Typical Applications: Radio base stations Smaller telecom exchanges Private branch exchanges Nominal system voltage +24V EMC EN 300 386 System characteristics: Adjustable output voltage range 23V ... 28.5V Marking CE Electrical safety EN 60950 ACTURA Optima 24350 Maximum normal load current 200A +24V DC, 1.6 ... 9.6kW ACTURA General The ACTURA Optima 24350 is a flexible power system suitable for communication networks and IT applications requiring small to medium range power. This system is designed to reliably and cost effectively provide uninterrupted power to various types of communication and IT equipment. The 24350 is a positive 24V system that is suitable for supplying loads of up to 8kW with N+1 rectifier module redundancy. The system is supplied in a cabinet which includes provision for distribution and battery circuit breakers. The picture shown is a system equipped with an ACTURA DC to DC sub rack and modules. The compact size of the ACTURA Optima 24350 power system allows available space to be used effectively for revenue generating equipment. Comprehensive supervision and remote access facilities are also provided which facilitate complete management of your energy infrastructure. Two ACTURA Optima systems may be paralleled for higher power requirements. Of utmost importance to Emerson Energy Systems, is a high standard of quality. Our ISO9001 certification is an indication of our commitment to continual quality improvement. Both the system and modules carry the CE mark of approval. Data centres Other data or communication equipment requiring +24V power supply Rated output power 9.6kW Rated rectifier output current 360A Maximum priority load current 200A Features Fully pre-wired, including all battery wiring, which allows low installation costs Comprehensive supervision including self diagnostic features Remote alarm extension Alarm log for statistical system data Repairs possible on live system Two stage low voltage disconnect - Priority load & normal load Full battery management maximizes system integrity System prepared for battery block voltage equalisers Automatic battery discharge testing Individual block monitoring for up-to 8 strings Temperature compensated float voltage SMS alarm feature Included in standard system : AC Distribution Rectifier circuit breakers 6 x 15A Mains low voltage detector 185 ... 190V AC per phase to neutral Rectifier capacity Up to 6 SM2415-1 rectifier modules Two level disconnect Priority and normal loads Normal load circuit breakers 3 x 100A + 2 x 10A Maximum number of load circuit breakers 15 x single pole Battery backup Capacity Up to 4 x 200Ah Battery circuit breakers 4 x 125A Battery compartment cover plates 4 Control / supervision module 1 Included in standard system: Mechanical data of the system: Dimensions 1860mm (H) x 600mm (W) x 600mm (D) Net weight (Approximately) 90kg (excluding modules & batteries) Packed weight (Approximately) 120kg (excluding modules & batteries) Emerson Energy Systems (Pty) Ltd 2 Kikuyu Rd. Sunninghill Ext. 96 Republic of South Africa Phone: +27 11 257 8500 Fax: +27 11 807 8103 www.emersonenergy.co.za www.emersonenergy.com Dimensions 96mm (H) x 135mm (W) x 360mm (L) Safety EN 60 950 EMC, including surge immunity EN 300 386 Weight 3.6kg Enclosure IP20 Reliability, MTBF (Module) >50 years Input characteristics: Input voltage range for start-up 170 ... 275Vac Non-destructive input voltage range 0 ... 320Vac Maximum input current, incl. inrush current <12A AC ac Line frequency 45 ... 65Hz Output characteristics: Ouput voltage 27Vdc Line regulation <0.1% Load regulation <0.5%% Psophometric weighted noise <1mV at +27V Rated output current 60A Current sharing Within 5% of rated output current Efficiency at 230V AC 50 ... 100% load >90% Protection characteristics: Output short circuit protection Over and under voltage protection Overheat protection Environmental conditions: Operational temperature range -5 ... 65C Storage temperature range -25 ... 65C Cooling Forced convection non-condensing with built in low noise speed control fan The ACTURA Optima24350 is also available in different configurations. The ACTURA Optima DC to DC sub rack & modules compliment this system. Preliminary Data Sheet E. & O.E. {Actura24350a7.cdr} DC Distribution Priority load circuit breakers 1x 100A + 5 x 10A Packed dimensions (Approximately) 2040mm (H) x 820mm (W) x 750mm (D) General: Technical Specifications rectifier module (SM2415-1) Active load sharing Yes Input voltage range (after start-up) 80 ... 275Vac Input voltage range 175 ... 275Vac for maximum power (1600W) Power factor, 50 ... 100% load >0.995 Maximum input current THD, 50 ... 100% load 5% Quality system ISO9001 Operational temperature range -5 ... + 65 C Normal operation temperature range (up to 9.6kW) 0 ... + 45 C Nominal input voltage range, 1 (1+N+E) 220 ... 240V AC Nominal input voltage range, 3 (3+N+E) 380 ... 415V AC Maximum input current 72A 1 , or 3 x 24A 3 Nominal input frequency range 50 ... 60Hz
System characteristics (contd):
Adjustable output voltage range 23 ... 28.8Vdc Rated output power 1600W (De-rate below 175Vac)