You are on page 1of 8

Datasheet

Switch on your future...now!

sinext
s

Technical Data

Size
Type Number

S0
3TR30

S1
3TR31

Conformance to standard

3TR32

3TR35

UL, CSA, CE

Rated Insulation Voltage

690

Rated Operational Voltage

690

Rated impulse withstand Voltage

kV

C
C

-55 to +80
-25 to +60

Permissible Ambient Temperature

3TR34

IEC 60947-4-1, IS13947-4-1

Approvals

Storage
Service

Mechanical Life in millions of operations

AC Operation

Electrical Life in millions of operations at 415V, 50Hz, AC3 duty


Rated Operational Current Ie AC1

at 60C, up to 690V

Rated Operational Current Ie AC2/\AC3

at 415V
500V
690V

Max rating of squirrel cage motors


at 50/60Hz
Rated Operational Current Ie AC4
for electrical life of 200,000 operations
Rating of squirrel cage motor at 50/60Hz
(Max permitted rated operational current AC4=AC3
with reduced electrical life)

up to 690V
at 415V
500V
690V

Cycles
Cycles

15

24

20

30

55

A
A
A

9
9
6.6

12
12
8.8

18
18
12.2

25
18
12.2

32
32
27

40
38
27

kW
kW
kW

4
5.5
5.5

5.5
7.5
7.5

9
11
11

12.5
12.5
12.5

17
21
23

21
25
23

3.3

4.3

7.7

8.5

15.6

18.5

kW
kW
kW

1.54
1.7
2.54

2.1
2.5
3.45

3.5
4.6
6

4
5.2
6.6

8.2
9.8
13

9.8
11.8
15.5

Cycle/Hr
Cycle/Hr
Cycle/Hr
Cycle/Hr
Cycle/Hr

10,000
2,000
1,000
1,000
250

10,000
2,000
1,000
1,000
250

5,000
1,500
750
750
250

5,000
1,500
750
750
250

5,000
1,200
750
750
250

5,000
1,200
600
600
200

90

96

144

200

400

400

Max Frequency of operation

No load
AC1
AC2
AC3
AC4

Thermal Loading

10 sec current

Coil Rating at 1.0 x Us


AC Operation 50 Hz

Closing
closed

VA
VA

68
10

101
12.1

Type Number

3UR 5000

3UR 5200

3UR 5500

Suitable for mounting

3TR 30/31

3TR 32/33

3TR 34/35

Ambient Temperature Compensation

Trip Class

-25 to + 60
10A

Rated Insulation Voltage

690

Rated Impulse withstand Voltage

kV

Auxiliary Contacts

S2
3TR33

1NO+1NC

S3

S4

3TR46

3TR47

3TR48

S6
3TR49

3TR50

S8
3TR51

3TR52

S10
3TR53

3TR54

S12
3TR55

IEC 60947-4-1, IS13947-4-1

IEC 60947-4-1, IS13947-4-1

UL, CSA, CE

UL, CSA, CE

1000

1000

1000

1000

-55 to +80
-25 to +60

-55 to +80
-25 to +60

10

3TR56

3TR57

10

16

16

16

16

14

14

12

14

14

14

80

90

100

100

160

160

210

220

300

300

400

550

45
45
45

65
65
65

75
75
75

85
85
75

110
110
110

140
140
140

170
170
170

205
205
170

250
250
250

300
300
250

400
400
400

475
475
400

24.6
30
40

35
42.7
59

42
50.7
70

49
59
70

63.3
76.3
105

78
98
105

98
118
163

120
145
163

147
178
245

174
210
245

236
284
392

273
329
392

24

28

34

45

54

68

75

96

110

125

150

150

13.1
15.8
21.8

15.3
18.4
25.4

18.6
22.4
30.9

23
27
38

29.5
35.5
49

38
46
63

42
50
69

54
65
90

63
76
105

72
86
119

88
107
147

88
107
147

5,000
1,000
600
1,200
400

5,000
1,000
400
1,000
300

5,000
1,000
400
1,000
300

5,000
1,000
350
850
300

5,000
1,000
400
1,000
300

5,000
1,000
300
750
200

5,000
1,000
300
700
200

5,000
1,000
250
500
130

3,000
1,000
300
700
200

3,000
1,000
250
500
130

3,000
1,000
200
500
150

3,000
1,000
170
420
150

360

500

800

800

880

1140

1360

1640

2500

2500

3400

4200

183
17

330
32

550
39

3UR 5800

3UR 5830

3TR 46 to 49

3TR 50

910
58

1430
84

3UR 6230

2450
115

3UR 6830
Independent Mounting

-25 to + 60

-25 to + 60

10A

10A

1000

1000

1NO+1NC

1NO+1NC

SiNext 3TR Power Contactors


Contactor
Size

Rated current (A)


Ie AC3 at 415V,
50 Hz, 3 ph

Auxiliary
Contacts

With AC Coil
Type
(Pls fill in coil voltage code)

Auxiliary
Contacts

Type
(Pls fill in coil voltage code)

1NO$
1NC$

3TR30 10-0A..0-0AA7
3TR30 01-0A..0-0AA7

1NO$
1NC$

3TR30 10-0B..0-0AA7
3TR30 01-0B..0-0AA7

12

1NO$
1NC$

3TR31 10-0A..0-0AA7
3TR31 01-0A..0-0AA7

1NO$
1NC$

3TR31 10-0B..0-0AA7
3TR31 01-0B..0-0AA7

18

-$

3TR32 00-0A..0-0AA7

-$

3TR32 00-0B..0-0AA7

25

-$

3TR33 00-0A..0-0AA7

-$

3TR33 00-0B..0-0AA7

32

-$

3TR34 00-0A..0-0AA7

-$

3TR34 00-0B..0-0AA7

40

45

2NO+2NC$

65

1
2
3
4
6
8
10
12
1)
@
$

3TR35 00-0A..0-0AA7

3TR35 00-0B..0-0AA7

3TR46 22-0A..0-0AA7@

2NO+2NC

3TR46 22-0D..0-0AA7@

2NO+2NC$

3TR47 22-0A..0-0AA7@

2NO+2NC

3TR47 22-0D..0-0AA7@

75

2NO+2NC$

3TR48 22-0A..0-0AA7@

2NO+2NC

3TR48 22-0D..0-0AA7@

85

2NO+2NC$

3TR49 22-0A..0-0AA7@

2NO+2NC

3TR49 22-0D..0-0AA7@

110

2NO+2NC$

3TR50 22-0A..0-0AA7

2NO+2NC

3TR50 22-0D..0-0AA7

140

2NO+2NC

3TR51 22-0A..0-0AA7

2NO+2NC

3TR51 22-0D..0-0AA7

170

2NO+2NC$

3TR52 22-0A..0-0AA7

2NO+2NC

3TR52 22-0D..0-0AA7

205

2NO+2NC$

3TR53 22-0A..0-0AA7

2NO+2NC

3TR53 22-0D..0-0AA7

250

2NO+2NC$

3TR54 22-0A..0-0AA7

2NO+2NC

3TR54 22-0D..0-0AA71)

300

2NO+2NC$

3TR55 22-0A..0-0AA7

2NO+2NC

3TR55 22-0D..0-0AA71)

400

2NO+2NC

3TR56 22-0A..0-0AA7

2NO+2NC

3TR56 22-0D..0-0AA71)

475

2NO+2NC

3TR57 22-0C..0-0AA7

2NO+2NC

3TR57 22-0D..0-0AA71)

Please connect DC coil circuit as recommended.


For box type (SIGUT) terminals, order 2 nos 3TX7 460-OE.
For more aux. contacts, pl. see table below.

AC coil codes : 3TR30 to 35


Coil Voltage
Code

Auxiliary contact block

24V
50Hz

110V
50/60Hz

220V
50Hz

230V
50/60Hz

415V
50Hz

B0

G2

M0

L2

R0

AC coil codes : 3TR46 to 56


Coil Voltage
Code

24V
50Hz

110V
50Hz

220V
50Hz

240V
50Hz

415V
50Hz

B0

F0

M0

U0

R0

Code

110-132
50/60Hz

220-240V
50/60Hz

380-460V
50/60Hz

F7

M7

Q7

3TX4 010-2A

1NC

3TX4 001-2A

1NO (Extd)

3TX4 010-4A

1NC (Extd)

3TX4 001-4A

First 1NO+1NC left

3TY7561-1AA00

First 1NO+1NC right

3TY7561-1BA00

Second 1NO+1NC left

3TY7561-1KA00

Second 1NO+1NC right

3TY7561-1LA00

Coil Voltage

Coil Voltage (V)

24

42

48

110

220

Code

B4

D4

W4

F4

M4

Accessories for SiNext Power Contactors


Interlocking kit for two similar 3TR Contactors
(inclusive of base plate and interlocking mechanism)
For Contactor

Type
Type
091-1A#

AC

DC

Type

24 - 48 V

24 - 70 V

3TX7 402-3GY1

48 - 127V

70 - 150V

3TX7 402-3HY1

127 - 240V

150 - 250V

3TX7 402-3JY1

240 - 400V

3TX7 402-3KY1

400 - 600V

3TX7 402-3LY1

Surge suppressor (Varistor) for 3TR46-56


Less than 48V

24 - 70V

3TX7 462-3GY1

48 - 127V

70 - 150V

3TX7 462-3HY1

127 - 240V

150 - 250V

9/12/18/25/32/40A

3TR30 to 35

3TX4

45/65A

3TR46/47

3TX7 466-1YA0

75/85A

3TR48/49

3TX7 486-1YA0

110/140A

3TR50/51

3TX7 506-1YA0

170/205A

3TR52/53

3TX7 526-1YA0

250/300A

3TR54/55

3TX7 546-1YA0

24 - 48 V

24 - 70 V

3TX7 402-3RY2

400A

3TR56

3TX7 566-1YA0

48 - 127V

70 - 150V

3TX7 402-3SY2

127 - 240V

150 - 250V

W/o base plate (not required)

Spare Main Contacts, Coils and Arc Chambers of 3TR Power Contactors
available upon enquiry
4

1NO

Type

Surge suppressor (Varistor) for 3TR30 to 35

DC coil codes : 3TR30 to 57

AC3 Rating

Description

3TR46 to 57

AC coil codes : 3TR57


Coil Voltage

For
Contactor

3TR30 to 35

Coils suitable for 50/60 Hz upon enquiry

With DC Coil

3TX7 462-3JY1

240 - 400V

3TX7 462-3KY1

400 - 600V

3TX7 462-3LY1

Surge suppressor (RC Unit) for 3TR30 to 35

3TX7 402-3TY2

240 - 400V

3TX7 402-3UY2

400 - 600V

3TX7 402-3VY2

Add-on pneumatic timers for 3TR3 available upon request

SiNext 3UR Bimetal Relays


Current
Setting Range
(A)

Type Reference

3UR 5000
For direct mounting on contactor 3TR30/31 or individual mounting
with 3UX1418

Current
Setting Range
(A)

Type Reference

3UR58 00
For direct mounting on contactor 3TR46 to 49 or individual mounting
with 3UX1421

0.1 - 0.16

3UR50 00-0A A00-0AA7

16 - 25

3UR58 00-2C A00-0AA7

0.16 - 0.25

3UR50 00-0C A00-0AA7

20 - 32

3UR58 00-2D A00-0AA7

0.25 - 0.4

3UR50 00-0E A00-0AA7

25 - 40

3UR58 00-2E A00-0AA7

0.4 - 0.63

3UR50 00-0G A00-0AA7

32 - 50

3UR58 00-2F A00-0AA7


3UR58 00-2T A00-0AA7

0.63 - 1

3UR50 00-0J A00-0AA7

40 - 57

0.8 - 1.25

3UR50 00-0K A00-0AA7

50 - 63

3UR58 00-2P A00-0AA7

1 - 1.6

3UR50 00-1A A00-0AA7

57 - 70

3UR58 00-2V A00-0AA7

1.25 - 2

3UR50 00-1B A00-0AA7

63 - 80

3UR58 00-2U A00-0AA7

1.6 - 2.5

3UR50 00-1C A00-0AA7

70 - 95

3UR58 00-8Y A00-0AA7

2 - 3.2

3UR50 00-1D A00-0AA7

2.5 - 4

3UR50 00-1E A00-0AA7

3.2 - 5

3UR50 00-1F A00-0AA7

4 - 6.3

3UR50 00-1G A00-0AA7

5-8

3UR50 00-1H A00-0AA7

70 - 95

3UR58 30-5B A00-0AA7

6.3 - 10

3UR50 00-1J A00-0AA7

85 - 105

3UR58 30-5C A00-0AA7

8 - 12.5

3UR50 00-1K A00-0AA7

95 - 120

3UR58 30-5D A00-0AA7

10 - 14.5

3UR50 00-2S A00-0AA7

3UR 5200
For direct mounting on contactor 3TR32/33 or individual mounting
with 3UX1420
1 - 1.6

3UR52 00-1A A00-0AA7

3UR58 30
For direct mounting on contactor 3TR50 or individual mounting with
3UX1421 0XA

3UR62 30
Individual mounting
85 - 135

3UR62 30-5A A00-0AA7

115 - 180

3UR62 30-5B A00-0AA7

160 - 250

3UR62 30-5C A00-0AA7

200 - 320

3UR62 30-5D A00-0AA7

250 - 400

3UR62 30-5E A00-0AA7

1.25 - 2

3UR52 00-1B A00-0AA7

1.6 - 2.5

3UR52 00-1C A00-0AA7

2 - 3.2

3UR52 00-1D A00-0AA7

2.5 - 4

3UR52 00-1E A00-0AA7

3.2 - 5

3UR52 00-1F A00-0AA7

4 - 6.3

3UR52 00-1G A00-0AA7

5-8

3UR52 00-1H A00-0AA7

320 - 500

3UR68 30-5F A00-0AA7

400 - 630

3UR68 30-5G A00-0AA7

6.3 - 10

3UR52 00-1J A00-0AA7

8 - 12.5

3UR52 00-1K A00-0AA7

10 - 16

3UR52 00-2A A00-0AA7

12.5 - 20

3UR52 00-2B A00-0AA7

16 - 25

3UR52 00-2C A00-0AA7

3UR68 30
Individual mounting

Accessories for SiNext Birelays


3UR55 00
For direct mounting on contactor 3TR34/35 or individual mounting
with 3UX1425
10 - 16

3UR55 00-2A A00-0AA7

12.5 - 20

3UR55 00-2B A00-0AA7

16 - 25

3UR55 00-2C A00-0AA7

20 - 32

3UR55 00-2D A00-0AA7

25 - 36

3UR55 00-2Q A00-0AA7

32 - 40

3UR55 00-2R A00-0AA7

36 - 45

3UR55 00-8M A00-0AA7

Description

For Relay type

Type

Accessory for
independent
mounting

3UR50
3UR52
3UR55
3UR58
3UR58 30

3UX14 18
3UX14 20
3UX14 25
3UX14 21
3UX14 21-0XA

Resetting Plunger
Funnel

3UR

3UX10 11
3UX10 13

Reset cord + holder:


400 mm length
600 mm length

3UR

3UX10 15
3UX10 16

Dimension Drawings
3TR30/31 with AC coil + 3UR50

* With Aux. Contact block type 3TX4...


** With Relay type 3UR50...

3TR32/33 with AC coil + 3UR52

3TR30/31 with DC coil

3TR32/33 with DC coil

* With Aux. Contact block type 3TX4...


** With Relay type 3UR52...

3TR34/35 with AC coil + 3UR55

* With Aux. Contact block type 3TX4...


** With Relay type 3UR55...
6

With Aux. Contact block type 3TX4...

With Aux. Contact block type 3TX4...

With Aux. Contact block type 3TX4...

3TR34/35 with DC coil

Dimension Drawings
3TR46 and 47

3TR52 and 53

a1

3TR48 and 49

3TR52

20

42

174

154

3TR53

25

48

184

159

a1

a2

b1

b2

3TR54 and 55

a1

a2

3TR48

10,5

26,5

127

116

3TR49

10,5

26,5

127

116

3TR50 and 51

a1

a2

3TR56 and 57

a2

b3

b4

3TR50

15

37

149

134

3TR56

25

48

203

200

178

3TR51

20

42

159

139

3TR57

30

52

215

110,5

100

182
7

Dimension Drawings
3TR46-49 + 3UR5800

a2

a3

b1

3TR50 + 3UR5830

3UR5800

a1

3TR46, 3TR47

90 113 70 117 175 100 126 10.5 26.5 25 102 31.5 80 63 122 28 4.8 6.1

b2

b3

c1

d1

d2

d3

e1

f1

f2

f3

g g1 g2

3TR48, 3TR49

100 123 80 127 194 110 143 10.5 26.5 25 116 31.5 89 71 132 39 5.5 6.1

3UR6230 and 3UR6830CT operated relay

Relay Type

3UR62

3UR68

Range

85 135 A
115 180 A

20

134.5

160 250 A
200 320 A
250 400 A

25

134.5

320 600 A
400 630 A

30

137.5

** Dimension for square OFF-button (Stroke 3mm)


Dimension for round RESET-button (Stroke 2.5mm) less 2.5

Siemens Ltd.
Automation and Drives Division
LV Control & Distribution Products
Thane Belapur Road
Thane 400601
Fax : +91 22 27623729
e-mail : A&D-BDCD.in@siemens.com
Siemens Ltd.

SGR-01-101-084

Product development is a continuous process. Consequently,


the data indicated in this datasheet is subject to change without
prior notice. For latest issue contact our Sales Offices.

You might also like