You are on page 1of 2

T

h
e

i
n
f
o
r
m
a
t
i
o
n

p
r
o
v
i
d
e
d

i
n

t
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

c
o
n
t
a
i
n
s

g
e
n
e
r
a
l

d
e
s
c
r
i
p
t
i
o
n
s

a
n
d
/
o
r

t
e
c
h
n
i
c
a
l

c
h
a
r
a
c
t
e
r
i
s
t
i
c
s

o
f

t
h
e

p
e
r
f
o
r
m
a
n
c
e

o
f

t
h
e

p
r
o
d
u
c
t
s

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
T
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

i
s

n
o
t

i
n
t
e
n
d
e
d

a
s

a

s
u
b
s
t
i
t
u
t
e

f
o
r

a
n
d

i
s

n
o
t

t
o

b
e

u
s
e
d

f
o
r

d
e
t
e
r
m
i
n
i
n
g

s
u
i
t
a
b
i
l
i
t
y

o
r

r
e
l
i
a
b
i
l
i
t
y

o
f

t
h
e
s
e

p
r
o
d
u
c
t
s

f
o
r

s
p
e
c
i
f
i
c

u
s
e
r

a
p
p
l
i
c
a
t
i
o
n
s
.
I
t

i
s

t
h
e

d
u
t
y

o
f

a
n
y

s
u
c
h

u
s
e
r

o
r

i
n
t
e
g
r
a
t
o
r

t
o

p
e
r
f
o
r
m

t
h
e

a
p
p
r
o
p
r
i
a
t
e

a
n
d

c
o
m
p
l
e
t
e

r
i
s
k

a
n
a
l
y
s
i
s
,

e
v
a
l
u
a
t
i
o
n

a
n
d

t
e
s
t
i
n
g

o
f

t
h
e

p
r
o
d
u
c
t
s

w
i
t
h

r
e
s
p
e
c
t

t
o

t
h
e

r
e
l
e
v
a
n
t

s
p
e
c
i
f
i
c

a
p
p
l
i
c
a
t
i
o
n

o
r

u
s
e

t
h
e
r
e
o
f
.
N
e
i
t
h
e
r

S
c
h
n
e
i
d
e
r

E
l
e
c
t
r
i
c

I
n
d
u
s
t
r
i
e
s

S
A
S

n
o
r

a
n
y

o
f

i
t
s

a
f
f
i
l
i
a
t
e
s

o
r

s
u
b
s
i
d
i
a
r
i
e
s

s
h
a
l
l

b
e

r
e
s
p
o
n
s
i
b
l
e

o
r

l
i
a
b
l
e

f
o
r

m
i
s
u
s
e

o
f

t
h
e

i
n
f
o
r
m
a
t
i
o
n

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
Jun 27, 2014
1
Product data sheet
Characteristics
CAD32GD
TeSys D control relay - 3 NO + 2 NC - <= 690
V - 125 V DC standard coil
Main
Range TeSys
Product name TeSys CAD
Product or component
type
Control relay
Device short name CAD
Contactor application Control circuit
Utilisation category AC-14
AC-15
DC-13
Pole contact composi-
tion
3 NO + 2 NC
[Ue] rated operational
voltage
<= 690 V AC 25...400 Hz
Control circuit type DC standard
Control circuit voltage 125 V DC
Complementary
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
[Ith] conventional free air thermal current 10 A at <= 60 C
Irms rated making capacity 250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
[Icw] rated short-time withstand current 140 A 100 ms
120 A 500 ms
100 A 1 s
Associated fuse rating 10 A gG conforming to IEC 60947-5-1
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V certifications CSA
600 V certifications UL
Mounting support Plate
Rail
Connections - terminals Screw clamp terminals 2 cable(s) 1...4 mm - cable stiffness: solid - without cable
end
Screw clamp terminals 1 cable(s) 1...4 mm - cable stiffness: solid - without cable
end
Screw clamp terminals 2 cable(s) 1...2.5 mm - cable stiffness: flexible - with ca-
ble end
Screw clamp terminals 1 cable(s) 1...4 mm - cable stiffness: flexible - with cable
end
Screw clamp terminals 2 cable(s) 1...4 mm - cable stiffness: flexible - without ca-
ble end
Screw clamp terminals 1 cable(s) 1...4 mm - cable stiffness: flexible - without ca-
ble end
Tightening torque 1.2 N.m - on screw clamp terminals - with screwdriver flat 6 mm
1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit voltage limits 0.1...0.25 Uc drop-out
0.7...1.25 Uc operational
Operating time 15...25 ms coil de-energisation and NC closing
47...63 ms coil energisation and NC opening
16...24 ms coil de-energisation and NO opening
53...72 ms coil energisation and NO closing
Mechanical durability 30 Mcycles
Operating rate 180 cyc/mn
Time constant 28 ms
2
Inrush power in W 5.4 W at 20 C
Hold-in power consumption in W 5.4 W at 20 C
Minimum switching voltage 17 V
Minimum switching current 5 mA
Non-overlap time 1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
Insulation resistance > 10 MOhm
Height 77 mm
Width 45 mm
Depth 93 mm
Product weight 0.58 kg
Environment
Standards BS 4794
EN 60947-5
IEC 60947-5-1
NF C 63-140
VDE 0660
Product certifications CSA
UL
IP degree of protection IP2x front face conforming to VDE 0106
Protective treatment TH conforming to IEC 60068
Ambient air temperature for operation -40...70 C
Ambient air temperature for storage -60...80 C
Operating altitude 3000 m without derating in temperature
Mechanical robustness Vibrations control relay closed 4 Gn, 5...300 Hz IEC 60068-2-6
Vibrations control relay open 2 Gn, 5...300 Hz IEC 60068-2-6
Shocks control relay closed 15 Gn for 11 ms IEC 60068-2-27
Shocks control relay open 10 Gn for 11 ms IEC 60068-2-27
Offer Sustainability
Sustainable offer status Green Premium product
RoHS
Compliant - since 0627 - Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Product environmental profile Available Download Product Environmental
Product end of life instructions Need no specific recycling operations

You might also like