Technical Documentation
Product family Tellabs

6300 Managed
Transport System
Product name Tellabs

6310 Edge Node


Title Flexible Version, 2U High
Document Hardware Installation Manual
MA322 / Revision F1
2 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
Legal Notices
Legal Notices
Copyright Statement This Tellabs manual is owned by Tellabs or its licensors and protected by U.S.
and international copyright laws, conventions, and treaties. Your right to use
this manual is subject to limitations and restrictions imposed by applicable li-
censes and copyright laws. Unauthorized reproduction, modification, distri-
bution, display or other use of this manual may result in criminal and civil
penalties.
Trademark Notice The following trademarks and service marks are owned by Tellabs Opera-
tions, Inc., or its affiliates in the United States and/or other countries: AUDIO
PLUS

, CABLESPAN

, CEC-128, DYNAMIC SIGNAL TRANSFER,


DXX

, DXX logo

, EC DUO

, ENHANCED AUDIO PLUS

, EX-
PRESS/PATH

, FOCUS, MARTIS

, MARTISDXX

, MARTIS logo

, MAR-
TISDXX logo

, METROVANTAGE

, METROWATCH, NETREACH

,
NETWISE

, SCULPTURED SOUND, TELLABS

, TELLABS and T sym-


bol

, T symbol, TELLABS PROPARTNER, TEL/MAP, TEL/MOR

, THE
WORLD COMMUNICATES THROUGH TELLABS, TITAN

, VERITY,
YOUR NETWORKING PARTNER

.
Any other company or product names may be trademarks of their respective
companies.
MA322 Rev. F1 3
Tellabs

6310 Edge Node


Flexible Version, 2U High
Environmental Notices
Environmental Notices
Instructions for use,
maintenance and
management of residual
product
The equipment covered in this manual has been designed to fulfil the environ-
mental demands of market and society. There are no apparent hazards during
use and on-site maintenance of the equipment. We recommend that repair of
defective equipment takes place at Tellabs premises, and it is likewise recom-
mended to dispose of the equipment by use of certified local waste contractors
that can assure environmental safe handling and disposal of the equipment.
Arrangement for disposal of equipment can also be made through Tellabs.
Waste handling in
member states of the
European Union
The equipment covered in this manual must be disposed of in accordance
with "Directive 2002/96/EC of the European Parliament and of the council of
27 January 2003 on waste electrical and electronic equipment (WEEE)".
Disposal must follow national legislation for "IT and telecommunications
equipment" in accordance with the WEEE directive.
Do not dispose of waste electrical and electronic equipment with unsorted
municipal and household waste
Collect the equipment separately
Return the equipment through the collection system agreed with Tellabs.
Correct handling of the disposed equipment contributes to reuse, recycling
and other form of recovery to protect the environment.
Label The equipment is marked with the figure shown below, to indicate that the
equipment must be collected separately. In case of very small products, the
figure may only be on the packaging or in this manual. The Tellabs name and
the production date will also be labelled on the product.
Further information For further information about separation and handling the disposed equip-
ment to ensure correct reuse or recycling, please look at www.tellabs.com.
4 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
Revision Information
Revision Information
Revision history This manual has changed as follows:
Rev. Date Description of Changes
A1 Sept. 27, 2002 First version.
B1 Nov. 8, 2002 Compared to revision A1:
Procedures and descriptions have been updated
to include the 10/100 Ethernet interface option
ETEX4.
Minor changes have been performed.
C1 June 30, 2003 Compared to revision B1:
Procedures and descriptions have been updated
to include the tributary option ETEX8S, that
provides 4 x 10/100 BaseT Ethernet and 2 x 100
BaseFX Ethernet.
Procedure describing how to replace an electri-
cal tributary module has been added.
Minor changes have been performed.
D1 Oct. 24, 2003 Compared to revision C1:
Procedures and descriptions have been updated
to include the tributary option ETEX8M, that
provides 4 x 10/100 BaseT Ethernet and 2 x 100
BaseFX Ethernet.
Procedures and descriptions have been updated
to include the tributary option ETEX2S, that
provides 2 x 1000 BaseSX/LX Ethernet.
Procedure describing how to pack module be-
fore sending it has been added.
Minor changes have been performed.
D2 Dec. 10, 2004 Compared to revision D1:
Specifications for the optical STM-1 and STM-4
interfaces have changed.
Specifications for ETEX transceivers have been
added.
Minor changes have been performed.
E1 March 13, 2006 Compared to revision D2 the manual has changed
as follows:
Optical cables have been changed.
Minor changes have been performed.
MA322 Rev. F1 5
Tellabs

6310 Edge Node


Flexible Version, 2U High
Revision Information
F1 Aug. 31, 2006 Compared to revision E1 the manual has changed
as follows:
The following interface options of the Tellabs
6310 node have been removed from the manual:
LI1 (1 x STM-1 tributary), RI1 (2 x STM-1 tribu-
tary) and TEX4 (140 Mbit/s).
Minor changes have been performed in connec-
tion with introduction of feature pack 6.2.
Rev. Date Description of Changes
6 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
Revision Information
MA322 Rev. F1 7
Tellabs

6310 Edge Node


Flexible Version, 2U High
Warnings and Cautions
Warnings and Cautions
Laser radiation Be aware of the warnings described here when installing and performing ser-
vice on the equipment. The following rules describe how to avoid hazardous
situations.
Warning Please note the following warning.
Caution Please note the following caution.
The equipment has been designed for connection to an IT power system.
8 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
Warnings and Cautions
Tellabs

6310 Edge Node


Flexible Version, 2U High
Contents
MA322 Rev. F1 9
Legal Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Environmental Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Revision Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Purpose of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Structure of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Definition of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.2 Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2 Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.1 Optical Safety Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.2 Labels on Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.3 Physical Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.4 Installing the Tellabs 6310 Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2.4.1 Mounting the Tellabs 6310 Node in the Rack . . . . . . . . . . . . . 20
2.4.2 Connecting the Cables to the Tellabs 6310 Node . . . . . . . . . 23
2.4.3 Identification Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.5 Replacing the Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.6 Replacing the Tributary Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3 Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3.1 Front Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3.2 Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
3.3 LEDs and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
3.4 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
3.5 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
3.5.1 STM-4 and STM-1 Optical Interfaces . . . . . . . . . . . . . . . . . . . 43
3.5.2 PDH Electrical Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
3.5.3 Ethernet Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
3.5.4 Synchronization Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
3.5.5 Management Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
3.5.6 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
3.5.7 Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
3.5.8 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
3.5.9 EMC Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
3.5.10 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
3.5.11 R&TTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
3.5.12 MTBF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
A Packing Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Tellabs

6310 Edge Node


Flexible Version, 2U High
Contents
10 MA322 Rev. F1
MA322 Rev. F1 11
Tellabs

6310 Edge Node


Flexible Version, 2U High
Preface
Preface
Introduction This preface describes the purpose of the manual and how the manual is struc-
tured. Furthermore you will find explanations of abbreviations, definition of
terms and references used in the manual.
Purpose of the Manual on page 11
Structure of the Manual on page 11
Abbreviations on page 11
Definition of Terms on page 12
References on page 13
Purpose of the Manual
Purpose The purpose of this manual is to:
Inform the user how to install and connect the Tellabs 6310 node, flexible
version, 2U high.
Provide reference information.
Structure of the Manual
Manual structure The manual is structured as follows:
1 Overview on page 15 introduces the Tellabs 6310 node.
2 Installation Information on page 17 describes how to install and con-
nect the Tellabs 6310 node.
3 Reference Information on page 35 gives logistics, technical description
and specification information about the Tellabs 6310 node.
A Packing Instructions on page 71 gives additional information like in-
structions on how to pack modules before shipment.
Abbreviations
Abbreviations used in
this manual
ADM Add/Drop Multiplexer
AGGR Aggregate
AUX Auxiliary Alarm
CID Consecutive Identical Digit
ECC Embedded Communications Channel
EMC Electromagnetic Compatibility
ETSI European Telecommunications Standards Institute
GFP Generic Framing Procedure
ID Identification
IEC International Electrotechnical Commission
IETF The Internet Engineering Task Force community
I/O Input/Output
IP Internet Protocol
ITU-T ITU - Telecommunication Standardisation Sector
12 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
Preface
ITU International Telecommunication Union
LAPS Link Access Procedure - SDH
LCAS Link Capacity Adjustment Scheme
LED Light Emitting Diode
MAC Media Access Control
MDI Media Dependent Interface
MDIX MDI cross-over
MTBF Mean Time Between Failures
MLM Multi Longitudinal Mode Laser
MPLS Multi-Protocol Label Switching
NA Not Applicable
PDH Plesiochronous Digital Hierarchy
PIN P-doped, Intrinsic, N-doped
PPP Point-to-Point Protocol
PRC Primary Reference Clock
RFC Request for Comments
S4 VC-4 path layer
S12 VC-12 path layer
SDH Synchronous Digital Hierarchy
SEC Synchronous Equipment Clock
SFP Small Formfactor Pluggable
SIR Signal / Interference Ratio
SLM Single Longitudinal Mode Laser
SNC/I Inherently monitored Sub-Network Connection protection
SNMP Simple Network Management Protocol
STM Synchronous Transport Module
SW Software
T0 Outgoing SDH timing reference point
T1 Incoming SDH timing reference point
T2 Incoming PDH timing reference point
T3 External 2.048 MHz reference timing source
TCP Transmission Control Protocol
TDEV Time Deviation
TM Terminal Multiplexer
TRIB Tributary
UDP User Datagram Protocol
VC-4 Virtual Container of 4'th order
VC-12 Virtual Container of 1st order
Definition of Terms
System/Network
Element:
A complete functional unit with transport and element management function-
ality, power supply; all mounted in one or more subracks.
Aggr. 1: Direction naming of the aggregate signal of a network element. Aggr.1 is also
named the S1 port.
Aggr. 2: Direction naming of the aggregate signal of a network element. Aggr.2 is also
named the S2 port.
MA322 Rev. F1 13
Tellabs

6310 Edge Node


Flexible Version, 2U High
Preface
References
References to Tellabs
documents
[1] MA327, Tellabs

6300 Managed Transport System, Tellabs

6300 Net-
work Manager, Managing Tellabs

6310/6320 Edge Node, User's Manual


Note: See the product release notes for a list of manuals that are valid for your
current software/hardware version.
14 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
Preface
MA322 Rev. F1 15
Tellabs

6310 Edge Node


Flexible Version, 2U High
1 Overview
1 Overview
In this overview This overview gives a short introduction of the Tellabs 6310 node.
1.1 Introduction on page 15
1.2 Layout on page 16
1.1 Introduction
Product relationship The Tellabs 6310 node is part of the Tellabs product range for access and re-
gional telecommunication transmission networks based on the standards and
recommendations on SDH from ETSI and ITU.
Short product description The Tellabs 6310 node is a product where SDH Add/Drop Multiplexers
(ADM1/4) and Terminal Multiplexers (TM1) are implemented in a stand
alone unit. In addition to the 2 Mbit/s tributary interfaces available, the fol-
lowing interfaces are possible options:
34 Mbit/s
45 Mbit/s
10/100 Mbit/s Ethernet
1 Gbit/s Ethernet
Protection The possible protection schemes in the network includes SNC Protection.
Management Management of the Tellabs 6310 node can be performed from a local craft ter-
minal, or remotely from a network element manager or a network manage-
ment system (Tellabs

6300 network manager).


16 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
1 Overview
1.2 Layout
Variants Two different front layouts of the Tellabs 6310 node reflect the two different
connector types used for either the 120 ohm 2 Mbit/s interfaces or the 75 ohm
2 Mbit/s interfaces.
Layout of unit with
120 ohm 2 Mbit/s
interfaces
The figure below shows the Tellabs 6310 node with RJ-45 connectors for the
120 , 2Mbit/s interfaces.
Layout of unit with
75 ohm 2 Mbit/s
interfaces
The figure below shows the Tellabs 6310 node with coax connectors for the
75 , 2Mbit/s interfaces.
MA322 Rev. F1 17
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
2 Installation Information
Overview This installation information describes the installation and cabling of the Tel-
labs 6310 node. It comprises the following parts:
2.1 Optical Safety Considerations on page 17
2.2 Labels on Equipment on page 18
2.3 Physical Placement on page 18
2.4 Installing the Tellabs 6310 Node on page 19
2.5 Replacing the Air Filter on page 30
2.6 Replacing the Tributary Module on page 31
2.1 Optical Safety Considerations
General The Tellabs 6310 node is classified as a Class 1 laser product in accordance
with IEC 825, that is exposure to hazardous laser radiation is impossible dur-
ing normal operation and maintenance. When the system has been installed,
the laser radiation is effectively enclosed in the optical fiber path between op-
tical modules at each end.
In case of an interruption of the optical STM-1/STM-4 fiber path by accident
(for instance cable rupture) an automatic safety mechanism will result in a pe-
riodic shutdown of the transmitter laser. Hence, the laser radiation from any
fiber end is restricted to a 2 second period, which is repeated every 70 seconds.
With less than 0 dBm (L-1.1 and L-1.2) or 2 dBm (L-4.1 and L-4.2) radiated op-
tical power during the 2 second period, the time averaged power is less than
-13 dBm, which is harmless at relevant wavelengths.
IEC825 classification
limits of optical power
radiated from single
mode fiber end
Exposure to laser radiation risked during service or installation can be hazard-
ous in case of double fault conditions.
Laser warning The illustration describes laser safety rules.
Classification 1310 nm 1550 nm
Class 1 Regarded as safe for all
viewing conditions
+10.0 dBm +10.0 dBm
18 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
2.2 Labels on Equipment
Identification labels The Tellabs 6310 node is provided with identification labels at the front and
bottom of the enclosure.
2.3 Physical Placement
Placement rules The Tellabs 6310 node is designed to operate in a typical commercial environ-
ment. Please observe the following rules:
In case of AC powering, use a grounded, three pronged power outlet ap-
proved by the electrical code of the region.
Location must be clean, dust free and well ventilated.
Do not cover ventilation holes.
MA322 Rev. F1 19
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
2.4 Installing the Tellabs 6310 Node
To install the Tellabs
6310 node
To complete the installation of the Tellabs 6310 node, the following steps must
be performed.
Step Action
1 Mount the Tellabs 6310 node in the rack as described in
2.4.1 Mounting the Tellabs 6310 Node in the Rack on page 20.
Note: If you wish to use the Tellabs 6310 node outside a rack, you can
provide the housing with four rubber feet instead of the brackets and
place the Tellabs 6310 node at your preferred location. In that situa-
tion this step can be omitted.
2 Connect the cables as described in 2.4.2 Connecting the Cables to the
Tellabs 6310 Node on page 23.
3 Configure the Tellabs 6310 node by following the instructions in the
Tellabs 6300 manager manuals [1]. See also 2.4.3 Identification Set-
tings on page 29.
20 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
2.4.1 Mounting the Tellabs 6310 Node in the Rack
To mount the Tellabs
6310 node into a rack
Please follow the instructions below.
Step Action
1 If the rack system provides sufficient depth, then mount the left and
right side brackets as shown below, each with 2 screws (M4 x 8) and
washers.
The same brackets are used for both 19 inch rack and ETSI racks, but
mounted differently.
MA322 Rev. F1 21
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
2 If the rack system has limited depth, then mount the left and right
side brackets as shown below, each with 2 screws (M4 x 8) and wash-
ers.
The same brackets are used for both 19 inch rack and ETSI racks, but
mounted differently.
3 Insert the nuts including clips in the holes corresponding to the de-
sired rack position of the Tellabs 6310 node.
Step Action
22 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
4 Mount the Tellabs 6310 node in the desired rack position. Fasten it
with four M6 screws including protection rings.
Note: The screw at the top left of the unit must be mounted without
a protection ring, to ensure firm contact to safety earth.
Step Action
MA322 Rev. F1 23
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
2.4.2 Connecting the Cables to the Tellabs 6310 Node
Cable types Shielded cables are required on all interfaces except DC and AC power. This
in order to ensure compliance with the EMC directive. It is the responsibility
of the user to provide and use shielded cables.
Available cables The cables available for the Tellabs 6310 node are listed in 3.2 Logistics on
page 36.
To connect the transport
and management cables
The following procedure describes how to connect the transport and manage-
ment cables to the unit. Some steps might not be relevant for your specific
unit. In these situations you just go to the next step.
Warning: Care must be taken to protect optical connectors against dust, touch-
ing and all contact with other objects.
Note: All disconnected optical connectors must be covered with dust protect-
ing caps. Do not remove these caps until immediately before mounting.
Note: If it is difficult to connect or remove the coaxial cables of the 75 inter-
faces, then use an extraction tool (item number TOOL-H030).
Step Action
1 Connect the optical cables for the aggregate interfaces (MAIN S1-S2).
Note: Please observe the minimum bending radius of the optical fiber
(35 mm), to avoid damage to the fibers.
24 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
2 Connect the optical cables for the optical Ethernet tributary interfac-
es (TRIB S1-S2). Use connector S1 for Ethernet channel 5 and connec-
tor S2 for Ethernet channel 6.
Note: Please observe the minimum bending radius of the optical fiber
(35 mm), to avoid damage to the fibers.
Note: Use 50/125m multi mode fiber cables for optical Ethernet in-
terfaces unless you have the 1000BaseLX interface option. For this you
must use single mode fiber.
3 Connect the cables for the electrical 10/100 Mbit/s Ethernet interfac-
es, channel 1-4 (D1-D4).
4 Connect the cables for the 34/45 Mbit/s interfaces (P1-P2-P3).
Step Action
MA322 Rev. F1 25
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
5 Connect the cables for the 2 Mbit/s interfaces (1-21).
6 Connect the cables for the synchronization interface (SYNC)
Step Action
26 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
7 Connect the Ethernet cable (MGT) for management of the Tellabs
6310 node.
8 Connect a PC running the Craft Terminal program to the MGT/CT
connector at the front of the unit for local management of the Tellabs
6310 node.
9 Connect alarm cable to the ALARM connector at the rear of the unit.
Step Action
MA322 Rev. F1 27
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
To connect the DC
power cables
The following procedure describes how to connect the DC power cables to the
unit. This procedure can be omitted if only AC power is used.
10 Connect DTMF-EOW cable to the EOW connector at the rear of the
unit.
11 Connect user channel cables to the USER1/2 connectors at the rear of
the unit.
Step Action
Step Action
1 Connect an earthing cable to the earthing stud.
28 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
To connect the AC
power cable
The following procedure describes how to connect the AC power cable to the
unit. This procedure can be omitted if only DC power is used.
Warning Please note the following warning.
2 Connect the power supply to the DC input plug (3 pole Sub-D con-
nector) at the rear of the unit.
Step Action
Step Action
1 Connect AC power cable to the mains connector.
Note: The AC power cable is not supplied with the Tellabs 6310 node.
2 Engage the locking mechanism.
MA322 Rev. F1 29
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
Caution Please note the following caution.
The equipment has been designed for connection to an IT power system.
2.4.3 Identification Settings
ID values The purpose of the ID settings is to obtain information about the addresses for
installed modules when using the management system. The ID settings for the
Tellabs 6310 node are fixed and can therefore not be changed. The settings are
as follows:
ID Value
Rack 15
Subrack 7
Slot 3 (Main module)
4 (Trib module)
30 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
2.5 Replacing the Air Filter
To replace the filter Follow the procedure below when you need to replace the air filter in the Tel-
labs 6310 node.
Step Action
1 Pull out the used filter.
Use the strap on the front of the filter.
2 Install the new filter (item number NS-0286).
Note: It is important that the filter is turned correctly before it is in-
serted in to the unit. The filter side with the grid must face towards
the center of the unit.
MA322 Rev. F1 31
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
2.6 Replacing the Tributary Module
To replace the tributary
module
Please follow the procedure below if you have to replace the tributary module
in the Tellabs 6310 node.
Note: This procedure only applies to tributary modules with electrical inter-
faces. It is recommended to send the whole unit to Tellabs if a module
with optical interfaces has to be replaced.
Note: Performing this procedure will interrupt connections to EOW, user
channels and alarm connectors on the rear plate.
Note: To avoid damage on components sensitive to static electricity, use an
antistatic bracelet connected to the chassis of the Tellabs 6310 node.
Step Action
1 Remove the four screws fastening the rear plate to the unit.
2 Pull the rear plate off. Do it in a straight movement.
The straight movement ensures that the connector between the fan
module and the rear plate will not be damaged.
Note: Make sure to save the two EMC gaskets from the rear plate and
chassis.
32 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
3 Push the release mechanism on the tributary module and pull out
the tributary module using the two levers simultaneously.
Note: Look out for the optical fibers on the ADM/TM module.
4 Insert the new tributary module. For the last movement use the two
levers simultaneously.
Note: Look out for the optical fibers on the ADM/TM module.
Note: If you are going to install a TEX31 or TEXDS31 module, then
perform To verify the switches on the TEX31/TEXDS31 module on
page 34 before you install the module.
5 Reinstall the EMC gaskets on the rear plate and chassis.
Note: The springs on the gaskets must be positioned as shown.
Step Action
MA322 Rev. F1 33
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
6 Reinstall the rear plate.
Note: Ensure that the connector on the rear plate fits correctly into the
connector on the fan module.
7 Fasten the rear plate with the four screws.
8 Connect cables to the Tellabs 6310 node as described in
2.4.2 Connecting the Cables to the Tellabs 6310 Node on page 23
Step Action
34 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
2 Installation Information
To verify the switches on
the TEX31/TEXDS31
module
Working in the Tellabs 6310 node, the switches on the TEX31/TEXDS31 mod-
ule must be placed as described in the procedure below.
Step Action
1 If not already so, then set the switches in the positions shown on the
figure below.
MA322 Rev. F1 35
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3 Reference Information
Overview The reference information includes information about item numbers, func-
tional description and specifications of the Tellabs 6310 node.
3.1 Front Layout on page 35
3.2 Logistics on page 36
3.3 LEDs and Connectors on page 38
3.4 Functional Description on page 40
3.5 Specifications on page 43
3.1 Front Layout
Tellabs 6310 node front
layout
The figure below shows the Tellabs 6310 node with RJ-45 connectors for the
120 , 2Mbit/s interfaces and the Tellabs 6310 node with coax connectors for
the 75 , 2Mbit/s interfaces.
36 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.2 Logistics
Tellabs 6310 node item
numbers
The Tellabs 6310 node can be ordered in the following versions. The structure
of the item number can be expressed as CU369#-####-#.
Cables The table lists the cables available for the Tellabs 6310 node.
CU369#- ####-# Description
CU3690- AC+DC version
CU3691- DC version
1###-# TM1, 21 x 2 Mbit/s, 75R
2###-# ADM1, 21 x 2 Mbit/s, 75R
4###-# ADM4, 21 x 2 Mbit/s, 75R
5###-# TM1, 21 x 2 Mbit/s, 120R
6###-# ADM1, 21 x 2 Mbit/s, 120R
8###-# ADM4, 21 x 2 Mbit/s, 120R
#1##-# S-x.1 optical aggregate
#2##-# L-x.1 optical aggregate
#3##-# L-x.2 optical aggregate
##01-A 1 x 34 Mbit/s (TEX31)
##02-A 1 x 45 Mbit/s (TEXDS31)
##09-A 4 x 10/100 BaseT Ethernet (ETEX4)
##10-A 4 x 10/100 BaseT and 2 x 100 BaseFX
Ethernet (ETEX8M)
##11-A 3 x 34 Mbit/s (TEX33)
##12-A 3 x 45 Mbit/s (TEXDS33)
##19-B 4 x 10/100 BaseT and 2 x 100 BaseFX
Ethernet, with L2 switch (ETEX8S)
##20-A 2 x 1000 BaseSX Ethernet, with L2
switch (ETEX2S)
##21-A 2 x 1000 BaseLX Ethernet, with L2
switch (ETEX2S)
Number Description
Optical single mode fiber cables, two fibers in one cable
W-OF203/05.0 2xLC to 2xLC single mode fiber cable, 5 m
W-OF203/10.0 2xLC to 2xLC single mode fiber cable, 10 m
MA322 Rev. F1 37
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Miscellaneous items The table lists miscellaneous items available for the Tellabs 6310 node.
W-OF203/20.0 2xLC to 2xLC single mode fiber cable, 20 m
W-OF204/05.0 2xLC to 2xFC/PC single mode fiber cable, 5 m
W-OF204/10.0 2xLC to 2xFC/PC single mode fiber cable, 10 m
W-OF204/20.0 2xLC to 2xFC/PC single mode fiber cable, 20 m
W-OF205/05.0 2xLC to 2xSC single mode fiber cable, 5 m
W-OF205/10.0 2xLC to 2xSC single mode fiber cable, 10 m
W-OF205/20.0 2xLC to 2xSC single mode fiber cable, 20 m
W-OF206/05.0 2xLC to 2xDIN single mode fiber cable, 5 m
W-OF206/10.0 2xLC to 2xDIN single mode fiber cable, 10 m
W-OF206/20.0 2xLC to 2xDIN single mode fiber cable, 20 m
Optical multi mode fiber cables, two fibers in one cable
W-OF207/05.0 2xLC to 2xLC multi mode fiber cable, 5 m
W-OF207/10.0 2xLC to 2xLC multi mode fiber cable, 10 m
W-OF207/20.0 2xLC to 2xLC multi mode fiber cable, 20 m
Electrical cables
461-0021-003 Shielded twisted pair, cross-over, RJ-45 to RJ-45, 5 m,
Crossed trib. cable for 120 interface.
WK-453B-03.0-01 Coaxial cable, 1.0/2.3 right angle to BNC right angle,
3 m, Trib. cable for 75 interface.
WK-480X-03.0-01 Craft interface cable, RJ-45 to 9 pole sub-D, 3 m, Con-
nection to the front of the unit.
W-A-4-4712 Ethernet cable. BNC male connector to BNC male
connector, 3 m.
WK-061A Ethernet termination set. The set includes a BNC
50 T adapter (Male-Female-Female) and two 50
BNC terminations.
WK-454Z-02.6-01 DC power input cable, open ended to 3 pole sub-D,
2.6 m.
Number Description
Number Description
NS-0286 Air filter.
38 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.3 LEDs and Connectors
Front The figure below shows the LEDs and connectors on the front of the Tellabs
6310 node.
The function of the LEDs and connectors are described in the table below.
TOOL-H030 Extraction tool for coaxial cable.
Number Description
LED/Connector Description
Power Green LED
ON during normal operation
OFF in case +/-5V exceeds lower limits
Alarm Red LED
OFF during normal operation
IN S1 OUT MAIN STM-1/4 optical S1 interface for ADM and TM
module.
IN S2 OUT MAIN STM-1/4 optical S2 interface for ADM module.
MA322 Rev. F1 39
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Rear The figure below shows the connectors on the rear of the Tellabs 6310 node.
The function of the connectors are described in the table below.
IN S1 OUT TRIB Optical 100 Mbit/s Ethernet interface for
ETEX8M/S and 1 Gbit/s Ethernet interface for
ETEX2S, channel 5.
IN S2 OUT TRIB Optical 100 Mbit/s Ethernet interface for
ETEX8M/S and 1 Gbit/s Ethernet interface for
ETEX2S, channel 6.
S1 -
S2 -
P1 34/45 Mbit/s tributary interface for TEX31,
TEX33, TEXDS31 and TEXDS33.
P2, P3 34/45 Mbit/s tributary interface for TEX33 and
TEXDS33.
D1-D4 Electrical 10/100 Mbit/s Ethernet interfaces for
ETEX4 and ETEX8M/S, channel 1-4.
1-21 2 Mbit/s tributary interfaces
SYNC 2 MHz synchronization input/output
MGT Ethernet interface, 10 Base 2
TRIB MGT TRIB module serial management interface
MGT/CT Craft terminal interface
LED/Connector Description
Connector Description
UCH1 User channels, ADM/TM module V.11 and V.28
UCH2 User channels, ADM/TM module V.11 and TRIB
module V.28
EOW Engineering ordering wire (DTMF-EOW), ADM/
TM module
ALARM System alarm
3 pole Sub-D power -48 V power input
40 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.4 Functional Description
Housing The Tellabs 6310 node is housed in a 2 U high subrack. The supplied flanges
can be mounted to adapt to either 19 inch or ETSI wide racks. In addition it is
possible to place the housing on a desk using the supplied rubber feet.
All necessary connections are made directly to the connectors at the front and
rear of the unit.
Block diagram The figure shows a simplified block diagram of the Tellabs 6310 node. The
tributary interfaces available depends on the specific variant of the Tellabs
6310 node.
Earthing stud
3 pole power AC power connector with locking mechanism
and with primary fuses.
Connector Description
MA322 Rev. F1 41
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Master controller Internally the Tellabs 6310 node is managed by means of a master controller
on the ADM/TM module.
The master controller contains a non-volatile memory for the application SW
of the network element. This memory can contain two versions of the SW and
download of new SW while in service is possible.
Protection The ADM can perform 1+1 SNC/I protection of the VC-12 signals.
SNC/I protection (Inherently monitored Sub-Network Connection protec-
tion) is based upon Loss Of Pointer and AIS detection in the S4/S12 function.
Synchronization sources The source for the internal timing reference T0 is derived among:
Two 2.048 Mbit/s Tributary inputs (T2 references), freely selectable
STM-1/4 inputs (T1 references)
One external 2.048 MHz reference timing source (T3 reference).
Internal oscillator
Management Interface
types
Management/supervision of the Tellabs 6310 node is possible via three types
of interfaces:
Craft Terminal interface
Ethernet interface
Embedded Communications Channel (ECC) of STM-1/4 line.
The ECC may be transferred in DCCR or DCCM bytes of the STM-1/4 line
overhead or in selectable VC-12.
Management software The Tellabs 6310 node can be managed by the Tellabs 6300 manager software.
The purpose of the management software is to monitor and control the behav-
ior of the Tellabs 6310 node and the associated transport signals and to man-
age software downloading and upgrading. Proper installation of embedded
software is required to enable the unit to operate.
The system is controlled via the Craft Terminal Interface, the Ethernet inter-
face or via the STM-1/4 embedded control channels.
For detailed description of the mentioned management software please refer
to the respective user manuals [1].
Fans The Tellabs 6310 node is cooled by two fans running simultaneously in the
unit.
Fan speed can have three levels and is controlled by a temperature monitoring
circuit on the power supply. If a fan fails then the other fan will be turned to
full speed. One fan is adequate to keep the Tellabs 6310 node within normal
operating temperature conditions.
Tachometer signals from the fans are monitored and fan failures are signalled
to the AUX1 and AUX2 alarm ports on the MAIN module.
Power feeds and monitor signals are independent for the two fans.
42 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Power supply
configurations
The Tellabs 6310 node is powered from nominal 115/230 VAC and/or dual -
48 VDC. The customer can choose between the following configurations:
AC input only. This may be the case in many non telecommunications of-
fices. If back-up of the supply is required, an uninterruptable power
source (UPS) can be inserted between the mains and the Tellabs 6310
node.
Combined AC and DC powering. AC input as main supply and one of the
DC inputs as protection supply (in case the AC supply fails)
DC input only. One of the DC inputs as main power supply input and the
other as protection supply (in case the main supply fails).
Power system
description
The following figure shows the power system on the Tellabs 6310 node. The
115/230VAC input has priority over the -48 VDC inputs, that is, when the AC
power is present, this input will provide power. In case the AC power is not
present, the DC input with the most negative voltage will provide power.
RTN (GND) of the DC/DC converter has a DC path to the Tellabs 6310 node
enclosure/signal ground. RTN of the -48 VDC supply input is not connected
to enclosure/signal ground.
The input and output of the AC/DC and DC/DC converter are galvanically
isolated.
The equipment has been designed for connection to an IT power system.
The 115/230VAC input is double fused with a fuse on both phase and neutral.
It is possible to secure the AC power cable with a locking mechanism.
A green LED at the front of the Tellabs 6310 node indicates, that the +/-5V
supply voltage for the ADM/TM module is within range.
MA322 Rev. F1 43
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.5 Specifications
Overview The specifications for the Tellabs 6310 node are described in:
3.5.1 STM-4 and STM-1 Optical Interfaces on page 43
3.5.2 PDH Electrical Interfaces on page 45
3.5.3 Ethernet Interfaces on page 49
3.5.4 Synchronization Interface on page 52
3.5.5 Management Interfaces on page 55
3.5.6 Power on page 58
3.5.7 Mechanical on page 59
3.5.8 Environmental on page 62
3.5.9 EMC Conditions on page 64
3.5.10 Safety on page 66
3.5.11 R&TTE on page 67
3.5.12 MTBF on page 67
3.5.1 STM-4 and STM-1 Optical Interfaces
Optical STM-4 port The following table shows the optical STM-4 parameters.
Note: "na" in a cell of the table means "not applicable".
Parameter Value Unit
Class S-4.1 L-4.1 L-4.2
Specifications accord-
ing to
G.957
Nominal Bit Rate 622,080 20 ppm kbit/s
Transmitter at reference point S
Source Type MLM SLM SLM
Wavelength range 1274-1356 1280-1335 1480-1580 nm
- max. RMS width 2.5 na na nm
- max. -20 dB width na 1 1 nm
- min. SMSR na 30 30 dB
Mean launched power
range
-15 to -8 -3 to +2 -3 to +2 dBm
Min. extinction ratio 8.2 10 10 dB
Pulse Mask According to Fig.2/G.957
Jitter Generation G.813 option 1
44 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Optical STM-1 port The following table shows the optical STM-1 parameters.
Note: "na" in a cell of the table means "not applicable".
Optical Path between S and R
Attenuation range 0 to 12 10 to 24 10 to 24 dB
Maximum dispersion 74 na 2200 ps/nm
Min. opt. return loss of
cable plant at S (incl.
conn.)
na 20 24 dB
Max. discrete reflec-
tance between S and R
na -25 -27 dB
Receiver at reference point R
Receiver type PIN PIN PIN
Minimum point R sen-
sitivity at BER = 10
-10
-28 -28 -28 dBm
Min. overload -8 -8 -8 dBm
Max. optical path pen-
alty
1 1 1 dB
Max. receiver reflec-
tance measured at R
na -14 -27 dB
Jitter Tolerance G.825
CID Immunity According to: App. 1/G.958
Parameter Value Unit
Class S-4.1 L-4.1 L-4.2
Parameter Value Unit
Class S-1.1 L-1.1 L-1.2
Specifications accord-
ing to
G.957
Nominal Bit Rate 155,520 20 ppm kbit/s
Transmitter at reference point S
Source Type MLM MLM SLM
Wavelength range 1261-1360 1263-1360 1480-1580 nm
- max. RMS width 7.7 3 na nm
- max. -20 dB width na na 1 nm
- min. SMSR na na 30 dB
MA322 Rev. F1 45
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.5.2 PDH Electrical Interfaces
45 Mbit/s Input port The following table shows the specifications for the electrical input ports at
reference point ER.
Mean launched power
range
-15 to -8 -5 to 0 -5 to 0 dBm
Min. extinction ratio 8.2 10 10 dB
Pulse Mask According to Fig.2/G.957
Jitter Generation G.813 option 1
Optical Path between S and R
Attenuation range 0 to 12 10 to 28 10 to 28 dB
Maximum dispersion 96 246 na ps/nm
Min. opt. return loss of
cable plant at S (incl.
conn.)
na na 20 dB
Max. discrete reflec-
tance between S and R
na na -25 dB
Receiver at reference point R
Receiver type PIN PIN PIN
Minimum point R sen-
sitivity at BER = 10
-10
-28 -34 -34 dBm
Min. overload -8 -10 -10 dBm
Max. optical path pen-
alty
1 1 1 dB
Max. receiver reflec-
tance measured at R
na na -25 dB
Jitter Tolerance G.825
CID Immunity According to: App. 1/G.958
Parameter Value Unit
Class S-1.1 L-1.1 L-1.2
Parameter Value for 45 Mbit/s tributary input ports
Interface Coaxial pair - 75 Ohm
Bit rate 44.736 Mbit/s +/- 20 ppm
Code B3ZS
Jitter and wander toler-
ance
Table 2 / G.824, TR TSY 000499 Cat. 2
46 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
45 Mbit/s output port The following table shows the specifications for the electrical output ports at
reference point ES.
34 Mbit/s Input port The following table shows the specifications for the electrical input ports at
reference point ER.
Over voltage protection ITU-T K.41
f attenuation (Cable: 0-135 meters WECO 728A coaxial or
equivalent)
Grounding of outer
conductor / screen
Only connection of outer conductor to ground is
supported.
Parameter Value for 45 Mbit/s tributary input ports
Parameter Value for 45 Mbit/s tributary output ports
Interface Coaxial pair - 75 Ohm
Bit rate 44.736 Mbit/s +/- 20 ppm
Code B3ZS
Jitter generation ANSI T1.105 / T1.102
Jitter generation (Map-
ping A0)
10 Hz - 400 kHz: 0.4 UI
pp
30 kHz - 400 kHz: 0.1 UI
PP
Jitter generation (Com-
bined, pointer se-
quence)
A1: A0 + 0.3 UI
pp
A2,A5: 1.3 UI
PP
A3: 1.2 UI
PP
A4: 1.0 UI
PP
Over voltage protection ITU-T K.41
Peak voltage mark 0.36 to 0.85 V
P

Pulse shape Figure 4 / ANSI T1.102
Parameter Value for 34 Mbit/s tributary input ports
Interface Coaxial pair - 75 Ohm
Bit rate 34.368 Mbit/s +/- 20 ppm
Code HDB3
Jitter and wander toler-
ance
Figure 15 /G.823
Over voltage protection ITU-T K.41
MA322 Rev. F1 47
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
34 Mbit/s output port The following table shows the specifications for the electrical output ports at
reference point ES.
2 Mbit/s Input port The following table shows the specifications for the electrical input ports at
reference point ER.
Return loss >12 dB @ 860-1720 kHz
>18 dB @ 1720-34368 kHz
>14 dB @ 34368-51550 kHz
f attenuation 12 dB @ 17.184 MHz
SIR 20 dB
Grounding of outer
conductor / screen
Only connection of outer conductor to ground is
supported.
Parameter Value for 34 Mbit/s tributary input ports
Parameter Value for 34 Mbit/s tributary output ports
Interface Coaxial pair - 75 Ohm
Bit rate 34.368 Mbit/s +/- 20 ppm
Code HDB3
Jitter generation (Map-
ping)
100 Hz - 800 kHz: 0.25 UI
pp
10 kHz - 800 kHz: 0.075 UI
PP
Jitter generation (Com-
bined, pointer sequence
B-D-E)
100 Hz - 800 kHz: 0.4 UI
pp
10 kHz - 800 kHz: 0.075 UI
PP
Jitter generation (Com-
bined, pointer sequence
C)
100 Hz - 800 kHz: 0.75 UI
pp
10 kHz - 800 kHz: 0.075 UI
PP
Over voltage protection ITU-T K.41
Return loss 6 dB @ 860-1720 kHz
8 dB @ 1720-51550 kHz
Peak voltage mark 1.00 V
P
+/- 10%
Pulse shape Table 8 /G.703, Figure 17 /G.703
Parameter Value for 2 Mbit/s tributary input ports
Interface Coaxial pair - 75 Ohm
Symmetrical pair - 120 Ohm
Bit rate 2.048 Mbit/s +/- 50 ppm
Code HDB3
48 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
2 Mbit/s output port The following table shows the specifications for the electrical output ports at
reference point ES.
Jitter and wander toler-
ance
Figure 13 /G.823
Over voltage protection ITU-T K.41
Return loss >12 dB @ 51-102 kHz
>18 dB @ 102-2048 kHz
>14 dB @ 2048-3072 kHz
f attenuation 6 dB @ 1.024 MHz
SIR 18 dB
Grounding of outer
conductor / screen
Only connection of outer conductor to ground is
supported.
Parameter Value for 2 Mbit/s tributary input ports
Parameter Value for 2 Mbit/s tributary output ports
Interface Coaxial pair - 75 Ohm
Symmetrical pair - 120 Ohm
Bit rate 2.048 Mbit/s +/- 50 ppm
Code HDB3
Jitter generation (Map-
ping)
20 Hz - 100 kHz: 0.25 UI
pp
700 Hz - 100 kHz: 0.075 UI
PP
Jitter generation (Com-
bined)
20 Hz - 100 kHz: 0.4 UI
pp
700 Hz - 100 kHz: 0.075 UI
PP
Over voltage protection ITU-T K.41
Return loss 0 dB (Coaxial pair - 75 Ohm)
>10dB 50-3000 kHz (Symmetrical pair - 120
Ohm)
Peak voltage mark 2.37 V
P
+/- 10% (Coaxial pair - 75 Ohm)
3.00 V
P
+/- 10% (Symmetrical pair - 120 Ohm)
Pulse shape Table 6 /G.703, Figure 15 /G.703
MA322 Rev. F1 49
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.5.3 Ethernet Interfaces
Electrical ports for
ETEX4 option
The following table shows the specifications for the ETEX4 Ethernet ports.
Electrical ports for
ETEX8M/S option
The following table shows the specifications for the electrical ETEX8M/S
Ethernet ports.
Auto-negotiation The electrical Ethernet interface automatically distinguishes whether to oper-
ate at 10 or 100 Mbit/s.
Optical ports for
ETEX8M/S option
The following table shows the specifications for the optical ETEX8M/S Ether-
net ports.
Parameter Value for electrical Ethernet ports
Interface 10 BaseT: 10 Mbit/s full duplex STP CAT3/5 ca-
ble
100 BaseTX: 100 Mbit/s full duplex STP CAT5 ca-
ble
Auto-negotiation
Bit rate 10 BaseT: 10 Mbit/s 100 ppm
100 BaseTX: 100 Mbit/s 100 ppm
Standards IEEE 802.3
Parameter Value for electrical Ethernet ports
Interface 10 BaseT: 10 Mbit/s full duplex STP CAT3/5 ca-
ble
100 BaseTX: 100 Mbit/s full duplex STP CAT5 ca-
ble
Full auto-negotiation Auto MDI/MDIX
Bit rate 10 BaseT: 10 Mbit/s 100 ppm
100 BaseTX: 100 Mbit/s 100 ppm
Standards IEEE 802.3
Parameter Value for optical Ethernet ports
Interface 100 BaseFX: 100 Mbit/s full duplex, optical 2 km
Bit rate 100 Mbit/s 100 ppm
Standards IEEE 802.3
Fiber cable 50/125 m multi mode
50 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
100BASE-FX ports The 100BASE-FX interfaces are according to ANSI INCITS 237-1955.
Optical ports for ETEX2S
option
The following table shows the specifications for the optical ETEX2S Ethernet
ports.
Parameter Minimum Maximum Unit
Transmitter
Center wavelength (, range) 1270 1380 nm
Spectrum FWHM na 250 nm
Average power -22.0 -14.0 dBm
T
rise
(10% - 90%) na 4.0 ns
T
fall
(90% - 10%) na 4.0 ns
Duty cycle distortion, peak-peak 0.0 1.0 ns
Data dependent jitter, peak-peak 0.0 0.6 ns
Random jitter, peak-peak 0.0 0.76 ns
Extinction ratio (min) 0.0 10.0 %
Receiver
Center wavelength (, range) 1270 1380 nm
Average power -29.0 -14.0 dBm
T
rise
(10% - 90%) na 4.5 ns
T
fall
(90% - 10%) na 4.5 ns
Duty cycle distortion, peak-peak 0.0 1.0 ns
Data dependent jitter, peak-peak 0.0 0.6 ns
Random jitter, peak-peak 0.0 0.76 ns
Parameter Value for optical Ethernet ports
Interface 1000 BaseSX: 1 Gbit/s full duplex, optical
1000 BaseLX: 1 Gbit/s full duplex, optical
Bit rate 1 Gbit/s 100 ppm
Standards IEEE 802.3
Fiber cable 1000 BaseSX: 50/125 m multi mode
1000 BaseLX: Single mode
MA322 Rev. F1 51
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
1000BASE-SX ports The 1000BASE-SX interfaces are according to IEEE802.3.
1000BASE-LX ports The 1000BASE-LX interfaces are according to IEEE802.3.
Parameter Value Unit
Fiber type 50 m multi mode
Transmitter
Transmitter type Shortwave laser
Signalling speed (range) 1.25 100 ppm Gbit/s
Wavelength (, range) 770 to 860 nm
T
rise
/T
fall
(max: 20% - 80%, > 830 nm) 0.26 ns
T
rise
/T
fall
(max: 20% - 80%, < 830 nm) 0.21 ns
RMS spectral width (max) 0.85 nm
Average launch power (max) 0 dBm
Average launch power (min) -9.5 dBm
Average launch power of OFF transmit-
ter (max)
-30 dBm
Extinction ratio (min) 9 dB
RIN (max) -117 dB/Hz
Coupled Power Ratio (CPR) (min) 9 < CPR dB
Receiver
Signalling speed (range) 1.25 100 ppm Gbit/s
Wavelength (, range) 770 to 860 nm
Average receive power (max) 0 dBm
Receive sensitivity -17 dBm
Return loss (min) 12 dB
Stressed receive sensitivity -13.5 dBm
Vertical eye-closure penalty 2.20 dB
Receive electrical 3 dB upper cutoff fre-
quency (max)
1500 MHz
Parameter Value Unit
Fiber type 10 m single mode
Transmitter
Transmitter type Longwave laser
52 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.5.4 Synchronization Interface
External 2 MHz
reference timing source
The following table shows the specifications for the external 2 MHz synchro-
nization input at reference point ER.
Signalling speed (range) 1.25 100 ppm Gbit/s
Wavelength (, range) 1270 to 1355 nm
T
rise
/T
fall
(max: 20% - 80% response
time)
0.26 ns
RMS spectral width (max) 4 nm
Average launch power (max) -3 dBm
Average launch power (min) -11.0 dBm
Average launch power of OFF transmit-
ter (max)
-30 dBm
Extinction ratio (min) 9 dB
RIN (max) -120 dB/Hz
Coupled Power Ratio (CPR) (min) n/a dB
Receiver
Signalling speed (range) 1.25 100 ppm Gbit/s
Wavelength (, range) 1270 to 1355 nm
Average receive power (max) -3 dBm
Receive sensitivity -19 dBm
Return loss (min) 12 dB
Stressed receive sensitivity -14.4 dBm
Vertical eye-closure penalty 2.60 dB
Receive electrical 3 dB upper cutoff fre-
quency
max. 1500 MHz
Parameter Value Unit
Parameter Reference Value for 2 MHz synchronization input port
Input imped-
ance (75 ohm
unit)
G.703 75 Ohm
High impedance
Input imped-
ance (120
ohm unit)
G.703 120 Ohm
High impedance (>1.6 kOhm with par-
allel capacity < 60 pF)
Frequency 2.048 MHz +/- 20 ppm (as output)
MA322 Rev. F1 53
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
2 MHz output ports The following table shows the specifications for the external 2 MHz synchro-
nization output at reference point ES.
Synchronization function
in locked mode
The following table describes the specifications for the synchronization func-
tion in locked mode.
Jitter and
Wander toler-
ance
EN 300 462-5 Figure 2 and 3
Over voltage
protection
G.703 ITU-T K.41
Return loss G.703 >15 dB @ 2.048 MHz
f attenuation G.703 6 dB @ 2.048 MHz
Grounding of
outer conduc-
tor or screen
G.703 Always connected to ground
Parameter Reference Value for 2 MHz synchronization input port
Parameter Reference Value for 2 MHz synchronization output port
Frequency 2.048 MHz +/- 20 ppm
Mask Figure 21/
G.703
FTZ TL 5805-
3170
1.5 - 3 V
PP
(Coaxial pair - 75 Ohm)
2.4 - 3.6 V
PP
(Symmetrical pair - 120
Ohm)
Jitter
Wander
Table 10/
G.703
Figure 1/EN
300 462-5
0.05 UI
PP
@ 20 Hz - 100 kHz
Over voltage
protection
G.703 ITU-T K.41
Voltage at
squelch
< 40 mV
P
@ 50 kHz to 6.144 MHz
Parameter Reference SETG output
Locking performance
Capture range G.813, EN 300
462-5
minimum +/- 4.6 ppm
Lock range (fre-
quency range
where locked is
maintained)
Tellabs +/- 20ppm
54 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Synchronization function
in holdover mode
The following table describes the specifications for the synchronization func-
tion in holdover mode.
Jitter and Wan-
der tolerance
EN 300 462-5 EN 300 462-5 figure 2 and 5
The maximum permitted peak-to-
peak sinusoidal jitter, when applied
on the synchronization interfaces,
shall not make the SEC loose track-
ing.
Phase stability TDEV MRTIE (ns)
Ideal Operation EN 300 462-5 fig-
ure 1
0.1<S<25s
32[ns]
25<S<100s
0.64xS
0.5
[ns]
100 <S<1000s
6.4[ns]
0.1<S<1s 40ns
1 <S<100s
40xS
0.2
[ns]
100 <S<1000s
25.25xS
0.2
[ns]
Stressed opera-
tion (Phase tran-
sient)
G.813
EN 300 462-5
-
-
According to
chapter 9.1
According to fig-
ure 6
Change of clock
source
EN 300417-1 The change-over of synchronization
from one source to another (each
traceable to the same PRC) shall be
performed so that the resultant fre-
quency/phase change is compliant
with the MRTIE mask (constraint by
disturbances) given in EN 300 462-5.
The transition between synchroniza-
tion sources may introduce a phase
transient which may result in the
generation of AU/TU pointer ad-
justments but should not introduce
bit errors
Jitter
Jitter transfer
function
EN 300 462-5 Gain < 0.1 dB, Clock bandwidth 1 to
10 Hz
Parameter Reference SETG output
Parameter Reference SETG output
Frequency Stability
Memorized frequency
resolution
Tellabs 0.025 ppm
Frequency offset EN 300 462-5 +/- 4.6 ppm end of life
Frequency offset on en-
try into holdover.
implicit G.813, EN 300
462-5
+/- 0.05 ppm
MA322 Rev. F1 55
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Synchronization function
in free-running mode
The following table describes the specifications for the synchronization func-
tion in free-running mode.
3.5.5 Management Interfaces
Management protocol
stack
Specification of the management protocol stack.
Frequency drift over
temperature
EN 300 462-5 +/- 2.0 ppm
Phase stability MRTIE
Long term phase tran-
sient response
EN 300 462-5 figure 7 S>15s: (a
1
+ a
2
)S +
0.5bS
2
+ c [ns]
a
1
=50 ns/s (initial
frequency offset
(0.05ppm)
a
2
=2000 nS/S ac-
counts for tempera-
ture variations
(2ppm)
b=1.16x10
-4
ns/s
2

accounts ageing
(0.01 ppm/day)
c=120ns
Parameter Reference SETG output
Parameter Reference SETG output
Frequency Stability
Frequency offset EN 300 462-5 +/- 4.6 ppm for ap-
proximately 10 years.
A software option will
allow in system recali-
bration.
Craft Terminal In-
terface
Ethernet ECC Channels
Connection type co co/cl co/cl
Layer
Application LMIP (1) LMIP (1) LMIP (1)
Presentation - - -
Session - - -
56 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Note: (1) Proprietary protocol
Note: (2) A limited but compatible version
Ethernet management
protocol stack
Specification of the Ethernet management protocol stack.
Auxiliary alarm I/O's The system is equipped with auxiliary alarms I/O circuits. The following table
depicts the interface specifications for these interfaces.
Transport NTH(1) TP4:
X.224, X.214
(class 4)
(ISO 8073)
TP4:
X.224, X.214
(class 4)
(ISO 8073)
Network - CLNP: ISO 8473
Addr: ISO
8348:AD2
ES-IS: ISO 9542
IS-IS: ISO 10589
(2)
CLNP: ISO 8473
Addr: ISO
8348:AD2
ES-IS: ISO 9542
IS-IS: ISO 10589
(2)
Data link S-link(1) LLC-1
ISO 8802-2 Type
1
Q.921
LAPD
Physical V.28
9600 baud
CSMA/CD
ISO 8802-3
DCC-R, DCC-M,
F2, VC-12
Craft Terminal In-
terface
Ethernet ECC Channels
Craft Terminal Interface Ethernet
Layer
Application SNMP v2c (IETF RFC
3416)
SNMP v2c (IETF RFC
3416)
Presentation - -
Session - -
Transport TCP (IETF RFC 793) or
UDP (IETF RFC 768)
TCP (IETF RFC 793) or
UDP (IETF RFC 768)
Network IP (IETF RFC 791) IP (IETF RFC 791)
Data link PPP over RS-232 Ethernet 10/100-TX
Physical RS-232 Ethernet 10/100-TX
Signal Description Interface
AUX 2-way configurable control
signals
3V CMOS level. Can source
5 mA as output
MA322 Rev. F1 57
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
AUX port configuration To ensure proper operation of Alarm LED and alarm reporting in case of a
cooling fan failure or AUX alarms, the AUX ports must be configured as fol-
lows:
Use the Tellabs 6300 manager to configure the AUX ports and to perform the
alarm configuration of the AUX ports. Please refer to the manual for Tellabs
6300 manager [1].
As an input, the external alarm can be connected to dry contacts and can be set
via the management system to be either open or closed in the alarm state.
Open inputs are pulled high by pull-up resistors on the ADM/TM module.
Monitored parameters. The following parameters are only monitored at the ADM/TM aggregate
port.
AUX number Configure as
AUX0 Alarm Led, output, active high.
AUX1 Cooling Fan #1 failure, input, active high.
AUX2 Cooling Fan #2 failure, input, active high.
AUX3 -48 V input A missing, input, active low.
AUX4 -48 V input B missing, input, active low.
AUX5 - 7 User configurable inputs, user defined polarity.
Signal Description Range
Accura-
cy
Laser power Optical transmitted mean
power
S-1.1: -20 to -5 dBm 3 dB
L-1.2: -10 to +5
dBm
Optical in-
put power
Received optical mean pow-
er
S-1.1: -28 to -5 dBm 3 dB
L-1.2: -37 to -1 dBm
Laser bias Temperature compensated
bias current relative to initial
factory value
25 to 200% 30%
Laser Tem-
perature
Temperature of the laser (for
instance used for calculation
of the relative bias current).
0 to +90 C 6 C
58 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.5.6 Power
AC input The table lists the AC power specifications.
Secondary supply Dual DC supply. One supply can be used as protection supply for the other.
Tertiary supply The table list the system internal power specifications.
Parameter Value
Nominal Voltage 115 or 230 VAC
Input Voltage 96 to 264 VAC
Input Frequency 47 to 63 Hz
Fuse 2 x T3.15A250V
Power consumption max. 75 W
Parameter Value
Nominal voltage -48 V
Operating voltage -40.5 V to -60 V
Power consumption max. 75 W
Parameter Value
Output from DC/DC
converters
+5 V and -5 V
Power LED Trigger
Level
Less than +4.9 V
More than -4.9 V
MA322 Rev. F1 59
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.5.7 Mechanical
Dimensions The dimensions of the Tellabs 6310 node is shown in the figure below.
Weight The weight is 4.7 kg
Air filter replacement To ensure optimum cooling under normal environmental conditions, it is rec-
ommended to replace the air filter every 12 months. In dusty conditions more
frequent replacement of filter might be necessary.
Transport The Tellabs 6310 node is not designed for transport installed in a rack, as this
may damage the mechanics. It is recommended to use the factory supplied
packaging.
Connectors The table specifies the connectors on the front and rear plate.
Function Equipment Connector Type Remarks
2 Mbit/s tributary (120 ) Shielded RJ-45 21, use shielded
cables
Synchronization (120 ) Shielded RJ-45 1, use shielded
cable
2 Mbit/s tributary (75 ) Coaxial 1.0/2.3 (IEC 169-29
and CECC 22 230) (female)
42
Synchronization (75 ) Coaxial 1.0/2.3 (IEC 169-29
and CECC 22 230) (female)
2
60 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
34 Mbit/s, 45 Mbit/s trib-
utary (75 )
Coaxial 1.0/2.3 (IEC 169-29
and CECC 22 230) (female)
6
10/100 Ethernet Shielded RJ-45 4 x 10/100 BaseT
Ethernet
Optical Ethernet tributary
input
LC, multi mode (single
mode for 1000BaseLX)
2 x 100 BaseFX
Ethernet or
2 x 1000 BaseSX/
LX Ethernet
Optical Ethernet tributary
output
Optical aggregate input LC, single mode 2 for ADM
1 for TM
Optical aggregate output
Management interface
(CT)
RJ-45 Craft terminal in-
terface. Use
shielded cable if
permanently
connected.
Management interface
(TRIB)
RJ-45 F-interface for
TRIB module.
Use shielded ca-
ble if permanent-
ly connected.
Management interface BNC 10 Base 2 Ether-
net
AUX (ALARM) 9 pole DIN 41652 (male) Use shielded ca-
ble
EOW 15 pole DIN 41652 (male) Use shielded ca-
ble
User Channels (UCH1/2) 15 pole DIN 41652 (male) Use shielded ca-
bles
-48 V DC 3 pole DIN 41652 (male)
Mains IEC 320 receptacle with
locking mechanism
Function Equipment Connector Type Remarks
MA322 Rev. F1 61
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Pin designations The figure shows the pin designations of the connectors.
62 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.5.8 Environmental
Climatic and mechanical
conditions
Classification according to ETSI ETS 300 019-1:
Storage:
ETS 300 019-1-1 class 1.2, not temperature controlled storage locations.
Transportation:
ETS 300 019-1-2 class 2.3, public transportation.
In use:
when AC powered:
ETS 300 019-1-3 class 3.2, stationary, weather protected, partly temper-
ature-controlled locations.
when DC powered:
ETS 300 019-1-3 class 3.3, stationary, weather protected, not tempera-
ture-controlled locations.
Climatic and mechanical
conditions
The table specifies climatic and mechanical conditions of the Tellabs 6310
node during storage, transport and operation.
Note: The temperature range is -5 C to +45 C for the ETEX8M, ETEX8S and
ETEX2S options.
Parameter Storage and Transportation In use
Temperature -40 C to +70 C when AC powered
-5 C to +45 C
when DC powered
-25 C to +55 C (see
note)
Humidity 10% to 100% RH, condens-
ing
5% to 100% RH, condens-
ing
Vibration Sinusoidal,
2 - 9 Hz, 3.5 mm
9 - 200 Hz, 10 m/s
2

200 - 500 Hz 15 m/s
2
Sinusoidal,
2 - 9 Hz 1.5 mm,
9 - 200 Hz 5 m/s
2
Shock Shock spectrum type I
11 ms 100 m/s
2
Shock spectrum type L
22 ms 40 m/s
2
Fall 1.2 m -
MA322 Rev. F1 63
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Climatic and mechanical
tests
Test severities according to EN 300 019-2:
Storage:
Test specification T 1.2
Transportation:
Test specification T 2.3
In use:
Test specification T 3.2 and T 3.3
Test sequence for
storage and
transportation
The table specifies the test sequence for storage and transportation.
Test sequence in use The table specifies the test sequence for in use.
Parameter Severity Reference
Temperature shocks -40/30 C, 1 C/min.,
t=3h, 5 cycles
IEC 60068-2-14 Nb
Mechanical shocks
400m/s
2
, 6ms, 6 x 500
shocks
IEC 60068-2-29 Eb
Humidity, condensa-
tion
25/40 C, 90-100% RH,
2 days
IEC 60068-2-30 Db 1
Low Temperature -40 C, 3 days IEC 60068-2-1 Ab
High Temperature 85 C, 3 days IEC 60068-2-2 Bb
Vibration, sinusoidal 5 - 9 - 200 - 500 Hz
3.5 mm - 10 - 15 m/s
2
1 octave/minute
3 x 5 sweep cycles
IEC 60068-2-6 Fc
High humidity 40 C, 93%RH, 4 days IEC 60068-2-56 Cb
Free Fall 1 m IEC 60068-2-32 Ed 1
Parameter Severity Reference
Low temperature when AC powered
-5 C, 16 h
when DC powered
-25 C, 16 h
IEC 60068-2-1 Ad
High temperature when AC powered
45 C, 16 h
when DC powered
55 C, 16 h
IEC 60068-2-2 Bd
Temperature change -5/45 C, 0.5 C/min
t1 = 3 h, 1 cycle
IEC 60068-2-14 Nb
Mechanical shocks
100 m/s
2
, 11 ms, 6 x 3
shocks
IEC 60068-2-27 Ea
64 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Functional tests are made during and at the end of each test to verify that per-
formance parameters are fulfilled.
3.5.9 EMC Conditions
Compliance The principal protection requirements of the EMC Directive 89/336/EEC are
satisfied.
Test specifications Verification of compliance with conditions is done by testing in accordance
with EN 300 386: Telecommunication Network Equipment, EMC require-
ments. Sub clause 7.2 Equipment operating in locations other than telecom-
munication centres.
EMC emission tests The table shows the EMC emission test specifications.
EMC immunity tests The immunity and resistibility performance criteria are according to EN 300
386 subclass 12.3.
Vibration,
sinusoidal
5 - 9 - 200 Hz,
1.5 mm - 5 m/s
2
3 x 5 sweep cycles
IEC 60068-2-6 Fc
Humidity,
condensation
25/40 C, 90-100%RH,
2 days
IEC 60068-2-30 Db 1
High humidity 40 C, 93%RH, 4 days IEC 60068-2-56 Cb
Parameter Severity Reference
Phenomenon Limits Reference
Enclosure Ports:
Electromagnetic Field
30-1000 MHz, 10m
30 - 230 - 1000 MHz
30 - 30/37 - 37 dBV/m
EN 55022
Class B
AC Power Supply Ports:
Conducted RF voltage
0.15 - 30 MHz
Quasi peak det.
Average det.
0.15 - 0.5 - 5.0 - 30 MHz
66 - 56 - 56/60 - 60 dBV
56 - 46 - 46/50 - 50 dBV
EN 55022
Class B
DC Power Supply Ports:
Conducted RF voltage
0.02 - 30 MHz
Quasi peak det.
Average det.
0.02 - 0.15 - 0.5 - 5.0 - 30 MHz
79 - 79/66 - 56 - 56/60 - 60 dBV
56 - 46 - 46/50 - 50 dBV
EN 55022
Class B and
EN 300 386
MA322 Rev. F1 65
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
EMC immunity tests for
enclosure ports
Specifications for enclosure ports.
EMC immunity tests for
AC power supply ports
Specifications for AC power supply ports.
EMC immunity tests for
DC power supply ports
Specifications for DC power supply ports.
Phenomenon Test Level Performance Reference
Electrostatic Discharge
contact/air exposure
6kV/0-8kV B EN 61000-4-2
8kV/0-15kV R
Electromagnetic Field
(26) 80 - 1000 MHz
80% AM, 1kHz
10 V/m A EN 61000-4-3
EN 300 386, sub
clause 12.2.2
Electromagnetic Field
GSM 900 MHz @ 200Hz
50% duty c.
10 V/m A ENV 50140
Phenomenon Test Level Performance Reference
Voltage Dips and
Short Interruptions
> 95 %, 10 ms B EN61000-4-11
30 %, 500 ms C
> 95 %, 5000 ms C
Radio Frequency
CM Voltage
0.15 80 MHz
80 % AM, 1 kHz
10 V A EN 61000-4-6
EN 300 386,
sub clause
12.2.2
Fast Transients
rise time 5ns
decay time 50ns
1 kV B EN 61000-4-4
2 kV C
Surge Transients
rise time 1.2s
decay time 50s
1 kV line to line
2 kV line to
ground
B EN 61000-4-5
2 kV line to line
4 kV line to
ground
R
Phenomenon Test Level Performance Reference
Voltage Variations
and Short Interrup-
tions
40.5 - 57.0 V
50.0 - 72.0 V 5V/
ms
A ETS 300 132-2
0 V in 4 ms A
0 V in 50 ms C
66 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
EMC immunity tests for
signal and control ports
Specifications for signal and control ports.
3.5.10 Safety
Compliance The principal protection requirements of the low voltage directive 73/23/EEC
are satisfied.
Safety requirements The requirements of EN 60950 Safety of information technology equipment
is fulfilled.
CAUTION: Double-pole / Neutral fusing.
The requirements of EN 60825-1: Equipment classification, requirements and
users guide, and EN 60825-2: Safety of optical fibre communication systems,
are fulfilled.
An automatic laser shutdown function is provided for the optical STM-1/
STM-4 interfaces. This function complies with ITU-T G.664: Optical safety
procedures and requirements for optical transport systems.
Radio Frequency
CM Voltage
0.15 80 MHz
80 % AM, 1 kHz
10 V A EN 61000-4-6
EN 300 386,
sub clause
12.2.2
Fast Transients
rise time 5ns
decay time 50ns
1 kV B EN 61000-4-4
2 kV C
Surge Transients
rise time 1.2s
decay time 50s
0.5 kV line to line
1 kV line to
ground
B EN 61000-4-5
1 kV line to line
2 kV line to
ground
C
0.5 kV C ITU-T K.41
Phenomenon Test Level Performance Reference
Phenomenon Test Level Performance Reference
Radio Frequency
CM Voltage
0.15 80 MHz
80% AM, 1kHz
10 V A EN 61000-4-6
EN 300 386,
sub clause 12.2.2
Fast Transients
rise time 5ns
decay time 50ns
0.5 kV B EN 61000-4-4
1 kV C
Surge Transients
rise time 1.2s
decay time 50s
0.5kV B EN 61000-4-5
0.5kV C ITU-T K.41
MA322 Rev. F1 67
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
3.5.11 R&TTE
Compliance The principal protection requirements of the Radio Equipment and Telecom-
munications Terminal Equipment Directive (R&TTE) 1999/5/EC are satis-
fied.
Requirements This is verified by performing the tests according to the EMC directive and the
LVD directive, i.e.:
EN 300 386: Telecommunication Network Equipment, EMC requirements.
Sub clause 7.2 Equipment operating in locations other than telecommuni-
cation centres, see part 5 of this document.
EN 60950: Safety of information technology equipment.
Connections It is only the optical interfaces of the Tellabs 6310 node, that are intended to be
connected to interfaces of public telecommunications networks.
The safety status of the electrical interfaces of the Tellabs 6310 node is SELV
circuit according to EN60950.
The electrical interfaces of the Tellabs 6310 node must only be connected to
other earthed equipment, and must not be connected directly to outdoor sig-
nal lines.
3.5.12 MTBF
Calculation method The FIT and MTBF values are calculated according to British Telecom Hand-
book of Reliability Data for components used in Telecommunication systems
[HRD5]/Telcordia SR-332. The used method is based on part count analysis
with parameters as described in the table below.
In the calculation of the FIT and MTBF values, the following parameters are
used for the electrical components, photo diodes and optical fibers. The con-
version from FIT to MTBF (years) is based on the following formula: MTBF =
1.14 x 10
5
/FIT
Reliability Calculation
parameters
The table lists the reliability calculation parameters.
Tempera-
ture
Environ-
ment
Connec-
tions
Quality level
Components Level
30 C Ground
Fix
Machine
soldered
or Press
Fit
Integrated Circuits and
Transistors
HRM2
Discrete Semiconduc-
tors
PLS2
Active Components HRM2
Passive Components LEV2
Miscellaneous Parts LEV2
68 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
FIT and MTBF for
Tellabs 6310 node
without main and trib
modules
The table below specifies the FIT and MTBF values for the Tellabs 6310 node
without the main and trib modules.
FIT and MTBF for main
modules
The table below specifies the FIT and MTBF values for main modules in the
Tellabs 6310 node.
FIT and MTBF for trib
modules
The table below specifies the FIT and MTBF values for trib modules in the Tel-
labs 6310 node.
To calculate the MTBF
for the Tellabs 6310
node
Use the procedure below to calculate the MTBF for a specific configuration of
the Tellabs 6310 node.
Item Description FIT MTBF
CU3690-xxxx Unit without main and trib modules,
AC/DC
2816 40.5
CU3691-xxxx Unit without main and trib modules,
DC
2360 48.3
Item Description FIT MTBF
TM1 Terminal Multiplexer, STM-1 6785 16.8
ADM1 Add/drop multiplexer, STM-1 7862 14.5
ADM4 Add/drop multiplexer, STM-4 7862 14.5
Item Description FIT MTBF
TEX31 1 x 34 Mbit/s 1789 63.7
TEX33 3 x 34 Mbit/s 2151 53.0
TEXDS31 1 x 45 Mbit/s 1789 63.7
TEXDS33 3 x 45 Mbit/s 2151 53.0
ETEX4 4 x 10/100 Mbit/s Ethernet (electri-
cal)
2901 39.3
ETEX8M/S 4 x 10/100 Mbit/s Ethernet (electri-
cal) and 2 x 100 Mbit/s Ethernet (op-
tical)
6495 17.6
ETEX2S 2 x 1 Gbit/s Ethernet (optical) 6147 18.6
Step Action
1 Find the separate FIT values for the unit without main and trib mod-
ules, the main module and the trib module for a specific unit.
Find the values in FIT and MTBF for Tellabs 6310 node without
main and trib modules on page 68, FIT and MTBF for main mod-
ules on page 68 and FIT and MTBF for trib modules on page 68.
2 Calculate the total FIT value for the unit by adding the separate FIT
values.
MA322 Rev. F1 69
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
Operational lifetime The Tellabs 6310 node unit is designed for a 15 year lifetime.
3 Calculate the MTBF (years) using the formula: MTBF=114000/FIT
Step Action
70 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
3 Reference Information
MA322 Rev. F1 71
Tellabs

6310 Edge Node


Flexible Version, 2U High
A Packing Instructions
A Packing Instructions
Overview This appendix describes the recommended procedures to follow when pack-
ing modules for shipment.
Use original packing
material
It is recommended to use the original packing material from the factory. But
if the material is not available then follow the instructions here when packing
modules for shipment.
Required materials If you do not have the original packing material, then the following materials
are required for packing the module.
Antistatic bag (antistatic inner layer and metal coated outer layer) with a
suitable size
Carton-box with a suitable size
Foam supporting pad with dimensions that fit the box.
To pack the module Follow the instructions below when you are packing the module before ship-
ment.
Step Action
1 Put an antistatic bracelet on your wrist, and connect the bracelet to
ESD ground on the workplace.
Note: Make sure that the workplace, on which you are connecting the
bracelet, is correctly ESD grounded.
72 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
A Packing Instructions
2 Place the module in the antistatic bag.
Note: Only one module per bag
3 Unfold/assemble the carton-box
4 Place the lower part of the foam supporting pad in the bottom of the
box.
Step Action
MA322 Rev. F1 73
Tellabs

6310 Edge Node


Flexible Version, 2U High
A Packing Instructions
5 Place the module with the top side up into the box, carefully wrap-
ping the antistatic bag around the module.
Note: Only one module per box
6 Place the upper part of the foam supporting pad in the box.
Step Action
74 MA322 Rev. F1
Tellabs

6310 Edge Node


Flexible Version, 2U High
A Packing Instructions
7 Close the box
Use tape if necessary to ensure that the box stays closed during trans-
portation.
Step Action
Tellabs

6310 Edge Node


Flexible Version, 2U High
Index
MA322 Rev. F1 75
Index
A
Abbreviations 11
AC input 42, 58
Air filter 30
B
Block diagram
Power system 42
Unit 40
C
Cable types 23
Cabling 23, 27
Cautions 7
Connecting cables 23
Connectors 38
Considerations 17
D
DC input 42, 58
Definition of Terms 12
Description 40
Dimensions 59
E
EMC 64
Environmental 62
Equipment labels 18
F
Filter 30
Front Layout 35
Functional description 40
I
Identification
Labels 18
Settings 29
IDs 29
Installation
Connecting cables 23
In rack 20
Installing cables 23
Item numbers 36
L
Labels 18
Layout 16, 35
LEDs 38
Location 18
Logistics 36
M
Management 15
Management interface 55
Manual
Purpose 11
Structure 11
Mechanical 59
MTBF 67
N
Numbers 36
O
Optical Safety 17
Ordering numbers 36
P
PDH interface 45
Physical placement 18
Pin designations 61
Power 58
Protection 15, 41
Purpose of manual 11
R
R&TTE 67
Rack ID 29
References 13
Replacing
Filter 30
Tributary Module 31
S
Safety 17, 66
Slot ID 29
Specification
EMC 64
Environmental 62
Ethernet interface 49
Management interface 55
Tellabs

6310 Edge Node


Flexible Version, 2U High
Index
76 MA322 Rev. F1
Mechanical 59
MTBF 67
PDH electrical interface 45
Power 58
R&TTE 67
Safety 66
STM-1/4 optical interface 43
Synchronization interface 52
STM-1 interface 43
STM-4 interface 43
Structure of manual 11
Subrack ID 29
Synchronization interface 52
T
Terms 12
W
Warnings 7
Weight 59