You are on page 1of 130

Siemens

The reproduction, transmission or use


of this document or its contents is not
permitted without express written
authority. Offenders will be liable for
damages. All rights, including rights
created by patent grant or registration
of a utility model or design, are
reserved.
Print No.:
SiemensLandgraf
AXIOM Artis FC/FA
System
Planning Guide
AX
2001
AXA4-100.891.01.06.02
Replaces: AXA4-100.891.01.05.02
English
Doc. Gen. Date: 01.08
AXIOM Artis FC/dFC/FA/dFA (e)
05904433 05904441 07412807 07555373
2 Revision / Disclaimer
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 2 of 130
1Revision / Disclaimer
Document revision level
The document corresponds to the version/revision level effective at the time of system
delivery. Revisions to hardcopy documentation are not automatically distributed.
Please contact your local Siemens office to order current revision levels.
Disclaimer
The installation and service of equipment described herein is to be performed by qualified
personnel who are employed by Siemens or one of its affiliates or who are otherwise autho-
rized by Siemens or one of its affiliates to provide such services.
Assemblers and other persons who are not employed by or otherwise directly affiliated with
or authorized by Siemens or one of its affiliates are directed to contact one of the local
offices of Siemens or one of its affiliates before attempting installation or service proce-
dures.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Table of Contents 3
Page 3 of 130

0Table of Contents
1 _______ General Information______________________________________________ 6
System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Definition of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Abbreviations Used. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Additional Information for Detailed Planning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2 _______ Room Planning ________________________________________________ 10
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Product-specific Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Requirements for Lighting per DIN 6868-57 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Room Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Recommendation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
System with DCS Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Top-down View of System without the MULTISPACE.F Option . . . . . . . . . . . . . . . . 12
Top-down View of System with MULTISPACE.F Option . . . . . . . . . . . . . . . . . . . . . . 13
System with a second DCS Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Top-down View of System with a Second DCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Additional Work Positions with the MULTISPACE.F Option . . . . . . . . . . . . . . . . . . . 18
System: DCS Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
System: Side View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Planning Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Movement Ranges of the Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Max. admissible Floor Unevenness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Floor Stand: Side View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Floor Stand: Side View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
with Image Intensifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Floor Stand: Top-down View of dFC/FC/FA/dFA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Patient table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Notes regarding the OR table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Positioning of Cabinets and Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Control Room. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Static Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Floor Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
DCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Patient table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
3 _______ Installation Preparations_________________________________________ 40
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Required Aids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Floor Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4 Table of Contents
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 4 of 130
Patient Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Injector Floor Outlet Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
DCS (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Control Room Distributor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
DVD Recorder + 17" Color Display (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Reference Display (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Second Data Display (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Control Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Cooling System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Lower Body Radiation Shield (Option). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Upper Body Radiation Shield, Surgery Lamp, Injector (Option) . . . . . . . . . . . . . . . . 42
Wireless Footswitch (Option). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Component Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Floor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Ceiling Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
On-site Electrical Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Notes regarding the recommendations on the following pages for electrical installation
in accordance with DIN VDE 0100-710. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Recommendation for Application Group 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Recommendation for Application Group 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
On-site Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Siemens Remote Services (SRS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
DICOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Injector Floor Outlet Option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
The following manufacturers have been released: . . . . . . . . . . . . . . . . . . . . . . . . . . 67
4 _______ System Connections ____________________________________________ 69
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Overview of System Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
List of Fixpoints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Maximum Fixpoint Distances and Planning Cable Channel Sizes . . . . . . . . . . . . . . 71
List of Fixpoints Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Laying Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Calculating the Required Cable Channel Cross Section . . . . . . . . . . . . . . . . . . . . . . 75
Remarks regarding Laying Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Control Room Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Image System in the Control Room (Standard). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Image System optionally in the Equipment Room. . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Room Light, Radiation Display, Door Contact, EPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
5 _______ Technical Data _________________________________________________ 82
Dimensions, Weights and Heat Dissipation,... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Examination Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Equipment Room. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Control Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Climatic Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Table of Contents 5
Page 5 of 130
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Paint Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Transport and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
6 _______ Transport and Storage Conditions_________________________________ 90
Packaging and Transport Routes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
7 _______ Detail Planning_________________________________________________ 91
Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
System Control Cabinets #1 / #2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Image System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Floor Stand Ceiling Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Control Room Distributor (BTEE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Control Consoles (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Tabletop Opening for Control Modules and ECC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Second Data Display (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Stationary Upper Body Radiation Shield, Surgery Lamp (Option) . . . . . . . . . . . . . . . . 105
Movable Upper Body Radiation Shield, Surgery Lamp (Option) . . . . . . . . . . . . . . . . . 108
Control Console Cart Ceiling Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
System Ceiling Installation with Monitor Trolley Option . . . . . . . . . . . . . . . . . . . . . 111
Control Console Cart (option). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Injector Wall Connection Box (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Planning Recommendation for the Injector Wall Connection . . . . . . . . . . . . . . . . . 118
Injector Rack Mount Unit (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Connection of non-Siemens ECGs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
DCS Location per Version 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
System without the MULTISPACE.F Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
System Ceiling Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Ceiling Installation with a second DCS (Option). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
8 _______ Changes to Previous Version____________________________________ 130
6 General Information
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 6 of 130
1- 1General Information
System Configuration 0
This Planning Guide has been prepared for the AXIOM Artis dFC/FC/dFA/FA systems. This
consists of:
floor stand + patient table (4 different versions) + DCS or monitor trolley
Fig. 1: System configuration
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
General Information 7
Page 7 of 130
Notes 1.1
General Information 0
There must be a note referring to the installation and delivery conditions of the Med
group on all construction plans produced by the Planning Departments.
The installation and delivery conditions must be enclosed with the plans when shipped.
The requirements of the relevant fire protection regulations must be observed for the
premises.
The system was developed in accordance with IEC 60 601-1
The system does not meet the requirements for AP Classification. Use in areas with
explosive atmospheres as defined by IEC 610-1, Main Section 6, is not permitted.
The AXIOM Artis OR patient table is splash-proof (IPX4 according to IEC 60 601-2-46).
Unless otherwise stated, all dimensions in this document are in mm.
Definition of Terms 0
Technically possible area, orientation points, etc.
Technically possible area, minimum length, minimum width
The technically possible area is a rectangle formed by the required minimum length and
width representing the space required for a system component. The following stipula-
tions apply for the technically possible area:
a) It is the smallest area that will not require limitations in device movements.
b) Unless otherwise specified, the area may not fall below this value.
c) It includes the necessary safety clearances (caution: national regulations may devi-
ate from this value);
d) It includes the service areas for the unit;
e) The required areas for unimpeded examination and operational processes, as well
as the footprint required for the control cabinets are not taken into account;
f) Illustration: In the overhead views in this PG, the technically possible area is repre-
sented by a dot and dash line rectangle.
Fig. 2:
Orientation points
Points belonging to system components to which reference is made to each other or to
which reference is made in the room when positioning system parts.
Illustration in the drawings:
8 General Information
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 8 of 130
Fig. 3:
Fixpoints
Clearly designated points on system components, installation ceiling, walls or floors at
which cable outlets are located.
Illustration in the drawings: circle with letter / number combination.
Fig. 4:
The cable lengths determine the maximum fixpoint distances, and thus the maximum
distances between the individual system components.
Room height
The room height is the clear space measured from the top edge of the finished floor to
the bottom edge of the ceiling substructure (bottom edge of the finished ceiling).
Left, right
Fig. 5: Definition of right, left ...
Abbreviations Used 0
Head side Foot side
Left side
Right side
Generator = Angio Generator M or POLYDOROS A100
Patient table = Represents all variants of the AXIOM Artis patient table
DCS = Display Ceiling Suspension
Display / TFT monitor = Flat screen
FD = Flat panel detector
DDIS = Data Display
EPS = Emergency Power Supply
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
General Information 9
Page 9 of 130
Additional Information for Detailed Planning 0
PG: DCS
AXA4-700.891.01...
PG: Klver Cooling Unit
RA71-020.891.01...
Measuring station See the component PG
PG: Siemens Remote Services (SRS)
TD00-000.891.01...
PG: DICOM
TD00-000.891.02...
PG: AXIOM Artis emergency power supplies
AXA4-770.891.02...
PG: Ultrasound Integration
AXA4-810.891.01...
PG: Multi-modality Viewing
AXA4-100.891.14...
PG: Monitor Trolley with Display
AX00-000.891.01...
PG: Voice Control
AXA4-100.891.15...
10 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 10 of 130
2- 2Room Planning
General Information 0
Product-specific Information 0
Plan the control room at the foot end of the patient table (optimum visual contact to the
examination room).
Plan the size and location of the radiation protective window so that the examination
room can be clearly viewed from the control room.
Plan the entrance area as shown.
Plan the equipment room to the left of the examination room.
If possible, do not plan the generator and cooling unit in the examination room (because
of noise and heat generation).
OR patient table (option)
When using the OR table for surgical interventions, plan an on-site UPS. For further
info, see Room Planning > Patient Table
Requirements for Lighting per DIN 6868-57 0
According to DIN 6868-57 (the international standard is still in preparation) the lighting in
rooms where diagnosis is performed using image display devices (monitors) must meet the
following requirements:
Adjustable, glare-free and reproducible setting of lighting (e.g. dimmer with scale)
No reflections from windows, lamps and viewing boxes when the monitors are in their
standard operating position.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 11
Page 11 of 130
Room Size 2.1
Recommendation 0
Fig. 6: Room Plan
Pos. 1 Cable cabinet (option)
Pos. 2 SC1 and SC2 system control cabinets
Pos. 3 Generator
Pos. 4 Cooling unit
Pos. 5 Examination room
Pos. 6 DCS (Option)
Pos. 7 Patient table
Pos. 8 Equipment room
Pos. 9 Floor stand
Pos. 10 Control room
Pos. 11 Hardcopy
Pos. 12 Image system
Pos. 13 Control console
Pos. 14 Measuring station
*1 Image system in the control room (standard), optionally in the equipment room (must be stated
in the order).
*2 2nd control cabinet (SC2) only with the OR patient table
12 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 12 of 130
System with DCS Option 2.2
Instead of the DCS, a monitor trolley can be used, see PG: Monitor Trolley with Display
Top-down View of System without the MULTISPACE.F Option 0
Fig. 7: Top-down view of system without the MULTISPACE.F option
Pos. 1 Head-end/left position rotation range (motorized movement)
Pos. 2 Floor stand in the left position.
Pos. 3 Orientation point/isocenter for floor; stand in the head-end position
Pos. 4 Isocenter in the left position
Pos. 5 Orientation point / floor fixpoint; patient table
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 13
Page 13 of 130
NOTE If the room size permits, the DCS should be shifted one ceil-
ing grid to the left to enable unimpeded turning behind the
table.

Top-down View of System with MULTISPACE.F Option 0
The minimum room width increases due to the two additional working positions
(*1/Fig. 8 / p. 14).
*1 Dimensions without brackets Table rotation with the tabletop fully extended is not restricted.
Dimensions in brackets Table rotation with the tabletop fully extended is restricted.
*2 Dimensions without brackets for Peri, Tilt and OR tables (including 500 mm safety distance to
the wall)
Dimensions in brackets for the basic table
14 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 14 of 130
Fig. 8: Top-down view of system with MULTISPACE.F option
Pos. 1 Head-end/left position rotation range (motorized movement)
Pos. 2 Floor stand in the left position.
Pos. 3 Orientation point/isocenter for floor; stand in the head-end position
Pos. 4 Isocenter in the left position
Pos. 5 Orientation point / floor fixpoint; patient table
*1 Dimensions without brackets Table rotation with the tabletop fully extended is not restricted.
Dimensions in brackets Table rotation with the tabletop fully extended is restricted.
*2 Dimensions without brackets for Peri, Tilt and OR tables (including 500 mm safety distance to
the wall)
Dimensions in brackets for the basic table
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 15
Page 15 of 130
NOTE If the room size permits, the DCS should be shifted one ceil-
ing grid to the left to enable unimpeded turning behind the
table.

16 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 16 of 130
System with a second DCS Option 2.3
In addition to the existing DCS (1st DCS), in the future it will be possible to operate a sec-
ond, optional DCS.
Note the following for planning:
For new plan-
ning:
The 1st DCS (max. 8 TFT monitors) should be planned longitudinally
to the table.
The 2nd DCS (max. 3 TFT monitors) should be planned transversely
to the table.
For a retrofit: The 1st DCS (max. 8 TFT monitors), if installed transversely to the
table, should be planned longitudinally to the table.
If already installed longitudinally, nothing changes.
The 2nd DCS (max. 3 TFT monitors) should be planned transversely
to the table, as with new planning.
The following
applies:
1. DCS longitudinally, 2nd DCS transversely to the table
Limitation for 2nd
DCS:
A max. of only 3 monitors can be installed. Bypass images cannot be
displayed and data display is not released.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 17
Page 17 of 130
Top-down View of System with a Second DCS 2.4
Fig. 9: Top-down view of system with second DCS
Pos. 1 Cable fixpoint, 1st DCS
Pos. 2 Cable fixpoint, 2nd DCS
Pos. 3 Orientation point/isocenter for floor; stand in the head-end position
Pos. 4 Isocenter in the left position
Pos. 5 Orientation point / floor fixpoint; patient table
For ceiling installation with a second DCS, see Detail Planning > Ceiling Installation with a
second DCS.
*1 Dimensions without
brackets
Table rotation with the tabletop fully extended is not
restricted.
Dimensions in brackets Table rotation with the tabletop fully extended is restricted.
18 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 18 of 130
Additional Work Positions with the MULTISPACE.F Option 0
This option enables manual rotation of the floor stand around the axis of rotation (see
below). For medical applications, there are two new work positions, the right position and
OR position.
The option can be retrofitted.
Fig. 10: Multispace.F
Pos. A System in the right position
Pos. B System in the OR position
Pos. 1 Floor stand rotation axis
*2 Dimensions without
brackets
for Peri, Tilt and OR tables (including 500 mm safety dis-
tance to the wall)
Dimensions in brackets for the basic table
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 19
Page 19 of 130
System: DCS Positioning 2.5
Fig. 11: DCS positioning
Pos. A Version 1: Standard in combination with the MULTISPACE.F option
Pos. B Version 2: only without the MULTISPACE.F option
Variant 1 (standard in conjunction with the MULTISPACE.F option):
For the room plan, see Room Planning > System with the DCS Option.
For ceiling installation, see Installation Preparations > Ceiling Installation.
Variant 2 (without MULTISPACE.F option only):
For the room plan, see Detail Planning > DCS Positioning per Variant 2.
For ceiling installation, see Detail Planning > System Ceiling Installation.
20 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 20 of 130
System: Side View 2.6
Fig. 12: System side view
Pos. 1 Max. unit height
*1 Orientation point/isocenter for floor stand in the head-end position
*2 Admissible room height:
DCS 1/2/3: 2500-3100 mm
DCS 4/6/7: 2900-3100 mm
D1 DCS (Option) (ceiling fixpoint)
P1 Floor stand (ceiling fixpoint)
T1 Patient table (floor fixpoint)
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 21
Page 21 of 130
Planning Notes 2.7
Movement Ranges of the Components 0
When planning non-system components in the examination room, pay attention to the
movement ranges of the system components (risk of collision!).
Fig. 13: Movement ranges of the components
Pos. 1 Floor stand movement range
Pos. 2 DCS movement range
Pos. 3 Patient table movement range (foot end)
Pos. 4 Patient table movement range (head end)
22 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 22 of 130
NOTE If the room size permits, the DCS should be shifted one ceil-
ing grid to the left to enable unimpeded turning behind the
table.

Max. admissible Floor Unevenness 0
The maximum admissible floor unevenness of the base floor in the cross-hatched area is
8 mm.
The cross-hatched area represents the rotation area of the stand and the movement range
of the C-Arm.
Fig. 14: Max. admissible floor unevenness
Pos. 1 Wall
Pos. 2 Orientation point/isocenter for floor stand in the head-end position
*1 The MULTISPACE.F option enables manual turning of the stand about rotation
point A. Within the turning range, the stand can lock in at 6 increments; motorized
device movements can then be performed as long as the distance to the wall is at
least 500 mm. Entering the room size into the system configuration during system
start-up ensures that motorized movements will be blocked if this minimum dis-
tance is not met.
The technically possible manual rotation range with the MULTISPACE.F option is
+60/-220.
With a specified room width of 5930 mm, the rotation range is limited by the room
with to -110. For medical applications however, this is of no importance.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 23
Page 23 of 130
*1 In the specified room plan (Fig. 13 / p. 21), the dashed range is intersected by the
wall. If the wall extends further to the left, the dashed range has to be taken into
account accordingly.
24 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 24 of 130
Floor Stand: Side View 2.8
Fig. 15: Floor stand: side view / A: with 20 x 20 flat panel detector / B: with 30 x 40 flat panel detector
Pos. 1 Floor stand in the head-end position.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 25
Page 25 of 130
Floor Stand: Side View 2.9
with Image Intensifier 0
Fig. 16: Floor stand: side view with image intensifier
Pos. 1 Floor stand in the head-end position
*1 190 - 425 mm with 40 cm I.I.
26 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 26 of 130
Floor Stand: Top-down View of dFC/FC/FA/dFA 2.10
Fig. 17: Floor Stand: Top-down View / A: dFC/FC/FA / B: dFA
Pos. 1 Head-end/left position rotation range (motorized movement)
Pos. 2 P1 cable fixpoint on the ceiling
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 27
Page 27 of 130
Pos. 3 Orientation point / isocenter, head-end position
Pos. 4 Isocenter, left position
Pos. 5 Rotation axes
For additional manual rotation range with the MULTISPACE.F option, see Room Planning
> Planning Notes.
28 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 28 of 130
Patient table 2.11
Versions 0
There are 4 different versions of the Artis patient table that can be shipped:
1. Basic Table
2. Peri table (like the basic table with additional motorized longitudinal movement of the
tabletop)
3. Tilting table (like the Peri table with an additional tilting function in longitudinal direction)
4. OR table (like the tilting table with an additional tilting function in transverse direction)
The Artis patient tables all have the same exterior dimensions.
Notes regarding the OR table 0
An additional control cabinet (SC2) is shipped with the OR table. The cabinet primarily
contains the motor controller. Unlike other Artis patient tables, the motor controller can-
not be installed in the table base, as this would limit the tilting and canting movement
functions..
The OR table is splash-proof (IPX4 according to IEC 60 601-2-46).
Use in the operating room
If the table is to be used for surgical interventions, according to IEC 60 601-2-46 it also
has to be able to operate even in the event of a power failure. In this case, system con-
trol cabinet SC1 has to be connected to an on-site uninterruptible power supply
(UPS) . Since all system components, with the exception of the generator, are supplied
power via the control cabinet, the units, image system, etc. remain operational even in
the event of a power failure. For detailed information on the UPS, see PG Axiom Artis
emergency power supplies, print no. AXA4-770.891.02...
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 29
Page 29 of 130
Views 0
Fig. 18: Views of patient table
1 = View x
2 = Card tabletop
3 = Basic table / Peri table (no tilting)
30 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 30 of 130
*1 Power outlet (option)
See the on-site electrical installation -> on-site power cables
*2 Panel for syringe connection
*3 Panel with nipple for compressed air connection
*4 Accessory rails
*5 Longitudinal table tilt (option)
*6 Transverse table tilt (option)
*7 Table Lift
*8 Longitudinal table movement
*9 Transverse table movement
*10 Table rotation range
T1 Patient table, floor fixpoint / orientation point / center of rotation
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 31
Page 31 of 130
Positioning of Cabinets and Components 2.12
Fig. 19: Arrangement of cabinets and components / A=recommendation 1, B=recommendation 2
Pos. 1 Generator cabinet
Pos. 2 Cable cabinet (option)
Pos. 3 System control cabinet #1
Pos. 4 System control cabinet #2 (only with OR pat. table)
Pos. 5 Cooling unit for tube unit
Recommendation 1:
Generator (PU1), system control cabinets (SC1/SC2), and cooling unit (CU1) are in the
equipment room (due to noise and heat generation).
Recommendation 2:
Generator (PU1) and system control cabinets (SC1/SC2) are in the examination room,
cooling unit (CU1) is in the equipment room.
NOTE Note the heat and noise generation of the generator (PU1).

Image system (IS):
in the control room (standard). It may be placed in the equipment room only if specified
in the order.
Take note of the heat dissipation and temperature ranges of the cabinets and compo-
nents (see Chapter 5). If necessary, air condition the equipment room.
Systems with flat panel detector: The maximum permitted height difference between
the detector and SC1 control cabinet is 10 m.
32 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 32 of 130
The cabinets can be set up as shown. The following must be observed:
- The cabinets may only be positioned apart from one another or at a corner at the
locations indicated by the arrows. Here, take note of the System Connections Cable
List > Overview of System Connections.
- When positioning at a corner, maintain a minimum 40 mm distance to the next cabi-
net (necessary to open the cabinet doors).
- The PU1 and cable cabinet can also be positioned to the right of the SC1/SC2.
- For additional information, see (Generator / p. 91) and Detail Planning (System Con-
trol Cabinets #1 / #2 / p. 94).
Cable cabinet (option)
- The cable cabinet is required if excessive cable lengths cannot be housed in any
other manner (e.g., under computer flooring). It has the same dimensions as the gen-
erator cabinet. For cable routing from the top left/right, see (System Connections >
Notes regarding Laying Cables) into the cabinet base from below and from all sides
(except from the front) is possible.
- If you require a cable cabinet, mark it in the checklist sent to you by Logistics. The
cable cabinet is provided free of charge.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 33
Page 33 of 130
Control Room 2.13
Fig. 20: Control room
Pos. 1 Hardcopy
Pos. 2 Image system
Pos. 3 System control console
Pos. 4 Container (if applicable, obtain locally)
Pos. 5 Measuring station
Pos. 6 Option: Multi-Modality Viewing Container (not shown)
Plan the control room at the foot end of the examination room.
Operating console and a second display (not shown; Detail Planning > Second Data
Display (Option).
Control modules (option), ECC (option)
- The control modules for the floor stand, collimator, and patient table are not suited for
freestanding installation. The modules have to be left in the console. The cutout is to
be created on-site by a cabinet maker with a router (for details see Detailed Planning
> Tabletop cutout for control modules and ECC)
- An emergency Stop button is shipped in conjunction with the control modules (not
with the ECC). It has to be installed within reach of the operator.
Position components near the control room distributor (see (System Connections)
(Control Room Details).
Plan the image system in the control room (standard).
It may be placed in the equipment room only if specified in the order.
For the Multi Modality Viewing Container (option), see PG AXA4-100.891.14...
34 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 34 of 130
Fig. 21: Control room
Pos. 1 17" color display for DVD recorder
Pos. 2 Remote Power Archive Unit (RPAU)
Pos. 3 System Live display
Pos. 4 Reference display
Pos. 5 Emergency Stop Switch
Pos. 6 Image system
Pos. 7 UPS
Pos. 8 Control room distributor
Pos. 9 2nd footswitch
Pos. 10 DVD recorder
Pos. 11 Container (obtain locally)
Pos. 12 Control console
Pos. 13 Keyboard + mouse
Pos. 14 Control modules
Pos. 15 ECC
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 35
Page 35 of 130
For control room distributor details, see Detail Planning > (Control Room Distributor
(BTEE) / p. 101).
*1 Option
*2 Image system in the control room = standard, optionally in the equipment
room; must be stated in the order; for details see Detail Planning > Image
System.
*3 Plan the UPS (option) for the image system in the immediate proximity of
the image system. A minimum distance of 25 mm on all sides is required
for air circulation.
*4 The RPAU is required if the image system is set up outside the control
room.
*5 Emergency Stop Switch
36 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 36 of 130
Static Requirements 2.14
Floor Stand 0
Fig. 22: Floor stand installation plate
Pos. A Installation plate
Numbered holes 1-7 for installation directly on the floor; other holes are spare holes.
This maximum value does not occur simultaneously at all mounting points. The tensile
forces depend on the working position and system movement.
The installation plate is anchored in the reinforced concrete with 7 Hilti heavy-duty anchors
bolts.
Minimum concrete quality: C20/25
Max. tensile force:
F1-F7 3.9 kN
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 37
Page 37 of 130
Floor Stand Center of Gravity
Fig. 23: Floor stand center of gravity
Pos. A Installation plate
Point load (stand + installation plate) = 6.6 kN
DCS 0
Vertical ceiling load, Fy
max
:
*1 Range of point load center of gravity from head (N) in the Peri position (P).
*2 Additional point load movement range with the MULTISPACE.F option (option can
be retrofitted)
*3 Orientation point/isocenter for floor stand in the head-end position
38 Room Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 38 of 130
Max. 5.4 kN per attachment point( = 2 screws; the screws can be under differing loads,
max. 4.2 kN)
The dynamic load is exerted on each attachment point, since it is a single moving load.
For additional information see PG AXA4-700.891.01...
Patient table 0
The maximum extraction forces occur with rotated table (+/- 45) with fully extended table-
top at the head-end. The maximum extraction forces were determined with a patient weight
of 250 kg and table accessories weighing 40 kg.
The installation plate is anchored in the reinforced concrete with 4 Hilti heavy-duty anchors.
Minimum concrete quality: C20/25
Foot end load per attachment point: Max. tensile force: 4.5 kN
NOTE With the basic table, the max. admissible patient weight is
250 kg. With the other tables, it is 200 kg.

Center of gravity of the patient table
The movement of the center of gravity during the rotation of the table was determined under
the following conditions:
Tabletop completely extended at the head-end.
Tabletop extended to the right to the end-stop.
Tabletop not tilted.
Tabletop loaded with a patient weight of 250 kg.
Table accessories weighing 40 kg hooked into the right accessory rail.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Room Planning 39
Page 39 of 130
Fig. 24: Center of gravity of the patient table
1 = Movement of center of gravity
2 = Center of gravity with table rotated 120
3 = Orientation point / center of rotation
4 = Center of gravity with table rotated -120
5 = Center of gravity with table in 0 position
*1 A point load of max. 8 kN is exerted on the center of gravity
40 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 40 of 130
3- 3Installation Preparations
General Information 0
Required Aids 0
Transport castor set, Part No. 11 53 654
If the system is installed outside of Europe, the transport castor set, if not already avail-
able, must be ordered in advance.
Installation template, Part No. 65 72 627 G144E
for aligning the installation plates of the floor stand and patient table
- Within Europe, the template can be borrowed from the Hegele Company.
Contact: Tel.: +49 / (0)9191-72 05 610
e-mail: juergen.hoeflinger@hegele.de
Spacer gauge, Part No. 70 004 422 X2278,
to set the correct distance of the DCS longitudinal rails
Floor Stand 0
The pre-installation parts are part of the pre-installation shipment.
The pre-installation parts include the installation plate, along with the installation materi-
als and the ceiling outlet (Detail Planning > Floor Stand Ceiling Outlet).
Preinstallation in Computer Flooring
Recommendation: Floor stand installation plate on filled concrete or on the on-site sub-
structure.
Patient Table 0
The pre-installation parts are part of the pre-installation shipment.
The pre-installation parts include the installation plate and the mounting materials.
Preinstallation in computer flooring
Recommendation: Floor stand installation plate on filled concrete or on the on-site sub-
structure.
Panels are present on the foot end of the table for (see Room Planning > Views)
- Syringe connection
- Compressed air connection
- Power outlet (option)
Injector Floor Outlet Option 0
see Installation Preparations > Injector Floor Outlet Option
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 41
Page 41 of 130
DCS (Option) 0
The pre-installation parts are part of the pre-installation shipment.
The pre-installation parts include the longitudinal rails and the installation materials.
Transverse mounted ceiling profiles (installation ceiling) are the prerequisite for install-
ing the DCS longitudinal rails. Grid spacing for ceiling mounting is max. 675 mm.
Control Room Distributor 0
The control room distributor is positioned in the control room, either under the operat-
ing console (option) or on the wall. For details, see Detail Planning > Control Room Dis-
tributor (BTEE).
If available, plan the second footswitch and/or control modules (floor stand, patient
table) in the control room such that, when activated, visual and acoustic contact is
maintained with personnel, the patient, and the injector.
DVD Recorder + 17" Color Display (Option) 0
When setting up the DVD recorder, make sure there is good ventilation. The clear
space to walls from stationary fixtures or other components must be at least 3 cm.
Reference Display (Option) 0
Located in the DCS (standard) and also possibly in the control room (Room Planning >
Control Room).
Second Data Display (Option) 0
Positioned in the control room or examination room on the wall or on a console.
For details, see Detail Planning > Second Data Display (Option).
Control Cabinets 0
For floor and wall anchoring as well as cable routing, see Detail Planning >
(Generator / p. 91) and (System Control Cabinets #1 / #2 / p. 94).
Store excess cable lengths in the cable cabinet (option), under computer flooring or in
cable ducts, etc. (System Connections > Notes regarding Laying Cables).
Cooling System 0
For additional information, see the Klver Cooling Unit PG, RA71-020.891.01...
42 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 42 of 130
Lower Body Radiation Shield (Option) 0
The lower body radiation shield is installed on the left or the right of the table.
Upper Body Radiation Shield, Surgery Lamp, Injector (Option) 0
1. Overview
2. Upper Body Radiation Shield
2 versions can be shipped:
- Upper body radiation shield with fixed installation
- Movable upper body radiation shield
All mounting parts are included in the shipment. For ordering, see the applicable SIR
PM.
3. Surgery Lamp (Option)
For electrical connection, see Installation Preparations > On-site Power Cable
4. Injector (Option)
There are three ways to install the injector rack mount unit. For details, see Detail Plan-
ning > Injector Rack Mount Unit (Option).
Wireless Footswitch (Option) 0
The "wireless footswitch" is comprised of the following components:
Footswitch
Released Accessories
Ceiling column with fixed installation
(For Dimensional Drawing, see Detail Planning> Fixed
Upper Body Radiation Shield, Surgery Lamp; for posi-
tioning, see Installation Preparations > DCS Version 1
with Fixed Upper Body Radiation Shield (Option), Detail
Planning > Ceiling Installation with Fixed Upper Body
Radiation Shield (Option))
Upper body radiation shield or injector
stand
or
Upper body radiation shield and surgery
light
or
Ceiling column installed on a carriage
(For Dimensional Drawing, see Detail Planning > Mov-
able Upper Body Radiation Shield, Surgery Lamp
(Option); for positioning, see Installation Preparations >
Ceiling Installation, Detail Planning > System Ceiling
Installation)
Upper body radiation shield and/or sur-
gery light
Second carriage for injector stand pos-
sible (separate Part No.)
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 43
Page 43 of 130
Charging unit for footswitch, consisting of: Wall holder for charging cable (7 m);
Plug-in power supply with cable (2 m).
Notes for Planning:
Plan the wall holder in proximity of the patient table in the examination room (max. 5 m
from the patient table).
Attach with screws/anchors or with (adhesive) Velcro tape.
All mounting hardware is included in the shipment.
Weight of wall holder: < 1 kg.
Power consumption: < 10 W.
Power outlet for the charging unit (no fuse protection in the Siemens system).
The outlet always must be live to charge the footswitch battery overnight.
Wall holders and footswitches may not be installed or used in the control room.
44 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 44 of 130
Component Installation 3.1
Floor Mounting 0
Floor Stand/Patient Table
The two installation plates for the stand and the patient table must be installed on solid sur-
face with sufficient load capacity. Cut out the existing floor covering. If applicable, material
that is not capable of handling the load capacity in the area of the installation plates must
be replaced with filled concrete.
Hilti heavy-duty anchors are included for installation of the installation plates:
Longer heavy-duty anchor bolts are available from the Hilti Company on request.
If needed, the installation plates can also be secured through the ceiling of the room
below using M12 threaded rods, min. hardness rating 8.8 according to the ISO Norm
(obtain the threaded rods, etc. on site).
Fig. 25: Floor stand/patient table
Pos. 1 Floor stand support base plate
Pos. 2 Floor stand installation plate
Pos. 3 Orientation point/isocenter for floor stand in the head-end position
Pos. 4 Patient table installation plate
Pos. 5 Patient table orientation point
*1 Patient table cable lead-in:
with installation directly on solid concrete, lead in the cables through a break in
the ceiling from the room below (see Installation Preparations > Patient Table).
with installation on filled concrete, through a cable channel (see Installation
Preparations > Patient Table).
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 45
Page 45 of 130
Installation directly on Solid Concrete
Floor Stand
Fig. 26: Floor stand
Pos. 1 Mounting points for floor stand
Pos. 2 Orientation point/isocenter for floor stand in the head-end position
Pos. 3 Insulation parts
46 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 46 of 130
Pos. 4 Solid concrete
Pos. 5 Installation plate
Pos. 6 Support base plate
Pos. 7 Insulation plate
Installation plate with 13 holes ( 25 mm):
Anchored directly in the concrete with 7 Hilti HSL-3 M12/50 anchors; 7 evenly distrib-
uted holes should be used (see Room Planning > Static Requirements).
No more than two holes may remain open between the attachment points.
Patient Table
*1 Hilti HSL-3 M12/50 anchors (7 included in the shipment)
*2 Floor anchoring with threaded rods through the ceiling possible (threaded rods must
be purchased locally)
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 47
Page 47 of 130
Fig. 27: Patient table
Pos. 1 Head end
Pos. 2 Installation plate
Pos. 3 Solid concrete
Insulation parts (insulation plate, etc.) not shown.
*1 Anchored with 4 Hilti HSL-3 M12/25 anchors
*2 Area for cable inlet in table base
*3 Opening in the installation plate
*4 Cable lead-in through ceiling opening from the room below
*5 Patient table orientation point
48 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 48 of 130
Installation on Filled Concrete
Floor Stand
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 49
Page 49 of 130
Fig. 28: Floor stand
Pos. 1 Mounting points for floor stand
Pos. 2 Size of the concrete filling
Pos. 3 Orientation point/isocenter for floor stand in the head-end position
Pos. 4 Insulation parts
Pos. 5 Installation plate
Pos. 6 Support base plate
Pos. 7 Insulation plate
Pos. 8 Solid concrete
Installation plate with 13 holes ( 25 mm):
Anchored on filled concrete with 7 Hilti HSL-3-G M12/100 anchors; 7 even-distributed
holes should be used (see Room Planning > Static Requirements).
No more than two holes may remain open between two attachment points.
*1 Hilti HSL-3-G M12/100 anchors (7 included in the shipment)
*2 Floor anchoring with threaded rods through the ceiling possible (threaded rods must
be purchased locally)
50 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 50 of 130
Patient Table
Fig. 29: Floor stand
Pos. 1 Cable duct, e.g. 200 x 70 mm
Pos. 2 Head end
Pos. 3 Area of the concrete filling
Pos. 4 Self-leveling grout
Pos. 5 Insulation
Pos. 6 Filled concrete
Pos. 7 Installation plate
Pos. 8 Solid concrete
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 51
Page 51 of 130
Insulation parts (insulation plate, etc.) not shown.
Ceiling Installation 0
DCS Version 1 with Movable Upper Body Radiation Shield (Option)
Recommended ceiling grid: 675 mm
*1 Anchored with 4 Hilti HSL-3 M12/100 anchors
*2 Area for cable inlet in table base; cable routing via cable duct or opening in ceiling from
room below.
When routing via cable duct: To ensure the cable is not bent severely at the table inlet,
plan only cable ducts with a minimum height of 70 mm.
*3 Opening in the installation plate
*4 Patient table orientation point
52 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 52 of 130
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 53
Page 53 of 130
Fig. 30: DCS version 1 with movable upper body radiation shield (option)
Pos. 1 Grid spacing
Pos. 2 Do not plan any lighting components, ventilation outlets, sprinkler elements, etc. between the ceiling rails.
Pos. 3 Radiation shield
Pos. 4 DCS
NOTE If the room depth permits it, the DCS should be moved one
ceiling grid to the left to make unrestricted pivoting behind
the table possible.

DCS Version 1 with Fixed Upper Body Radiation Shield (Option)
Not recommended in conjunction with the MULTISPACE.F option
*1 Orientation point/isocenter for floor stand in the head-end position
*2 Floor stand ceiling outlet (see Detail Planning > Floor Stand Ceiling Outlet)
*3 DCS ceiling outlet
*4 observe the maximum admissible rail overhang.
*5 The ceiling rails (option) for the radiation shield, surgery lamp, injector stand (see
Detail Planning > Movable Upper Body Radiation Shield, Surgery Lamp (option));
length when shipped: 4 m, can be shortened.
IN1 Injector stand installed on the injector ceiling column in the radiation shield rails
(option).
SU Surgery lamp (option), (see Installation Preparations > On-site Power Cables,
Detail Planning > Movable Upper Body Radiation Shield, Surgery Lamp (Option).
TR1 Control console cart (option) (see Detail Planning > Control Console Cart
(Option))
54 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 54 of 130
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 55
Page 55 of 130
Fig. 31: DCS version 1 with fixed upper body radiation shield (option)
Pos. 1 Do not plan any lighting components, ventilation outlets, sprinkler elements, etc. between the ceiling rails.
Pos. 2 Radiation shield installation plate
Pos. 3 DCS
NOTE If the room depth permits it, the DCS should be moved one
ceiling grid to the left to make unrestricted pivoting behind
the table possible.

*1 Orientation point/isocenter for floor stand in the head-end position
*2 Floor stand ceiling outlet (see Detail Planning > Floor Stand Ceiling Outlet)
*3 DCS ceiling outlet
*4 Installation plate (option, see Detail Planning > Fixed Upper Body Radiation
Shield, Surgery Lamp (Option)) for
Radiation Shield and Surgery Lamp
or Injector Stand
*5 With a smaller ceiling grid, move the installation plate to the side until it is centered
to the ceiling grid.
IN2 Injector head with fixed installation on the ceiling (option)
SU Surgery lamp (option) (see Installation Preparations > On-site Power Cables,
Detail Planning > Fixed Upper Body Radiation Shield, Surgery Lamp (Option)).
TR1 Control Console Cart (option)
56 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 56 of 130
On-site Electrical Installation 3.2
The detailed regulations regarding electrical installations must be observed.
In Germany, the most important standards used are in the series VDE 0100 and VDE
0100-710; in other countries, the applicable national regulations.
For power line connection voltages, see (Electrical Data / p. 87).
Notes regarding the recommendations on the following pages for electrical instal-
lation in accordance with DIN VDE 0100-710 0
RCD Ground Fault Circuit Interrupters
Only use ground fault circuit interrupters for alternating and pulsed DC fault currents,
with no surge current, with I
N
= 30 mA.
An RCD ground fault circuit interrupter cannot be used in power networks without an N
cable.
RCD ground fault circuit interrupter for system control cabinet (SC1):
I
N
= 40 A/ I = 30 mA
RCD ground fault circuit interrupter for generator: According to DIN EN 50178 clas-
sification VDE 0160, "Ausrstung von Starkstromanlagen mit elektronischen Betrieb-
smitteln" (Equipping of high-voltage systems with electrical resources), the following FI
circuit breakers are to be used exclusively.
Line voltage RCD Pre-fusing
for U
N
= 3 400/415 V: I
N
= 63A
I = 30 mA
Purchased via electrical wholesaler:
Order no. 5SM3 346-4 allstrom
Purchased via SPH (Med depart-
ment: Part no. 49 54 470 Y7933
(Width of the RCD ground fault cir-
cuit interrupter is 72 mm = 4TE,
mounting on a standard rail)
63 A slow-blow
for U
N
greater than 3
415 V:
U
N
= 500V
I
N
= 125A
I = 30 mA
Purchased via SPH (Med depart-
ment):
Part no. 51 41,168 Y7933
63 A slow-blow
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 57
Page 57 of 130
On/Off switch (with pilot light)
Provide an on-off switch for the system. Preferably, this on/off switch should be located in
the equipment room (if configured). The installation height is 180cm.
Emergency Off switch (with lock)
For fast system shutdown in hazardous situations, at least one emergency off switch (with
lock) is to be provided in the examination room, control room, and equipment room. It
should be positioned 1.8 m high is such a way that it is easy to reach but without the pos-
sibility of accidental activation.
Recommendation for Application Group 1 0
Electrical installation on site per DIN VDE 0100-710
Fig. 32: Electrical installation: Recommendation application group 1
A = Suggestion for room distributor
B = Power supply cable for X-ray
C = 5x according to calculation
1 Potential ground wire to external conductive parts
2 Power cable to fixed or movable equipment
58 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 58 of 130
NOTE The short circuit pre-fusing values apply to the SIEMENS
ground fault circuit interrupters only

NOTE If using a system UPS, the specifications in the Emergency
Power Supply PG must be observed for the emergency OFF
circuit.

Recommendation for Application Group 2 0
Electrical installation on site per DIN VDE 0100-710
3 Power cable to fixed or movable equipment, e.g., developer machine
4 Ground Fault Circuit Interrupter
4a Ground fault circuit interrupter for system control cabinet
4b Ground fault circuit interrupter for generator
5 System breaker
6 Isolation transformer with overload monitoring conforming to DIN VDE
0100-710, Section 710.512.1.6.2 (output power 3.15 - 8 kVA, isolation test volt-
age 4 kV).
7 For MMV connection, see PG: AXA4-100.891.14... (option)
EAT On/Off switch with pilot lamp for X-ray system
AT1 Emergency off button in examination room
AT2 Emergency off button in control room
AT3 Emergency off button in equipment room
[]
Figures are free cable lengths in m
*1 Surgery light connection (115 V or 230 V ) (option), see Installation Prepa-
rations > On-site Electrical Installation > On-site Power Cables.
*2 Table outlet connection (option), see Installation Preparations > On-site Elec-
trical Installation > On-site Power Cables > Table Outlet.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 59
Page 59 of 130
Fig. 33: Electrical installation: Recommendation for Application Group 2
Pos. 1 Power supply
Pos. 2 Suggestion for room distributor
Pos. 3 Emergency Power Supply SV
Pos. 4 Second cable
Pos. 5 First cable
Pos. 6 Power supply cable for X-ray
Pos. 7 5x per the calculation
*1 Surgery light connection (115 V or 230 V ) (option), see Installation Preparations > On-site Elec-
trical Installation > On-site Power Cables.
*2 Table outlet connection (option), see Installation Preparations > On-site Electrical Installation >
On-site Power Cables > Table Outlet.
*3 Required only for the CATHCOR (not for Sensis).
1 Voltage monitoring and switching device according to VDE 0100-710
2 Isolation transformer with overload monitoring conforming to DIN
VDE 0100-710, Section 710.512.1.6.2 (output power 3.15 - 8 kVA,
isolation test voltage 4 kV).
3 Isolation monitoring device
60 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 60 of 130
NOTE The short circuit pre-fusing values apply to the SIEMENS
ground fault circuit interrupters only

NOTE If using a system UPS, the specifications in the Emergency
Power Supply PG must be observed for the emergency OFF
circuit.

On-site Power Cables 0
A maximum of four on-site power cables are required:
Power cables to the system control cabinet (SC1)
- Power cable, 5x 16 mm
2
.
- The connection terminals are designed for a maximum of 16 mm
2
.
4 Report and test combination
5 Potential ground wire to external conductive parts
6 Power cable to fixed or movable equipment
7 Power to fixed or movable equipment, e.g., developer machine
8 Ground Fault Circuit Interrupter
8a Ground fault interrupter switch for the system control cabinet, see the
note (Installation Preparations > On-site Electrical Installation)
8b Ground fault interrupter switch for the generator, see the note (Instal-
lation Preparations > On-site Electrical Installation)
8c Pre-fusing for the generator, see (Installation Preparations > On-site
Electrical Installation)
9 System breaker
10 4-socket connection strip for AXIOM Sensis (option)
11 Gnd pin socket
12 For the MMV connection, see PG: AXA4-100.891.14... (option)
EAT On/Off switch with pilot lamp for X-ray system
AT1 Emergency off button in examination room
AT2 Emergency off button in control room
AT3 Emergency off button in equipment room
D1 ECG display option in DCS
[]
Figures are free cable lengths in m
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 61
Page 61 of 130
Generator Power Cable (PU1)
- Power cable 5x per the calculation. Here, take note of the internal line resistance:
a) Measure the internal power line resistance, R
i
, at the sub-distributor with an internal
line resistance meter.
b) Size the power cable so that the max. admissible R
imax
(see table) is not exceeded.
Measured internal power line resistance plus resistance of the power cable R
imax
.
* Resistance value in Ohm at U
N
, -15%
** Resistance value in Ohm at U
N
, -10%
Resistance values in Ohms at UN, +/- 10%
- Maximum power output for the generator (Angio Generator M or POLYDOROS
100A) is 100 kW. With a larger internal line resistance than is listed in the above table
for 100 kW, the generator power is automatically reduced.
For the X-ray tubes currently being shipped, a max. generator power of 80 kW is suf-
ficient.
- Minimum Ri: 0.02 Ohm
- Max. cable cross section that can be connected: 70 mm
2
.
Angio Generator M
U
N
P
100 kW 80 kW
400 V* 0.10 Ohm 0.14 Ohm
415 V** 0.14 Ohm 0.17 Ohm
440 V** 0.16 Ohm 0.21 Ohm
480 V** 0.20 Ohm 0.27 Ohm
POLYDOROS A100
U
N
P
100 kW 80 kW
380 V 0.08 Ohm 0.10 Ohm
400 V 0.09 Ohm 0.11 Ohm
420 V 0.09 Ohm 0.12 Ohm
440 V 0.10 Ohm 0.14 Ohm
480 V 0.12 Ohm 0.16 Ohm
62 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 62 of 130
Connecting the Surgery Lamp (Option)
Fig. 34: Connecting the surgery lamp (option)
Pos. 1 Room distributor
Pos. 2 Surgery lamp, 1 bulb
Pos. 3 Surgery lamp, 3 bulbs
Surgery lamp: (1 bulb)
Power consumption 50 W
can be connected to 115 V or 230 V (inter-
nal transformer)
Surgery lamp: (3 bulbs)
Power consumption 160 W
can be connected to 115 V to 247 V
(external transformer)
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 63
Page 63 of 130
If necessary, obtain all cables, switches, and relays locally.
Table Power Outlet (Option)
An optional power outlet is available for the patient table.
- If the power outlet was ordered, it has already been installed in the table at the fac-
tory.
- All patient tables are shipped ex factory with the 2 x 1.5 mm
2
power cable pulled in.
Connecting the Table Power Outlet:
in examination rooms according to application group 1 with MMV:
Power supply to the table power outlet via MMV or an external isolation transformer
with overload monitoring (see (Recommendation for Application Group 1 / p. 57)).
in examination rooms according to application group 1 without MMV:
Power supply to the table power outlet via an external isolation transformer with over-
load monitoring (Recommendation for Application Group 1 / p. 57).
in examination rooms according to application group 2:
Regardless of whether an MMV is configured, the connection to the hospital backup
power supply is provided via an isolation transformer with isolation monitoring in accor-
dance with EC 60364-7-710, Section 710.413.1.5 (output power 3.15 - 8 kVA, isolation
test voltage 4 kV). Secondary fusing of the outlet at 115 V: 5 A, for 230 V: 2.5 A(Recom-
mendation for Application Group 2 / p. 58)
*1 For the connection to line voltage, see Installation Preparations > (Recommendation
for Application Group 1 / p. 57), Installation Preparations > (Recommendation for
Application Group 2 / p. 58), *1
*2 The light can be connected:
directly or
via a wall switch (*2a),
an additional footswitch, Part No. 17 41 313 (*2b),
via the potential-free contact of the Z58/M102
to the line voltage. The surgery light is switched on and off with fluoro / exposure via
the potential-free contact of the Z58/M102.
*3 The three-bulb surgery lamp (option) operates via an external transformer. The trans-
former (dimensions L 280 x W 200 x H 160 mm; weight approx. 8 kg) should be
installed near the SC1.
*4 For systems shipped prior to 6/2005, the K4 relay must be planned on site, e.g. in the
room distributor.
64 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 64 of 130
Siemens Remote Services (SRS) 3.3
For detailed information on SIEMENS Remote Services (SRS), see PG
TD00-000.891.01... (on the Intranet under: CS/ForService/ProductInformation/Siemens
Remote Service
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 65
Page 65 of 130
Network 3.4
The image system is equipped with a network card for Fast Ethernet (100 Base T).
Network connection with system switch (in delivery volume)
Fig. 35: Network
66 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 66 of 130
DICOM 3.5
For detailed information on DICOM, see PG TD00-000.891.02...
Can be found on the Intranet under: CS/ForService/ProductInformation/Planning/Gen-
eral...
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Installation Preparations 67
Page 67 of 130
Injector Floor Outlet Option 3.6
Fig. 36: Injector floor outlet (option)
Pos. 1 Patient table installation plate
Pos. 2 Table longitudinal axis
Pos. 3 Area in which the outlet is installed. The outlet must be planned centered to the table longitudinal axis.
Pos. 4 Head end
NOTE An injector cable may not be pulled through the table base.
It is absolutely necessary to route the injector cable via the
floor outlet.

The following manufacturers have been released: 0
Medrad:
Josh Sevick (Cardiovascular Product Manager)
Medrad Inc.
One Medrad Drive
Indianola, PA 15051-0780
jsevick@medrad.com
68 Installation Preparations
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 68 of 130
Tyco:
Pat Dyer
Site Planning Dept.
2111 E. Galbraith Rd.
Cincinnati, Ohio 45237
pat.dyer@tycohealthcare.com
+1 (513) 761-2700 ext.5721
Detailed information on planning / project planning can be obtained from the addresses
indicated
Fig. 37: Medrad floor outlet
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
System Connections 69
Page 69 of 130
4- 4System Connections
General Information 0
All system-specific cables (including the protective conductor) are included in the ship-
ment.
The system cables consist of standard cables and cable wiring harnesses of a fixed
length. They may not be shortened.
Excessive cable lengths can be stored in the cable cabinet (option), cable ducts, under
computer floors, etc.
Notes regarding on-site electrical installation are included (Recommendation for Appli-
cation Group 1).
70 System Connections
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 70 of 130
Overview of System Connections 4.1
Fig. 38: Overview of system connections
Pos. 1 Ethernet
Notes:
RV = Room Distributor
The room distributor and the power cables are not included in the shipment.
The illustration includes the cable cabinet (option).
The wiring harnesses can also be laid to the fixpoints directly, i.e., without routing them
through the cable cabinet. The excess cable lengths must then be stored in another
way (in cable conduits, under computer flooring, etc.).
The option "monitor trolley (fixpoint D2)" is not shown.
For a definition of the fixpoints, see the System Connections > List of Fixpoints.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
System Connections 71
Page 71 of 130
List of Fixpoints 4.2
Maximum Fixpoint Distances and Planning Cable Channel Sizes 0
Wiring
Harness
No.
From
fix-
point
To fix-
point
Cable
channel
cross-sec
tion in
mm2
Con-
duit,
clear
space
in
inches
Mini-
mum
open-
ing in
mm
Maximum fix-
point dis-
tance in m
Comment
1 P1 PU1 780 2 32 16
2a P1 PU1 500 3 42 16 High-voltage cables
2b P1 PU1 500 3 42 16 High-voltage cables
3 P1 SC1 3125 3 70 x 50 15 min. bending radius:
80 mm
4 P1 CU1 2000 2,5 50 30 min. bending radius:
50 mm
5 SC1 CR1 780 3 60 x 35 19 for control room
options (control mod-
ules, footswitches, dis-
play, ECG).
6 SC1 CR1 780 3 55 x 55 19
7 SC1 T1 3125 3 80 x 55 14 skipped with OR tables
8 SC1 SC2 780 2 50 x 25 2
only with OR tables 9a SC2 T1 3125 3 80 x 55 14
9b SC2 T1 3125 3 80 x 55 14
10 SC1 CU1 780 2 35 30
11 SC1 PU1 780 2 35 x 35 5
12 SC1 IS 780 3 55 x 35 19
13a SC1 D1 780 3 50 x 40 19
DCS (Option)
13b IS D1 780 2,5 40 x 25 19
14a SC1 D12 780 3 50 x 40 19
2. DCS (Option)
14b IS D12 780 2,5 40 x 25 19
15 SC1 D2 780 2,5 40 x 25 19
Monitor Trolley
(Option) *
16 IS D2 780 2,5 40 x 25 19
72 System Connections
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 72 of 130
17a IS CR1 780 3 50 x 25 19
only if the image sys-
tem is located outside
of the control room.
17b IS CR1 780 2 25 19
17c IS CR1 780 2 25 19
17d IS CR1 780 2 35 x 15 19
18 SC1 TR1 780 3 60 x 35 16 Control Console Cart
(Option) **
19 IS
Ethernet cable (thick wire or twisted pair)
Ethernet connection
(option), on-site cable
19a CR1 Net-
work
socket
Ethernet cable (included in shipment)
see Installation Prepa-
rations > Network; 5 m
and 30 m included in
shipment
20 SC1 IW 780 3 60 x 35 19
Injector wall connec-
tion (option)
21 SC1 IW 780 3 55 x 55 19
22 CR1 Dis-
play
290 2 30 x 20 8 Second display
(option)
23 CR2 D1 150 2,5 40 x 40 27 Measuring station
(option)
24 CR2 SC1 100 3 70 x 17 27 Measuring station
(option)
25 CR2 T1 120 2 45 x 15 27 Measuring station
(option)
T1 CR1 Ultrasound Integra-
tion option; for details,
see the Ultrasound
PG.
RV PU1 Power cable Generator (Power Unit 1) -> Installation
Preparations > Recommendation for Application Group
1
On-site cables
RV SC1 Power cable System control cabinet -> Installation
Preparations > Recommendation for Application Group
1
On-site cables
RV SU Power cable Surgery Lamp (Option) -> Installation
Preparations > Recommendation for Application Group
1
On-site cables
Wiring
Harness
No.
From
fix-
point
To fix-
point
Cable
channel
cross-sec
tion in
mm2
Con-
duit,
clear
space
in
inches
Mini-
mum
open-
ing in
mm
Maximum fix-
point dis-
tance in m
Comment
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
System Connections 73
Page 73 of 130
List of Fixpoints Used 0
with-
out the
MMV
RV
with-
out
the
MMV
T1
125 1/2 10 28 Table power outlet
option, see Installation
Preparations > Rec-
ommendation for
Application Group 1;
Installation Prepara-
tions > Recommenda-
tion for Application
Group 2; Installation
Preparations > On-site
Power Cables
with
the
MMV
MMV
with
the
MMV
T1
125 1/2 10 28
Wiring
Harness
No.
From
fix-
point
To fix-
point
Cable
channel
cross-sec
tion in
mm2
Con-
duit,
clear
space
in
inches
Mini-
mum
open-
ing in
mm
Maximum fix-
point dis-
tance in m
Comment
* 6 m from the ceiling outlet to the monitor cart
** 6 m from the ceiling outlet to the control console cart
Fixpoint Subsystem Comment
CR1 Control room (X-ray control room) Fixpoint on the bottom of the
control room distributor
CR2 Measuring station (control room, E-medicine)
(option)
Floor fixpoint
CU1 Cooling unit for X-ray tube unit cooling (Cooling
Unit 1)
Floor fixpoint
D1, D12 DCS (Option) Ceiling fixpoint
D2 Monitor Trolley (Option) Ceiling fixpoint
IN1 Injector head on the injector ceiling column in the
radiation shield support arm system (option)
Ceiling fixpoint
IN2 Injector head with stationary installation on the ceil-
ing (option)
Ceiling fixpoint
IS Image System Floor/wall fixpoint
IW Injector wall connection in the examination room
(option)
(Injector Wall Outlet)
Wall fixpoint
74 System Connections
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 74 of 130
P1 Floor stand (Plane 1) Ceiling fixpoint
SC1 System control cabinet #1 (system control) Floor fixpoint
SC2 System control cabinet #2 (only with the Axiom
Artis OR patient table)
Floor fixpoint
PU1 Generator #1 (Power Unit #1) Floor fixpoint
SU Surgery lamp (option) Ceiling fixpoint
T1 Patient table (Table) Floor fixpoint
TR1 Control console cart (trolley) (option) Ceiling fixpoint)
Fixpoint Subsystem Comment
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
System Connections 75
Page 75 of 130
Laying Cables 4.3
Notes:
Lay cables/wiring harnesses separately in conduits or in closed cable channels.
If laying in open cable channels, lay cables separately using metal dividers or a similar
device.
The cable channel depth should be at least 70 mm; if there are cross-overs, it may be
necessary to provide for greater depth.
Calculating the Required Cable Channel Cross Section 0
The total of the cross sections of the cables/wiring harnesses present should apply for all
cable channel/conduit cross sections. The individual cross sections can be taken from the
cable list. The required fill factor are already included in this. If excess cable lengths are to
be stored in the cable channels, this must be taken into account when sizing.
Remarks regarding Laying Cables 0
Laying excess cable lengths:
in the cable cabinet (option; service friendly)
in cable channels (take note of accessibility)
in ceiling/wall boxes (take note of accessibility)
under computer flooring (service friendly)
The following must be observed:
Cable coils are not allowed!
76 System Connections
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 76 of 130
Fig. 41: Routing excess cable length in the false floor
Pos. 1 Meander cable in false floor
Fig. 39: Routing excess cable length in the cable cabinet
Pos. 1 Meander cable in cable cabinet
Fig. 40: Routing excess cable length in the cable
duct
Pos. 1 Meander cable in cable duct
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
System Connections 77
Page 77 of 130
Control Room Details 4.4
Image System in the Control Room (Standard) 0
Fig. 42: Optional image system in the control room (standard)
Pos. 1 Display
Pos. 2 Keyboard
Pos. 3 Mouse
Pos. 4 Ref. display
Pos. 5 Handswitch
Pos. 6 Control modules
Pos. 7 ECC
Pos. 8 Emergency stop
Pos. 9 Footswitch
Pos. 10 DVD recorder
Pos. 11 Image system in the control room
Pos. 12 Control room distributor
78 System Connections
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 78 of 130
Image System optionally in the Equipment Room 0
If the image system is located in the equipment room, the video cables to the monitor, etc.
are routed via the control room distributor.
* Video cables
** Monochrome or color displays can be shipped.
Type of Display max. distance to image system in m
17 color display 7,5
18 color display 3,5
18 monochrome display 3,5
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
System Connections 79
Page 79 of 130
Fig. 43: Image system in the control room
Pos. 1 Remote Power and Archive Unit
Pos. 2 Display
Pos. 3 Keyboard
Pos. 4 Mouse
Pos. 5 Ref. display
Pos. 6 Handswitch
Pos. 7 Control modules
Pos. 8 ECC
Pos. 9 Emergency stop
Pos. 10 Footswitch
Pos. 11 DVD recorder
Pos. 12 Control room distributor
* Monochrome or color displays can be shipped.
80 System Connections
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 80 of 130
Room Light, Radiation Display, Door Contact, EPS 4.5
For room light control, etc., only use flexible cables within the control cabinet (SC1).
Fig. 44: Room Light, Radiation Display, Door Contact, EPS
Pos. 1 System control cabinet
Pos. 2 Room light
Pos. 3 External radiation display
Pos. 4 Potential-free door contact (24 VDC / 20 mA) *1, door closed = contact closed
Pos. 5 Potential-free contact for EPS (24 VDC / 20 mA) *3, emergency power "on" = contact closed
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
System Connections 81
Page 81 of 130
*1 If needed, a switch to block radiation can be installed in series with the door con-
tact.
The switch (24 VDC / 20 mA) must be provided on site.
Control using +24 V from the system control cabinet
Plan the switch so that unintentional operation is not possible.
The switch must be provided with an appropriate symbol (or designation) from
which the function can be recognized.
*2 If the 2 A current load is insufficient, plan an external power relay through which
the room light can be switched on and off.
*3 When emergency power is "on", exposure mode is blocked and only emergency
fluoroscopy is possible.
*4 With systems shipped prior to 6/2005, the k4/K5 relays must be provided on site.
Control of the relay is with 24 V DC (max. 0.2 A). A free-wheeling diode must be
circuited over the relay coil.
SC1 Fixpoint system control cabinet
82 Technical Data
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 82 of 130
5- 5Technical Data
Dimensions, Weights and Heat Dissipation,... 0
Examination Room 0
Fixpoint Sub-system Dimensions (W
x D x H)
[mm]
Weight
[kg]
Heat Dissipa-
tion [kW]
D1 DCS (Option) see the DCS PG
D2 Monitor carriage with display (option) see the PG
P1 Floor stand (with installation plate)
Installation plate
see Room Plan-
ning > Floor
Stand: Side View
See Installation
Preparations >
Installation
directly on Solid
Concrete
< 665
approx.
45
0,2
n.a.
T1
Patient table (incl. installation plate, 22 kg
and table accessories, 40 kg):
Basic table
Peri table
Tilt table
OR table
see Room Plan-
ning > Views
452
482
530
550
0,2
0,2
0,2
0,1
TR1 Control console cart See Detail Plan-
ning > Control
Console Cart
(Option).
approx.
26
n.a.
SU Fixed upper body radiation shield, surgery
lamp (option)
See Detail Planning > Fixed
Upper Body Radiation
Shield, Surgery Lamp
(Option)
n.a.
SU Movable Upper Body Radiation Shield,
Surgery Lamp (Option)
See Detail Planning > Mov-
able Upper Body Radiation
Shield, Surgery Lamp
(Option)
n.a.
IW Injector Wall Connection Box (Option) 324 x 102 x 257 approx.
5
n.a.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Technical Data 83
Page 83 of 130
Equipment Room 0
Control Room 0
Fixpoint Sub-system Dimensions (W x D x
H) [mm]
Weight
[kg]
Heat Dissipation
[kW]
CU1 Cooling Unit (Cooling Unit 1) 479 x 398 x 481 42 2,4
SC1
System Control Cabinet #1:
System with image intensifier
Systems with Flat Panel Detec-
tor
600 x 434 x 2202 235
270
0,9
max. 1.6
SC2 System Control Cabinet #2
(only with the OR table)
600 x 434 x 2202 125 0,2
PU1 Angio Generator M 800 x 434 x 2202 350 1,0
PU1 Polydoros A100 800 x 434 x 2202 300 1,0
n.a. Cable cabinet (option) 800 x 434 x 2202 120 n.a.
Fixpoint Sub-system Dimensions (W x
D x H) [mm]
Weight
[kg]
Heat Dissipation
[kW]
IS Image system 689 x 800 x 720 87 0,7
n.a. UPS for Image System (Option) 170 x 439 x 216 19 0,03
n.a. Remote Power Archive Unit (only
when image system is in equipment
room)
216 x 368 x 222 9 < 0,1
CR1 Control Room Distributor 1054 x 207 x 409 29 0,1
n.a. Keyboard 447 x 157 x 20/55 < 1 0,1
n.a. 17" display
or 17 color display
or 18 color display
or 18 monochrome display
413 x 230 x 413
413 x 230 x 413
413 x 230 x 413
413 x 230 x 413
9,0
9,0
9,0
9,8
< 0,07
< 0,07
< 0,07
< 0,07
n.a. DVD Recorder 214 x 365 x 102 4,6 0,1
n.a. 17" Color Display for DVD Recorder
(Option)
413 x 230 x 413 9,0 < 0,07
n.a. Second Examination Control Con-
sole (ECC) (Option)
370 x 225 x 70/90 approx. 3 n.a.
n.a. Patient Table Control Console
(Option)
91 x 161 x 65/85 < 1 n.a.
84 Technical Data
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 84 of 130
Floor stand control console in the col-
limator control console (option)
216 x 161 x 65/85 < 2 n.a.
n.a. Control console (option)
(height adjustable from 705 to 730
mm)
1392 x 800 x 720 approx.
60
n.a.
D1 Second Data Display (Option) See Detail Planning
> Second Data Dis-
play (Option).
9 n.a.
Fixpoint Sub-system Dimensions (W x
D x H) [mm]
Weight
[kg]
Heat Dissipation
[kW]
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Technical Data 85
Page 85 of 130
Climatic Conditions 5.1
NOTE Observe the limited temperature range in the examination
room as well as in the equipment room (SC1 system control
cabinet) with the systems with the flat panel detector (see *2).

Examination and control
room
Temperature range:
Relative humidity:
10 C... 35C
*1
(recommended tempera-
ture 22 C)
15 C... 30 C
*2
20-75% without condensation
Image System (IS) Temperature range:
Relative humidity:
Max. temperature gradient:
Air flow rate:
Max. noise level:
10 C... 35 C
20-75% without condensation
10 C/h
657 m
3
/h
50 dB(A)
Angio Generator M or
POLYDOROS A100 (PU1)
Temperature range:
Relative humidity:
Max. temperature gradient:
Air flow rate:
Max. noise level:
10 C... 35 C
20-75% without condensation
5 C/h
160 m
3
/h
55 dB(A)
System control cabinet #1
(SC1)
Temperature range:
Relative humidity:
Max. temperature gradient:
Air flow rate:
Max. noise level:
10 C... 35 C
*1
15 C... 30 C
*2
20-75% without condensation
5 C/h
500 m
3
/h
48 dB(A)
System control cabinet #2
(SC2)
Temperature range:
Relative humidity:
Max. temperature gradient:
Air flow rate:
Max. noise level:
10 C... 35 C
20-75% without condensation
5 C/h
n.a.
n.a.
86 Technical Data
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 86 of 130
Cooling unit (CU1)
(for Megalix X-ray tube)
Cooling air:
Air flow:
Max. noise level:
5 C... 30 C (frost-free room)
1100 m3/h
55 dB(A) at 50 Hz, 59 dB(A) at 60 Hz
Stand with flat detector Max. temperature gradient:
Barometric pressure:
Mechanical impact:
Vibrations:
5 C/h
70 kPa... 104 kPa
max. 10 g/ 16 ms
max. 0.1 g/ 10-200 Hz
*1: System with image intensifier
*2: Systems with Flat Panel Detector
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Technical Data 87
Page 87 of 130
Electrical Data 5.2
NOTE If using on-site voltage stabilization, contact Customer Solu-
tions.

Nominal
connec-
tion volt-
age * [V]
+/- 10%
Frequency
[Hz] +/- 1 Hz
Internal
fusing
[A]
Exter-
nal
fus-
ing
[A]
Max.
power
con-
sump-
tion [kVA]
Connection
value ** [kVA]
Angio Generator M
(shipped until
09/2005)
(Power Unit PU1)
3 ph. 400 50/60
63 ***
18 for fluo-
roscopy
160 for
exposure
43,6
3 ph. 415 50 45,3
3 ph. 440 50/60 48,0
3 ph. 480 60 52,4
POLYDOROS A100
(Power Unit PU1)
3 ph. 380
50/60 50
63A
slow-b
low
8 for fluo-
roscopy
160 for
exposure
32,9
3 ph. 400 34,6
3 ph. 420 36,4
3 ph. 440 38,1
3 ph. 480 41,6
System control cabi-
net
(System Control SC1)
3 ph. 380 50/60
35
50

slow-b
low
8,5
23,0
3 ph. 400 50/60 24,2
3 ph. 440 50/60 26,7
3 ph. 480 60 29,1
* Max. permissible voltage between phases (L1, L2, L3) and Gnd: 300 V
** The connection value is calculated using the following formula:
Connection value = 3 x nominal connection voltage x internal fusing
*** Depends on the type of ground fault interrupter, see Installation Prep-
arations > On-site Electrical Installation
88 Technical Data
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 88 of 130
Paint Information 5.3
Primary color Medical White, C610
Combination Color Medical Blue, C750
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Technical Data 89
Page 89 of 130
Transport and Storage 5.4
System
Temperature range: -20 C ... 60 C
Relative humidity: 10 % ... 95% without condensation
Barometric pressure: 50 kPa ... 106 kPa
Mechanical shocks max. 10 g/ 16 ms
max. 25 g/ 6 ms (in original packaging)
Vibrations max. 2 g/ 58-150 Hz
max. 10 g/ 58-150 Hz (in original packaging)
90 Transport and Storage Conditions
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 90 of 130
6- 6Transport and Storage Conditions
Packaging and Transport Routes 0
Largest crate with packaging, weight dFC/FC/FA W 2760 x D 1020 x H 2090 mm, approx. 1200
kg
dFA W 2800 x D 950 x H 2020 mm, approx. 1200
kg
Largest single part with transport car-
riage (min. door opening), weight
dFC/FC/FA W 2500 x D 820 x H 1900 mm, approx. 760
kg
dFA W 2620 x D 820 x H 1880 mm, approx. 760
kg
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 91
Page 91 of 130
7- 7Detail Planning
Generator 0
Fig. 45: Generator
92 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 92 of 130
A = Front View
B = Side View
C = Top-down view
1 = Exhaust air
2 = Cabinet base
3 = Air intake
4 = For service
5 = Cabinet doors, removable
*1 Removable base panels on all sides.
*2 Distance to wall is not required.
*3 When setting up across from one another, the min. distance to the cable cabinet
is 40 mm (required to open the cabinet doors).
*4 Wall mounting is required, because the assemblies can be pivoted out. Secure
the cabinet to the wall with wall anchors and the supplied brackets. Obtain
anchors locally.
If needed, the cabinet can also be secured to the floor with anchors (see next
page).
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 93
Page 93 of 130
Fig. 46: Generator
Pos. A Top-down view of cabinet
Pos. B Top-down view of cabinet base
Pos. C Side view of cabinet base
Pos. D Rear view of cabinet base
Pos. 1 Ventilation
*1 14 mm holes for floor mounting
Obtain anchors locally.
*2 Cable lead-in
To ensure that the power cable can be strain-relieved, it must be lead into the cabinet
base as far as possible on the right (direction of arrow).
The power cable cannot be lead in from the left side.
94 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 94 of 130
System Control Cabinets #1 / #2 7.1
Fig. 47: System control cabinet #1 / #2
A = Front View
B = Side View
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 95
Page 95 of 130
C = Top-down view
1 = Exhaust air
2 = Cabinet base
3 = Air intake
4 = For service
5 = Cabinet doors, removable
*1 Removable base panels on all sides.
*2 Distance to wall is not required.
*3 When setting up across from one another, the min. distance to the cable cabinet
is 40 mm (required to open the cabinet doors).
*4 Wall mounting is required, because the assemblies can be pivoted out. Secure
the cabinet to the wall with wall anchors and the supplied brackets. Obtain
anchors locally.
If needed, the cabinet can also be secured to the floor with anchors (see next
page).
96 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 96 of 130
Fig. 48: System control cabinets #1 / #2
Pos. A Top-down view of cabinet
Pos. B Top-down view of cabinet base
Pos. C Side view of cabinet base
Pos. D Rear view of cabinet base
Pos. 1 Exhaust air
*1 14 mm holes for floor mounting
Obtain anchors locally.
*2 Surface (area with thick outline) for cable feed from the floor (cable duct).
*3 The cables can be laid over the floor to the base from all sides after removing the
base panels, but not from the front.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 97
Page 97 of 130
Image System 7.2
Fig. 49: Image system
Pos. A Front view
Pos. B Side view
Pos. C Top-down view
Pos. 1 Exhaust air
Pos. 2 Air intake
Pos. 3 Castors
Pos. 4 Wall
Pos. 5 Cable loop approx. 2 m on the floor under the image system for service
98 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 98 of 130
*1 Cable outlet; cable lead-in is possible through the floor or wall outlet.
*2 Under normal circumstances, no side spacing to walls or other components is nec-
essary.
The image system can be moved into a position for service using the castors so that
it is accessible from all sides (approx. 0.5 m on each side).
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 99
Page 99 of 130
Floor Stand Ceiling Outlet 7.3
Fig. 50: Floor stand ceiling outlet: A = cable outlet in the installation ceiling / B = cable outlet edge trim
Pos. 1 M10 threaded rods
Pos. 2 Drop ceiling
Pos. 3 Housing
Pos. 4 Cover cap
Pos. 5 Ceiling opening
Pos. 6 Tabs can be installed in the 25 mm radius area
Pos. 7 Outlet dia. approx. 100 mm
100 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 100 of 130
*1 Ceiling mounted, tensile force per screw is less than 1000 N.
*2 Threaded rod spacing
*3 Cable lead-in trim. Cable inlet is cut into the housing.
Cable channel inside dimensions are min. 60 x 160 mm
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 101
Page 101 of 130
Control Room Distributor (BTEE) 7.4
Installation location:
Below the console or on the wall. If needed, the control room distributor can also be set
up directly on the floor (wall anchoring required).
Fig. 51: Control Room Distributor (BTEE)
Pos. 1 Console plate
Pos. 2 Cable lead-in for cables from the system possible from the right and left (see arrow)
Pos. 3 Cable inlet
Pos. 4 Cable lead-in (from above) for monitors, ECC, mouse and keyboard, optional control consoles, remote power archive unit (only if
the image system is in the equipment room)
*1 Mounting spacing, obtain mounting materials on site.
102 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 102 of 130
Control Consoles (Option) 7.5
Fig. 52: Control console (option)
Pos. 1 Control room distributor
Pos. 2 Height adjustable
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 103
Page 103 of 130
Tabletop Opening for Control Modules and ECC 7.6
Fig. 53: Tabletop cutout for the control modules and ECC
Pos. 1 Table cutout
Pos. 2 Work surface
Provide an opening in the work table conforming to the configured control modules and, if
applicable, the ECCs:
Table Control Module (TCM)
Floor Stand Control Module (SCM)
Collimator Control Module (CCM)
EEC
the EEC can also be installed in a different location, separately from the control mod-
ules. Unline with the control modules, the ECC is also suitable for free setup, i.e., it does
not have to be recessed into the tabletop.
104 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 104 of 130
Second Data Display (Option) 7.7
The display can be placed on an on-site console or installed on the wall.
Fig. 54: Second Data Display (Option)
Pos. 1 Mounting points
Pos. 2 Data Display
Pos. 3 Lateral pivot range
*1 The mounting materials (four 8 x 70 wood screws and screw anchors) are included
in the shipment.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 105
Page 105 of 130
Stationary Upper Body Radiation Shield, Surgery Lamp (Option)7.8
With installation of an injector stand, it is not permissible to also add a surgery lamp
or a radiation shield.
The spacing between the bottom edge of the radiation shield ceiling column and the floor
is RH - 820 mm (RH = room height). Recommendation: For room heights measuring less
than 2900 mm, it is better to use the movable upper body radiation shield and not the sta-
tionary version.
106 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 106 of 130
Fig. 55: Stationary upper body radiation shield, surgery lamp (option)
Pos. 1 Installation plate
Pos. 2 Surgery lamp, 1 or 3 beam
Pos. 3 Ceiling column
Pos. 4 Studs for radiation shield or injector stand
Pos. 5 Double articulated arm
Pos. 6 Large pane
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 107
Page 107 of 130
Installation plate approx. 23
kg
1. Ceiling column with extender, spring-loaded arm and large disk
or
2. ceiling column with extender, spring-loaded arm and ceiling
lamp or
3. maximum configuration (1-beam lamp and large disk)
4. maximum configuration (3-beam lamp and large disk)
approx. 36 kg
approx. 30 kg
approx. 50 kg
approx. 51 kg
108 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 108 of 130
Movable Upper Body Radiation Shield, Surgery Lamp (Option) 7.9
Fig. 56: Movable upper body radiation shield, surgery lamp (option)
Pos. 1 Movable cart
Pos. 2 Longitudinal rail
Pos. 3 Surgery lamp, 1 or 3 beam
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 109
Page 109 of 130
Pos. 4 Ceiling column
Pos. 5 Double articulated arm
Pos. 6 Large disk
*1: Alternatively, the short column
A second cart for the injector head is possible (separate Part No.).
Longitudinal rail approx. 30 kg
Movable cart approx. 5 kg
1. Ceiling column with extender, spring-loaded arm and large disk
or
2. ceiling column with extender, spring-loaded arm and ceiling
lamp or
3. maximum configuration (1-beam lamp and large disk)
4. maximum configuration (3-beam lamp and large disk)
approx. 36 kg
approx. 30 kg
approx. 50 kg
approx. 51 kg
110 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 110 of 130
Control Console Cart Ceiling Outlet 0
Fig. 57: Monitor or control cart ceiling outlet
Pos. 1 e.g. Unistrut profile
Pos. 2 Installation parts (included in shipment)
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 111
Page 111 of 130
Pos. 3 Cable outlet
Pos. 4 Bracket (included in shipment)
Pos. 5 Bracket installation on the profile (on-site)
System Ceiling Installation with Monitor Trolley Option 0
Ceiling Installation with Movable Upper Body Radiation Shield (Option)
Recommendation: ceiling grid of 675 mm
112 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 112 of 130
Fig. 58: Ceiling installation with mobile upper body radiation shield (option)
Pos. 1 Grid spacing
Pos. 2 Do not plan any lighting components, ventilation outlets, sprinkler elements, etc. between the longitudinal rails
Pos. 3 Radiation shield
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 113
Page 113 of 130
Ceiling Installation with Stationary Upper Body Radiation Shield (Option)
Recommendation: ceiling grid of 675 mm
*1 Orientation point/isocenter for floor stand in the head-end position
*2 Floor stand ceiling outlet (see Detail Planning > Floor Stand Ceiling Outlet)
*3 Monitor trolley ceiling outlet
*4 observe the maximum admissible rail overhang.
*5 The ceiling rails (option) for the radation shield, surgery lamp, injector stand (see
Detail Planning > Movable Upper Body Radiation Shield, Surgery Lamp (option));
length when shipped: 4 m, can be shortened.
IN1 Injector stand installed on the injector ceiling column in the radiation shield rails
(option).
SU Surgery lamp (option), see Installation Preparations > On-site Power Cables, Detail
Planning > Movable Upper Body Radiation Shield, Surgery Lamp (Option).
TR1 Control console cart (option) (see Detail Planning > Control Console Cart (Option))
114 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 114 of 130
Fig. 59: Ceiling installation with stationary upper body radiation shield (option)
*1 Orientation point/isocenter for floor stand in the head-end position
*2 Floor stand ceiling outlet (see Detail Planning > Floor Stand Ceiling Outlet)
*3 Monitor trolley ceiling outlet
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 115
Page 115 of 130
*4 Installation plate (option, see Detail Planning > Stationary Upper Body Radiation
Shield, Surgery Lamp (Option)) for
Radiation Shield and Surgery Lamp
or Injector Stand
*5 With a smaller ceiling grid, move the installation plate to the side until it is centered
to the ceiling grid.
IN2 Injector stand installed on the injector ceiling column in the radiation shield rails
(option).
SU Surgery lamp (option) (see Installation Preparations > On-site Power Cables,
Detail Planning > Stationary Upper Body Radiation Shield, Surgery Lamp
(Option)).
TR1 Control console cart (option) (see Detail Planning > Control Console Cart (Option))
116 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 116 of 130
Control Console Cart (option) 7.10
The control console cart can be moved on castors.
Cable lead-in is via a ceiling outlet. The cable outlet is the same design as the cable outlet
for the monitor trolley (see Detail Planning > Monitor Trolley Ceiling Outlet).
Fig. 60: Control Console Cart (option)
Pos. 1 Clamp rail for ECC
Pos. 2 clamp rail for control modules
Pos. 3 Cable holder
Pos. 4 Corrugated hose 30 (6 m to ceiling outlet)
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 117
Page 117 of 130
Injector Wall Connection Box (Option) 7.11
Fig. 61: Injector wall outlet (option)
Pos. 1 Cable duct
*1 Mounting points, obtain mounting materials on site.
118 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 118 of 130
Planning Recommendation for the Injector Wall Connection 0
Fig. 62: Planning recommendation for the injector wall connection
IW Injector wall connection box (option, injector wall outlet)
*1 Orientation point/isocenter for floor stand in the head-end position
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 119
Page 119 of 130
Injector Rack Mount Unit (Option) 7.12
Versions
- With table stand:
For space reasons, the control cable between the table stand-injector control cannot
be lead through the table
- or with a fixed ceiling column
- or with a movable ceiling column (used in the rail system for the radiation shield)
Allowed Injectors:
Installation Position see Installation Preparations-> Upper Body Radiation Shield, Sur-
gery Lamp, Injector (Option).
Injector control unit on an on-site wall console, etc.; if possible, place in the equipment
room.
Cable lengths:
Fig. 63:
Pos. 1 ULI (in control room distributor or wall outlet)
Pos. 2 Injector control console
Pos. 3 Injector control unit
Pos. 4 Injector head
Injector Comment
ANGIOMAT ILLUMENA Table stand: In combination with the tilt or OR table,
the injector is released only with the air detector.
MEDRAD MARK V PROVIS with ODU connector
MEDRAD AVANTA Table installation only
120 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 120 of 130
NOTE The current data for the allowed injectors are described in the
SIR PM AX 39...

Injector Stand
Cable lengths (m)
l 1 l 2 l 3
ANGIOMAT
ILLUMENA
5,0 24,0 24,0
MEDRAD MARK V
PROVIS
3,0 max.30.5 max.30.5
MEDRAD AVANTA 3,0 20,0 20,0
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 121
Page 121 of 130
Connection of non-Siemens ECGs 7.13
If no Sensis is configured, triggering of exposure can be synchronized to a non-Sie-
mens ECG signal (QRS pulse). In addition, the display of the analog ECG signal is pos-
sible. Here, the non-Siemens measuring station must meet the following specifications:
- galvanic separation of the electrical signals
- Cabling meets the requirements defined by EN 60601-1-2 (electro-magnetic interfer-
ence...)
ECG trigger signal:
Input impedance
[]
Signal level
[V]
High pulse
width
[msec]
LOW (min...max) HIGH (min...max) (min...max)
1 - 1.0 ... + 0,8 + 2,0 ... + 7,0 1 ...50
Connection of the ECG signal cable is made to the RTC in the system control cabinet.
Analog ECG signal:
Input impedance
[]
Amplitude
[V]
Offset
[V]
(min...max) (min...max)
100
+ 0,6... + 1,3
(typical, 1 Vpp)
- 5...+ 5
Adaptation of the ECG signal is made in the system control cabinet on the ECG board in
the RTC (A).
122 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 122 of 130
DCS Location per Version 2 7.14
System without the MULTISPACE.F Option 0
Fig. 64: System without the MULTISPACE.F option
Pos. 1 P1 cable fixpoint on the ceiling for the floor stand
Pos. 2 D1 cable fixpoint on the ceiling for the DCS
*1 Dimensions without brackets:
Dimensions in brackets:
Table longitudinal movement not restricted
Table longitudinal movement limited by the room width
*2 Dimensions without brackets: for Peri, Tilt and OR tables (including 500 mm safety distance
to the wall)
Dimensions in brackets: for the basic table
*3 Orientation point/Isocenter Floor stand in the head-end position.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 123
Page 123 of 130
System Ceiling Installation 0
Ceiling Installation with Movable Upper Body Radiation Shield (Option)
Recommendation: ceiling grid of 675 mm
*4 Isocenter in the Left Position
*5 Orientation point/Floor fixpoint Patient table
124 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 124 of 130
Fig. 65: Ceiling installation with movable upper body radiation shield (option)
Pos. 1 Grid spacing
Pos. 2 Do not plan any lighting components, ventilation outlets, sprinkler elements, etc. between the longitudinal rails.
Pos. 3 DCS
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 125
Page 125 of 130
Pos. 4 Radiation shield
*1 Orientation point/isocenter for floor stand in the head-end position
*2 Floor stand ceiling outlet (see Detail Planning > Floor Stand Ceiling Outlet)
*3 DCS ceiling outlet
*4 observe the maximum admissible rail overhang.
*5 The ceiling rails (option) for the radation shield, surgery lamp, injector stand (see
Detail Planning > Movable Upper Body Radiation Shield, Surgery Lamp (option));
length when shipped: 4 m, can be shortened.
IN1 Injector stand installed on the injector ceiling column in the radiation shield rails
(option).
SU Surgery lamp (option) (see Installation Preparations > On-site Power Cable, Detail
Planning > Movable Upper Body Radiation Shield, Surgery Lamp (Option)).
TR1 Control console cart (option) (see Detail Planning > Control Console Cart (Option))
126 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 126 of 130
Ceiling Installation with Stationary Upper Body Radiation Shield (Option)
Fig. 66: Ceiling installation with movable upper body radiation shield (option)
Pos. 1 Do not plan any lighting components, ventilation outlets, sprinkler elements, etc. between the longitudinal rails.
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 127
Page 127 of 130
Pos. 2 DCS
Pos. 3 Radiation shield
*1 Orientation point/isocenter for floor stand in the head-end position
*2 Floor stand ceiling outlet (see Detail Planning > Floor Stand Ceiling Outlet)
*3 DCS ceiling outlet
*4 observe the maximum admissible rail overhang.
*5 Installation plate (option, see Detail Planning > Stationary Upper Body Radiation
Shield, Surgery Lamp (Option)) for
Radiation Shield and Surgery Lamp
or Injector Stand
*6 With a smaller ceiling grid, move the installation plate to the side until it is centered
to the ceiling grid.
IN2 Injector stand installed on the injector ceiling column in the radiation shield rails
(option).
SU Surgery lamp (option) (see Installation Preparations > On-site Power Cables, Detail
Planning > Stationary Upper Body Radiation Shield, Surgery Lamp (Option)).
TR1 Control console cart (option) (see Detail Planning > Control Console Cart (Option))
128 Detail Planning
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 128 of 130
Ceiling Installation with a second DCS (Option) 7.15
Siemens AXA4-100.891.01.06.02 AXIOM Artis FC/FA
01.08 CS CD AX
Detail Planning 129
Page 129 of 130
Fig. 67: Ceiling installation with second DCS (option)
Pos. 1 Grid spacing
Pos. 2 DCS
Pos. 3 Radiation shield
*1 Orientation point/isocenter for floor stand in the head-end position
*2 Floor Stand Ceiling Outlet (see)
*3 DCS ceiling outlet
*4 observe the maximum admissible rail overhang.
*5 The ceiling rails (option) for the radation shield, surgery lamp, injector stand (see);
length when shipped: 4 m, can be shortened.
IN2 Injector stand installed on the injector ceiling column in the radiation shield rails
(option).
SU Surgery lamp (option)
TR1 Control Console Cart (option)
130 Changes to Previous Version
AXIOM Artis FC/FA AXA4-100.891.01.06.02 Siemens
01.08 CS CD AX
Page 130 of 130
8- 8Changes to Previous Version
Chapter Section Changes
Complete document revised editorially.
Cover page
General Information
Room Planning
Installation Preparations
System Connections
Technical Data
Transport and Storage
Detail Planning
Changes to Previous Version

You might also like