Air-cooled condensers Dry coolers

More efficient More flexible More intelligent

Less energy Less time Less noise


Capacity: up to

1100 kW

USE
The drycoolers in the OPERA range are mainly designed for cooling water or glycol/water mix for: - condensers for water chillers, - generators, - processes or machines (presses, compressors, etc.), - free cooling. The air-cooled condensers in the OPERA range are mainly designed for the condensation of refrigerants for water chillers, as a split system.

DESCRIPTION
- Galvanised steel casing, with RAL 7035 paint - Copper tubes, aluminium fins - Hydraulic connection via swivel brackets (drycoolers) - Anti-shear system for bundle tubes - Individual partitioning of the fan motor assemblies - Electrical connection to the motor terminal box

Excellent resistance to corrosion


- Galvanised steel casing with polyester paint on 2 sides - Assembled using stainless steel rivets - Copper manifolds - Stainless steel flanges (drycoolers) - Protective enclosures on the elbows and manifolds

The range of choice


OPERA is a modular range available with: - 1 to 14 fans - 3 housing lengths - Several propeller diameters up to 910 mm - Several rotation speeds from 300 to 900 rpm. This vast range of combinations can be used to optimise either electrical consumption or the sound level.

Fan motor assemblies


- Profiled collars and aerodynamic propellers benefiting from the latest developments and contributing to a reduced sound level and improved efficiency.

Air
- Each coil is air tested underwater. - Rotation tests, dielectric tests, measuring current for motors with a wiring option.

DESIGNATION (EXAMPLE) O P ER A D L N 9 1 2 4 -2S H I 4 3 0 A


A: motor type (A=AC motor) 430: Rotation speed I: Draught (I=Induced, F=Forced) H: Position (H=Horizontal, V=Vertical) S: Coil feature (S=Single, D=Double, T=Twin, Z=Drainable) 2: Number of fan lines (1 or 2) 4: Number of coil rows 12: Number of fans 9: Impeller diameter (8=800, 9=900 mm) N: Design (N=Standard, X=Non standard) D: Function (D=Drycooler, C=Condenser)
HEATPUMPS- AIR CONDITIONING - reFrigeration - air handLing - heat eXchange - na 13.689 a

L: Module size (S=Short, M=Medium, L=Long)

OPERA

MORE for LESS

Air-cooled condensers Dry coolers


OPTIONS
FOR EACH APPLICATION
Adaptability
- Maintenance switches - Raised feet - Vertical position - Forced draught - Double circuit - Expansion vessel - Drainable bundle

OPERA

IP54 electrical cabinets fitted and cabled


- Protection cabinet with 1 general disconnector, 1 magnetic circuit breaker per fan line, connection for motor PTOs 1 fault summary, 3-phase 400V 50Hz power supply. - Aeroconnect control cabinet with 1 general disconnector,1 magnetic circuit breaker per fan line, 1 switch per stage, connection for motor PTOs, control by Aeroconnect board, 1 fault summary, from 2 to 7 stages depending on unit, 3-phase 400V 50Hz + N power supply. Main functions of Aeroconnect: temperature or pressure control, communication via bus connection with BMS or CIAT chiller (MODBUS protocol), balancing of the stage running times, 2 setpoints, free cooling management, misting management, console with LCD screen facilitating parameter setting and access to operating information (setpoint, temperature or pressure, etc.) or to faults. If the unit is linked to a CIAT chiller, ensure a shielded cable is used for connection. - Control cabinet with stages on terminals with 1 general disconnector,1 magnetic circuit breaker and 1 switch per stage, connection for motor PTOs, from 2 to 7 stages depending on unit, 1 fault summary, 3-phase 400V 50Hz + N power supply.

Protection
- Fin protective screen - Precoated aluminium fins - High efficiency coating (Altena) on the finned bundle

EC motors
The new generation of EC motors enables progressive control from 0 to 100% by speed variation and brings significant benefits in terms of energy savings and reduced sound levels.
Effects on the sound level
On/Off control Reduction in noise (dBA)

Energy savings
On/Off control

Options for cabinets


- 400V / 230V transformer for supplying power to the cabinet on sites with no neutral. - Energy metre.

mo

tor

EC

wi

Power input

ol

Co

flow rate

HEATPUMPS- AIR CONDITIONING - reFrigeration - air handLing - heat eXchange - na 13.689 a

Co

nt

flow rate

ntr

ro

lw

ith

EC

th

ot

or

Air-cooled condensers Dry coolers


DIMENSIONS

E: 1240 (1 fan line), 2360 (2 lines) F: 1280 (1 fan line), 2400 (2 lines)

S MODULES 9010-1 A B C D 830 950 9020-1 1780 1900 9030-1 2730 2850 9040-1 1840 3680 3800 9050-1 1840 2790 4630 4750 9040-2 1780 1900 9060-2 2730 2850 9080-2 1840 3680 3800 9100-2 1840 2790 4630 4750 9120-2 2790 5580 5700 9140-2 1840 4690 6530 6650

M MODULES 9010-1 A B C D 1480 1600 9020-1 3080 3200 9030-1 4680 4800 9040-1 3140 6280 6400 9050-1 3140 4740 7880 8000 9040-2 3080 3200 9060-2 4680 4800 9080-2 3140 6280 6400 9100-2 3140 4740 7880 8000 9120-2 4740 9480 9600 9140-2 3140 7940 11080 11200

L MODULES 9010-1 A B C D 1780 1900 9020-1 3680 3800 9030-1 5580 5700 9040-1 3740 7480 7600 9050-1 3740 5640 9380 9500 9040-2 3680 3800 9060-2 5580 5700 9080-2 3740 7480 7600 9100-2 3740 5640 9380 9500 9120-2 5640 11280 11400 9140-2 -

HEATPUMPS- AIR CONDITIONING - reFrigeration - air handLing - heat eXchange - na 13.689 a

OPERA

Air-cooled condensers Dry coolers


SOUND
Rotation speeds (rpm) MODELS 9010-1 9020-1 9030-1 9040-1 9050-1 9040-2 9060-2 9080-2 9100-2 9120-2 9140-2 Y 77 / 44 80 / 47 82 / 49 83 / 50 84 / 51 83 / 50 85 / 52 86 / 53 87 / 54 88 / 55 88 / 55

OPERA
700/900 560/690 D 82 / 49 85 / 52 87 / 54 88 / 55 89 / 56 88 / 55 90 / 57 91 / 58 92 / 59 93 / 60 93 / 60 Y 66 / 33 69 / 36 71 / 38 72 / 39 73 / 40 72 / 39 74 / 41 75 / 42 76 / 43 77 / 44 77 / 44 D 71 / 38 74 / 41 76 / 43 77 / 44 78 / 45 77 / 44 79 / 46 80 / 47 81 / 48 82 / 49 82 / 49 Y 55 / 22 58 / 25 60 / 27 61 / 28 62 / 29 61 / 28 63 / 30 64 / 31 65 / 32 66 / 33 66 / 33 340/430 D 62 / 29 65 / 32 67 / 34 68 / 35 69 / 36 68 / 35 70 / 37 71 / 38 72 / 39 73 / 40 73 / 40

LEVELS
SOUND POWER LEVELS* / SOUND PRESSURE LEVELS** dB(A) 690/900 D 83 / 50 86 / 53 88 / 55 89 / 56 90 / 57 89 / 56 91 / 58 92 / 59 93 / 60 94 / 61 94 / 61 Y 73 / 40 76 / 43 78 / 45 79 / 46 80 / 47 79 / 46 81 / 48 82 / 49 83 / 50 84 / 51 84 / 51 680/890 D 81 / 48 84 / 51 86 / 53 87 / 54 88 / 55 87 / 54 89 / 56 90 / 57 91 / 58 92 / 59 92 / 59 Rotation speeds (rpm) MODELS 8010-1 8020-1 8030-1 8040-1 8050-1 8040-2 8060-2 8080-2 8100-2 8120-2 8140-2 Y 75 / 42 78 / 45 80 / 47 81 / 48 82 / 49 81 / 48 83 / 50 84 / 51 85 / 52 86 / 53 86 / 53

(*) Only the sound power level is characteristic of the unit. These values are obtained in compliance with the ISO 3744 standard. (**) Values measured at 10 m for horizontal units in free field, directivity 2, in line with the coil. Tolerance 3dB. The difference between the sound power level and pressure level varies according to the site. To determine the units sound pressure level, recalculate it using the sound power level of the unit and the conditions of the site (you may need to consult an acoustical engineer). As the sound emitted by the unit is not uniform in all directions, for a point 10 m away in line with the fans, the recalculated pressure value must be increased by approximately 4 dB.

INSTALLATION

RECOMMENDATIONS
l For air-cooled condensers, the calculation of the evacuation capacity of the air-cooled condenser must be carried out in accordance with professional best practice and particularly in accordance with: - the type of compressor in the installation (hermetic, semihermetic or open), - the horizontal and vertical lengths of the connection pipes and their diameter. l Commissioning and maintenance: refer to the installation, operating and maintenance manual. l These units comply with the European directives. The installer is responsible for ensuring the compliance of the installation. The installer must ensure safety and protective devices (emergency stop, shut-off valves, lightning protection, etc.) are put in place and are accessible.

l These units are designed to operate outside. When starting up, frost and snow could adversely affect the operation of horizontal units. As a general measure, all steps should be taken to avoid the risk of air recycling. This is especially so when the installation comprises several units. It is not recommended to install units near the hot air extraction duct outlet or close to deciduous plants (this could cause clogging). l A horizontal unit must have a surrounding free area of 1.5 m. Where the use of anti-vibration mounts is required, use a rigid frame which locks the feet together. l A vertical unit should preferably be placed parallel to the direction of the wind. It is not recommended for use with low fan rotation speeds. In addition, we recommend that these units be stabilised using braces connecting their two upper ends to fixed supports (wall or framework). l If speed regulators other than those recommended by CIAT are used, their compatibility with the electric motors must be verified.

This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification.

Head office

Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42 Fax: +33 (0)4 79 42 42 10 info@ciat.fr - www.ciat.com

Tel. : 08 11 65 98 98 (0,15 / mn) Fax : 08 26 10 13 63 (0,15 / mn)

CIAT Service

Compagnie Industrielle dApplications Thermiques - S.A. with a registered capital of 26 728 480 - R.C.S. Bourg-en-Bresse B 545 620 114

HEATPUMPS- AIR CONDITIONING - reFrigeration - air handLing - heat eXchange - na 13.689 a