Power
uninterruptible power supply either active parallel or hot-standby
around the world for its reliability and
performance, words simply can’t explain mode, ready to take over the load
automatically in the event of a critical
its phenomenal success.
component failure.
downtime is reducing, both in terms of If one UPS fails - other UPS’s can
still accommodate the load.
user expectations and technical
requirements. 24x7 availability is no In hot-standby mode, one or more units
longer a competitive advantage; it has support the load, while the remaining
now become a commercial requirement. members of the array functions as
standby unit.
Built in system redundancy is now
normal practice. From RAID devices The standby unit is continually on-line,
through to complete servers running as but only takes over the load when one
mirror images, businesses are investing of the primary units is no longer active.
in technology, which can deliver This means that there is no break
maximum availability and eliminate those when power is transferred, and the
last few percentage points of downtime. load continues to be supported
When business information is dependent without disturbance.
on the availability of mains power, no- UPS UPS UPS
● CUSTOMISABLE ALARM
BOARD FOR INTEGRATION INTO
AN EXISTING BUILDING
MANAGEMENT SYSTEM (BMS).
● NO INTERNAL PASSWORD
LOCKOUT, SERVICING CAN BE DONE
BY ANY QUALIFIED TECHNICIAN.
NOTE: NOT ALL MANUFACTURERS OFFER
THIS FACILITY.
● EASY-TO-INSTALL BATTERY
STRINGS.
● RS 232 INTERFACE AS
STANDARD PROVIDES
COMMUNICATION ON A MULTI- ● OPTIONAL LOCAL AND
POINT NETWORK. REMOTE EMERGENCY POWER
OFF (EPO).
MANUAL AND STATIC BY-PASS CONTROL TO PROTECT
TO PROTECT All T2000 UPS come network-ready, with optional SNMP &
A manual by-pass switch allows power to be transferred directly HTTP adaptor. Use your preferred SNMP management
to the mains without disturbance to the load. The UPS can then application or the provided HTTP GUI through your web browser
be safely powered down for maintenance or repair, on to monitor and control the UPS from anywhere on the network.
completion of the work the UPS can be powered up and the As an alternative, specialised UPS management software is
load once again transferred back to the UPS with no interruption available for critical applications.
in service. If the power demand of your equipment exceeds the
The T2000 can be configured to send alerts over the network or
overload level of the UPS the static switch defaults to the mains
out-of-band via modem to your pager, mobile phone or remote
ensuring continuous power in the event of system abuse or short
workstation. The T2000 is equipped with RS232 interface for
term overload conditions.
serial communication and can also be supplied with volt-free
contacts for SCADA applications.
TIME TO PROTECT
For your visits to the UPS itself, the T2000 is equipped with a
In addition to providing sufficient run-time to save files and simple, clear LCD screen displaying all necessary system
shutdown operating systems, autonomies of up to 8 hours are information.
available allowing you the option to complete a day’s work
without disturbance to your equipment, even during a power cut!
• User-customisable commands and messages SNMP has its own IP address and
connects directly onto the network.
• Multiple UPS control from a single computer