You are on page 1of 6

BSC6900 Commissioning Checklist The check is complete and the result is normal.

The check is not complete or the result is abnormal. The check is not involved.

Security Level:

Y N N/A

BSC Item

Check the operating status of the hardware. Equipment Verification Checklist

Verify the OMU.

You can log in to the BSC6900 successfully through the LMT. The BSC6900 is connected to the M2000 successfully. The connection mode between the M2000 and the BSC6900 is set to SSL The maintenance mode of the NE is set to Install mode. The configuration data in the OMU database is updated. The license is activated and has passed the verification. BSC6900 Data and Board Software Loading Checklist Load BSC6900 board software and data files.

Verify interfaces through M2000.

GSM Interfaces Verification Checklist

Verify interfaces through LMT.

The Internal Interfaces verification passes. Verify the speech service. GSM Services Verification Checklist 3/28/2014 Verify the data service. Confidential Information of Huawei. No Spreading without Permission

Page1of6

BSC6900 Commissioning Checklist GSM Services Verification Checklist Verify the data service.

Security Level:

Verify the feature services. Other Tasks Verification Checklist The network reliability is verified. There is no active alarm indicating device failure in the alarm console. The maintenance mode of the NE is set to Normal mode.

3/28/2014

Confidential Information of Huawei. No Spreading without Permission

Page2of6

BSC6900 Commissioning Checklist

Security Level:

BSC6900 Commissioning Checklist Item Complete or Not

The cabinet is powered on. The boards are running normally. The fan boxes are running normally. The power monitoring communication board is running normally. The version of the OMU operating system is correct. The OMU software is installed successfully. The OMU is running normally. successfully through the LMT. he M2000 successfully. he M2000 and the BSC6900 is set to SSL. E is set to Install mode. MU database is updated. passed the verification. The .DAT file for loading the BSC6900 is generated. The setting of the loading mode is correct. All the subracks are reset successfully. The consistency check of the data and the version passes. The BSC6900 interfaces are automatically verified on the M2000 side. The Abis interface verification on the BSC6900 side passes. The A interface verification on the BSC6900 side passes. The Gb interface verification on the BSC6900 side passes. The Ater interface verification on the BSC6900 side passes. The Pb interface verification on the BSC6900 side passes. The Lb interface verification on the BSC6900 side passes. The call between an MS and a fixed-line phone is normal. The call between two MSs is normal. Faxes can be received and sent between the MS and the electrograph. Confidential Information of Huawei. No Spreading without Permission

on passes.

3/28/2014

Page3of6

BSC6900 Commissioning Checklist Check the GPRS or EDGE function of the MS. The inter-RAT handover is normal. The location service is normal. The AMR service is normal.

Security Level:

. ng device failure in the alarm console. E is set to Normal mode.

3/28/2014

Confidential Information of Huawei. No Spreading without Permission

Page4of6

BSC6900 Commissioning Checklist

Security Level:

Data Record (Finish Time, Operator, Commissioning Data)/Reason for No Check

3/28/2014

Confidential Information of Huawei. No Spreading without Permission

Page5of6

BSC6900 Commissioning Checklist

Security Level:

3/28/2014

Confidential Information of Huawei. No Spreading without Permission

Page6of6