Description

Patented Aquacon

Filter Cartridges
have a unique high-capacity inner
absorbent medium which removes
all free and emulsified water from
hydrocarbon fuels down to less than 5
ppm in the effluent. Absorbed water is
chemically locked into this medium.
When a cartridge reaches its water
holding capacity, its accordion pleats
swell and cause an increase in the
differential pressure which signals the
operator to change the cartridge.
Solid contaminants are removed
by the cartridges particulate filter
media layers. The pleated accordion
style design provides a large surface
area for maximum dirt holding
capacity. Models are offered for particle
filtration down to 1/2 micrometer size
with 98% plus efficiency. Performance
is not affected by the presence
of common surface active agents.
Compact Aquacon Cartridges are
quick and easy to install. Models are
available to fit most existing standard
housings. Refer to Cartridge Selection
Table on reverse side.
Use Form 1846 for cartridge changeout
recommendations at flowrates less
than rated flow.
Aquacon

ACO
EI 1583 6th Edition Aviation Fuel Monitor
Remove Water and Dirt from Jet Fuel and
Avgas Outside-to-In Flow Cartridges
Contact Information:
Parker Hannifin Corporation
Velcon Filtration Division
1210 Garden of the Gods Road
Colorado Springs, CO 80907
phone 719 531 5855
fax 719 531 5690
vfsales@parker.com
www.velcon.com
Features
Free and emulsified water
removal to less than 5 ppm
1/2 micrometer particle
removal
Provides protection against
slugs of water
Pressure increase signals
need for cartridge change
Use with existing filter
housings
Description
Patented Aquacon

Filter Cartridges
have a unique high-capacity inner
absorbent medium which removes
all free andemulsified water from
hydrocarbon fuels down to less than 5
ppm in the effluent. Absorbed water is
chemically locked into this medium.
When a cartridge reaches its water
holding capacity its accordionpleats
style design provides a large surface
area for maximum dirt holding
capacity. Models are offered for particle
filtration down to 1/2 micrometer size
with 98%plus efficiency. Performance
is not affected by the presence
of common surface active agents.
Compact Aquacon Cartridges are
quick andeasy to install Models are
Parker Hannifn Corporation
Velcon Filtration Division
1210 Garden of the Gods Road
Colorado Springs, CO 80907 USA
tel +1 719 531 5855
www.velcon.com
2013 Parker Hannifn Corporation. Product names are trademarks or registered trademarks of their respective companies. VEL1681R19 10/13
ACO Cartridge Selection Table
Model
Number
Micron
Ratings
Inside
DIA (in)
Outside
DIA (in) Length (in)
Collapse
Pressure
(psi)
Max. Flow
Rate
(USGPM)
Interchange
Information
ACO-21001P 0.5 1
1
32 2
5
8 9
3
4 60 15 Fits VF-31E Housing
ACO-31001P 0.5 1
5
16 3 9
3
4 75 20 Fits Purolator Vessel PR-172-3
ACO-40501SPP 0.5 1-12NF 3
3
4 5
1
2 60 10 Use with head SPH-2
ACO-40801P 0.5 1
3
4 4 8 100 13 Rellumit Replacement
ACO-40901SPP 0.5 1
3
8 -12NF 3
3
4 8
1
2 60 15 Use with head SPH-3
ACO-41201P 0.5 1
3
4 4 12
1
4 100 20
Replaces Facet C-707;
Purolator Vessel PAG-50
ACO-41601P 0.5 1
3
4 4 15
13
16 100 27 Rellumit Replacement
ACO-41801P 0.5 1
3
4 4 18 100 30
Replaces Facet C-706 and
Keene BP-419, BP-518
ACO-41901P 0.5 1
3
4 4 19
7
8 175 32 Rellumit Replacement
ACO-51201P 0.5 1
7
8 5
5
8 12
1
4 75 50 Fits VF-61 Housing
ACO-512P3P 0.3 1
7
8 5
5
8 12
1
4 75 50 Fits VF-61 Housing
ACO-60801P 0.5 3
1
2 6 8
1
4 100 30 Omeco 6 x 8 Replacement
ACO-60901P 0.5 1
1
2 6 9
11
16 100 36
Fits Fram/Facet VFCS-21
(Element CC-21-7); VF-609
ACO-609P3P 0.3 1
1
2 6 9
9
16 100 36
Fits Fram/Facet VFCS-21
(Element CC-21-7); VF-609
ACO-61201P 0.5 1
1
2 6 13
3
4 100 48
Fits Fram/Facet VFCS-22
(Element CC-22-7)
ACO-61401P 0.5 3
1
2 6 14
1
2 175 58 Qualified to EI 1583 6th Edition
ACO-62201PTB 0.5 3
1
2 6 22 175 88 Qualified to EI 1583 6th Edition
ACO-62901P 0.5 3
1
2 6 28
3
4 175 115 Qualified to EI 1583 6th Edition
ACO-63301P 0.5 3
1
2 6 33
1
4 175 133 Qualified to EI 1583 6th Edition
ACO-64401P 0.5 3
1
2 6 43
1
4 175 173 Qualified to EI 1583 6th Edition
ACO-64401PTB 0.5 3
1
2 6 44 175 176 Qualified to EI 1583 6th Edition
ACO-71801P 0.5 2
1
2 6
1
4 18 75 65 Fits VF-71E Housing
NOTE: 1/2 micron rated
Aquacon

Cartridges are
recommended for use with jet fuel
and avgas. Effluent fuel quality
meets requirements for EI 1583 6th
Edition.
CAUTION: DO NOT USE WITH
PRE-MIXED FUELS CONTAINING
ANTI-ICING ADDITIVES (FSII)
Due to Velcons continuing product improvement, drawings, specifications and pictures are subject to change without notice.
Technical Information
1. Max. operating temp.: 160F
(71.1C)
2. Micron ratings are nominal at
98%+ efficiency
3. Aquacon Cartridges can significantly
reduce flow when loaded with water
or dirt. Appropriate precautions
should be taken in applications where
fuel flow must be maintained or
where surge conditions can occur.
4. Replace the cartridge if the
differential pressure exceeds 25
psid. For service life information,
please refer to Operating
Procedure #1839 or consult
your company fuel handling
procedures.
5. Typical water holding capacity for
ACO-61401P is 700-800 ml.

You might also like