required levels, annular filling around abutments, piers, columns for foundation. Providing and placing in position controlled cement concrete of M-15 grade for foundation work with minimum cement 400 kg./cum. and water cement ratio not exceeding 0.4 for PCC raft foundation slab with V notches Sloped / flat / strlp footings, pile caps tie beams to required lines / levels including leveling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed. Providing and placing in position controlled cement concrete of M-20 grade for foundation work with minimum cement 400 kg./cum. and water cement ratio not exceeding 0.4 for PCC raft foundation slab with V notches Sloped / flat / strlp footings, pile caps tie beams to required lines / levels including leveling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed.
UNIT
RATE
BW-2-16
4775.00
BW-2-17
Cum
5218.00
BW-2-18
Cum
5609.00
Providing and placing in position controlled cement concrete of M-20 grade for foundation work with minimum cement 400 kg./cum. and water cement ratio not exceeding 0.4 for RCC raft foundation slab with V notches Sloped / flat / strlp footings, pile caps tie beams to required lines / levels including leveling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed but excluding reinforcement. Using concrete mixer BW-2-19-a a) With Batching Plant, Transit Mixer and Concrete Pump BW-2-19-b b) Providing and placing in position controlled cement concrete of M-25 grade for foundation work with minimum cement 400 kg./cum. and water cement ratio not exceeding 0.4 for PCC raft foundation slab with V notches Sloped / flat / strlp footings, pile caps tie beams to required lines / levels including leveling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed. Using concrete mixer BW-2-20-a a) With Batching Plant, Transit Mixer and Concrete Pump BW-2-20-b b) Providing and placing in position controlled cement concrete of M-25 grade for foundation work with minimum cement 400 kg./cum. and water cement ratio not exceeding 0.4 for RCC raft foundation slab with V notches Sloped / flat / strlp footings, pile caps tie beams to required lines / levels including leveling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed but excluding reinforcement. Using concrete mixer BW-2-21-a a) With Batching Plant, Transit Mixer and Concrete Pump BW-2-21-b b) Providing and placing in position controlled cement concrete of M-30 grade for foundation work with minimum cement 400 kg./cum. and water cement ratio not exceeding 0.4 for PCC raft foundation slab with V notches Sloped / flat / strlp footings, pile caps tie beams to required lines / levels including leveling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed.
Cum Cum
5646.00 6019.00
Cum Cum
5991.00 6210.00
Cum Cum
6033.00 6210.00
ITEM CODE
BW-2-22-a a) BW-2-22-b b)
ITEM DESCRIPTION
Using concrete mixer With Batching Plant, Transit Mixer and Concrete Pump
UNIT
Cum Cum
RATE
6020.00 6541.00
Providing and placing in position controlled cement concrete of M-30 grade for foundation work with minimum cement 400 kg./cum. and water cement ratio not exceeding 0.4 for RCC raft foundation slab with V notches Sloped / flat / strlp footings, pile caps tie beams to required lines / levels including leveling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed but excluding reinforcement. BW-2-23-a a) BW-2-23-b b) Using concrete mixer With Batching Plant, Transit Mixer and Concrete Pump Cum Cum 6042.00 6606.00
Providing and placing in position controlled cement concrete of M-35 grade for foundation work with minimum cement 400 kg./cum. and water cement ratio not exceeding 0.4 for RCC raft foundation slab with V notches Sloped / flat / strlp footings, pile caps tie beams to required lines / levels including leveling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed but excluding reinforcement. BW-2-24-a a) BW-2-24-b b) Using concrete mixer With Batching Plant, Transit Mixer and Concrete Pump Cum Cum 6122.00 6779.00
BW-2-25
Providing and placing in position controlled cement concrete of M-40 grade for foundation work with minimum cement 400 kg./cum. and water cement ratio not exceeding 0.4 for RCC raft foundation slab with V notches Sloped / flat / strlp footings, pile caps tie beams to required lines / levels including leveling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed but excluding reinforcement.
Cum
7017.00
ITEM CODE
ITEM DESCRIPTION
Providing and installing in position controlled concrete of grade M-35 (Batching Plant, Transit Mixer and Concrete Pump ) with minimum cement content as 400 kg/cum. and W.C. ratio not exceeding 0.40 for RCC work in cast-in-situ bored piles each of load capacity as per design and of specified diameter using maximum 20 mm size of aggregate including boring through aIl strata except rock, including placing of concrete by tremie arrangement through mild steel casing to the required depth through all strata except rock, compaction as necessary with drawl of mild steel casing including chipping / dressing of piles to required levels, cleaning the reinforcement, removal of excavated earth with all lifts and lead upto 1000 m. etc. complete as specified and directed (Excluding reinforcement). 1) 400 mm dia 2) 450 mm dia 3) 500 mm dia 4) 550 mm dia 5) 600 mm dia 6) 650 mm dia 7) 700 mm dia 8) 750 mm dia 9) 800 mm dia 10) 900 mm dia 11) 1000 mm dia 12)1100mmdia 13) 1200 mm dia Extra over rates quoted in items BW-2-26 and BW-2-27 for chiseling through soft / weathered rock / hard rock / large boulders / old foundations / masonry / concrete etc. using a chisel weighing not less than 750 kg.
UNIT
RATE
BW-2-27-a BW-2-27-b BW-2-27-c BW-2-27-d BW-2-27-e BW-2-27-f BW-2-27-g BW-2-27-h BW-2-27-i BW-2-27-j BW-2-27-k BW-2-27-l BW-2-27-m
Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt
1245.00 1575.00 1945.00 2353.00 2801.00 3287.00 3812.00 4376.00 4979.00 6302.00 7780.00 9414.00 11203.00
BW-2-28-a BW-2-28-b BW-2-28-c BW-2-28-d BW-2-28-e BW-2-28-f BW-2-28-g BW-2-28-h BW-2-28-i BW-2-28-j BW-2-28-k BW-2-28-l BW-2-28-m BW-2-28-n
1) 400mmdia 2) 450 mm dia 3) 500 mm dia 4) 550 mm dia 5) 600 mm dia 6) 650 mm dia 7) 700 mm dia 8) 750 mm dia 9) 800 mm dia 10) 850 mm dia 11) 900 mm dia 12) 1000 mm dia 13) 1100 mm dia 14) 1200 mm dia Empty boring through over burden including road crust upto the bottom of BW-2-3-4 pile cap for all diameters of piles. Chipping and dressing of the RCC piles to remove surplus concrete above cut off level without damaging the projecting reinforcement including clearing reinforcement and removing the dismantled materials etc. complete as specified and directed. BW-2-29-a 1) 400 mm dia BW-2-29-b 2) 450 mm dia BW-2-29-c 3) 500 mm dia BW-2-29-d 4) 550 mm dia BW-2-29-e 5) 600 mm dia BW-2-29-f 6) 650 mm dia
Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt
786.00 995.00 1228.00 1486.00 1769.00 2076.00 2407.00 2764.00 3144.00 3550.00 3980.00 4913.00 5945.00 7075.00 1806.00
ITEM CODE
BW-2-29-g BW-2-29-h BW-2-29-i BW-2-29-j BW-2-29-k BW-2-29-l BW-2-29-m 7) 700 mm dia 8) 750 mm dia 9) 800 mm dia 10) 900 mm dia 11) 1000 mm dia 12) 1100 mm dia 13) 1200 mm dia
ITEM DESCRIPTION
UNIT
Rmt Rmt Rmt Rmt Rmt Rmt Rmt
RATE
338.00 388.00 442.00 499.00 559.00 690.00 835.00
Providing and installing in position controlled concrete of grade M-35 (Batching Plant, Transit Mixer and Concrete Pump ) with minimum cement content as 400 kg/cum. and W.C. ratio not exceeding 0.40 for RCC work in driven cast-in-situ vertical piles each of load capacity as per design and of specified diameter using maximum 20 mm size of aggregate including boring through aIl strata except rock, including placing of concrete by tremie arrangement through mild steel casing to the required depth through all strata except rock, compaction as necessary with drawl of mild steel casing including chipping / dressing of piles to required levels, cleaning the reinforcement etc. complete as specified and directed (Excluding reinforcement). BW-2-30-a a) BW-2-30-b b) BW-2-30-c c) 750 mm dia 1000 mm dia 1200 mm dia Rmt Rmt Rmt 4174.00 6865.00 9989.00
BW-2-31
Providing and placing in position M-35 RCC precast piles of 500 mm dia in preformed bores made with hydraulic rig drilling / boring through all type of strata including hard rock using portland cement with minimum cement content as 400 kg. Per cum. and water cement ratio not exceeding 0.40 each with a load capacity as per design, transporting the precast pile from casting yard to site of work, hoisting and holding the pile truly vertical with the help of crane of required capacity, placing the pile in position including grouting the annular space with cement grout (1 :2) (1 cement, 2 fine sand) between the pile and the preformed bore including cutting off the surplus length of pile and dressing neatly including providing M.S. black tube 30 mm dia through the centre of pile for grouting etc. complete including cost of all boring work through all type of strata as specified and directed but excluding the cost of reinforcement. Providing and placing in position M-35 RCC precast piles of 600 mm dia in preformed bores made with hydraulic rig drilling / boring through all type of strata including hard rock using portland cement with minimum cement content as 400 kg. Per cum. and water cement ratio not exceeding 0.40 each with a load capacity as per design, transporting the precast pile from casting yard to site of work, hoisting and holding the pile truly vertical with the help of crane of required capacity, placing the pile in position including grouting the annular space with cement grout (1 :2) (1 cement, 2 fine sand) between the pile and the preformed bore including cutting off the surplus length of pile and dressing neatly including providing M.S. black tube 30 mm dia through the centre of pile for grouting etc. complete including cost of all boring work through all type of strata as specified and directed but excluding the cost of reinforcement.
Rmt
2508.00
BW-2-32
Rmt
2788.00
10
ITEM CODE
ITEM DESCRIPTION
UNIT
RATE
BW-2-33
Providing and placing in position M-35 RCC precast piles of 450 mm dia in preformed bores made with hydraulic rig drilling / boring through all type of strata including hard rock using portland cement with minimum cement content as 400 kg. Per cum. and water cement ratio not exceeding 0.40 each with a load capacity as per design, transporting the precast pile from casting yard to site of work, hoisting and holding the pile truly vertical with the help of crane of required capacity, placing the pile in position including grouting the annular space with cement grout (1 :2) (1 cement, 2 fine sand) between the pile and the preformed bore including cutting off the surplus length of pile and dressing neatly including providing M.S. black tube 30 mm dia through the centre of pile for grouting etc. complete including cost of all boring work through all type of strata as specified and directed but excluding the cost of reinforcement.
Rmt
2255.00
BW-2-34
Providing and placing in position M-35 RCC precast piles of 750 mm dia in preformed bores made with hydraulic rig drilling / boring through all type of strata including hard rock using portland cement with minimum cement content as 400 kg. Per cum. and water cement ratio not exceeding 0.40 each with a load capacity as per design, transporting the precast pile from casting yard to site of work, hoisting and holding the pile truly vertical with the help of crane of required capacity, placing the pile in position including grouting the annular space with cement grout (1 :2) (1 cement, 2 fine sand) between the pile and the preformed bore including cutting off the surplus length of pile and dressing neatly including providing M.S. black tube 30 mm dia through the centre of pile for grouting etc. complete including cost of all boring work through all type of strata as specified and directed but excluding the cost of reinforcement. Providing and placing in position M-35 RCC precast piles of 1000 mm dia in preformed bores made with hydraulic rig drilling / boring through all type of strata including hard rock using portland cement with minimum cement content as 400 kg. Per cum. and water cement ratio not exceeding 0.40 each with a load capacity as per design, transporting the precast pile from casting yard to site of work, hoisting and holding the pile truly vertical with the help of crane of required capacity, placing the pile in position including grouting the annular space with cement grout (1 :2) (1 cement, 2 fine sand) between the pile and the preformed bore including cutting off the surplus length of pile and dressing neatly including providing M.S. black tube 30 mm dia through the centre of pile for grouting etc. complete including cost of all boring work through all type of strata as specified and directed but excluding the cost of reinforcement.
4294.00
BW-2-35
6954.00
Providing and installing in position permanent M.S. liners for piles of specified diameter and fabricated from 6.0 to 8.0mm thick plates as per BW-2-36 detailed drawings and designs including cutting, bending to required shape, welding, painting with Red Oxide paint etc. complete as specified and directed. Levelling course for Pile cap - Providing and laying of PCC M15 BW-2-37 levelling course 100mm thick below the pile cap. Providing and cutting bending, hooking, laying in position and tying Mild steel / HYSD bars for reinforcement as per detailed drawings for R.C.C.work. BW-2-38-a a) HYSD bars BW-2-38-b b) Mild Steel bars
MT
78465.00
Cum
4150.00
MT MT
62100.00 61199.00
11
ITEM CODE
UNIT
RATE
Providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. Well. BW-2-39-a Assuming depth of water 1.0 m and height of island to be 1.25m. BW-2-39-b Assuming depth of water 4.0 m and height of island 4.5 m. Providing and constructing one span service road to reach island location BW-2-40 from one pier location to another pier location Providing, fabricating and setting out in requisite position Mild steel weighing 40 kg per metre cutting edge for RCC wells including cutting, bending to required shape as per detailed drawings and designs including bolting, revetting or welding sections, dowels for anchoring the cutting edge to well curb etc. complete as specifeid and directed. Well curb Providing and placing in position controlled cement concrete in M-25 grade in well curbs with minimum cement content as 400 kg/cum. water cement ratio not exceeding 0.40 and maximum size of coarse aggregate not exceeding 20 mm including necessary formwork to give form finish surface, compacting by vibrators, curing etc. complete as specified and directed. (Excluding reinforcement). a) Using concrete mixer With Batching Plant, Transit Mixer and Concrete Pump
BW-2-41
MT
83902.00
BW-2-42-a
Cum Cum
6979.00 7237.00
BW-2-42-b b)
Providing and placing in position controlled cement concrete in M-30 grade in well curbs with minimum cement content as 400 kg/cum. water cement ratio not exceeding 0.40 and maximum size of coarse aggregate not exceeding 20 mm including necessary formwork to give form finish surface, compacting by vibrators, curing etc. complete as specified and directed. (Excluding reinforcement). Using concrete mixer BW-2-43-a a) With Batching Plant, Transit Mixer and Concrete Pump BW-2-43-b b) Providing and placing in position controlled cement concrete in M-35 grade in well curbs with minimum cement content as 400 kg/cum. water cement ratio not exceeding 0.40 and maximum size of coarse aggregate not exceeding 20 mm including necessary formwork to give form finish surface, compacting by vibrators, curing etc. complete as specified and directed. (Excluding reinforcement). BW-2-44-a a) Using concrete mixer With Batching Plant, Transit Mixer and Concrete Pump
Cum Cum
7006.00 8995.00
Cum Cum
7133.00 7822.00
BW-2-44-b b)
Well steining Providing and placing in position controlled cement concrete of M-15 grade in PCC well steining as per detailed design and drawings with minimum cement content of 400 kg/cum, water cement ratio not exceeding 0.40 andmaximum size of aggregate not exceeding 20 mm including form work to give form finish surface, compacting by vibrators, necessary bracings and curing etc. complete as specified and directed.
BW-2-45
Cum
5519.00
12
ITEM CODE
ITEM DESCRIPTION
Providing and placing in position controlled cement concrete of M-20 grade in PCC well steining as per detailed design and drawings with minimum cement content of 400 kg/cum, water cement ratio not exceeding 0.40 andmaximum size of aggregate not exceeding 20 mm including form work to give form finish surface, compacting by vibrators, necessary bracings and curing etc. complete as specified and directed. Providing and placing in position controlled cement concrete of M-20 grade in RCC well steining as per detailed design and drawings with minimum cement content of 400 kg/cum, water cement ratio not exceeding 0.40 andmaximum size of aggregate not exceeding 20 mm including form work to give form finish surface, compacting by vibrators, necessary bracings and curing etc. complete as specified and directed. (Excluding reinforcement)
UNIT
RATE
BW-2-46
Cum
5933.00
BW-2-47-a
a)
Using concrete mixer With Batching Plant, Transit Mixer and Concrete Pump
Cum Cum
5972.00 6367.00
BW-2-47-b b)
Providing and placing in position controlled cement concrete of M-25 grade in PCC well steining as per detailed design and drawings with minimum cement content of 400 kg/cum, water cement ratio not exceeding 0.40 and-maximum size of aggregate not exceeding 20 mm including form work to give form finish surface, compacting by vibrators, necessary bracings and curing etc. complete as specified and directed. BW-2-48-a a) Using concrete mixer With Batching Plant, Transit Mixer and Concrete Pump Cum Cum 6353.00 6568.00
BW-2-48-b b)
Providing and placing in position controlled cement concrete of M-25 grade in RCC well steining as per detailed design and drawings with minimum cement content of 400 kg/cum, water cement ratio not exceeding 0.40 andmaximum size of aggregate not exceeding 20 mm including form work to give form finish surface, compacting by vibrators, necessary bracings and curing etc. complete as specified and directed. (Excluding reinforcement) BW-2-49-a a) Using concrete mixer With Batching Plant, Transit Mixer and Concrete Pump Cum Cum 6397.00 6634.00 BW-2-49-b b)
Providing and placing in position controlled cement concrete of M-30 grade in PCC well steining as per detailed design and drawings with minimum cement content of 400 kg/cum, water cement ratio not exceeding 0.40 andmaximum size of aggregate not exceeding 20 mm including form work to give form finish surface, compacting by vibrators, necessary bracings and curing etc. complete as specified and directed. BW-2-50-a a) Using concrete mixer Cum Cum 6398.00 6918.00
With Batching Plant, Transit Mixer and Concrete Pump BW-2-50-b b) Providing and placing in position controlled cement concrete of M-30 grade in RCC well steining as per detailed design and drawings with minimum cement content of 400 kg/cum, water cement ratio not exceeding 0.40 andmaximum size of aggregate not exceeding 20 mm including form work to give form finish surface, compacting by vibrators, necessary bracings and curing etc. complete as specified and directed. (Excluding reinforcement) BW-2-51-a a) Using concrete mixer With Batching Plant, Transit Mixer and Concrete Pump
Cum Cum
6422.00 6987.00
BW-2-51-b b)
13
ITEM CODE
ITEM DESCRIPTION
Providing and placing in position controlled cement concrete of M-35 grade in RCC well steining as per detailed design and drawings with minimum cement content of 400 kg/cum, water cement ratio not exceeding 0.40 and maximum size of aggregate not exceeding 20 mm including form work to give form finish surface, compacting by vibrators, necessary bracings and curing etc. complete as specified and directed (Excluding reinforcement).
UNIT
RATE
BW-2-52-a
a)
Cum Cum
6539.00 7170.00
With Batching Plant, Transit Mixer and Concrete Pump BW-2-52-b b) Providing and placing in position controlled cement concrete of M-40 grade in RCC well steining as per detailed design and drawings with minimum cement content of 400 kg/cum, water cement ratio not exceeding 0.40 and maximum size of aggregate not exceeding 20 mm including form work to give form finish surface, compacting by vibrators, necessary bracings and curing etc. complete as specified and directed (Excluding reinforcement). BW-2-53 - With Batching Plant, Transit Mixer and Concrete Pump Sinking of 6 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Sandy soil BW-2-54-a BW-2-54-b Depth below bed level upto 3.0 M Beyond 3m upto 10m depth Beyond 10m upto 20m BW-2-54-c Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter Beyond 20m upto 30 m BW-2-54-d BW-2-54-e Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement and Labour . Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of BW-2-54-f sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement BW-2-54-g and Labour . Clayey soil ( 6m dia. Well ) BW-2-55-a BW-2-55-b Depth below bed level upto 3.0 M Beyond 3m upto 10m depth Beyond 10 m upto 20 m BW-2-55-c Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter Beyond 20m upto 30 m BW-2-55-e BW-2-55-f Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering of the cost, if required
Cum
7494.00
Rmt Rmt
3296.00 4594.00
Rmt
6067.00
Rmt
11378.00 13654.00
Rmt Rmt
4623.00 10132.00
Rmt Rmt
13383.00 14052.00
Rmt Rmt
25104.00 32949.00
14
ITEM CODE
BW-2-55-g
ITEM DESCRIPTION
Add 25% of cost for Kentledge including supports, loading arrangement and Labour ). Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering, if required Add 20% of cost for Kentledge including supports, loading arrangement and Labour). Soft rock (6m dia well ) Depth of soft rock strata upto 3m Hard rock (6m dia well )
UNIT
Rmt
RATE
31380.00
BW-2-56
Rmt
16577.00
BW-2-57
Depth of soft rock strata upto 3m Sinking of 7 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Sandy soil
Rmt
16482.00
BW-2-58-a BW-2-58-b
Depth below bed level upto 3.0 M Beyond 3m upto 10m depth Beyond 10m upto 20m Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement and Labour) . Beyond 30m upto 40 m
Rmt Rmt
4831.00 6367.00
BW-2-58-c
Rmt
8409.00
BW-2-58-d BW-2-58-e
Rmt Rmt
15772.00 18927.00
Add 10% for every additional meter depth of sinking over the rate of BW-2-58-f sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement, BW-2-58-g and Labour etc. Clayey soil ( 7m dia. Well ) BW-2-59-a Depth below bed level upto 3.0 M
Rmt Rmt
37470.00 44964.00
Rmt Rmt
6367.00 9071.00
BW-2-59-b Beyond 3m upto 10m depth Beyond 10 m upto 20 m BW-2-59-c Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter Beyond 20m upto 30 m BW-2-59-e BW-2-59-f BW-2-59-g Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering on the cost, if required Add 25% of cost for Kentledge including supports, loading arrangement and Labour ). Beyond 30m upto 40 m
Rmt Rmt
11980.00 12579.00
15
ITEM CODE
BW-2-59-h BW-2-59-i BW-2-59-j
ITEM DESCRIPTION
Add 10% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering, if required Add 20% of cost for Kentledge including supports, loading arrangement and Labour). Soft rock ( 7m dia well ) Depth of soft rock strata upto 3m Hard rock ( 7m dia well )
UNIT
Rmt Rmt
RATE
53389.00 67270.00 64067.00
BW-2-60
Rmt
13392.00
BW-2-61
Depth upto 3 m Sinking of 8 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level.
Rmt
19719.00
BW-2-62-d BW-2-62-e
Sandy soil Depth below bed level upto 3.0 M Beyond 3m upto 10m depth Beyond 10m upto 20m Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement and Labour . Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement, and Labour etc. Clayey soil ( 8m dia. Well ) Depth upto 3.0 M Beyond 3m upto 10m depth Beyond 10 m upto 20 m Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add for dewatering @ 5% of cost, if required. Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering on the cost, if required Add 25% of cost for Kentledge including supports, loading arrangement and Labour ). Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering, if required Add 20% of cost for Kentledge including supports, loading arrangement and Labour). Soft rock ( 8m dia well ) Depth in soft rock strata upto 3m Hard rock ( 8m dia well ) Depth in hard rock strata upto 3 m
Rmt Rmt
17881.00 21457.00
16
ITEM CODE
ITEM DESCRIPTION
Sinking of 9 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level.
UNIT
RATE
BW-2-66-d BW-2-66-e
Sandy soil Depth below bed level upto 3.0 M Beyond 3m upto 10m depth Beyond 10m upto 20m Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement and Labour . Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement, and Labour etc. Clayey soil ( 9m dia. Well ) Depth below bed level upto 3.0 M Beyond 3m upto 10m depth Beyond 10 m upto 20 m Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add for dewatering @ 5% of cost, if required. Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering on the cost, if required Add 25% of cost for Kentledge including supports, loading arrangement and Labour ). Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering, if required Add 20% of cost for Kentledge including supports, loading arrangement and Labour). Soft rock ( 9m dia well ) Depth upto 3m Hard rock ( 9m dia well ) Depth of hard rock strata upto 3 m Sinking of 10 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level.
Rmt Rmt
19582.00 23498.00
Sandy soil BW-2-70-a Depth below bed level upto 3.0 M BW-2-70-b Beyond 3m upto 10m depth Beyond 10m upto 20m Add 5% for every additional meter depth of sinking over the rate of sinking BW-2-70-c for the previous meter Beyond 20m upto 30 m
17
ITEM CODE
BW-2-70-d BW-2-70-e
ITEM DESCRIPTION
Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement and Labour . Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement, and Labour etc. Clayey soil (10m dia. Well ) Depth below bed level upto 3.0 M Beyond 3m upto 10m depth Beyond 10 m upto 20 m Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add for dewatering @ 5% of cost, if required. Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering on the cost, if required Add 25% of cost for Kentledge including supports, loading arrangement and Labour ). Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering, if required Add 20% of cost for Kentledge including supports, loading arrangement and Labour). Soft rock (10m dia well ) Depth of soft rock strata upto 3m Hard rock (10m dia well ) Depth of hard rock strata upto 3 m Sinking of 11 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level.
UNIT
Rmt Rmt
RATE
20802.00 24963.00
Rmt Rmt
Rmt Rmt
18728.00 25774.00
Sandy soil BW-2-74-a Depth from bed level upto 3.0 M BW-2-74-b Beyond 3m upto 10m depth Beyond 10m upto 20m Add 5% for every additional meter depth of sinking over the rate of sinking BW-2-74-c for the previous meter Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of BW-2-74-d sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement BW-2-74-e and Labour . Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of BW-2-74-f sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement, BW-2-74-g and Labour etc. Clayey soil (11 m dia. Well ) BW-2-75-a Depth from bed level upto 3.0 M BW-2-75-b Beyond 3m upto 10m depth
Rmt Rmt
33910.00 40692.00
18
ITEM CODE
ITEM DESCRIPTION
UNIT
RATE
Beyond 10 m upto 20 m Add 5% for every additional meter depth of sinking over the rate of sinking BW-2-75-c for the previous meter BW-2-75-d Add for dewatering @ 5% of cost, if required. Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of BW-2-75-e sinking for the previous meter BW-2-75-f Add 5% of cost for dewatering on the cost, if required Add 25% of cost for Kentledge including supports, loading arrangement BW-2-75-g and Labour ). Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of BW-2-75-h sinking for the previous meter BW-2-75-i Add 5% of cost for dewatering, if required Add 20% of cost for Kentledge including supports, loading arrangement BW-2-75-j and Labour). Soft rock (11m dia well ) BW-2-76 Depth of soft rock strata upto 3m Hard rock (11m dia well ) BW-2-77 Depth of hard rock upto 3 m Sinking of 12 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Sandy soil BW-2-78-a I) Depth below bed level upto 3.0 M BW-2-78-b Beyond 3m upto 10m depth Beyond 10m upto 20m Add 5% for every additional meter depth of sinking over the rate of sinking BW-2-78-c for the previous meter Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of BW-2-78-d sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement BW-2-78-e and Labour . Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of BW-2-78-f sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement, BW-2-78-g and Labour etc. Clayey soil (12 m dia. Well ) BW-2-79-a Depth below bed level upto 3.0 M BW-2-79-b Beyond 3m upto 10m depth Beyond 10 m upto 20 m Add 5% for every additional meter depth of sinking over the rate of sinking BW-2-79-c for the previous meter BW-2-79-d Add for dewatering @ 5% of cost, if required. Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of BW-2-79-e sinking for the previous meter BW-2-79-f Add 5% of cost for dewatering on the cost, if required Add 25% of cost for Kentledge including supports, loading arrangement BW-2-79-g and Labour ). Beyond 30m upto 40 m
Rmt Rmt
95189.00 114226.00
19
ITEM CODE
BW-2-79-h BW-2-79-i BW-2-79-j BW-2-80 BW-2-81
ITEM DESCRIPTION
Add 10% for every additional meter depth of sinking over the rate of sinking for the previous meter Add 5% of cost for dewatering, if required Add 20% of cost for Kentledge including supports, loading arrangement and Labour). Soft rock (12m dia well ) Depth of soft rock strata upto 3m Hard rock (12m dia well ) Depth of hard rock strata upto 3 m Sinking of Twin D Type well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level.
UNIT
Rmt Rmt Rmt Rmt Rmt
RATE
342652.00 431742.00 411183.00 96500.00 125737.00
Sandy soil BW-2-82-a Depth from bed level upto 3.0 M BW-2-82-b Beyond 3m upto 10m depth Beyond 10m upto 20m Add 5% for every additional meter depth of sinking over the rate of sinking BW-2-82-c for the previous meter Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of BW-2-82-d sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement BW-2-82-e and Labour . Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of BW-2-82-f sinking for the previous meter Add 20% of cost for Kentledge including supports, loading arrangement, BW-2-82-g and Labour etc. Clayey soil (Twin D Type Well ) BW-2-83-a Depth below bed level upto 3.0 M BW-2-83-b Beyond 3m upto 10m depth Beyond 10 m upto 20 m Add 5% for every additional meter depth of sinking over the rate of sinking BW-2-83-c for the previous meter BW-2-83-d Add for dewatering @ 5% of cost, if required. Beyond 20m upto 30 m Add 7.5% for every additional meter depth of sinking over the rate of BW-2-83-e sinking for the previous meter BW-2-83-f Add 5% of cost for dewatering on the cost, if required Add 25% of cost for Kentledge including supports, loading arrangement BW-2-83-g and Labour ). Beyond 30m upto 40 m Add 10% for every additional meter depth of sinking over the rate of BW-2-83-h sinking for the previous meter BW-2-83-i Add 5% of cost for dewatering, if required Add 20% of cost for Kentledge including supports, loading arrangement BW-2-83-j and Labour). Soft rock (Twin D Type well ) BW-2-84 Depth of soft rock strata upto 3m Hard rock (Twin D Type well ) BW-2-85 Depth of hard rock strata upto 3 m
Rmt Rmt
20200.00 24241.00
20
ITEM CODE
ITEM DESCRIPTION
Pneumatic sinking of wells with equipment of approved design, drawing and specifications worked by competent and trained personnel and comprising of compression and decompression chambers, reducers, two air locks separately for men and plant & materials, arrangement for supply of fresh air to working chambers, check valves, exhaust valves, shafts made from steel plates of riveted construction not less than 6 mm thick to withstand an air pressure of 0.50 MPa, controlled blasting of hard rock where required, staircases and 1 m wide landing plate forms with railing, arrangement for compression and decompression, electric lighting of 50 V maximum, proper rooms for rest and medical examinations and compliance with safety precautions as per IS:4138, all as per clause1207.6 of Specifications.
UNIT
RATE
BW-2-86
Cum
95739.00
BW-2-87 BW-2-88
Sand filling in wells complete as per drawing and technical specifications Providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing Providing and placing in position controlled cement concrete in bottom plug of well foundations in wells or through tremie arrangement including compacting by vibrators and curing where necessary etc. complete as specified and directed. (10% extra cement to be added when concreting is done under water). PCC Grade M20 Using Concrete Mixer Using Batching Plant, Transit Mixer and Crane/concrete pump PCC Grade M25 Using Concrete Mixer Using Batching Plant, Transit Mixer and Crane/concrete pump PCC Grade M30 Using Concrete Mixer Using Batching Plant, Transit Mixer and Crane/concrete pump PCC Grade M35 Using Concrete Mixer Using Batching Plant, Transit Mixer and Crane/concrete pump Providing and placing in position controlled cement concrete in Intermediate plug of well foundations in wells or through tremie arrangement including compacting by vibrators and curing where necessary etc. complete as specified and directed Grade M20 PCC Using Concrete Mixer Using Batching Plant, Transit Mixer and Crane/concrete pump Grade M25 PCC Using Concrete Mixer Using Batching Plant, Transit Mixer and Crane/concrete pump Grade M30 PCC Using Concrete Mixer Using Batching Plant, Transit Mixer and Crane/concrete pump Providing and placing in position controlled cement concrete in top plug of well foundations including compacting by vibrators and curing etc. complete as specified and directed. Grade M15 PCC Using Concrete Mixer Grade M20 PCC Using Concrete Mixer
Cum MT
1766.00 76648.00
BW-2-96 BW-2-97
Cum Cum
5017.00 5394.00
21
ITEM CODE
ITEM DESCRIPTION
UNIT
Cum Cum Cum Cum
RATE
5775.00 5971.00 5817.00 6289.00
Grade M25 PCC BW-2-98-a Using Concrete Mixer BW-2-98-b Using Batching Plant, Transit Mixer and Crane/concrete pump Grade M30 PCC BW-2-99-a Using Concrete Mixer BW-2-99-b Using Batching Plant, Transit Mixer and Crane/concrete pump Providing and placing in position controlled cement concrete in Well cap RCC Grade M20 BW-2-100-a Using concrete Mixer BW-2-100-b Using Batching Plant, Transit Mixer and Concrete Pump RCC Grade M25 BW-2-101-a Using concrete Mixer BW-2-101-b Using Batching Plant, Transit Mixer and Concrete Pump Providing and placing in positon controlled cement concrete M-30 grade for RCC well cap with minimum cement content as 400 kg/cum. water cement ratio not exceeding 0.40 and maximum size of aggregate not exceeding 20 mm including necessary formwork to give form finish surface, compacting by vibrators and curing etc. complete as specified and directed. (Excluding reinforcement) RCC Grade M30 BW-2-102-a Using Concrete Mixer BW-2-102-b Using Batching Plant, Transit Mixer and Concrete Pump RCC Grade M35 BW-2-103-a Using Concrete Mixer BW-2-103-b Using Batching Plant, Transit Mixer and Concrete Pump RCC M40 Grade BW-2-104 Using Batching Plant, Transit Mixer and Concrete Pump Providing and fixing steel anchor dowel bars in open foundations including drilling holes 75 mm dia. in hard rock, providing and placing in position 32 mm dia. dowel bars 1.8m in hard rock and 1.8m above hard BW-2-105 rock, effectively grouting the holes with cement mortar of 1:1 proportion etc complete and specified as directed. (Grout shall be filled in the hole first and bars inserted and pressed in the drilled hole). Providing and fixing steel anchor dowel bars at the base of well foundations through bottom plug including drilling holes 75 mm dia in hard rock, providing and placing in positon dowel bars of 32 mm dia 1.8 m BW-2-105 in hard rock and 1.8 m above hard rock, effectively grouting the holes with cement mortar of 1: 1 proportion etc. complete as specified and directed. (grout shall be filled in the hole first and bars inserted and pressed in drilled hole.) Providing and laying colcrete for foundation of piers, abutments, wingwalls, retaining walls, anchor blocks, thrust blocks etc. for encasing of pipes in trenches etc. using cement sand colgrout of 1 :1.5 proportion by BW-2-106 weight and water cement ratio not exceeding 0.56 in required lines and levels including watertight formwork, curing etc. complete as specified and directed. (Excluding reinforcement) Supplying, fitting and placing un-coated HYSD bar reinforcement in BW-2-107 foundation complete as per drawing and technical specifications Supplying, fitting and placing un-coated Mild steel reinforcement complete BW-2-108 in foundation as per drawing and technical specification
No.
5556.00
No.
9696.00
No.
4149.00
MT MT
62100.00 61199.00
22
ITEM CODE
ITEM DESCRIPTION
Providing and placing in position controlled cement concrete of M-30 grade with minimum cement content of 400 kg/cum. and water cement ratio not exceeding 0.40 in base slab for subways to required lines and levels including surfaces to be roughen to receive the other finishes etc. complete as specified and directed. Providing and placing in position controlled cement concrete of M-35 grade with minimum cement content of 400 kg/cum. and water cement ratio not exceeding 0.40 in base slab for subways to required lines and levels including surfaces to be roughen to receive the other finishes etc. complete as specified and directed. Providing and placing in position controlled cement concrete of M-45 grade for foundation work with minimum cement 400 kg/cum and water cement ratio not exceeding 0.4 for RCC raft foundation slab with V notches sloped / flat / strip footings, pile caps, tie beams to required lines / levels including levelling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed but excluding reinforcement.(Using Batching Plant, Transit Mixer and Concrete Pump) Providing and placing in position controlled cement concrete of M-50 grade for foundation work with minimum cement 400 kg/cum and water cement ratio not exceeding 0.4 for RCC raft foundation slab with V notches sloped / flat / strip footings, pile caps, tie beams to required lines / levels including levelling, compacting by vibrators, curing including shuttering, centering as necessary and required etc. complete as specified and as directed but excluding reinforcement.(Using Batching Plant, Transit Mixer and Concrete Pump) Providing and installing in position controlled concrete of grade M-40 with minimum cement content as 400 kg/cum. and W.C ratio not exceeding 0.40 for R.C.C work in cast-in-situ bored piles each of load capacity as per design and of special diameter using maximum 20mm size of aggregate including boring through all strata except rock, including placing of concrete by tremie arrangement through mild steel casing to the required depth through all strata except rock, compaction as necessary with drawl of mild steel casing including chipping / dressing of piles to required levels, cleaning the reinforcement etc. complete as specified and directed (Excluding reinforcement) (Using Batching Plant, Transit Mixer and Concrete Pump)
UNIT
RATE
BW-2-108
Cum
6202.00
BW-2-109
Cum
6547.00
BW-2-110
Cum
7197.00
BW-2-111
Cum
7756.00
BW-2-112-a BW-2-112-b BW-2-112-c BW-2-112-d BW-2-112-e BW-2-112-f BW-2-112-g BW-2-112-h BW-2-112-i BW-2-112-j BW-2-112-k BW-2-112-l BW-2-112-m
1) 400mm dia 2) 450mm dia 3) 500mm dia 4) 550mm dia 5) 600mm dia 6) 650mm dia 7) 700mm dia 8) 750mm dia 9) 800mm dia 10) 900mm dia 11) 1000mm dia 12) 1100mm dia 13) 1200mm dia
Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt
1282.00 1622.00 2003.00 2423.00 2884.00 3385.00 3926.00 4506.00 5127.00 6489.00 8011.00 9694.00 11536.00
23
ITEM CODE
BW-2-113
ITEM DESCRIPTION
Providing and laying in position M-15 plain cement concrete to fill up loose pockets of foundations bed for making required levels, annular filling around abutments, piers, columns for foundation. Providing and installing in position controlled concrete of grade M-35 with minimum cement content as 400 kg/cum. and W.C ratio not exceeding 0.40 for R.C.C work in cast-in-situ bored piles with hydraulic boring machine including mobilization to the site of work. Each pile shall have load capacity as per design and of specific diameter using maximum 20mm size of aggregate including boring through all strata including rock, including placing of concrete by tremie arrangement through mild steel casing to the required depth. Compaction as necessary with drawl of mild steel casing including chipping / dressing of piles to required levels, cleaning the reinforcement etc. complete as specified and directed (Excluding reinforcement) (Using Batching Plant, Transit Mixer and Concrete Pump)
UNIT
Cum
RATE
5218.00
BW-2-114-a BW-2-114-b BW-2-114-c BW-2-114-d BW-2-114-e BW-2-114-f BW-2-114-g BW-2-114-h BW-2-114-i BW-2-114-j BW-2-114-k BW-2-114-l BW-2-114-m
1) 400mm dia 2) 450mm dia 3) 500mm dia 4) 550mm dia 5) 600mm dia 6) 650mm dia 7) 700mm dia 8) 750mm dia 9) 800mm dia 10) 900mm dia 11) 1000mm dia 12) 1100mm dia 13) 1200mm dia Providing and installing in position controlled concrete of grade M-40 with minimum cement content as 400 kg/cum. and W.C ratio not exceeding 0.40 for R.C.C work in cast-in-situ bored piles with hydraulic boring machine including mobilization to the site of work. Each pile shall have load capacity as per design and of specific diameter using maximum 20mm size of aggregate including boring through all strata including rock, including placing of concrete by tremie arrangement through mild steel casing to the required depth. Compaction as necessary with drawl of mild steel casing including chipping / dressing of piles to required levels, cleaning the reinforcement etc. complete as specified and directed (Excluding reinforcement) (Using Batching Plant, Transit Mixer and Concrete Pump)
Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt
2894.00 3129.00 3381.00 3678.00 3967.00 4256.00 5317.00 5711.00 6103.00 8390.00 9430.00 10470.00 12217.00
BW-2-115-a BW-2-115-b BW-2-115-c BW-2-115-d BW-2-115-e BW-2-115-f BW-2-115-g BW-2-115-h BW-2-115-i BW-2-115-j BW-2-115-k BW-2-115-l BW-2-115-m
1) 400mm dia 2) 450mm dia 3) 500mm dia 4) 550mm dia 5) 600mm dia 6) 650mm dia 7) 700mm dia 8) 750mm dia 9) 800mm dia 10) 900mm dia 11) 1000mm dia 12) 1100mm dia 13) 1200mm dia
Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt Rmt
2931.00 3176.00 3438.00 3748.00 4050.00 4351.00 5430.00 5841.00 6250.00 8576.00 9661.00 10747.00 12550.00
24
ITEM DESCRIPTION
UNIT
RATE
BW-3-5
BW-3-6
Brick masonry work in 1:3 in sub-structure complete excluding pointing and plastering, as per drawing and technical specifications Pointing with cement mortar (1:3 ) on brick work in substructure as per Technical specifications Plastering with cement mortar (1:3 ) on brick work in sub-structure as per Technical specifications Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and Technical Specifications Random Rubble Masonry Coursed rubble masonry (first sort ) Ashlar masonry ( first sort ) Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications PCC Grade M15 Height upto 5m Providing and laying cement concrete in abutment and piers, head walls for culverts, using max aggregate size of 40mm minimum cement content of 310Kg and max water cement ratio of 0.45 including shuttering and scaffolding complete as specified and directed. the rate including providing 100 dia AC weep holes at 1.5m c/c vertical and horizontal above ground level wherever required( The abutment and piers shall be cast for only 1.0m height at a time) PCC Grade M20 Height upto 5m PCC Grade M25 Height upto 5m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height 5m to 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height above 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump PCC Grade M30 Height upto 5m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height 5m to 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height above 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Providing and placing in position not more than 1.5m height at one time controlled cement concrete M-30 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work in abutmens, retaining walls with form finished surface as perdrg. in required line and level including levelling, compacting by vibrators, curing including formwork including providing and forming 100 dia AC weep holes at 1.5m c/c vertically and horizontally in a staggered fashion above ground level as necessary etc. complete as specified and directed.
Cum
5519.00
Cum
5933.00
BW-3-9
Cum
6852.00
25
ITEM CODE
ITEM DESCRIPTION
Providing and placing in position not more than 1.5m height at one time controlled cement concrete M-35 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work in abutmens, retaining walls with form finished surface as per drawing in required line and level including levelling, compacting by vibrators, curing including formwork including providing and forming 100 dia AC weep holes at 1.5m c/c vertically and horizontally in a staggered fashion above ground level as necessary etc. complete as specified and directed. Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications Providing and Placing in position controlled cement concrete for substructure work with minimum cement content of 400 kg/cum and water cement ratio not exceeding 0.40 for columns pier shafts, abutments, walls of subways retaining walls to required lines as necessary etc. complete as directed. RCC Grade M20 Height upto 5m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height 5m to 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height above 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump RCC Grade M25 Height upto 5m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height 5m to 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height above 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump RCC Grade M30 Height upto 5m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height 5m to 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height above 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump RCC Grade M35 Height upto 5m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Height 5m to 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump
UNIT
RATE
BW-3-10
Cum
7197.00
BW-3-11
Each
278.00
26
ITEM CODE
BW-3-15-e BW-3-15-f
ITEM DESCRIPTION
Height above 10m Using concrete Mixer With Batching Plant, Transit Mixer and Concrete Pump Providing and placing in position controlled cement concrete M-30 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work in coping on retaining walls, bed blocks, abutment / pier / column caps, dirtwalls, pedestals for bearing on piers / abutments as per drawings and designs including projections, moulding, champhers etc. of required shape and size including levelling, compacting by vibrators, curing, finishing the exposed surfaces including formwork, shuttering and centering as necessary and required etc. complete as specified and directed but excluding reinforcement. Providing and placing in position controlled cement concrete M-35 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work in coping on retaining walls, bed blocks, abutment / pier / column caps, dirtwalls, pedestals for bearing on piers / abutments as per drawings and designs including projections, moulding, champhers etc. of required shape and size including levelling, compacting by vibrators, curing, finishing the exposed surfaces including formwork, shuttering and centering as necessary and required etc. complete as specified and directed but excluding reinforcement.
UNIT
Cum Cum
RATE
6895.00 7561.00
BW-3-16
Cum
6678.00
BW-3-17
Cum
6796.00
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications Supplying, fitting and placing Mild steel reinforcement complete in subBW-3-19 structure as per drawing and technical specification Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification BW-3-20-a Granular material BW-3-20-b Sandy material Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller BW-3-21 size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification. BW-3-18
MT MT
62235.00 60414.00
Cum Cum
826.00 1930.00
Cum
1109.00
BEARINGS
Note: The bearings shall be duly got tested and certified by an approved agency to the satisfaction of the Engineer. Testing may be carried out during the manufacturing and/or before their installation as may be directed by the Engineer. All charges or expences incurred in this respect shall be born by the contractor. the bearing shall be fixed perfectly in horizontal position. Supplying, fitting and fixing in position true to line and level sliding plate bearing with PTFE surface sliding on stainless steel complete including all MT accessories as per drawing and Technical Specifications and BS: 5400, capacity section 9.1 & 9.2 (for PTFE) and clause 2004 of MoRTH Specifications.
BW-3-22
378.00
27
ITEM CODE
ITEM DESCRIPTION
UNIT
RATE
BW-3-23
BW-3-24
BW-3-25
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre MT assembly to be of cast steel/fabricated structural steel, metal and capacity elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications. Supplying, fitting and fixing in position true to line and level sliding plate bearing with stainless steel plate sliding on stainless steel plate with mild MT steel matrix complete including all accessories as per drawing and capacity Technical Specifications. Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of Cucm MoRTH specifications complete including all accessories as per drawing and Technical Specifications. Providing and placing in position not more than 1.5m height at one time controlled cement concrete M-40 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work in abutmens, retaining walls with form finished surface as per drawing in required line and level including levelling, compacting by vibrators, curing including formwork including providing and forming 100 dia AC weep holes at 1.5m c/c vertically and horizontally in a staggered fashion above ground level as necessary etc. complete as specified and directed.(Using Batching Plant, Transit Mixer and Concrete Pump) Providing and placing in position controlled cement concrete M-40 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work in coping on retaining walls, bed blocks, abutment / pier / column caps, dirtwalls, pedestals for bearing on piers / abutments as per drawings and designs including projections, moulding, champhers etc. of required shape and size including levelling, compacting by vibrators, curing, finishing the exposed surfaces including formwork, shuttering and centering as necessary and required etc. complete as specified and directed but excluding reinforcement. Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications. Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
259.00
365.00
1.00
BW-3-26
Cum
7834.00
BW-3-27
Cum
7494.00
BW-3-28
MT
143.00
BW-3-29
MT
143.00
28
ITEM CODE
ITEM DESCRIPTION
Providing and placing in position controlled cement concrete, max water cement ratio of 0.40 for RCC work of main beams, girders, cross girders, diaphragm solid slab to required lines and levels including levelling, compacting by vibrators, curing including formwork with formfinish surface as necessary and required centering etc.complete as specified and directed but excluding reinforcement. RCC Grade M20 Using Concrete Mixer For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m Height 5m to 10m Height above 10m For T-beam & slab, 25-35% of (a+b+c) Height upto 5m Height 5m to 10m Height above 10m Using Batching Plant, Transit Mixer and Concrete Pump For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m Height 5m to 10m Height above 10m For T-beam & slab, 25-35% of (a+b+c) Height upto 5m Height 5m to 10m Height above 10m RCC Grade M25 Using Concrete Mixer For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m Height 5m to 10m Height above 10m For T-beam & slab, 25-35% of (a+b+c) Height upto 5m Height 5m to 10m Height above 10m Using Batching Plant, Transit Mixer and Concrete Pump For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m Height 5m to 10m Height above 10m For T-beam & slab, 25-35% of (a+b+c) Height upto 5m Height 5m to 10m Height above 10m Providing and placing in position controlled cement concrete of M-30 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work of main beams, girders, cross girders, diaphragm solid slab to required lines and levels including levelling, compacting by vibrators, curing including formwork with formfinish surface as necessary and required centering etc.complete as specified and directed but excluding reinforcement.(using concrete mixer). RCC Grade M 30 Using Concrete Mixer
UNIT
RATE
29
ITEM CODE
BW-4-9-a BW-4-9-b BW-4-9-c BW-4-10-a BW-4-10-b BW-4-10-c
ITEM DESCRIPTION
For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m Height 5m to 10m Height above 10m For T-beam & slab, 25-35% of (a+b+c) Height upto 5m Height 5m to 10m Height above 10m Providing and placing in position controlled cement concrete of M-35 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work of main beams, girders, cross girders, diaphragm solid slab to required lines and levels including levelling, compacting by vibrators, curing including formwork with formfinish surface as necessary and required centering etc.complete as specified and directed but excluding reinforcement.(using concrete mixer).
UNIT
Cum Cum Cum Cum Cum Cum
RATE
7005.00 7297.00 7589.00 7297.00 7589.00 7881.00
RCC/PSC Grade M35 Using concrete mixer. For solid slab super-structure, 18-28% of (a+b+c) BW-4-11-a Height upto 5m BW-4-11-b Height 5m to 10m BW-4-11-c Height above 10m For T-beam & slab, 23-33% of (a+b+c) BW-4-12-a Height upto 5m BW-4-12-b Height 5m to 10m BW-4-12-c Height above 10m For box girder and balanced cantilever, 38-58% of cost of concrete. BW-4-13-a Height upto 5m BW-4-13-b Height 5m to 10m BW-4-13-c Height above 10m Providing and placing in position controlled cement concrete of M-40 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work of main beams, girders, cross girders, diaphragm solid slab to required lines and levels including levelling, compacting by vibrators, curing including formwork with formfinish surface as necessary and required centering etc.complete as specified and directed but excluding reinforcement.(using concrete mixer). PSC Grade M-40 Using concrete mixer. For solid slab super-structure, 20-30% of (a+b+c) BW-4-14-a Height upto 5m BW-4-14-b Height 5m to 10m BW-4-14-c Height above 10m For T-beam & slab, 25-35% of (a+b+c) BW-4-15-a Height upto 5m BW-4-15-b Height 5m to 10m BW-4-15-c Height above 10m
30
ITEM CODE
ITEM DESCRIPTION
Providing and placing in position controlled cement concrete of M-30 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work of main beams, girders, cross girders, diaphragm solid slab to required lines and levels including levelling, compacting by vibrators, curing including formwork with formfinish surface as necessary and required centering etc.complete as specified and directed but excluding reinforcement.(using batch mixing plant).
UNIT
RATE
RCC Grade M 30 Using Batching Plant, Transit Mixer and Concrete Pump. For solid slab super-structure, 20-30% of (a+b+c) BW-4-16-a Height upto 5m BW-4-16-b Height 5m to 10m BW-4-16-c Height above 10m For T-beam & slab, 25-35% of (a+b+c) BW-4-17-a Height upto 5m BW-4-17-b Height 5m to 10m BW-4-17-c Height above 10m Providing and placing in position controlled cement concrete of M-35 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work of main beams, girders, cross girders, diaphragm solid slab to required lines and levels including levelling, compacting by vibrators, curing including formwork with formfinish surface as necessary and required centering etc.complete as specified and directed but excluding reinforcement.(using batch mixing plant). RCC/PSC Grade M35 Using Batching Plant, Transit Mixer and Concrete Pump For solid slab super-structure, 18-28% of (a+b+c) BW-4-18-a Height upto 5m BW-4-18-b Height 5m to 10m BW-4-18-c Height above 10m For T-beam & slab, 23-33% of (a+b+c) BW-4-19-a Height upto 5m BW-4-19-b Height 5m to 10m BW-4-19-c Height above 10m For box girder and balanced cantilever, 38-58% of cost of concrete. BW-4-20-a Height upto 5m BW-4-20-b Height 5m to 10m BW-4-20-c Height above 10m Providing and placing in position controlled cement concrete of M-40 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC work of main beams, girders, cross girders, diaphragm solid slab to required lines and levels including levelling, compacting by vibrators, curing including formwork with formfinish surface as necessary and required centering etc.complete as specified and directed but excluding reinforcement.(using batch mixing plant). Grade M-40 Using Batching Plant, Transit Mixer and Concrete Pump For solid slab super-structure, 18-28% of (a+b+c) BW-4-21-a Height upto 5m BW-4-21-b Height 5m to 10m BW-4-21-c Height above 10m
31
ITEM CODE
ITEM DESCRIPTION
UNIT
Cum Cum Cum
RATE
8379.00 8720.00 9061.00
For T-beam & slab, 23-33% of (a+b+c) BW-4-22-a Height upto 5m BW-4-22-b Height 5m to 10m BW-4-22-c Height above 10m For box girder and balanced cantilever, 38-58% of cost of concrete. BW-4-23-a Height upto 5m BW-4-23-b Height 5m to 10m BW-4-23-c Height above 10m Providing and placing in position controlled cement concrete of M-30 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 in cast-in-situ RCC Kerbs in line and level and shape as per drawings, finishing the exposed faces including levelling, compacting by vibrators, curing including formwork, shuttering as necessary and required centering etc.complete as specified and directed Providing and placing in position controlled cement concrete of M-30 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 in RCC Approach Slab over / Beyond abutments as per drawings and designs, including levelling, compacting by vibrators, curing including formwork etc. complete as specified and directed but excluding reinforcement. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Providing and placing in position controlled cement concrete of M-35 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 in RCC Approach Slab over / Beyond abutments as per drawings and designs, including levelling, compacting by vibrators, curing including formwork etc. complete as specified and directed but excluding reinforcement. Providing and placing in position controlled cement concrete of M-30 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for cast-in-situ portions after launching girders of RCC Deck Slab, cross diaphragms to required lines and levels including levelling, compacting by vibrators, curing including formwork, temporary supports as necessary and required etc.complete as specified and directed but excluding reinforcement.(using batch mixing plant). M 30 Grade Using Batching Plant, Transit Mixer and Concrete Pump. For solid slab super-structure, 20-30% of (a+b+c) BW-4-29-a Height upto 5m BW-4-29-b Height 5m to 10m BW-4-29-c Height above 10m For T-beam & slab, 25-35% of (a+b+c) BW-4-30-a Height upto 5m BW-4-30-b Height 5m to 10m BW-4-30-c Height above 10m
BW-4-25
Cum
6980.00
BW-4-26
Cum
6108.00
BW-4-27
Cum
6241.00
BW-4-28
Cum
6241.00
32
ITEM CODE
ITEM DESCRIPTION
Providing and placing in position controlled cement concrete of M-35 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for cast-in-situ portions after launching girders of RCC Deck Slab, cross diaphragms to required lines and levels including levelling, compacting by vibrators, curing including formwork, temporary supports as necessary and required etc.complete as specified and directed but excluding reinforcement.(Using Batching Plant, Transit Mixer and Concrete Pump).
UNIT
RATE
RCC/PSC Grade M35 Using Batching Plant, Transit Mixer and Concrete Pump For solid slab super-structure, 18-28% of (a+b+c) BW-4-31-a Height upto 5m BW-4-31-b Height 5m to 10m BW-4-31-c Height above 10m For T-beam & slab, 23-33% of (a+b+c) BW-4-32-a Height upto 5m BW-4-32-b Height 5m to 10m BW-4-32-c Height above 10m For box girder and balanced cantilever, 38-58% of cost of concrete. BW-4-33-a Height upto 5m BW-4-33-b Height 5m to 10m BW-4-33-c Height above 10m Providing and placing in position controlled cement concrete of M-40 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for cast-in-situ portions after launching girders of RCC Deck Slab, cross diaphragms to required lines and levels including levelling, compacting by vibrators, curing including formwork, temporary supports as necessary and required etc.complete as specified and directed but excluding reinforcement.(using batch mixing plant). PSC Grade M-40 Using Batching Plant, Transit Mixer and Concrete Pump For solid slab super-structure, 18-28% of (a+b+c) BW-4-34-a Height upto 5m BW-4-34-b Height 5m to 10m BW-4-34-c Height above 10m For T-beam & slab, 23-33% of (a+b+c) BW-4-35-a Height upto 5m BW-4-35-b Height 5m to 10m BW-4-35-c Height above 10m For box girder and balanced cantilever, 38-58% of cost of concrete. BW-4-36-a Height upto 5m BW-4-36-b Height 5m to 10m BW-4-36-c Height above 10m
33
ITEM CODE
ITEM DESCRIPTION
UNIT
RATE
Providing and placing in position controlled cement concrete of M-35 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC Precast Girders and Diaphragms with form finish surface in any shape and size as per detailed drawings and designs including formwork, temporary supports as necessary and required, compacting by vibrators, levelling, curing and finishing etc.complete as specified and directed but excluding reinforcement and placing in position.(using concrete mixer). RCC/PSC Grade M35 Using concrete mixer. For solid slab super-structure, 18-28% of (a+b+c) BW-4-37-a Height upto 5m BW-4-37-b Height 5m to 10m BW-4-37-c Height above 10m For T-beam & slab, 23-33% of (a+b+c) BW-4-38-a Height upto 5m BW-4-38-b Height 5m to 10m BW-4-38-c Height above 10m For box girder and balanced cantilever, 38-58% of cost of concrete. BW-4-39-a Height upto 5m BW-4-39-b Height 5m to 10m BW-4-39-c Height above 10m Providing and placing in position controlled cement concrete of M-40 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC Precast Girders and Diaphragms with form finish surface in any shape and size as per detailed drawings and designs including formwork, temporary supports as necessary and required, compacting by vibrators, levelling, curing and finishing etc.complete as specified and directed but excluding reinforcement and placing in position.(using concrete mixer). PSC Grade M-40 Using concrete mixer. For solid slab super-structure, 20-30% of (a+b+c) BW-4-40-a Height upto 5m BW-4-40-b Height 5m to 10m BW-4-40-c Height above 10m For T-beam & slab, 25-35% of (a+b+c) BW-4-41-a Height upto 5m BW-4-41-b Height 5m to 10m BW-4-41-c Height above 10m Providing and placing in position controlled cement concrete of M-40 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for Prestressed Concrete Girders as per detailed drawings and designs having form finish surfaces including formwork on casting bed and temporary supports as necessary and required, compacting by vibrators, levelling, curing and finishing etc.complete as specified and directed including launching the girders in position using plant and equipment and providing erecting and removing the temporary staging as necessary and required etc. complete as specified and directed excluding reinforcement and placing in position.(using concrete mixer). PSC Grade M-40 Using concrete mixer. For T-beam & slab, 25-35% of (a+b+c)
34
ITEM CODE
BW-4-42-a Height upto 5m BW-4-42-b Height 5m to 10m BW-4-42-c Height above 10m
ITEM DESCRIPTION
UNIT
Cum Cum Cum
RATE
8730.00 9363.00 9995.00
Providing and placing in position controlled cement concrete of M-45 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for Prestressed Concrete Girders as per detailed drawings and designs having form finish surfaces including formwork on casting bed and temporary supports as necessary and required, compacting by vibrators, levelling, curing and finishing etc.complete as specified and directed including launching the girders in position using plant and equipment and providing erecting and removing the temporary staging as necessary and required etc. complete as specified and directed excluding reinforcement and placing in position.(using concrete mixer). PSC Grade M-45 For I-beam & slab including launching of precast girders by launching truss upto 40 m span, 21-31% of cost of concrete. BW-4-43-a Height upto 5m BW-4-43-b Height 5m to 10m BW-4-43-c Height above 10m For cast-in-situ box girder, segmental construction and balanced cantilever, 36-56% of cost of concrete. BW-4-44-a Height upto 5m BW-4-44-b Height 5m to 10m BW-4-44-c Height above 10m Providing and placing in position controlled cement concrete of M-40 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for Prestressed Concrete Girders as per detailed drawings and designs having form finish surfaces including formwork on casting bed and temporary supports as necessary and required, compacting by vibrators, levelling, curing and finishing etc.complete as specified and directed including launching the girders in position using plant and equipment and providing erecting and removing the temporary staging as necessary and required etc. complete as specified and directed excluding reinforcement and placing in position.(Using Batching Plant, Transit Mixer and Concrete Pump). M-40 Grade Using Batching Plant, Transit Mixer and Concrete Pump For solid slab super-structure, 18-28% of (a+b+c) BW-4-45-a Height upto 5m BW-4-45-b Height 5m to 10m BW-4-45-c Height above 10m For T-beam & slab, 23-33% of (a+b+c) BW-4-46-a Height upto 5m BW-4-46-b Height 5m to 10m BW-4-46-c Height above 10m For box girder and balanced cantilever, 38-58% of cost of concrete. BW-4-47-a Height upto 5m BW-4-47-b Height 5m to 10m BW-4-47-c Height above 10m Cum Cum Cum 9401.00 10083.00 10764.00
35
ITEM CODE
ITEM DESCRIPTION
Providing and placing in position controlled cement concrete of M-45 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for Prestressed Concrete Girders as per detailed drawings and designs having form finish surfaces including formwork on casting bed and temporary supports as necessary and required, compacting by vibrators, levelling, curing and finishing etc.complete as specified and directed including launching the girders in position using plant and equipment and providing erecting and removing the temporary staging as necessary and required etc. complete as specified and directed excluding reinforcement and placing in position.(Using Batching Plant, Transit Mixer and Concrete Pump).
UNIT
RATE
PSC Grade M-45 For solid slab/voided slab super-structure, 16-26% of cost of concrete (a+b+c) BW-4-48-a Height upto 5m BW-4-48-b Height 5m to 10m BW-4-48-c Height above 10m For I-beam & slab including launching of precast girders by launching truss upto 40 m span, 21-31% of cost of concrete. BW-4-49-a Height upto 5m BW-4-49-b Height 5m to 10m BW-4-49-c Height above 10m For cast-in-situ box girder, segmental construction and balanced cantilever, 36-56% of cost of concrete. BW-4-50-a Height upto 5m BW-4-50-b Height 5m to 10m BW-4-50-c Height above 10m
BARRIER
REINFORCEMENT,
BW-4-51
BW-4-52
Reinforced Cement Concrete Crash Barrier Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-20 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with premoulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified Type - A, "W" : Metal Beam Crash Barrier Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 Type - B, "THRIE" : Metal Beam Crash Barrier
Rmt
3446.00
Rmt
2841.00
36
ITEM CODE
ITEM DESCRIPTION
Providing and erecting a "Thrie" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a space of channel section 150 x 75 x 5 mm, 546 mm long complete as per clause 810 Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications Providing and placing in position controlled cement concrete of M-40 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 in RCC Approach Slab over / Beyond abutments as per drawings and designs, including levelling, compacting by vibrators, curing including formwork etc. complete as specified and directed but excluding reinforcement. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification
UNIT
RATE
BW-4-53
Rmt
3359.00
BW-4-54 BW-4-55
MT MT
63413.00 193785.00
BW-4-56
Cum
6813.00
BW-4-57 BW-4-58
Cum Cum
9879.00 5017.00
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification Providing and placing in position controlled cement concrete of M-45 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC Precast Girders and Diaphragms with form finish surface in any shape and size as per detailed drawings and designs including formwork, temporary supports as necessary and required, compacting by vibrators, levelling, curing and finishing etc.complete as specified and directed but excluding reinforcement and placing in position.(using concrete mixer). RCC Grade M-45 For solid slab/voided slab super-structure, 16-26% of cost of concrete (a+b+c) BW-4-59-a Height upto 5m BW-4-59-b Height 5m to 10m BW-4-59-c Height above 10m For I-beam & slab including launching of precast girders by launching truss upto 40 m span, 21-31% of cost of concrete. BW-4-60-a Height upto 5m BW-4-60-b Height 5m to 10m BW-4-60-c Height above 10m For cast-in-situ box girder, segmental construction and balanced cantilever, 36-56% of cost of concrete. BW-4-61-a Height upto 5m BW-4-61-b Height 5m to 10m BW-4-61-c Height above 10m Providing and placing in position controlled cement concrete of M-50 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for RCC Precast Girders and Diaphragms with form finish surface in any shape and size as per detailed drawings and designs including formwork, temporary supports as necessary and required, compacting by vibrators, levelling, curing and finishing etc.complete as specified and directed but excluding reinforcement and placing in position.(using concrete mixer).
37
ITEM CODE
ITEM DESCRIPTION
UNIT
RATE
RCC Grade M-50 For cast-in-situ box girder, segmental construction and balanced cantilever, 35-55% of cost of concrete BW-4-62-a Height upto 5m BW-4-62-b Height 5m to 10m BW-4-62-c Height above 10m Providing and placing in position controlled cement concrete of M-50 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for Prestressed Concrete Girders as per detailed drawings and designs having form finish surfaces including formwork on casting bed and temporary supports as necessary and required, compacting by vibrators, levelling, curing and finishing etc.complete as specified and directed including launching the girders in position using plant and equipment and providing erecting and removing the temporary staging as necessary and required etc. complete as specified and directed excluding reinforcement and placing in position.(using batch mixing plant). PSC Grade M-50 For cast-in-situ box girder, segmental construction and balanced cantilever, 35-55% of cost of concrete BW-4-63-a Height upto 5m BW-4-63-b Height 5m to 10m BW-4-63-c Height above 10m Providing and placing in position controlled cement concrete of M-45 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for cast-in-situ portions after launching girders of RCC Deck Slab, cross diaphragms to required lines and levels including levelling, compacting by vibrators, curing including formwork, temporary supports as necessary and required etc.complete as specified and directed but excluding reinforcement.(using batch mixing plant). PSC Grade M-45 For solid slab/voided slab super-structure, 16-26% of cost of concrete (a+b+c) BW-4-64-a Height upto 5m BW-4-64-b Height 5m to 10m BW-4-64-c Height above 10m For I-beam & slab including launching of precast girders by launching truss upto 40 m span, 21-31% of cost of concrete. BW-4-65-a Height upto 5m BW-4-65-b Height 5m to 10m BW-4-65-c Height above 10m For cast-in-situ box girder, segmental construction and balanced cantilever, 36-56% of cost of concrete. BW-4-66-a Height upto 5m BW-4-66-b Height 5m to 10m BW-4-66-c Height above 10m
38
ITEM CODE
ITEM DESCRIPTION
Providing and placing in position controlled cement concrete of M-50 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for cast-in-situ portions after launching girders of RCC Deck Slab, cross diaphragms to required lines and levels including levelling, compacting by vibrators, curing including formwork, temporary supports as necessary and required etc.complete as specified and directed but excluding reinforcement.(Using Batching Plant, Transit Mixer and Concrete Pump).
UNIT
RATE
PSC Grade M-50 For cast-in-situ box girder, segmental construction and balanced cantilever, 35-55% of cost of concrete BW-4-67-a Height upto 5m BW-4-67-b Height 5m to 10m BW-4-67-c Height above 10m Providing and placing in position controlled cement concrete of M-55 grade using minimum cement content as 400Kg/cum and max water cement ratio of 0.40 for cast-in-situ portions after launching girders of RCC Deck Slab, cross diaphragms to required lines and levels including levelling, compacting by vibrators, curing including formwork, temporary supports as necessary and required etc.complete as specified and directed but excluding reinforcement.(Using Batching Plant, Transit Mixer and Concrete Pump). For cast-in-situ box girder, segmental construction and balanced cantilever, 35-55% of cost of concrete BW-4-68-a Height upto 5m BW-4-68-b Height 5m to 10m BW-4-68-c Height above 10m BW-4-69 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications Precast - pretensioned Girders (Providing, precasting, transportation and placing in position precast pretensioned concrete girders as per drawing and technical specifications) Providing and fixing Helical pipes in voided concrete slabs Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. )
BW-5-1-b
Rmt
3672.00
BW-5-1-c
Rmt
2705.00
39
ITEM CODE
BW-5-1-d
ITEM DESCRIPTION
Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight providing and fixing elastomeric slab seal expansion joint with maximum horizontal movement upto 50 mm complete as per approved drawings and specificaitons to be installed by manufacturer / supplier ensuring compliance to the manufacturer's instructions for installation etc. complete and as directed. Elastomeric Slab Steel Expansion Joint (Providing and laying of an elastomeric slab steel expansion joint, catering to right or skew (less than 20 deg., moderately curved with maximum horizontal movement upto 50 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation and clause 2606 of MoRTH specifications for road & bridge works.) Providing and fixing in position expansion joints in footpath consisting of Shalitex board, thermocol packing and polysulphide sealant as per detailed drawings etc. complete as specified an directed. providing and fixing strip seal type expansion joint catering to +40 mm size expansion as per drawing and specifications including alloy extended edge beams, fixing by welding etc. complete as specified and directed.(To be installed by manufacturer / suplier ensuring compliances to manufacturer's instructions) Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.) Drainage Spouts complete as per drawing and Technical specification Burried Joint (Providing and laying a burried expansion joint, expansion gap being 20 mm, covered with 12 mm thick, 200 mm wide galvanised wieldable structural steel plate as per IS: 2062, placed symmetrical to centre line of the joint, resting freely over the top surface of the deck concrete, welding of 8 mm dia. 100 mm long galvanised nails spaced 300 mm c/c along the centre line of the plate, all as specified in clause 2604.) Asphaltic Plug joint (Providing and laying of asphaltic plug joint to provide for horizontal movement of 25 mm and vertical movement of 2 mm, depth of joint varying from 75 mm to 100 mm, width varying from 500 mm to 750 mm (in traffic direction), covered with a closure plate of 200mm x 6mm of wieldable structural steel conforming to IS: 2062, asphaltic plug to consist of polymer modified bitumen binder, carefully selected single size aggregate of 12.5 mm nominal size and a heat resistant foam caulking/backer rod, all as per approved drawings and specifications.)
UNIT
Rmt
RATE
173.00
BW-5-1-e
Rmt
219.00
BW-5-1-f
Rmt
25.00
BW-5-1-g
Rmt
13336.00
BW-5-1-h
Rmt
1067.00
BW-5-1-i
Rmt
12663.00
BW-5-1-j
Each
1869.00
BW-5-1-k
Rmt
1444.00
BW-5-1-l
Rmt
1071.00
40
ITEM CODE
ITEM DESCRIPTION
Compression Seal Joint (Providing and laying of compression seal joint consisting of steel armoured nosing at two edges of the joint gap suitably anchored to the deck concrete and a preformed chloroprene elastomer or closed cell foam joint sealer compressed and fixed into the joint gap with special adhesive binder to cater for a horizontal movement upto 40 mm and vertical movement of 3 mm.) Modular Strip / Box Seal Joint (Providing and laying of a modular strip Box steel expansion joint including anchorage catering to a horizontal movement beyond 70 mm and upto 140mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.) Modular Strip / Box Seal Joint (Providing and laying of a modular strip box seal expansion joint catering to a horizontal movement beyond 140mm and upto 210mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.)
UNIT
RATE
BW-5-1-m
Rmt
3504.00
BW-5-1-n
Rmt
9222.00
BW-5-1-o
Rmt
9234.00
BW-5-2-a
Sqm
258.00
BW-5-2-b
Sqm
804.00
BW-5-2-c
Sqm
643.00
BW-5-2-d
Sqm
1272.00
BW-5-3-b
Sqm
287.00
41
ITEM CODE
ITEM DESCRIPTION
Providing and applying epoxy base paint to RCC piers, columns, beams, girders, diaphragms, slabs, parapets etc. including cleaning the surfaces thoroughly so as to remove deposited salts, oil, grease, tar, moisture etc. from the surface, preparing the surface, applying putty consisting of epoxy base paint and steolite powder, to render the concrete surfaces smooth by covering small irregularities and applying one coat of epoxy paint including scaffolding etc. complete as specified and directed.(2 coats epoxy + primer) Providind and appling epoxy seal coat to new or repaired surfaces of RCC structural members, prepared by mixing araldite GY 250 and hardener in 100:50 proportion by weight with stiff nylon bristle brush as per manufacturer's specifications etc. complete as specified ands directed. Providing and applyinf two coats of Hi-Build coal tar epoxy formulation corroseal TE-321 with an interval of minimum 4 hours - 8 hours between application of successive coats including preparing and cleaning the surface thoroughly so as to remove deposited salts, grease, oil, dust, tar etc. using coarse brush etc. complete as specified and directed. Providing and applying protective paint consisting of two coats of coat tar epoxy paint over one coat of primer of approved quality and make to the external surfaces of concrete structures to be buried under the soil etc. complete as specified and directed.
UNIT
RATE
BW-5-3-c
Sqm
366.00
BW-5-3-d
Sqm
185.00
BW-5-3-e
Sqm
274.00
BW-5-3-f
Sqm
300.00
BW-5-4-b
497.00
BW-5-4-c
2323.00
BW-5-4-d
1590.00
(V) MISCELLANEOUS REPAIR ITEMS - REMOVING WEARING COAT, STAGING, EPOXY MORTAR
Removing the old heavy duty mastic asphalt wearing coat/asphaltic wearing coat laid over the expansion joints by chiselling, picking or by any other means as necessary and required so as to expose the joint completely including disposing off the debris etc. complete as specified and directed. Providing and erecting scaffolding/ staging upto a height of 10m including all cross bracings to make it strong and sturdy etc. complete as specified as directed.
BW-5-5-a
Sqm
89.00
BW-5-5-b
Sqm
157.00
42
ITEM CODE
ITEM DESCRIPTION
Providing and applying epoxy mortar for repairs to cracked portions of RCC columns, piers, beams, girders, diaphragms, slabs, parapets etc. including chipping the loose cracked concrete, cleaning the surface and removing the rust thoroughly and completely by means of wire brushes, sand blasting and washing with water etc. rebuilding the section by first applying one coat of epoxy primer coat of araldite / GY 257 and hardener HY840 in 100:50 proportion by weight, applying epoxy mortar prepared by mixing araldite, hardener and quartzite sand in 100:50:900 proportion by weight in required shape and architectural finishes, if any, finishing the surface smooth including applying a seal coat of araldite and hardener in 100:50 proportion by weight with stiff nylon bristle brush etc. complete as specified as directed.
UNIT
RATE
BW-5-5-c
Kg
262.00
BW-5-6-a BW-5-6-b
No. No.
350000.00 27400.00
BW-5-6-k BW-5-6-l
No. No.
45000.00 25000.00
43
ITEM CODE
ITEM DESCRIPTION
Carrying out Cyclic load test at 1.50 times the design load or as specified on vertical test pile of 1000mm dia. as per the procedure laid down in IS:2911 including maintaining and submitting complete records of load settlement as specified and directed.
UNIT
RATE
BW-5-6-p
No.
750000.00
(VIII) OTHER ITEMS (Cleaning, Polymer painting, Integrity test, pier protection, CPCC, Dressing Joints, Compression seal, Thermoplastic paint, stainless steel railing, roof structure and roofing, cement paint, polymer mortar)
Cleaning the concrete surfaces of bridge with detergent and other cleaning materials as necessary including removing all dust, grease, stains etc. to render the surface clean including removing all traces of cleaning materials with jet of clean water etc. complete as specified and directed. Providing grease in grease box of bearing including removing the old grease from the box, cleaning the box etc.as specified and directed. Providing and applying elastic, polymeric membrane forming system with anti carbonation and breathing properties of approved make of water based acrylic polimers with selected mineral fillers having properties of ultra violet resistant, carbonation resistant breathable, water proofing coating and applying one coat of primer and two top coats of approved shade and colour including cleaning and preparing the surface as requred including scaffolding and all labour etc. complete as directed. Carrying out integrity test on piles of various diameters as per standard procedure and submitting reports. Providing and casting in C.C. M-25 for pier protection as per detailed drawing complete as specified and directed. Providing and applying CPCC anticorrosive treatment as per the Indian patent No. 481/DEL93. Dated 13/05/93 and Indian patent No. 258/DEL/92, Dated 25/03/92 to Mild and HYSD bar reinforcement cut and bent to the required length, shape and size including chemical, labours, transportation of steel bars for treatment and bringing back the same for fixing in position with all accessories and material required for giving the treatment etc. complete as specified and directed.
BW-5-7-a
Sqm
30.00
BW-5-7-b
Kg
271.00
BW-5-7-c
Sqm
234.00
BW-5-7-d BW-5-7-e
No. Rmt
500.00 3563.00
BW-5-7-f
MT
7525.03
44
ITEM CODE
ITEM DESCRIPTION
Dressing of joints between the existing mastic panels with hot rubberized sealing compound confirming to I.S. 1834-1984 after proper cleaning with compressed air applying required primer and providing layer of lime powder over hot sealing compound etc. completed as specified and directed. (Sealing of 25 mm wide joints between the mastic panels with average depth of 12 mm.) Providing and laying of compression seal expansion joint consisting of steel armoured nosing at two edges of the joint gap suitably anchored to the deck concrete and a preformed chloroprene elastomer or closed cell foam joint sealer compressed and fixed into the joint gap with special adhesive binder to cater for a horizontal movement upto 40 mm and vertical movement of 3 mm. Providing and applying hot applied thermoplastic road marking material with glass beads extremely high skid resistance 2.5 mm thick without primer coat (Tack coat) on Asphalt road surface. All labour, materials, with special aggregates as specified in B.S. part - l & ll 1989 and carrying out the marking on any road in center line and other marking continious or intermitten 10cm. or 15cm width also pedestrians crossing strips as well as spraying further quantity of glass beads of type ll uniformly into a mono layer on to the hot paint line in quick succession of the paint spraying opration @ 250gms per sqm. area as directed and as per BS / MOST specifications in white / yellow colour.
UNIT
RATE
BW-5-7-g
Rmt
28.00
BW-5-7-h
Rmt
8046.00
a) White colour b) Yellow colour Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification Providing and fixing stainless steel railing with stainless steel post of 5mm thick S.S. post shaped as shown in the drawing and fixing 25mm dia S.S. pipe in the precut holes in the post and 75mm dia s.s. pipe handrail fixed at top with 3mm plate welded to s.s. post including handrail fixed at top with 3mm plate welded to s.s. post including proper cutting welding anchoring fixing of post to the treads of staircase, required machinery labour etc. complete as specified and directed. Providing and fibricating in position support structure for roofing in s.s. pipes of 75/100 mm and other diameters as per approved structural design fixed to base slab with necessary base plates, cleats, fixtures, fasteners, hardware etc. complete as specified and directed. Removing the existing rolled steel joist beams, stanchions etc. completely and staking the material at ward office or at site as directed by Engineer. Removing existing advertising boards completely and stacking as directed by Engineer. Providing and fixing colour coated galvanised colour bond base having tensile strength (Min. 550 Mpa) C.R. steel base metal with hot dip alloy coating of AL-ZN-SI as per ASTM - A - 792 M- 02 / AS 1397 ALU Zinc alloy crimp sheets with flashing for girth 0 to 600 mm with standard length of 2440 mm and flashing for girth 601 to 1200 mm as directed by Engineerin-charge. Providing and fixing flashing for advertisement for girth 600 mm to 1200 mm with standard length as per detailed drawing and manufacturing specification and as directed by Engineer-in-charge.
BW-5-7-l
Rmt
2803.00
BW-5-7-m
Rmt
1417.00
BW-5-7-n BW-5-7-o
MT Sqm
3342.00 92.00
BW-5-7-p
Sqm
1058.00
BW-5-7-q
Rmt
746.00
45
ITEM CODE
ITEM DESCRIPTION
Providing and applying approved quality water proof cement paint to structure with one coat of primer and two coats of cement paint including watering, brooming, curing complete as specified and directed. Providing and laying polymer modified mortar in the proportion of 1:5:15 ( 1 Polymer, 5 Cement, 15 Quartz sand) for replacement of spalled concrete, plaster, repairing cracks in the structure etc. complete as specified and directed. a) 10 mm thick average b) 25 mm thick average Providing & placing in position controlled concrete M-35 grade with minimum cement content as 400 kg/cum and water cement ratio not exceeding 0.40 for R.C.C Precast Box Drain in suitable handling units with form finished surface in any shape & size as per detailed drawings and designs including formwork, temporary supports if required, compacting by vibrators, leveling, curing and finishing etc. complete as specified and including precasting, transportation & erection in place asdirected but excluding reinforcement (using RMC) Providing & Laying inverted filter behind Abutment & RE wall with suitable thickness. P & P erecting in place precast RE wall panels in M35 complete with precast facia and GI/HDPE reinforcement. Panel shall be given approved cement paint from outside & 2 coats of coal for epoxy from inside. Panel shall be cast and stored away from the site as per manufacturers design and as per MORTH specifications. P & F Arc type Anticrash Barrier as per drawing Drilling holes in existing foundation for anchoring 6mm to 32mm dia rods pf RCC jacket with non shrink free flow grout. Cost to include drilling for 1m depth, grout etc. except reinforcement. Providing and placing 600 thk Diaphragm wall in M30 concrete with reinforcement to enable excavation of new footing etc. cost to include mobilisation equipment, drilling excluding reinforcement. Providing and placing in position Soil Anchors upto 6m length 15t capacity by drilling through diaphragm wall etc. Cost to include drilling grouting with cementitious material etc. complete excluding reinforcement. Providing Fusion Bonded Epoxy Coating (FBEC) to reinforcing steel bars as per IS 13620: 1993 specifications for a coating thickness of 175 microns ( with permissible variation of 50 microns) including testing at plant etc. complete as per specifications.
UNIT
RATE
Refer Common Schedule Refer Common Schedule
BW-5-7-r
Cum
11501.00
BW-5-7-s
Cum
787.00
BW-5-7-t
Sqm
3795.00
BW-5-7-u BW-5-7-v
Rmt No.
7482.00 1710.00
BW-5-7-w
Sqm
10015.00
BW-5-7-x
No.
9186.00
BW-5-7-y
MT
13365.00
BW-6-1
Cum
1017.00
BW-6-2
Cum
1491.00
BW-6-3
Cum
5322.00
46
ITEM CODE
ITEM DESCRIPTION
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications
UNIT
RATE
BW-6-7
Stone/Boulder Cement Concrete blocks of size 0.3x0.3 x0.3 m cast in cement concrete of Grade M15 Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Geotextile Filter (Laying of a geotextile filter between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching.) Toe protection (A toe wall for toe protection can either be in dry rubble masonry in case of dry rubble pitching or pitching with stones in wire crates or it can be in PCC M15 nominal mix if cement concrete block have been used for pitching . Rates for toe wall can be adopted from respective clauses depending upon approved design. The rate for excavation for foundation, dry rubble masonry and PCC M15 have been analysed and given in respective chapters.) Providing and laying Flooring complete as per drawing and Technical specifications laid over cement concrete bedding. Rubble stone laid in cement mortar 1:3 Cement Concrete blocks Grade M15 Dry rubble Flooring Curtain wall complete as per drawing and Technical specification
Sqm
3148.00
BW-6-10
BW-6-11
Stone masonry in cement mortar (1:3) Cement concrete Grade M15 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Gabian Structure for Retaining Earth (Providing and construction of a gabain structure for retaining earth with segments of wire crates of size 7 m x 3 m x 0.6 m each divided into 1.5 m compartments by cross netting, made from 4 mm galvanised steel wire @ 32 kg per 10 sqm having minimum tensile strength of 300 Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven into mesh with double twist, mesh size not exceeding 100 x 100 mm, filled with boulders with least dimension of 200 mm, all loose ends to be tied with 4 mm galvanised steel wire) Gabian Structure for Erosion Control, River Training Works and Protection works (Providing and constructing gabain structures for erosion control, river training works and protection works with wire crates of size 2 m x 1 m x 0.3 m each divided into 1m compartments by cross netting, made from 4 mm galvanised steel wire @ 32 kg per 10 sqm having minimum tensile strength of 300 Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven into mesh with double twist, mesh size not exceeding 100 mm x 100 mm, filled with boulders with least dimension of 200 mm, all loose ends to be securely tied with 4 mm galvanised steel wire.)
Cum
1530.00
Cum
2489.00
47
ITEM CODE
ITEM DESCRIPTION
Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000m(Thickness 75 mm) Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Guniting concrete surface with cement mortar applied with compressor after cleaning surface and spraying with epoxy complete as per Technical specification Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy Sealing of cracks/porous concrete by injection process through nipples/Grouting complete as per Technical specification. Cement Grout Cement mortar (1:1) Grouting Patching of damaged concrete surface with polymer concrete and curing compounds, initiator and promoter, available in present formulations, to be applied as per instructions of manufacturer and as approved by the Engineer. Sealing of crack / porous concrete with Epoxy Grout by injection through nipples complete as per clause 2803.1. Applying epoxy mortar over leached, honey combed and spalled concrete surface and exposed steel reinforcement complete as per Technical specification Removal of defective concrete, cleaning the surface thoroughly, applying the shotcrete mixture mechanically with compressed air under pressure, comprising of cement, sand, coarse aggregates, water and quick setting compound in the proportion as per clause 2807.1., sand and coarse aggregates conforming to IS: 383 and table 1 of IS: 9012 respectively, water cement ratio ranging from 0.35 to 0.50, density of gunite not less than 2000 kg/cum, strength not less than 25 Mpa and workmanship conforming to clause 2807.6. Applying pre-packed cement based polymer mortar of strength 45 Mpa at 28 days for replacement of spalled concrete Eproxy bonding of new concrete to old concrete Providing external prestressing with high tensile steel wires/strands including drilling for passage of prestessing steel, all accessories for stressing and stressing operation and grouting complete as per drawing and Technical specification Providing external prestressing with high tensile steel wires/strands including drilling for passage of prestessing steel, all accessories for stressing and stressing operation and grouting complete as per drawing and Technical specification Providing external prestressing with high tensile steel wires/strands including drilling for passage of prestessing steel, all accessories for stressing and stressing operation and grouting complete as per drawing and Technical specification Replacement of bearings complete as per Technical specification Rectification of bearings as per Technical specifications Replacement of Expansion Joints complete as per drawings Replacement of damaged concrete railing. Replacement of crash barrier. Replacement of damaged mild steel railing
UNIT
RATE
BW-7-1
Sqm
88.00
BW-7-2
Sqm
65.00
BW-7-3
Sqm
1945.00
BW-7-4
Each
168.00
Kg Kg Sqm
BW-7-7 BW-7-8
Kg Sqm
2246.00 327.00
BW-7-9
Sqm
337.00
Sqm Sqm MT
BW-7-13
MT
342261.00
48
ITEM CODE
ITEM DESCRIPTION
Repair of crash barrier (Repair of concrete crash barrier with cement concrete of M-30 grade by cutting and trimming the damaged portion to a regular shape, cleaning the area to be repaired thoroughly, applying cement concrete after erection of proper form work.) Repair of RCC Railing (Carrying out repair of RCC M30 railing to bring it to the original shape.) Repair of steel Railing (Repair of steel railing to bring it to the original shape)
UNIT
RATE
BW-7-21
Rmt
263.00
BW-7-22 BW-7-23
Rmt Rmt
172.00 266.00
49
Code
LB-02 LB-04 LB-05 LB-06 LB-07 LB-08 LB-09 LB-12 LB-13 LB-15 LB-17 LB-20 LB-21 LB-22 LB-24 LB-25 LB-28 LB-27 LB-32 LB-33 LB-40 LB-41 Welder
Description of Labour
Mazdoor/Dresser/Sinker (Skilled) Bhisti Blacksmith (Ist class) Blacksmith (IInd class) Driller (Jumper) Carpenter 2nd class Mazdoor Operator (grouting) Diver Fitter Mali Mason (Ist class) Mason (IInd class) Mechanic Blaster (Stone cutter) Painter Ist class Painter semi skilled Beldar/Dresser (Semi Skilled)/Oil Man Mate / Supervisor Medical Officer Para medical personnel
Unit
Day Day Day Day Day Day Day Day Day Day Day Day Day Day Day Day Day Day Day Day Day Day
Rate
425.00 450.00 300.00 400.00 325.00 400.00 375.00 300.00 350.00 450.00 425.00 350.00 500.00 400.00 500.00 400.00 450.00 325.00 350.00 550.00 1,200.00 600.00
Code
HC-02 HC-09 HC-13 HC-15 HC-17 HC-22 HC-23 HC-27 HC-28
Description of Machine
Dewatering Pump of 5HP Hydraulic Excavator of 1 cum bucket Tipper - 5 cum Truck Trailor 30 tonne capacity Front End loader 1 cum bucket capacity Plate compactor Welding machine Tractor Air Compressor
Unit
Day Hr Hr Hr Hr Hr Day Hr Hr
Rate
770.00 1,375.00 475.00 1,210.00 687.50 50.00 1,250.00 185.63 337.50
50
51
Code
MA-GN-01 MA-GN-04 MA-GN-05 MA-GN-06 MA-GN-07 MA-GN-08 MA-GN-09 MA-GN-10 MA-GN-11 MA-GN-14 MA-GN-15 MA-GN-16 Cement
Description
Unit
MT Cum Cum Cum Cum Cum Cum Cum Each Cum Cum Cum
Rate
6000 1200 3000 850 850 820 650 600 13 420 385.00 385
Artificial crushed sand (Coarse sand at Site) Plaster Sand (Fine sand at Site) Stone Aggregate (Metal I) : 6-12 mm nominal size (Aggregates 10 mm nominal size) Stone Aggregate (Metal II) : 20-32 mm nominal size (Aggregates 20 mm nominal size) Stone Aggregate (Metal III) : 40 mm nominal size (Aggregates 40 mm nominal size) Rubble For Masonary Rubble For Soling Through and bond stone Stone Boulder of size 150 mm and below at Cruser Plant Boulder with minimum size of 300 mm for Pitching at Site Gravel/Quarry spall at Site
52
38
MA-BW-028
No.
10,560.00
39
MA-BW-029
No.
30,250.00
40
MA-BW-030
No.
55,000.00
41 42 43
No. No. Kg
53
54
79
MA-BW-076
Rmt
7,976.65
80
MA-BW-077
Rmt
7,976.65
81 82 83 84 85 86
87
MA-BW-084
Rmt
756.25
88 89 90 91 92 93 94 95 96 97 98 99
MA-BW-085 MA-BW-086 MA-BW-087 MA-BW-089 MA-BW-090 MA-BW-092 MA-BW-093 MA-BW-095 MA-BW-096 MA-BW-098 MA-BW-099
1,039.50 253.00 41.00 5.50 165.00 69.00 10,450.00 165.00 2,475.00 89.00 15,400.00 3,250.00
55
MA-BLD-PN-11 Oil paint/ synthetic enamel paint MA-BW-138 MA-BW-139 MA-BW-140 MA-BW-141 MA-BW-142 MA-BW-143 CPCC anticorrosive treatment as per the Indian platent No. 481/DEL93. Chloroprene seal (Expansion joint) Theromoplastic paint Glass beads Stainless steel pipe 25mm Top rail pipe 75mm
56
57
Appendix-B APPENDIX-B
Page 1
Appendix-B APPENDIX-B
Sr. No. 19 20 21 22 23 24 26 27 28 29 30 31 32 33 34 35 36 37 38 39
Category Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work
Sub Category Veneer Laminate Pre-laminated particle board-Exterior grade Gypsum board. Cement Bonded Board Shower partitions Mineral Fiber Ceiling Calcium silicate false ceiling Wax Polish Block Board / Ply Cement Board PVB/ Laminate Film Door Hardware Door Lock & Handle Door closer Door Locks (Concealed / Surface mounted) Locks Door Seal Wool pile Weather Strip Door Handle (Concealed / Surface Metalic Steel Fire Door
Brand Name Duro, Green, Donear, Century Greenlam, Century, Merino Novopan/ Merino / Anchorlam/ Bhutan Board Saint Gobain, Lafarge BISON by NCL Dorma, Grohe, Hindware Lloyd, Nittobo,Armstrong. Hilux, Promat Mansion Phenol bonded boards of Merino/ Duro/ Samrat/ Kit Ply Smart Board, JAMES Hardie Dupont Ingersolrand, Geze, Dorma, Guardian,Dorset, Magnum, Union, Kitch Ingersolrand, Geze, Dorma Guardian, DLine Ingersolrand, Geze, Dorma , Guardian Ingersolrand / Dorma,Haffle,Dorset Dorset, Sobeet, Godrej Enviro Seal, Anand Raddiplex Ingersolrand , Geze, Dorma, Alu Alpha Naviar,Shakti Met,Promat , Godrej ,Adhunik,Basic Arch Products, Radiant, Signum
Page 2
Appendix-B APPENDIX-B
Sr. No. 40 41 42 43 44 45
Category Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work Wood & PVC Work
Sub Category Fire smoke Seal Fire Rated Hardware Non Metalic Fire Door Metallic Door Metallic Window Stainless Steel Screws for fabrication and fixing of windows Two or Four Point locking Openable Window Handle Butt Hinges openable Window shutters Mild Steel Butt Hinges/ Piano Hinges Nuts Bolts /Screws Concealed Tower Bolt Patch Fitting Double Side Tab, Decoretive Tab UPVC Joinery Acoustic Insulation Glass Clear Float Glass Source for tempering Refl. Glass /Clear Glass (Toughened)
Brand Name Hilti, CFS, SPWB Joints Spray Ingersolrand, Gaze, Dorma Naviar / Promat, Signum Shakti Met / Promat, Signum Shakti Met Kundan/ Puja/ Atul
46 47 48 49 50 51 52 53 54 55 56 57 58 59
Gize, Alu Alpha Haffle, Alu Alpha Jolly, Garg,AMIT, ASI Supreme Kundan/ Puja/ Atul Ingersolrand, Alu Alpha Ingersolrand, Dorma, Geze 3M Fenesta, Veka, Euro plast, Aluplast, Amon Ra U.P. Twiga Ltd, Lloyd, Saint Gobain, Ecophone Saint Gobain, AIS ,Asahi, Pilkington, Modi, Guardian Glass AIS Glass/ Saint Gobain/ Modiguard GSC Toughened / Gold Plus/ Gurind/ Art n Glass/ Impact Safety Saint Gobain/ Modi Float/ Asahi Float
Page 3
Appendix-B APPENDIX-B
Sr. No. 60 61 62 63 64 65 66 67 68 69
Category Flooring work Flooring work Flooring work Flooring work Flooring work Flooring work Flooring work Flooring work Flooring work Flooring work
Sub Category Vitrified Ceramic Tiles Precast mosaic & P.C. Tiles Industrial Tile Glazed Ceramic Tiles Timber flooring False Floor Perquet Floor Floor Springs Rubber Tile Flooring Granamex Tiles Interlocking Concrete Blocks Gypsum Plaster White washing lime Paint/primer/oil bound distemper Acrylic paint Water proof cement paint Fire Retardant paint Mirror Anti Corrosive Bitumastic Paint Epoxy Paint
Brand Name Diamontile , Marbo Granit, Granamite,Boss,NITCO, Asian, RAK, Euro, Somany, Bell Ceramic, Kajaria NITCO/ MODERN Endura Orient, Kajaria, Nitco, Somany,Bell, Johnson, Asian, RAK, Euro, Par-Ky, Ego flooring, Beutex Hewetson, Unifloor, Unitile Nemo / Prima/ Pergo Ingersolrand /Dorma/ GEZE Ecoflex Surfaces Pvt. Ltd., Rudi Sports Surfaces, The Floorsmiths Vyara Tiles Pvt. Ltd.. Super Decorative Floorings Pvt. Ltd., Sai Enterprises Vyara Tiles Pvt. Ltd.. Super Decorative Floorings Pvt. Ltd., Sai Enterprises,Hindustan Tiles, Nimco Prefab,R.K. Tiles. St. Gobain, Permaboard, Vinayak gypsum Dehradun (Source) Asian Paints, ICI, Nerolac,Dulux,Spectrum,Unitile ,Berger,Aero paints,Jotun Snowcem India Ltd ,Asian Paints, Berger,Nitco Cem Jotun, Hilti, Akzonobel Modi Guard, Saint Gobain Asian/Burger/J&N Asian / Berger / J&N
70
Flooring work
72 73 74 75 76 77 78 79
Finishing Works Finishing Works Finishing Works Finishing Works Finishing Works Finishing Works Finishing Works Finishing Works
Page 4
Appendix-B APPENDIX-B
Category Finishing Works Finishing Works Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware
Brand Name
Vitreous China Sanitaryware Concealed Flushing Cisterns European water closet Sensor Operated Flushing System Seat covers (Heavy Duty) Flat Back Urinal (Sensor Operated Urinal Wash basin SEMI-RECESSED BASIN Bath Tub Bath Tub Mixer Telephonic Shower C.P fittings & Bathroom accessories Geayser Health Faucet Soap Dispensar Flow Regulator Devices Stainless Steel Sink
CERA,ROCA,HINDWARE CERA,ROCA,HINDWARE Parry ware , Hindware , Cera CERA,ROCA,PARRYWARE Parry ware , Hindware , Cera CERA,ROCA,PARRYWARE Parry ware , Hindware , Cera HINDWARE,PARRYWARE,JHONSON TOPAZ HINDWARE,DURAVIT,RAKNOVA KOHLER,PARRYWARE,HINDWARE KOHLER,JAQUAR,HINDWARE PARRYWARE,JAQUAR,HINDWARE Jaquar , Parry ware , Hindware,ROCA,Cera Racold, venus wave,AO smith jaquar JAQUAR,KOHLER,SCHELL,PARRYWARE ,ESS JAQUAR,ROCA,CERA ARCO Nirali , Franke , Parry ware , Cera,JAYNA,AMC,NEELKANTH
Page 5
Appendix-B APPENDIX-B
Sr. No. 101 102 103 104 105 106 107 108 109 110 111 112 113
Category Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware
Sub Category C.P Bottle Trap Sink mixer with regular swinging spout Basin mixer Waste coupling C.P. Grating CP / SS Grating for Floor Trap & Floor Drain Stainless Steel (304) Square Frame Grating Strainer C.I Strainer more than 65mm dia. Cast Brass Clean Out Plugs Concealed stop cock Shower arm,rose Bath spout with wall flange 4way diverter concealed fitting, withbuilt in nonreturn valves and diverter handle Double coat hook Towel Rack (600mm) Towel Ring Toilet Paper Holder Grab Bar Urinal Push Cock
Brand Name JAQUAR,ROCA,KOHLER,PARRYWARE,E SS JAQUAR,ESS,GROHE Jaquar,Hindware,ESS Jaquar,Hindware,PARRYWARE GMGR , Chilly , Viking NEER,ACO,VIJAY Noway,Chilly,Camry RB , Intervalve , Zoloto , VB LEADER,KARTAR,SANT GMGR,Neer, Viking Jaquar , Hindware , ESS Jaquar , Hindware , ESS Jaquar , Parry ware , Hindware
114
Sanitary ware
Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware
Page 6
Appendix-B APPENDIX-B
Sr. No. 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139
Category Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware
Sub Category ANGLE COCK Piller COCK Soap Dish Two way Bib cock C.P Angle Valve Ball Valve GM Peet Valve GM Wheel Valve Pressure Reducing Valves Butterfly valves Float valve (C.I) Gate valve G.M. Non return valve C.I. Non return valve Flap Type Check Valve Solenoid Valve Automatic Air vent Stoneware pipes/Gully traps SWR Pipe & Fittings type B ( for internal drainage) SWR Pipe & Fittings type A ( for Rain water upto 160mm dia)
Brand Name JAQUAR,HINDWARE,PARRYWARE JAQUAR,ESS,AMERICAN STANDARDCELLA JAQUAR,HIDWARE,PARRYWARE JAQUAR,ESS,PARRYWARE JAQUAR,ROCA,KOHLER RB , Intervalve , Zoloto , VB,ARCO,SANT,KARTAR RB , Intervalve , Zoloto , VB RB , Intervalve , Zoloto , VB Hawa , Kirloskar , Sant , VB, zoloto, RB RB , Intervalve , Zoloto , VB, KSB, KARTAR, SKS, Delval, Audco, Intervalve LEADER,SARKAR Zoloto,neta,leader RB , Intervalve , Zoloto , VB RB , Intervalve , Zoloto , VB hawa , Intervalve , Audco Rotex , Asco , Switzer , Intervalve Hawa , RB, Zoloto Rajora , Equivalent supreme, finolex, prince
140
Sanitary ware
Page 7
Appendix-B APPENDIX-B
Sr. No. 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161
Category Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware
Sub Category UPVC pipes/fittings UPVC ASTM pipes CPVC Pipes and Fittings Copper Pipes G.I. Pipes / M.S. Pipe G.I. fittings (malleable cast iron) C.I. fittings C.I pipe & Fittings Sand Cast Iron Pipes & fittings HDPE pipes For Internal Drainage RCC NP2 Class Pipe PVC KHURRA Pressure Guage RCC Grating Electronic Flow Meter Water Level Controller Water Level Indicator Grating K.K.Manhole C.I manhole cover & framing Water Meter R.C.C Pipe
Brand Name Supreme , Finolex , Prince,JAIN PIPES SUPREME,SURYA ROSHNI,FINOLEX Astral, Ajay, Ashirwad flow guard pipes,supreme,Prince Rajco, Maxflow Tata , Jindal , Zenith,SURYA ROSHNI Unik , R Brand , Zoloto M , Unco,KS NEEL,KARTAR,SARKAR NECO,SKF NECO,RIF,HEPCO SUPREME,JAIN PIPES,EONN PLAST Indian Hume pipe, AA Srinivasa pipe industries SUPREME,prince,FINOLEX H. Guru / Forbes Marshall / Waaree,wika,fiberg Pratibha / Alcock Rockwin / Aquamate Technica / Waaree Technica / Waaree Jain spun pipe / Pragati neco, bengal iron corporation Kay Cee / Kent / Desmesh Jain Spun Pipe / Pragati /Daya Spun Pipe
Page 8
Appendix-B APPENDIX-B
Category Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Sanitary ware Aluminum Work
Sub Category Pipe Supports Insulation Solar System Storage Type Hot Water Heater Pre-Fabricated Structural supports and clamps pumps
Brand Name Hangers Intello Tech / GMGR / Chilly Thermaflex / Armaflex / Kiflex TATA BP/Racold/Jain solar/Sudarshan Venus / Bajaj / Racold CHILLY,EASYFLEX,CAMRY Grundfos,ITT,DP
168
Aluminum Work
169
Aluminum Work
Aluminium Systems/ Anodized aluminum fittings for doors/windows Aluminium Cleat arrangement for Glazings / Cur. Wall size Aluminium Sections E.P.D.M. Gaskets Water proofing compound Membrane Waterproofing system Chemical Waterproofing system Water stops Garden Benches Granite Benches Versicell Mat
Indal,Hindalco,Bhoruka,Midi,Royal Touch,Alufit(Sapa),Kawneer,Schueco,Reyn aers ,Crown, ALANS, Classic/,Bharat,Argent Samples to be got approved by Engineerin charge. Hindalco/ Jindal/ Mahavir/ lndal Anand/ Roop/Bohra/Hanu CICO, Pidilite, Laticrete BASF, STP limited, Texsa, W R Grace BASF, MC-Bauchemie, Sika, Sunanda Specialty Coatings, Perma Construction Aid Pvt. Ltd. Hydrotite, BASF, Hydroswell Saflow Products Pvt. Ltd., Kanha Import Export Pvt. Ltd., Shardha Metalic Jayantilal & Co., Jayant Minerals Pvt. Ltd., Ambaji Stones Dcor Pvt. Ltd. ZTC International Landscape Solutions Pvt. Ltd., Hesda Solutions, Matrix Solutions
Aluminum Work Aluminum Work Water Proofing Water Proofing Water Proofing Water Proofing Landscaping & Irrigation Landscaping & Irrigation Landscaping & Irrigation
Page 9
Appendix-B APPENDIX-B
Sr. No. 179 180 181 182 183 184 185 186
Category Landscaping & Irrigation Landscaping & Irrigation Ready Mix Concrete Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous
Sub Category PVC Perforated Pipes Play equipments Ready Mix Concrete Structural Sealant Polysulphide sealant Bitumen Impregnated Board Polyethylene back up rod Epoxy False Ceiling Members(Perimeter, ceiling section, intermediates, angles etc.) Welding rod MS black enameled/galvanized ERW conduits Toilet Cubical Metal Deck Sheet Shear Stud/Connector Clamp,Rebar,Chemcial fastner Anchor Fasteners / bolts Masking Tapes Dash Fasteners Stainless Steel Bolts, Washers and Nuts
Brand Name Rex Polyextrusion Ltd., Akash Enterprises, Zenplas Pipes Pvt. Ltd. Koochie, Playworld Systems ACC, RMC, Ultra tech Wacker, Dow Corning, GE Pidilite, Chemetall-Rai Shalitex Supreme Ind. Ltd. Fosroc/ STP/ CICO/ Ardex
187
Miscellaneous
188 189 190 191 192 193 194 195 196 197
Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous
ADVANI AKG, BEC, Steelkraft Merino TATA/SAIL KOCO Hilti,Fischer,Wurth Hilti, Fischer, Halfen 3M, Sun Control/ Wonder Polymer SS grade, Hilti/ Kundan/ Puja/ Atul
Page 10
Appendix-B APPENDIX-B
Sr. No. 198 199 200 201 202 203 204 205 206 207 208 209
Category Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous Miscellaneous
Sub Category Stainless Steel Pressure Plate Screws Stainless Steel Friction Stay Weather Silicon make and grade Structural Silicon Backer Road GRC Jali Tensile fabric System Stainless Steel Polycarbonate Sheet Post tensioning system PT strands Adhesives & Grouts
Brand Name Kundan/ Puja/ Atul Hetish, Haffle, Securistyle Dow Corning/ Momentive (GE) Dow Corning/ Momentive (GE) Supreme Industries Ltd Terrafirma, Ecovision & Mahesh GRC Ferrari, Mehler, MakMax Jindal/ SAIL/ Golden Danpalon,Alcox, Polygal,V. A. Corporation, Joy Fab, Yadav Engineering VSL, Utracon, BBR DP Wires, Tata, Usha Martin Bal, Laticrete, KeraKoll, Pidilite
Page 11