You are on page 1of 8

This Document comes in 3 Sections; Section A (Manpower), Section B (Equipment) and Section C (Work

Activities)
Bidder shall fill-up all the three sections accordingly.
Section A : UNIT RATES FOR MANPOWER
The rates quoted in the following table are all-inclusive; including but not limited to the following:
Payroll Costs
WORK SITE allowances
Burdens, Overheads and Premiums
Field Office Consumables and operating costs (communications etc)
Small tools
Personal Protective Equipment
Payroll Costs
Required Safety Training & Certification
Temporary facilities and operating costs
Transportation
Subcontracts Indirect Labour
Subcontracts WORK SITE Management (above foreman level)
Local housing accommodation
The rates shall include all taxes, withholding tax, duties, export duties, royalties, imports and other
charges, with respect to WORK rendered hereunder imposed directly or indirectly, prospectively or retro-
spectively by the Federal and/or Local Government of Malaysia shall be borne by successful
CONTRACTOR.
The rates are applicable only to productive days i.e. not calendar as below :
Rate A - Normal Hour Rate (Monday to Saturday from 7.00am - 7.00pm)= Bidder to quote per table be-
low.
Rate B - Overtime Rate (Monday to Saturday beyond 7.00pm) = multiply 1.5 of Rate A
Rate C - Sunday and Malaysia Public Holiday = multiply 3.0 of Rate A
No. Position
Rate A
Normal rate
(RM/hour)
1 Project Manager
2 Project Coordinator Engineer
3 Planner/Scheduler
4 Procurement Coordinator
5 Document Controller
6 Material Coordinator
7 General clerk
8 HSE Officer
9 HSE Supervisor
10 Site Supervisor (Mechanical/Piping)
11 Site Supervisor (Electrical)
12 Site Supervisor (Instrument)
13 Site Supervisor (Civil & Structural)
14 QC Supervisor
15 QC Inspector
EXHIBIT III - CONTRACT PRICE
No. Position
Rate A
Normal rate
(RM/hour)
16 Technician (Electrical)
17 Technician (Instrument)
18 Chargeman A0
19 Chargeman A1
20 Chargeman A2
21 Chargeman A4
22 Chargeman B0
23 Chargeman B4
24 Wireman PW2
25 Wireman PW4
26 Cable Jointer HV (11KV ~ 33KV)
27 Quantity Surveyor
28 Fitter (mechanical/piping)
29 Fitter (electrical/instrument)
30 Welder (piping)
31 Welder (structural)
32 Welder (confined space)
33 Skilled Worker
34 Rigger
35 Fire Watcher
36 Confined Space Hole Watcher
37 Foreman (All Disciplines)
38 Carpenter
39 Concrete Worker
40 Plasterer
41 Masonry Worker
42 Millwright
43 Iron Worker
44 Insulation Worker
45 Painter
46 Storekeeper
47 Equipment Operator
48 General worker /helper/common labour
49 Security guard
50 Fibre optic splicer/tester
51 Material expeditor
52 JIT Supervisor
53 Scaffolder
SECTION B : UNIT RATES FOR EQUIPMENT
The rates quoted in the following table shall be all-inclusive, including but not limited to the following:
Equipment operator/driver c/w valid certification
Licenses and permits required to mobilize to WORK site, to operate and to maintain the equipment
Maintenance and upkeep of the equipment
Consumables required to operate the equipment
All attachments or accessories required to execute the WORK
No. Description Mob/Demob
Cost (RM)
Daily Rate
(RM)
Weekly Rate
(RM)
Monthly Rate
(RM)
Other Cost
(RM)
1 20T crane - -
2 25T crane - -
3 40T crane - -
4 45T crane - -
5 60T crane - -
6 120T crane - -
7 150T crane - -
8 240T crane - -
9 1T forklift - -
10 2T forklift - -
11 3T forklift - -
12 5T forklift - -
13 1T lorry c - -
14 2T lorry - -
15 3T lorry - -
16 5T lorry - -
17 10T lorry c - -
18 Lorry trailer - -
22 Van - -
23 Pick-up truck (twin cab) - -
24 Backhoe - -
25 Excavator - -
26 Concrete Mixer - -
27
50 KVA Diesel Engine
Generator Set
- -
28
150 KVADiesel Engine
Generator Set
- -
29
250 KVA Diesel Engine
Generator Set
- -
30
Diesel driven welding
machine 400AMP
- -
31 D.C Welding H/C 300 AMP - -
32 D.C. Welding H/C 400AMP - -
33 390 cfm Air compressor - -
34 Water pump 2" - -
35 Water pump 4" - -
36 Portable diesel spotlight - -
No. Description
Mob/Demob
Cost (RM)
Daily Rate
(RM)
Weekly Rate
(RM)
Monthly Rate
(RM)
Other Cost
(RM)
37 Oxy acytelene cutting set - -
38 Cold cutting equipment 2" - -
39 Cold cutting equipment 4" - -
40 Cold cutting equipment 6" - -
41 Cold cutting equipment 8" - -
42 Cold cutting equipment 10" - -
43 Grinder 4" - -
44 Grinder 7" - -
45 Cable puller - -
46 Nut splitter - -
47
Hydraulic Bolt Tensioning (HBT)
machine
- -
48
Hydraulic Torque Wrench
(HTW)
- -
49 PWHT machine - -
50 Hydrojetter - -
51 Welding set - -
52 Hydrotest pump (manual) - -
53 Hydrotest pump (air) - -
54 Scaffolding per m3 - -
55 Walkie-talkie (point to point) - -
56 Fibre optic splicing machine - -
57 Hand drill - -
58 Drill machine - -
59 Coring machine - -
60 Standby rescue boat - -
61 Manlifter/Skylifter - -
62 Chain block with slings - -
63 Oxy acytelene torch set - -
64 Construction cabin 20ft - -
65 Portable gas detector - -
66 Barge - -
67 Barge crane - -
C2. ELECTRICAL WORKS
The following unit prices shall be all-inclusive rates of labour, construction equipment, tools and con-
sumables for the completion of WORKS.
Description Unit Rate Unit Cost Total Cost Section Subtotal Unit Cost Total Cost Section Subtotal
(RM) (D) RM (E)= (A) x (D) RM (RM) (F) (RM) RM (RM)
1 Cable Trench
Excavation of outdoor cable trench including backfilling with sand,
brick compacted soil, and markers as specified:
300 mm wide M3 126.00 63.00
450 mm wide M3 150.00 95.00
1,000 mm wide M3 250.00 180.00
2 Cable Ladder
Supply and installation of perforated hot dip galvanized cable
ladder c/w steel bracket:
150 mm - 300 mm wide M 75.00 184.00 SIZE : 300W X 200 H X 3000L X 2T
900 mm - 1,000 mm wide M 130.00 235.00 SIZE : 1000W X 200 H X 3000L X 2T
3 Lighting Fixtures
Supply and installation and connection of fixtures c/w lamps,
integral and control gear, compensators and accessories as
specified:
250 W SON Street Lighting Fitting No. 475.00 1,000.00
400 W SON Street Lighting Fitting No. 475.00 1,200.00
400 W HPMT Floodlight Normal Fitting No. 475.00 2,500.00
2 x 36 W Explosion proof Flourescent Fitting No. 350.00 1,600.00
2 X 18W Explosion proof Flourescent Fitting No. 350.00 1,500.00
400 W Explosion proof Floodlight Fitting No. 500.00 4,200.00
4 Lighting Poles
Supply and installation and connection of galvanised hinged
column collapsible lighting pole, c/w foundation, bolts, plinth,
mounting brackets etc as specified & 10 m high
No.
1,000.00 2,100.00
5 Underground Cables
11kv -120 -240 mm2 (3 cores
xlpe/lc/pvc/swa/pvc)
m 32.00 606.00 Price excluding cable trench, jointing, termination and testing
6.6kv -120 -240 mm2 (3 cores-single core/3
cores xlpe/lc/pvc/swa/pvc)
m
32.00 560.00 Price excluding cable trench, jointing, termination and testing
0.6/1kv -120 -240 mm2 (3 cores -single core/3
cores xlpe/lc/pvc/swa/pvc)
m
32.00 500.00 Price excluding cable trench, jointing, termination and testing
6 Low Voltage Cable
3C X 2.5mm2 XLPE/PVC/SWA/PVC m 3.50 7.00 Price excluding gland, jointing, termination and testing
3C X 4.0mm2 XLPE/PVC/SWA/PVC m 4.70 9.00 Price excluding gland, jointing, termination and testing
3C X 6.0 mm2 XLPE/PVC/SWA/PVC m 5.30 13.00 Price excluding gland, jointing, termination and testing
3C X 10.0 mm2 XLPE/PVC/SWA/PVC m 5.90 15.00 Price excluding gland, jointing, termination and testing
3C X 16.0 mm2 XLPE/PVC/SWA/PVC m 6.60 23.00 Price excluding gland, jointing, termination and testing
3C X 25.0 mm2 XLPE/PVC/SWA/PVC m 6.90 25.00 Price excluding gland, jointing, termination and testing
3C X 35.0 mm2 XLPE/PVC/SWA/PVC m 13.80 47.00 Price excluding gland, jointing, termination and testing
3C X 50.0 mm2 XLPE/PVC/SWA/PVC m 23.50 62.00 Price excluding gland, jointing, termination and testing
3C X 75.0 mm2 XLPE/PVC/SWA/PVC m 26.20 93.00 Price excluding gland, jointing, termination and testing
3C X 120.0 mm2 XLPE/PVC/SWA/PVC m 31.20 146.00 Price excluding gland, jointing, termination and testing
3C X 185.0 mm2 XLPE/PVC/SWA/PVC m 35.40 224.00 Price excluding gland, jointing, termination and testing
Price excluding gland, jointing, termination and testing
Note: 1 Price are based on Unit rate
REMARKS Total Amount Item No.
Labour Cost Material Cost
C5-3 : Electrical Common Materials
No List of Materials Unit Unit Rate
(RM)
1 33kv -185 mm2 (3 cores xlpe/lc/pvc/swa/pvc) M 550.00
2 11 kv -120 -240 mm2 (3 cores xlpe/lc/pvc/swa/pvc) M 606.00
3 6.6kv -120 -240 mm2 (3 cores-single core/3 cores xlpe/lc/pvc/swa/pvc) M
560.00
4 0.6/1kv -120 -240 mm2 (3 cores -single core/3 cores xlpe/lc/pvc/swa/pvc) M
500.00
5
500v -120 -240 mm2 (Multi core 10 cores single core/3 cores
xlpe/lc/pvc/swa/pvc)
M
TBA
6 3C X 2.5mm2 XLPE/PVC/SWA/PVC M 7.00
7 3C X 4.0mm2 XLPE/PVC/SWA /PVC M 9.00
8 3C X 6.0 mm2 XLPE/PVC/SWA /PVC M 13.00
9 3C X 10.0 mm2 XLPE/PVC/SWA /PVC M 15.00
10 3C X 16.0 mm2 XLPE/PVC/SWA /PVC M 23.00
11 3C X 25.0 mm2 XLPE/PVC/SWA /PVC M 25.00
12 3C X 35.0 mm2 XLPE/PVC/SWA /PVC M 47.00
13 3C X 50.0 mm2 XLPE/PVC/SWA /PVC M 62.00
14 3C X 75.0 mm2 XLPE/PVC/SWA /PVC M 93.00
15 3C X 120.0 mm2 XLPE/PVC/SWA /PVC M 146.00
16 3C X 185.0 mm2 XLPE/PVC/SWA /PVC M 224.00
17 25 mm2 1C PVC Cable Meters M 12.00
18 75 mm2 1C PVC Cable Meters M 27.00
19 95 mm2 1C PVC Cable Meters M 42.40
20 4 -6 mm2 rubberise 3 Core flexible cable Meters M TBA
21 15 -75 mm2 rubberise 4 Core flexible cable Meters M TBA
22 50 -95 mm2 rubberise 4 Core flexible cable Meters M TBA
23 MCB Single Pole 6 -10 Ampere -KA (ABB) pc 26.50
24 MCB Single Pole 15 -25 Ampere -KA (ABB) pc 26.50
25 MCB Single Pole 25 -45 -Ampere -KA (ABB) pc 26.50
26 MCB Double Pole 6 -10 Ampere -KA (ABB) pc 54.00
27 MCB Double Pole 15 -25 Ampere -KA (ABB) pc 54.00
28 MCB Double Pole 25 -45 -Ampere -KA (ABB) pc 54.00
29 MCB Triple Pole 6 -10 Ampere -KA (ABB) pc 80.00
30 MCB Triple Pole 15 -25 Ampere -KA (ABB) pc 80.00
31 MCB Triple Pole 25 -45 -Ampere -KA (ABB) pc 80.00
32
MCCB 3 phase and neutral, complete with Earth Leakage Protection 63
Ampere pieces (Merlin Gerin 63A 4P 36KA)
set
1,200.00
33
MCCB 3 phase and neutral, complete with Earth Leakage Protection 100
Ampere pieces (Merlin Gerin 100A 4P 36KA)
set
1,200.00
34
MCCB 3 phase and neutral, complete with Earth Leakage Protection 150
Ampere pieces (Merlin Gerin 160A 4P 36KA)
set
1,500.00
35
MCCB 3 phase and neutral, complete with Earth Leakage Protection 200
Ampere pieces (Merlin Gerin 200A 4P 36KA)
set
1,800.00
36 MCCB 3 phase and neutral, complete with Earth Leakage Protection set 1,800.00
Note: Material Cost only
Standard General Terms and Conditions
Remarks
No List of Materials Unit Unit Rate
(RM)
250 Ampere pieces (Merlin Gerin 250A 4P 36KA)
37
MCCB 3 phase and neutral, complete with Earth Leakage Protection 400
Ampere pieces (Merlin Gerin 400A 4P 50KA)
set
2,700.00
38
Junction Box Exde increase safety poly carbon, complete with cable
connector 6 X 6 -50 Amp (Rose)
set
1,640.00 We offer Weidmuller 160(H) x 360(W) x 90 (D)
39
Junction Box Exde increase safety poly carbon, complete with cable
connector 10 X 10 -100 Amp (Rose)
set
2,110.00 We offer Weidmuller 160(H) x 560(W) x 90 (D)
40
Junction Box Exde increase safety poly carbon, complete with cable
connector 12 X 12 -200 Amp (Rose)
set
3,350.00 We offer Weidmuller 250(H) x 600(W) x 120 (D)
41
Junction Box Exde increase safety stainless steel complete with cable
connector 12 X 12 -100 Amp terminal connector (Weidmuller)
set
3,900.00 We offer Weidmuller 350(H) x 260(W) x 200 (D)
42
Junction Box Exde increase safety stainless steel, complete with cable
connector 12 X 24 -200 Amp terminal connector (Weidmuller)
set
5,680.00 We offer Weidmuller 550(H) x 350(W) x 200 (D)
43 PVC tape M3
2.00
44 3M PVC tape M3
3.00
45 16 Amp CEAG Wall Mounted Socket Outlet (Model No. : GHG 543 4306 V0) M3
800.00
46 16 Amp CEAG Plug (Model No. : GHG 543 2306 V0) pc
320.00
47
32 Amp 3 phase CEAG Wall Mounted Socket Outlet (Model No. : GHG 532
4406 V0)
pc
230.00
48 32 Amp 3 phase CEAG Plug (Model No. : GHG 532 7406 V0) pc
560.00
49
63 Amp 3 phase CEAG Wall Mounted Socket Outlet (Model No. : GHG 534
1506 V0)
pc
7,700.00
50 63 Amp 3 phase CEAG Plug (Model No. : GHG 534 2506 V0) pc
2,300.00
51 6 mm2 Cable Lug pc
0.50
52 10 mm2 Cable Lug pc
0.50
53 15 mm2 Cable Lug pc
0.50
54 20 mm2 Cable Lug pc
1.00
55 25 mm2 Cable Lug pc 1.00
Note: Material Cost only