VariabIe DispIacement Pump A7V

Type Code
Pimp Type
A7V 55 LV 1 L Z F O O
A7V Axial piston variable
Displacement pump
Size
0-20.5
8.1-28.1
0-40.1
15.8-54.8
0-58
23.1-80
0-78
30.8-107
0-117
46.2-160
0-250
0-355
0-500
Displacement Vgmin-Vgmax ml/r)
ControI Device
Constant horsepower
control
Constant pressure
20
28
40
55
58
80
78
107
117
160
250
355
500
LV
DR
EP
control
Electrical control
(with prop.solenoid)
Hydraulic control
pressure related
Manual control
(with handwheel)
Brake control
Numerical control
Series
see section
HD
MA
SC
NC
1
5.1
AuxiIiary Equipment
none
Stroke Limiter
none
Stroke Limiter
mechanically adjustable
(for LV and DR)
Stroke Limiter, hydraulic
(for LV)
Pipe connections
Pressure port:
SAE flange, on side
Suction port:
SAE flange, on side
Pressure port:
Threaded, on side
Suction port:
SAE flange, on side
Shaft End
splined shaft DN 5480
splined shaft GB 3478.1-83
keyed shaft GB1096-79
Direction of Rotation(Viewed of shaft end)
clockwise
anti-clockwise
O
O
M
H
F
G
Z
S
P
R
L
Ordering ExampIe: A7V.55.LV.1.L.Z.F.O.O
Axial piston variable displacement pump A7V,
size 55. With constant horsepower control, series 1.
anti-clockwise rotation, splined shaft
SAE side flange connections, without auxiliary equipment
-51-
BEJNG HUADE HYDRAULC
NDUSTRAL GROUP CO., LTD.
VariabIe DispIacement Pump A7V
for open circuits
Size 20-500
axial tapered piston bent axis design
Peak pressure up to 40MPa
RC92100/12.2004
Replace RC92100/09.2003
Description
Variable displacement pump, axial piston, bent axis design, for hydrostatic transmissions in open
circuits.
The flow if proportional to the drive speed and the displacement and is steplessly variable at constant
drive speed.
Comprehensive programme of control devices for every control and regulation function.
Operation of both mineral, and fire-resistant fluids.
SpeciaI Features
series 1
High performance rotary group with well-proven spherical control area offering the following
advantages ,self-centering, low peripheral speed, high efficiency.
Long service life robust rolling bearing.
Drive shaft will support radial loads.
Low noise level.
High duty roller bearing for inter-mittent high presure operation. For continuous duty hydrostatic
bearing are available.
-52-
VariabIe DispIacement Pump A7V
TechnicaI Data (theoretical values, without considering mech-hyd.and volumetric efficiency)
Size
Control Device
Constant HP control
Constant HP control with load sending
Constant pressure control
Constant pressure control with load sending
Hydraulic control
Electric control (Proportional)
Manual control
Brake control
Numerical control
Displacement
500
20 28 40 55 58 80 78 107 117 160 250 355 500
Vgmax ml/r 20.5 28.1 40.1 54.8 58.8 80 78 107 117 160 250
Max.flow
2
Max.Power
( p=35MPa)
Flow Q
2
Power
P( p=35MPa)
Torque
M( p=10MPa)
( p=35MPa)
Max.torque Mmax
Moment
Weight
Max.speed
3
0.09MPa
1
0.1MPa
1
0.15MPa
1
nmax 0.09
nmax 0.1
nmax 0.15
Qmax 0.09
Qmax 0.1
Qmax 0.15
NE=1450r/min
NE=1450r/min
Vgmax
Vgmin
Vgmax
Vgmin
Vgmin mi/r 0 8.1 0 15.8 0 23.1 0 30.8 0 0 0 0 46.2
nmax 0.09
nmax
nmax
0.1
0.15
Qmax0.09
Qmax
0.1
Qmax
0.15
Pmax0.09
Pmax
0.1
Pmax
0.15
r/min
r/min
r/min
L /min
L /min
L /min
KW
KW
KW
L/min
KW
Nm/10MPa
Nm/10MPa
Nm
Nm
kgm
kg 19
0017
114
17
28.8
57
49
45
94
82
76
4750
4100
3800 2800
3000
3600
76
82
98
46
49
59
39.5 56.4
88
80
75
146
132
124
3750
3400
3200 2360
2500
3000
125
133
160
75
80
24
44.6
12.9
156
45
0.00170
19 28 28
00520 00520
223
88
305
25.1
63.7 87
34 46 50
77.1
96
2850
3000
3350
161
170
190
97
102
114
82.3
93.2
326
01090 0109
44 44 53 53
0.0167 0.0167 0.0322
76 76 105 165 245
257 171
2120
2240
2750
164
174
213
99
105
128
112.5
109.7
136
123
116
227
204
192
3000
2700
2540 1900
2000
2450
197
208
254
119
125
153
150.5
91
66
68
127.5
36.8
124
446
129
431 594
49
169.7
2240
2360
2650
254
267
300
153
161
181
164.6
186
99
651 889
73.5
254
135
225
196
163
154
326
271
256
2100
1650
1750
1400
1500
1850
340
364
449
204
218
270
397.5 564.5 795
1391 1975 2782
342
273
259
568
455
430
1650
1320
12501120
1200
1500
543
582
728
326
350
437
l)The values shown are valid for Vgmax.with an absolute pressure at suction inlet Sand when operated on mineral oil.
2)Calculated with a volumetric efficiency of 97%.
3)The maximum speeds at 0.15MPa shown must not be exceeded ,even with higher loading. On those sizes with Vgmin >0,
however the maximum speeds can be increased to the values for those sizes with Vgmin =0 by reducing the displacement ( Vg
<Vgmax) and maintaining max.flow. The relevant sizes are 28-20,55-40,80-85,107-78,160-117.
Permissible speed npern and suction pressure pabs can be read from the
nommograph. However, the max,speeds(see table)and min. and max.
suction pressure must be taken into account.
Example: Given: size 55D rive speed 2700r/ min Required: pressure Pabs at
the suction inlet.
Solution: Line1 on scale nperm drawn towards size 55 crosses line Hat portA.
Line 11 from point Ato point B(open circuit) gives the result Pabs=0.117MPa.
LV
LVS
DR
DRS
HD
EP
MA
SC
NC
355
__ __ __
__ __ __ __ __ __ __
__ __
__
__
__
__
__
__ __ __
2
32.6
0.0322 0.0880 16000 270
__
__
J
-53-
VariabIe DispIacement Pump A7V
TechnicaI Data
nlet operation Pressure
Absolute pressure at port S
Pabs min_____________0.08MPa
Pabs max_____________0.2MPa
Operating Pressure Range-Outlet Side
Nominal pressure__________pN=35MPa
Peak pressure__________pmax=40MPa
FIuid Temperature Range
tmin___________________-25C
tmax___________________+80C
Viscosity Range:
Vmin_________________10mm /s
2
2
Vmax_________________(for short periods)1000mm /s
Optimun Operating Viscosity:
Vopt_____________________16-36mm /S
2
FIuid Recommendation:
Operating
Range
30-40 C VG22 . 22mm /s
2
40-50 C VG32 . 32mm /s
2
50-60 C VG46 . 46mm /s
2
60-70 C VG68 . 68mm /s
2
70-80 C VG100 . 100mm /s
2
when mounting outside a
tank, the pump must be bled
at port U1 or U2 prior to
commissioning.
Mounting on Top of Tank
Mounting of the A7V variable
pump above tank must be
considered as a special pump
nstallation and should only be realized under specific conditions. When ordering pumps for
mounting on top of tank, state in clear text: "To Be Used for Above Tank Mounting"
This installation requires that the suction port be at the top and the suction pipe be kept as
short as possible and the end of the pope be at least 200mm below minimum oil level, see
Fig2.
The cross-cut of the suction pump should be so dimensioned to ensure that the flowvelocity
of the pressure fluid lies between 0.8 and 1m/s.
FiItration of HydrauIic FIuid
Recommended filtration 10 m Coarser filtration of 25-
40 m is possible, but longer component life, will be
achieved using 10 m filtration due to lowest component
wear.
Mounting Position

Optional, The pump housing must always be filled with
oil. When mounting within a tank the plug must be
removed form port R and this port must be at the top.
90Cpipe bend to be screwed in (noise reduction).
Note:
Vertical mounting with drive shaft pointing upwards: for
this case a model with ports U1 and U2 must be ordered
(indicate in clear text: "with ports U1 and U2 ").The
minimum oil level must not fall below the "A" line, as
shown is Fig1.
Size
Max
speed
Max
length
of Suction
pipe
Lmax (mm)
Calculated suction pie 1.D.
(mm) at flow velocity
V=0.9m/s and Vgmax.
speed
speed
nmax
(r/min)
nE
=1450(r/min)
nmax
r/min
20
28
40
55
58
80
78
107
117
160
3610
2660
3040
2240
2700
2015
2410
1800
2125
1565
600
600
750
750
750
750
750
750
850
850
41.8
42
53.6
53.8
61.3
61.6
66.6
67.5
76.6
77
26.5
31
37
43.3
45
52.3
51.6
60.5
63.3
74
1) The values shown are valid for Vgmax with 0.09MPa absolute pressure at
suction inlet Sand when operated on mineral oil.
Note:
Start-up of the pump with all controls is only possible when the pump is at its
full swivel angle (Vgmax), For pumps with minimum flowof >5% of Vgmax. in
order to avoid emptying of the suction line during zero position operation.
to DN51519
Recommended Viscosity grade
SO(VG) (at 40C)
Temperature
-54-
VariabIe DispIacement Pump A7V
Calculation of nlet Pressure Pabs at Suction nlet S and
of Reduction in Displacement at ncreased Speeds.
Size 250-500
ExampIe:
Given:
Size 500
Drive speed 1320rpm
Required:
pressure Pabs at suction inlet S
Solution:speed ration
n
nmax0.1
=
1320
1200
= 1.1
gives an inlet pressure of Pabs=0.12MPa
at full swivel for example free flow is only possible with
Pabs =0.12MPa, the displacement must be reduced to 87.6%
nmax = Max, perm speed.
Displacement Vg
Vgmax
Size
nmaxperm(T/min)
CaIcuIation of Size
2500
250
355
2240 2000
500
Flow Q=
Vg.n.qv
1000
Drive Torque
Drive Power
M=
1.59.Vg. P
10.qmh
P=
M.n
9549
=
Q. P
60qt
[L/min]
[Nm]
[KW]
Constant Horsepower ControI
geom.displacement per rev(ml/r)
differential pressure(MPa)
speed(r/min)
mech.hyd.efficiency
The constant HP control controls flow in relation to pressure.
thereby maintaining hydraulic power constant.(Provided that the
drive speed is constant.)
By means of a mechanical or hydraulic stroke limiter, the max.
displacement can be infinitely varied or limited. Adjustment range
from Vgmax to Vgmin
P=
P.Q
60
=Constant
___
P= power[KW]
P=pressure[MPa]
Q=flow[L/min]
Commencement of controI:min.5MPa
Summation HP control possible by throttles via port G.
Constant HP control
LV with mechanical
stroke limiter
Size
Spindle
Required Torque
(approx.)Ncm
20
28
23
40
55
21
58
80
28
78
107
31
117
160
26
250
21.25
355
24 25
500
Revolutions
80 140 500 630
Constant HP control LV
Vg
P
n
qv
qmh
qt
[qt=qv.qmh]
__ __ __
volumetric efficiency
overall efficiency
Stroke Limiter :
-55-
For all sizes with Vgmin=0
The pressure cut-off is a constant pressure control superposed on the constant HP control and is carried out by means of a sequence
valve, when the set. maximum pressure is reached (adjustment range
up to 315MPa),the valve opens and the flowis automatically reduced (to Q=0).
The sequence valve is mounted separately from the pump in any suitable location one subplate (remotecontrol).
The max./single pipe length must not exceed 5 m. order sequence valve and subplate separately.
When using the constant HPcontrol with pressure cut -off, the pump control times, will be approximately 3 times longer than those obtained
with the constant pressure control DR. mportant : Port T form the sequence valve and pilot oil return line Tl must be piped direct to tank
(cooler).Continuous operation in zero position see constant pressure control DR.
Constant HPcontrol LVwith pressure cutoff (remote controlled)and hydraulic stroke limiter
Connections
A.B service lines
S suction-line
G port for
Summation HP control line
X1 pilot pressure
X2 remote contr.pressure
A1. X3 control valve
T1 pilot oil retum
R air bleed
remote control valve
with Pressure Cut-Off
Pa (KW)
Size
Speed
Max.Flow Q at no
Drive without pressure
cut-off power
range
P.(KW) with pressure cut-off
Conversion to speeds n(rpm) other than n.
Drive power P=P0
n
____
no
no r/min
L/min
Pomin
Pomax
Pomin
Pomax
20
1450
28
3
11
3
10
15
4
39
1450 1450
57
5.5
18.5
5.5
30
7.5
77
1450
55 40 28 58
1450 1450
80
81
7.5
30
7.5
27 18.5
110.5
11
37
37
37
11
11
110
1450 1450
78 107
150
15
45
55
15
55
15
165
1450 1450
117 160
225
22
75
90
22
90
22
237
980
250 355
980
337
30
132
30
132 200
45
200
45
475
980
500
1. Calculated with a volumetric efficiency of 97%
VariabIe DispIacement Pump A7V
-56-
Variation: Constant HPControI with Load Sensing
The load sensing valve is a flow control valve which operates as function of the
load pressure to regulate the pump displacement in order to match the
requirement of the consumer unit. The pump flow is influenced by the external
orifice (control black, throttle) fitted between pump and serviced unit , ber curve.
The valve compares pressure before and after the orifice and maintains the
pressure before and after the orifice and maintains the pressure drop
(differential pressure P)across the orifice and therefore the pump flow-
constant. if differential pressure P increases, the pump is swivelled back
towards Vgmin and if Pdecreases the pump is swivelled out towards Vgmax, until a
balance is restored within the valve.
P=Pserviced unit
P may be set with the range 14 bar to 25 bar. The standard setting is 18 bar
(please state required setting in clear text). The stand by pressure for zero stroke
operation (orifice close)is approx.2 bar above the P setting. The constant
power control and the pressure cut -off are super imposed on the load sensing
valve, for example the set power hyperbola and set pressure the orifice is not
included in the standard, in the standard supply.
Constant Pressure ControI
The constant pressure control maintains the pressure in a hydraulic system
constant within its control range in spite of changing pump flow requirements.
The variable pump supplies only the volume of fluid required by the services,
Should operating pressure exceed the set pressure, the pump is automatically
swivelled back to a smaller angle. The required pressure is set either direct at
the pump (valve built in standard model) or at the separate sequence valve for
the model with remote control.
Setting range from 5 to 35MPa.
Setting range for remote control 5 to 31.5MPa.
-57-
VariabIe DispIacement Pump A7V
Stoke Limiter
The max. displacement can be steplessly limited between Vgmax to Vgmin
by means of a mechanical stroke limiter.
For details see control device LV.
Continuous Operation in Zero Position

Zero stroke operation without flushing of housing.
short periods <10min
(~50% ED)
max.perm
pressure
max.perm
tank temperature
pmax (MPa)
31.5 50
tmax (C)
max.perm
pressure
pmax (MPa) tmax (C)
20 50
Zero stroke operation with flushing of housing
Note:
Order sequence valve subplate separately The max. single pipe
length should not exceed 5m. Port T from the sequence valve
must be piped separately to tank Apressure relief valve installed
in the system for protection of the max. pressure must be set
2MPa above the setting of the constant pressure control.
max.perm
pressure
long periods
max.perm
tank temperature
pmax(MPa)
31.5
tmax(C)
50
FIushing fIow
Size
flow Qsp 1/min
20
2 4
40 58
6 8
78 117
12
250
12.5 16
355 500
25
Temperature of fIushing fIuid < tank temperature
Note : When mounting the A7V on top of tank and at zero stroke
operation for longer periods of time at pressures up to Pmax 31.5MPa a
minimum flow >corresponding to flushing flow as indicated for each
size in the above table must be set instead of case flushing.
The values in the table are increased by 3 time for remote control.
For parallel operation of several A7V pumps with constant
pressure control a steeper curve is used for the constant pressure
control.
please indicate this requirement in text after the type code when
order in ("parallel operation").
For parallel operation each individual pump requires its own
sequence valve.
Size
Vgmin-Vgmax
35-5MPa
Pressure unloading
Vgmax-Vgmin
5-35MPa
Pressure built-up
ta(S)
te(S)
20
0.16
0.03 0.04
0.2
40 58
0.25
0.05
0.25
0.05
78
0.06
0.3
117
Adjustment times
Size
Typical values at speed
n=1450rpm
fluid temperature=50C
Power at zero stroke (KW)
Power at Zero Stroke
long periods
max.perm
tank temperature
-58-
VariabIe DispIacement Pump A7V
VariabIe DispIacement Pump A7V
The load sensing valve is a flow control valve which operates as function of the load pressure to
regulate the pump displacement in. order to match the requirement of the consumer unit. The pump
flowis influenced by the external orifice (control black, throttle) fitted between pump and serviced unit,
but is not affected by load pressure throughout the range belowthe power curve. The valve compares
pressure before and after the orifice and maintains the pressure before and after the orifice and
maintains the pressure drop (differential pressure P)across the orifice-and therefore the pump flow-
constant. if differential pressure Pincreases, the pump is swivelled back to words Vgmin' and if P
decreases the pump is swivelled out towards Vgmax' until a balance is restored with in the valve.
P=Ppump-Pserviced unit
P may be set with range 14 bar to 25 bar. The standard setting is 18 bar (please state required
setting in clear text) The stand by pressure for zero stoke operation (orifice close) is approx. 2 bar
above the P setting. The constant pressure control is superimposed on the load sensing valve, i, e,
the load sensing function operates below the set pressure. The orifice is not included in the standard
supply.
Variation:Constant Pressure controI with Load sensing
-59-
VariabIe DispIacement Pump A7V
EPEIectric ProportionaI ControI
The electric control permits stepless and programmable adjustment of
the solenoid force i.e. the strength of solenoid current. The control force
on the control piston is generated by a proportional solenoid. The
proportional solenoid need a 24V(12V)DC power supply that the
current is 300_630mA (600_l260mA). commencement of control at
approx. 300mA(600mA).
End of control at approx.630 mA(1260mA). Adjustment is from Vgmin to
Vgmax. please consult us if control in the opposite direction (Vgmax to Vgmin)
required,
if the pump is to be moved out of the zero position <Vg=0) or if the
operating pressure<4MPa,a pilot pressure of 4Mpa is necessary at
port G.
Adjustment Times
Size
Vgmin-Vgmax tmin
Vgmax Vgmin tmin
20
28
0.16
0.12
40
55
0.2
0.16 0.2 0.2
0.25 0.25
80 107
58 78 117
160
0.3
0.25
XThe values shown are valid for operating pressure Pb=20MPa,
Hysteresis
Ahysteresis of2.5 to 4%(approx.) is present in the control because of
the electric/hydraulic control (referred to the complete adjustment,
range Vmin to Vgmax). The repeatability of the pump position, when
starting from the same direction, is around 2-4%.
Note:
Mounting of the pump with EP. control inside the oil tank is possible,
only when using mineral hydraulic oil and with a max. oil temperature
in the tank of 80C .if the pump is to be submersed in oil, please
indicate in clear text when ordering). Auxiliary Equipment: Pressure
Cut-Off
For all sizes with Vgmin=0.
For description see control device HD.

Order sequence valve and subplate separately
Commencement of control at Vgmin
Vg
Vgmax
______
Line adapts for Vgmax >250ml/r Line || adapts for Vgmax <250ml/r.
EP Electric Pro. Control with Pressure cut-off
Connections
A,B Service lines
S. Suction line
G. Remote control pressure
R. air bleed
A1, X3 Ports for remote control valve
(s)
(s)
X
X
-60-
ManuaI ControI
By turning the handwheel, a piston is is moved in an axial direction by
means of a threaded spindle. Acarrier pin moves the control lens on its
sliding plane, thus permitting stepless variation of the pump
displacement in the range Vgmin to Vgmax. The pump position indicator is
located in the handwheel.
HydrauIic ControI, Pressure ReIated
The hydraulic control pressure related, permits the stepless
adjustment of the pump displacement in relation to pilot pressure
Adjustment is proportional to the pilot pressure at port X. When using
the Hd control ax 2-position control (Vgmin to Vgmax) the pilot oil pressure
on port X must not exceed 4MPa.
Adjustment is from Vgmin to Vgmax . The increase in pilot pressure over the
complete adjustment range(min-max)is 1MPa.
The setting range for commencement of control is between 0.4 and
1.5MPa. The necessary control oil is taken from the high pressure
circuit, and a minimum operating pressure of 4MPa is required. f
necessary apply pilot pressure of 4MPa at port X2.
The oil flowat pilot X is approx 0.5L/min.
AdditionaI Function; Pressure cut-Off
For all sizes with Vgmin=0.
The pressure cut-off serves to limit the flow as a function of
the high pressure so that a predetermined operating
pressure is not exceeded. This function is carried out by a
sequence valve. On reaching the set maximum pressure
(adjustment range up to 31.5MPa),the valve opens and the
flowis automatically reduced (to Q=0).
The sequence valve is mounted separately from the pump in
any suitable location by means of a subplate (remote
control).The max, Single pipe length should not exceed 5m.
Order sequence valve and subplate separately.
Hydraulic Control, pressure related, HD with pressure cut-off
mportant: port T from the sequence valve must be piped
separately to tank.
Continuous Operations is Zero position
For details see constant pressure control DR.
Connections
A,B service lines
S. suction line
X1 pilot pressure
X2 remote control pressure
A1, X3 ports for remote control valve
R. air bleed
-61-
VariabIe DispIacement Pump A7V
VariabIe DispIacement Pump A7V Unit dimensions Size 20-160 LV: Constant HP Control
Unit dimensions Size 20-160
LV Constant HP Control
-63-
VariabIe DispIacement Pump A7V
VariabIe DispIacement Pump A7V
AuxiIiary equipment : hydrauIic stroke Iimiter (for LV)
AuxiIiary equipment : mechanicaI stoke Iimiter (for LV-and DR)
Connections
service lines
suction line
remote control pressure M14 x 1.5
(connection for summation HP control)
pilot pressure M14 x1.5
remote control pressure (HD) M14 x 1.5
ports for remote control valve
pilot oil return line M12 x 1.5
pilot oil return line
air bleed
Size
20
28
40
55
58
80
78
107
117
160 16
9
16
9
16
9
16
9
16
9
a A1
251
260
317
327
374
385
381
393
443
454 414
402
358
347
347
337
296
287
232
224
A2 A3
199
195
255
251
304
300
310
305
364
359 213
214
145
152
152
123
123
107
107
A4 A5 A6
75
75
108
108
137
137
130
130
156
156 40
40
40
40
32
32
32
32
25
25 16
A7
16
20
20
23
23
25
25
28
28 36
36
28
28
28
28
28
28
19
19
A8 A9
43
43
35
35
40
40
45
45
50
50
350
298
295
244
149
160
A10 A11 A12
100
100
125
125
140
140
160
160
180
180
130
113
106
95
95
85
A13 A14
20
34
23
41
26.5
48
29
50
33
58 88
93
80
80
77
77
63
63
50
52
A15 A16
35.7
37.5
42.9
42.9
50.8
50.8
50.8
50.8
61.9
61.9 75
75
63
63
63
63
50
50
38
38
A17 A18
69.9
69.9
77.8
77.8
88.9
88.9
88.9
88.9
106.4
106.4 135
135
115
115
115
115
102
102
94
94
A19 A20
78
59
87
64
93
68
101
73
114
83 222
195
200
180
194
168
182
166
145
132
A21
M12
M12
M12
M12
M12
M12
M12
M12
M16
M16 21
24
20
20
20
20
20
20
20
20
deep A22 A23 A24 A25
95
80
109
91
113
120
120
98
137
112 M16
M16
M12
M12
M12
M12
M12
M12
M8
M8 118
118
150
150
165
165
190
190
210
210 34
34
33
33
33
33
29
29
23.5
23.5
A26 A27
11
11
13.5
13.5
13.5
13.5
17.5
17.5
17.5
17.5 224
224
200
200
180
180
160
160
125
125
Size
20
28
40
58
55
80
78
117
107
104 160
104
89
89
86
86
71
71
58
A28 A29
58 58
58
81
81
92
92
93
93
113
113 354
359
301
306
297
301
249
253
189
193
A30 A31
261
313
318
369
66.7
66.7
57.2
57.2
57.2
57.2
50.8
50.8
50.8
50.8
A32 A33
19
19
19
19
25
25
25
25
32
32 31.8 70
31.8 70
27.8 64
27.8 64
27.8 64
27.8 64
23.8 53
23.8 53
23.8 46
23.8 46
A34 A35 A36
19
33
23
40
26
47
28
19
32
57
136
119
109
98
A37 A38 deep
M10
M10
M10
M10
M12
M12
M12
M12
M14
M14 19
19
18
18
18
18
17
17
17
17
A39
M18 x1.5
M18 x1.5
M18 x1.5
M18 x1.5
M48 x 2
M45 x 2
M42 x 2
M42 x 2
M42 x 2
M42 x 2
M33 x 2
M33 x 2
M27 x 2
M27 x 2
A40 A41 A42
27.9
27.9
32.9
32.9
38
38
43.1
43.1
48.5
48.5 45
45
35
40
40
35
30
30
25
25 50
A43
50
60
60
70
70
80
80
90
90 65
65
55
55
62
62
40
40
38
38
A44 A45
M3
M3
M4
M4
M5
M5
M5
M5
M5
M5 12.5
12.5
12
12
12
12
10
10
9
9
deep A46
257
269
323
337
378
391
385
400
445
461 420
408
363
342
354
344
299
290
234
226
A47 A48
230
2420
279
292
330
343
338
351
384
399 192
192
169
169
155.5
155.5
134
134
108
108
A49 A50 A51 A52
42
42
8.8
8.8
11.2
11.2
18
18
18
18
18
18 65
65
52
52
8
8
10
10
16
16
16
16
16
16
size
20
28
40
55
58
80
78
107
117
160 266
266
236
236
228
228
184
184
161
161
A53 A54 A55
14
14
16
16
24
24
24
24
24
24
176
186
204
215
251
265
261
276
294
310 79
111
71
99
65
91
62
85
58
77
A56 A57
104
84
117
98
116
91
124
97
137
108 137
164
126
150
120
142
128
147
144
129
A58 A59
35
35
30
30
33
33
33
33
34
34 34
34
33
33
33
33
30
30
30
30
A60 A61 A62
228
238
276
288
328
339
336
348
382
396 96
125
86
112
80
104
83
104
73
92
GB1096 79
2 x 10
2 x 10
3 x 10
3 x 10
5 x 16
5 x 16
5 x 16
5 x 16
5 x 16
5 x 16 14 x 70
14 x 70
12 x 63
12 x 63
10 x 56
10 x 56
8 x 50
8 x 50
8 x 40
8 x 40
GB1096 79 DN5180
EXT18Z x 1.25m x 30R x 5f W25 x 1.25 x 18 x 9g
W30 x 2 x 14 x 9g
W30 x 2 x 14 x 9g
W35 x 2 x 16 x 9g
W35 x 2 x 16 x 9g
W40 x 2 x 18 x 9g
W40 x 2 x 18 x 9g
W45 x 2 x 21 x 9g
W45 x 2 x 21 x 9g
GB3478.1 83
EXT18Z x 1.25m x 30R x 5f
EXT14Z x 2m x 30R x 5f
EXT14Z x 2m x 30R x 5f
EXT16Z x 2m x 30R x 5f
EXT16Z x 2m x 30R x 5f
EXT18Z x 2m x 30R x 5f
EXT18Z x 2m x 30R x 5f
EXT21Z x 2m x 30R x 5f
EXT21Z x 2m x 30R x 5f
R1
12
12
12
12
12
12
12
12
12
12 M22 x 1.5
M22 x 1.5
M18 x 1.5
M18 x 1.5
M18 x 1.5
M18 x 1.5
M18 x 1.5
M16 x 1.5
M16 x 1.5
M16 x 1.5
R A1 X3
M12 x 1.5
M12 x 1.5
M12 x 1.5
M12 x 1.5
M18 x 1.5
M18 x 1.5
M18 x 1.5
M18 x 1.5
M20 x 1.5
M20 x 1.5 76
76
53
53
44
44
28
28
19
19
kg
145
___
___
___
___
___
___
A, B
S.
G
X1
X2
A1,X3,
T1
T
R.
52
52
(T1)
Keyed Keyed Splined Splined Connection Connection Weight
A63
W25 x 1.25 x 18 x 9g
-64-
VariabIe DispIacement Pump A7V
DR Constant Pressure ControI
Standard ModeI
Remote ControI DetaiI z
a A1 A2 A3 A4 A5 A6 A7 Size
20
40
58
78
117 9
o
9
o
9
o
9
o
9
o
251
315
372
380
441 199
180
160
166
134 95
107
107
114
132
106
127
138
147
165
38
40
62
60
65
14
15
14
14
53
69
70
83
A1 and X3 only for remote control
Other dimensions see LV.
T1: M12 x 1.5
HD HydrauIic ControI, Pressure ReIated
Size a A1
A2 A3 A4 A5 A6 A7
20
28
40
55
58
80
78
107
117
160 16
o
9
o
16
o
9
o
16
o
9
o
16
o
9
o
16
o
9
o
248
253
312
318
367
373
375
382
434
442 308
333
270
292
266
287
217
236
158
175 132
143
151
166
158
175
170
188
188
209 272
250
245
225
232
213
220
206
195
182 75
75
110
84
110
105
122
106
132
114 305
331
266
290
263
285
212
233
172
190 147
160
166
180
170
186
182
200
200
220
A1 and X3 with pressure cut-off only
EP EIectric ProportionaI ControI
Size
20
28
40
55
58
80
78
107
117
160
a
16
o
9
o
16
o
9
o
16
o
9
o
16
o
9
o
16
o
9
o
A1
A2 A3 A4 A5 A6 A7
248
252
312
318
367
373
374
381
434
442
182
188
267
217
320
325
325
330
381
387
144
130
201
184
249
231
254
234
294
272
113
121
130
140
141
154
153
167
172
187
54
41
49
29
52
29
55
31
64
36
216
229
234
249
245
264
257
277
279
298
75
75
110
84
110
105
122
106
132
114 A1 and X3 with pressure cut-off only
Other dimensions see LV.
Other dimensions see LV.
__ __
-65-
VariabIe DispIacement Pump A7V
MA ManuaI ControI
handwheel downwards
Size
20
28
40
55
58
80
78
107
117
160
a
16
o
9
o
16
o
9
o
16
o
9
o
16
o
9
o
16
o
9
o
450
441
390
380
380
327
323
315
260
251
A1 A2 A3 A4
108
108
134
134
155.5
155.5
169
169
192
192 285
261
270
246
235
215
215
197
190
175 95
80
108
89
107
107
132
92
144
86
Size a A1 A2 B1 B2
16
o
9
o
9
o
9
o
16
o
9
o
16
o
16
o
19
o
26.5 250
160
117
107
78
80
58
40
28
20
317
315
383
445
584 120
100
100
1000
100 175
180
270.5
225
320
230
143
132.5
157.5
132.5
handwheel upwards
Please give clear indication of the
handwheels are upwards or
downwards, when you order
goods!
NC Numerical Control
Size a A1
B1
B2
107 16
o
419 225.5 224.5
LVS Constant HP Control with Load Sensing
Size
a
A1
B1 B2
117 9
o
443 215 137
DRS
Constant Pressure Control with Load Sensing SC
Size a A1 B1 B2
117 9
o
441 214 132
Size a A1
B1 B2
SC Brake Control
160 441 230 98
__ __ __ __
__ __ __ __
__
__
__
__
__
__
__
__
__
__
__
__
16
o
-66-
VariabIe DispIacement Pump A7V
Unit dimensions Size-250
Constant HP control
-67-
VariabIe DispIacement Pump A7V
DR Constant Pressure ControI
Standard ModeI Remote ControI DetaiI z
service lines
suction line
remote control pressure M14 x 1.5
(connection for summation HP control)
ports for remote control valve M16 x 1.5
flushing port M14 x1.5
pilot pressure M14 x 1.5
remote control pressure (HD) M14 x 1.5
pilot oil return line M16 x1.5
pilot oil return line M22 x1.5
air bleed M22 x 2
A,B
S
G
A1,X3
U
X1
X2
T
T1
R.
-68-
VariabIe DispIacement Pump A7V
Unit dimensions Size-355
LV Constant HP control
-69-
DR Constant Pressure ControI
Standard ModeI
Remote ControI DetaiI z
service lines
suction line
remote control pressure M16 x 1.5
(connection for summation HP control)
pilot pressure M16 x 1.5
remote control pressure (HD) M16 x 1.5
A,B
S
G
X1
X2
ports for remote control valve M22 x 1.5
A1, X3
pilot oil return line M16 x1.5 T
pilot oil return line M22 x1.5
T1
air bleed M33 x 2 R
flushing port M14 x 1.5 U
-70-
VariabIe DispIacement Pump A7V
Unit dimensions Size-500
LV Constant HP control
-71-
VariabIe DispIacement Pump A7V
DR Constant Pressure ControI
Standard ModeI Remote ControI DetaiI z
service lines
suction line
remote control pressure
(connection for summation HP control)
pilot pressure M16 x 1.5
remote control pressure (HD) M16 x 1.5
ports for remote control valve M22 x 1.5
pilot oil return line M16 x1.5
pilot oil return line M22 x1.5
air bleed M33 x 2
flushing port M14 x 1.5
A,B
S
G
X1
X2
A1, X3
T
T1
R
U
-72-
VariabIe DispIacement Pump A7V
Notice
1. The fluid must be filtered. Minimum filter fineness is 20 m.
2. The tank must be sealing up and an air filter must be installed on air entrance.
3. Products without subplate when leaving factory, if need them, please ordering specially.
4. Valve fixing screws must be high intensity level (class 10.9). Please select and use them
according to the parameter listed in the sample book.
5. Roughness of surface linked with the valve is required to .
6. Surface finish of mating piece is required to 0.01/100mm.
All rights reserved-Subject to revision
THM Huade Hydraulics (P) Ltd