You are on page 1of 4

All-inside meniscal repairs have

never been stronger or easier.


Now with an easier-sliding knot and ULTRABRAID™ suture.
1 Deploy preloaded
implant 1. 2 Deploy preloaded
implant 2.

THE TECH
NIQUE

The ULTRA FAST-FIX™ Meniscal When the original FAST-FIX™ Meniscal Repair System was
introduced in 2001, it set the benchmark for minimally-
Repair System is a unique all- invasive, all-inside repairs. Thanks to its preloaded
inside implant system, offering implants, pre-tied sliding knot, and innovative pusher/
cutter device, this innovative system lets you deploy
the fixation strength of an two implants vertically or horizontally on either side of
open-vertical mattress stitch the meniscus, tighten the suture and trim the excess.
without the invasive surgical Building on its proven clinical success, the all-new
procedure normally required ULTRA FAST-FIX system adds easier knot sliding and
for suture-based repairs. stronger suture. The result is a faster, more secure
meniscal repair system that will help maximize the
chances of a successful meniscus tear recovery.
3 Slide the pre-tied 4 Use the reverse-curved 5 Completed repair with
vertical and horizontal
knot, tighten the needle to repair tears
on the inferior surface mattress stitches.
suture, and trim the
excess. (tibial side).

The only product of its kind.


Fast and easy Easy knot sliding with PLLA absorbable
.
Unlike conventional suture-based repair
systems, the ULTRA FAST-FIX system is
ULTRABRAID™ suture implants
an implant system with a pre-tied, self- Offers advantages over traditional Bioabsorbable version of ULTRA FAST-FIX.
sliding knot that eliminates the need for polyester suture, including higher knot-
intra-articular knot tying. breaking strength, increased lubricity and
a stronger resistance to fraying. Curved and reverse-
Strong and PEEK-OPTIMA® curved needles
clinically proven high strength Curved needles promote safer and easier
access to a multitude of tear sites. The
Provides a strong, reproducible
and reliable meniscal repair with non-absorbable, reverse-curved needle is designed for
repairing tears on the inferior surface.
biomechanical properties equal to that
of the open, vertical mattress stitch
polymer implants Because the needle’s point is on the
opposite side of the curve, it can safely
suture technique. PEEK-OPTIMA polymer lends
enter the inferior area without skiving the
confidence that the implant will
Contains no hard resist breakage when used with
meniscus or the tibial plateau.
high-strength ULTRABRAID suture.
device heads
Minimizes trauma to articular cartilage

A Stronger and Stiffer Repair than Competitive Devices

After 1000 cycles between An evaluation of the mechanical properties of the ULTRA FAST-FIX 1. Zantop T, Eggers A, Musahl V, Weimann A, Petersen W.
5N and 20N. All values are Meniscal Repair System showed a significant increase in ultimate Cyclic testing of flexible all-inside meniscus suture anchors.
means +/- standard errors. strength and stiffness, and a decrease in elongation compared to AM J Sports Med. 2005; 33:1-7.
Bovine meniscus model. ETHIBOND®, RAPIDLOC® and the conventional, clinically successful 2. Data on file at Smith & Nephew.
FAST-FIX device2. This in vitro mechanical evaluation of meniscal
repair devices employed cyclic and load-to-failure mechanical tests
on a repaired bovine meniscus.
90° Diamond Rasp

45° Diamond Rasp

Knot Pusher/Suture Cutter

Split Cannula

Suture Funnel Penetration Limiter


Trimmable Depth

pth Probe
Meniscal De

nula
d Can
Slotte

Knot pusher/
cutter
This innovative
device combines
Split cannula two instruments in
Safely introduces one, allowing you
the delivery needle to advance the
into the joint, keeps knot to achieve the
Slotted debris off the needle desired tension
cannula and protects the and trim the excess
Introduces the articular cartilage. suture. The cutter is
delivery needle into designed especially
45° and 90° the joint safely; aids to cut ULTRABRAID™.
diamond in steering to the
rasps desired position; can
be used to reduce the
Trimmable These angled,
tear; and minimizes
diamond rasps are
depth designed specifically needle skiving.
penetration to freshen the edge For inferior surface
repairs, the cannula
Meniscal limiter of the meniscal tear
can be used to lift the
surfaces prior to
depth probe Controls the depth meniscus, providing
Measures the depth of needle penetration, repair, to induce a greater accessibility
enhancing safety bleeding response.
of penetration to the tear.
required for the in patients and
ULTRA FAST-FIX™ allowing predictable
needle. meniscocapsular
placement,
while avoiding
neurovascular
structure injury.1

Ordering Information
72201491 ULTRA FAST-FIX, Curved 014549 45 degree Diamond Rasp, reusable
72201492 ULTRA FAST-FIX, Reverse Curved 014550 90 degree Diamond Rasp, reusable
72201494 ULTRA FAST-FIX AB, Curved 7210450 Suture Funnel, sterile, box of 10
72201495 ULTRA FAST-FIX AB, Reverse Curved 7209950 Suture Threaders, sterile, box of 10
72201537 Knot Pusher/Suture Cutter 011703 Sterilization Tray
7210977 Slotted Cannula, reusable Contact your sales representative about information regarding the
ULTRA Fast-Fix Technique Guide
015186 Meniscal Depth Probe, reusable
1. Coen, Caborn, Urban et. al., Arthroscopy 1998

™ Trademarks of Smith & Nephew.


Endoscopy www.smith-nephew.com
Certain marks Registered US Patent and Trademark Office.
Smith & Nephew, Inc. T +1 978 749 1000 All other trademarks acknowledged.
Andover, MA 01810 US Customer Service: +1 800 343 5717 ©2007 Smith & Nephew. All rights reserved.
USA International Customer Service: +1 978 749 1140 Printed in USA. 12/07 10600353 Rev. A