Question: 1
How many DIMMs are required for he minimum memory configuration on a server with four-way
A. 1
B. 2
C. 4
D. 8
Answer: C
Question: 2
Answer: A
Question: 3
What is the PCI slot color coding scheme for Dell powerEdge servers?
Answer: C
Question: 4
Which two Dell servers are rack dense optimized? (Choose two.)
A. powerEdge 1750
B. powerEdge 2600
C. powerEdge 1655MC
D. PowerEdge 1600Sc
Answer: A, C
Question: 5
Answer: D
Question: 6
What does 2 + 1 mean in the system specifications for the power subsystem?
A. The server has two AC inputs that are switched to a single supply to redundant AC sources.
B. The server has two power supplies with one AC input fed to both, providing redundant power
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
supplies.
C. The server must have two power supplies in order to operate and a third power supply is the
redundant supply.
D. The server must have one power supply in order to operate and the two additional power
Answer: C
Question: 7
Answer: D
Question: 8
C. Provides redundancy by maintaining parity info on the DRAM to detect and correct single bit
errors
D. Provides speed improvements by allowing addressing to be set for the next access to the
same DIMM, while data are being read from the previous access
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Answer: C
Question: 9
D. processor mounting parallel to the system board in 2U, quad processor systems
Answer: A, B
Question: 10
Which visual clue alerts you that a virtual disk requires a signature to be written to it?
Answer: D
Question: 11
Which key sequence is used to assess the Adaptec PERC BIOS Configuration Utility during boot
up?
A. CRTL +A
B. CTRL +M
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
C. CTRL +C
Answer: A
Question: 12
You are adding an additional drive and wanting to go from RAID 1 to RAID 5. Using Array
A. You right-click PERC 2 and select Reconfigure from the options list.
C. You right-click on data, choose Reconfigure, than choose RAID 5 as RAID type.
D. You choose Reconstruct from the pull-down menu at the top right side of the task bar. Auto
Answer: C
Question: 13
What is the maximum number of primary partitions allowed by Array Manager for three disk
arrays?
A. 6
B. 9
C. 12
D. 15
Answer: C
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Question: 14
Answer: A
Question: 15
The drive that contains the user home folders is running out of space. This partition is labeled D
and is a part of a three disk RAID 5 labeled Virtual DISK 2. You want to increase the size of the
partition by adding an additional hard drive to the virtual disk. How can you do this when a PERC
3/Di is used?
A. Array Manager is used to expand the virtual disk onto an additional hard drive.
B. You back up the virtual disk. Array Manager is used to expand the virtual disk onto an
C. You use Array Manager to delete Virtual Disk 2 and re-create it including the additional hard
disk. You restore the contents of the original virtual disk from the RAID 5 parity.
D. You back up Virtual Disk 2. Array Manager is used to delete virtual Disk 2 and recreate it
including the additional hard disk. You re-create the D partition and restore its contents from
tape.
Answer: D
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Question: 16
Using Array Manager, what must you do when changing the drive letter of one of your volumes?
(Choose two.)
A. You must ensure the volume does not contain the boot volume.
B. First you must ensure the drive letter has removed by selecting the Remove option. The drive
C. You must find if three are program(s) installed on that volume, because changing the drive
D. You must ensure you are using Microsoft windows 2000 operating drive letters cannot be
Answer: A, C
Question: 17
Which utility allows you to create, delete, and manage containers in the Adaptec PERC BIOS
Utility?
A. Disk utilities
B. SCSI utilities
Answer: D
Question: 18
Which three tasks can be accomplished using the System Setup Utility of a Dell PowerEdge
Answer: A, B
Question: 19
What should you do to clear NVRAM and force system to reset its configuration data?
C. in the System Setup utility, activate the NUM Lock, and Scroll Lock lights on the keyboard,
Answer: C
Question: 20
Which two are needed to update the ESM on a PowerEdge server? (Choose two.)
Answer: A, C
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Question: 21
Which two statements about the OMSA Update Service's function are true? (Choose to.)
C. It lets you view a current version report for BIOS, firmware, and OS.
D. It lets you track BIOS and firmware updates through their record in the Command Log.
Answer: C, D
Question: 22
Which three hard drive partitions must be defined during the automated Linux installation
A. root
B. logs
C. boot
D. data
E. swap
Answer: A, B, C
Question: 23
Where in the Dell Server Assistant (DSA) interface can you erase all hard in preparation for a
A. Drive Utility
B. Server Setup
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
C. Setup Wizard
D. System Tools
Answer: D
Question: 24
Which two operations can be performed with the DSA CD? (Choose two.)
D. change the Dell Service Tag via the Service Tag Utility
Answer: B, C
Question: 25
You want to install Windows 2000 Server and Dell-validated for your factory-installed devices
using the Dell Server Assistant CD. From which location should you launch the Dell Server
Assistant?
B. autorun the CD from the Windows desktop after installing Windows 2000
C. boot to the Dell Server Assistant CD and have your Windows CD available
D. use the Dell Server Assistant to create a Utility partition and launch the installation from the
utility partition
Answer: C
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Question: 26
Answer: D
Question: 27
Answer: B
Question: 28
A. NDS
B. PAM
C. NTLM
D. SNMP
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Answer: C
Question: 29
You can use OMSA to remotely update the firmware for which two components? (Choose two.)
A. BIOS
B. System software
Answer: A, D
Question: 30
Answer: D
Question: 31
Which two steps are of configuring SNMP for OpenManage products on the managed node?
(Choose two.)
C. configure the contact and location in the Agent tab of the SNMP service
Answer: A, D
Question: 32
The system administrator notices the Dell badge on the front of the server is flashing orange on
the PowerEdge 2650. What utility should the system administrator load to determine the cause of
Answer: D
Question: 33
Which OpenManage component is the central repository for asset and inventory information?
A. IT As sistant
B. Server Agent
C. Array Manager
Answer: A
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Question: 34
If there is a loss of power redundancy on your PowerEdge server, in which three ways can Dell
B. The status panel for that system indicates which power supply failed.
Answer: A, B, C
Question: 35
If the server is operating normally, the Remote Access Controller allows an administrator to do
Answer: B, D
Question: 36
OpenManage Administrator can determine the status of which two server components?
(Choose two.)
A. f
B. Answer
C. memory
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
D. disk utilization
E. processor load
F. network activity
Answer: A, B
Question: 37
At a remote site, a server is no longer able to communicate on the network. Which tool would an
A. SMB
B. Server Assistant
C. Server Diagnostics
Answer: D
Question: 38
Which two statements are true about executing Server Diagnostics using OMSA? (Choose two.)
B. You must have Admin or Power User privileges to execute the diagnostic tests.
D. You can click Result History to see a record of the results of diagnostic tests that have already
been executed.
Answer: B, D
Question: 39
Which three requirements must you meet to install OMSA in a Red Hat Linux environment?
(Choose three.)
E. The "ucd-snmp" or "net-snmp" package that is provided with the operating system must be
installed.
Answer: A, B, C
Question: 40
You are monitoring 100 servers in your environment using ITA. You want to determine which
Servers are equipped with a remote access controller and the Array Manger agent, as well as
view the physical memory of each server on one screen. How should you view this information
from ITA?
A. go to the ITA Logs tab, select the information you want to view, and click the Refresh button
B. go to the ITA Remote Address Book, select the information you want to view, and click the Get
Addresses button
C. go to the ITA Inventory view, select the information you want to view, and click the Get
Inventory button
D. go to the ITA Search view, select all the information you want view using one query, and click
Answer: C
Question: 41
A. a page
B. an alert popup
C. a forward event
D. an e-mail message
Answer: A, B, D, E
Question: 42
You just added a new Dell PowerEdge server to the network. In order to use Dell OpenManage IT
Assistant to manage it, which three steps do you need to take? (Choose three.)
E. ensure that the new server's IP address is in the discovery specified for OpenManage IT
Assistant
Answer: A, B, C
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Question: 43
A. You make sure OpenManage IT Assistant has discovered the managed node running
Dell
C. You configure the SNMP service on the computer on which OpenManage IT Assistant is
running (the management station) to the correct read community name so that it can read
traps when it discovers the managed node on which Dell OpenManage Sever
Administrator is running.
E. You configure the SNMP service trap destinations on the computer on which Dell
Answer: D
Question: 44
You have the PowerEdge server running Red Hat Linux Advanced Sever Operating System. You
--change System Reset Timer value under the Auto Recovery tab
--set the Beep Speaker on the sever Alert Action under Alert Management tab
Which two access privileges allow you to accomplish these tasks? (Choose two.)
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
A. root user
C. administrator user
Answer: A, D
Question: 45
What is the correct NIC teaming for the Intel proprietary Method to accomplish fault tolerance?
A. AFT
B. ALB
C. ATF
D. SLB
Answer: A
Exhibit:
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Place in order the steps necessary to team adapters in a Microsoft Windows Environment.
Answer:
Question: 47
C. It lets you tr
Answer: C
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Question: 48
You are configuring terming on a PowerEdge server. The server has Windows 2000 installed and
you do not know what network adapters are in the system Without physically opening the chassis,
what are two ways to see which network adapters are installed using the operating system?
(Choose two.)
A. type ifconfig -a at a command prompt; on the description line, the manufacturer and device
B. type ipconfig /all at the command; on the description line, the manufacturer and device type
will be named
Answer: B, C
Question: 49
Which four steps are necessary for creating a team in Windows 2000 using BASP?
(Choose four.)
Answer: A, B, C, D
Question: 50
What happens when you specify a preferred primary Adapter in Windows 2000 for an AFT NIC
team?
A. You specify which adaptor will take the entire load. The other NICs will be used only when
B. You specify the desired card for all outgoing traffic for the team. The other member will still
C. You specify the desired card for all incoming traffic for the team. The other members will still
tr
E. You specify which adaptor will take the load until it is saturated, then the other members will
start accepting packets until the preferred primary is just below the saturation point.
Answer: A
Question: 51
You have just installed W2K on your server and you cannot get the server to see your local
B. verify that the cable plugged into your server is not a cross-over cable
C. verify that the subnet address is the same as the rest of the working devices on your LAN
Answer: B, C, D
Question: 52
Which benefit does Link Aggregation provide, as used by Intel in PowerEdge servers?
B. assures that if one adapter fails, the server remains available to the network
C. combines multiple adapters into one channel, greater bandwidth for network traffic
D. allows multiple adapters to share the network load, preventing one adapter from being
overloaded
Answer: C
Question: 53
Which three statements are true about installing the Intel drivers and utilities that allow teaming in
C. Loading Windows 2000 using the DSA CD-ROM loads the driver and ProSet Utility.
D. If you install the adapters after you have installed the OS, can get the drivers from the Intel
E. If you install the adapters after you have installed the OS, you can get the ProSet Utility from
Answer: A, B, C
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Question: 54
You need to install Intel NIC teaming for Windows 2000 and you not have access to the Internet.
From what two sources can you obtain the PROSet software? (Choose two.)
Answer: A, B
Question: 55
Which two components can be installed in the 0U space found in Dell rack? (Choose two.)
A. Dell UPS
B. Dell PDU
Answer: B, D
Question: 56
Which two features are found on both 24U Dell rack? (Choose two.)
D. 0U space that can be used for components other than servers and storage
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
Answer: A, D
Question: 57
How many PowerEdge 1650 servers can be installed in a Dell 42U rack that already has two
PowerEdge 2650 servers, a PowerEdge 6650 server, and a 1U keyboard and monitor drawer?
A. 31
B. 32
C. 33
D. 34
Answer: C
Question: 58
What is the intended mounting location for 0U rack mount device in a Dell rack?
Answer: D
Question: 59
You are about to begin the installation of Windows 2000 Server your PowerEdge server. As you
Inspect the System Setup utility, you notice that the Asset Tag field is blank. What are two ways
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
you can add the correct asset tag into the BIOS? (Choose two.)
A. Flashing the ESM to the latest revision automatically updates the Asset Tag field.
B. Flashing BIOS to the latest revision automatically updates the Asset Tag field.
C. You create the Asset Tag Utility Diskette from the DSA CD and use it to update the Asset Tag
field.
D. You download the Asset Tag Utility from premiersupport. Dell.com and use it to update the
E. After installing Windows 2000, you use the Asset manager application from the Dell group in
Answer: C, D
Question: 60
What is the default path and name of the logging file if the message Logging option is selected
A. A: RESULT .txt
B. C: RESULTS.txt
C. C: DELLTEST .txt
D. A. DELLTESTS .txt
Answer: A
Question: 61
You select the RAID Configuration Utility from the Utility partition menu.
A. system setup
http://sertificat.org | Сертификат 100% | Ответы на сертификационные тестирования
B. PERC BIOS
C. CERC BIOS
D. Array Manager
Answer: B