You are on page 1of 8

A50010-A3-H101-3-76D1 413

Hardware Layouts
FastLink V7
GSD:TAB
27.14 LUOT-A line Terminating Unit
27.14.1 Local Monitoring and Alarm Signaling
One green and one red LED are located on the LT2ME1 and are visible even when the
front panel is closed. They show the operating and alarm status (A, B and S alarm) of
the line terminating unit according to the alarm table, see Tab. 27.37.
In addition, 5 SMD LEDs (1 x green, 3 x red and 1 x yellow) are located on the front of
the unit to display fault and operating statuses. These 5 SMD LEDs are only visible if the
shelf panel is removed. The green SMD LED lights up if at least one module is detected
and flashes if no module is detected. The yellow SMD LED lights up if there is a QD2
connection.
LED red LED green Betriebszustand
off off No operating voltage
on off Urgent alarm (A alarm)
flashes on B alarm
an on Fault/service (S alarm)
any flashes Forced laser startup
off on Normal operation
Tab. 27.37 Operating Status Display
414 A50010-A3-H101-3-76D1
GSD:TAB Hardware Layouts
FastLink V7
Alarm criterion A alarm B alarm S alarm ZA(A) ZA(B) F1out F2out
F1in
LOS (CER>10
-3
)
x x x Laser off AIS
CER >10
-5
/10
-6 2)
x x x
F2in
LOS x x x AIS
AIS x
Internal
Faulty internal test x x x Laser off AIS
T3LOS
1)
x x x
LPTOL x x x Laser off AIS
LBTOL x x x
near loop LT/F1 (Ug2) x Laser off
near loop LT/F2 x AIS
remote loop NT/F2 x AIS
Laser off x Laser off
x Action is carried out
1) This alarm can be suppressed
2) Configurable
Tab. 27.38 LUOT-A Alarm Table
A50010-A3-H101-3-76D1 415
Hardware Layouts
FastLink V7
GSD:TAB
27.14.2 Operating Elements of the LUOT-A
The positions of the connectors and the LEDS are shown in Fig. 27.40.
Fig. 27.40 Operating elements of the LUOT-A unit
On the LUOT-A only module plug-in place 1 (X5) is used.
Fig. 27.41 Position of the Jumpers on the Pins of Connector X7
Because the 2nd module slot is not used, no jumpers need to be plugged in at X8
yellow
1)
red
1)
red
1)
red
1)
green
1)
X1 Connector (exchange)
X2 Connector (system)
X5, X3Connector for module Ug2 (module plug-in place 1)
X6, X4free Connector (reserved)
D12 Initial program loader
1) Only visible if front panel is removed
rot
grn
S1
ON
1
10
5
S2
1 4
ON
X5
D12
b20
6
2
4
b1
5
1
3
a20
a1
X3
X2
X1
X6
b20
6
2
4
b1
5
1
3
a20
a1
X4
1
5
3
X8
2
6
4
6
2
4
X7
5
1
3
120 75
5
1
3
5
1
3
6
2
4
6
2
4
As-delivered condition:
120
F2in/out:
416 A50010-A3-H101-3-76D1
GSD:TAB Hardware Layouts
FastLink V7
Switch Slider
unit
Position Function
S1
1
2
3
4
5

ON
ON
ON
ON
ON
Set the SISA address
SISA address bit 2
0
(value for ON = 0, for OFF = 1)
SISA address bit 2
1
(value for ON = 0, for OFF = 1)
SISA address bit 2
2
(value for ON = 0, for OFF = 1)
SISA address bit 2
3
(value for ON = 0, for OFF = 1)
SISA address bit 2
4
(value for ON = 0, for OFF = 1)
S1
7 to 10

always to
OFF
Mode:
reserved
As-delivered variant = OFF
Tab. 27.39 Settings at Switch S1
Slider unit Position Function
1
OFF
1)
ON
T3 input:
High resistance
120
2
OFF
1)
ON
Interface termination QD2 slave port receiving direction (QD2in):
High resistance
120
3
OFF
1)
ON
Interface termination QD2 slave port transmission direction (QD2out):
High resistance
120
4
OFF
1)
ON
No function
1) As-delivered condition
Tab. 27.40 Settings at Switch S2
i
The module responds:
under UniGate: as an LUOT
under ACI < V6.1: not operable
from ACI V6.1: as LUOT-A
A50010-A3-H101-3-76D1 417
Hardware Layouts
FastLink V7
GSD:TAB
Fig. 27.42 Operating elements on the Ug2 module
The yellow LED lights up if the laser is switched on.
X5
b1
b20
a1
a20
yellow
Receiver:
Transmitter:
Laser start key:
418 A50010-A3-H101-3-76D1
GSD:TAB Hardware Layouts
FastLink V7
27.14.3 Assignment of Connectors
Pin A row B row C row
1 (F1an_A2)
2 Qab_A Qab_B
3 (F1an_B2)
4 Qan_A Qan_B
5 (F1ab_A2)
6 ZA(B) ZA(A)
7 (F1ab_B2)
8
9
10
11
12 (OHab_A) (OHan_A)
13
14 (OHab_B) (OHan_B)
15
16 (F1an_A1) (F1an_A1)
17
18 (F1an_B1)
19
20 (F1ab_A1) (F1an_B1)
21
22 (F1ab_B1)
23
24 (F2an_A2) (F1ab_A1) (F2ab_A2)
25
26 (F2an_B2) (F1ab_B1) (F2ab_B2)
27
28 F2ab_A1 F2ab_B1 F2ab_B1
29 F2ab_A1
30 F2an_A1 T3an_A
31 F2ab_B1
32 F2an_B1 T3an_B
Specifications shown in brackets are not used for operation of
the LUOT-A but is reserved for other applications.
Tab. 27.41 Connector X1 of the LUOT-A
A50010-A3-H101-3-76D1 419
Hardware Layouts
FastLink V7
GSD:TAB
Pin A row B row C row
1 GND ZA(B) ZA(A)
2 GND
3
4 MUP
5 GND_S GND_S
6
7 (O64anC)
8
9 (O64abC)
10
11
12 A1 A2
13 GND_S
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28 A4 A0 A3
29
30
31 GND
32 GND
Specifications shown in brackets are not used for operation of
the LUOT-A but is reserved for other applications.
Tab. 27.42 Connector X1 of the LUOT-A
420 A50010-A3-H101-3-76D1
GSD:TAB Hardware Layouts
FastLink V7
27.14.4 Abbreviated Signal Designations
A0 to A4 Backplane address lines
F2out_A1/B1 2-Mbit/s data signal out (output) (F2 line interface 1)
F2in_A1/B1 2-Mbit/s data signal in (input) (F2 line interface 1)
GND Internal chassis ground (0 V central battery)
GND_S Chassis ground of the unit
MUP Negative primary voltage -60 V (-60 V central battery)
Qout_A/B QD2 lines out (output)
Qin_A/B QD2 lines in (input)
T3in_A/B Incoming synchronization clock (T3 reference clock input)
ZA(A) Output for central service supervision (urgent alarm)
ZA(B) Output for central service supervision (non-urgent alarm)