Light Weight Flexible Lower Cost LCD Display Plug-and-Play Reliable Warranty
At 26 lbs, the FRONIUS IG inverters are the lightest grid-connected inverters making them easy and cost effective to install. The wide voltage range of 150-500 V allows you to use different types of modules and system configuration possibilities. Integrated UL approved DC & AC disconnects which reduce installation time and complexity - often eliminating the need for additional disconnects. User-friendly and comes standard with every FRONIUS IG; tracks more than 20 critical system performance parameters. Expansion slots in the inverter allow you to easily upgrade the inverter with data communication options. Fronius has been in business for over 60 years and has more than 200,000 FRONIUS IG inverters installed worldwide. 10 year Premium Warranty.

POWERING YOUR FUTURE

FRONIUS IG
FRONIUS IG 2000 / 3000 / 2500-LV - Specifications

Internal GFDI, in accordance with UL 1741 Internal diode Internal, in accordance with UL 1741, IEEE 1547 Output power derating Internal DC & AC protection, Tested to 6 kV UL 1741 FCC Part 15; Class A & B UL 1741, IEEE 1547 Compliant with NEC Art. 690 requirements, UL 1741 Two-pole, 15 / 20 A circuit breaker Use maximum AWG 6 194F (90 C) copper wire Use maximum AWG 8 194F (90 C) copper wire 16 A 25 A 10 year Premium Warranty is Standard

Distributed by
Fronius USA LLC
Solar Electronic Division 10421 Citation Drive Suite 1100 Brighton, Mi 48116 Phone: 810-220-4414 Fax: 810-220-4424 E-Mail: pv-us@fronius.com www.fronius-usa.com

40,0006,2438 v01 2010

Text and illustrations technically correct at time of going to print. We reserve the right to make modifications. This document may not be copied or otherwise reproduced, whether in part or in its entirety, without the express prior written consent of Fronius International GmbH.

DC Input Data Recommended PV power Max. DC input voltage Operating DC voltage range Max. usable DC input current AC Output Data Maximum output power @40 C Nominal AC output voltage Utility AC voltage range Maximum AC current Maximum utility back feed current Operating frequency range Total Harmonic Distortion THD Power Factor (cos phi) General Data Max. efficiency Consumption in stand-by Consumption during operation Enclosure Size (l x w x h) Weight Ambient temperature range Cooling Integrated AC and DC disconnects Protections Ground fault protection DC reverse polarity protection Islanding protection Over temperature Surge protection Compliance Safety EMI Anti-Islanding protection Ground fault detector and interrupter Miscellaneous Maximum AC over current protection AC wire sizing DC wire sizing AC disconnect DC disconnect Warranty

FRONIUS IG 2000 1500 2500 Wp 500 V 150 450 V 13.6 A FRONIUS IG 2000 2000 W

FRONIUS IG 3000 2500 3300 Wp 500 V 150 450 V 18 A FRONIUS IG 3000 2700 W

240 V 212 264 V (240 V +10% / -12%) 8.35 A 11.25 A 0.0 A 0.0 A 59.3 60.5 Hz (60 Hz nom) < 5% 1 FRONIUS IG 2000 FRONIUS IG 3000 FRONIUS IG 2500-LV 95.2% 95.2% 94.4% < 0.15 W (night) 7W NEMA 3R 18.5 x 16.5 x 8.8 inches (470 x 418 x 223 mm) 26 lbs. (11.8 kg) -5 to 122 F (-20 to +50 C) controlled forced ventilaton standard UL approved DC & AC disconnects

FRONIUS IG 2500-LV 1800 3000 Wp 500 V 150 450 V 16.9 A FRONIUS IG 2500-LV 2350 W 208 V 183 - 229 V 11.25 A 0.0 A