Fiber Optic Cable Sensor

UF88VCF3
Part Number

Technical Data
Optical Data
Range Switching Hysteresis Light Source Service Life (T = +25 C) Max. Ambient Light Opening Angle 2000 mm < 15 % Infrared Light 100000 h 12 10000 Lux

Electrical Data
Supply Voltage

Current Consumption (Ub = 24 V) Switching Frequency Response Time On-/Off-Delay

10...30 V DC < 40 mA 1 kHz 500 s 0...1 s < 10 %

Temperature Drift

Temperature Range

Switching Output Voltage Drop

-10...60 C < 2,5 V 200 mA yes yes yes III

Switching Output/Switching Current Residual Current Switching Output Short Circuit Protection Overload Protection Protection Class Reverse Polarity Protection

< 50 A

Adaptable for glass fiber optic cables: reflex and through beam mode Adjustable time delay Large detection range Switching frequency: 1 kHz

Mechanical Data
Housing Material

Full Encapsulation Connection

CuZn, nickel-plated yes IP65

Degree of Protection PNP NO/NC switchable Connection Diagram No. Control Panel No. Suitable Connection Technology No. Suitable Mounting Technology No. Suitable Fiber Optic Cable Adapter No.

M12 1; 4-pin

104 F3 Fo2 2 130 01

These sensors are equipped for use with glass fiber optic cables but can be used with or without one. The transmitter and receiver are located in a single housing. The sensor evaluates transmitted light reflected back from the object and the output is switched as soon as an object passes the selected range. Bright objects reflect more light than dark objects, and can thus be recognized from greater distances.

Photoelectronic Sensors

All dimensions in mm (1 mm = 0.03937 Inch)


104

Legend
Supply Voltage + Supply Voltage 0 V Supply Voltage (AC Voltage) Switching Output Switching Output Contamination/Error Output Contamination/Error Output Input (analog or digital) Teach Input Time Delay (activation) Shielding Interface Receive Path Interface Send Path Ready Ground Clock Output/Input programmable Power over Ethernet Safety Input Safety Output Signal Output not connected Test Input Test Input inverted Trigger Input Analog Output Ground for the Analog Output Block Discharge Valve Output Valve Control Output + Valve Control Output 0 V Synchronization Receiver-Line Emitter-Line Grounding Switching Distance Reduction Ethernet Receive Path Ethernet Send Path Interfaces-Bus A(+)/B() Emitted Light disengageable Magnet activation Input confirmation Contactor Monitoring

(NO) (NC) (NO) (NC)

Wire Colors according to DIN IEC 757


Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Green Yellow

Complementary Products
Glass Fiber Optic Cable

Ctrl. Panel
F3

Optic
Fo2
Specifications are subject to change without notice

10

01 05 11

08

01 = Switching Status Indicator 11 = ON-Delay/OFF-Delay Adjuster 05 = Switching Distance Adjuster 08 = NO/NC Switch 10 = ON-Delay/OFF-Delay Switch

You might also like