RESCO500+A is an antiscalent for reverse osmosis and nanofiltration membranes that controls carbonate, sulfate, and silica scales. It can significantly increase allowable system recoveries and expand the suitable range of applications. The product is dosed into the feed water prior to filters and pumps, typically between 5-10 ppm. It is a clear light yellow anionic polymer liquid packaged in 20 kg containers.
RESCO500+A is an antiscalent for reverse osmosis and nanofiltration membranes that controls carbonate, sulfate, and silica scales. It can significantly increase allowable system recoveries and expand the suitable range of applications. The product is dosed into the feed water prior to filters and pumps, typically between 5-10 ppm. It is a clear light yellow anionic polymer liquid packaged in 20 kg containers.
RESCO500+A is an antiscalent for reverse osmosis and nanofiltration membranes that controls carbonate, sulfate, and silica scales. It can significantly increase allowable system recoveries and expand the suitable range of applications. The product is dosed into the feed water prior to filters and pumps, typically between 5-10 ppm. It is a clear light yellow anionic polymer liquid packaged in 20 kg containers.
Superior control of carbonate and sulfate scales Iron and silica antiscalent capability PROBLEM In many installations worldwide, higher permeate recoveries from reverse osmosis (RO) Systems are often limited by the potential for the sulfate scales. This is especially problematic for waters with high amounts of silica or metal hydro ides, which can form insoluble polymeric gels with conventional scale inhibitors. In many applications, the tendency for sulfate scale formation has the effect of lowering the system recovery that could adversely affect the system economics. SOLUTION RESCO500+A protects and enhances the operation of RO and !" systems mineral scale formation due to carbonate, sulfate and fluoride compounds. In most water types, proper use of RESCO500+A can significantly increase allowable system recoveries and thus e pand the suitability for use in wider range of applications. APPLICATION RESCO500+A is motored into the feed water at a point where turbulent flow will ensure ade#uate chemical mi ing prior to entering the RO and !" systems. This is usually done prior to the cartridge filters and high pressure pump. $osing rate vary depending on feed water and recovery but normally run between % & ' ppm. TYPICAL PROPERTIES (hemical composition *ppearance Ionicity p+ Specific /ravity )olymer compound (lear light yellow li#uid *nionic , - ..' 0.1 & 0.0
Question 21 We Are Observing Fouling of Our Feedeffluent Exchangers That Has Impacted Heat Transfer and Restricted Feed What Are Potential Contributing Causes and How Can We Mitigate