1 Input data
Anchor type and diameter: Effective embedment depth: Material: Evaluation Service Report: Issued I Valid: Proof: Stand-off installation: Anchor plate: Profile: Base material: Reinforcement: ETA 98/0001 08.05.2013 | 20.02.2018 design method Extended ETAG (No. 001 Annex C/2010) without clamping (anchor); restraint level (anchor plate): 2,00; eb = 10 mm; t = 8 mm Hilti Grout: , multipurpose, fc,Grout = 30,00 N/mm2 lx x ly x t = 300 mm x 300 mm x 8 mm; (Recommended plate thickness: not calculated) Pipe; (L x W x T) = 168 mm x 168 mm x 9 mm cracked concrete, C20/25, fcc = 25,00 N/mm2; h = 140 mm no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm) no longitudinal edge reinforcement Reinforcement to control splitting according to ETAG 001, Annex C, 5.2.2.6 present. Geometry [mm] & Loading [kN, kNm] HST M12 hef = 70 mm, hnom = 80 mm

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.com Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:

Profis Anchor 2.4.6


2 19.03.2014

2 Load case/Resulting anchor forces


Load case: Design loads Anchor reactions [kN] Tension force: (+Tension, -Compression) Tension force Shear force Shear force x Anchor 1 0,000 1,237 0,875 2 0,005 1,237 0,875 3 0,005 1,237 0,875 4 0,000 1,237 0,875 max. concrete compressive strain: 0,03 [] max. concrete compressive stress: 0,76 [N/mm2] resulting tension force in (x/y)=(62/-63): 0,010 [kN] resulting compression force in (x/y)=(-50/49): 21,010 [kN] 4 y

Shear force y 0,875 0,875 0,875 0,875

Compression 1 x 3

Tension

3 Tension load (ETAG, Annex C, Section 5.2.2)


Steel Strength* Pullout Strength* Concrete Breakout Strength** Splitting failure** * anchor having the highest loading 3.1 Steel Strength NRk,s [kN] 45,000 3.2 Pullout Strength NRk,p [kN] 12,000 yc 1,000 gM,p 1,500 NRd,p [kN] 8,000 NSd [kN] 0,005 gM,s 1,500 NRd,s [kN] 30,000 NSd [kN] 0,005 Load [kN] 0,005 0,005 0,010 N/A **anchor group (anchors in tension) Capacity [kN] 30,000 8,000 25,809 N/A Utilization bN [%] 1 1 1 N/A Status OK OK OK N/A

3.3 Concrete Breakout Strength Ac,N [mm2] 80975 ec1,N [mm] 0 N0 Rk,c [kN] 21,084
2 A0 c,N [mm ] 44100

ccr,N [mm] 105 ec2,N [mm] 0 NRd,c [kN] 25,809

scr,N [mm] 210 yec2,N 1,000 NSd [kN] 0,010 ys,N 1,000 yre,N 1,000 k1 7,200

yec1,N 1,000 gM,c 1,500

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.com Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:

Profis Anchor 2.4.6


3 19.03.2014

4 Shear load (ETAG, Annex C, Section 5.2.3)


Steel Strength (without lever arm)* Steel failure (with lever arm)* Pryout Strength** Concrete edge failure in direction ** * anchor having the highest loading 4.1 Steel failure (with lever arm) l [mm] 20 NSd / NRd,s 0,000 aM 2,00 1 - NSd / NRd,s 1,000 M0 Rk [kNm] 0,105 gMs,b,V 1,250 MRk,s = M0 Rk,s (1 - NSd/NRd,s) [kNm] 0,105 VM Rd,s [kN] 8,399 VSd [kN] 1,237 Load [kN] N/A 1,237 4,950 N/A **anchor group (relevant anchors) Capacity [kN] N/A 8,399 102,936 N/A Utilization bV [%] N/A 15 5 N/A Status N/A OK OK N/A

VM Rk,s = aM * MRk,s / l [kN] 10,498 4.2 Pryout Strength Ac,N [mm2] 147500 ec1,V [mm] 0 gM,c,p 1,500
2 A0 c,N [mm ] 44100

ccr,N [mm] 105 ec2,V [mm] 0 VSd [kN] 4,950

scr,N [mm] 210 yec2,N 0,998

k-factor 2,200 ys,N 1,000 yre,N 1,000 N0 Rk,c [kN] 21,084

yec1,N 0,998 VRd,c1 [kN] 102,936

5 Combined tension and shear loads (ETAG, Annex C, Section 5.2.4)


bN 0,001 bN + bV <= 1
a a

bV 0,147

a 1,500

Utilization bN,V [%] 6

Status OK

6 Displacements (highest loaded anchor)


Short term loading: NSk VSk = = 0,004 [kN] 0,917 [kN] dN dV dNV Long term loading: NSk VSk = = 0,004 [kN] 0,917 [kN] dN dV dNV = = = 0,001 [mm] 0,252 [mm] 0,252 [mm] = = = 0,000 [mm] 0,170 [mm] 0,170 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not included in this calculation! The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.com Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:

Profis Anchor 2.4.6


4 19.03.2014

7 Warnings
To avoid failure of the anchor plate the required thickness can be calculated in PROFIS Anchor. Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the loading! Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software considers that the grout is installed under the anchor plate without creating air voids and before application of the loads. The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C! The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be followed to ensure a proper installation.

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.com Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:

Profis Anchor 2.4.6


5 19.03.2014

8 Installation data
Anchor plate, steel: Anchor type and diameter: HST, M12 Profile: Pipe; 168 x 168 x 9 mm Installation torque: 0,060 kNm Hole diameter in the fixture: df = 14 mm Hole diameter in the base material: 12 mm Plate thickness (input): 8 mm Hole depth in the base material: 95 mm Recommended plate thickness: not calculated Minimum thickness of the base material: 140 mm Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.

8.1 Required accessories Drilling Suitable Rotary Hammer Properly sized drill bit Cleaning Manual blow-out pump y Setting Torque wrench Hammer

150

150

25 1 3 125 150

125 2 25 25 125 125 25 Coordinates Anchor [mm] Anchor 1 2 3 4 x -125 0 125 0 y 0 -125 0 125 c-x c+x c-y c+y Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

150

www.hilti.com Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:

Profis Anchor 2.4.6


6 19.03.2014

9 Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like