542876 CODE: {Last 6 digits of your student number.} X=8 ex. Stud. No. 2010542876 Y=7 Z=6 A. TYPE OF OCCUPANCY: Z 0 to 3: School Building 4 to 6: Commercial Building 7 to 9: Residential Building B. TYPE OF TRUSS: Y even Pratt Truss odd Howe Truss Howe Truss Pratt Truss Note: Number of web members may vary depending on maximum slenderness ratio C. PROJECT LOCATION: X 0 to 3: Zone 3 4 to 6: Zone 1 7 to 9: Zone 2 D. SPAN OF TRUSS, ST = [8+Y/4+X/4] meters E. HEIGHT OF TRUSS (RISE), H = Maximum of 2 meters F. BAY DISTANCE, L = [6+Z/4] meters B-1 B-1 B-1 B-1 ST/2 check if this column is necessary ST/2 B-1 B-1 B-1 B-1 L L L L 2ND FLOOR FRAMING PLAN Specify Concrete Slab Thickness: {100-150mm} Beams and Columns are made of Wide-Flange Sections Wide Flange Columns {orientations of column may not be correct} B - 2
B - 2
B - 2
B - 2
B - 2
B - 2
B - 2
B-3 B-3 B-3 B-3 B - 2
B - 2
B - 2
ST/2 ST/2 ROOF FRAMING PLAN C (Channel) Purlins with Sagrods & Tierods {specify your own spacing between purlins and verify} Roofing: Corrugated Galvanized Iron (G.I.) {specify your own gage #} or you can specify your own chosen roofing specs G. HEIGHT OF COLUMN, H H1=H2 = [3+X/5] meters roof apex top of beam H2 2nd floor line H1 natural grade line LEFT SIDE ELEVATION T - 1
T - 1
T - 1
T - 1
T - 1
B-4 B-4 B-4 B-4 B-4 B-4 B-4 B-4 B-5 B-5 B-5 B-5 REQUIREMENTS: 1. Plans and Drawings a. Perspective b. Ground Floor Plan / Second Floor Framing Plan/ Roof Framing Plan c. Elevations (Front Elev. /Rear Elev. /Right Side Elev. /Left Side Elev.) d. Structural Details and Specifications 2. Structural Analysis and Design a. Basis of Design b. Loading Computations c. Design of Purlins, Sagrods and Tierods d. Loadings and Analysis of Truss e. Design of Top Chord f. Design of Bottom Chord g. Design of Web Members h. Design of Beams and Girders i. Design of Column j. Design of Base Plate k. Design of Connection (Bolted, Riveted or Welded) l. Appendices m. Acknowledgment Guidelines: 1. All structural steel must comply with ASTM A36 steel specifications. (Except for purlins, use only light gage lip C purlins with Fy=170MPa and 2. Deadloads, Liveloads, and Windloads shall be considered. Equake Load (optional) 3. Analyze the structure based on the most critical loading combination. 4. Analyze the TRUSS structure using STAAD Program or any Design Freeware. 5. Analyze the structure (frames, beams and columns) using 2-D/3-D Frame Analysis applying any classical method. However, STAAD may also be used for frame analysis provided that short but precise manual calculations be done to verify software's output. 6. Progress Reports shall be hand written in A4 sized bond papers in customized templates and must be submitted/uploaded thru our Canvas account. 7. Final Project Report must be compiled and be submitted during the scheduled day of oral defense (usually 1 week before the scheduled final exam). tierod & sagrod with grade40 yield strength) Roofing: Corrugated Galvanized Iron (G.I.) {specify your own gage #} or you can specify