You are on page 1of 80

List RNC Oriented Intra-frequency Handover Measurement Algorithm Parameters

---------------------------------------------------------------------------
1F event absolute EcNo threshold[dB] -24
1F event absolute RSCP threshold[dBm] <NULL>
Intra-freq meas L3 filter coeff D3
Intra-freq Measure Quantity CPICH_EC/NO
1A event to periodical rpt number D16
1A event to periodical rpt period[ms] D4000
1C event to periodical rpt number D16
1C event to periodical rpt period[ms] D4000
1J event to periodical rpt number D64
1J event to periodical rpt period[ms] D1000
VP service 1A event relative THD[0.5dB] 6
CS non VP service 1A event relative THD[0.5dB] 6
PS service 1A event relative threshold[0.5dB] 6
VP service 1B event relative THD[0.5dB] 12
CS non VP service 1B event relative THD[0.5dB] 12
PS service 1B event relative threshold[0.5dB] 12
1A hysteresis[0.5dB] 0
1B hysteresis[0.5dB] 0
1C hysteresis[0.5dB] 8
1D hysteresis[0.5dB] 8
1F hysteresis[0.5dB] 8
1J hysteresis[0.5dB] 8
Weighted factor 0
1A event trigger delay time[ms] D320
1B event trigger delay time[ms] D640
1C event trigger delay time[ms] D640
1D event trigger delay time[ms] D640
1F event trigger delay time[ms] D640
1J event trigger delay time[ms] D640
Max evaluation period of SHO failure[s] 60
Threshold number of SHO failure 3
Relative threshold of SHO failure[dB] 2
Period of penalty timer for SHO failure after down rate[s] 30
Min quality THD for SHO[dB] -24
Max number of cell in active set 3
1F event blind handover trigger condition[dBm] -115
Intrafrequency measurement report interval of blind HO[ms] D250
Intrafrequency measurement report amount of blind handover D2
VP = Video
CS non VP = AMR voice
PS = R99, HSPA
VP = Video
CS non VP = AMR voice
PS = R99, HSPA
231509060.xls.ms_office Security Level:
O&M #4904647
%%LST INTERFREQHOCOV:;%%
RETCODE = 0 Execution succeeded.
List RNC Oriented Coverage based Inter-frequency Handover Measurement Algorithm Parameters
------------------------------------------------------------------------------------------
Inter-frequency measure periodical rpt period[ms]
2B hysteresis[0.5dB]
2B event trigger delay time[ms]
Inter-freq CS measure start Ec/No THD[dB]
Inter-freq CS measure stop Ec/No THD[dB]
Inter-freq CS measure start RSCP THD[dBm]
Inter-freq CS measure stop RSCP THD[dBm]
Inter-freq H measure start Ec/No THD[dB]
Inter-freq R99 PS measure start Ec/No THD[dB]
Inter-freq H measure stop Ec/No THD[dB]
Inter-freq R99 PS measure stop Ec/No THD[dB]
Inter-freq H measure start RSCP THD[dBm]
Inter-freq R99 PS measure start RSCP THD[dBm]
Inter-freq H measure stop RSCP THD[dBm]
Inter-freq R99 PS measure stop RSCP THD[dBm]
Inter-freq H target frequency trigger Ec/No THD[dB]
Inter-freq R99 PS target frequency trigger Ec/No THD[dB]
Inter-freq H target frequency trigger RSCP THD[dBm]
Inter-freq R99 PS target frequency trigger RSCP THD[dBm]
Inter-freq H Used frequency trigger Ec/No THD[dB]
Inter-freq R99 PS Used frequency trigger Ec/No THD[dB]
Inter-freq H Used frequency trigger RSCP THD[dBm]
Inter-freq R99 PS Used frequency trigger RSCP THD[dBm]
2B event retry max times
HHO hysteresis[0.5dB]
2B event retry period[500ms]
HHO period trigger delay time[ms]
Inter-frequency measure report mode
Inter-frequency measure filter coeff
2D hysteresis[0.5dB]
2F hysteresis[0.5dB]
Weight for Used frequency
2D event trigger delay time[ms]
2F event trigger delay time[ms]
Inter-freq CS target frequency trigger Ec/No THD[dB]
Inter-freq CS target frequency trigger RSCP THD[dBm]
Inter-freq CS Used frequency trigger Ec/No THD[dB]
Inter-freq CS Used frequency trigger RSCP THD[dBm]
Inter-freq measure timer length[s]
Inter-freq coverage handover delay trig time
5/30/2014
Confidential Information of Huawei.
No Spreading without Permission Page3of80
231509060.xls.ms_office Security Level:
D500
<NULL>
<NULL> F1 -> F3 F3 ->F1
-11 [-24, 0] -9 -9
-8 [-24, 0] -6 -6
-100 [-115, -25] -90 -90
-95 [-115, -25] -85 -85
-15 [-24, 0] -9 -13
-15 [-24, 0] -9 -13
-12 [-24, 0] -6 -11
-12 [-24, 0] -6 -11
-110 [-115, -25] -90 -105
-110 [-115, -25] -90 -105
-105 [-115, -25] -85 -100
-105 [-115, -25] -85 -100
-12 [-24, 0] -12 -12
-12 [-24, 0] -12 -12
-105 [-115, -25] -105 -105
-105 -105 -105
-15
-15
-110
-110
<NULL>
0
<NULL>
0
Periodical reporting
D3
0
0
0
D320
D1280
-8 >32 20 -14
-85 >30 40 -75
-11
-90
60
0
5/30/2014
Confidential Information of Huawei.
No Spreading without Permission Page4of80
231509060.xls.ms_office Security Level:
O&M #5737787
%%LST INTERRATHOCOV:;%%
RETCODE = 0 Execution succeeded.
List RNC Oriented Coverage based Inter-rat Handover Measurement Algorithm Parameters
------------------------------------------------------------------------------------
Inter-RAT period report interval[ms]
3A Measure Quantity
Inter-RAT hysteresis[0.5dB]
Time to trigger for non-verified GSM cell[ms]
Time to trigger for verified GSM cell[ms]
3A hysteresis[0.5dB]
3A event trigger delay time[ms]
Inter-RAT filter coeff
Inter-RAT CS measure start Ec/No THD[dB]
Inter-RAT CS measure stop Ec/No THD[dB]
Inter-RAT CS measure start RSCP THD[dBm]
Inter-RAT CS measure stop RSCP THD[dBm]
Inter-RAT CS Used frequency trigger Ec/No THD[dB]
Inter-RAT CS Used frequency trigger RSCP THD[dBm]
Inter-RAT R99 PS measure start Ec/No THD[dB]
Inter-RAT R99 PS measure stop Ec/No THD[dB]
Inter-RAT R99 PS measure start RSCP THD[dBm]
Inter-RAT R99 PS measure stop RSCP THD[dBm]
Inter-RAT R99 PS Used frequency trigger Ec/No THD[dB]
Inter-RAT R99 PS Used frequency trigger RSCP THD[dBm]
Inter-RAT H measure start Ec/No THD[dB]
Inter-RAT H measure stop Ec/No THD[dB]
Inter-RAT H measure start RSCP THD[dBm]
Inter-RAT H measure stop RSCP THD[dBm]
Inter-RAT H Used frequency trigger Ec/No THD[dB]
Inter-RAT H Used frequency trigger RSCP THD[dBm]
3A event retry max times
3A event retry period[500ms]
Inter-RAT report mode
2D2F filter coeff
Weight for Used frequency
2D hysteresis[0.5dB]
2F hysteresis[0.5dB]
2D event trigger delay time[ms]
2F event trigger delay time[ms]
BSIC verify switch
Inter-RAT CS handover decision THD[dBm]
Inter-RAT R99 PS handover decision THD[dBm]
Inter-RAT H handover decision THD[dBm]
Inter-RAT measure timer length[s]
Inter-RAT PingPong timer[s]
Inter-RAT PingPong Hyst[0.5dB]
Inter-RAT HO physical channel failure THD
5/30/2014
Confidential Information of Huawei.
No Spreading without Permission Page5of80
231509060.xls.ms_office Security Level:
Inter-Rat HO physical channel failure penalty timer[s]
fdd_qmin
5/30/2014
Confidential Information of Huawei.
No Spreading without Permission Page6of80
231509060.xls.ms_office Security Level:
RGAZH01
D500
<NULL>
0
0
0
<NULL>
<NULL>
D3
-11
-8
-100
-95
<NULL>
<NULL>
-17
-14
-115
-110
<NULL>
<NULL>
-17
-14
-115
-110
<NULL>
<NULL>
<NULL>
<NULL>
Periodical reporting
D3
0
0
0
D320
D1280
Verify mode
13 -98dBm
13 -98dBm
13 -98dBm
60
0
0
3
CS
R99
HSPA
5/30/2014
Confidential Information of Huawei.
No Spreading without Permission Page7of80
231509060.xls.ms_office Security Level:
30
-8 ??
5/30/2014
Confidential Information of Huawei.
No Spreading without Permission Page8of80
Cell Reselection Counter Threshold 9
BE D2F/R Or F/R2P 4B Threshold[byte] D64
BE D2F/R 4B Time[ms] D5000
BE D2F/R 4B Pending Time[ms] D1000
BE F2P 4B Time[ms] D5000
BE F2P 4B Pending Time[ms] D1000
BE F/R2D 4A Threshold[byte] D1024
BE F/R2D 4A Time[ms] D0
BE HS-DSCH2F 4B Threshold[byte] D64
BE HS-DSCH2F 4B Time[ms] D5000 goes to low activity state
BE HS-DSCH2F 4B Pending Time[ms] D1000
BE F2HS-DSCH 4A Threshold[byte] D1024
BE F2HS-DSCH 4A Time[ms] D0
RT D/HSPA2F 4B Threshold[byte] D64
RT D/HSPA2F 4B Time[ms] D5000
RT D/HSPA2F 4B Pending Time[ms] D16000
RT F2D/HSPA 4A Threshold[byte] D1024
RT F2D/HSPA 4A Time[ms] D240
E-DCH Throu Meas Period[10ms] 30
E-DCH2F 4B Threshold[kbit/s] 8
E-DCH2F 4B Period Amount 2
E-DCH2F 4B Pending Period Amount 4
BE F2E-DCH 4A Threshold[byte] D1024
BE F2E-DCH 4A Time[ms] D0
BE F2CPC_HS-DSCH 4A Threshold[byte] D1024
BE F2CPC_HS-DSCH 4A Time[ms] D0
RT F2CPC_HSPA 4A Threshold[byte] D1024
RT F2CPC_HSPA 4A Time[ms] D0
BE F2CPC_E-DCH 4A Threshold[byte] D1024
BE FACH2CPC_E-DCH 4A Time[ms] D0
BE E_FACH2D 4A Threshold[byte] D1024
BE E_FACH2D 4A Time[ms] D0
BE E_FACH2HS-DSCH 4A Threshold[byte] D1024
BE E_FACH2HS-DSCH 4A Time[ms] D0
RT E_FACH2D/HSPA 4A Threshold[byte] D1024
RT E_FACH2D/HSPA 4A Time[ms] D0
BE E_FACH2CPC 4A Threshold[byte] D1024
BE E_FACH2CPC 4A Time[ms] D0
RT E_FACH2CPC_HSPA 4A Threshold[byte] D1024
RT E_FACH2CPC_HSPA 4A Time[ms] D0
(Number of results 1)
---------------
Cell Reselection Timer[s] 180
BE FACH to PCH Transition Timer[s] 65535 cell PCH disable
BE DCH to FACH Transition Timer[s] 5
BE HS-DSCH to FACH Transition Timer[s] 5 from low activity state in HS-DSCH to FACH
Realtime DCH or HSPA To FACH Transition Timer[s] 180
BE E-DCH To FACH State Transition Timer[s] 5
BE CPC to FACH Transition Timer[s] 5
Realtime CPC to FACH Transition Timer[s] 180
BE DCH to E_FACH Transition Timer[s] 5
BE HSPA to E_FACH Transition Timer[s] 5
Realtime DCH or HSPA to E_FACH Transition Timer[s] 180
BE CPC to E_FACH Transition Timer[s] 5
Realtime CPC to E_FACH Transition Timer[s] 180
List PS User Inactive Detecting Timer
-------------------------------------
Conversational service T1 20
Conversational service T2 20
Streaming service T1 20
Streaming service T2 20
Interactive service T1 20
Interactive service T2 20
Background service T1 20 When detecting that the Ps' Background User had no data to transfer for a long time which longer than this timer, the PDCP layer would request the RRC layer to release this Radio Access Bear
Background service T2 20
IMS signal T1 20
IMS signal T2 20
from low activity state in HS-DSCH to FACH
When detecting that the Ps' Background User had no data to transfer for a long time which longer than this timer, the PDCP layer would request the RRC layer to release this Radio Access Bear
When detecting that the Ps' Background User had no data to transfer for a long time which longer than this timer, the PDCP layer would request the RRC layer to release this Radio Access Bear
231509060.xls.ms_office Security Level:
Parameter Min Max Typical settings
Inter-RAT measurement quantity
CPICH_Ec/No,CPI
CH_RSCP,Auto
AUTO
2D Ec/No CS threshold -24db 0db -14db
2D RSCP CS threshold -115dBm 25dBm -100db
2F Ec/No CS threshold -24db 0db -12db
2F RSCP CS threshold -115dBm 25dBm -97db
CS HO UMTS threshold For RSCP -115dBm 25dBm -97db
CS HO UMTS threshold For Ec/No -24db 0db -12db
CS HO UMTS threshold For GSM 0(-110dbm) 63(-48dbm) 16(-95dbm)
2D Ec/No R99 PS threshold -24db 0db -15db
2D RSCP R99 PS threshold -115dBm 25dBm -110db
2F Ec/No R99 PS threshold -24db 0db -13db
2F RSCP R99 PS threshold -115dBm 25dBm -107db
PS R99 UMTS HO threshold For RSCP -115dBm 25dBm -107db
PS R99 UMTS HO threshold For Ec/No -24db 0db -13db
PS R99 UMTS HO threshold For GSM 0(-110dbm) 63(-48dbm) 16(-95dbm)
2D Ec/No H threshold -24db 0db -15db
2D RSCP H threshold -115dBm 25dBm -110db
2F Ec/No H threshold -24db 0db -13db
2F RSCP H threshold -115dBm 25dBm -107db
H HO UMTS threshold For RSCP -115dBm 25dBm -107db
H HO UMTS threshold For Ec/No -24db 0db -13db
H HO UMTS threshold For GSM 0(-110dbm) 63(-48dbm) 16(-95dbm)
2D Hysteresis 0(0db) 29(14.5db) 4(2db)
2D Trigger time D0(0ms) D5000(5000ms) D320(320ms)
2F Hysteresis 0(0db) 29(14.5db) 4(2db)
2F Trigger time D0(0ms) D5000(5000ms) D1280(1280ms)
CS
PS R99
HSPA
5/30/2014 HUAWEI Confidential Page13of80
231509060.xls.ms_office Security Level:
HO Hysteresis 0(0db) 15(7.5db) 0(0db)
HO Trigger time D0(0ms) D5000(5000ms) D0(0ms)
Ssearch RAT -32 20 2(-14db)
Treselections 0 31 1(s)
Qqualmin -24 0 -18(db)
Qrxlevmin -58 -13 -58
Maxallowedultxpower -50 33 24(db)
Idleqhyst1s 0 20 2
Idleqhyst2s 0 20 2
idleqoffset1sn -50 50 0(db)
idleqoffset2sn -50 50 0(db)
fdd_qoffset 0 15 0:Always
fdd_qmin 0 7 3(-8dB)
qsearch_i 0 15 7 (Always Search)
qsearch_c 0 15 15 (never)
qsearch_p 0 15 7 (Always Search)
Cell
reseleltion
5/30/2014 HUAWEI Confidential Page14of80
231509060.xls.ms_office Security Level:
Easy / Fast Hard / Slow
-14db -15db
-95db -100db
-12db -13db
-92db -97db
-92db -97db
-12db -13db
21(-90dbm) 16(-95dbm)
-14db -15db
-105db -110db
-12db -13db
-102db -107db
-102db -107db
-12db -13db
21(-90dbm) 16(-95dbm)
-14db -15db
-105db -110db
-12db -13db
-102db -107db
-102db -107db
-12db -13db
21(-90dbm) 16(-95dbm)
2(1db) 6(3db)
D320(320ms) D640(640ms)
2(1db) 6(3db)
D640(640ms) D1280(1280ms)
5/30/2014 HUAWEI Confidential Page15of80
231509060.xls.ms_office Security Level:
0(0db) 2(1db)
D0(0ms) D10(10ms)
3(-14db) 2(-14db)
0(s) 2(s)
8(0 dB) 9(+4dB)
5(-10dB) 3(-8dB)
5/30/2014 HUAWEI Confidential Page16of80
231509060.xls.ms_office Security Level:
Value definition
The RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports
the event 2D when the measured value is smaller than the value of this parameter.
The RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports
the event 2D when the measured value is smaller than the value of this parameter.
The RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports
the event 2F when the measured value is larger than the value of this parameter.
The RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports
the event 2F when the measured value is larger than the value of this parameter.
When the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover
decision THD] is reached
When the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover
decision THD] is reached
Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to -109, ..., 63 to -48.)
the value 0 means the physical value is smaller than -110 dBm.
The RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports
the event 2D when the measured value is smaller than the value of this parameter.
The RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports
the event 2D when the measured value is smaller than the value of this parameter.
The RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports
the event 2F when the measured value is larger than the value of this parameter.
The RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports
the event 2F when the measured value is larger than the value of this parameter.
When the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover
decision THD] is reached
When the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover
decision THD] is reached
Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to -109, ..., 63 to -48.)
the value 0 means the physical value is smaller than -110 dBm.
The RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports
the event 2D when the measured value is smaller than the value of this parameter.
The RNC sends the signaling to activate compressed mode and start inter-RAT measurement, if the UE reports
the event 2D when the measured value is smaller than the value of this parameter.
The RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports
the event 2F when the measured value is larger than the value of this parameter.
The RNC sends the signaling to activate compressed mode and stop inter-RAT measurement, if the UE reports
the event 2F when the measured value is larger than the value of this parameter.
When the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover
decision THD] is reached
When the quality of the currently used UTRAN frequency is below this threshold and the [Inter-RAT handover
decision THD] is reached
Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to -109, ..., 63 to -48.)
the value 0 means the physical value is smaller than -110 dBm.
The larger the value of this parameter, the less the ping-pong effect and the fewer the decision mistakes
alue range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000( ms)
The larger the value of this parameter, the less the ping-pong effect and the fewer the decision mistakes
alue range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000( ms)
5/30/2014 HUAWEI Confidential Page17of80
231509060.xls.ms_office Security Level:
This parameter decides whether to trigger inter-RAT handovers.
alue range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560, D5000
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000( ms)
A threshold for inter-RAT cell reselection. When the quality (CPICH Ec/No measured by UE) of the serving cell is
lower than this threshold plus the [Qqualmin] of the cell, the inter-RAT cell reselection procedure will be started
Trigger time for inter RAT cell reseletion
The minimum required quality threshold corresponding to CPICH Ec/No. The UE can camp on the cell only when
the measured CPICH Ec/No is greater than the value of this parameter. The higher the parameter value is, the
Value range: -58~-13 Physical value range: -115~-25; step: 2 (-58:-115; -57:-113; ...; -13:-25 ) Physical unit: dBm Content: The minimum required RX threshold corresponding to CPICH RSCP. The UE can camp on the cell only when the measured CPICH RSCP is greater than the value of this parameter. The setting of Qrxlevmin should be related to Qqualmin. The higher the parameter is, the more difficult it is for the UE to reside in the cell. The lower parameter is, the easier it is for the UE to reside in the cell, but it is possible that the UE cannot receive the system messages that are sent through the PCCPCH. For detailed information, refer to 3GPP TS 25.304. Recommended value: -58
Value range: -50~33 Physical unit: dBm Content: The maximum allowed uplink transmit power of a UE in the cell, which is related to the network planning. For detailed information, refer to 3GPP TS 25.304. Recommended value: 24
Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring time
Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for RSSI measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value of the parameter, the higher the probability of doing so. Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value the parameter, the higher the probability of doing so. Recommended value (default value): 0
0:Always if acceptable1:-28dB 2:-24dB 3:-20dB 4:-16dB15:28dB
0:-20dB, 1:-6dB, 2:-18, 3:-8dB, 4:-16dB, 5:-10dB, 6:-14dB, 7:-12dB
search below 0 : -98dBm/ 1: -94 /2: -90/ 5:-78/ 6: -74 / 7: Always
search below 0 : -98dBm/ 1: -94 /2: -90/ 5:-78/ 6: -74 / 7: Always
5/30/2014 HUAWEI Confidential Page18of80
231509060.xls.ms_office Security Level:
5/30/2014 HUAWEI Confidential Page19of80
231509060.xls.ms_office Security Level:
Value range: -58~-13 Physical value range: -115~-25; step: 2 (-58:-115; -57:-113; ...; -13:-25 ) Physical unit: dBm Content: The minimum required RX threshold corresponding to CPICH RSCP. The UE can camp on the cell only when the measured CPICH RSCP is greater than the value of this parameter. The setting of Qrxlevmin should be related to Qqualmin. The higher the parameter is, the more difficult it is for the UE to reside in the cell. The lower parameter is, the easier it is for the UE to reside in the cell, but it is possible that the UE cannot receive the system messages that are sent through the PCCPCH. For detailed information, refer to 3GPP TS 25.304. Recommended value: -58
Value range: -50~33 Physical unit: dBm Content: The maximum allowed uplink transmit power of a UE in the cell, which is related to the network planning. For detailed information, refer to 3GPP TS 25.304. Recommended value: 24
Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring time
Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for RSSI measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value of the parameter, the higher the probability of doing so. Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value the parameter, the higher the probability of doing so. Recommended value (default value): 0
5/30/2014 HUAWEI Confidential Page20of80
231509060.xls.ms_office Security Level:
5/30/2014 HUAWEI Confidential Page21of80
231509060.xls.ms_office Security Level:
Value range: -58~-13 Physical value range: -115~-25; step: 2 (-58:-115; -57:-113; ...; -13:-25 ) Physical unit: dBm Content: The minimum required RX threshold corresponding to CPICH RSCP. The UE can camp on the cell only when the measured CPICH RSCP is greater than the value of this parameter. The setting of Qrxlevmin should be related to Qqualmin. The higher the parameter is, the more difficult it is for the UE to reside in the cell. The lower parameter is, the easier it is for the UE to reside in the cell, but it is possible that the UE cannot receive the system messages that are sent through the PCCPCH. For detailed information, refer to 3GPP TS 25.304. Recommended value: -58
Value range: -50~33 Physical unit: dBm Content: The maximum allowed uplink transmit power of a UE in the cell, which is related to the network planning. For detailed information, refer to 3GPP TS 25.304. Recommended value: 24
Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring time
Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for RSSI measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value of the parameter, the higher the probability of doing so. Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value the parameter, the higher the probability of doing so. Recommended value (default value): 0
5/30/2014 HUAWEI Confidential Page22of80
231509060.xls.ms_office Security Level:
5/30/2014 HUAWEI Confidential Page23of80
231509060.xls.ms_office Security Level:
Value range: -58~-13 Physical value range: -115~-25; step: 2 (-58:-115; -57:-113; ...; -13:-25 ) Physical unit: dBm Content: The minimum required RX threshold corresponding to CPICH RSCP. The UE can camp on the cell only when the measured CPICH RSCP is greater than the value of this parameter. The setting of Qrxlevmin should be related to Qqualmin. The higher the parameter is, the more difficult it is for the UE to reside in the cell. The lower parameter is, the easier it is for the UE to reside in the cell, but it is possible that the UE cannot receive the system messages that are sent through the PCCPCH. For detailed information, refer to 3GPP TS 25.304. Recommended value: -58
Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring time
Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for RSSI measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value of the parameter, the higher the probability of doing so. Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value the parameter, the higher the probability of doing so. Recommended value (default value): 0
5/30/2014 HUAWEI Confidential Page24of80
231509060.xls.ms_office Security Level:
5/30/2014 HUAWEI Confidential Page25of80
231509060.xls.ms_office Security Level:
Value range: -58~-13 Physical value range: -115~-25; step: 2 (-58:-115; -57:-113; ...; -13:-25 ) Physical unit: dBm Content: The minimum required RX threshold corresponding to CPICH RSCP. The UE can camp on the cell only when the measured CPICH RSCP is greater than the value of this parameter. The setting of Qrxlevmin should be related to Qqualmin. The higher the parameter is, the more difficult it is for the UE to reside in the cell. The lower parameter is, the easier it is for the UE to reside in the cell, but it is possible that the UE cannot receive the system messages that are sent through the PCCPCH. For detailed information, refer to 3GPP TS 25.304. Recommended value: -58
Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring time
Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for RSSI measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value of the parameter, the higher the probability of doing so. Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value the parameter, the higher the probability of doing so. Recommended value (default value): 0
5/30/2014 HUAWEI Confidential Page26of80
231509060.xls.ms_office Security Level:
5/30/2014 HUAWEI Confidential Page27of80
231509060.xls.ms_office Security Level:
Value range: -58~-13 Physical value range: -115~-25; step: 2 (-58:-115; -57:-113; ...; -13:-25 ) Physical unit: dBm Content: The minimum required RX threshold corresponding to CPICH RSCP. The UE can camp on the cell only when the measured CPICH RSCP is greater than the value of this parameter. The setting of Qrxlevmin should be related to Qqualmin. The higher the parameter is, the more difficult it is for the UE to reside in the cell. The lower parameter is, the easier it is for the UE to reside in the cell, but it is possible that the UE cannot receive the system messages that are sent through the PCCPCH. For detailed information, refer to 3GPP TS 25.304. Recommended value: -58
Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring time
Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for RSSI measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value of the parameter, the higher the probability of doing so. Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value the parameter, the higher the probability of doing so. Recommended value (default value): 0
5/30/2014 HUAWEI Confidential Page28of80
231509060.xls.ms_office Security Level:
5/30/2014 HUAWEI Confidential Page29of80
231509060.xls.ms_office Security Level:
Value range: -58~-13 Physical value range: -115~-25; step: 2 (-58:-115; -57:-113; ...; -13:-25 ) Physical unit: dBm Content: The minimum required RX threshold corresponding to CPICH RSCP. The UE can camp on the cell only when the measured CPICH RSCP is greater than the value of this parameter. The setting of Qrxlevmin should be related to Qqualmin. The higher the parameter is, the more difficult it is for the UE to reside in the cell. The lower parameter is, the easier it is for the UE to reside in the cell, but it is possible that the UE cannot receive the system messages that are sent through the PCCPCH. For detailed information, refer to 3GPP TS 25.304. Recommended value: -58
Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring time
Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for RSSI measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value of the parameter, the higher the probability of doing so. Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value the parameter, the higher the probability of doing so. Recommended value (default value): 0
5/30/2014 HUAWEI Confidential Page30of80
231509060.xls.ms_office Security Level:
5/30/2014 HUAWEI Confidential Page31of80
231509060.xls.ms_office Security Level:
Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring time
Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for RSSI measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value of the parameter, the higher the probability of doing so. Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value the parameter, the higher the probability of doing so. Recommended value (default value): 0
5/30/2014 HUAWEI Confidential Page32of80
231509060.xls.ms_office Security Level:
5/30/2014 HUAWEI Confidential Page33of80
231509060.xls.ms_office Security Level:
Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring time
Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for RSSI measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value of the parameter, the higher the probability of doing so. Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle mode Value range: -50~50 Content: Physical unit: dB Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement. The offset is subtracted from the neighboring cell measurement value before cell reselection. In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter can be configured by the network planner according to reality. NOTE: In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE. For details, refer to 3GPP TS 25.331. As for the impact on network performance: The larger the value of the parameter, the lower the probability of selecting neighboring cells. The smaller the value the parameter, the higher the probability of doing so. Recommended value (default value): 0
5/30/2014 HUAWEI Confidential Page34of80
231509060.xls.ms_office Security Level:
5/30/2014 HUAWEI Confidential Page35of80
231509060.xls.ms_office Security Level:
Value range: 0~20 Physical value range: 0~40; step: 2 Physical unit: dB Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling and the consumption of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow fading as well as ensuring time
Value range: {{0~20},{255}} Physical value range: 0~40; step: 2 Physical unit: dB. Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. This parameter is not configured when its value is 255. According to the R regulation, the current serving cell involves in cell selection after the measurement value is added with the hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselection, which is caused by the slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location updates (idle mode), URA updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network signaling
5/30/2014 HUAWEI Confidential Page36of80
List Cell Selection And Reselection Information
-----------------------------------------------
Hysteresis 2 for idle mode[2dB] 1
Hysteresis 2 for connect mode[2dB] 1
Non-HCS indicator NOT_CONFIGURED
Non-HCS max TCR[s] <NULL>
Non-HCS NCR <NULL>
Non-HCS TCR max hysteresis[s] <NULL>
Delta Min Rx level <NULL>
Cell Sel-reselection quality measure CPICH Ec/N0
Hysteresis 1 for idle mode[2dB] 2
Hysteresis 1 for connect mode[2dB] 2
Reselection delay time[s] 1
Min quality level[dB] -18
Min Rx level[2dBm] -58
Min Rx level Extend Support FALSE
Max allowed UE UL TX power[dBm] 24
Intra-freq cell reselection threshold for idle mode[2dB] 5
Inter-freq cell reselection threshold for idle mode[2dB] 4
Intra-freq cell reselection threshold for connect mode[2dB] 5
Inter-freq cell reselection threshold for connect mode[2dB] 4
Inter-RAT cell reselection threshold[2dB] 2
Speed dependent scaling factor for reselection delay 255
Inter-freqency scaling factor for reselection delay 255
Inter-RAT scaling factor for reselection delay 255
Hysteresis 1 for UE in CELL_PCH or URA_PCH state[dB] 255
Hysteresis 1for UE in CELL_FACH state[dB] 255
Hysteresis 2 for UE in CELL_PCH or URA_PCH state[dB] 255
Hysteresis 2 for UE in CELL_FACH state[dB] 255
Reselection delay time for UE in PCH state[s] 255
Reselection delay time for UE in CELL_FACH state[0.2s] 255
10 dB -8
8 dB -10 5
10 dB -8
8 dB -10 5
4 dB -14
S -Criteria
Parameter ID Parameter Name
Set Call Control UTRAN System Message Parameters of Cell(SET GCELLCCUTRANSYS)
MSCVER MSC Version Indication
MEASURETYPE Measurement Report Type
GSMFREQCNUM Serving Band Reporting
IDTYPE Index Type
CELLID Cell Index
CELLNAME Cell Name
FDDRSCPMIN FDD RSCP Min.
QI Qsearch I
QCI Qsearch C Initial
FDDQOFF FDD Q Offset
FDDQMIN FDD Qmin
FDDRSCPMIN FDD RSCP Min.
FDDREP FDD REP QUANT
FDDFREQCNUM FDD Multirate Reporting
SEARCH3G 3G Search PRIO
INVALBSICEN Invalid BSIC Reporting
FDDQMIN FDD Qmin
FDDQMINOFFSET FDD Qmin Offset
QP Qsearch P
QSEARCHC Qsearch C
CELL900OFF 900 Reporting Offset
CELL900THRED 900 Reporting Threshold
SCALEORDER SCALE_ORDER
CELL1800OFF 1800 Reporting Offset
CELL1800THRED 1800 Reporting Threshold
FDDCELLOFF FDD Reporting Offset
CELL900THRED 900 Reporting Threshold
TDDCELLOFF TDD Reporting Offset
FDDCELLTHRED FDD Reporting Threshold
TDDCELLRESELDIV TDD Cell Reselect Diversity
BESTTDDCELLNUM Best TDD Cell Number
FDDCELLOFF FDD Reporting Offset
TDDMIPROHIBIT TDD MI System INFO Broadcasting Prohibit
TDDMIOPTIMIZEDALLOWED TDD MI System Information Optimized
TDDCELLOFF TDD Reporting Offset
TDDCELLTHRED TDD Reporting Threshold
TDDSIOPTIMIZEDALLOWED TDD System Information Optimized Allowed
TDDMIOPTIMIZEDALLOWED TDD MI System Information Optimized
POS2QUATER 2Quater Message Transmission Channel
Parameter Description
Meaning: Type of an index
GUI Value Range: BYNAME(By Name), BYID(By Index)
Actual Value Range: BYNAME, BYID
Unit: None
Default Value: None
Recommended Value: None
Meaning: Index of a cell, uniquely identifying a cell in a BSC
GUI Value Range: 0~2047
Actual Value Range: 0~2047
Unit: None
Default Value: None
Recommended Value: None
Meaning: Name of a cell, uniquely identifying a cell in a BSC
GUI Value Range: None
Actual Value Range: 1~64 characters
Unit: None
Default Value: None
Recommended Value: None
Meaning: Protocol version of the MSC that is connected to the BSC. The supported signaling varies with the
protocol versions.
GUI Value Range: R98_or_below(R98 or below), R99_or_above(R99 or above)
Actual Value Range: R98_or_below, R99_or_above
Unit: None
Default Value: None
Recommended Value: R98_or_below
Meaning: Type of the measurement report (MR) reported by the MS
GUI Value Range: EnhMeasReport(Enhanced Measurement Report), ComMeasReport(Common Measurement
Report)
Actual Value Range: EnhMeasReport, ComMeasReport
Unit: None
Default Value: None
Recommended Value: ComMeasReport
Meaning: Number of neighboring cells that meet the following conditions: If "MBR" is indicated in a system
message, the MS reports the number of neighboring cells at each frequency band. If the MS reports the number
of neighboring cells at the same frequency band of the serving cell, it can report a maximum of the value of this
parameter.
These neighboring cells must meet the following requirements:
1. The receive levels of the neighboring cells must be higher than 900 Reporting Threshold or 1800
Reporting Threshold.
2. The BSIC of a neighboring cell must be valid.
3. The signals of the neighboring cells must be the strongest among all the neighboring cells at the same
frequency band.
GUI Value Range: 0~3
Actual Value Range: 0~3
Unit: None
Default Value: None
Recommended Value: 3
Set Call Control UTRAN System Message Parameters of Cell(SET GCELLCCUTRANSYS)
Meaning: This parameter specifies the level threshold for cell reselection in idle mode. In idle mode, if the signal
level of the serving cell is below [0, 7] or above [8, 15], the MS starts to search for 3G cells. For example, if this
parameter is set to 5 and if the signal level of the serving cell is lower than 5, the MS starts to search for 3G
cells; if this parameter is set to 10 and if the signal level of the serving cell is above 10, then the MS starts to
search for 3G cells. The values of this parameter correspond to the following decibel values: 0: -98 dBm
1: -94 dBm 2: -90 dBm
3: -86 dBm 4: -82 dBm
5: -78 dBm 6: -74 dBm 7: (always), that is, the MS keeps searching for 3G cells 8: -78 dBm
9: -74 dBm 10: -70 dBm 11: -66 dBm 12: -62 dBm 13: -58 dBm 14: -54 dBm 15: Positive infinity(never), that is,
the MS does not search for 3G cells
GUI Value Range: 0~15
Actual Value Range: -98, -94, -90, -86, -82, -78, -74, (always), -78, -74, -70, -66, -62, -58, -54, Positive
infinity(never)
Unit: None
Default Value: None
Recommended Value: 15
Meaning: This parameter specifies the threshold of the signal level for cell reselection in connection mode
before "Qsearch C" is obtained.
GUI Value Range: Use_Qsearch_I(Use Qsearch_I), Always(Always)
Actual Value Range: Use_Qsearch_I, Always
Unit: None
Default Value: None
Recommended Value: Use_Qsearch_I
Meaning: This parameter specifies one of the thresholds of the signal level for 3G cell reselection.
A FDD cell becomes a candidate cell if all the following conditions are met for five consecutive seconds:
1.Receive level of the FDD cell > Average receive level of the current serving cell + FDD Q offset;
The FDD cell meets the following condition in the case of any neighboring 2G cell: Receive level of the FDD cell
> Receive level of any neighboring 2G cell + FDD Q offset;
2. Ec/No of the FDD cell > FDD Qmin - FDD Qmin Offset;
3. Receive level of the FDD cell > "RSCP Threshold";
If multiple FDD cells meet the preceding conditions, the MS reselects the cell with the strongest receive level.
See 3GPP TSs 45.008 and 25.304.
The values of this parameter correspond to the following decibel values:
0: - (always select a cell if acceptable)
1: -28 dB,
2: -24 dB,
...
15: 28 dB.
GUI Value Range: 0~15
Actual Value Range: Negative infinity, -28~28, step: 4
Unit: dB
Default Value: None
Recommended Value: 8
Meaning: Minimum level threshold of UTRAN cell reselection. During the cell reselection decision from a GSM
cell to a FDD cell, this parameter is used to calculate the RSCP threshold of the target cell. A FDD cell becomes
a candidate cell if all the following conditions are met for five consecutive seconds:
1.Receive level of the FDD cell > Average receive level of the current serving cell + FDD Q offset;
The FDD cell meets the following condition in the case of any neighboring 2G cell: Receive level of the FDD cell
> Receive level of any neighboring 2G cell + FDD Q offset;
2. Ec/No of the FDD cell > FDD Qmin - FDD Qmin Offset;
3. Receive level of the FDD cell > "RSCP Threshold";
If multiple FDD cells meet the preceding conditions, the MS reselects the cell with the strongest receive level.
See 3GPP TSs 45.008 and 25.304.
The values of this parameter correspond to the following decibel values:
0 = -114 dBm,
1 = -112 dBm,
2 = -110 dBm,
...
14 = -86 dBm,
15 = -84 dBm.
GUI Value Range: 0~15
Actual Value Range: -114~-84, step: 2
Unit: dBm
Default Value: None
Recommended Value: 6
Meaning: This parameter specifies whether Ec/No or RSCP is used for the measurement report on a FDD cell.
Ec/No stands for the signal-to-noise ratio. RSCP stands for the received signal code power.
GUI Value Range: RSCP(RSCP), EcN0(Ec/N0)
Actual Value Range: RSCP, EcN0
Unit: None
Default Value: None
Recommended Value: RSCP
Meaning: Number of UTRAN FDD cells that should be included in measurement report
GUI Value Range: 0~3
Actual Value Range: 0~3
Unit: None
Default Value: None
Recommended Value: 2
Meaning: This parameter specifies one of the parameters for FDD cell reselection.
A FDD cell becomes a candidate cell if all the following conditions are met for five consecutive seconds:
1.Receive level of the FDD cell > Average receive level of the current serving cell + FDD Q offset;
The FDD cell meets the following condition in the case of any neighboring 2G cell: Receive level of the FDD cell
> Receive level of any neighboring 2G cell + FDD Q offset;
2. Ec/No of the FDD cell > FDD Qmin - FDD Qmin Offset;
3. Receive level of the FDD cell > "RSCP Threshold";
If multiple FDD cells meet the preceding conditions, the MS reselects the cell with the strongest receive level.
See 3GPP TSs 45.008 and 25.304.
The values of this parameter correspond to the following decibel values:
0: -20 dB,
1: -6 dB,
2: -18 dB,
3: -8 dB,
4: -16 dB,
5: -10 dB,
6: -14 dB,
7: -12 dB.
GUI Value Range: 0~7
Actual Value Range: -20, -6, -18, -8, -16, -10, -14, -12
Unit: dB
Default Value: None
Recommended Value: 0
Meaning: Offset of the minimum threshold for Ec/No during a FDD cell reselection.
A FDD cell becomes a candidate cell if all the following conditions are met for five consecutive seconds:
1.Receive level of the FDD cell > Average receive level of the current serving cell + FDD Q offset;
The FDD cell meets the following condition in the case of any neighboring 2G cell: Receive level of the FDD cell
> Receive level of any neighboring 2G cell + FDD Q offset;
2. Ec/No of the FDD cell > FDD Qmin - FDD Qmin Offset;
3. Receive level of the FDD cell > "RSCP Threshold";
If multiple FDD cells meet the preceding conditions, the MS reselects the cell with the strongest receive level.
See 3GPP TSs 45.008 and 25.304.
GUI Value Range: 0~7
Actual Value Range: 0~7
Unit: dB
Default Value: None
Recommended Value: 0
Meaning: This parameter specifies one threshold of the signal level for cell reselection in packet transfer mode.
In packet transfer mode, if the signal level of the serving cell is below [0, 7] or above [8, 15], the MS starts to
search for 3G cells. For example, if this parameter is set to 5 and if the signal level of the serving cell is lower
than 5, the MS starts to search for 3G cells; if this parameter is set to 10 and if the signal level of the serving cell
is above 10, then the MS starts to search for 3G cells. The values of this parameter correspond to the following
decibel values: 0: -98 dBm 1: -94 dBm ... 6: -74 dBm 7: (always) 8: -78 dBm 9: -74 dBm ... 14: -54 dBm
GUI Value Range: 0~15
Actual Value Range: -98, -94, -90, -86, -82, -78, -74, (always), -78, -74, -70, -66, -62, -58, -54, Positive
infinity(never)
Unit: None
Default Value: None
Recommended Value: 15
Meaning: Whether to allow the MS to search for a 3G cell when the BSIC must be decoded
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES
Meaning: Whether a measurement report can contain the information about a cell with an invalid BSIC. The cell
with an invalid BSIC is an unconfigured neighboring cell.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: NO
Meaning: This parameter indicates that when the MS reports the EMR, it adds the value of this parameter to the
received signal level, and then converts the result into the RXLEV value. For details, see GSM Rec. 05.08.
If the SCALE_Order reported by the MS is 10 dBm, level values 0-63 map with -100 dBm to -37 dBm.
If the SCALE_Order reported by the MS is 0 dBm, level values 0-63 map with -110 dBm to -47 dBm.
If the SCALE_Order reported by the MS is Automatic, the MS chooses the least SCALE while ensuring that the
MS can report the most strong level.
GUI Value Range: ADD0dB(+0dB), ADD10dB(+10dB), Automatic(Automatic)
Actual Value Range: ADD0dB, ADD10dB, Automatic
Unit: None
Default Value: None
Recommended Value: ADD0dB
Meaning: In connection mode, if the signal level is below [0-7] or above [8-15], the MS starts to search for 3G
cells. For example, if this parameter is set to 5 and if the signal level of the serving cell is lower than 5, the MS
starts to search for 3G cells; if this parameter is set to 10 and if the signal level of the serving cell is above 10,
then the MS starts to search for 3G cells. 0: -98 dBm
1: -94 dBm
...
6: -74 dBm
7: (always)
8: -78 dBm
9: -74 dBm
...
14: -54 dBm
15: Positive infinity (never)
GUI Value Range: 0~15
Actual Value Range: -98, -94, -90, -86, -82, -78, -74, (always), -78, -74, -70, -66, -62, -58, -54, Positive
infinity(never)
Unit: None
Default Value: None
Recommended Value: 15
Meaning: Offset applied to the receive level of a GSM900 cell in the measurement report before prioritizing cells
by frequency bands. Before cells are sequenced by priority, according to frequencies, the value of this
parameter must be added to the receive level value in the measurement report of the cells at the 900 MHz
frequency.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
7: 42 dB
GUI Value Range: 0~7
Actual Value Range: 0~42, step: 6
Unit: dB
Default Value: None
Recommended Value: 0
Meaning: Threshold of the measurement report of the cells at the 900 MHz frequency. The measurement report
is valid only when the receive level in the measurement report of the GSM900 cell exceeds this threshold. After
being filtered, the measurement report is used for prioritizing the cells. The value 7 means infinite:
0: 0 dB
1: 6 dB
...
6: 36 dB
7: positive infinity
GUI Value Range: 0~7
Actual Value Range: 0~36, Positive infinity, step: 6
Unit: dB
Default Value: None
Recommended Value: 0
Meaning: Offset of the measurement report of the cells at the 1800 MHz frequency. Before cells are sequenced
by priority, according to frequencies, the value of this parameter must be added to the receive level value in the
measurement report of the cells at the 1800 MHz frequency.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
7: 42 dB
GUI Value Range: 0~7
Actual Value Range: 0~42, step: 6
Unit: dB
Default Value: None
Recommended Value: 0
Meaning: Threshold of the measurement report of the cells at the 1800 MHz frequency. When the receive level
value in the measurement report of the cells at the 1800 MHz frequency exceeds the value of this parameter,
the report takes effect. After being filtered, the measurement report is used for priority sequencing of cells.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
6: 36 dB
7: positive infinity
GUI Value Range: 0~7
Actual Value Range: 0~36, Positive infinity, step: 6
Unit: dB
Default Value: None
Recommended Value: 0
Meaning: Offset of a FDD cell report.
When the priority of a 3G cell is sequenced, the value of this parameter be added to the receive level of the 3G
cell in the measurement report.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
7: 42 dB
GUI Value Range: 0~7
Actual Value Range: 0~42, step: 6
Unit: dB
Default Value: None
Recommended Value: 0
Meaning: Threshold of a FDD cell report.
When the receive level value in the measurement report of a 3G cell exceeds the value of this parameter, the
measurement report takes effect. After the valid measurement report is filtered, the 3G cell joins the cell priority
sequence.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
6: 36 dB
7: positive infinity
GUI Value Range: 0~7
Actual Value Range: 0~36, Positive infinity, step: 6
Unit: dB
Default Value: None
Recommended Value: 0
Meaning: A TDD cell can become a candidate cell only when the average receive level of the TDD cell is
greater than the TDD Cell Reselect Diversity of the serving cell.
The value of this parameter corresponds to the following decibel value:
0: negative infinity
1: -28 dB
2: -24 dB
...
15: 28 dB
GUI Value Range: 0~15
Actual Value Range: Negative infinity, -28~28, step: 4
Unit: dB
Default Value: None
Recommended Value: 8
Meaning: Number of UTRAN TDD cells that should be included in measurement report
GUI Value Range: 0~3
Actual Value Range: 0~3
Unit: None
Default Value: None
Recommended Value: 1
Meaning: When the priority of a TDD cell is ranked, the value of this parameter is added to the receive level of
the TDD cell in the measurement report.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
7: 42 dB
GUI Value Range: 0~7
Actual Value Range: 0~42, step: 6
Unit: dB
Default Value: None
Recommended Value: 0
Meaning: Threshold for determining whether the MR about a TDD cell is valid.
The measurement report is valid if the receive level of the TDD cell in the measurement report is greater than
the value of this parameter. After the valid measurement report is filtered, the TDD cell joins in the cell
prioritization.
The value of this parameter corresponds to the following decibel value:
0: 0 dB
1: 6 dB
...
6: 36 dB
7: positive infinity
GUI Value Range: 0~7
Actual Value Range: 0~36, Positive infinity, step: 6
Unit: dB
Default Value: None
Recommended Value: 0
Meaning: This parameter specifies whether to optimize the system information 2Quater and MI of the TDD
neighboring cell. That is, to add an FDD neighboring cell information before the TDD neighboring cell
information to solve the compatibility problem of some dual-mode MSs.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: NO
Meaning: This parameter specifies whether to send the system information MI which contains the 3G
neighboring cell information in the TDD neighboring cell. The value YES(YES) indicates that the MI is sent, and
the value NO(NO) indicates that the MI is not sent.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: NO
Meaning: This parameter specifies whether the TDD MI system information optimized function is enabled.
When this parameter is set to NO and TDD System Information Optimized Allowed is set to YES, the MI
system information issued in the TDD scenario does not carry neighboring cell scrambling codes. In other
scenarios, the MI system information carries neighboring cell scrambling codes.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: NO
Meaning: Whether to transmit the 2Quater message on the BCCH Norm channel or the BCCH Ext channel
GUI Value Range: BCCHNorm(BCCHNorm), BCCHExt(BCCHExt)
Actual Value Range: BCCHNorm, BCCHExt
Unit: None
Default Value: None
Recommended Value: BCCHNorm
Parameter ID Parameter Name
Add 3G External Cell(ADD GEXT3GCELL)
RNCID RNC ID
MNC MNC
LAC Cell LAC
CI Cell CI
EXT3GCELLID Cell Index
EXT3GCELLNAME Cell Name
MCC MCC
UTRANCELLTYPE Utran Cell Type
DF DL UARFCN
SCRAMBLE Scrambling Code or Cell
Parameter Id
DIVERSITY Diversity
RNCID RNC ID
RNCINDEX Neighboring RNC Index
CELLLAYER Layer of the cell
TDDRSCPQUALTHRSH PS TDD RSCP Quality
Threshold
RSCPTHRES RSCP Threshold for Layer of
3G Cell
MINECNOTHRES Min Ec/No threshold
FDDECQUALTHRSH PS FDD Ec/No Quality
Threshold
FDDRSCPQUALTHRSH PS FDD RSCP Quality
Threshold
UTRANCELLTYPE Utran Cell Type
SYNCCASE Sync case
ECNOTHRES Ec/No Threshold for Layer Of
3G Cell
RA Route Area
LoadHoEnExt3G Load Handover Support
LoadAccThres Load handover Load Accept
Threshold
OPNAME Operator Name
RSCPTHRES RSCP Threshold for Layer of
3G Cell
MINRSCPTHRES Min RSCP threshold
Parameter Description
Meaning: ID of the cell. The cell ID cannot conflict with other cell IDs in the BSC. The cells in the
BSC are numbered sequentially.
GUI Value Range: 5048~8047
Actual Value Range: 5048~8047
Unit: None
Default Value: None
Recommended Value: None
Meaning: Name of the cell
GUI Value Range: None
Actual Value Range: 1~64 characters
Unit: None
Default Value: None
Recommended Value: None
Meaning: Mobile country code. This parameter identifies the country where a mobile subscriber is
located, for example, the Chinese MCC is 460.
GUI Value Range: None
Actual Value Range: 3 digit
Unit: None
Default Value: None
Recommended Value: None
Meaning: Mobile network code. This parameter identifies the public land mobile network (PLMN) to
which a mobile subscriber belongs.
GUI Value Range: None
Actual Value Range: 2~3 digit
Unit: None
Default Value: None
Recommended Value: None
Meaning: Location area code (LAC). MSs can freely move in the local location area with no need of
location update. Reasonable local allocation can effectively lighten the signaling load and improve
the call completion rate.
Can be input in hexadecimal format. The hexadecimal format is H'****, for example, H'1214.
GUI Value Range: 1~65533, 65535
Actual Value Range: 1~65533, 65535
Unit: None
Default Value: None
Recommended Value: None
Meaning: Identity code of a cell, A cell is a wireless coverage area identified by a base station
identity code and a global cell identification.
Can be input in hexadecimal format. The hexadecimal format is H'****, for example, H'1214.
GUI Value Range: 0~65535
Actual Value Range: 0~65535
Unit: None
Default Value: None
Recommended Value: None
Meaning: RNC ID of a 3G external cell. The value of this parameter must be consistent with the
data configuration at the RNC.
Add 3G External Cell(ADD GEXT3GCELL)
GUI Value Range: 0~4095
Actual Value Range: 0~4095
Unit: None
Default Value: None
Recommended Value: None
Meaning: Internal index of a neighboring RNC. This parameter is set to 255 when the neighboring
RNC that serves the 3G external neighbor is not configured. You can use the LST GNRNC
command to check whether the neighboring RNC is configured.
GUI Value Range: 0~16, 255
Actual Value Range: 0~16, 255
Unit: None
Default Value: 255
Recommended Value: 255
Meaning: Layer of the cell. If the layer of the cell is lower, it is more likely that a handover to the cell
will be triggered.
GUI Value Range: 1, 2, 3, 4
Actual Value Range: 1, 2, 3, 4
Unit: None
Default Value: 3
Recommended Value: 3
Meaning: Downlink frequency of the external 3G cell
GUI Value Range: 0~16383
Actual Value Range: 0~16383
Unit: None
Default Value: None
Recommended Value: None
Meaning: Scrambling code of a 3G cell. The scrambling code is used to differentiate terminals or
cells. It is used after spread spectrum. Therefore, it does not change the bandwidth of signals, but
only distinguishes the signals from different sources. Through scrambling, multiple transceivers can
use the same codes for spread spectrum. Scrambling is used to distinguish terminals on the uplink
and to distinguish cells on the downlink.
GUI Value Range: 0~511
Actual Value Range: 0~511
Unit: None
Default Value: None
Recommended Value: 0
Meaning: Whether to activate transmit diversity on the common channel of a 3G cell
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: None
Meaning: This parameter specifies the type of a 3G cell. A cell type can be Frequency Division
Duplex (FDD) or Time Division Duplex (TDD).
GUI Value Range: FDD(FDD), TDD(TDD)
Actual Value Range: FDD, TDD
Unit: None
Default Value: None
Recommended Value: None
Meaning: Synchronization status. This parameter is used to identify different 3G cells. This
parameter should be same with the configuration of 3G cells.
GUI Value Range: SyncCase1(Sync case 1), SyncCase2(Sync case 2)
Actual Value Range: SyncCase1, SyncCase2
Unit: None
Default Value: None
Recommended Value: None
Meaning: Threshold for determining the layer of the 3G neighbor cell. If the Ec/No of the 3G
neighbor cell is less than this threshold, the neighbor cell is set to the lowest layer (layer 5).
GUI Value Range: 0~49
Actual Value Range: 0~49
Unit: dB
Default Value: 30
Recommended Value: 30
Meaning: Selects 3G candidate cells. If the measured value of a 3G neighboring cell is lower than
this threshold, the 3G neighboring cell will be removed from among the 3G candidate cells.
GUI Value Range: 0~49
Actual Value Range: 0~49
Unit: dB
Default Value: 10
Recommended Value: 10
Meaning: Minimum Ec/No of the 3G FDD cell candidate
GUI Value Range: 0~49
Actual Value Range: 0~49
Unit: dB
Default Value: 10
Recommended Value: 10
Meaning: Minimum RSCP of the 3G FDD cell candidate
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: None
Default Value: 10
Recommended Value: 10
Meaning: Minimum RSCP quality threshold that the TDD 3G candidate cell must reach
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: None
Default Value: 10
Recommended Value: 10
Meaning: This parameter determines the layers of 3G neighboring cells. If the measured value of a
3G neighboring cell is lower than this threshold, the 3G neighboring cell is positioned at the bottom
layer, that is, layer 4.
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Default Value: 30
Recommended Value: 30
Meaning: Selects 3G candidate cells. If the measured value of a 3G neighboring cell is lower than
this threshold, the 3G neighboring cell will be removed from among the 3G candidate cells.
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Default Value: 10
Recommended Value: 10
Meaning: Indicates that if a 3G neighboring cell supports load handovers, the BSC adds the load
information of the local cells in the signaling procedures related to this neighboring cell.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: NO
Recommended Value: NO
Meaning: If the load of a cell is lower than the value of this parameter, the cell can admit the users
handed over from other cells with higher load. Otherwise, the cell rejects such users.
GUI Value Range: 0~100
Actual Value Range: 0~100
Unit: per cent
Default Value: 80
Recommended Value: 80
Meaning: Name of the operator. This parameter uniquely identifies an operator
GUI Value Range: None
Actual Value Range: 0~255 characters
Unit: None
Default Value: None
Recommended Value: None
Meaning: The NS performs location management based on routing areas during GPRS packet
services. Each routing area has a routing area identifier.
GUI Value Range: 0~255
Actual Value Range: 0~255
Unit: None
Default Value: 0
Recommended Value: 0
Set Calling Process State Protection Timers(SET STATETIMER)
Note
The retransmit mechanism will be used if the signaling is sent by adopting RLC UM on Uu interface during channel handover.In this case, the setting of the corresponding waiting response timer for UE does not work.(For example, when the channel change from DCH to FACH or the channel change from FACH to DCH, the timer does not work.)
The retransmit timer is 2 seconds. The RB reconfiguration message may retransmit three times when the timer expires.
Parameter
ID Name
RrcUeRspTmr RRC UE response timer
RrcIuRelCmdTmr RRC Iu release command timer
RrcRelRetranTmr RRC release retransmission timer
RrcPaingType1Tmr RRC paging type 1 response timer
RrcInitDtTmr RRC initial DT timer
RrcRlcAckCmpTmr
RRC RLC completion
acknowledgement timer
RbSetupRspTmr Wait RB setup response timer
UeCapEnqRspTmr UE capability enquiry response timer
UeCapEnqRspTmr UE capability enquiry response timer
RbRecfgRspTmr Wait RB reconfiguration response timer
RbRelRspTmr Wait RB release response timer
RlSetupRspTmr RL setup response timer
RlRecfgReadyTmr RL reconfiguration timer
RlRelRspTmr RL release timer
RlRstrTmr RL restoration timer
DrlAal2EstIndTmr
DRL AAL2 establishment indication
timer
DrlRecfgCmitTmr DRL reconfiguration commit timer
DrlRecfgCmitTmr DRL reconfiguration commit timer
HoCellUpdateRspTmr HO cell update response timer
HoPagingRspTmr HO paging response timer
HoRelocReqTmr HO relocation request timer
HoAsuTmr HO active set update response timer
HoWtTrchRecfgRspTmr
HO wait timer for TrCH or RB
reconfiguration response
HoPhychRecfgTmr HO PhyCh reconfiguration timer
RelocCmdTmr Relocation Command timer
RelocIuRelCmdTmr Relocation Iu release command timer
RelocIuRelCmdTmr Relocation Iu release command timer
RelocDataFwdTmr Relocation data forwarding timer
RelocAnotherTmr Relocation another request timer
RelocCommitTmr Relocation commit timer
RelocMobilConfTmr
Relocation mobile info confirmation
timer
RelocPhychRecfgTmr Relocation PhyCh reconfiguration timer
RelocUtranHoCmpTmr
Relocation Inter-RAT HO completion
timer
RelocFailIuRelCmdTmr
Relocation failed Iu release command
timer
SysHoPsResumeTmr PS resume timer after SYSHO
Example
Set the timer used to wait for the response to RRC connection setup as 5000 ms.
SET STATETIMER: RrcUeRspTmr=5000;
RRC security mode completion timer
UE counter check response timer
CmchRsrcRspTmr CMCH RSRC response timer
IuCSRelNoRABTmr Iu CS Release protection timer
RrcSecrtModeCmpTmr
IuPSRelNoRABTmr Iu PS Release protection timer
RrcConnRejWaitTmr
Wait Time In RRC Connection Reject
Message
UeCntCheckRspTmr
Set Calling Process State Protection Timers(SET STATETIMER)
The retransmit mechanism will be used if the signaling is sent by adopting RLC UM on Uu interface during channel handover.In this case, the setting of the corresponding waiting response timer for UE does not work.(For example, when the channel change from DCH to FACH or the channel change from FACH to DCH, the timer does not work.)
The retransmit timer is 2 seconds. The RB reconfiguration message may retransmit three times when the timer expires.
Description Network
Description:A timer used to wait for RRC connection setup complete message from UE in RRC
procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer used to wait for the Iu release command message in RRC procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer used to retransmit the RRC CONNECTION RELEASE message to UE.
GUI value range:1~5000
Actual value range:1~5000
Unit:ms
Default value:-
Recommended Value:350
Description:A timer used to wait for the response to paging type 1 in RRC procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer used to wait for initial direct transmission.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer used to wait for the acknowledgement of radio link control (RLC) completion in
RRC procedure.
GUI value range:1~3000
Actual value range:1~3000
Unit:ms
Default value:-
Recommended Value:1000
Description:A timer to RNC wait for the RB setup response from UE in the RB procedure.
GUI value range:300~10000
Actual value range:300~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer used to wait UE capability enquiry response .
5000
5000
350
5000
5000
1000
5000
5000
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer used to wait for the RB reconfiguration response from UE in the RB
procedure.
GUI value range:300~10000
Actual value range:300~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the RB release response from UE in the RB procedure.
GUI value range:300~10000
Actual value range:300~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the response to radio link setup request in the radio link
procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the response to radio link reconfiguration prepare in the radio
link procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the response to radio link deletion request in the radio link
procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for radio link restoration indication in the radio link procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to DRNC wait for AAL2 setup indication.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to DRNC wait for radio link reconfiguration commit.
GUI value range:1~10000
5000
5000
5000
5000
5000
5000
10000
5000
5000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the response to the cell update confirm from UE in forward
handover procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for paging response in forward handover procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for relocation request in forward handover procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the response to active set update in soft handover procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the response to the TrCH reconfiguration or RB
reconfiguration response from UE in hard handover procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the response to physical channel reconfiguration in hard
handover procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the relocation command message in relocation procedure.
GUI value range:1~20000
Actual value range:1~20000
Unit:ms
Default value:-
Recommended Value:10000
Description:A timer to RNC wait for the Iu release command message in relocation procedure.
GUI value range:1~60000
5000
5000
5000
5000
5000
5000
5000
10000
45000
Actual value range:1~60000
Unit:ms
Default value:-
Recommended Value:45000
Description:A timer used for data forwarding in relocation procedure.
GUI value range:1~20000
Actual value range:1~20000
Unit:ms
Default value:-
Recommended Value:20000
Description:A timer to RNC wait for another relocation request in relocation procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for rnsap relocation commit message in relocation procedure.
GUI value range:1~20000
Actual value range:1~20000
Unit:ms
Default value:-
Recommended Value:15000
Description:A timer to RNC wait for mobile information confirmation in relocation procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the response to physical channel reconfiguration in relocation
procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for inter-RAT handover completion in relocation procedure.
GUI value range:1~20000
Actual value range:1~20000
Unit:ms
Default value:-
Recommended Value:10000
Description:A timer to RNC wait for Iu release command in the failed relocation procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:3000
Description:A timer to RNC wait for PS RESUME after successful CS InterRAT handover.
GUI value range:1~255
Actual value range:1~255
Unit:min
Default value:-
Recommended Value:10
45000
20000
5000
15000
5000
5000
10000
5000
10
Description:A timer to RNC wait for the response to security mode command from UE in security
mode procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to RNC wait for the response to counter check in security mode procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to SRNC wait for the response to common transport channel resources
request in the Iur common transport channel procedure.
GUI value range:1~10000
Actual value range:1~10000
Unit:ms
Default value:-
Recommended Value:5000
Description:A timer to Iu CS Release protection.
GUI value range:1~65535
Actual value range:1~65535
Unit:s
Default value:-
Recommended Value:300
Description:A timer to Iu PS Release protection.
GUI value range:1~65535
Actual value range:1~65535
Unit:s
Default value:-
Recommended Value:300
Description:Wait time in RRC connection reject message, the time period the UE has to wait
before repeating the rejected procedure of RRC connection.
GUI value range:0~15
Actual value range:0~15
Unit:s
Default value:-
Recommended Value:4
Set the timer used to wait for the response to RRC connection setup as 5000 ms.
300
300
4
5000
5000
5000
The retransmit mechanism will be used if the signaling is sent by adopting RLC UM on Uu interface during channel handover.In this case, the setting of the corresponding waiting response timer for UE does not work.(For example, when the channel change from DCH to FACH or the channel change from FACH to DCH, the timer does not work.)
The retransmit mechanism will be used if the signaling is sent by adopting RLC UM on Uu interface during channel handover.In this case, the setting of the corresponding waiting response timer for UE does not work.(For example, when the channel change from DCH to FACH or the channel change from FACH to DCH, the timer does not work.)

You might also like