You are on page 1of 6

Bauvorhaben:

Psi-Therm 2011
Datum: 9.11.2012

Wrmebrckenberechnung (f-Wert)

Nr. U1 U2

Name U1 U2

Lnge 1.000 m 1.000 m

U-Wert 0.24 W/(mK) 0.27 W/(mK)

Korrekturfaktor F_e (1.00) F_e (1.00)

Mindestwrmeschutz nach DIN 4108-2 ist erfllt.


fRSI = 0.91 > 0,7
Xella Deutschland GmbH

Seite:

Bauvorhaben:

Psi-Therm 2011
Datum: 9.11.2012 Materiallegende: Name Normal concrete (2400) Normal mortar YTONG Multipor light mortar YTONG Multipor mineral insulation board WI Normal mortar YTONG plan block PPW 2 / 0, 40 - 0.10 Randbedingungen und Wrmestrme: Nr Temp R1 -R2 -R3 -15.00 C R4 20.00 C Mindestwrmeschutz nach DIN 4108-2 kritische Oberflchentemperatur (Tsi) f-Wert

Lambda 2.100 W/(mK) 0.870 W/(mK) 0.180 W/(mK) 0.045 W/(mK) 1.000 W/(mK) 0.100 W/(mK)

Rsi/Rse --0.04 0.25

Lnge 0.42 m 0.42 m 2.00 m 2.00 m

Wrmestrom ---18.247 W/m 18.247 W/m

+17.00 C 0.91

Xella Deutschland GmbH

Seite:

Bauvorhaben:

Psi-Therm 2011
Datum: 9.11.2012 Eingabedaten - Materialbereiche Bild Name M1
Name Contour

Lambda 2.100 W/(mK)


Nr 1 2 3 4 X +0.34 m +0.09 m +0.09 m +0.34 m Y +0.66 m +0.66 m -0.34 m -0.34 m

Normal concrete (2400)

Bild M2
Name Contour

Name Normal mortar


Nr 1 2 3 4 X +0.35 m +0.34 m +0.34 m +0.35 m +0.35 m +0.34 m +0.34 m +0.35 m

Lambda 0.870 W/(mK)


Y +0.66 m +0.66 m -0.34 m -0.34 m +1.66 m +1.66 m +0.66 m +0.66 m

Contour

1 2 3 4

Bild M3
Name Contour

Name YTONG Multipor light mortar


Nr 1 2 3 4 X +0.09 m +0.09 m +0.09 m +0.09 m -0.06 m -0.07 m -0.07 m -0.06 m

Lambda 0.180 W/(mK)


Y +0.66 m +0.66 m -0.34 m -0.34 m +0.66 m +0.66 m -0.34 m -0.34 m

Contour

1 2 3 4

Bild M4
Name Contour

Name YTONG Multipor mineral insulation board WI


Nr 1 2 3 4 X +0.09 m -0.06 m -0.06 m +0.09 m

Lambda 0.045 W/(mK)


Y +0.66 m +0.66 m -0.34 m -0.34 m

Bild M5
Name Contour Xella Deutschland GmbH

Name Normal mortar


Nr 1 2 3 4 X -0.06 m -0.07 m -0.07 m -0.06 m

Lambda 1.000 W/(mK)


Y +1.66 m +1.66 m +0.66 m +0.66 m

Seite:

Bauvorhaben:

Psi-Therm 2011
Datum: 9.11.2012 Eingabedaten - Materialbereiche Bild Name M6
Name Contour

Lambda 0.100 W/(mK)


Nr 1 2 3 4 X +0.34 m -0.06 m -0.06 m +0.34 m Y +1.66 m +1.66 m +0.66 m +0.66 m

YTONG plan block PPW 2 / 0, 40 - 0.10

Eingabedaten - Randbereiche Name R1 adiabat


Starting point Endpoint

Temperature -X -0.07 m +0.35 m

Rsi/Rse -Y

Lnge 0.42 m
-0.34 m -0.34 m

R2
Starting point Endpoint

Name adiabat

Temperature -X +0.35 m -0.07 m

Rsi/Rse -Y

Lnge 0.42 m
+1.66 m +1.66 m

R3
Starting point Endpoint

Name Outside free input

Temperature -15.00 C
X -0.07 m -0.07 m

Rsi/Rse 0.04
Y

Lnge 2.00 m
+1.66 m -0.34 m

R4
Starting point Endpoint

Name The outer walls, inner walls

Temperature +20.00 C
X +0.35 m +0.35 m

Rsi/Rse 0.25
Y

Lnge 2.00 m
-0.34 m +1.66 m

Eingabedaten - U-Werte Name U1 U1 X +0.34 m Name U2 X +0.35 m

U-Wert 0.24 Y +1.10 m U-Wert 0.27 Y +0.11 m Ausrichtung 180 Ausrichtung 180

Fx 1.00

U2

Fx 1.00

Xella Deutschland GmbH

Seite:

Bauvorhaben:

Psi-Therm 2011
Datum: 9.11.2012
********************************************************************** f - VALUE CALCULATION ********************************************************************** N E T W O R K G E N E R A T I O N Combining the thermal bridge areas... ready Generation of the element cells There were : 3031 Element cells produced. Topology optimization... ready E N D : N E T W O R K G E N E R A T I O N Assembling the finite element structure... ready Number of Elemente_____:4156 Number of Knoten_______:2225 S T A R T : F I N I T E E L E M E N T C A L C U L A T I O N Initialize matrices...Number of nodes 2225 Assembling the stiffness matrix and load vector... ready Begin the iteration. According to the method of conjugate gradient: ... Done, the system of equations was solved. Number of iterations 470 The temperatures in the network nodes are calculated. E N D : F I N I T E E L E M E N T C A L C U L A T I O N ********************************************************** *** CONVERGENCE TEST ********************** *** To DIN10211:2008-04, A.2 ********************** Convergence - structure... ready Number of Elemente_____:16624 Number of Knoten_______:8605 S T A R T : F I N I T E E L E M E N T C A L C U L A T I O N Initialize matrices...Number of nodes 8605 Assembling the stiffness matrix and load vector... ready Begin the iteration. According to the method of conjugate gradient: ... Done, the system of equations was solved. Number of iterations 1151 The temperatures in the network nodes are calculated. E N D : F I N I T E E L E M E N T C A L C U L A T I O N Sum of absolute values of all penetrating heat flows: from the baseline [W/m]:18.26 from the Konvergenzberechung [W/m]:18.247 Convergence [%] 0.1 <= 1 ============================== ********************************************************** *** S U R F A C E T E M P E R A T U R E S ****** Boundary conditions Boundary condition Type Heat flow Length Temperature Rs(i,e) Calculation of heat flows 1 Neumann 0.00 0.42 --4 Robin 18.25 2.00 20.00 0.25 3 Robin -18.25 2.00 -15.00 0.04 2 Neumann 0.00 0.42 --Minmal surface temperatures: Indoors 17.00[C] at position : X 0.35[m] Y 0.59[m] ========= Outdoors -14.72[C] at position : X -0.07[m] Y 0.64[m] ========= Minimum Insulation according to DIN 4108-2 for 2-temperature conditions: critical surface temperature (Tsi): 17.00 [C]

Xella Deutschland GmbH

Seite:

Bauvorhaben:

Psi-Therm 2011
Datum: 9.11.2012
(Ti) : 20.00 [C] (Te) : -15.00 [C] = 0.91 > 0.7 ============ ********************************************************** *** E N D of C A L C U A L T I O N *** ********************************************************** Room temperature Outdoor temperature f_Rsi = (Tsi-Te) / (Ti-Te)

Xella Deutschland GmbH

Seite: