You are on page 1of 39

GD Midea Commercial Air-conditioning Equipment Co., Ltd.

Add: Midea Industrial City, Shunde, Foshan, Guangdong, 528311, P.R.China


Tel: +86-757-26339642

Fax: +86-757-26339337

E-mail: mcac@midea.com.cn
Http: //www.midea.com.cn
Http: //www.mdvchina.com (customer service)

2007

Midea Air Conditioners


Commercial Aircon System 50HZ

Midea Is Your Idea

Midea Creates A Better Life

Midea produced its first Air


Conditioner in 1984. Currently
we are the industry leader for Air
conditioner manufacturing and
export. Midea has been

We provide Global technical

exporting Air Conditioners for the


last 16 years, and during this

110 countries and regions


receive top quality service at
all times.

training and a comprehensive


online customer service. All
of our customers from over

time has cultivated strong


partnerships with hundreds of
overseas companies.

The year of 1999 has witnessed

Nowadays, Midea can offer the


fullest range of commercial air
conditioner in China. It consists

Midea's entry into the field of

of Multi Digital Variable System:

commercial air conditioner. The

Digital scroll A/C system, Inverter

leading-edged technology, state-of-

commercial A/C system; Light

art assembly lines, and years' of

Chiller System: Mini air-cooled


chiller system, Modular air-cooled

experience in air conditioner field have


Our vertically integrated supply
chain allows us to achieve
maximum efficiency in production
and product development.

chiller system, Water-cooled

made Midea as the leader in the field

Packaged unit, Heating water

of commercial air conditioner in China.

system; Commercial Chiller


System: Screw chiller system,
Centrifugal chiller system.

TUV Rheiniand

MI TY C ERT

RAM

IZAT
RG
N ST
A N D AR D S O

NFOR

ROG

AN

B IA

CO

NP

ON

AL

AT

IO

ATI

A RA

L I
S T E D

INTE RN

068

ISO 14001: 1996


Certificate No.:CC1417

SA U D I

068

ISO 9001 : 2000


Certificate No.: CC 454

ION

CERTIFIED
COMPANY

CERTIFIED
COMPANY

geprufte
sicherheit

NRTL/C

IFIC

..
geprufte
Sicherheit

E U R OV E N T

CERTIFIED PERFORMANCE

TUV Rheiniand
Group

Production inspected

N433

Full Range of R410A


Digital Scroll A/C System

Intelligent Built-in Manager System


Intelligent Manager is an integrated building management system(BMS) that uses our independent, high-speed

Feature of R410A system

R410A

Friendly Refrigerant, save energy and protect environment


Good performance of cooling & heating.

The component of the R410A is close to azeotropy, with little change of the component
structure, the capability will not decrease during the recharge period.
Do not contain the element Chlorine, protect the ozonosphere

R410A

multi-transmission method. It has a centralized controller function that can perform high-speed centralized control
of our commercial A/C for buildings.

MDV system has various control solutions:


Individual control, Group control, Network control, etc.
1 computer can monitor max 16 central controllers.
1 central centroller can monitor max 64 indoor units.
1 computer can monitor max 1024 indoor units.

BMS

*Elevator
*Pump
*Lighting
...etc.

Basic modules
5 basic modules: 8HP, 10HP, 12HP, 14HP, 16HP

Fire alarm

Security

Power supply facility

2HP increments of capacity


R

LON bus
over ethernet

Basic modules

Free combination, wide range


5 basic modules, which can be freely assembled.

Max=32

2HP increments of capacity range, which meets customers' needs accurately;


Maximum capacity is 64HP.

Lonwork

Max=64

50-64HP
34-48HP
Max=16

18-32HP

Max=64
Built-in manager
system

8-16HP
Touch controller

Central controller

Remote controller

Intelligent Built-in Manager System


Independent Calculating System
POWER

Model selection software


Windows version

POWER

POWER

Operate directly on Windows interface; friendlier


interface makes its applicable range much wider.
Main functions includes load calculation, multi-

CCM

split and chilled water system selection, explicit


Max=64

quotation table output, hydraulic calculation,


capacity inquire with changeable outdoor
environment (for multi-split) or nonstandard

CCM

working criteria (for chiller), etc.


Coverter

Update with product change.

POWER
Built-in manager
system

Digital Ammeter

Independent calculation Report


Independent calculation and output with report, easy to know the charge of the A/C.

Group setting, simple and efficient.

Schedule setting, no need to worry


during the operation of A/C

CAD version
Professional software that helps engineers design project easily, quickly and conveniently. Main

a huge A/C system. The

With the advanced Schedule setting mode, the


PC can easily manage the daily work of A/C. The
system can set the weekly plan of A/C and operate

group setting can control

automatically in cycle.

One group consists of on-line A/Cs in different


Central controllers, maximum 1024 units.
One system can be set by 16 groups to manage

each on-line unit, unionize


them to be On / Off or

Two versions each compatible with AutoCAD 2000/2002 and AutoCAD 2004/2005

functions include load calculation, equipment selection, pipeline setting, system figure configuration,
quotation table automatic output, refrigerant volume calculation, wiring and installation diagram
output, etc.
Update with product change

change the parameters. It's


so convenient and easy.

2007 Midea Commercial A/C Model Line Up


9'000

DC I nverter
F our-way
Cas s ette

12'000

18'000

24'000

30'000

36'000

48'000

60'000

72'000

R410A

13

R410A
DC I nverter
F our-Way
Cas s ette( Compact)

DC I nverter
Ceiling & F loor
type

14

R410A

15
R410A

DC I nverter
Duct type

16
R410A

F our-way
Cas s ette

R407C

17

R22
R410A

F our-way
R407C
Cas s ette( compact)

18

R22

R410A

One-way
Cas s ette

R407C

19

R22
R410A

Ceiling & F loor


type

20

R407C
R22
R410A

Duct type

21

R407C
R22
R410A

H igh S tatlc
P res s ure Duct

R407C

22

R22
R410A

H igh S tatlc
P res s ure Duct

R407C

23

R22
R410A

Duct( s lim) Type

R407C

24

R22
R410A

F loor-s tanding

R407C

25

R22
R410A

Univers al
Outdoor Unit

R407C

26

R22

2007 Midea Commercial A/C Model Line Up


R22

R410A

[ H ] Multi System
29-43

R407C

R410A

R410A

R410A

R410A

R407C

R22

53-62

R410A

[ D ] Digital Scroll A/C System

R410A

Split Wall-Mounted
AC Inverter Multi Eco

DC(AC) Inverter Multi

10kW

14kW

28-84kW

25.2-180kW
R410A
R410A

Four-way cassette

One-way cassette
(compact)

Low static
pressure duct

Duct

High static
pressure duct

Ceiling & Floor

Floor standing

R407C

R407C

Four-Way Cassette
R22

Wall-mounted

Multi Star

Multi Series

R410A

R22

R407C

[ R ] Heating Water System

R22

63-67

44-49

[ V ] Inverter A/C System (DC/AC)

Duct

8kW

Four-way cassette

12-14kW

One-way cassette
(compact)

Low static
pressure duct

25.2-180kW

16-18kW

Duct

High static
pressure duct

Ceiling & Floor

Floor standing

Wall-mounted

7kW

R407C

17.5kW

35kW

R22

50-52

[ M ] Multi Variable A/C System

9kW

Accessories
68-76

Four-cassette type(12.5kW)

Four-cassette type(6kW)

High static pressure


Duct type(13kW)

12kW
Duct type(slim)(6kW)

Heat Recovery Ventilator

26kW

Auxiliary Electric Heater

Auxiliary Electric Heater

Duct type(13kW)

10

DC Inverter

[ U ] Series

Unitary System

Single ON/OFF

Universal Out Unit

DC Inverter

DC Inverter

Four-way Cassette

Four-way Cassette(compact)

220-240V~,380V~,50Hz

R410A

R410A

Fresh air makes life more healthy and comfortable


Fresh air
intake

Panel

The Sketch Map of Installation

650mm

580mm

Fresh air

580mm

650mm

Four-way Airflow

3-Dimentional Screw Fan

254mm

Specification:

Specification:
Capacity

Performance
Electrical Data

Model

Cooling Heating
Btu/h

MCA-24CRDN1

24000

MCA-24HRDN1

24000

MCA-30CRDN1

30000

MCA-30HRDN1

30000

MCA-36CRDN1

36000

MCA-36HRDN1

36000

MCA-48CRDN1

48000

MCA-48HRDN1

48000

Btu/h

Voltage, Hz, Phase

m3/h

dB(A)

220-240,50,1(380,50,3)

1050

40

Net Dimension

Packing Dimension

Net Weight

Body

Panel

Body

Gross Weight Oty'Per 20'/40'/40'HQ

mm

mm

kg

kg

kg

27

34

1600

40

Packing Dimension

Net Weight

Air Flow
Volume

Noise
Level

Body

Panel

Body

Panel

Body Panel Body Panel

Voltage, Hz, Phase

m3/h

dB(A)

mm

mm

mm

mm

220-240,50,1

780

36

220-240,50,1

860

40

Capacity

Performance
Electrical Data

Body

Panel

mm

mm

840x240x840

950x40x950

955x260x955 1030x145x1030

Panel Body Panel

Indoor

Set

kg

Pieces

Pieces

11

72/150/168

32/66/76

27300
220-240,50,1(380,50,3)

13

Air Flow Noise


Volume Level

840x310x840

950x40x950

955x325x955 1030x145x1030

33

40

11

48/102/122

25/55/62

32000
220-240,50,1(380,50,3)

1600

44

840x310x840

950x40x950

955x325x955 1030x145x1030

33

40

11

48/102/122

25/55/62

380,50,3

1750

44

840x310x840

950x40x950

955x325x955 1030x145x1030

33

40

11

48/102/122

24/50/55

Model

Cooling Heating
Btu/h

MCA-12CRDN1

12000

MCA-12HRDN1

12000

MCA-18CRDN1

18000

MCA-18HRDN1

18000

Btu/h

Net Dimension

Gross Weight

Oty'Per 20'/40'/40'HQ
Indoor

Set

kg

kg

kg

kg

Pieces

Pieces

580x254x580 650x30x650 750x340x750 715x115x715

21

28

119/249/252

56/123/140

580x254x580 650x30x650 750x340x750 715x115x715

21

28

119/249/252

56/123/140

13000

20500

38000

52000

14

DC Inverter

DC Inverter

Ceiling & Floor type

220-240V~,380V~,50Hz

Duct type

220-240V~,380V~,50Hz

R410A

R410A

Auto Swing & Wide-angle Airflow

750mm

Special Up-drainage water pump(optional)

The sketch map of installation

298mm

Air intake from below

Water proof by utilizing the absorbing


plastic film on water collector.

Air intake from back

Optional

Front clapboard

(18000-60000Btu/h)

Panel

Canvas air passage

Filter

Specification:
Capacity

Performance
Electrical Data

Model

Cooling
Btu/h

Weight

Dimension

Oty'Per 20'/40'/40'HQ

Heating

Air Flow
Volume

Noise
Level

Body

Package

Net

Gross

Indoor

Set

Btu/h

dB(A)

mm

mm

kg

kg

Pieces

Pieces

Voltage, Hz, Phase

m /h

Specification:
Capacity

Performance
Electrical Data

MUB-12CRDN1

Model

12000
220-240,50,1

MUB-12HRDN1

12000

MUB-18CRDN1

18000

MUB-18HRDN1

18000

MUB-24CRDN1

24000
24000

MUB-30CRDN1

30000

MUB-30HRDN1

30000

MUB-36CRDN1

36000

MUB-36HRDN1

36000

MUB-48CRDN1

48000

MUB-48HRDN1

48000

MUB-60CRDN1

60000

MUB-60HRDN1

60000

995x660x198

1080x740x290

29

34

128/264/295

800

38

995x660x198

1080x740x290

29

34

128/264/295

40

995x660x198

1080x740x290

29

34

128/264/295

1200

41

1285x660x198

1365x740x290

35

41

97/202/226

1400

41

1285x660x198

1365x740x290

35

41

97/202/226

1800

42

1670x680x240

1760x760x330

50

60

67/137/165

380,50,3

2000

42

1670x680x240

1760x760x330

50

60

67/137/165

Package

Net

Gross

Indoor

Set

Btu/h

Voltage, Hz, Phase

m3/h

dB(A)

Pa

mm

mm

kg

kg

Pieces

Pieces

MTA3-18HRDN1

18000

220-240,50,1

1160

38

40

1000x298x800

1205x370x940

33

44

60/126/156

34/76/94

MTA3-24CRDN1

24000

MTA3-24HRDN1

24000

220-240,50,1(380,50,3)

1460

42

40

1000x298x800

1205x370x940

33

44

60/126/156

30/70/76

MTA3-30CRDN1

30000

MTA3-30HRDN1

30000

220-240,50,1(380,50,3)

2070

44

70

1350x298x800

1555x370x940

48

57

48/100/112

24/52/62

MTA3-36CRDN1

36000

MTA3-36HRDN1

36000

220-240,50,1(380,50,3)

2070

44

70

1350x298x800

1555x370x940

48

57

48/100/112

24/52/62

MTA3-48CRDN1

48000

MTA3-48HRDN1

48000

380,50,3

2400

44

70

1350x298x800

1555x370x940

48

57

48/100/112

24/52/62

MTA-60CRDN1

60000

MTA-60HRDN1

60000

380,50,3

2800

46

100

1350x320x800

1555x440x940

70

80

36/84/98

21/44/50

20500

27300

32000

38000

25/50/54

52000

68000

Body

27/55/62

38000
380,50,3

External Static
Pressure

27/55/62

32000
220-240,50,1(380,50,3)

Noise
Level

44/94/101

27300
220-240,50,1(380,50,3)

18000

Oty'Per 20'/40'/40'HQ

Air Flow
Volume

49/104/126

20500
1000

MTA3-18CRDN1

Weight

Dimension

Heating

63/138/155
Btu/h

220-240,50,1(380,50,3)

15

36

13000
220-240,50,1

MUB-24HRDN1

600

Cooling

52000

25/50/54
68000

16

Four-way Cassette

Four-way Cassette(compact)

220-240V~,380V~,50Hz

R410A

R410A

R407C

R407C

R22

R22

Fresh air makes life more healthy and comfortable


Fresh air
intake

Panel

The Sketch Map of Installation

650mm

580mm

Fresh air

580mm

Four-way Airflow

3-Dimentional Screw Fan

650mm

254mm

Specification:
Performance

Capacity
Electrical Data
Model

Cooling Heating
Btu/h

Btu/h

Voltage, Hz, Phase

Air Flow Noise


Volume Level
m3/h

dB(A)

Net Dimension

Packing Dimension

Net Weight

Body

Panel

Body

Panel

Body

mm

mm

mm

mm

kg

Gross Weight Oty'Per 20'/40'/40'HQ

Panel Body
kg

kg

Panel

Indoor

Set

kg

Pieces

Pieces

Specification:
Packing Dimension

Net Weight

Air Flow
Volume

Noise
Level

Body

Panel

Body

Panel

Body

Voltage, Hz, Phase

m3/h

dB(A)

mm

mm

mm

mm

kg

kg

220-240,50,1

780

36

580x254x580

650x30x650

750x340x750 715x115x715

21

220-240,50,1

860

40

580x254x580

650x30x650

750x340x750 715x115x715

21

Capacity

Performance
Electrical Data

MCA-24CR(N1)(N2) 24000
MCA-24HR(N1)(N2) 24000
MCA-30CRN1

30000

MCA-30HRN1

30000

MCA-30CRN2

30000

MCA-30HRN2

30000

MCA-30CRN2

30000

MCA-30HRN2

30000

220-240,50,1(380,50,3)

1050

40

840x240x840 950x40x950

955x260x955 1030x145x1030

27

34

11

72/150/168 32/66/76

Model

27300

Cooling Heating
Btu/h

220-240,50,1(380,50,3)

1600

40

840x310x840 950x40x950

955x325x955 1030x145x1030

33

40

11

48/102/122 25/55/62

32000
220-240,50,1

1600

40

840x310x840 950x40x950

955x325x955 1030x145x1030

33

40

11

48/102/122 25/55/62

32000

MCA-12CRN1(N2)

12000

MCA-12HRN1(N2)

12000

1050

40

840x240x840 950x40x950

955x260x955 1030x145x1030

27

34

11

72/150/168 32/66/76

220-240,50,1(380,50,3)

1600

44

840x310x840 950x40x950

955x325x955 1030x145x1030

33

40

11

48/102/122 25/55/62

380,50,3

1750

44

840x310x840 950x40x950

955x325x955 1030x145x1030

33

40

11

48/102/122 24/50/55

Gross Weight

Panel Body

Oty'Per 20'/40'/40'HQ

Panel

Indoor

Set

kg

kg

Pieces

Pieces

28

119/249/252 56/123/140

28

119/249/252 56/123/140

15000

MCA-18CR(N1)(N2) 18000
MCA-18HR(N1)(N2) 18000

380,50,3

Btu/h

Net Dimension

20500

32000

MCA-36CR(N1)(N2) 36000
MCA-36HR(N1)(N2) 36000

38000

MCA-48CR(N1)(N2) 48000
MCA-48HR(N1)(N2) 48000

17

52000

18

One-way Cassette

220-240V~,50Hz

Ceiling & Floor type

220-240V~,380V~,50Hz

R410A

R410A

R407C

R407C

R22

R22

Auto Swing & Wide-angle Airflow

Ultra Thin, Space Saving

235mm

Water proof by utilizing the absorbing


plastic film on water collector.

Ultra Thin

Drain pump can lift


Drain water up to 750mm upmost.

Suitable to be set at corners

Specification:

750mm upmost

Single direction airflow, flexibly


installed in various corners

Capacity

Cooling
Heating

Specification:
Capacity

Performance
Electrical Data

Model

MCB-09CR(N1)(N2)

9000

MCB-09HR(N1)(N2)

9000

MCB-12CR(N1)(N2)

12000

MCB-12HR(N1)(N2)

12000

Btu/h

Net Weight

Gross Weight

Air Flow
Volume

Noise
Level

Body

Panel

Body

Panel

m3/h

dB(A)

mm

mm

mm

mm

kg

kg

kg

kg

220-240,50,1

470

35

1080x310x460

1120x172x540

23

27

850x235x400 1050x18x470

Body Panel Body Panel

13000

500

35

850x235x400 1050x18x470

1080x310x460

1120x172x540

23

27

Cooling

Heating

Btu/h

Btu/h

MUB-12CR(N1)(N2)

12000

MUB-12HR(N1)(N2)

12000

MUB-18CR(N1)(N2)

18000

MUB-18HR(N1)(N2)

18000

MUB-24CR(N1)(N2)

24000

MUB-24HR(N1)(N2)

24000

MUB-30CRN1

30000

MUB-30HRN1

30000

MUB-30CRN2

30000

MUB-30HRN2

30000

MUB-30CRN2

30000

Oty'Per 20'/40'/40'HQ

MUB-30HRN2

30000

Indoor

Set

MUB-36CR(N1)(N2)

36000

Pieces

Pieces

MUB-36HR(N1)(N2)

36000

MUB-48CR(N1)(N2)

48000

MUB-48HR(N1)(N2)

48000

MUB-60CR(N1)(N2)

60000

MUB-60HR(N1)(N2)

60000

115/238/268 72/152/160

10000
220-240,50,1

19

Packing Dimension

Voltage, Hz, Phase

Cooling Heating
Btu/h

Net Dimension

Performance
Electrical Data

Model

115/238/268 60/132/148

Dimension

Weight

Oty'Per 20'/40'/40'HQ

Air Flow
Volume

Noise
Level

Body

Package

Net

Gross

Indoor

Set

Voltage, Hz, Phase

m3/h

dB(A)

mm

mm

kg

kg

Pieces

Pieces

220-240,50,1

600

36

995x660x198

1080x740x290

29

34

128/264/295

63/138/155

220-240,50,1

800

38

995x660x198

1080x740x290

29

34

128/264/295

49/104/126

220-240,50,1(380,50,3)

1000

40

995x660x198

1080x740x290

29

34

128/264/295

44/94/101

220-240,50,1(380,50,3)

1200

41

1285x660x198

1365x760x278

35

41

97/202/226

27/55/62

220-240,50,1

1200

41

1285x660x198

1365x760x278

35

41

97/202/226

27/55/62

380,50,3

1000

40

995x660x198

1080x740x290

29

34

128/264/295

44/94/101

220-240,50,1(380,50,3)

1400

41

1285x660x198

1365x740x290

35

41

97/202/226

27/55/62

380,50,3

2000

42

1670x680x240

1760x760x330

50

60

67/137/165

25/50/54

380,50,3

2000

42

1670x680x240

1760x760x330

50

60

67/137/165

25/50/54

13000

20500

27300

32000

32000

32000

38000

52000

65000

20

Duct type

220-240V~,380V~,50Hz

High Statlc Pressure Duct

220-240V~,380V~,50Hz

R410A

R410A

R407C

R22

R407C
R22

750mm

Special Up-drainage water pump(optional)

The sketch map of installation

298mm
298mm

Air intake from below

Air intake from back

Optional

(18000-60000Btu/h)

The longest distance of


air supply is 14m

Front clapboard

Panel

Canvas air passage

Induct Some Fresh Air

Filter

INDOOR UNIT
Outtake

Specification:
Capacity

Performance
Electrical Data

Model

Cooling

Heating

Btu/h

Btu/h

MTA3-12CRN1

12000

MTA3-12HRN1

12000

MTA3-18CR(N1)(N2)

18000

MTA3-18HR(N1)(N2)

18000

MTA3-24CR(N1)(N2)

24000

MTA3-24HR(N1)(N2)

24000

MTA3-30CRN1

30000

MTA3-30HRN1

30000

MTA3-30CRN2

30000

MTA3-30HRN2

30000

MTA3-30CRN2

30000

MTA3-30HRN2

30000

MTA3-36CR(N1)(N2)

36000

MTA3-36HR(N1)(N2)

36000

MTA3-48CR(N1)(N2)

48000

MTA3-48HR(N1)(N2)

48000

MTA-60CR(N1)(N2)

60000

MTA-60HR(N1)(N2)

60000

MTA-72CR(N1)(N2)

72000

MTA-72HR(N1)(N2)

72000

MTA-96CR(N1)(N2)

96000

MTA-96HR(N1)(N2)

96000

Weight

Oty'Per 20'/40'/40'HQ

Noise
Level

External Static
Pressure

Body

Package

Net

Gross

Indoor

Set

Voltage, Hz, Phase

m3/h

dB(A)

Pa

mm

mm

kg

kg

Pieces

Pieces

220-240,50,1

580

35

10

955x210x385

1044x277x439

15

19

210/510/572

95/202/210

220-240,50,1

1160

38

40

1000x298x800

1205x370x940

33

44

60/126/156

34/76/94

220-240,50,1(380,50,3)

1460

42

40

1000x298x800

1205x370x940

33

44

60/126/156

32/70/76

220-240,50,1(380,50,3)

2070

44

70

1350x298x800

1555x370x940

48

57

48/100/112

24/52/62

13000

20500

27300

Specification:

32000

Capacity

Performance
Electrical Data

220-240,50,1

2070

44

70

1350x298x800

1555x370x940

48

57

48/100/112

24/52/62

Model

32000
380,50,3

1460

42

40

1000x298x800

1205x370x940

33

44

60/126/156

32/70/76

32000
220-240,50,1(380,50,3)

2070

44

70

1350x298x800

1555x370x940

48

57

48/100/112

24/52/62

68000
380,50,3

2400

44

70

1350x298x800

1555x370x940

48

57

48/100/112

24/52/62

52000
380,50,3

2800

46

100

1350x320x800

1555x440x940

70

80

36/84/98

21/44/50

68000
380,50,3

4200

50

100

1350x450x760

1600x700x1010

96

106

21/42/42

107480

4400

50

100

1350x450x760

1600x700x1010

96

106

21/42/42

Cooling

Heating

Btu/h

Btu/h

MHB-18CR(N1)(N2)

18000

MHB-18HR(N1)(N2)

18000

MHB-24CR(N1)(N2)

24000

MHB-24HR(N1)(N2)

24000

MHB-30CRN1(N2)

30000

MHB-30HRN1(N2)

30000

MHB-36CR(N1)(N2)

36000

MHB-36HR(N1)(N2)

36000

MHB-48CR(N1)(N2)

48000

MHB-48HR(N1)(N2)

48000

MHB-60CR(N1)(N2)

60000

MHB-60HR(N1)(N2)

60000

Dimension

Weight

Oty'Per 20'/40'/40'HQ

Air Flow
Volume

Noise
Level

External Static
Pressure

Body

Package

Net

Gross

Indoor

Set

Voltage, Hz, Phase

m3/h

dB(A)

Pa

mm

mm

kg

kg

Pieces

Pieces

220-240,50,1

1400

38

70

1000x298x800

1205x370x940

36

43

60/126/156

34/76/94

220-240,50,1(380,50,3)

1550

42

70

1000x298x800

1205x370x940

38

45

60/126/156

32/70/76

220-240,50,1(380,50,3)

2150

44

100

1350x298x800

1555x370x940

48

57

48/100/112

24/52/62

220-240,50,1(380,50,3)

2150

44

100

1350x298x800

1555x370x940

48

57

48/100/112

24/52/62

380,50,3

2500

46

150

1350x320x800

1555x440x940

70

80

36/84/98

21/44/50

380,50,3

2850

46

150

1350x320x800

1555x440x940

70

80

36/84/98

21/44/50

20500

27300

32000

68000

7/14/15

76770
380,50,3

21

Dimension

Air Flow
Volume

Intake
The height of air
supply is 6.5m

52000

7/14/15
68000

22

High Statlc Pressure Duct


R410A

220-240V~,380V~,50Hz

R407C

Duct(slim)Type

220-240V~,380V~,50Hz

R22

R410A
R407C
R22

Ultra Thin ,Space Saving


The longest distance of
air supply is 14m
Induct Some Fresh Air

240mm

INDOOR UNIT
Outtake

Intake
The height of air
supply is 6.5m

Specification:
Performance

Capacity
Electrical Data
Model

Specification:
Capacity

Performance
Electrical Data

Model

Cooling
Btu/h

MHA-24CR(N1)(N2)

Heating
Btu/h

Voltage, Hz, Phase

m3

220-240,50,1(380,50,3)

External Static
Pressure

Body

Package

Net

Oty'Per 20'/40'/40'HQ

Gross

Indoor

Set

dB(A)

Pa

mm

mm

kg

kg

Pieces

Pieces

1650

44

196

850x380x660

1075x495x775

47

53

70/153/166

34/76/94

24000

MHA-30CRN1

30000
220-240,50,1(380,50,3)

2400

47

196

1200x380x666

1425x495x775

60

68

52/104/123

24/56/62

MHA-30HRN1

30000

MHA-30CRN2

30000
220-240,50,1

2400

47

196

1200x380x666

1425x495x775

60

68

52/104/123

24/56/62

MHA-30HRN2

30000

MHA-30CRN2

30000

MHA-30HRN2

30000

380,50,3

1650

44

196

850x380x660

1075x495x775

47

53

70/153/166

34/76/94

MHA-36CR(N1)(N2)

36000

MHA-36HR(N1)(N2)

36000

220-240,50,1(380,50,3)

2400

47

196

1200x380x666

1425x495x775

60

68

52/104/123

24/56/62

MHA-48CR(N1)(N2)

48000

MHA-48HR(N1)(N2)

48000

MHA-60CR(N1)(N2)

60000

MHA-60HR(N1)(N2)

60000

MHA-96CR(N1)(N2)

96000

27300

32000

32000

32000

38000
380,50,3

47

196

1200x380x666

1425x495x775

60

68

52/104/123

2900

47

196

1200x380x666

1425x495x775

60

68

52/104/123

107480

5000

50

196

1350x450x760

1600x700x1010

96

106

21/42/42

Heating

Btu/h

Btu/h

MTA2-09CR(N1)(N2)

9000

MTA2-09HR(N1)(N2)

9000

MTA2-12CR(N1)(N2)

12000

MTA2-12HR(N1)(N2)

12000

MTA2-18CR(N1)(N2)

18000

MTA2-18HR(N1)(N2)

18000

MTA2-24CR(N1)(N2)

24000

MTA2-24HR(N1)(N2)

24000

MTA2-30CRN1

30000

MTA2-30HRN1

30000

MTA2-30CRN2

30000

MTA2-30HRN2

30000

MTA2-30CRN2

30000

MTA2-30HRN2

30000

MTA2-36CR(N1)(N2)

36000

MTA2-36HR(N1)(N2)

36000

MTA2-48CR(N1)(N2)

48000

MTA2-48HR(N1)(N2)

48000

MTA2-60CR(N1)(N2)

60000

MTA2-60HR(N1)(N2)

60000

24/56/62

Dimension

Weight

Oty'Per 20'/40'/40'HQ

Air Flow
Volume

Noise
Level

External Static
Pressure

Body

Package

Net

Gross

Indoor

Set

Voltage, Hz, Phase

m3/h

dB(A)

Pa

mm

mm

kg

kg

Pieces

Pieces

220-240,50,1

500

38

50

1035x240x505

1130x340x655

20

24

121/252/280

70/145/162

220-240,50,1

650

38

50

1035x240x505

1130x340x655

20

24

121/252/280

70/145/162

220-240,50,1

1000

38

50

1210x240x505

1345x264x524

33

40

151/306/332

50/106/132

220-240,50,1(380,50,3)

1150

42

50

1410x240x505

1560x264x524

41

48

138/289/330

44/93/102

220-240,50,1(380,50,3)

2200

42

50

1610x245x510

1735x310x570

45

50

104/221/250

34/72/80

220-240,50,1

2200

42

50

1610x245x510

1735x310x570

45

50

104/221/250

34/72/80

380,50,3

1150

42

50

1410x240x505

1560x264x524

41

48

138/289/330

44/93/102

220-240,50,1(380,50,3)

2200

42

50

1610x245x510

1735x310x570

45

50

104/221/250

34/72/80

380,50,3

2200

42

50

1610x245x510

1735x310x570

45

50

104/221/250

27/57/58

380,50,3

2800

42

50

1610x245x510

1735x310x570

45

50

104/221/250

27/57/58

10000

13000

20500

27300

32000

32000

32000

38000

24/56/62

68000
380,50,3

96000

2900

52000
380,50,3

23

/h

Noise
Level

Weight

24000

MHA-24HR(N1)(N2)

MHA-96HR(N1)(N2)

Air Flow
Volume

Dimension

Cooling

52000

7/14/15
68000

24

Floor-standing

220-240V~,380V~,50Hz

Universal Outdoor Unit

220-240V~,380V~,50Hz

R410A

R407C
18000Btu/h

12000Btu/h

9000Btu/h

R22

R410A
R407C

72000Btu/h~96000Btu/h

R22

48000Btu/h~60000Btu/h
36000Btu/h

24000Btu/h~30000Btu/h

1 Strong air supply.

Features

2 Wide angle and long distance air supply.

1. The same capacity, the same outdoor unit.


2. Scroll compressor makes the EER much higher.

3 Easy installation.

3. Valve protection cover equipped.

4 Streamline stylish appearance.

4. Special cataphoric treatment guarantees to outdoor unit an extra long life span.

R410A

Universal Outdoor Unit

Specification:

Capacity
Capacity

Performance
Electrical Data

Model

Dimension

Cooling
Btu/h

MFA-96CR(N1)(N2)

96000

MFA-96HR(N1)(N2)

96000

Heating
Btu/h

Voltage, Hz, Phase


380,50,3

107480

Air Flow
Volume
m3

/h

4500

Noise
Level
dB(A)
44

Dimension
Body
mm
1200x1860x420

Weight

Package
mm
1382x2064x602

Net
kg
190

Oty'Per 20'/40'/40'HQ

Gross
kg
205

Indoor
Pieces
26/60/62

Set
Pieces
7/16/18

Cooling

Heating

Noise

Btu/h

Btu/h

MOU-12CDN1

12000

MOU-12HDN1

12000

MOU-18CDN1

18000

MOU-18HDN1

18000

MOU-24CDN1

24000

MOU-24HDN1

24000

MOU-30CDN1

30000

MOU-30HDN1

30000

MOU-36CDN1

36000

MOU-36HDN1

36000

MOU-48CDN1

48000

MOU-48HDN1

48000

MOU-60CDN1

60000

MOU-60HDN1

60000

Oty'Per 20'/40'/40'HQ

Body

Package

Net

Gross

Level

Voltage, Hz, Phase

mm

mm

kg

kg

dB(A)

220-240,50,1

760x590x285

890x655x360

37.5

41.5

43

123/255/344

220-240,50,1

845x695x335

965x847x395

52

57

48

68/144/216

220-240,50,1(380,50,3)

895x860x330

1000x985x410

75

85

52

62/128/130

101

106

220-240,50,1(380,50,3)

990x960x360

1120x1090x435

55

52/108/110

103

108

101

106
57

52/108/110

103

108

110

125

52

110

127

57

110

125

52

110

127

57

Pieces

13000

20500

27300

32000
220-240,50,1(380,50,3)

990x960x360

1120x1090x435

40000
380,50,3

940x1245x340

1020x1370x435

53000
380,50,3

25

Weight

Electrical Data
Model

75000

940x1245x340

30/61/62

1020x1370x435

30/61/62

26

Universal Outdoor Unit

220-240V~,380V~,50Hz

Universal Outdoor Unit

R410A

Capacity
Model

Cooling

Heating

Btu/h

Btu/h

MOU-12CN1

12000

MOU-12HN1

12000

MOU-18CN1

18000

MOU-18HN1

18000

MOU-24CN1

24000

MOU-24HN1

24000

MOU-30CN1

30000

MOU-30HN1

30000

MOU-36CN1

36000

MOU-36HN1

36000

MOU-48CN1

48000

MOU-48HN1

48000

MOU-60CN1

60000

MOU-60HN1

60000

Dimension
Electrical Data
Voltage, Hz, Phase
220-240,50,1

Weight

Noise

Body

Package

Net

Gross

Level

mm

mm

kg

kg

dB(A)

760x590x285

890x655x360

37.5

41.5

43

845x695x335

965x847x395

52

57

48

895x860x330

1000x985x410

75

85

52

220-240,50,1(380,50,3)

220-240,50,1(380,50,3)

990x960x360

990x960x360

940x1245x340

940x1245x340

106
108

101

106

103

108

110

125

52

110

127

57

110

125

52

110

127

57

55

57

1120x1090x435

1020x1370x435

53000
380,50,3

101
103

1120x1090x435

40000
380,50,3

1020x1370x435

75000

Btu/h

Btu/h

MOU-09CN2

9000

Dimension

MOU-09HN2

9000

MOU-12CN2

12000

MOU-12HN2

12000

MOU-18CN2

18000

MOU-18HN2

18000

MOU-24CN2

24000

MOU-24HN2

24000

MOU-30CN2

30000

MOU-30HN2

30000

MOU-36CN2

36000

MOU-36HN2

36000

MOU-48CN2

48000

MOU-48HN2

48000

MOU-60HN2

60000

Voltage, Hz, Phase


220-240,50,1

Weight

220-240,50,1

Gross

Level

mm

mm

kg

kg

dB(A)

890x655x360

845x695x335

965x847x395

36

39

42

1000x985x410

220-240,50,1(380,50,3)

990x960x360

37.5

41.5

52

57

75

85

43

48

52

220-240,50,1(380,50,3)

990x960x360

380,50,3

940x1245x340

75000

940x1245x340

106

103

108

101

106

103

108

110

125

52

110

127

57

110

125

52

55

1120x1090x435

12000

MOU-18CR

18000

MOU-18HR

18000

MOU-24CR

24000

MOU-24HR

24000

MOU-36CR

36000

MOU-36HR

36000

MOU-48CR

48000

MOU-48HR

48000

MOU-60CR

60000

MOU-60HR

60000

57

Gross

Level

mm

mm

kg

kg

dB(A)

Pieces

28

33
42

204/416/416

29

34
43

168/364/364

48

99/216/216

52

62/128/128

56

52/108/108

58

52/108/108

60

27/56/56

780x560x300

845x695x360

895x860x355

75000

62/128/130

52/108/110

52

56

53

57

62

64

64

66

1043x915x395

990x960x396

90

95

101

106

1120x1100x440

40000

53000

39
41

970x770x400

27300
220-240,50,1 (380,50,3)

34
36

910x575x335

20500
220-240,50,1 (380,50,3)

380,50,3

990x960x396

1120x1100x440

380,50,3

938x1255x400

1058x1370x435

90

95

101

106

107

118

114

135

Outdoor Units For MHA Series Indoor Units

R22
Dimension

Weight

Noise

Electrical Data
Model

Cooling

Heating

Btu/h

Btu/h

MHA-26CR

26000

MHA-26HR

26000

MHA-36CR

36000

MHA-36HR

36000

MHA-48CR

48000

MHA-48HR

48000

MHA-60CR

60000

MHA-60HR

60000

MHA-96CR

90000

Pieces

68/144/216

815x590x315

13000
220-240,50,1

Voltage, Hz, Phase


220-240,50,1 (380,50,3)

Package

Net

Gross

Level

mm

mm

kg

kg

dB(A)

Pieces

62

64
52

62/128/128

68

70
55

52/108/108

58

52/108/108

62

27/56/56

70

10/20/20

895x860x330

1043x915x395

990x960x360

990x960x360

938x1255x400

90000

997x1920x880

110

125

112

127

110

125

114

135

240

255

245

260

1058x1370x435

75000
380,50,3

125
127

1120x1090x435

53000
380,50,3

110
112

1120x1090x435

40000
380,50,3

1105x2120x1034

107480

52/108/110

30/61/62

1020x1370x435

Outdoor Units For 72K and 96K Indoor Units


30/61/62

110

127

57

Capacity

Dimension

Weight

Noise

Electrical Data
Model

Cooling

Heating

Btu/h

Btu/h

MOU-72CR(N1)(N2)

72000

MOU-72HR(N1)(N2)

72000

MOU-96CR(N1)(N2)

90000

MOU-96HR(N1)(N2)

90000

Voltage, Hz, Phase


380,50,3

Body

Package

mm

mm

997x1920x880

107480

997x1920x880

Net

1105x2120x1034

Oty'Per 20'/40'/40'HQ

Gross

Level
dB(A)

Pieces

70

10/20/20

70

10/20/20

kg

kg

240

255

245

260

240

255

245

260

1105x2120x1034

76770

380,50,3

27

Oty'Per 20'/40'/40'HQ

Body

27800
220-240,50,1 (380,50,3)

Oty'Per 20'/40'/40'HQ

Net

Capacity

123/255/344

Noise

Package

700x555x275

220-240,50,1

MHA-96HR

1020x1370x435

53000
380,50,3

101
1120x1090x435

40000

12000

MOU-12HR

Oty'Per 20'/40'/40'HQ

27300

32000

MOU-12CR

Voltage, Hz, Phase


220-240,50,1

52/108/110

176/348/364

Weight

Body

10000

52/108/110

20500
895x860x330

9000

62/128/130

13000
220-240,50,1

60000

Net

760x590x285

MOU-09HR
68/144/216

10000

220-240,50,1(380,50,3)

MOU-60HN2

Package

910x575x335

Btu/h

9000

Noise

Body

780x540x250

Btu/h
MOU-09CR

30/61/62

Electrical Data
Heating

Heating

123/255/344

R407C

Capacity
Cooling

Cooling

30/61/62

Universal Outdoor Unit


Model

Pieces

27300

32000

Dimension
Electrical Data

Model

20500
220-240,50,1(380,50,3)

R22

Capacity
Oty'Per 20'/40'/40'HQ

13000
220-240,50,1

Universal Outdoor Unit

28

[ D ] Series

Digital Scroll A/C System

Digital Scroll A/C System


R410A

Development of Digital Scroll System

R410A Digital Scroll Compressor

In 2002, the rollout of MDV-D Series has made Midea the leader of the industry.
In 2003, the launch of MDV-D Series has fully demonstrated the leading power of Midea. The MDV-D
Modulation System is a perfect application of Digital Scroll Technology. It simplifies the A/C system,
saves more energy, and guarantees a stable performance.

PWM Valve

What is Digital Scroll System

Discharge

Digital Scroll A/C System is a multi system


with Digital Scroll Compressor. Digital Scroll

Fixed Scroll

Compressor's refrigerant output is adjusted


and controlled by the variable volume mode.

Suction

This technology is the most advanced in


the industry.
Orbiting Scroll

The indoor units model line-up


R410A

Four-way cassette
(compact)

R407C

Four-way cassette

R22

One-way cassette
(compact)

One-way cassette

Duct

Duct
(compact)

Features
Widen the energy adjustment range: from 10%-100%.
Real stepless energy adjustment.
High static pressure duct

Ceiling & floor

Floor Standing

Concealed Floor Standing

Wall-mounted
(compact)

Wall-mounted

Long life span: PWM soloenoid valve can be used 40 billion times on average, equal to 30 years lifespan.
High efficiency and stability of the refrigerant compressed by applying the axial compliant sealing technology.

31

32

Digital Scroll A/C System

Operation Principle Of Digital Scroll Compressor

Advanced Oil Return Technology

The digital scroll compressor which utilizes the axial

The Digital Scroll Compressor is in the state of loading or unloading. In the loading state, the full speed

compliant sealing technology precisely adjust the axial

operation of the compressor motor ensures the refrigerant has enough power to bring the oil back to the

moving range of the stator scroll pan. And there is an

compressor. In the unloading state, there is no oil moving out of the compressor since there is no refrigerant

additional connecting by-pass between the suction inlet

output, the inertia of the refrigerant can also bring some oil back to the compressor.

and the pressure bore at the floating sealing point of


axial stator.

Combining the electronic control and the mechanical control, the oil level controller keeps an appropriate
oil level in the compressor crankcase. Equipped with alarm system, it is applicable to both low-pressure

When the PWM solenoid valve is open, the pressure in

& high pressure oil cycling system.

the pressure bore is released. The pressure in the


compression bore is higher than that top of the stator,
then the stator axis of the compressor will move upward

Accurate Temperature Control

a little. So high pressure bore and low pressure inlet is


connected and the unloading is achieved.

Compared with the traditional

Constant T emperature

central air conditioning system,

When the PWM solenoid valve is closed, two stators

Temperature control accuracy of MDV: *0.5*

MDV System can reach a 0.5

engaged. Then the airproof and loading is achieved. The

Temperature control accuracy of ordinary air conditioner: *3*

Degree Centigrade accuracy.

compressor can adjust the ratio of ONs to OFFs freely


to control the refrigerant output of the compressor.

No electromagnetic Disturbance
MDV Digital Scroll System causes no
electromagnetic disturbance, since the loading
and unloading of compressor are merely
mechanical movements. This special feature
makes the Digital Scroll System applicable to
telecommunication companies, power stations,
and all kinds of precise science labs.

(Time)
Electromagnetic Comparison Between Digital And Inverter

Inverter
5
7
M
11
W
13
17
19
E

EMC Standard

Digital

Long pipe, wide height difference

th
th
th
th
th
th

Digital scroll system is the only system that is free of oil separator
and oil recycling equipment. In the loading status, the speed
of the refrigerant is enough to move oil back to the compressor.In
the unloading status, no refrigerant pump out, no oil out of

compressor.

A
150m
50m
15m

150m the max.pipe length between indoor unit and outdoor unit
50m the max.height difference between indoor unit and outdoor unit
15m the max.height difference between indoor units

Precise Science Lab

33

Communication
Computer Lab

TV & Radio
Receiver Station
34

Digital Scroll A/C System


Cooling & Heating

Outdoor Unit

Outdoor Unit

Capacity(HP)

Model

Combination

Indoor unit connected

MDV-D252W/CS(N2)(N1)

13

10

MDV-D280W/CS(N2)(N1)

10

16

12

MDV-D335W/CS(N2)(N1)

12

16

14

MDV-D400W/CS(N2)(N1)

14

16

16

MDV-D450W/CS(N2)(N1)

16

20

18

MDV-D532W/CS(N2)(N1)

8+10

20

20

MDV-D560W/CS(N2)(N1)

10+10

20

22

MDV-D615W/CS(N2)(N1)

10+12

20

24

MDV-D680W/CS(N2)(N1)

10+14

20

26

MDV-D730W/CS(N2)(N1)

10+16

20

28

MDV-D785W/CS(N2)(N1)

12+16

20

30

MDV-D850W/CS(N2)(N1)

14+16

32

32

MDV-D900W/CS(N2)(N1)

16+16

32

34

MDV-D960W/CS(N2)(N1)

10x2+14

32

36

MDV-D1010W/CS(N2)(N1)

10x2+16

32

38

MDV-D1065W/CS(N2)(N1)

10+12+16

32

40

MDV-D1130W/CS(N2)(N1)

10+14+16

40

42

MDV-D1180W/CS(N2)(N1)

10+16x2

40

44

MDV-D1235W/CS(N2)(N1)

12+16x2

40

46

MDV-D1300W/CS(N2)(N1)

14+16x2

40

48

MDV-D1350W/CS(N2)(N1)

16x3

40

50

MDV-D1405W/CS(N2)(N1)

12x3+14

50

52

MDV-D1455W/CS(N2)(N1)

12x3+16

50

54

MDV-D1520W/CS(N2)(N1)

12x2+14+16

50

56

MDV-D1570W/CS(N2)(N1)

12x2+16x2

50

58

MDV-D1630W/CS(N2)(N1)

10+16x3

50

60

MDV-D1685W/CS(N2)(N1)

12+16x3

64

62

MDV-D1750W/CS(N2)(N1)

14+16x3

64

64

MDV-D1800W/CS(N2)(N1)

16x4

64

R410A

Model

Capacity
kW
Cooling
kW
Heating
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
Net
WxHxD
mm
Packing
WxHxD
mm
Weight
Net
kg
Gross
kg
Piping Connection
Max Length of pipe
Max Height Difference Between indoor units
Between indoor units and outdoor unit
SystemMatch Configuration

Max
Qty per 20'/40'/40'HQ

Pieces

IMDV-D252W/CSN1

IMDV-D280W/CSN1

IMDV-D335W/CSN1

IMDV-D400W/CSN1

IMDV-D450W/CSN1

25.2
27.0

28.0
31.5

33.5
35.0

40.0
43.0

45.0
47.0

380,50,3
10000
58

14000
60

980x1630x800
1040x1780x840

1380x1630x830
1440x1800x860

245
260

396
416

175
15
50
1-drive-13
14/28/28

1-drive-16
8/16/16

1-drive-20

R407C

Outdoor Unit

R22

Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
Net
WxHxD
mm
Packing
WxHxD
mm
Weight
Net
kg
Gross
kg
Piping Connection
Max Length of pipe
Max Height Difference Between indoor units
Between indoor units and outdoor unit
SystemMatch Configuration

Max
Qty per 20'/40'/40'HQ

Pieces

IMDV-D252W/CS(N2)

IMDV-D280W/CS(N2)

IMDV-D335W/CS(N2)

IMDV-D400W/CS(N2)

IMDV-D450W/CS(N2)

25.2
27.0

28.0
31.5

33.5
35.0

40.0
43.0

45.0
47.0

380,50,3
14000
60
1380x1630x830
1440x1800x860
327
347

396
416

150
15
50
1-drive-13
8/16/16

1-drive-16

1-drive-20

Remarks: 1.The above specifications are subject to change without prior notice for product improvement.
2.The noise levels given in the table reflect the levels in anechoic chamber.
35

36

Digital Scroll A/C System


Cooling & Heating

Indoor Unit
Unit:X100W

Outdoor Unit
Model
R410A

Capacity

Refrigerant
R410A

R407C

280

R22

Four-way cassette
(compact)

Model

IMDV-D100W/(S)N1

Capacity
Cooling
kW
10.0
Heating
kW
11.0
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
220-240,50,1(380,50,3)
Performance
Air Flow Volume
m3/h
5000
dB(A)
Noise Level
54
Dimension
mm
Net
WxHxD
990x960x360
mm
Packing
WxHxD
1120x1090x435
Weight
kg
Net
101
kg
Gross
106
Piping Connection
Max Length of pipe
60
Max Height Difference Between indoor units
8
Between indoor units and outdoor unit20

IMDV-D140W/SN1

IMDV-D280W/BSN1

14.0
16.0

28.0
31.5

6000
55

10000
58

940x1245x340
1058x1377x435

997x1920x880
1105x2120x1034

110
125

245
260

R407C

R22

R410A

R407C

R22

R410A

R407C

R22

R410A

R407C

R22

R410A

R407C

R22

R410A

R407C

R22

R410A

R407C

R22

R410A

R407C

R22

R410A

R407C

R22

R410A

R407C

R22

R410A

R407C

R22

R410A

R407C

R22

One-way cassette
(compact)

One-way cassette

175
15
50
1-drive-8
30/62/62

1-drive-6
50/100/100

Pieces

Four-way cassette

380,50,3

SystemMatch Configuration

Max
Qty per 20'/40'/40'HQ

R410A

Low Static Pressure


Duct

1-drive-16
10/20/20
Duct

Outdoor Unit
R407C

High static pressure duct

R22

Model

IMDV-D100W/SN2

IMDV-D100W/(N2)

Capacity
kW
Cooling
10.0
kW
Heating
11.0
Electrical Data
V~,Hz,Ph
Voltage,Frequence,Phase
220-240,50,1
380,50,3
Performance
m3/h
Air Flow Volume
5000
Noise Level
dB(A)
54
Dimension
Net
WxHxD
mm
990x960x360
Packing
WxHxD
mm
1120x1090x435
Weight
Net
kg
101
Gross
kg
106
Piping Connection
Max Length of pipe
60
Max Height Difference Between indoor units
8
Between indoor units and
20 outdoor unit

IMDV-D140W/S(N2)

IMDV-D280W/BS(N2)

IMDV-D560W/BS(N2)

IMDV-D840W/BS(N2)

14.0
16.0

28.0
31.5

56.0
64.0

84.0
95.0
Floor Standing

380,50,3
5000
54

10000
58

20000
60

30000
62

997x1920x880
1105x2120x1034

1992x1920x880
2110x2120x1034

2987x1920x880
3105x2120x1034

245
260

520
525

780
785

Concealed Floor Standing

Ceiling & floor

150
15
50

SystemMatch Configuration

Max
Qty per 20'/40'/40'HQ

High static pressure duct

Wall-mounted

Pieces

1-drive-6
50/100/100

1-drive-8

Remarks: 1.The above specifications are subject to change without prior notice for product improvement.
2.The noise levels given in the table reflect the levels in anechoic chamber.

1-drive-16
10/20/20

1-drive-20
4/10/10

1-drive-32
2/6/6
Wall-mounted
(compact)

The Digital Scroll A/C System and Inverter Commercial A/C System have the same specification of indoor unit.

37

38

Digital Scroll A/C System


Cooling & Heating

Indoor Unit (Q4)


Model

Capacity
kW
Cooling
kW
Heating
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
Net
WxHxD Body
mm
Panel
mm
Packing
WxHxD Body
mm
Panel
mm
Weight
Net
Body/Panel kg
Gross
Body/Panel kg
Qty per 20'/40'/40'HQ Indoor Pieces

Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
Net
WxHxD Body
mm
Panel
mm
Packing
WxHxD Body
mm
Panel
mm
Weight
Net
Body/Panel kg
Gross
Body/Panel kg
Qty per 20'/40'/40'HQ Indoor Pieces

Indoor Unit (T3)

IMDV-D28Q4/ N1-A
IMDV-D28Q4/(N2)-A

IMDV-D36Q4/ N1-A
IMDV-D36Q4/(N2)-A

IMDV-D45Q4/ N1-A
IMDV-D45Q4/(N2)-A

IMDV-D28Q4/(N2)

IMDV-D36Q4/(N2)

2.8
3.2

3.6
4.0

4.5
5.0

2.8
3.2

3.6
4.0

220-240,50,1
780
36

870

580x254x580
650x30x650
795x340x745
715x115x715

840x240x840
950x40x950
955x255x955
1030x145x1030

22/3
29/5
110/245/252

25/6
32/11
72/145/168

IMDV-D45Q4/(N2)

IMDV-D56Q4/N1
IMDV-D56Q4/(N2)

IMDV-D71Q4/N1
IMDV-D71Q4/(N2)

IMDV-D80Q4/N1
IMDV-D80Q4/(N2)

IMDV-D90Q4/N1
IMDV-D90Q4/(N2)

IMDV-D112Q4/N1
IMDV-D112Q4/(N2)

4.5
5.0

5.6
6.3

7.1
8.0

8.0
9.0

9.0
10.0

11.2
12.5

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
Net
WxHxD Body
mm
Panel
mm
Packing
WxHxD Body
mm
Panel
mm
Weight
Net
Body/Panel kg
Gross
Body/Panel kg
Qty per 20'/40'/40'HQ Indoor
Pieces

1050
38

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Pa
External static pressure
dB(A)
Noise Level
Dimension
mm
Net
WxHxD
mm
Packing
WxHxD
Weight
kg
Net
kg
Gross
Qty per 20'/40'/40'HQ Indoor Pieces

1600
44

42

840x240x840
950x40x950
955x255x955
1030x145x1030

840x310x840

28/6
34/11
72/145/168

35/6
41/11
56/126/144

955x325x955

IMDV-D28Q1/BN1
IMDV-D28Q1/B(N2)

IMDV-D36Q1/BN1
IMDV-D36Q1/B(N2)

IMDV-D45Q1/BN1
IMDV-D45Q1/B(N2)

IMDV-D56Q1/BN1
IMDV-D56Q1/B(N2)

IMDV-D71Q1/BN1
IMDV-D71Q1/B(N2)
Model

2.8
3.2

3.6
4.0

4.5
5.0

500
36

780
42

5.6
6.3

7.1
8.0

220-240,50,1
470
35
850x235x400
1050x18x470
1080x310x460
1120x172x540

1200x198x655
1420x10x755
1380x265x775
1500x110x870

23/4
27/7
115/238/268

31/9
38/12
69/145/165

1080

IMDV-D22T3/N1
IMDV-D22T3/(N2)

IMDV-D28T3/N1
IMDV-D28T3/(N2)

IMDV-D36T3/N1
IMDV-D36T3/(N2)

IMDV-D45T3/N1
IMDV-D45T3/(N2)

IMDV-D56T3/N1
IMDV-D56T3/(N2)

2.2
2.6

2.8
3.2

3.6
4.0

4.5
5.0

5.6
6.3

220-240,50,1
950

580
10
34

37

35

955x210x385
1114x277x469

1301x210x385
1459x277x469

15
19
214/437/480

18
22
164/315/391

Indoor Unit (T2)


Model

Remarks: 1.The above specifications are subject to change without prior notice for product improvement.
2.The noise levels given in the table reflect the levels in anechoic chamber.
39

Capacity
kW
Cooling
kW
Heating
Electrical Data
Voltage,Frequence,Phase V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Pa
External static pressure
dB(A)
Noise Level
Dimension
mm
Net
WxHxD
mm
Packing
WxHxD
Weight
kg
Net
kg
Gross
Qty per 20'/40'/40'HQ Indoor Pieces

220-240,50,1

Indoor Unit (Q1)


Model

Model

Capacity
kW
Cooling
kW
Heating
Electrical Data
Voltage,Frequence,Phase V~,Hz,Ph
Performance
Air Flow Volume
m3/h
External static pressure
Pa
Noise Level
dB(A)
Dimension
Net
WxHxD
mm
Packing
WxHxD
mm
Weight
Net
kg
Gross
kg
Qty per 20'/40'/40'HQ Indoor Pieces

IMDV-D22T2/N1
IMDV-D22T2/(N2)

IMDV-D28T2/N1
IMDV-D28T2/(N2)

2.2
2.6

IMDV-D36T2/N1
IMDV-D36T2/(N2)

IMDV-D45T2/N1-A3
IMDV-D45T2/(N2)-A3

3.6
4.0

2.8
3.2

IMDV-D56T2/N1-A3
IMDV-D56T2/(N2)-A3

4.5
5.0

5.6
6.3

220-240,50,1
750
40
34

1160
35

38

800x320x550
930x420x755

1000x298x800
1200x370x930

26
34
61/134/164

46
54
60/140/164

IMDV-D71T2/N1-A3
IMDV-D71T2/(N2)-A3

IMDV-D80T2/N1-A3
IMDV-D80T2/(N2)-A3

IMDV-D90T2/N1-A3
IMDV-D90T2/(N2)-A3

IMDV-D112T2/N1-A3
IMDV-D112T2/(N2)-A3

IMDV-D140T2/N1-A3
IMDV-D140T2/(N2)-A3

IMDV-D280T2/N1
IMDV-D280T2/(N2)

7.1
8.0

8.0
9.0

9.0
10.0

11.2
12.5

14.0
16.0

28.0
31.0

2400

4400
96
49

220-240,50,1
1460
40
42

2070
70
44

1000x298x800
1200x370x930

1350x298x800
1555x370x930

1350x450x760
1600x700x1010

47
55
60/140/164

60
70
48/100/112

99
109
22/48/48

46

Remarks: 1.The above specifications are subject to change without prior notice for product improvement.
2.The noise levels given in the table reflect the levels in anechoic chamber.
40

Digital Scroll A/C System


Cooling & Heating

Indoor Unit (T1)


Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
External static pressure
Pa
Noise Level
dB(A)
Dimension
Net
WxHxD
mm
Packing
WxHxD
mm
Weight
Net
kg
Gross
kg
Qty per 20'/40'/40'HQ Indoor Pieces

IMDV-D45T1/N1-A3 IMDV-D56T1/N1-A3 IMDV-D71T1/N1-A3 IMDV-D80T1/N1-A3 IMDV-D90T1/N1-A3 IMDV-D112T1/N1-A3 IMDV-D140T1/N1-A


IMDV-D45T1/(N2)-A3 IMDV-D56T1/(N2)-A3 IMDV-D71T1/(N2)-A3 IMDV-D80T1/(N2)-A3 IMDV-D90T1/(N2)-A3 IMDV-D112T1/(N2)-A3 IMDV-D140T1/(N2)-A
4.5
5.0

5.6
6.3

8.0
9.0

7.1
8.0

9.0
10.0

14.0
16.0

11.2
12.5

220-240,50,1
2150
100
44

2500
150
46

1350x298x800
1555x370x930

1350x320x800
1555x440x930

50
59
48/100/112

72
82
36/84/98

1550

1400
70
38

42

1000x298x800
1200x370x930
40
47

38
45
60/140/164

Cooling & Heating

Indoor Unit (F)


Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
Net
WxHxD
mm
Packing
WxHxD
mm
Weight
Net
kg
Gross
kg
Qty per 20'/40'/40'HQ Indoor Pieces

IMDV-D22F/N1
IMDV-D22F/(N2)

IMDV-D28F/N1
IMDV-D28F/(N2)

IMDV-D36F/N1
IMDV-D36F/(N2)

IMDV-D45F/N1
IMDV-D45F/(N2)

IMDV-D56F/N1
IMDV-D56F/(N2)

IMDV-D71F/N1
IMDV-D71F/(N2)

IMDV-D80F/N1
IMDV-D80F/(N2)

2.2
2.6

2.8
3.2

3.6
4.0

4.5
5.0

5.6
6.3

7.1
8.0

8.0
9.0

420
35

490

620
37

850
39

950
40

1050
42

1000x626x220
1145x810x285

1200x626x220
1335x810x285

1500x626x220
1645x810x285

38
42
80/168/252

43
47
68/138/216

55
60
54/114/171

220-240,50,1

Indoor Unit (T1)


Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
External static pressure
Pa
Noise Level
dB(A)
Dimension
Net
WxHxD
mm
Packing
WxHxD
mm
Weight
Net
kg
Gross
kg
Qty per 20'/40'/40'HQ Indoor Pieces

IMDV-D71T1/N1
IMDV-D71T1/(N2)

IMDV-D80T1/N1
IMDV-D80T1/(N2)

IMDV-D90T1/N1
IMDV-D90T1/(N2)

IMDV-D112T1/N1
IMDV-D112T1/(N2)

IMDV-D140T1/N1
IMDV-D140T1/(N2)

IMDV-D280T1/N1
IMDV-D280T1/(N2)

7.1
8.0

8.0
9.0

9.0
10.0

11.2
12.5

14.0
16.0

28.0
31.5

220-240,50,1

Model

1300
196
44

2200

5000

47

50

850x380x660
1075x473x775

1200x380x660
1425x473x775

1350x450x760
1600x700x1010

49
55
81/166/166

62
70
60/123/123

98
108
22/48/48

Indoor Unit (DL)


Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
V~,Hz,Ph
Voltage,Frequence,Phase
Performance
Air Flow Volume
m3/h
dB(A)
Noise Level
Dimension
mm
Net
WxHxD
mm
Packing
WxHxD
Weight
kg
Net
kg
Gross
Qty per 20'/40'/40'HQ Indoor Pieces

IMDV-D36DL/N1-B IMDV-D45DL/N1-B IMDV-D56DL/N1-B IMDV-D71DL/N1-B IMDV-D80DL/N1-B IMDV-D90DL/N1-B IMDV-D112DL/N1-B IMDV-D140DL/N1-B


IMDV-D36DL/(N2)-B IMDV-D45DL/(N2)-B IMDV-D56DL/(N2)-B IMDV-D71DL/(N2)-B IMDV-D80DL/(N2)-B IMDV-D90DL/(N2)-B IMDV-D112DL/(N2)-B IMDV-D140DL/(N2)-B
3.6
4.0

Indoor Unit (F)

4.5
5.0

5.6
6.3

7.1
8.0

8.0
9.0

9.0
10.0

11.2
12.5

14.0
16.0

1000
40

1200
41

1400

1800
42

2000

38

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
dB(A)
Noise Level
Dimension
mm
Net
WxHxD
mm
Packing
WxHxD
Weight
kg
Net
kg
Gross
Qty per 20'/40'/40'HQ Indoor Pieces

IMDV-D22F/N1-A IMDV-D28F/N1-A IMDV-D36F/N1-A IMDV-D45F/N1-A IMDV-D56F/N1-A IMDV-D71F/N1-A IMDV-D80F/N1-A


IMDV-D22F/(N2)-A IMDV-D28F/(N2)-A IMDV-D36F/(N2)-A IMDV-D45F/(N2)-A IMDV-D56F/(N2)-A IMDV-D71F/(N2)-A IMDV-D80F/(N2)-A
2.2
2.6

3.6
4.0

4.5
5.0

5.6
6.3

7.1
8.0

8.0
9.0

420
35

490

620
37

850
39

950
40

1050
42

750x545x212
835x630x265

950x545x212
1035x630x265

1250x545x212
1335x630x265

35
39
91/182/282

39
44
73/155/236

50
55
59/134/192

2.8
3.2

220-240,50,1

Remarks: 1.The above specifications are subject to change without prior notice for product improvement.
2.The noise levels given in the table reflect the levels in anechoic chamber.

220-240,50,1
800
36
995x660x198
1080x740x290

1285x660x198
1365x740x290

1670x680x240
1760x760x330

30
37
128/270/300

34
42
99/203/228

52
62
72/153/168

Remarks: 1.The above specifications are subject to change without prior notice for product improvement.
2.The noise levels given in the table reflect the levels in anechoic chamber.
41

42

Digital Scroll A/C System


Cooling & Heating

[ V ] Series
Indoor Unit (G)
Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
Net
WxHxD
mm
Packing
WxHxD
mm
Weight
Net
kg
Gross
kg
Qty per 20'/40'/40'HQ Indoor Pieces

IMDV-D22G/N1-E
IMDV-D22G/(N2)-E

IMDV-D28G/N1-E
IMDV-D28G/(N2)-E

IMDV-D36G/N1-E
IMDV-D36G/(N2)-E

IMDV-D45G/N1-E
IMDV-D45G/(N2)-E

IMDV-D56G/N1-E
IMDV-D56G/(N2)-E

2.2
2.5

2.8
3.2

3.6
4.0

4.5
5.0

5.6
6.3

220-240,50,1
580
34

850
37

790x265x195
875x375x285

920x292x225
1015x368x295

9
11
312/668/780

13
15
288/578/653

Indoor Unit (G)


Model

Capacity
kW
Cooling
kW
Heating
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
Net
WxHxD
mm
Packing
WxHxD
mm
Weight
Net
kg
Gross
kg
Qty per 20'/40'/40'HQ Indoor Pieces

IMDV-D22G/N1-A
IMDV-D22G/(N2)-A

IMDV-D28G/N1-A
IMDV-D28G/(N2)-A

IMDV-D36G/N1-A
IMDV-D36G/(N2)-A

IMDV-D45G/N1-A
IMDV-D45G/(N2)-A

IMDV-D56G/N1-A
IMDV-D56G/(N2)-A

2.2
2.5

2.8
3.2

3.6
4.0

4.5
5.0

5.6
6.3

220-240,50,1
560
36

670
46

880x275x198
1000x420x295

1080x330x222
1315x445x320

11
14
252/512/576

17
23
151/324/384

Remarks: 1.The above specifications are subject to change without prior notice for product improvement.
2.The noise levels given in the table reflect the levels in anechoic chamber.

43

Inverter A/C System(DC/AC)

Inverter A/C System


Energy Saving
The traditional central air
conditioner system can only
supply the same cooling &

Flexible Piping & Control Solutions


Power Saving Up to 40%

Compressor Frequency: 30~120Hz

heating capacity to all its


indoor units, while the MDV
Inverter Commercial A/C
System can supply exact
cooling & heating capacity to
each individual indoor unit

Multi-level Energy Adjustment

135%

27 levels adjustment

10%

MDV-V

2 levels adjustment
Traditional
central Aircon

MDV-V

Traditional central Aircon

The advanced BUS


communication technology
(Plug & Play) makes the
connection of indoor and
outdoor units flexible.
As a modular Multi System,
MDV System has excellent
expansability.

BUS communication

(Maximum length
of piping: 125m)
(Height difference
between indoor and
outdoor unit: 50m)
(Height difference
between indoor
units: 30m)

Plug & Play


Plug & Play

according to the independent


indoor unit control device.

Flexible Piping

1-drive-more system

Flexible 1-drive-more system

1 outdoor unit can drive 16 indoor units

Intellectualized Temperature Control


This temperature control is
sensitive enough to get the
information about the
temperature in the room and
adjust it automatically.

Intelligent Automatic T emperature Control

Easier installation, easier maintanance


Normal Cooling

Rapid Adjustment

MDV Inverter Commercial A/C System is a direct expansion system, and it simplifies the complicated installation
process and makes the maintenance easy.
Advanced self malfunction detecting, doesn't need professional person for maintenance, lower installation and
maintenance cost.

Set temperature 23

Set temperature 23

Compact indoor and outdoor design, saves installation space and lowers the installation cost. Parallel connection
modular design.

Compressor parallel connection technology


Inverter compressor and constant compressor are parallel connection in the outdoor unit. In part load
mode only the inverter compressor runs; in full load mode, all the compressors run. So the inverter
compressor will mostly run at the middle frequency range (40-90Hz). Because at the middle frequency

Less floor height

H1>H2

range the inverter compressor has highest efficiency and lowest noise and vibration, the A/C with Compressor
parallel connection technology has higher efficiency and lower noise and vibration than the A/C has only
one inverter compressor. Also it has wide capacity adjusted range (15-110%) than the A/C has only one
inverter compressor, so it has higher SEER.

45

46

Inverter A/C System


Cooling & Heating

Outdoor Unit

R410A

Outdoor Unit

Capacity(HP)

Model

Combination

Indoor unit connected

MDV-V252W/CS(N1)

13

10

MDV-V280W/CS(N1)

10

16

12

MDV-V335W/CS(N1)

12

16

14

MDV-V400W/CS(N1)

14

16

16

MDV-V450W/CS(N1)

16

20

18

MDV-V532W/CS(N1)

8+10

20

20

MDV-V560W/CS(N1)

10+10

20

22

MDV-V615W/CS(N1)

10+12

20

24

MDV-V680W/CS(N1)

10+14

20

26

MDV-V730W/CS(N1)

10+16

20

28

MDV-V785W/CS(N1)

12+16

20

30

MDV-V850W/CS(N1)

14+16

32

32

MDV-V900W/CS(N1)

16+16

32

34

MDV-V960W/CS(N1)

10x2+14

32

36

MDV-V1010W/CS(N1)

10x2+16

32

38

MDV-V1065W/CS(N1)

10+12+16

32

40

MDV-V1130W/CS(N1)

10+14+16

40

42

MDV-V1180W/CS(N1)

10+16x2

40

44

MDV-V1235W/CS(N1)

12+16x2

40

46

MDV-V1300W/CS(N1)

14+16x2

40

48

MDV-V1350W/CS(N1)

16x3

40

50

MDV-V1405W/CS(N1)

12x3+14

50

52

MDV-V1455W/CS(N1)

12x3+16

50

54

MDV-V1520W/CS(N1)

12x2+14+16

50

56

MDV-V1570W/CS(N1)

12x2+16x2

50

58

MDV-V1630W/CS(N1)

10+16x3

50

60

MDV-V1685W/CS(N1)

12+16x3

64

62

MDV-V1750W/CS(N1)

14+16x3

64

64

MDV-V1800W/CS(N1)

16x4

64

Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
Net
WxHxD
mm
Packing
WxHxD
mm
Weight
Net
kg
Gross
kg
Piping Connection
Max Length of pipe
m
Max Height Difference Between indoor units
m
m
Between indoor units and outdoor unit
SystemMatch Configuration

Max
Qty per 20'/40'/40'HQ

Pieces

IMDV-V252W/CSN1

IMDV-V280W/CSN1

25.2
27.0

28.0
31.5

IMDV-V335W/CSN1
33.5
35.0

40.0
43.0

IMDV-V450W/CSN1
45.0
47.0

380,50,3
10000
58

14000
60

980x1630x800
1040x1780x840

1380x1630x830
1440x1800x860

245
260

396
416

175
15
50
1-drive-13
14/28/28

1-drive-16

8/16/16

Outdoor Unit

1-drive-20

R22

Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
mm
Net
WxHxD
mm
Packing
WxHxD
Weight
Net
kg
Gross
kg
Piping Connection
Max Length of pipe
m
Max Height Difference Between indoor units
m
Between indoor units and outdoor unit
m
SystemMatch Configuration

Max
Qty per 20'/40'/40'HQ

IMDV-V400W/CSN1

Pieces

IMDV-V252W/CS
25.2
27.0

IMDV-V280W/CS

IMDV-V335W/CS

IMDV-V400W/CS

IMDV-V450W/CS

33.5
35.0

40.0
43.0

45.0
47.0

28.0
31.5

380,50,3
14000
60
1380x1630x830
1440x1800x860
327
347

396
416

150
15
50
1-drive-13
8/16/16

1-drive-16

1-drive-20

Remarks: 1.The above specifications are subject to change without prior notice for product improvement.
2.The noise levels given in the table reflect the levels in anechoic chamber.
47

48

Inverter A/C System


Cooling & Heating

R410A

Outdoor Unit

Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
V~,Hz,Ph
Voltage,Frequence,Phase
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
mm
Net
WxHxD
mm
Packing
WxHxD
Weight
kg
Net
kg
Gross
Piping Connection
m
Max Length of pipe
m
Max Height Difference Between indoor units
m
Between indoor units and outdoor unit

IMDV-V120W/(S)N1

IMDV-V140W/(S)N1

IMDV-V160W/(S)N1

IMDV-V180W/(S)N1

12.0
14.0

14.0
16.5

16.0
18.5

18.0
21.0

220-240,50,1(380,50,3)
6000
54

8600
56

940x1245x340
1060x1370x440

800x1600x620
930x1727x760

135
150

201
217

50
8
20

SystemMatch Configuration

Max
Qty per 20'/40'/40'HQ

Pieces

1-drive-6
30/62/62

Outdoor Unit

1-drive-8

1-drive-10
25/52/52

R22

Model

Capacity
kW
Cooling
kW
Heating
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
mm
Net
WxHxD
mm
Packing
WxHxD
Weight
Net
kg
Gross
kg
Piping Connection
Max Length of pipe
m
Max Height Difference Between indoor units
m
Between indoor units and outdoor unit
m
SystemMatch Configuration

Max
Qty per 20'/40'/40'HQ

Pieces

IMDV-V80W

IMDV-V120W(/S)

IMDV-V140W(/S)

IMDV-V160W(/S)

IMDV-V180W(/S)

8.0
9.6

12.0
14.0

14.0
16.5

16.0
18.5

18.0
21.0

220-240,50,1

220-240,50,1(380,50,3)

5000
52

6000
54

8600
56

895x860x330
1030x910x430

940x1245x340
1060x1370x440

800x1600x620
930x1727x760

81
90

135
150

201
217

35
5
10

50
8
20

1-drive-3
60/122/122

1-drive-6
30/62/62

Remarks: 1.The above specifications are subject to change without prior notice for product improvement.
2.The noise levels given in the table reflect the levels in anechoic chamber.
49

[ M ] Series

1-drive-8

1-drive-10
25/52/52

Multi Variable A/C System

Multi Variable A/C System


Cooling & Heating

R407C

Outdoor Unit

R22
Four-cassette type(6kW)
Duct type(slim)(6kW)
Indoor units

Model

12kW

Four-cassette type(12.5kW)

Duct type(13kW)

Indoor units

High static pressure


Duct type(13kW)

Capacity
kW
Cooling
kW
Heating
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
Air Flow Volume
m3/h
Noise Level
dB(A)
Dimension
Net
WxHxD
mm
mm
Packing
WxHxD
Weight
Net
kg
Gross
kg
Piping Connection
m
Max Length of pipe
m
Max Height Difference Between indoor units
m
Between indoor units and outdoor unit

IMDV-M120W/(N2)

IMDV-M250(260)W/S(N2)

12.0
13.0

25.0(26.0)
27.0(28.0)

220~240,50,1

380,50,3

6000
56

10000
60

940x1245x340
1058x1377x435

1290x1540x750
1360x1720x820

110
125

295
310

20
10
15

70
20
20

1-drive-2
30/61/62

1-drive-2
8/16/16

SystemMatch Configuration

Max
Qty per 20'/40'/40'HQ

Pieces

26kW

R407C
R22
*

Long pipe running, enough vertical fall, free designing style


Pipe length between indoor unit and outdoor unit reaches to 70m(10HP system),
the vertical fall between indoor unit and outdoor unit is 20m(10HP system), these
two adventages make the installation position of outdoor unit flexible.

Be reliable, excellent performance


Multi-compressor system, no influence occur between each other.

Multiform controlling fashion, be convenient for operating


Available for wire controlling, remote controlling and central controlling in group, it's
convenient for operating.

Be suitable, creates a better life


Many kinds of indoor untis are available, gives you much more ideas about the
situation, cooling and heating simultaneously, satisfies all your needs.

51

Indoor Unit
Model

Capacity
Cooling
kW
Heating
kW
Electrical Data
Voltage,Frequence,Phase
V~,Hz,Ph
Performance
m3/h
Air Flow Volume
Pa
External static pressure
dB(A)
Noise Level
Dimension
Net
WxHxD Body
mm
Panel
mm
Packing
WxHxD Body
mm
Panel
mm
Weight
Net
Body/Panel kg
Gross
Body/Panel kg
Qty per 20'/40'/40'HQ Indoor Pieces

IMDV-M60Q4(N2)

IMDV-M60T2/-A(N2)

IMDV-M125Q4(N2)

6.0
6.5

12.5
13.0

220-240,50,1

220-240,50,1

1020

IMDV-M130T2(N2)

IMDV-M130T1(N2)

13.0
14.0

13.0
14.0

2400
100
46

2900
196
47

1400
30
38

1800

840x240x840
950x40x950
955x260x955
1030x145x1030

1410x240x496

840x310x840
950x40x950
955x325x955
1030x145x1030

1350x320x800

1200x380x660

1555x370x940

1425x480x775

36/6
43/11
72/150/168

36
40
84/172/199

40/6
47/11
48/102/122

72
80
48/100/112

63
70
48/96/120

40

1560x340x570

44

Remarks: 1.The above specifications are subject to change without prior notice for product improvement.
2.The noise levels given in the table reflect the levels in anechoic chamber.

52

DC Inverter Multi

220-240V~,50Hz

R410A
M2OA-18HRDN1

[ H ] Series
R410A
M3OA-27HRDN1

R410A

Multi System
M4OA-27HRDN1

One outdoor unit can drive 4 free-matched indoor units at most.


13 Types of Indoor Unit Combinations
One Unit

Two Units

22 Types of Indoor Unit Combinations


One Unit

Two Units

Three Units

7+7

9+9

12 + 12

7+7

9+9

12 + 12

7+7+7

7+9+9

7+9

9 + 12

12 + 18

7+9

9 + 12

12 + 18

7+7+9

7 + 9 + 12

12

7 + 12

9 + 18

12

7 + 12

9 + 18

7 + 7 + 12

7 + 12 + 12

18

7 + 18

18

7 + 18

7 + 7 + 18

9+9+9

9 + 9 + 12

38 Types of Indoor Unit Combinations


One Unit

Two Units

Three Units

Four Units

7+7

9+9

12 + 12

7+7+7

7+9+9

7 + 12 + 18

9 + 12 + 12

7+7+7+7

7+7+9+9

9+9+9+9

7+ 9

9 + 12

12 + 18

7+7+9

7 + 9 + 12

9+9+9

9 + 12 + 18

7+7+7+9

7 + 7 + 9 + 12

9 + 9 + 9 + 12

12

7 + 12

9 + 18

7 + 7 + 12

7 + 9 + 18

9 + 9 + 12

12 + 12 + 12

7 + 7 + 7 + 12

7+9+9+9

18

7 + 18

7 + 7 + 18

7 + 12 + 12

9 + 9 + 18

7 + 7 + 7 + 18

7 + 9 + 9 + 12

54

DC Inverter Multi

220-240V~,50Hz

AC Inverter Multi

220-240V~,50Hz

R410A
Cooling & Heating

M2OA-18HRIN1

Indoor unit
Model

Capacity
Cooling/Heating
Performance
Dimension (WxHxD)
Packing (WxHxD)
Net/Gross Weight

Air flow volume


Indoor noise level
Liquid side/Gas side

Body
Panel
Body
Panel
Body
Panel

IMSHI-07HRIN1

IMSHI-09HRIN1

IMSHI-12HRIN1

IMST2I-07HRIN1

IMST2I-09HRIN1

Btu/h

7000/9000

9000/11000

12000/13500

7000/9000

9000/11000

mm
mm
mm
mm
kg
kg
3
m /h
dB(A)
mm

750x250x205

815x280x215

955x210x385

830x336x285

915x360x290

1114x277x469

8/10

10/12

15/19

600
33
6.35/ 12.7

480
34
6.35/ 9.53

Model

Capacity
Cooling/Heating
Performance
Dimension (WxHxD)
Packing (WxHxD)
Net/Gross Weight

Air flow volume


Indoor noise level
Liquid side/Gas side

Body
Panel
Body
Panel
Body
Panel

R410A
M3OA-27HRIN1

500
30
6.35/ 9.53

520
32

550

IMST2I-12HRIN1

IMST2I-18HRIN1

IMSQ4I-07HRIN1

IMSQ4I-09HRIN1

IMSQ4I-12HRIN1

IMSQ4I-18HRIN1

Btu/h

12000/15000

18000/20500

7000/90000

9000/11000

12000/15000

18000/20500

mm
mm
mm
mm
kg
kg
m3/h
dB(A)
mm

955x210x385

1301x210x385

1114x277x469

1459x277x469

15/19

18/22

580
35
6.35/ 12.7

660
40

580x254x580
650x30x650
750x340x750
715x115x715
21/30
3/5
550
32
6.35/ 9.53

R410A
M4OA-27HRIN1

600
33

680
35
6.35/ 12.7

860
40

Outdoor unit
Model

Power
Voltage,Frequency,Phase
Capacity
Cooling
Heating
Electrical Data
Power Input

V~,Hz,Ph
min.-nom.-max Btu/h
min.-nom.-max
kW
min.-nom.-max Btu/h
min.-nom.-max
kW

IM2OA-18HRDN1

IM3OA-27HRDN1

IM4OA-27HRDN1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

5459-18084-22519
1.6-5.3-6.6
7848-23543-25249
2.3-6.9-7.4

9383-26614-31732
2.75-7.8-9.3
10714-30708-36850
3.14-9.0-10.8

9622-27296-32755
2.82-8.0-9.6
11055-31732-38214
3.24-9.3-11.2

0.44-1.58-2.28
0.77-2.39-3.49
Cooling min.-nom.-max
kW
Heating min.-nom.-max
0.58-1.88-2.47
0.82-2.54-3.66
kW
Operating Current Cooling min.-nom.-max
2.08-7.48-10.80
3.65-11.32-16.52
A
Heating min.-nom.-max
A
2.53-8.20-10.78
3.58-11.08-15.97
Performance
EER-Energy Class
W/W
3.26-A
3.35-A
COP-Energy Class
W/W
3.68-A
3.54-B
Dimension (WxHxD)
845x695x335
845x695x335
mm
Packing (WxHxD)
975x772x405
975x772x405
mm
Net/Gross Weight
71/74
72/76
kg
3
Outdoor air flow
2200
2400
m /h
Outdoor noise level
dB(A)
53
55
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.

55

0.81-2.52-3.55
0.86-2.7-3.86
3.84-11.93-16.81
4.07-12.78-18.28
3.17-B
3.44-B
895x860x330
1043x915x395
80/84
3500
57

One outdoor unit can drive 4 free-matched indoor units at most.


13 Types of Indoor Unit Combinations
One Unit

Two Units

22 Types of Indoor Unit Combinations


One Unit

Two Units

Three Units

7+7

9+9

12 + 12

7+7

9+9

12 + 12

7+7+7

7+9+9

7+9

9 + 12

12 + 18

7+9

9 + 12

12 + 18

7+7+9

7 + 9 + 12

12

7 + 12

9 + 18

12

7 + 12

9 + 18

7 + 7 + 12

7 + 12 + 12

18

7 + 18

18

7 + 18

7 + 7 + 18

9+9+9

9 + 9 + 12

38 Types of Indoor Unit Combinations


One Unit

Two Units

Three Units

Four Units

7+7

9+9

12 + 12

7+7+7

7+9+9

7 + 12 + 18

9 + 12 + 12

7+7+7+7

7+7+9+9

9+9+9+9

7+ 9

9 + 12

12 + 18

7+7+9

7 + 9 + 12

9+9+9

9 + 12 + 18

7+7+7+9

7 + 7 + 9 + 12

9 + 9 + 9 + 12

12

7 + 12

9 + 18

7 + 7 + 12

7 + 9 + 18

9 + 9 + 12

12 + 12 + 12

7 + 7 + 7 + 12

7+9+9+9

18

7 + 18

7 + 7 + 18

7 + 12 + 12

9 + 9 + 18

7 + 7 + 7 + 18

7 + 9 + 9 + 12

56

AC Inverter Multi

220-240V~,50Hz

AC Inverter Multi Eco

220-240V~,50Hz

Cooling & Heating

R407C

Indoor unit
M2OA-18HRIN2

Model

Capacity
Cooling/Heating
Performance
Dimension (WxHxD)
Packing (WxHxD)
Net/Gross Weight

Air flow volume


Indoor noise level
Liquid side/Gas side

Body
Panel
Body
Panel
Body
Panel

IMSHI-07HRIN1

IMSHI-09HRIN1

IMSHI-12HRIN1

IMST2I-07HRIN1

IMST2I-09HRIN1

Btu/h

7000/9000

9000/11000

12000/13500

7000/9000

9000/11000

mm
mm
mm
mm
kg
kg
3
m /h
dB(A)
mm

750x250x205

815x280x215

955x210x385

830x336x285

915x360x290

1114x277x469

8/10

10/12

15/19

600
33
6.35/ 12.7

480
34
6.35/ 9.53

Model

Capacity
Cooling/Heating
Performance
Dimension (WxHxD)
Packing (WxHxD)
Net/Gross Weight

Air flow volume


Indoor noise level
Liquid side/Gas side

Body
Panel
Body
Panel
Body
Panel

500
30
6.35/ 9.53

520
32

550

R407C

IMST2I-12HRIN1

IMST2I-18HRIN1

IMSQ4I-07HRIN1

IMSQ4I-09HRIN1

IMSQ4I-12HRIN1

IMSQ4I-18HRIN1

Btu/h

12000/15000

18000/20500

7000/9000

9000/11000

12000/15000

18000/20500

mm
mm
mm
mm
kg
kg
m3/h
dB(A)
mm

955x210x385

1301x210x385

1114x277x469

1459x277x469

15/19

18/22

580
35
6.35/ 12.7

660
40

580x254x580
650x30x650
750x340x750
715x115x715
21/30
3/5
500
32
6.35/ 9.53

600
33

680
35
6.35/ 12.7

860
40

One outdoor unit can drive 3 free-matched indoor units at most.

Outdoor unit
Model

Power
Voltage,Frequency,Phase
Capacity
Cooling
Heating
Electrical Data
Power Input

V~,Hz,Ph
min.-nom.-max Btu/h
min.-nom.-max
kW
min.-nom.-max Btu/h
min.-nom.-max
kW

IM2OA-18HRIN1

IM3OA-27HRIN1

IM4OA-27HRIN1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

5459-18084-22519
1.6-5.3-6.6
7848-23543-25249
2.3-6.9-7.4

9383-26614-31732
2.75-7.8-9.3
10714-30708-36850
3.14-9.0-10.8

9622-27296-32755
2.82-8.0-9.6
11055-31732-38214
3.24-9.3-11.2

0.45-1.6-2.36
0.79-2.42-3.4
Cooling min.-nom.-max
kW
Heating min.-nom.-max
0.6-1.89-2.55
0.83-2.57-3.72
kW
Operating Current Cooling min.-nom.-max
2.13-7.58-11.17
3.74-11.46-16.10
A
Heating min.-nom.-max
A
2.62-8.25-11.13
3.62-11.21-16.23
Performance
EER-Energy Class
W/W
3.22-A
3.31-A
COP-Energy Class
W/W
3.65-A
3.50-B
Dimension (WxHxD)
845x695x335
845x695x335
mm
Packing (WxHxD)
975x772x405
975x772x405
mm
Net/Gross Weight
71/74
72/76
kg
3
Outdoor air flow
2200
2400
m /h
Outdoor noise level
dB(A)
53
55
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.

57

M3OA-27HRIN2

0.83-2.58-3.6
0.88-2.72-4.0
3.93-12.22-17.05
4.17-12.88-18.94
3.10-B
3.42-B
895x860x330
1043x915x395
80/84
3500
57

13 Types of Indoor Unit Combinations


One Unit

1-Compressor Dual Split Type


One inverter compressor drives two
indoor units.

Two Units

7+7

9+9

12 + 12

7+9

9 + 12

12 + 18

12

7 + 12

9 + 18

18

7 + 18

A1
COMP
A
A2
Outdoor Unit

22 Types of Indoor Unit Combinations


One Unit

Two Units

Indoor Units

1-Compressor Triple Split Type


One inverter compressor drives three
indoor units.

Three Units

7+7

9+9

12 + 12

7+7+7

7+9+9

7+9

9 + 12

12 + 18

7+7+9

7 + 9 + 12

12

7 + 12

9 + 18

7 + 7 + 12

7 + 12 + 12

18

7 + 18

7 + 7 + 18

9+9+9

9 + 9 + 12

A1
COMP
A

A2

Outdoor Unit

Indoor Units

A3

58

AC Inverter Multi Eco

220-240V~,50Hz

Cooling & Heating

Multi Series

220-240V~,50Hz

R410A

M2OA-18HRN1
M2OA-21HRN1

Indoor unit

2-Compressor Dual Split Type


Two constant-speed compressors independently
drive two indoor units.

Model

Capacity
Cooling/Heating
Performance
Dimension (WxHxD)
Packing (WxHxD)
Net/Gross Weight

Air flow volume


Indoor noise level
Liquid side/Gas side

Body
Panel
Body
Panel
Body
Panel

IMSGI-07HRIN2

IMSGI-09HRIN2

IMSGI-12HRIN2

IMST2I-07HRIN2

IMST2I-09HRIN2

Btu/h

7000/9000

9000/11000

12000/13500

7000/9000

9000/11000

mm
mm
mm
mm
kg
kg
3
m /h
dB(A)
mm

750x250x188

815x280x195

955x210x385

830x336x280

915x360x275

1114x277x469

8.5/10.5

10.5/13.5

15/19

500
30
6.35/ 9.53

560
31
6.35/ 12.7

480
34
6.35/ 9.53

COMP
A

COMP
B

Outdoor Unit

Indoor Units

R410A
550

M3OA-27HRN1
M3OA-30HRN1
2-Compressor Triple Split Type
One constant-speed compressor drives one indoor
unit,while another constant-speed compressor
drives two indoor units.
B

Model

Capacity
Cooling/Heating
Performance
Dimension (WxHxD)
Packing (WxHxD)
Net/Gross Weight

Air flow volume


Indoor noise level
Liquid side/Gas side

IMST2I-12HRIN2

IMST2I-18HRIN2

IMSQ4I-07HRIN2

IMSQ4I-09HRIN2

IMSQ4I-12HRIN2

IMSQ4I-18HRIN2
A1

Body
Panel
Body
Panel
Body
Panel

Btu/h

12000/15000

18000/20500

7000/9000

mm
mm
mm
mm
kg
kg
m3/h
dB(A)
mm

955x210x385

1301x210x385

1114x277x469

1459x277x469

15/19

18/22

580
35
6.35/ 12.7

660
40

580x254x580
650x30x650
750x340x750
715x115x715
21/30
3/5
500
32
6.35/ 9.53

9000/11000

12000/15000

COMP
B

18000/20500

COMP
A

A2

Outdoor Unit

600
33

680
35
6.35/ 12.7

860
40

Indoor Units

One outdoor unit can drive 3 free-matched indoor units at most.


Cooling & Heating

Indoor unit

Outdoor unit
Model

Power
Voltage,Frequency,Phase
Capacity
Cooling
Heating
Electrical Data
Power Input
Operating Current

Cooling
Heating
Cooling
Heating

V~,Hz,Ph
min.-nom.-max
min.-nom.-max
min.-nom.-max
min.-nom.-max

Btu/h
kW
Btu/h
kW

min.-nom.-max
min.-nom.-max
min.-nom.-max
min.-nom.-max

kW
kW
A
A

IM2OA-18HRIN2

IM3OA-27HRIN2

220-240, 50, 1

220-240, 50, 1

5459-18084-22519
1.6-5.3-6.6
7848-23543-25249
2.3-6.9-7.4

9383-26613.6-31731.6
2.75-7.8-9.3
10713.68-30708-36849.6
3.14-9.0-10.8

0.47-1.68-2.40
0.64-1.97-2.64
2.23-7.95-11.36
2.79-8.60-11.52

0.83-2.56-3.51
0.90-2.66-3.87
3.93-12.12-16.62
3.93-11.61-16.89

Performance
EER-Energy Class
W/W
3.15-B
COP-Energy Class
W/W
3.50-B
Dimension (WxHxD)
845x695x335
mm
Packing (WxHxD)
975x772x405
mm
Net/Gross Weight
71/74
kg
3
Outdoor air flow
2200
m /h
Outdoor noise level
dB(A)
53
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.

59

3.05-B
3.38-C
845x695x335
975x772x405
72/76
2400
55

Model
Capacity
Cooling/Heating
Air Flow
High/Medium/Low
Dimension (WxHxD)
Packing (WxHxD)
Net/Gross Weight
Indoor noise level (Hi/Mi/Lo)
Liquid side/Gas side

Btu/h
m3/h
mm
mm
kg
dB(A)
mm

IMSHI-09HRN1

IMSHI-12HRN1

IMST2I-09HRN1

IMST2I-12HRN1

IMSQ4I-09HRN1

IMSQ4I-12HRN1

9000/10000
500
750x250x205
830x336x285
8/10
32
6.35/ 9.53

12000/13000
520
815x280x215
915x360x290
10/12
33
6.35/ 12.7

9000/11000
550
955x210x385
1114x277x469
15/19
34
6.35/ 9.53

12000/15000
580

9000/11000
600
580x254x580
750x340x750
21/30
36
6.35/ 9.53

12000/15000
680

35
6.35/ 12.7

35
6.35/ 12.7

Outdoor unit

Capacity
Cooling/Heating

Model
Btu/h
kW

IM2OA-18HRN1

IM2OA-21HRN1

IM3OA-27HRN1

IM3OA-30HRN1

9000x2/10000x2
2.6x2/2.9x2

9000+12000/10000+14000
2.6+3.5/2.9+4.1

9000x3/10000x3
2.6x3/2.9x3

9000x2+12000/10000x2+14000
2.6x2+3.5/2.9x2+4.1

1600+950/1600+950
8.0+5.2/7.7+5.1

1800+1100/1800+1050
8.8+5.7/8.6+5.6

3.06
3.48
860x830x330
983x915x425
90/94
2900
58

3.01
3.47

Electrical Data
220-240, 50, 1
V~,Hz,Ph
Voltage,Frequency,Phase
840x2/840x2
840+1150/840+1150
W
Power Input
Cooling/Heating
4.0x2/4.0x2
4.0+5.7/4.0+5.7
A
Operating Current Cooling/Heating
Performance
EER
W/W
3.10
3.07
COP
W/W
3.45
3.52
Dimension (WxHxD)
mm
895x655x345
Packing (WxHxD)
mm
1050x720x470
Net/Gross Weight
kg
73/77
79/83
Outdoor air flow
m3/h
2000
Outdoor noise level
dB(A)
55
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.

60

Multi Eco

220-240V~,50Hz

R407C

Multi Star

220-240V~,50Hz

R22

M2OA-18HRN2

M2OA-18HR

M2OA-21HRN2

M2OA-21HR

2-Compressor Dual Split Type

2-Compressor Dual Split Type

Two constant-speed compressors independently

Two constant-speed compressors independently

drive two indoor units.

drive two indoor units.


A

COMP
A

COMP
B

COMP
A

Outdoor Unit

Indoor Units

COMP
B

Outdoor Unit

Indoor Units

R22

R407C
M3OA-27HRN2

M3OA-27HR

M3OA-30HRN2

M3OA-30HR

2-Compressor Triple Split Type

2-Compressor Triple Split Type

One constant-speed compressor drives one indoor


unit,while another constant-speed compressor

One constant-speed compressor drives one indoor


unit,while another constant-speed compressor

drives two indoor units.

drives two indoor units.

COMP
B

COMP
A

A1

A1
COMP
B

A2

Outdoor Unit

Indoor Units

COMP
A

A2

Outdoor Unit

Indoor Units

One outdoor unit can drive 3 free-matched indoor units at most.


Cooling & Heating

Cooling & Heating

Indoor unit
Indoor unit
Model

Model
Capacity
Cooling/Heating
Air Flow
High/Medium/Low
Dimension (WxHxD)
Packing (WxHxD)
Net/Gross Weight
Indoor noise level (Hi/Mi/Lo)
Liquid side/Gas side

Btu/h
m3/h
mm
mm
kg
dB(A)
mm

IMSGI-09HRN1

IMSGI-12HRN1

IMST2I-09HRN2

IMST2I-12HRN2

IMSQ4I-09HRN2

IMSQ4I-12HRN2

9000/10000
520
750x250x188
830x336x280
8.5/10.5
30
6.35/ 9.53

12000/13000
560
815x280x195
915x360x275
10.5/13.5
31
6.35/ 12.7

9000/11000
550
955x210x385
1114x277x469
15/19
34
6.35/ 9.53

12000/15000
580

9000/11000
600
580x254x580
750x340x750
21/30
36
6.35/ 9.53

12000/15000
680

35
6.35/ 12.7

Capacity
Cooling/Heating
Performance
Dimension (WxHxD)
Packing (WxHxD)

35
6.35/ 12.7

Net/Gross Weight
Air flow volume
Indoor noise level
Liquid side/Gas side

Body
Panel
Body
Panel
Body
Panel

IMSGI-09HR
MSGI-09HR

IMSGI-12HR

IMST2I-09HR

Btu/h

9000/10000

12000/13000

mm
mm
mm
mm
kg
kg
m3/h
dB(A)
mm

750x250x188

815x280x195

955x210x385

830x336x280

915x360x275

1114x277x469

8.5/10.5

10.5/13.5

15/19

520
30
6.35/ 9.53

560
31
6.35/ 12.7

550
34
6.35/ 9.53

9000/11000

IMST2I-12HR
12000/15000

580
35
6.35/ 12.7

IMSQ4I-09HR

9000/11000

IMSQ4I-12HR

12000/15000

580x254x580
650x30x650
750x340x750
715x115x715
21/30
3/5
600

680

6.35/ 9.53

6.35/ 12.7

Outdoor unit

Capacity
Cooling/Heating

Model
Btu/h
kW

IM2OA-18HRN2

IM2OA-21HRN2

IM3OA-27HRN2

IM3OA-30HRN2

9000x2/10000x2
2.6x2/2.9x2

9000+12000/10000+13000
2.6+3.5/2.9+3.8

9000x3/10000x3
2.6x3/2.9x3

9000x2+12000/10000x2+13000
2.6x2+3.5/2.9x2+3.8

1750+1000/1700+1000
8.6+5.4/8.4+5.4

1850+1200/1800+1150
9.0+6.2/8.9+5.9

2.84
3.22
860x830x330
983x915x425
90/94
2900
58

2.85
3.25

Electrical Data
220-240, 50, 1
V~,Hz,Ph
Voltage,Frequency,Phase
920x2/900x2
920+1220/900+1150
W
Power Input
Cooling/Heating
4.5x2/4.5x2
5.0+6.0/5.0+6.0
A
Operating Current Cooling/Heating
Performance
EER
W/W
2.83
2.85
COP
W/W
3.22
3.27
Dimension (WxHxD)
mm
895x655x345
Packing (WxHxD)
mm
1050x720x470
Net/Gross Weight
kg
73/77
79/83
Outdoor air flow
m3/h
2000
Outdoor noise level
dB(A)
55
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.

61

Outdoor unit

Capacity
Cooling/Heating

Model
Btu/h
kW

IM2OA-18HR

IM2OA-21HR

IM3OA-27HR

IM3OA-30HR

9000x2/10000x2
2.6x2/2.9x2

9000+12000/10000+13000
2.6+3.5/2.9+3.8

9000x3/10000x3
2.6x3/2.9x3

9000x2+12000/10000x2+13000
2.6x2+3.5/2.9x2+3.8

1750+1000/1700+1000
8.6+5.4/8.4+5.4

1850+1200/1800+1150
9.0+6.2/8.9+5.9

9.82, 2.84
3.22
860x830x330
983x915x425
90/94
2900
58

9.84, 2.85
3.25

Electrical Data
220-240, 50, 1
Voltage,Frequency,Phase
V~,Hz,Ph
920x2/900x2
920+1220/900+1150
Power Input
Cooling/Heating
W
4.5x2/4.5x2
5.0+6.0/5.0+6.0
Operating Current Cooling/Heating
A
Performance
9.78, 2.83
9.81, 2.85
Btu/W.h, W/W
EER
3.22
3.27
W/W
COP
895x655x345
mm
Dimension (WxHxD)
1050x720x470
mm
Packing (WxHxD)
79/83
73/77
kg
Net/Gross Weight
2000
m3/h
Outdoor air flow
55
Outdoor noise level
dB(A)
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in anechoic chamber.

62

Heating Water System


R407C

Overview of heating water system

[ R ] Series

R22

Based on reverse Carnot cycle principle, heating water system is one of the most advanced water heater
with the highest COP. Heating water system generally consists of compressor, evaporator, expansion valve,
strainer, accumulator tank, condenser, water tank.

Integrative

7kW

9.0kW

17.5kW

35kW

The sketch of system connection

Heating Water System


Compressor

Integrative

Integrated design of main unit and


tank makes it very conveniently using
only by connecting the water inlet
and outlet pipes.

Air inlet

High temperature

Hot water

Heat exchanger
for water

Heat exchanger
for air

Water tank

Low temp.

Hot water

Expansion Valve
Cool water

64

Heating Water System

Environmental Protection
Heating water system is environmentally friendly and low energy consuming.

Installation sketch for single unit

Economical
Water tank

Less additional operation charge; No need for transportation and storage of


fuel; simple maintenance and reparation.

Drain valve

Heat pump
water heater

COP up to 4.0.

To user

Pressure meter
Filter
Pipe union

Water pump

Cutoff valve

Water supply

Safety
Heating water system does not need storage of fuel and fuel pipe, therefore,
it is free of fuel leakage, fire and explosion.

Installation sketch for multi units

The unit has multi-protection functions: high-pressure protection, low-pressure


protection, overflow and overload protection for compressor, startup delay,

valve

valve

valve

Heat pump
water heater

valve

Heat pump
water heater

valve

ON/OFF

Heat pump
water heater

Convenience

Heat pump
water heater

of water tank.

Heat pump
water heater

Heat pump
water heater

water switch, water temperature overhigh protection and water level protection

valve

Automatic intelligent controlling system defrosts automatically in cold winter.


Outdoor installation; no special equipment room needed.

Durability
Famous brand compressor and plate heat exchanger equipped.

valve

valve

valve

valve

valve

valve

Pipe choice

Quintuple antirust technique ensures excellent durability.

Number of unit (set)

1~3

4~6

7~9

10~12

Pipe diameter (inch)

1~111
4

1
1
1-~14
2

1
1-~2
2

2~3

13~16

Widely applicable
Within the temperature range from -10 to 400C, the heating water system can
work all year around, and perform well against bad weather.

65

3~4

66

Heating Water System


Specification

Model

MGH-F35W/S

MGH-F17.5W/S

MGH-F9W

MGH-F7W

Heating capacity

kW

35

17.5

9.0

7.0

Rated power

kW

9.0

4.5

2.3

2.0

16.6

8.6

11.0

10.0

Hot water volume

m3/h

1.0

0.5

0.26

0.16

Max power

kW

11.8

5.8

3.1

2.3

Max current

20.2

9.8

14.8

14.0

Rated current

Specification, power supply

220V 1N ~ 50HZ

380V 3N ~ 50HZ

Manual,Auto and failure alarm

Controlling method
Compressor (power x quantity)

4.25kW x 2

4.25kW x 1

Refrigerant
Refrigerant charge

2300g x 2

2200g x 1

Outlet water temp


Specification of
water system

Diameter,water inlet pipe

Max compression resistance

Motor power
Type of air outlet
Length

Demension

67

1300g x 1

1000g x 1
tube-tube heat exchanger

stainless steel plate heat exchanger


DN20

DN25

DN15

DN15

DN25

DN20

DN15

DN15

1.0Mpa

1.0Mpa

1.0Mpa

0.8Mpa

innergroove copper pipe,hydrophilic aluminum coil

Type
(gas side)

1.9kW x 1

60 (default)

Heat exchanger(water side)

Diameter,water outlet pipe

Heat exchanger

2.2kW x 1

R22/R407C

250W x 2

150W x 2

125W

100W

Vertical air discharge

Side air discharge

Vertical air discharge

Side air discharge

1290mm

940mm

555mm

900mm

Width

750mm

340mm

555mm

530mm

Height

1540mm

1245mm

840mm

1200mm

Weight

kg

290

135

77

70

Noise level

dB(A)

58

54

52

50

Accessories

Heat Recovery Ventilator (HRV)


Specification

Features
Adopt centrifugal fan with lower power
consumption and longer air supply distance;
Easy control, operation friendly;
Compact design, easy installation &
maintenance;
Optional sprayer to increase unit heatexchanging efficiency;
Can be controlled together with other freshair units.

Model

XFHQ-4DZ-A

XFHQ-5DZ-A

XFHQ-6DZ-A

XFHQ-8DZ-A

XFHQ-10DZ-A

(m3 /h)

400

500

600

800

1000

Air Volume
Static Pressure (Pa)
Cooling
Heating

55

150

150

150

170

temp. efficiency(%)

68

66

66

65

70

enthalpy efficiecy(%)

52

50

50

52

54

temp. efficiency(%)

69

66

66

65

70

enthalpy efficiecy(%)

61

58

56

62

type
Motor

Energy saving
Fresh-air and exhaust air are crossed through
the heat exchanger.
Temperature exchange were happened in the
heat recovery ventilator.
Fresh-air can be got a great deal of energy
from exhaust air.

58
220V~50Hz

Power supply

heat
exchanger
exhaust air

Dimension
supply fan

outdoor air intake

fresh supply air

power (W)

30x2

90x2

90x2

150x2

200x2

current (A)

0.35x2

0.6x2

0.6x2

1x2

1x2

length (mm)

820

1350

1350

1350

1350

width (mm)

1020

820

820

820

1020

height (mm)

270

360

360

420

420

centrifugal, direct transmission,three speed abailable

Fan Motor type

indoor return air

exhaust fan

Single Phase Asynchronous Motor

Strainer

Nylon Strainer

Structure

High Quality Steel Board,Static Electricity coating,Heat preservation Material

Weight (kg)

50

76

76

82

102

Noise Level dB (A)

45

52

52

54

56

High efficiency
Adopt high quality heat-exchange core.
Small air resistance;

Model

XFHQ-15DZ/S-A

XFHQ-20DZ/S-A

XFHQ-25DZ/S-A

XFHQ-30DZ/S-A

Air Volume (m3 /h)

1500

2000

2500

3000

Static Pressure (Pa)


Cooling
Heating

Low noise

170

190

150

240

temp. efficiency(%)

68

70

68

66

enthalpy efficiecy(%)

52

55

51

50

temp. efficiency(%)

68

70

68

66

enthalpy efficiecy(%)

58

61

57

58

Power supply

3N 380V~50Hz
type

Add sound absorption material,quiet operation.


Motor

Three-phase Asynchronous Motor

power (W)

370x2

current (A)

1.1x2

Fan Motor type

Flexible multi control ways


Can be controlled together with other indoor
units by controller.

69

Dimension

450x2

550x2

800x2

1.2x2

1.4x2

2.5x2

Centrifugal,Outside Rotor,Forward-curved,Single Speed


length (mm)

1510

1510

1610

1620

width (mm)

1020

1330

1330

1330

height (mm)

480

480

520

860

Strainer
Structure

Nylon Strainer
High Quality Steel Board,Static Electricity coating,Heat preservation Material

Weight (kg)

156

178

195

210

Noise Level dB (A)

56

57

58

60

70

Auxiliary Electric Heater


SDH series

SDS series

Features

Features
high efficiency heater tube, uniform heating;

Adopts stainless steel, filling with the high-quality heatresistance material between outer shell and interior also

10bar hydraulic test, high safety;

have strong anticorrosive capability.

easy for service and maintenance;

Adopts the famous-brand temperature controller to prevent

customize for special requirements.

electric device from damaging.


Uniform heating and high efficiency.

D
E

water inlet
electric heater

inner layer insulation layer

wire hole

fix hole
drain valve

total length
Dimension of cylinder water inlet & outlet
(mm)

Model

Voltage

Power

SDS-15/S-A

380V

SDS-18/S-A

Dimension(mm)
A

15KW

960

350

280

159

130

380V

18KW

960

350

280

159

130

SDS-27/S-A

380V

27KW

1260

350

280

203

180

SDS-30/S-A

380V

30KW

1260

350

280

203

180

SDS-45/S-A

380V

45KW

1160

400

335

219

180

Voltage
(V)

Power
(kw)

SDH-2-A

220/380

2kW

350

SDS-54/S-A

380V

54KW

1360

450

390

245

220

SDH-3-A

220/380

3kW

350

SDS-60/S-A

380V

60KW

1360

450

390

245

220

400

SDS-72/S-A

380V

72KW

1200

480

390

273

240

SDS-75/S-A

380V

75KW

1200

480

390

273

240

SDS-90/S-A

380V

90KW

1360

530

440

325

240

Model

SDH-4-A
SDH-5-A
SDH-6-A

220/380
220/380

4kW
5kW

400

*158mm

1.25''

220/380

6kW

450

SDS-100/S-A

380V

100KW

1520

530

440

325

240

SDH-7/S-A

380

7kW

450

SDS-120/S-A

380V

120KW

1660

600

492

426

240

SDH-8/S-A

380

8kW

410

SDS-144/S-A

380V

144KW

1960

600

540

426

240

SDH-9/S-A

380

9kW

410

SDS-150/S-A

380V

150KW

1960

600

540

426

240

510

SDS-175/S-A

380V

175KW

1660

650

598

480

280

SDS-180/S-A

380V

180KW

1660

650

598

480

280

SDS-200/S-A

380V

200KW

1960

650

598

480

280

SDH-10/S-A
SDH-12/S-A

71

water outlet
temp. protector

case

cover

water-proof cover

380
380

10kW
12kW

510

SDH-15/S-A

380

15kW

560

SDH-20/S-A

380

20kW

560

*190mm

1.5''

72

Controller

Description

Picture

Model

Function

Central Controller
Remote Controller
(Standard)

R51, R05/BG

suitable for MDV system


SET BUTTON

MODE BUTTON

Enter into the setting screen.

Choose the mode.

QUERY BUTTON

FAN SPEED BUTTON

Check the running status


of the A/C.

Adjust fan speed.


PREVIOUS OR NEXT BUTTON

TIMER BUTTON

Wire Controller
(Optional)

In query or set mode, Transfer


between previous and next unit.

Set the current time and off


time.

KJR-01B/dP(T)

suitable for MDV system

SWING BUTTON

DATAS OR PAGES ADJUST BUTTON

With or without swing.

Adjust the datas or pages.

OK BUTTON
Confirm the operation.

RESET BUTTON
Reset current unit to the
default setting.

OPERATION INDICATOR
Lights when the unit is in
operation.

Wire Controller
(Optional)

LOCK BUTTON
Lock or unlock current A/C
status.

ON/OFF BUTTON
Start or stop operation.

KJR-10B/dP(T)

suitable for MDV system

Wire Controller
Central Control Monitor
(Optional)

CCM01

Control 64 indoor units


simultaneously at most
(suitable for MDV system)
AUXILIARY HEATER BUTTON
Start or stop the electrical
auxiliary heater
FOLLOW ME BUTTON

Central Control Monitor


(Optional)

CCM10

Control 32 outdoor units


simultaneously at most
(suitable for MDV system)

Adjust the action of indoor unit


according to the Temp. sensor inside
the wire controller

TIMER BUTTON
Timer setting.
OK BUTTON
Confirm the operation
RESET BUTTON
Reset all the setting and
get in to the condition of
beginning.

Touch Controller
(Optional)

73

TCM01

Suitable for Intelligent built-in


manager system

MODE BUTTON
Choose the mode.

ON/OFF BUTTON
Start or stop operation.

ECONOMY BUTTON
Start or stop economical
mode
TEMP. BUTTON
Preset temperature.

SWING BUTTON
With or without swing.
FAN SPEED BUTTON
Choose fan speed.
LOCK BUTTON
Lock or unlock all current
setting.

74

Distributor
Refrigerant Distributor Dimension Chart
The connecting point can be freely adjusted to meet different pipes.
Adoption of international standard measurement assures easy replacement.

BY51N1

BY104

BY105

BY101N1

The dimension of Y-shape three-way pipe.


BY102A

75

BY103A

MDV-DY01

MDV-DY02

76

You might also like