CONTENTS

1. TECHNICAL CHANGES 2
2. PART NAMES AND FUNCTIONS2
3. SPECIFICATION3
4. NOISE CRITERIA CURVES4
5. OUTLINES AND DIMENSIONS 5
6. WIRING DIAGRAM 6
7. REFRIGERANT SYSTEM DIAGRAM6
8. SERVICE FUNCTIONS 7
9. MICROPROCESSOR CONTROL 9
10. TROUBLESHOOTING14
11. DISASSEMBLY INSTRUCTIONS26
MSZ-GC22VA -
MSZ-GC25VA -
MSZ-GC35VA -
E1
E1
E1
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
Outdoor unit service manual
MUZ-GCVA Series (OBH469)
MXZ-AVA Series (OB377)
MXZ-8A140A (OC316)
SERVICE MANUAL
Wireless type
Models
No. OBH468
REVISED EDITION-A
INDOOR UNIT
PARTS CATALOG (OBB468)
Revision A:
10.TROUBLESHOOTING has been corrected.
Please void OB468.
OBH468A.qxp 07.2.19 1:53 PM Page 1
2
1
TECHNICAL CHANGES
MSZ-GA22VA - MSZ-GC22VA -
MSZ-GA25VA - MSZ-GC25VA -
MSZ-GA35VA - MSZ-GC35VA -
E1 E1
E1 E1
E1 E1
1. Indoor model has been changed.
PART NAMES AND FUNCTIONS
2
MSZ-GC22VA
MSZ-GC25VA
MSZ-GC35VA
Air outlet
Vertical vane
Air inlet
Operation Indicator
lamp
Front panel
Catechin air filter
Horizontal vane
Remote controller
Remote control
receiving section
Emergency operation switch (E.O. SW)
Air cleaning filter
(Anti-allergy enzyme filter, option)
Line flow fan
Revision A:
10.TROUBLESHOOTING has been corrected.
Color of lead wire (indoor fan motor : sensor part) of 10-5.Trouble criterion of main parts has been corrected.
10-6.ACheck of indoor fan motor has been corrected.
OBH468A.qxp 07.2.19 1:53 PM Page 2
3
SPECIFICATION 3
Fuse
Horizontal vane motor
Varistor
Terminal block
(F11)
(MV)
(NR11)
(TB)
T3.15AL 250V
12V DC
S10K320E3K1(ERZV14D471)
3P
Specifications and rating conditions of main electric parts
NOTE : Test conditions are based on ISO 5151
Cooling : Indoor Dry-bulb temperature 27:Wet-bulb temperature 19:
Outdoor Dry-bulb temperature 35:
Heating : Indoor Dry-bulb temperature 20:
Outdoor Dry-bulb temperature 7:Wet-bulb temperature 6:
Refrigerant piping length (one way): 5m
1 Measured under rated operating frequency.
MSZ-GC25VA MSZ-GC35VA
Single phase
230V,50Hz
0.22
40
0.22
788O295O234
9
4
43
4
KM05B
36/29/22
Cooling

576
462/354/246
1,070
890/720/550
Heating
600
480/378/276
1,100
920/760/600
MSZ-GC22VA Indoor model
Function
Power supply
36/29/21
Cooling

576
462/354/246
1,070
890/720/550
Heating
600
480/378/276
1,100
920/760/600
RC4V18-BA or CA

Cooling
552
444/330/234
1,110
930/740/580
Heating
570
462/354/246
1,140
960/780/600
Air flow(Super High)
Air flow(High/Med./Low)
Running current 1
Power input 1
Fan motor current 1
Model
Dimensions WOHOD
Weight
Air direction
Sound level (Super High)
Sound level (High/Med./Low)
Fan speed (Super High)
Fan speed (High/Med./Low)
Fan speed regulator
Remote controller model
K /h
K /h
A
W
A
mm
kg
dB(A)
dB(A)
rpm
rpm
E
l
e
c
t
r
i
c
a
l
d
a
t
a
Fan motor
S
p
e
c
i
a
l
r
e
m
a
r
k
s
Capacity
ACCESSORIES
1
2
3
4
5
6
7
Installation plate
Installation plate fixing screw 4 o 25 mm
Remote controller holder
Fixing screw for 3 3.5 o 1.6 mm (Black)
Battery (AAA) for remote controller
Wireless remote controller
Felt tape (Used for left or left-rear piping)
1
5
1
2
2
1
1
MSZ-GC22VA
MSZ-GC25VA
MSZ-GC35VA
OBH468A.qxp 07.2.22 11:32 AM Page 3
4
4 NOISE CRITERIA CURVES
MSZ-GC22VA
MSZ-GC25VA
INDOOR UNIT
WALL
MICROPHONE
0.8m
1m
90
80
70
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
O
C
T
A
V
E

B
A
N
D

S
O
U
N
D

P
R
E
S
S
U
R
E

L
E
V
E
L
,

d
B

r
e

0
.
0
0
0
2

M
I
C
R
O

B
A
R
BAND CENTER FREQUENCIES, Hz
COOLING
FUNCTION SPL(dB(A)) LINE
Super High
FAN SPEED
HEATING
Test conditions
Cooling : Dry-bulb temperature 27: Wet-bulb temperature 19:
Heating : Dry-bulb temperature 20:
43
43
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
MSZ-GC35VA
90
80
70
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
O
C
T
A
V
E

B
A
N
D

S
O
U
N
D

P
R
E
S
S
U
R
E

L
E
V
E
L
,

d
B

r
e

0
.
0
0
0
2

M
I
C
R
O

B
A
R
BAND CENTER FREQUENCIES, Hz
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
COOLING
FUNCTION SPL(dB(A)) LINE
Super High
FAN SPEED
HEATING
43
43
OBH468A.qxp 07.2.19 1:53 PM Page 4
5
OUTLINES AND DIMENSIONS
5
Unit : mm
74 59 4
1
.
5
2
1
4
2
3
5
2
5
3
.
5
1
8
.
5
320 335
155 155
2
1
5
4
0
.
5
2
5
4
.
5
59 59 225 225
2
2
9
5
53 607 128
8
1
0
0
137
119
P
i
p
i
n
g
Insulation [35 O.D
Liquid line [6.35 - 0.5 m (Flared connection [6.35)
Gas line [9.52 - 0.43 m (Flared connection [9.52)
Drain hose Insulation [28 O.D Connected part [16 O.D
11 X 26 Oblong hole 11 X 20 Oblong hole
Installation plate
Indoor unit
Wall hole [65 Air in
Air out
Installation plate
Piping
Drain hose
19
1
5
9
58
234 5
788
MSZ-GC22VA
MSZ-GC25VA
MSZ-GC35VA
OBH468A.qxp 07.2.19 1:53 PM Page 5


DIAGRAM ALARMS





N.C.
C.

































TABLE OF RAIL CONNECTION

ORIGEN DESTINO
Equipo Posicion Pin Servicios Color Regleta Nivel Pin
1 Blanco/Naranja A
ALAR. 3 Termostato
3
Baja Temperatura Sala
Naranja
26x4 3
B
1 Blanco/Verde C
ALAR. 2 Termostato
2
Alta Temperatura Sala
Verde
26x4 3
D
1 Blanco/Azul A
ALAR. 1 Rel
3
Fallo A/C 220V
Azul
26x4 4
B
6
6
WIRING DIAGRAM
REFRIGERANT SYSTEM DIAGRAM
7
MSZ-GC22VA
MSZ-GC25VA
MSZ-GC35VA
Indoor
heat
exchanger
Flared connection
Room temperature
thermistor
RT11
Flared connection
Refrigerant pipe [9.52
(with heat insulator)
Refrigerant pipe [6.35
(with heat insulator)
Indoor coil
thermistor
RT12 (main)
Indoor coil
thermistor
RT13 (sub)
Unit : mm
MSZ-GC22VA
MSZ-GC25VA
MSZ-GC35VA
OBH468A.qxp 07.2.19 1:53 PM Page 6
7
SERVICE FUNCTIONS 8
8-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
In this case, to operate each indoor unit individually by each remote controller, P.C. boards of remote controller must be
modified according to the number of the indoor unit.
8-1. TIMER SHORT MODE
For service, set time can be shortened by short circuit of JPG and JPS on the electronic control P.C. board.
The time will be shortened as follows. (Refer to 10-7.)
Set time : 1-minute 1-second
Set time : 3-minute 3-second (It takes 3 minutes for the compressor to start operation. However, the starting time is
shortened by short circuit of JPG and JPS.)
No. 1 unit
No. 2 unit
No. 3 unit
No. 4 unit
1 unit operation
No modification

2 units operation
Same as at left
Solder J1

3 units operation
Same as at left
Same as at left
Solder J2

4 units operation
Same as at left
Same as at left
Same as at left
Solder both J1 and J2
Table 1
How to set the remote controller exclusively for particular indoor unit
After you turn the breaker ON, the first remote controller that sends the signal to the indoor unit will be regarded as the remote
controller for the indoor unit.
The indoor unit will only accept the signal from the remote controller that has been assigned to the indoor unit once they are
set.
The setting will be cancelled if the breaker is turned OFF, or the power supply is shut down.
Please conduct the above setting once again after the power has restored.
How to modify the remote controller P.C. board
Remove batteries before modification.
The board has a print as shown below :
The P.C. board has the print J1 and J2. Solder J1 and J2 according to the number of indoor unit as shown in Table 1.
After modification, press the RESET button.
NOTE : For modification, take out
the batteries and press the
OPERATE/STOP(ON/OFF)
button twice or 3 times at
first.
After modification, put back
the batteries then press
the RESET button.
MSZ-GC22VA
MSZ-GC25VA
MSZ-GC35VA
J2 J1
OBH468A.qxp 07.2.19 1:53 PM Page 7
8
NOTE :
The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the
remote controller.
If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled.
If the unit has been off with the remote controller before power failure, the auto restart function does not work as the
power button of the remote controller is off.
To prevent breaker OFF due to the rush of starting current, systematize other home appliance not to turn ON at the
same time.
When some air conditioners are connected to the same supply system, if they are operated before power failure,
the starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting
current by adding to the system that allows the units to start one by one.
JR07
Indoor electronic
control P.C. board
C
N
1
0
A
C
N
1
1
1
C
N
1
5
1
C
N
1
1
2
8-3. AUTO RESTART FUNCTION
When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed
are memorized by the indoor electronic control P.C. board. AUTO RESTART FUNCTION automatically starts operation
in the same mode just before the shutoff of the main power.
Operation
1 If the main power has been cut, the operation settings remain.
2 After the power is restored, the unit restarts automatically according to the memory.
(However, it takes at least 3 minutes for the compressor to start running.)
How to release AUTO RESTART FUNCTION
1Turn off the main power for the unit.
2Solder the Jumper wire to JR07 on the indoor electronic control P.C. board. (Refer to 10-7.)
OBH468A.qxp 07.2.19 1:53 PM Page 8
9
MICROPROCESSOR CONTROL 9
Once the operation mode is set, the same operation mode can be repeated by simply turning OPERATE/STOP
(ON/OFF) button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to protect system from overload and compressor will not
restart for 3 minutes.
WIRELESS REMOTE CONTROLLER
Operation Indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
INDOOR UNIT DISPLAY SECTION
About 2 : or more
away from
set temperature
Room temperature
About 1 to 2 : from
set temperature
The unit is operating
to reach the set
temperature
The room temperature
is approaching
the set temperature
Standby mode
(only during multi
system operation)
Operation state Indication
Lighted
Not lighted
The following indication applies regardless of shape of the indicator.
Blinking
MSZ-GC22VA
MSZ-GC25VA
MSZ-GC35VA
ON TIMER button
CLOCK SET button
TIME SET buttons
FORWARD button
BACKWARD button
OFF TIMER button

Open the front lid.
RESET button
VANE CONTROL button
Signal transmitting section
Operation display section
Temperature buttons
OPERATE/STOP
(ON/OFF) button
FAN SPEED CONTROL button
OPERATION SELECT button
ECONO COOL button
Indication of
remote controller
model is on back
OBH468A.qxp 07.2.19 1:53 PM Page 9
10
1. Coil frost prevention
Coil frost prevention is as same as COOL mode. (9-1.1.)
2. Low outside temperature operation
Low outside temperature operation is as same as COOL mode. (9-1.2.)
1. Cold air prevention control
When the compressor is not operating or is starting, and the temperature of indoor heat exchanger and/or the room tem-
perature is low or when defrosting is being done, the indoor fan will stop or rotate in Very Low speed.
9-2. DRY ( ) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select DRY mode with OPERATION SELECT button.
(3) The set temperature is determined from the initial room temperature.
9-3. HEAT ( ) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select HEAT mode with OPERATION SELECT button.
(3) Press TEMPERATURE buttons (TOO WARM or TOO COOL button) to select the desired temperature.
The setting range is 16 ~ 31C.
1. Coil frost prevention
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the coil
from frosting.
When the temperature of indoor heat exchanger becomes too low, the coil frost prevention mode works.
The indoor fan operates at the set speed and the compressor stops. This mode continues until the temperature of indoor
heat exchanger rises.
2. Low outside temperature operation
When the outside temperature is lower, low outside temperature operation starts, and the outdoor fan slows or stops.
9-1. COOL ( ) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select COOL mode with OPERATION SELECT button.
(3) Press TEMPERATURE buttons (TOO WARM or TOO COOL button)to select the desired temperature.
The setting range is 16 ~ 31C.
2. High pressure protection
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the con-
densing pressure from increasing excessively.
When the temperature of indoor heat exchanger becomes too high, the high pressure protection works.
The indoor fan operates following the cold air prevention control. This mode continues until the temperature of indoor
heat exchanger falls.
3. Defrosting
Defrosting starts when the temperature of outdoor heat exchanger becomes too low.
The compressor stops once, the indoor/outdoor fans stop, the 4-way valve reverses, and the compressor re-starts.
This mode continues until the temperature of outdoor heat exchanger rises or the fixed time passes.
9-4. AUTO CHANGE OVER AUTO MODE OPERATION
Once desired temperature is set, unit operation is switched automatically between COOL and HEAT operation.
Mode selection
(1) Initial mode
When unit starts the operation with AUTO operation from off;
If the room temperature is higher than the set temperature, operation starts in COOL mode.
If the room temperature is equal to or lower than the set temperature, operation starts in HEAT mode.
(2) Mode change
COOL mode changes to HEAT mode when about 15 minutes have passed with the room temperature 2 degrees
below the set temperature.
HEAT mode changes to COOL mode when about 15 minutes have passed with the room temperature 2 degrees
above the set temperature.
NOTE 1
If two or more indoor units are operating in multi system, there might be a case that the indoor unit, which is operating
in (AUTO), cannot change over to the other operating mode (COOL HEAT) and becomes a state of standby.
Refer to NOTE 2 FOR MULTI SYSTEM AIR CONDITIONER.
OBH468A.qxp 07.2.19 1:53 PM Page 10
11
(3) Positioning
To confirm the standard position, the vane moves until it touches the vane stopper. Then the vane is set to the selected
angle.
Confirming of standard position is performed in the following cases:
(a) When the operation starts or finishes (including timer operation).
(b) When the test run starts.
(c) When standby mode (only during multi system operation) starts or finishes.
9-5. AUTO VANE OPERATION
1. Horizontal vane
(1) Vane motor drive
These models are equipped with a stepping motor for the horizontal vane. The rotating direction, speed, and angle of
the motor are controlled by pulse signals (approx. 12V) transmitted from indoor microprocessor.
(2) The horizontal vane angle and mode change as follows by pressing VANE CONTROL button.
(4) VANE AUTO ( ) mode
In VANE AUTO mode, the microprocessor automatically determines the vane angle to make the optimum room temper-
ature distribution.
Horizontal
position
In COOL and DRY operation
In HEAT operation
Vane angle is fixed to Horizontal position.
Vane angle is fixed to Angle 4.
(6) Dew prevention
During COOL or DRY operation with the vane angle at Angle 2 ~ 4 when the compressor cumulative operation time
exceeds 1 hour, the vane angle automatically changes to Angle 1 for dew prevention.
(5) STOP (operation OFF) and ON TIMER standby
In the following cases, the horizontal vane returns to the closed position.
(a) When OPERATE/STOP (ON/OFF) button is pressed (POWER OFF).
(b) When the operation is stopped by the emergency operation.
(c) When ON TIMER is ON standby.
NOTE 2
FOR MULTI SYSTEM AIR CONDITIONER
OUTDOOR UNIT : MXZ series
Multi system air conditioner can connect two or more indoor units with one outdoor unit.
Unit wont operate in case the total capacity of indoor units exceeds the capacity of outdoor units. Do not connect
indoor units beyond the outdoor unit capacity.
Operation indicator lamp flashes as shown in the figure below.
When you try to operate two or more indoor units with one outdoor unit simultaneously, one for the cooling and
the others for heating, the operation mode of the indoor unit that operates earlier is selected. The other indoor
units cannot operate, indicating as shown in the figure below. In this case, please set all the indoor units to the
same operation mode.
When indoor unit starts the operation while the defrosting of outdoor unit is being done, it takes a few
minutes(max. 10 minutes) to blow out the warm air.
In the heating operation, though indoor unit that does not operate may get warm or the sound of refrigerant
flowng may be heard, they are not malfunction. The reason is that the refrigerant continuously flows into it.
OPERATION INDICATOR
Not lighted
Blinking
Lighted
OBH468A.qxp 07.2.19 1:53 PM Page 11
12
To change the air
flow direction
When to use this function?
Use this function if you dont
want the air from the indoor
unit to blow directly onto your
body.
Depending on the shape of
the room, the air may blow
directly onto your body.
Press VANE CONTROL
button again to return the
vane to the previously-set
position.
Pressing and holding
VANE CONTROL
button for 2 seconds
or more causes
the horizontal vane
to reverse and
move to horizontal
position.
The air conditioner starts the
cooling or drying operation
approx. 3 minutes after the
vane has moved to the hori-
zontal position.
When VANE CONTROL
button is pressed again,
the vane returns to the
previously-set position
and the air conditioner
starts the cool or dry
operation in approx.
3 minutes.
The air conditioner starts heat-
ing operation approx. 3 minutes
after the vane has moved to the
horizontal position.
Sometimes the area
around your feet may not
warm. To warm the area
around the feet, set the
horizontal vane to
(AUTO) or the downward-
blowing position.
When VANE CONTROL
button is pressed again,
the vane returns to the
previously-set position
and the air conditioner
starts the heat operation
in approx. 3 minutes.
COOL/DRY HEAT
NOTE :
If you make the air flow not to blow directly onto your body by pressing VANE CONTROL button,
the compressor stops for 3 minutes even during the operation of the air conditioner.
The air conditioner operates with Very Low speed until the compressor turns on again.
(9) To change the air flow direction not to blow directly onto your body.
Horizontal
position
(10) ECONO COOL ( ) operation (ECONOmical operation)
When ECONO COOL button is pressed in COOL mode, set temperature is automatically set 2C higher.
Also the horizontal vane swings in various cycle.
SWING operation makes you feel cooler than set temperature. So, even though the set temperature is higher, the air
conditioner can keep comfort. As a result, energy can be saved.
ECONO COOL operation is cancelled when ECONO COOL button is pressed once again or VANE CONTROL
button is pressed or change to other operation mode.
9-6. TIMER OPERATION
1. How to set the time
(1) Check that the current time is set correctly.
NOTE : Timer operation will not work without setting the current time. Initially AM0:00 blinks at the current time display
of TIME MONITOR, so set the current time correctly with CLOCK SET button.
How to set the current time
(a) Press the CLOCK set button.
(b) Press the TIME SET buttons ( and ) to set the current time.
Each time FORWARD button ( ) is pressed, the set time increases by 1minute, and each time BACK
WARD button ( ) is pressed, the set time decreases by 1minute.
Pressing those buttons longer, the set time increases / decreases by 10 minutes.
(c) Press the CLOCK set button.
(2) Press OPERATE/STOP (ON/OFF) button to start the air conditioner.
(3) Set the time of timer.
ON timer setting
(a) Press ON TIMER button( ) during operation.
(b) Set the time of the timer using TIME SET buttons ( and ) . w
OFF timer setting
(a) Press OFF TIMER button ( ) during operation.
(b) Set the time of the timer using TIME SET buttons ( and ). w
w Each time FORWARD button ( ) is pressed, the set time increases by 10 minutes; each time BACKWARD but-
ton ( ) is pressed, the set time decreases by 10 minutes.
START
STOP
NOTE : When 2 or more indoor units are operated with multi outdoor unit, even if any indoor unit turns thermostat
off, this control doesnt work in the indoor unit.
(8) Cold air prevention in HEAT operation
The horizontal vane position is set to Upward.
(7) SWING ( ) mode
By selecting SWING mode with VANE CONTROL button, the horizontal vane swings vertically.
OBH468A.qxp 07.2.19 1:53 PM Page 12
13
EMERGENCY OPERATION switch
Operation mode COOL HEAT
Set temperature
24:
24:
Fan speed Medium Medium
Horizontal vane Auto Auto
The operation mode is indicated by the Operation
Indicator lamp on the indoor unit as following
Not lighted
Lighted
Operation Indicator lamp
EMERGENCY HEAT
EMERGENCY COOL
STOP
9-7. EMERGENCY/TEST OPERATION
In case of test run operation or emergency operation, use EMERGENCY OPERATION switch on the right side of the
indoor unit. Emergency operation is available when the remote controller is missing, has failed or the batteries of the
remote controller run down. The unit will start and OPERATION INDICATOR lamp will light.
The first 30 minutes of operation is the test run operation. This operation is for servicing. The indoor fan runs at High
speed and the system is in continuous operation (The thermostat does not work).
After 30 minutes of test run operation, the system shifts to EMERGENCY COOL / HEAT MODE with a set temperature of
24C. The fan speed shifts to Med..
In the test run or emergency operation, the horizontal vane operates in VANE AUTO ( ) mode.
Emergency operation continues until EMERGENCY OPERATION switch is pressed once or twice or the unit receives any
signal from the remote controller. In case of latter, normal operation will start.
NOTE : Do not press EMERGENCY OPERATION switch during normal operation.
2. To release the timer
To release ON timer, press ON TIMER button ( ).
To release OFF timer, press OFF TIMER button( ).
TIMER is cancelled and the display of set time disappears.
START
STOP
PROGRAM TIMER
(Example 1) The current time is 8:00 PM.
The unit turns off at 11:00 PM, and on at 6:00 AM.
OFF timer and ON timer can be used in combination. The timer of the set time that is reached first will operate first.
and display shows the order of OFF timer and ON timer operation.
(Example 2) The current time is 11:00 AM.
The unit turns on at 5:00 PM, and off at 9:00 PM.
NOTE : If the main power is turned off or a power failure occurs while ON/OFF timer is active, the timer setting
is cancelled. As these models are equipped with an auto restart function, the air conditioner starts operating with
timer cancelled when power is restored.
OBH468A.qxp 07.2.19 1:53 PM Page 13
14
10 TROUBLESHOOTING
3. Troubleshooting procedure
1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality.
To make sure, check how many times the abnormality indication is flashing on and off before starting service work.
2) Before servicing, check that the connector and terminal are connected properly.
3) If the P.C. board is supposed to be defective, check the copper foil pattern for disconnection and the components for
bursting and discoloration.
4) When troubleshooting, refer to 10-2., 10-3. and 10-4.
4. How to replace batteries
Weak batteries may cause the remote controller malfunction.
In this case, replace the batteries to operate the remote controller normally.
NOTE : 1. If RESET button is not pressed, the remote controller may not operate correctly.
2. This remote controller has a circuit to automatically reset the microcomputer when batteries are replaced.
This function is equipped to prevent the microcomputer from malfunctioning due to the voltage drop caused by
the battery replacement.
10-1. Cautions on troubleshooting
1. Before troubleshooting, check the following:
1) Check the power supply voltage.
2) Check the indoor/outdoor connecting wire for mis-wiring.
2. Take care of the following during servicing
1) Before servicing the air conditioner, be sure to turn OFF the main unit first with the remote controller, and then after
confirming the horizontal vane is closed, turn OFF the breaker and / or disconnect the power plug.
2) Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the P.C. board.
3) When removing the P.C. board, hold the edge of the board with care NOT to apply stress on the components.
4) When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.
Housing point Lead wiring
MSZ-GC22VA MSZ-GC25VA MSZ-GC35VA
RESET button
Insert the negative pole of the
batteries first. Check if the polarity
of the batteries is correct.
2 Press RESET button with tip end of ball point pen
or the like, and then use the remote controller.
1 Remove the front lid and insert batteries.
Then reattach the front lid.
1
Lock
2
If horizontal vane is not installed correctly, all of the operation indicator lamps will blink.
In this case, install the horizontal vane correctly by following the procedures 1 to 2.
NOTE : Before installation of the horizontal vane, turn OFF the power supply.
5. How to install the horizontal vane
In procedure 2 lock the
stoppers until they click
into place.
OBH468A.qxp 07.2.19 1:53 PM Page 14
15
Outline of the function
This air conditioner can memorize the abnormal condition which has occurred once.
Even though LED indication listed on the troubleshooting check table (10-4.) disappears, the memorized failure details
can be recalled.
This mode is very useful when the unit needs to be repaired for the abnormality which doesn't recur.
10-2. Failure mode recall function
1. Flow chart of failure mode recall function for the indoor/outdoor unit
Operational procedure
Yes
(Blinks)
No
(OFF)
Yes
No
Releasing the failure mode recall function
NOTE: 1.Make sure to release the failure mode recall function once it's set up, otherwise the unit cannot operate properly.
2.If the abnormal condition is not deleted from the memory, the last abnormal condition is kept memorized.
W2. Blinking pattern when the indoor unit is abnormal:
W3.Blinking pattern when the outdoor unit is abnormal:
ON
OFF
Beeps
Repeated cycle Repeated cycle
ON
OFF
No beep Beeps
Repeated cycle
2.5-second OFF
Blinking at 0.5-
second interval
2.5-second OFF 3-second ON
Blinking at 0.5-
second interval
Beeps
Repeated cycle
2.5-second OFF
Blinking at 0.5-
second interval
No beep Beeps
Repeated cycle
2.5-second OFF 3-second ON
Blinking at 0.5-
second interval
Repeated cycle
Beeps
Does upper lamp of OPERATION INDICATOR
lamp on the indoor unit blink at the interval of 0.5
seconds?
Blinks: Either indoor or outdoor unit is abnormal.
Beep is emitted at the same timing
as the blinking of upper lamp of
OPERATION INDICATOR lamp. W2
The cause of abnormality cannot be found because the abnormality doesn't recur.
Setting up the failure mode recall function
Before blinking, does upper lamp of
OPERATION INDICATOR lamp stay ON for 3
seconds?
Stays ON for 3 seconds (without beep):
The outdoor unit is abnormal.
The indoor unit is abnormal.
Check the blinking pattern, and confirm the abnormal point with the indoor unit
failure mode table(10-2.2.).
Make sure to check at least two consecutive blinking cycles. W2
Turn ON the power supply.
<Preparation of the remote controller>
1 While pressing both OPERATION SELECT
button and TOO COOL button on the remote controller at the same time, press
RESET button.
2 First, release RESET button.
And release the other two buttons after all LCD in operation display section of the
remote controller is displayed after 3 seconds.
Deleting the memorized abnormal condition
1After repairing the unit, recall the failure mode again according to
"Setting up the failure mode recall function" mentioned above.
2Press OPERATE/STOP(ON/OFF) button of the remote controller (the set temperature is displayed)
with the remote controller headed towards the indoor unit.
3Press EMERGENCY OPERATION switch so that the memorized abnormal condition is deleted.
4Release the failure mode recall function according to "Releasing the failure mode recall function"
mentioned above.
Repair the defective parts.
Release the failure mode recall function by the following procedures.
Turn OFF the power supply and turn it ON again.
Press RESET button of the remote controller.
Judgment of indoor/outdoor abnormality
Press OPERATE/STOP(ON/OFF) button of the remote controller (the set temperature
is displayed) with the remote controller headed towards the indoor unit. W1
Indoor unit is normal.
But the outdoor unit might be abnormal because there are some
abnormalities that can't be recalled with this way.
Confirm if outdoor unit is abnormal according to the detailed outdoor
unit failure mode recall function.
The outdoor unit is abnormal.
Check the blinking pattern, and confirm the abnormal point with the
outdoor unit failure mode table (Refer to outdoor unit service manual.)
Make sure to check at least two consecutive blinking cycles. W3
W1. Regardless of normal or abnormal condition,
a short beep is emitted once the signal is
received.
OBH468A.qxp 07.2.19 1:53 PM Page 15
16
2. Indoor unit failure mode table
NOTE : Blinking patterns of this mode differ from the ones of Troubleshooting check table (10-4.).
12-time flash
2.5-second OFF
Replace the indoor electronic control
P.C. board.
Indoor control system
It cannot properly read data in the
nonvolatile memory of the indoor electronic
control P.C. board.
11-time flash
2.5-second OFF
Refer to 10-6.A "Check of indoor fan
motor".
Indoor fan motor
The rotational frequency feedback signal is
not sent out for 12-seconds after indoor fan
motor is opeated.
2-time flash
2.5-second OFF
Refer to the characteristics of the main
indoor coil thermistor, the sub indoor coil
thermistor (10-7.).
Indoor coil thermistor
The indoor coil thermistor short or open
circuit is detected every 8 seconds during
operation.
3-time flash
2.5-second OFF
Refer to 10-6.D "How to check mis-wiring
and serial signal error".
Serial signal
The serial signal from outdoor unit is
not received for 6 minutes.
1-time flash
every 0.5-second
Refer to the characteristics of the room
temperature thermistor (10-7.).
Room temperature
thermistor
The room temperature thermistor short
or open circuit is detected every 8 seconds
during operation.
Not lighted Normal
Upper lamp of OPERATION
INDICATOR lamp
Correspondence
Abnormal point
(Failure mode)
Condition
OBH468A.qxp 07.2.19 1:53 PM Page 16
17
Start
Indoor unit
operates.
Outdoor unit
doesn't
operate.
Indoor unit
doesn't receive
the signal from
remote controller.
OPERATION INDICATOR
lamp on the indoor unit is
flashing on and off.
Outdoor unit
operates only
in Test Run
operation.
w
Outdoor unit
doesn't
operate
even in
Test Run
operation.
w
Indoor unit
operates, when
EMERGENCY
OPERATION
switch is pressed.
Indoor unit
doesn't operate,
when
EMERGENCY
OPERATION
switch is pressed.
Check room
temperature
thermistor.
Refer to 10-7.
"Test point
diagram and
voltage".
Refer to
"How to check
inverter/
compressor".
Refer to 10-6.B
"Check of
remote controller
and indoor
electronic control
P.C. board".
1. Check indoor / outdoor
connecting wire.
(Check if the power
is supplied to the
indoor unit.)
2. Refer to 10-6.C
"Check of indoor
P.C. board and indoor
fan motor".
Unit doesn't
operate
normal
operation in
COOL or
HEAT mode.
Refer to
"Check of
R.V. coil".
Refer to outdoor unit service manual.
Indoor unit operates.
Outdoor unit doesn't
operate normally.
If blinking of OPERATION
INDICATOR lamp cannot be
checked, it can be checked with
failure mode recall function.
w
"Test Run operation" means the
operation within 30 minutes after
EMERGENCY OPERATION switch
is pressed.
Upper lamp
Flash on and off
at 0.5-second
intervals
Cause:
Indoor/
Outdoor unit
Mis-wiring
or trouble
of serial signal
Upper lamp
2-time flash
Cause:
Indoor unit
Trouble of
room temp-
erature/
indoor coil
thermistor
Upper lamp
3-time flash
Cause:
Indoor unit
Trouble of
indoor fan
motor
Upper lamp
5-time flash
Cause:
Outdoor unit
Outdoor
power
system
abnormality
Upper lamp
6-time flash
Cause:
Outdoor unit
Trouble of
thermistor
in outdoor
unit
Upper lamp
7-time flash
Cause:
Outdoor unit
Trouble of
outdoor
control
system
Refer to 10-6.
D "How to
check of
mis-wiring
and serial
signal error".
All lamps
Flash on and off
at 0.5-second
intervals
Cause:
Indoor unit
The horizontal
vane is not
installed
correctly.
Refer to 10-6.
E "Check of
installation of
the horizontal
vane".
Check room
temperature
thermistor
and indoor
coil thermis-
tor.
Refer to 10-7.
"Test point
diagram and
voltage".
Refer to 10-6.
A "Check of
indoor fan
motor".
Refer to
"How to check
inverter/
compressor".
Refer to
"Check of
outdoor
thermistors".
Replace the
inverter P.C.
board or
the outdoor
electronic
control P.C.
board.
Upper lamp
14-time flash
Cause:
Outdoor unit
Other
abnormality
Check
"Flow chart of
the detailed
outdoor unit
failure mode
recall function."
Upper lamp
4-time flash
Cause:
Indoor unit
Trouble of
indoor unit
control
system
Replace the
indoor
electronic
control
P.C. board.
10-3. Instruction of troubleshooting
OBH468A.qxp 07.2.19 1:53 PM Page 17
18
No.
1
2
5
6
Symptom Operation indicator lamp Condition Correspondence
Upper lamp flashes.
0.5-second ON
0.5-second OFF
Mis-Wiring
or serial
signal
Outdoor
power
system
Outdoor
thermistors
Outdoor
control
system
Indoor coil
thermistor
The serial signal from the outdoor unit is not
received for 6 minutes.
It consecutively occurs 3 times that the
compressor stops for overcurrent protection or
start-up failure protection within 1 minute after
start-up.
The outdoor thermistors short or open circuit
during the compressor operation.
It cannot properly read data in the nonvolatile
memory of the inverter P.C. board or the
outdoor electronic control P.C. board.
Refer to "Check of outdoor
thermistor".
Refer to outdoor unit service
manual.
Refer to "How to check of
inverter/compressor".
Refer to outdoor unit service
manual.
Check the stop valve.
Replace the inverter P.C.
board or the outdoor
electronic control P.C. board.
Refer to outdoor unit service
manual.
Refer to 10-6.D "How to check
mis-wiring and serial signal
error".
3
Indoor fan
motor
7
Abnormal
point
Room
temperature
thermistor
Upper lamp flashes.
2-time flash
2.5-second OFF
The indoor coil or the room temperature
thermistor is short or open circuit.
Refer to 10-7.the
characteristics of indoor coil
thermistor, and the room
temperature thermistor.
Upper lamp flashes.
3-time flash
2.5-second OFF
The rotational frequency feedback signal is
not emitted during the indoor fan operation.
Refer to 10-6.A "Check of
indoor fan motor".
Indoor unit
and outdoor
unit do not
operate.
Upper lamp flashes.
5-time flash

2.5-second OFF
Upper lamp flashes.
6-time flash
2.5-second OFF
Other
abnormality
An abnormality other than above mentioned is
detected.
Check the stop valve.
Confirm the abnormality in
detail using the failure mode
recall function for outdoor
unit.
8
4
Upper lamp flashes.
4-time flash

2.5-second OFF
Indoor
control
system
It cannot properly read data in the nonvolatile
memory of the indoor electronic control P.C.
board.
Replace the indoor electronic
control P.C. board.
Outdoor
control
system
It cannot properly read data in the nonvolatile
memory of the inverter P.C. board or the
outdoor electronic control P.C. board.
Check the blinking pattern of
the LED on the inverter P.C.
board or the outdoor
electronic
control P.C. board.
9
Outdoor unit
does not
operate.
Upper lamp lights up

Upper lamp flashes.
7-time flash

2.5-second OFF
Upper lamp flashes.
14-time flash
2.5-second OFF
10-4. Troubleshooting check table
Not lighted
Blinking
OPERATION INDICATOR
Lighted
Before taking measures, make sure that the symptom reappears for accurate troubleshooting.
When the indoor unit has started operation and the following detection method has detected an abnormality (the first
detection after the power ON), the indoor electronic control P.C. board turns OFF the indoor fan motor with
OPERATION INDICATOR lamp flashing.
OBH468A.qxp 07.2.19 1:53 PM Page 18
19
10-5. Trouble criterion of main parts
MSZ-GC22VA MSZ-GC25VA MSZ-GC35VA
Measure the voltage power ON.
Figure
Measure the resistance between the terminals with a tester.
(Part temperature 10C ~ 30C)
BLK
BLK
RED
BLK BLK
ROTOR
B
L
K
R
E
D
W
H
T
G
R
Y
Y
L
W
B
R
N
MAIN
AUX.
FUSE
M
o
t
o
r

p
a
r
t
S
e
n
s
o
r

p
a
r
t
Measure the resistance between the terminals with a tester.
(Part temperature 10C ~ 30C)
BRN YLW
BRN GRY
Normal
4.5 ~ 5.5V
(When fan revolved one time)
0V5V0V
(Approx.)
Color of lead wire
Part name Check method and criterion
Indoor fan motor (MF)
INNER FUSE
BA : 135i3: CUT OFF
CA : 140i2: CUT OFF
Measure the resistance with a tester.
Refer to 10-7."Test point diagram and voltage",
"2.Indoor electronic control P.C. board", the chart of thermistor.
Room temperature
thermistor (RT11)
Indoor coil thermistor
(RT12, RT13)
Vane motor (MV)
Normal
RED-BLK 235 " ~ 255 "
Color of the lead wire
WHT BLK
BLK RED
Normal
RC4V18-BA
273 " ~ 296 "
295 " ~ 320 "
Color of lead wire
RC4V18-CA
308 " ~ 334 "
295 " ~ 320 "
OPERATION INDICATOR
OPERATION INDICATOR
No.
1
Symptom Operation indicator lamp Condition Correspondence
Abnormal
point
0.5-second ON
0.5-second OFF
The electricity is not conducted to the interlock
switch (Fan) of the horizontal vane.
Refer to 10-6.E "Check of
installation of the horizontal
vane".
Indoor unit
and outdoor
unit do not
operate.
Attachment
of the
horizontal
vane
All lamps flash at the same time.
No. Symptom Operation indicator lamp Condition Correspondence
Abnormal
point
1
MXZ type
Operation
mode
setting
Outdoor unit
operates but
indoor unit
does not
operate.
The operation mode of the each indoor
unit is differently set to COOL(includes DRY)
and HEAT at the same time, the operation
mode of the indoor unit that has operated at
first has the priority.
Unify the operation mode.
Refer to outdoor unit service
manual.
2.5-second OFF
Upper lamp lights and lower lamp flashes.
OBH468A.qxp 07.2.19 1:53 PM Page 19
20
Check of remote controller and indoor electronic control P.C. board B
Indoor unit operates by pressing EMERGENCY OPERATION switch, but does not operate with the remote controller.
wCheck if the remote controller is exclusive for this air conditioner.
Yes
Replace the batteries. (Refer to 10-1.4.)
Is noise heard from radio?
Are there any fluorescent lights of
inverter or rapid-start type within
the range of 1m?
Replace the indoor electronic
control P.C. board.
(including the receiver)
Replace the remote controller.
G Reinstall the unit away from lights.
G Attach a filter on receiving part.
Press OPERATE/STOP(ON/OFF) button on the remote controller.
Is LCD display on the the remote
controller visible?
Remove the batteries, then set them back
and press RESET button. (Refer to 10-
1.4.) Check if the unit operates with the
remote controller.
Yes
Does the unit operate with the
remote controller?
Yes
OK
No
(not clear)
Yes
No
No
No
Check of indoor fan motor A
When OPERATION INDICATOR lamp flashes 3-time. Indoor fan does not operate.
10-6. Troubleshooting flow
CN211
Indoor power P.C.board
Fuse (F11)
Indoor terminal
P.C.board
Varistor
(NR11)
CN121
Is the resistance 0 (short circuit) or (open circuit)?
Yes ( 0 or )
No Yes No
Turn OFF the power supply.
Check connector CN211 visually.
Disconnect the lead wires from connector CN211 on indoor power P.C. board.
Measure the resistance between lead wires No.1 and No.4 and then No.4 and No.7.
Turn ON the power supply. Rotate indoor fan slowly for 1 revo-
lution or over with a screwdriver etc. from air outlet, and mea-
sure the voltage No.2(+) and No.1(-) on CN121.
No
(others)
Replace the indoor power / terminal P.C. board
and the indoor electronic control P.C. board.
Does the voltage repeat 0V DC and 5V DC?
Yes
No
Are lead wires connected? Reconnect the lead wires.
Resolder it.
Replace the indoor fan motor.
Are soldered points of the
connector correctly soldered to
indoor power P.C. board?
Yes
Turn ON a radio to AM and press
OPERATE/STOP(ON/OFF) button on the remote controller.
OBH468A.qxp 07.2.19 1:53 PM Page 20
21
The unit does not operate with the remote controller.
Also, OPERATION INDICATOR lamp does not light up by pressing EMERGENCY OPERATION switch.
Check of indoor P.C. board and indoor fan motor C
Yes
No
w. Please replace the fuse after removing
the indoor terminal P.C. board from the electrical box.
Yes
No
Does the unit operate with the remote controller?
Does OPERATION INDICATOR lamp light up by
pressing EMERGENCY OPERATION switch?
Turn OFF the power supply.
Remove indoor fan motor connector CN211 from indoor
power P.C. board and vane motor connector CN151
from the indoor electronic control P.C. board and turn
ON the power supply.
Measure the resistance of the vane motor coil.
Refer to 10-5.
Measure the resistance
Refer to 10-5 of indoor fan motor.
Short circuit:
Replace the indoor fan motor.
Short circuit:
Replace the vane motor and the indoor
electronic control P.C. board.
Turn OFF the power supply.
Check both parts side and pattern
side of the indoor terminal P.C.
board visually.
Replace the varistor(NR11) and fuse(F11). w
Are the varistor (NR11) burnt
and the fuse (F11) blown?
Be sure to check both the fuse
and the varistor in any case.
No
Yes
No
Is the fuse (F11) blown only?
Yes
No
Is the resistance normal?
Is the approx. 5VDC between 5V (+)
and JPG(GND) () of the indoor
electronic control P.C.board? Is there
approx. 9V to 13VDC between 12V (+)
and JPG (GND) () of the indoor
electronic control P.C. board.
Measure the resistance of
indoor fan motor.
Refer to 10-5.
Replace the fuse (F11). w
Replace the fuse (F11) and the indoor fan motor. w
Is the resistance
approx. 4'?
Measure the resistance of cement
resistor R111 on the indoor power
P.C. board.
Replace the indoor fan motor.
Yes
Connect the connector or repair
disconnection.
Yes
No
Are connector CN10A on
the indoor electronic control
P.C. board or lead wires
disconnected?
No
Replace the indoor power / terminal P.C. board.
Replace the indoor power / terminal P.C. board
and the indoor fan motor.
Yes
JPG (GND)
12VDC
5VDC
CN10A
CN211
Indoor power P.C.board
Indoor electronic
control P.C.board
Fuse (F11)
Indoor terminal
P.C.board
Varistor
(NR11)
R111
OBH468A.qxp 07.2.19 1:53 PM Page 21
22
How to check mis-wiring and serial signal error D
Is there rated voltage in
the power supply?
Is there any mis-wiring,
poor contact, or wire
disconnection of the
indoor/outdoor
connecting wire?
W1. Mis-wiring may damage indoor P.C. board during the
operation.
Be sure to confirm the wiring is correct before the
operation starts.
W3. Be sure to check this within 3 minutes after turning ON.
After 3 minutes, LED blinks 6 times. Even when
the inverter P.C.board or the outdoor electronic control
P.C.board is normal, LED blinks 6 times after 3 minutes.
(Except for outdoor unit of multi system type)
(Lighted or
not lighted)
No
Yes
No
Yes
Yes
No
Yes
No Yes
W2 Be careful to the residual
voltage of smoothing capacitor.
No
No
Yes
No
Yes
Yes
Turn OFF the power supply.
Turn ON the power supply.
Is there rated voltage between
outdoor terminal block S1 and
S2?
Does the upper lamp of OPERATION
INDICATOR lamp light up?
<Confirmation of the power to the indoor unit>
Press EMERGENCY OPERATION switch once.
Check the power
supply.
A
Turn OFF the power supply.
Check once more if the indoor/outdoor
connecting wire is not mis-wiring.
Short-circuit outdoor terminal block S2 and
S3.
W1
B
Turn ON the power supply.
Check the wiring.
Correct them.
Turn OFF the power supply.
Remove the short-circuit between
outdoor terminal block S2 and S3.
Turn ON the power supply.
Is there amplitude of 10 to 20V DC
between indoor terminal block S2
and S3? <Confirmation of serial
signal>
Is there rated voltage between
indoor terminal block S1 and S2?
<Confirmation of power voltage>
No
No No Yes
Yes
Yes
Replace the inverter P.C. board or
the outdoor electronic control P.C.board.
W2
Is there any error of the
indoor/outdoor connecting wire,
such as the damage of the wire,
intermediate connection, poor
contact to the terminal block?
No
Replace the
indoor/outdoor
connecting wire.
Is serial signal
error indicated
6 minutes later?
Yes
No
Turn OFF inverter-controlled lighting
equipment.
Turn OFF the power supply and then
turn ON again.
Press EMERGENCY OPERATION
switch.
B
Reinstall
either the
unit or the
light each
other away.
Attach a filter
on remote
control
receiving
section of
the indoor
unit.
A
Is serial signal error indicated 6 minutes later?
Is there 2V DC or less between CN10A3(+)
and JPG(GND)() on the indoor electronic
control P.C. board?
Is there 2V DC or less between
CN10A4(+) and JPG(GND)()
on the indoor electronic control
P.C. board?
Be sure to release the failure-mode recall function after checking.
Is there 2V DC or less between
CN10A4(+) and JPG(GND)()
on the indoor electronic control
P.C. board?
Does the LED on the inverter P.C. board
or the outdoor electronic control P.C. board
repeat "3.6-second-OFF and 0.8-second-ON
quick blinking"? W3
Replace the indoor power /
terminal P.C. board.
Replace the indoor
electronic control P.C. board.
When unit cannot operate neither by the remote controller nor by EMERGENCY OPERATION switch.
Indoor unit does not operate.
When OPERATION INDICATOR lamp flashes ON and OFF every 0.5-seconds.
Outdoor unit does not operate.
OBH468A.qxp 07.2.19 1:53 PM Page 22
23
Check of installation of the horizontal vane E
Replace the
indoor electronic
control P.C. board.
Replace the
interlock switch(Fan).
Is the stopper of the horizontal vane
locked to the indoor unit correctly?
Yes
No
Is there resistance 0 "?
Relock the stopper of the
horizontal vane to the indoor unit.
(Refer to 10-1.5.)
Yes
Are all lamps flashing?
Yes
No()
No
OK
Turn ON the
power supply.
To check the continuity of the interlock switch
(Fan), measure the resistance of connector 1 - 2
connected to CN1R1 on the indoor
electronic control P.C. board.
Turn OFF the
power supply.
Turn OFF the
power supply.
When All lamps flash ON and OFF every 0.5-second.
Indoor unit and outdoor unit do not operate.
OBH468A.qxp 07.2.19 1:53 PM Page 23
24
Electromagnetic noise enters into TV sets or radios F
Replace or repair the antenna.
Replace or repair the coaxial cable.
No
No
No
Yes
Yes
No
No
Yes
Yes
Yes
Is the distance between the
antennas and the indoor
unit within 3m, or is the
distance between the
antennas and the outdoor
unit within 3m?
Is the distance between the
TV sets or radios and the
indoor unit within 1m, or is
the distance between the TV
sets or radios and the
outdoor unit within 3m?
Are the antennas damaged?
Is the coaxial cable damaged?
Is there any poor contact in
the antenna wiring?
Is the indoor/outdoor
connecting wire of the air
conditioner and the wiring of
the antennas close?
Even if all of the above conditions are fulfilled, the electromagnetic noise may enter, depending on
the electric field strength or the installation condition (combination of specific conditions such as
antennas or wiring).
Check the followings before asking for service.
1.Devices affected by the electromagnetic noise
TV sets, radios (FM/AM broadcast, shortwave)
2.Channel, frequency, broadcast station affected by the electromagnetic noise
3.Channel, frequency, broadcast station unaffected by the electromagnetic noise
4.Layout of ;
indoor/outdoor unit of the air conditioner, indoor/outdoor wiring, grounding wire, antennas, wiring
from antennas, receiver
5.Electric field intensity of the broadcast station affected by the electromagnetic noise
6.Presence or absence of amplifier such as booster
7.Operation condition of air conditioner when the electromagnetic noise enters in.
1)Turn OFF the power supply once, and then turn ON the power supply. In this situation, check for
the electromagnetic noise.
2)Within 3 minutes after turning ON the power supply, press OPERATE/STOP (ON/OFF) button
on the remote controller for power ON, and check for the electromagnetic noise.
3)After a short time (3 minutes later after turning ON), the outdoor unit starts running. During
operation, check for the electromagnetic noise.
4)Press OPERATE/STOP (ON/OFF) button on the remote controller for power OFF, when the
outdoor unit stops but the indoor/outdoor communication still runs on. In this situation, check for
the electromagnetic noise.
After checking the above, consult the service representative.
Is the unit earthed? Earth the unit.
Extend the distance between
the antennas and the indoor
unit, and/or the antennas and
the outdoor unit.
Extend the distance between
the TV sets and/or radios and
the indoor unit, or the TV sets
or radios and the outdoor unit.
Extend the distance between
the indoor/outdoor connecting
wire of the air conditioner and
the wiring of the antennas.
OBH468A.qxp 07.2.19 1:53 PM Page 24
25
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12, RT13)
Temperature (:)
R
e
s
i
s
t
a
n
c
e

(
k
"
)
MSZ-GC22VA MSZ-GC25VA MSZ-GC35VA
1. Indoor power P.C. board, Indoor terminal P.C. board
10-7. Test point diagram and voltage
Timer short mode
point JPG JPS
(Refer to 8-1.)
Room temperature thermistor RT11 (CN111)
Indoor coil thermistor RT12, RT13(CN112)
Vane motor (CN151)
Connector to
Indoor power P.C. board
(CN10A)
12V DC
5V DC
Release of Auto restart function
Solder the Jumper wire to JR07
(Refer to 8-3.)
Emergency operation
switch (E.O.SW) (SW1)
2. Indoor electronic control P.C. board
Indoor terminal P.C. board Indoor power P.C. board
w Please replace the fuse after removing the indoor terminal P.C. board from the electrical box.
Fuse (F11)(w)
Varistor (NR11)
Terminal
block
Connector to indoor electronic
control P.C. board (CN20A)
5VDC 12VDC GND
Indoor fan motor
(CN211)
230V AC
R111
}
CN121
GND
Interlock switch (FAN)(CN1R1)
OBH468A.qxp 07.2.19 1:54 PM Page 25
26
11
DISASSEMBLY INSTRUCTIONS
(1) Slide the sleeve and check if there is a locking lever or not. (2) The terminal with this connector has the
locking mechanism.
1Slide the sleeve.
2Pull the terminal while
pushing the locking
lever.
1Hold the sleeve, and
pull out the terminal
slowly.
The terminal which has the locking mechanism can be detached as shown below.
There are two types ( Refer to (1) and (2)) of the terminal with locking mechanism.
The terminal without locking mechanism can be detached by pulling it out.
Check the shape of the terminal before detaching.
<"Terminal with locking mechanism" Detaching points>
Connector
Sleeve
Locking lever
MSZ-GC22VA MSZ-GC25VA MSZ-GC35VA
OPERATING PROCEDURE PHOTOS
Photo 1
1. Removing the panel
(1) Remove the screw caps of the panel. Remove the screws.
(2) Hold the lower ends part of the panel and pull it slightly
toward you, and then remove the panel by pushing it
upward.
Screws of the panel
OBH468A.qxp 07.2.19 1:54 PM Page 26
27
3. Remove the indoor power P.C. board, the indoor ter-
minal P.C. board, and the electrical box
(1) Turn the breaker OFF.
(2) Remove the panel (Refer to 1) and the corner box.
(3) Remove the screw of V.A. clamp, and then the indoor/out-
door connecting wire.
(4) Remove the earth wire connected to the indoor heat
exchanger from the electrical box.
(5) Unhook first the lower, then the upper catches of the elec-
trical box, and pull out the electrical box.
(6) Remove the screw of the electrical cover and remove the
electrical cover.
(7) Disconnect all the connectors on the indoor power P.C.
board and unhook all lead wires.
(8) Remove the screw of terminal block on the indoor terminal
P.C. board.
(9) Remove the indoor power P.C. board and the indoor termi-
nal P.C. board.
OPERATING PROCEDURE PHOTOS
Lower catch
Indoor terminal
P.C. board
Photo 3
2. Removing the indoor electronic control P.C. board
and the room temperature thermistor
(1) Turn the breaker OFF.
(2) Remove the panel (Refer to 1) and the corner box.
(3) Open the indoor electronic control P.C. board holder (to
right side), and disconnect connectors of the indoor coil
thermistor (CN112), vane motor (CN151), interlock switch
(CN1R1) and connector (CN10A) to the indoor power P.C.
board on the indoor electronic control P.C. board.
(4) Unhook the catches of the indoor electronic control P.C.
board holder from the nozzle and the electrical box (right
side).
(5) Remove the room temperature thermistor from the hook of
the indoor electronic control P.C. board holder.
(6) Open the back side of the indoor electronic control P.C.
board holder, and remove the indoor electronic control P.C.
board.
(7) Remove the room temperature thermistor from the indoor
electronic control P.C. board.
Photo 2
V.A. clamp
Indoor electronic control
P.C. board holder
Screw of the
electrical cover
Terminal block
Indoor power
P.C. board
Catch of indoor electronic
control P.C. board holder
Catch of indoor electronic
control P.C. board holder
Upper catch
Electrical box
OBH468A.qxp 07.2.19 1:54 PM Page 27
OPERATING PROCEDURE PHOTOS
4. Removing the vane motor
(1) Turn the breaker OFF.
(2) Remove the panel (Refer to 1) and the corner box.
(3) Remove the indoor electronic control P.C. board
holder(Refer to 2).
(4) Remove the screws of vane motor and remove the vane
motor.
(5) Disconnect the connector from vane motor.
5. Removing the indoor fan motor, the indoor coil ther-
mistor, and the line flow fan
(1) Remove the panel (Refer to 1) and the corner box.
(2) Remove the indoor electronic control P.C. board holder (Refer to
2) and the electrical box (Refer to 3) .
(3) Remove the drain hose from the nozzle assembly, and
remove the nozzle assembly.
(4) Loosen the screw fixing the line flow fan.
(5) Remove the screws fixing the motor bed. Lift the right side
of motor bed a little, and pull right to remove the fan motor
together with motor band/bed.
(6) Remove the indoor coil thermistor from the heat exchanger
(w) Install the indoor coil thermistor in its former position when
assembling it.(Refer to Photo 7)
(7) Remove the screws fixing the left side of the heat exchang-
er.
(8) Lift the left side of the heat exchanger, and pull out the line
flow fan to the lower-left.
Photo 6
Photo 4
Screws of the vane motor
Screws of the motor bed
Photo 5
Screws of the line flow fan
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
C Copyright 2006 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD
Distributed in Feb. 2007. No. OBH468 REVISED EDITION-A 6
Distributed in Dec. 2006. No. OBH468 6
Made in Japan
New publication, effective Feb. 2007
Specifications subject to change without notice.
Photo 7
Indoor coil
thermistor(sub)
RT13
Indoor coil
thermistor(main)
RT12
OBH468A.qxp 07.2.19 1:54 PM Page 28
Sp-3
MANUAL DE INSTRUCCIONES
RESET
CLOCK
Asegrese de que la polaridad de las pilas es la correcta.
No utilice pilas de manganeso. El controlador remoto podra funcionar
inadecuadamente.
No utilice pilas recargables.
Sustituya todas las pilas por otras nuevas de la misma clase.
Las pilas pueden durar 1 ao aproximadamente. Ahora bien, las pilas
caducadas pueden durar menos.
Antes de la puesta en funcionamiento: inserte el enchufe de alimentacin en la toma de corriente y/o encienda el disyuntor.
Pulse RESET y CLOCK ligeramente con un
palillo.
Si nosepulsael botndereinicializacin(RESET), el
controlador remoto no funcionar correctamente.
RESET
CLOCK
Seccin de pantalla
Luz de indicacin del
funcionamiento
Seccin de recepcin
del controlador remoto
Interruptor de accionamiento
de emergencia Pgina 4
Entrada de aire
(lado posterior y lateral)
Tubera
Manguera de drenaje
Salida de aire
Salida de drenaje
Soporte del controla-
dor remoto
Seccin de transmi-
sin de seales
Distancia de la seal:
Aprox. 6 m
Cuando se recibe la
seal, la unidad interior
emite un sonido.
Seccin de pan-
talla de acciona-
miento
Botn ON/OFF
(activacin/des-
activacin de
funcionamiento)
Botones de tempera-
tura Pgina 4
Botn de selec-
cin del modo de
funcionamiento
Pgina 4
Botn de
desconexin
automtica
(ECONOCOOL)
Pgina 5
Botn de control
de velocidad del
ventilador
Pginas 5
Botn de desactivacin
del temporizador Pgina 5
Botn de activacin del
temporizador Pgina 5
Botn de
control de las
lamas
Pgina 5
Botones de ajuste del
TIMER (TEMPORIZA-
DOR) Pgina 3, 5
Aumentar tiempo
Reducir tiempo
Botn de ajuste del reloj
(CLOCK) Pgina 3
Botn de reinicializacin
(RESET) Pgina 3
Tapa
Deslcela hacia abajo
para abrir
Instale el soporte del con-
trolador remoto en un lugar
en el que la unidad interior
pueda recibir la seal.
Use nicamente el controlador remoto suministrado con la unidad.
No use otro controlador remoto.
Defector horizontal
Defector
vertical
Salida de
aire
Ventilador
Filtro de aire
(fltro de aire
de taninos)
Entrada de aire
Intercambiador de calor
Panel frontal
Filtro de limpieza del aire
Protector del
ventilador
Unidad exterior
Instalacin de las pilas del controlador
remoto
Ajuste de la hora actual
NOMBRE DE LAS PARTES
PREPARACIN ANTES DE LA PUESTA EN MARCHA
1.
Retire la tapa frontal
2. Introduzca pilas
alcalinas tipo AAA
3. Coloque la tapa
frontal
1. Pulse RESET
2. Pulse CLOCK
4. Pulse otra vez
CLOCK
3. Pulse los botones de TIME
para ajustar la hora
Cada pulsacin aumenta/dis-
minuye la hora en 1 minuto (10
minutos cuando la pulsacin
es prolongada)
Unidadinterior Controlador remoto
El aspecto de la unidad exterior puede variar en algunos modelos.
Sp-4
ModoAUTO (Cambioautomtico)
Launidadseleccionael mododefuncionamientodeacuerdoconladiferen-
cia que haya entre la temperatura ambiente y la temperatura establecida.
Durante el modo AUTO, la unidad cambia el modo (REFRGERACN
CALEFACCN) cuando la temperatura ambiente difere en 2C de la tem-
peratura establecida durante ms de 15minutos.
Not a:
Durante el funcionamiento multisistema, puede suceder que la unidad no
pueda cambiar entre los modos REFRIGERACIN yCALEFACCIN. En
tal caso, la unidad interior se coloca en el modo de espera.
ModoREFRI GERACI N
Disfrute de aire fro a la temperatura que desee.
No active el modo de REFRIGERACIN cuando la temperatura exterior
sea baja (inferior a -10C). El agua condensada en la unidad puede gotear
y humedecer o daar el mobiliario, etc.
MododeDESHUMI DI FI CACI N
Deshumedezca su habitacin. Puede refrigerarla ligeramente.
La temperatura no se puede ajustar mientras el aparato est en el modo
de DESHUMIDIFICACIN.
MododeCALEFACCI N
Disfrute de aire clido a la temperatura que desee.
Luz de indicacin de funcionamiento
Luz deindicacindefuncionamiento
La luz de indicacin de funcionamiento muestra el estado de funcionamiento
de la unidad.
Indicacin Estado de funcionamiento Temperatura ambiente
La unidad est en funcionamiento
para alcanzar la temperatura fjada
Aproximadamente 2C o
ms de diferencia con la
temperatura fijada
La temperatura ambienteseacerca
a la temperatura fjada
Aproximadamente de 1 a
2C de diferencia con la
temperatura fijada
Modo en espera (slo durante el
funcionamiento multisistema)

Luz encendida Luz parpadeante Luz apagada
Funcionamiento de emergencia
Si nosepuedeutilizar el controlador remoto...
Se puede activar el funcionamiento de emergencia pulsando el interruptor de
accionamiento de emergencia en la unidad interior.
Cada vez que se pulsa el interruptor de emergencia, el fun-
cionamiento cambia en el orden siguiente:
1
Pulse para que se ponga en funcionamiento.
2
Pulse para seleccionar el modo de funciona-
miento. El modo cambia con cada pulsacin de la
manera siguiente:
3
Pulse o para ajustar la temperatura.
Cada pulsacin eleva o disminuye la temperatura en
1C.
Pulse para apagarlo.
Cuando vuelva a encenderlo, se activar la misma configuracin se-
leccionada si pulsa .
Funcin de reinicio automtico
En caso de que se produzca un corte en el suministro elctrico o se apague la
unidadmientras estfuncionando, lafuncindereinicioautomticoseactivar
automticamente en el mismo modo seleccionado con el controlador remoto
antes de que se interrumpiese el funcionamiento. Cuando est confgurado el
temporizador, los ajustes se anulan y la unidad empieza a funcionar al volver
a encenderla.
Si no desea utilizar esta funcin, pngase en contacto con el servicio
tcnico ya que tendr que modicar Ios ajustes de Ia unidad.
Funcionamiento multisistema
Dos oms unidades interiores puedenfuncionarconunaunidadexterior. Si seac-
tivanvarias unidades interiores al mismotiempo, las operaciones derefrigeracin
ycalefaccinnopuedenrealizarsesimultneamente. Cuandoestseleccionada
la REFRIGERACIN en una unidad y CALEFACCIN en otra o viceversa, la
unidad que se haya activado despus se pone en modo de espera.
SELECCIN DE MODOS DE FUNCIONAMIENTO
Temperatura fjada: 24C
Velocidad del ventilador: media
Defector horizontal: auto
(AUTO)
(REFRIGERACIN)
(DESHUMIDIFICACIN)
(CALEFACCIN)
REFRIGERACIN
de emergencia
CALEFACCIN de
emergencia
Parada
Not a:
Los primeros 30 minutos de funcionamiento son de prueba.
El control de temperatura no funciona y la velocidad del ven-
tilador est fjada en Alta.
Sp-5
MANUAL DE INSTRUCCIONES
VELOCIDAD DEL VENTILADOR Y
AJUSTE DE LA DIRECCIN DEL AIRE
FUNCIONAMIENTO DE LA DESCO-
NEXIN AUTOMTICA (ECONO COOL)
Pulse para seleccionar la velocidad del venti-
lador. La velocidad del ventilador cambia con cada
pulsacin en el orden siguiente:
Al configurar la unidadinterior enAUTO, se escuchan dos pitidos cor-
tos.
Pulse para seleccionar la direccin del aire. La
direccin del aire cambia con cada pulsacin en el
orden siguiente:
Al configurar la unidadinterior enAUTO, se escuchan dos pitidos cor-
tos.
Mantngalo pulsado durante 2 segundos o ms para configurar la di-
reccin en posicin horizontal.
Pulse una vez para cancelar la posicin horizontal.
Cuandoladireccindel aireseajustaenposicinhorizontal, ocuando
se cancela la posicin horizontal, deja de funcionar 3 minutos aproxi-
madamente.
Direccin del flujo de aire
(AUTO).........El defector se ajusta en la direccin con mayor rendimiento
deladireccindel aire. REFRIGERACIN/DESHUMIDIFICA-
CIN:posicin horizontal. CALEFACCIN:posicin (4).
(Manual).......Para unmejor rendimiento del acondicionador deaire, selec-
cione la posicin superior para REFRIGERACIN/DESHU-
MIDIFICACIN, y la posicin inferior para CALEFACCIN.
Durante la REFRGERACN/CALEFACCN, el defector
se coloca automticamente enla posicin(1) despus de 30
minutos a 1 hora para evitar que el agua gotee.
(Oscilacin) ..El deflector asciende y desciende de forma intermitente.
Posicin horizontal
Posicin recomendada durante REFRIGERACIN/CALE-
FACCIN. El aire no se dirige directamente a los ocupantes
de la habitacin, proporcionando una distribucin del fujo de
aire muy agradable.
Para cambiar Ia direccin deI ujo de aire
Desplace el defector vertical manual antes de que empiece a funcionar el
acondicionador.
Pulse durante el modo REFRIGERACIN
pgina 4 para iniciar el funcionamiento de desco-
nexin automtica (ECONO COOL).
La unidad realiza la operacin de oscilacin verticalmente en varios ci-
clos de acuerdo con la temperatura de la unidad. La temperatura fijada
sube automticamente 2C.
Pulse otra vez para cancelar la operacin ECO-
NO COOL.
Si pulsa se cancela tambin la operacin ECONO COOL.
En qu c onsi st e l a f unc i n de
desc onex i n aut omt i c a (ECONO COOL) ?
Si la direccin del aire cambia cada cierto tiempo (vaivn del aire), el ambiente
se refresca ms que si la direccin se mantiene siempre fja. As pues, aunque
la temperatura establecida aumente automticamente en 2C, puede utilizar
esta funcin cuando el aparato est en modo de refrigeracin y as sentirse
cmodo. Adems, podr ahorrar energa.
FUNCIONAMIENTO DEL TEMPORI-
ZADOR (ACTIVACIN/DESACTIVA-
CIN DEL TEMPORIZADOR)
1
Pulse o durante el funcionamiento para
ajustar el temporizador.
(ACTIVACIN del temporizador):
La unidad se encender a la
hora establecida.
(DESACTIVACIN del temporizador):
La unidad se apagar a la hora
establecida.
* o parpadea.
* Asegrese de que la hora actual es la correcta. Pgina 3
2
Pulse (Aumentar) y (Disminuir) para ajustar
la hora del temporizador.
Con cada pulsacin la hora establecida aumenta o disminuye en 10
minutos.
3
Pulse o de nuevo para cancelar el tempo-
rizador.
Not a:
Los botones de ACTIVACIN yDESACTIVACIN del temporizador pueden
usarse simultneamente. La marca muestra el orden en el que se acti-
varn los temporizadores.
Si se produce un corte en el suministro elctrico mientras est confgurado
el temporizador en ACTIVACIN/DESACTIVACIN, consulte la pgina 4
Funcin de reinicio automtico.
(AUTO) (Baja) (Media) (Alta) (Muy alta)
(AUTO) (1) (2) (3) (4) (OSCILACIN)
Sp-6
Panel frontal
I nst r uc c i ones:
1. Suba el panel frontal hasta que oiga un clic.
2. Sujetelos goznes ytiredel paraextraerlo, comosemuestraenlailustracin
anterior.
Psele un pao suave seco o lvelo con agua.
No lo empape en agua ms de dos horas.
Squelo bien a la sombra antes de instalarlo.
3. Instaleel panel siguiendolas instrucciones de
extraccin en orden inverso. Cierre el panel
frontal deformaseguraypulselas posiciones
que indican las fechas.
Orifcio
Gozne
Sujete la pestaa
Ou es el hltro de aire de taninos?
Los taninos son biofavonoides que se encuentran en el t verde y que
tienen propiedades tanto antivirales como antioxidantes. Adems de
estas ventajas, los taninos ofrecen tambin excelentes caractersticas
como desodorante. Este fltro de aire utiliza los taninos no slo para
mejorar la calidad del aire, sino tambin para evitar la diseminacin de
bacterias y virus por la habitacin.
Not a:
Limpie los fltros con regularidad para un mejor rendimiento y para re-
ducir el consumo de electricidad.
Salidadeaireyventilador (antesdelimpiar, asegresedequeel ventilador estparado)
Gua
Filtrodeaire
(ltro de aire de taninos)
Lmpi el o c ada 2 semanas
Elimine la suciedad con un aspirador o lvelo con agua.
Squelo bien a la sombra antes de instalarlo.
LIMPIEZA
1
Coloque el defector horizontal
hacia arriba. Acontinuacin, ex-
trigalocomosemuestraen y.
2
Gire hacia afuera los dos defec-
tores verticales uno a uno.
4
Vuelva a colocar los defectores
verticales en su posicin original
uno por uno, en sus guas co-
rrespondientes.
Empuje los deflectores has que oiga un
clic.
3
Limpie la salida de aire y venti-
lador.
Psele un pao suave seco.
5
nstale el defector horizontal
siguiendo las instrucciones de
extraccin en orden inverso.
Si el deflector horizontal no est correc-
tamente instalado, todas las luces de los
indicadores parpadearn cuando se en-
cienda.
2
1
Soltar
Durante la limpieza, apague el disyuntor o desenchfelo de la toma de co-
rriente.
Tenga cuidado de no tocar las partes metlicas con las manos.
No utilice bencina, polvo de pulimentacin ni insecticida.
Use slo detergentes suaves diluidos.
No exponga directamente al sol, al calor o a las llamas ninguna pieza a fn de
secarla.
No use agua con temperatura superior a 50C.
Sp-7
MANUAL DE INSTRUCCIONES
sigue sin funcionar bien, pngase en contacto con su distribuidor.
Sntoma Explicacin y puntos de comprobacin
Unidad interior
La unidad no puede ponerse
en funcionamiento.
Est activado el disyuntor?
Est puesto el enchufe de la alimenta-
cin?
Est confgurada la activacin del tempo-
rizador? Pgina 5
Todas las luces de los indi-
cadores de la unidad interior
parpadean.
Est correctamente instalado el defector
horizontal? Pgina 6
El defector horizontal no se
mueve.
Estn correctamente montados el defector
horizontal y el defector vertical? Pgina 6
Est deformado el protector del ventila-
dor?
Cuando se vuelve a poner en
marcha, la unidad tarda unos
3 minutos en funcionar.
Se trata de una instruccin del microproce-
sador para proteger la unidad. Espere.
El vapor se descarga a travs
de la salida de aire de la
unidad interior.
El aire refrigerado de la unidad enfra
rpidamente la humedad del interior de la
habitacin y la convierte en vapor.
La operacin de oscilacin
del DEFLECTOR HORIZON-
TAL se suspende durante un
tiempo y, a continuacin, se
reanuda.
Es para que la operacin de oscilacin del
DEFLECTOR HORIZONTAL serealicecon
normalidad.
La direccin del fujo de aire
cambia en pleno funciona-
miento.
La direccin del defector
horizontal no puede ajustarse
con el controlador remoto.
Cuando el aire acondicionado sigue funcio-
nando en los modos REFRIGERACIN o
DESHUMIDIFICACIN, despus de llevar
entre30minutos y1horaexpulsandoel aire
hacia abajo, la direccin del fujo de aire se
ajusta directamente en la posicin (1) para
evitar que el agua condensada gotee.
Enel mododecalefaccin, si latemperatura
de la corriente de aire es demasiado baja o
se est eliminando la escarcha, el defector
horizontal se ajusta automticamente en la
posicin horizontal.
El funcionamiento se detiene
durante unos 10 minutos en
modo calefaccin.
Se est desescarchando la unidad exte-
rior.
Espere hasta que acabe el proceso, que
dura unos 10 minutos. (La escarcha se
forma cuando al temperatura exterior es
demasiado baja y la humedad demasiado
alta).
La unidad se pone en marcha
por s misma al conectar
la alimentacin principal,
aunque no con el controlador
remoto.
Estos modelos estn equipados con la
funcin de reinicio automtico. Cuando se
desconecta la alimentacin principal sin
detener la unidad mediante el controlador
remoto y se vuelve a encender, la unidad
se pone en marcha automticamente
en el mismo modo seleccionado con el
controlador remoto justo antes de que se
desconectara la alimentacin principal.
Consulte Funcin de reinicio automtico
pgina 4 .
Multisistema
La unidad interior que no est
en funcionamiento se calienta
y emite un sonido parecido al
agua que corriente.
En la unidad interior, contina circulando
una pequea cantidad de lquido refri-
gerante aunque esta unidad no est en
funcionamiento.
Cuando se selecciona la
operacin de calefaccin, no
se pone en marcha de forma
inmediata.
Cuando se inicia la operacin durante el
desescarchado de la unidad exterior, la
expulsindel aire clido lleva unos minutos
(mximo 10).
Unidad exterior
El ventilador de la unidad
exterior no gira aunque el
compresor est funcionando.
Aunque el ventilador empiece
a girar, se para en seguida.
Cuando la temperatura exterior es baja
durante la operacin de refrigeracin, el
ventilador funciona intermitentemente para
mantener sufciente capacidad de enfria-
miento.
En la unidad exterior hay una
fuga de agua.
DurantelaREFRIGERACINolaDESHU-
MIDIFICACIN, el enfriamientodelos tubos
y de las conexiones de los tubos hace que
se condense el agua.
En el modo de calefaccin, el agua se
condensa en el intercambiador de calor y
empieza a gotear.
En el modo de calefaccin, la funcin de
desescarchado derrite el hielo adherido
a la unidad exterior y el agua empieza a
gotear.
Sale humo blanco de la
unidad exterior.
En el modo de calefaccin, el vapor que
se genera debido al funcionamiento de
desescarchado tiene el aspecto de humo
blanco.
Sntoma Explicacin y puntos de comprobacin
Controlador remoto
La pantalla del controlador
remoto no aparece o se
oscurece. La unidad interior
no responde a la seal del
controlador remoto.
Estnagotadas las pilas? Pgina3
Es correcta la polaridad (+, -) de las pilas?
Pgina 3
Se ha pulsado algn botn del controlador
remoto de otros aparatos elctricos?
No refrigera o no calienta
La sala no se refrigera ni se
calienta lo sufciente.
Es correcto el ajuste de la temperatura?
Pgina 4
Es adecuado el ajuste del ventilador?
Cambielavelocidaddel ventiladoraunvalor
mayor.
Est limpio el fltro? Pgina 6
Estn limpios el ventilador o el intercam-
biador de calor de la unidad interior?
Pgina 6
Hayalgnobstculoquebloqueelaentrada
o salida de aire de las unidades interior o
exterior?
Se ha abierto una ventana o puerta?
La habitacin no se refrigera
lo sufciente.
Cuandoseutilizaunventilador deaireouna
cocina de gas en la habitacin, aumenta la
carga de refrigeracin, con lo cual el efecto
de refrigeracin resulta insufciente.
Cuando la temperatura del aire exterior es
alta, el efectoderefrigeracinpuederesultar
insufciente.
La habitacin no se calienta
lo sufciente.
Cuando la temperatura de aire exterior es
baja, el efecto de calentamiento puede re-
sultar insufciente.
Durante el funcionamiento
en modo de calefaccin, el
aire no circula rpidamente.
Espere hasta que la unidad est lista para
expulsar aire caliente.
Flujo de aire
El aire de la unidad interior
tiene un olor raro.
Est limpio el fltro? Pgina 6
Estn limpios el ventilador o el intercam-
biador de calor de la unidad interior?
Pgina 6
La unidadpuede absorber el olor adherido a
las paredes, alfombras, muebles, prendas,
etc. y expulsarlo junto con el aire.
Sonido
Se oye un ruido de rotura. Se trata de un sonido provocado por la di-
latacin/contraccin del panel frontal, etc. a
causa de los cambios de temperatura.
Se oye un ruido burbujeante. Este ruido se oye cuando, al encenderse
la campana o el ventilador, la manguera de
drenaje absorbe aire del exterior y el agua
que fuye por la manguera sale expulsada.
Este ruido tambin se oye cuando hace
mucho viento y entra aire en la manguera
de drenaje.
Se escucha un sonido mec-
nico en la unidad interior.
Correspondeal sonidodeencendido/apaga-
do del ventilador o del compresor.
Se oye correr agua. Se trata del ruido del refrigerante o del agua
condensada que fuye por la unidad.
A veces se oye un silbido. Se trata del ruido que hace el refrigerante al
cambiar la direccin de la circulacin en el
interior de la unidad.
En los casos siguientes pare el equipo y pngase en contacto con su
distribuidor.
Cuando cae o gotea agua de la unidad interior.
Cuando la luz de indicacin de funcionamiento superior parpadea.
Cuando el disyuntor se desconecta con frecuencia.
Es posiblequelaseal del controlador remotonoserecibaenhabitaciones en
las que se utilicen fuorescentes de accionamiento electrnico (de tipo inversor,
etc.).
El funcionamiento del acondicionador de aire interfere con la capacidad de
recepcin del televisor o la radio. Puede ser necesario conectar el receptor
afectado a un amplifcador.
Si se oye un ruido anmalo.
SI CREE QUE HA OCURRIDO ALGN PROBLEMA
Sp-8
Lugar deinstalacin
Procure no instalar el acondicionador de aire en los siguientes lugares.
Donde haya demasiado aceite para maquinaria.
En ambientes salobres, como las zonas costeras.
Donde haya gas sulfrico, como en zonas de baos termales.
Donde se haya derramado aceite o haya mucho humo aceitoso en el ambiente.
Donde existe equipo inalmbrico o de alta frecuencia.
Donde el aire de la salida de aire de la unidad exterior est bloqueado.
Donde el sonido del funcionamiento o el del aire de la unidad exterior no
moleste a los vecinos.
I nstalacinelctrica
Procurequeel acondicionadordeairedispongadeuncircuitodealimentacin
exclusivo.
Procure que la capacidad del disyuntor sea la adecuada.
Si tiene alguna pregunta, consulte a su distribuidor.
Modelo
Nombre del equipo MSZ-GC25VA(H) MSZ-GC35VA(H)
Interior MSZ-GC22VA MSZ-GC25VA MSZ-GC35VA
Exterior MUZ-GC25VA(H) MUZ-GC35VA(H)
Funcin Refrigeracin Calefaccin Refrigeracin Calefaccin Refrigeracin Calefaccin
Alimentacin ~/N, 230 V, 50 Hz
Capacidad kW 2,5 3,2 3,5 4,0
Entrada kW 0,665 0,835 1,075 1,055
Peso
Interior kg 9
Exterior kg 26 31
Capacidad de depsito de refrigerante
(R410A)
kg 0,75 0,85
Cdigo IP
Interior IP 20
Exterior IP 24
Excesodepresindefun-
cionamiento permisible
LP ps MPa 1,64
HP ps MPa 4,15
Nivel de ruido
Interior (Muy Alto/
Alto/Medio/Bajo)
dB(A) 43/36/29/21 43/36/29/22
Exterior dB(A) 46 47 47 48
Interior
Exterior
MUZ-GC25/35VA MUZ-GC25/35VAH
Refrige-
racin
Margen
superior
32C TS
23C TH
46C TS

46C TS

Margen
inferior
21C TS
15C TH
-10C TS

-10C TS

Calefac-
cin
Margen
superior
27C TS

24C TS
18C TH
24C TS
18C TH
Margen
inferior
20C TS

-15C TS
-16C TH
-20C TS
-21C TH
Not a:
1. Condiciones nominales
Refrigeracin nterior: 27C TS, 19C TH
Exterior: 35C TS
Calefaccin nterior: 20C TS
Exterior: 7C TS, 6C TH
2. GC22 no presenta especifcaciones para combinaciones individuales.
Este modelo para interiores slo se utiliza con aires acondicionados
multisistema.
Para ms informacin sobre las especifcaciones multisistema, pnga-
se en contacto con su distribuidor o consulte el catlogo.
Intervalo garantizado de funcionamiento
LUGAR DE INSTALACIN Y
TRABAJO ELCTRICO
ESPECIFICACIONES
Para evitar los efectos
de una lmpara
fuorescente, mantn-
gase lo ms alejado
posible.
wall, etc.
Lmpara fuorescen-
te de tipo inversor
Mantenga un
espacio sufcien-
te para evitar
distorsiones
en imgenes o
sonido.
1 mo
ms
Radio
100 mmo
ms
Sitio seco y
bien ventilado
100/200 mm
o ms TV
Telfono
inalm-
brico o
porttil
3 mo
ms
1 mo
ms
La unidad exterior debe instalarse por lo menos a 3
m de las antenas para equipos de televisin, radio,
etc. En zonas de mala recepcin, si el funcionamiento
del acondicionador de aire interfere en la recepcin
de emisoras de radio o de televisin, aumente la
separacin entre la unidad exterior y la antena del
aparatoafectado.
1
Ajuste a la mxima temperatura en el modo manual de
REFRIGERACIN, y djelo en funcionamiento durante
3 a 4 horas. Pgina 4
Esto hace que se seque el interior de la unidad.
2
Pulse para que se detenga.
3
Desconecte el disyuntor o desconecte el enchufe de la
alimentacin.
4
Quite todas las pilas del controlador remoto.
Al volver ausar el acondicionador de
aire:
1
Limpie el fltro del aire. Pgina 6
2
Compruebe que no estn bloqueadas las entradas y
salidas de aire de las unidades interior/exterior.
3
Compruebe que el cable de tierra est conectado
correctamente.
CUANDO EL ACONDICIONADOR DE
AIRE NO SE VAYA A UTILIZAR
DURANTE MUCHO TIEMPO
(GC25/GC35)