Surge
Protection
Electrical Installations
Photovoltaic
Telecom
Data
Radiocommunication
General Catalog
9th edition
p. 6
DIN
RAIL
p. 60
p. 70
p. 78
p. 94
p. 120
cument could
2013 - This do
D ATA L I N E S U R G E P R O T E C T O R S
p. 108
p. 126
P H O T O V O LTA I C S U R G E P R O T E C T O R S
MISCELLANEOUS
thout notice.
be modified wi
CITEL
Factories
Test Laboratories
Distributors
An international network
France
Subsidiaries
Svres : - Headquarters
- General management
- Administrative and Financial Department
- Sales division : France and Export
- Research and Development
A long history......
1937
1944
1976
1985
1988
1992
1996
2000
2005
2007
2010
2012
CITEL founded.
Manufacture of tubular light bulbs.
Manufacture of the rst Surge Arrester.
CITEL acquired by the present Management.
Light bulb manufacturing discontinued.
CITEL America founded in Miami.
CITEL Electronics GmbH founded in Dsseldorf.
Acquisition of CLAUDE gas tube line from GTE Sylvania at Reims,
and OBSTA.
Establishment of Shangha CITEL Electronics Co., Ltd.
New technology for AC surge protectors (VG series).
New JV for coaxial surge protectors production CITEL Tong Da.
AC surge protectors become the best-selling range
CITEL Russia founded in Moscow
CITEL India founded in New Delhi
Testing labs......
In order to test its products internally for standards compliance and to evolve toward
greater reliability CITEL has several test sites (France, USA, China) equipped with:
The G100K test generator in Reims (France) can produce exceptionally high impulse
current of 100 kA and is used for testing structural lightning protection systems as
well as Type 1 surge protectors.
The specialist in
overvoltage protection
CITELs only business is to protect networks and equipment from
transient overvoltages, in particular those induced by lightning.
For this, CITEL manufactures two complementary products
lines:
- Gas discharge tubes (or GDTs) are the basic passive components used to protect telephone exchanges and equipment from
voltage surges; they are generally installed on telephone networks by telecommunication operators.
- Surge Protection Devices (or SPDs) are units combining several protection components. They may be used by the installer or
by the end customer. They are designed to be incorporated in an
installation to protect all electric, electronic, and data-processing equipment from transient overvoltages.
Transient overvoltages
The users of electronic equipment and telephone and data-processing systems must face the problem of keeping this equipment in operation in spite of
the transient overvoltages induced by lightning.
There are several reasons:
Integration of electronic components makes the equipment more vulnerable.
Interruptions of service are unacceptable.
Data transmission networks cover large areas and are exposed to more
disturbances.
Lightning
Lightning, investigated since Benjamin Franklins rst research in 1749,
has paradoxically become a growing threat to our highly electronic society.
Lightning formation
A lightning ash is generated between two zones of opposite charge,
typically between two storm clouds or between one cloud and the ground.
The ash may travel several miles, advancing toward the ground in successive leaps: the leader creates a highly ionized channel. When it reaches the ground, the real ash or return stroke takes place.
A current in the tens of thousands of Amperes will then travel from
ground to cloud or vice versa via the ionized channel.
Direct effects
At the moment of the discharge, there is an impulse current ow that
ranges from 1,000 to 200,000 Ampere peak, with a rise time of about few
microseconds. This direct effect may be considered as a small factor in
damaging electric and electronic systems, because it is highly localized.
The best protection is still the classic lightning rod or Lightning Protection System (LPS), designed to capture the discharge current and conduct it to a particular point.
Indirect effects
There are three types of indirect electrical effects :
Impact on overhead lines
Such lines are very exposed and may be struck directly by lightning, which
will rst partially or completely destroy the cables, then cause high surge
voltages that travel naturally along the conductors to line-connected
equipment. The extent of the damage depends on the distance between
the strike and the equipment.
Rise in ground potential
The ow of lightning in the ground causes earth potential increases that
vary according to the current intensity and the local earth impedance.
In an installation that may be connected to several grounds (e.g. a link
between buildings), a strike will cause a very large potential difference
and equipment connected to the affected networks will be destroyed or
severely disrupted.
Electromagnetic radiation
The ash may be regarded as an antenna several miles high carrying an
impulse current of several tenth of kilo-amperes, radiating intense electromagnetic elds (several kV/m at more than 1 km).
These elds induce strong voltages and currents in lines near or on
equipment. The values depend on the distance from the ash and the
properties of the link.
Coupling by
radiation
Direct impact
Rise in ground
potential
Impact on
overhead lines
NEMP phenomena
(Nuclear ElectroMagnetic Pulses)
A high-altitude nuclear explosion, above the atmosphere, creates an intense electromagnetic eld (up to 50 kV/m in 10ns), radiated to a ground
area up to 1200 kilometers in radius.
In the ground, the eld induces very large transient overvoltages in power
and transmission lines, antennas, etc., destroying the terminal equipment (power circuit, computer terminals, telephone equipment, etc.).
The eld rise may reach several kV/ns. While it is difcult to eliminate
all overvoltages induced by an electromagnetic pulse, there are ways to
reduce them and strengthen the systems to be protected. In spite of the
amplitude of the phenomenon, protection can be provided by shielding
and ltering/surge protection adapted to NEMP.
Effects of overvoltages
Overvoltages have many types of effects on electronic equipment; in order of decreasing importance:
Destruction
Voltage breakdown of semiconductor junctions
Destruction of bonding of components
Destruction of tracks of PCBs or contacts
Destruction of triacs/thyristors by dV/dt.
Interference with operation
Random operation of latches, thyristors, and triacs
Erasure of memory
Program errors or crashes
Data and transmission errors
Premature ageing
Components exposed to overvoltages have a shorter life.
Industrial surges
This term covers phenomena caused by switching electric power sources
on or off.
Industrial surges are caused by:
Starting motors or transformers
Neon and sodium light starters
Switching power networks
Switch bounce in an inductive circuit
Operation of fuses and circuit-breakers
Falling power lines...
These phenomena generate transients of several kV with rise times in the
order of a few microseconds, disturbing equipment in networks to which
the source of disturbance is connected.
Electrostatic overvoltages (ESD)
Electrically, a human being has a capacitance ranging from 100 to 300
picofarads, and can pick up a charge of as much as 15kV by walking on
a carpet, then touch some conducting object and be discharged in a few
nanoseconds, with a current of about ten Amperes. All integrated circuits
(CMOS, etc.) are quite vulnerable to this kind of disturbance, which is generally eliminated by shielding and grounding.
The Surge Protection Devices (or SPD : this is a generic name for any
device to protect from voltage surges) is a recognized and effective solution for the overvoltage problem. For greatest effectiveness, however, it
must be chosen according to the risk and installed in accordance with the
applicable standards.
Standards
Because of the diversity and importance of transients, standards organizations have created specications for testing the effects of overvoltages
on equipment.
The phenomena were rst characterized and a series of standardized
waves created (1.2/50s voltage wave and 8/20s and 10/350s current
waveforms), then a number of standards dening surge arrester performance were issued, among them :
Surge Protectors for Low-Voltage installations :
NF EN 61643-11 (France)
VDE 0675-6-11 (Germany)
EN 61643-11 (Europe)
UL 1449 (USA)
IEC 61643-11 (International)
Surge Protectors for Telecom equipment :
IEC 61643-21 (International)
ITU-T recommendations K11, K12, K17, K20, K21, K36 (International)
UL 497 A/B (USA)
DIN RAIL AC
Surge Protectors
CITEL DS AC power Surge Protective Devices (SPD) are designed to meet all your
surge protection needs for any low voltage installation.
These DIN rail mounted surge protectors are easy to install in any standardized
distribution panel or control cabinets. The SPDs are equipped with a thermal disconnection device and provide real-time fault indicators thus allowing complete
operational safety.
DS surge protectors are available with several protection circuits to comply with
even the most demanding installations and standards compliance requirements.
CITEL AC power surge protectors offer three levels of surge protection capacity that
correspond to the different IEC or EN classes, i.e. Class I, II and III.
Standards
Operating principle
Product standards :
These documents address the type of tests the SPD manufacturer
must apply on its devices :
- Europe : EN 61643-11
- Germany : VDE 0675-6-11
- International : IEC 61643-11
- USA : UL1449-3ed
- France : NF EN 61643-11
Installation standards :
These documents give the main information about AC power surge
protectors and its proper installation:
- International : IEC 61643-12 guide
- Germany : VDE 0675-6-12
- USA : IEEE C62-41
- France : UTE C15-443 guide
Selection standards :
They dene the basic rules to select the surge protector in accordance with the general electrical code :
- Germany : DIN VDE 0100 part 443 and 534
- International : IEC 60364-4-433 and 5-534
- France : NF C 15-100 sect. 443 and 534
V : Varistor
Ft : Thermal fuse
t : Thermal disconnection
C : Remote signaling contact
VG technology by CITEL
In order to improve the surge protection efciency, CITEL has developed a patented technology which combines a high energy varistor
(MOV) network and a specic gas tube (GSG). This specialized circuit
incorporated in the VG Type 1+2+3 surge protectors (DS150VG,
DS250VG, DUT250VG) or Type 2+3 (DS40VG) can achieve better performance of:
- Protection level,
- Life duration (due to the suppression of leakage current),
- Continuous operation and power quality (no follow current)
- End of life behavior.
For instance, these features allow it to reach, even with a single stage
of surge protection, the same protection efciency as a double stage
association (Type 1, Type 2 and Type 3 SPDs) (see page 13).
Level of protection - Up
Maximum residual voltage of the surge protector during an 8/20s
current waveform shot (at the maximum of the In or Iimp declared
current) or during a 1,2/50s @ 6kV voltage waveform shot test (if
required)..
Residual Voltage - Up-in
Residual voltage of the surge protector during an 8/20s current
waveform shot at a determined value (In or Iimp). This value is lower
than the Up Protection level for all the VG type surge protector.
Short circuits capability - Isccr
The surge protection and its associated disconnector (Fuse) are
tested at a maximal short circuit current value (ex: 25kA) : This Isccr
value needs to be higher than the short circuit value of the network at
the installation point.
Follow on current extinction capability - I
This criteria is only devoted to surge protection using the air gap
technology:once they have red, these surge protectors conduct part
of the network current (follow on current) and need to interrupt it.
This behavior does not concern low voltage surge protector using
Metal Oxide Varistor technology.
DS250
DS70R
DS40
DS10
DS215
L/NL
Type 1
/N
Type 2
Type 2 or 3
Disconnection devices
Maintenance
Safety remote
signaling
Connection
Conductor or Bus
Voltage
keying
DIN mounting
Din rail format
Built-in
disconnector
Pluggable design
The design of some DS surge protectors (DS10, DS40, DS240, DS70R,
DS130R) is based on the use of a pluggable module that plugs into
a matching receptacle. This makes replacement, and checking
very easy without impairing the protection function. On multipolar
surge protectors, the possibility of replacing a single pole makes
rehabilitating a surge protector less expensive.
The plug-in module is identied with a color label in relation with the
type (Black = Type 1 ; Red = Type 2 ; Blue = Type 2 low power or Type 3)
and are keyed for operating voltage, in order to avoid misapplications.
Signaling
DS surge protectors are equipped with a failure indicator (mechanical
or light) linked to the internal thermal disconnector : in case of safety
disconnection, the indicator will switch on and the SPD must be
replaced.
Remote Signaling
Most DS surge protectors are available in remote signaling
versions. This feature, which allows remote checking of the status
of the surge protector, is especially important when the products are
hard to reach or unsupervised.
The system consists of an auxiliary changeover contact that is
activated if the surge protector module changes status.
This lets the user monitor :
the good operation of the SPD
the presence of the plug-in modules (if any)
the end of life (disconnection) of the surge protector.
The remote signaling version allows the choice of signaling system
appropriate to the installation (light, buzzer, automation, modem
transmission...).
Indicators
Pluggable
Identification of version
10
Location
DS surge protectors are installed as follows, according to their types :
Type 1 or Heavy duty : at the origin of the installation, in a
separate box or on the main electrical panel, for efcient discharge of
partial lightning currents.
Type 2 or Primary : at the origin of the installation, on the main
electrical panel, in order to eliminate impulses currents as fast as
possible and thereby avoid coupling.
Type 2 (or Type 3) or Secondary : on the secondary panel, near
the sensitive equipment, to limit ringing and improve the level of
protection.
Wiring
Since lightning surges are essentially common-mode phenomena,
DS surge protectors are connected mainly in common mode (between
the active conductors and ground).
Some recommendations call for additional differential-mode
protection (between phase and neutral). For these applications,
CITEL offers specic versions, using a gas tube base module for the
Neutral to Ground (common mode) protection: this type of installation
is called a CT2 connection in IEC 60364 standard, is used in surge
protectors such as DS44-230/G.
L1
L2
L3
N
DS44-400
L1
L2
L3
N
DS44-230/G
11
Installation
DS surge protectors are connected in parallel on the AC network and
must be equipped with external fuses (or breakers) for short-circuit
protection (see paragraph Disconnection devices).
The total length of connection wires to AC network must be lower
than 0.5 m in order not to increase the protection level (Up) provided
by the SPD.
Wiring is made by screw connections. On some models, a
distribution bus can be used.
The protection wire coming from the SPD must be connected to the
bonding bar of the electrical panel. Paralleling the protection wire
with phases conductors must be avoided.
Disjoncteur
type S
Type S or delayed
fault breaker
ouground
retard
AC network
Installation
Fusible
Fuses
or ou
circuit-breaker
Disjoncteur
3-Phase
surge protector
DS44S-230/G
Remote signaling
of disconection
Main
Barrette
earthing
principale
debarTerre
L1
L2
L3
Longueur
totale
total length
of
des
theconducteurs
conductor
<<0,5
m
0,5 m
to ground
network
12
Overview
Several technologies exist on the market for surge protection or
power network:
Metal Oxide Varistor (MOV)
Air Gap + Trigger
MOV + Gas-lled Spark Gap (GSG)
VG technology
This technology is the exclusive and patented technology of CITEL
based on the use of specic types of Gas tubes: GSG. These components, the result of over 75 years of experience in the gas discharge
tube eld, have a behavior adapted to the power network and provide robustness and working stability: their association with varistors
combines the advantages of both technologies.
Advantages of VG Technology
versus other technologies (specifically the triggered spark gap)
13
4. No follow current
Unlike to Air Gap technologies, VG Technology does not create any follow on current.
VG ->Increased service continuity (No tripping of the upstream overcurrent protection device (OCP) during surge events)
Improvement of the network quality (no power line disturbances)
Easy selection
7. No ageing
During normal operation, in addition to transient events, varistors are always conducting a small amount of current.
This current is the result of working current (Ic) and leakage current (Ipe) and is due to the varistors connection to the
grounding system. This type of conduction can be stressful to the varistor over time, especially in dc power systems, and
cause the varistor to age prematurely.
Maximum life
Conclusion :
CITEL Surge Protectors based on VG technology offer the best level of efciency and reliability, conditions
essential for achieving the maximum performance of your protection system.
14
A6
CITELs line of AC power surge protectors is designed to cover all possible congurations in low voltage installations.
They are available in many versions, which differ in :
- Type or test class (1 , 2 or 3)
- Operating voltage (Uc)
- AC network conguration (Single/3-Phase)
- Discharge currents (Iimp, Imax, In)
- Protection level (Up)
- Protection technology (varistors, VG tecnology, lter)
- Features (differential mode, plug-in, remote signaling...).
The surge protection selection must be done following the local electrical code requirements (e.g. : minimum rating for In) and specic
conditions (e.g. : high lightning density).
SPD
Location
CITEL
Installation equipped
with LPS or could be
hit by lightning
Type 1+2
Type 1+2+3
Origin of the
installation origin
(Panel or main
switchboard)
DS130R
DS130VG
DS250VG
DUT250VG
DS250E
Installation without
LPS
Type 2
Type 2+3
Secondary protection
(downstream primary
SPD)
Type 2
(or Type 3)
230/400V
120/208V
AC system
TT
TN
IT
TN
Voltage Uc
255 V
255 V
400 V
150 V
Voltage UT
400 V
335 V
175 V
Example of
CITEL product
DS42-230/G
DS42-230
DS42-400
DS42-120
Choosing Iimp
The impulse current Iimp is dened for Type 1 SPD. The minimum
rating for Iimp is 12.5 kA by pole, following IEC 60364-5-534 . This
level is adapted to the real phenomenon.
CITEL proposes, in its Type 1 SPD range, 2 levels of Iimp current :
12.5 and 25 kA.
Configuration
Iimp
CITEL
25 kA
DS250VG
DS250E
DUT250VG
12.5 kA
DS130VG
DS130R
In
CITEL
> 20 kA
DS70R
10-20 kA
DS40, DS40VG
DS240, DS440
5 kA
DS10
DS215, DS415
Conditions
AC network conguration
DS surge protectors are available for single, 3-Phase and 3-Phase +
neutral AC networks.
15
Recommended Up
230/400 V
120/208 V
AC network
AC network
2.5 kV max.
1.5 kV max.
2.5 kV
1.5 kV
1.5 kV
0.8 kV
A relevant choice of the SPD technology, as well as the use of coordination diagram can help to improve the protection level.
Coordination by conductor
L2 < 10 m
L1
L
L1
P3
L2 < 10 m
L
L1
L3
Coordination by inductor
P2
L2
P2
L2
L3
P3
16
Main swichtboard
D
L
N
L
N
L
N
Type 1 surge
protector
DS252
Type 2 Surge
protector
DS72R, DS42 and
DS12 series
Remote signaling
of disconnection
PE
Busbar
Diagram
Main swichtboard
Remote signaling
of disconnection
PE
Ground
Ground
L1
L2
L3
L1
L2
L3
Diagram
Main swichtboard
Main swichtboard
L1
L2
L3
Type 1 surge
protector
DS253
Remote signaling
of disconnection
PEN
Busbar
Type 2 surge
protector
DS73R, DS43 and
DS13 series
Remote signaling
of disconnection
PEN
Ground
Ground
D
L1
L2
L3
N
L1
L2
L3
N
L1
L2
L3
N
Diagram
Main swichtboard
Main swichtboard
Remote signaling
of disconnection
PE
Busbar
17
Type 2 surge
protector
DS70R, DS40 and
DS10 series
Type 1
Surge protector
DS254
Ground
Remote signaling
of disconnection
PE
Ground
P : Surge protector
D : Circuit breaker
F : Associated disconnector
(fuse or circuit-breaker)
Diagram
Main swichtboard
Main swichtboard
L1
N
L
N
L1
N
Type 1 surge
protector
DS252/G
Type 2 Surge
protector
DS42/G
DS12/G
Remote signaling
of disconnection
Remote signaling
of disconnection
PE
PE
Ground
Busbar 1+1
Ground
10
Main swichtboard
Main swichtboard
L1
L2
L3
N
L1
L2
L3
N
L1
L2
L3
N
Diagram
F
P
Type 2 surge
protector
DS44/G
DS14/G
Type 1 surge
protector
DS254/G
Remote signaling
of disconnection
PE
Ground
Busbar 3+1
11
Remote signaling
of disconnection
PE
Ground
Diagram
Main swichtboard
L1
L2
L3
N
L1
L2
L3
N
F
P
Type 1
surge protector
DUT250VG
PE
Ground
P : Surge Protector
G : Surge protector with GDT
D : Circuit breaker
F : Associated disconnector
(fuse or circuit-breaker)
18
12
Diagram
D
L
N
L
N
Remote signaling
of disconnection
Type 2
Surge protector
DS240/G
DS240/G
DS215/G
PE
Ground
13
Diagram
D
L1
L2
L3
N
L1
L2
L3
N
P
Type 2 Surge
protector
DS440/G
DS415/G
DS440/G
DS415/G
Remote signaling
of disconnection
PE
Ground
14
Diagram
D
L
N
L
N
P
RFI
DS-HF
Type 2 Surge
Protector+Filter
DS-HF
PE
Ground
19
P : Surge protector
RFI : RFI lter
D : Breaker
F : Associated disconnector
(fuse or circuit-breaker)
Associated fuses
To comply with standards and safety, the AC surge protectors must
be protected against a possible end of life in short-circuit : the user
must install on each SPD branch, a protection against short circuit
current (fuses or breaker).
The rating of this fuse is given by the SPD manufacturer in the product datasheet and installation instructions. The choice of this rating
depends of 2 criteria:
- Withstand of the short-circuit current test in the IEC 616431 standard : the fuse must cut safely the short-circuit current
before an harsh destruction of the SPD.
- Withstand of the discharge currents (In or Imax) : the fuse
must be able to conduct the discharge current of the SPD
without blowing.
Fuses on each
branch, rating and
type in the SPD
installation
instructions.
L1
L2
L3
CITEL has selected some fuses and DIN rail holders to t with his
SPD range. The fuses are equipped with failure indicators to check
easily their opening and the holders can be supplied with or without
contact for remote signal of fuse status.
Dimensions
Fuse P/N
125 A gG
22x58 mm
6062 0125
100 A gG
22x58 mm
6062 0100
50 A gG
22x58 mm
6062 0050
20 A gG
22x58 mm
6062 0020
Number of poles
with remote
signaling contact
withou remote
signaling contact
1 pole
5603 5011
5603 5001
2 poles
5603 5012
5603 5002
3 poles
5603 5013
5603 5003
4 poles
5603 5016
5603 5006
Fuse holders
20
TGBT
L1
L2
L3
N
F
F
Type 1 Surge
protector
DS250 series
Type 2 surge
protector
DS40 series
Coordination inductors
PE
Ground
Diagram
L1
L2
L3
N
F
P
21
F
P
P : Surge protector
D : Breaker
F : Associated disconnector
(fuse or circuit-breaker)
L : Coordination inductor
L1
L2
L3
N
Type 2 surge
protector
DS40 series *
Type 1 Surge
protector
DS250VG series
PE
L1
L2
L3
N
F
P
F
P
P : Surge protector
D : Breaker
F : Associated disconnector
(fuse or circuit-breaker)
*optional
22
23
5 - The unavailability of the electrical network could have consequences on human safety.
Surge Protector mandatory or risk analysis required.
Ng < 2.5
Ng > 2.5
Mandatory
(Type 1)
Mandatory
(Type 1)
No
mandatory*
Mandatory
(Type 2)
Non
mandatory*
Non
mandatory*
Conclusion
Depending on the countries, AC surge protectors could be recommended or mandatory in relation with the external conditions (type
of network and lightning threat). Risk assessment methods are also
available to determine more accurately the need of surge protection.
In any case, all the present electrical installations are crowded with
sensitive devices, installing properly selected surge protectors is becoming more and more critical.
Catgories of location
Current
8/20 s
Indoor installation
6 kV
0,5 kA
Entry installation
6 kV
3 kA
Outdoor installation
low exposure
6 kV
6 kA
Outdoor installation
high exposure
10 kV
10 kA
ANSI/IEEE Guide:
ANSI/IEEE publishes different informative guides regarding the risk
of transient overvoltages to low voltage networks (IEEE C62.41.1), the
surge environment and types of transients (IEEE C62.41.2) as well as
the method for testing equipment against transients that are connected to the low voltage network (IEEE C62.45).
Another important guideline detailing the installation of SPDs is called IEEE C62.72
24
A pluggable design
The design of most DS surge protectors is based on the use of a module to be plugged into a
matching base.
This makes replacement and checking very easy without impairing your protection.
For multipole surge protectors, the possibility of replacing a single pole makes repairing a
surge protector less expensive.
The plug-in module is identied with a color label in relation with the type (black = Type 1 ;
red = Type 2 ; blue = low power Type 2 or Type 3) and are keyed for operating voltage, in order
to avoid misapplications
DSDT16
Option for mounting in series
Plug-in module
All modules are marked with
characteristics for major
approval stamps.
Application field
25
Signaling
Identified connections
Spare module
Module codification
Remote signaling
Less wiring thanks to a single
remote signaling connector for
all poles
Mistake-free replacement
thanks to an explicit and
mechanical codication for the
different operating voltages.
26
Type 1+2 and Type 1+2+3 surge protectors are heavy duty devices, designed to be installed at the origin of the AC installations equipped
with LPS (Lightning Protection System). They are necessary to protect
sensitive equipment connected to AC network against direct and indirect effects of lightning. Following the different national electrical
codes, these SPDs can be recommended or mandatory.
27
Iimp by pole
Range
Description
DS250VG
1-pole reinforced
surge protector VG Technology
25 kA
29
DS250E
1-pole reinforced
surge protector VG Technology
25 kA
31
DUT250VG
25 kA
Compact
Very high energy
34
DS130VG
12,5 kA
Compact
Pluggable
35
DS130R
12,5 kA
Compact
Pluggable
37
(10/350 s)
Characteristics
Page
28
DS250VG series
25 kA on 10/350 s impulse
Low voltage Up
Optimized to TOV
DS250VG-300
VDE approved
Characteristics
(in mm)
67
36
DS250VG-300
DS250VG-120
AC Network
Connection mode
AC system
Max operating voltage
TOV withstand
Operating current
Uc
UT
Ic
230/400V
L/N, L/PE
TT, TN
255 Vac
450 vac
none
120/208V
L/N, L/PE
TT, TN
150 Vac
230 Vac
none
If
In
none
30kA
none
30 kA
Imax
70 kA
70 kA
Iimp
25 kA
25 kA
Uoc
20 kV
20 kV
Up-in
Up
Isccr
1.1 kV
1.5 kV
50000 A
0.7 kV
1 kV
Leakage current at Uc
90
Follow current
Nominal discharge current
15 x 8/20 s impulses
10.6
50000 A
L/N L/N
internal
Fuse type gG - 250 A max. (see Note 1)
Type S or delayed
Mechanical characteristics
MI
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
Ft
t
GSG
C
14
11
12
see diagram
by screw terminals : 6-35 mm / by bus
1 mechanical indicator
output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL 94-V0
Standards compliance
IEC 61643-11
EN 61643-11
NF EN 61643-11
UL1449 ed.3
International
Europe
France
USA
Part Number
DS250VG-300
DS250VG-120
2577
2787
Note 1: Rating in compliance with nominal discharge current. In order to increase service continuity, higher rating can be
used (up to 250 A). For further information, please consult product instructions.
29
DS25x VG-xxx/G
= CT1 conguration (common mode)
G = CT2 conguration (common and diferential mode)
Operating voltage
VG = VG Technology
Number of protected poles (1,2,3,4)
DS253VG-300
Dimensions - Diagram
1
2
72
72
108
2
L/N (L/N)
MI
Ft
t
L/N (L/N)
MI
Ft
Ft
t
(L)
GSG
L3
MI
(L3)
MI
Ft
t
GSG
GSG
4
5
(L2)
Ft
t
GSG
GSG
L2
MI
Ft
GSG
L1 (L1)
MI
GSG
5
L1 (L1)
L2
MI
Ft
t
(L2)
MI
Ft
t
GSG
L3
(L3)
MI
Ft
t
GSG
(N)
L1 (L1)
MI
Ft
t
Ft
t
GSG
GSG
(L2)
L3
MI
Ft
t
GSG
L2
MI
(L3)
MI
Ft
t
GSG
GSG
GSG
144
144
Part number
Network
AC system
DS254VG-300/G
2756
230/400 V 3-phase+N
TT-TNS
DS254VG-120/G
2757
120/208 V 3-phase+N
TT-TNS
DS254VG-300
3713
230/400 V 3-phase+N
TNS
DS254VG-120
3722
120/208 V 3-phase+N
TNS
DS253VG-300
3896
400 V 3-phase
TNC
DS253VG-120
3959
208 V 3-phase
TNC
DS252VG-300/G
3403
TT-TN
DS252VG-120/G
3960
TT-TN
DS252VG-300
3469
TN
DS252VG-120
3950
TN
diferential
References
common
Protection
mode
Iimp
total
Up
L/PE
Up
L/N
100 kA
1.5 kV
1.5 kV
100 kA
1.5 kV
1 kV
100 kA
1.5 kV
100 kA
1 kV
75 kA
1.5 kV
75 kA
1 kV
50 kA
1.5 kV
1.5 kV
50 kA
1.5 kV
1 kV
50 kA
1.5 kV
50 kA
1 kV
Diagram
5
4
3
2
1
30
DS250E series
DS250E-300
Characteristics
(in mm)
67
36
DS250E-400
DS250E-300
DS250E-120
Network
Connection mode
AC system
Max. operating voltage
TOV withstand
Operating current
Uc
UT
Ic
230/400V
L/PE
IT, TT
440 Vac
770 Vac
< 2 mA
230/400V
L/N
TT,TN
330 Vac
440 Vac
< 2 mA
120/208V
L/N, L/PE
TT, TN
150 Vac
230 Vac
< 2 mA
If
In
none
50 kA
none
70 kA
none
70 kA
Imax
140 kA
140 kA
140 kA
Iimp
25 kA
25 kA
25 kA
Up
2.5 kV
50000 A
2.5 kV
50000 A
1 kV
50000 A
Leakage current at Uc
90
Follow current
Nominal discharge current
15 x 8/20 s impulses
10.6
Mechanical characteristics
L/N L/N
MI
internal
Fuses type gG - 125 A (see Note 1)
Type S or delayed
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
Ft
t
See diagram
by screw terminals : 6-35 mm / by bus
3 mechanical indicators
output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
C
14
11
12
IEC 61643-11
EN 61643-11
NF EN 61643-11
UL1449 ed.3
International
Europe
France
USA
Part Number
DS250E-400
DS250E-300
DS250E-120
3731
2730
3106
Note 1: Rating in compliance with NF C15-100 art. 534.1.3.5. In order to increase service continuity, higher rating can be used (up to 250 A).
For further information, please consult product instructions.
31
DS25x E-xxx/G
= Conguration CT1 (common mode)
G = Conguration CT2 (common and differential mode)
Operating voltage
E = Varistor technology
Number of protected poles (2, 3 o 4)
DS254E-300/G
Dimensions - Diagram
1
72
72
108
L/N (L/N)
MI
Ft
t
L/N (L/N)
MI
Ft
(L)
L1 (L1)
MI
Ft
t
L2
MI
Ft
t
(L2)
L3
MI
Ft
t
(L3)
MI
Ft
t
GSG
5
L1 (L1)
L2
MI
Ft
t
(L2)
L3
MI
Ft
t
(L3)
MI
Ft
t
(N)
L1 (L1)
MI
Ft
t
L2
MI
Ft
t
(L2)
L3
MI
Ft
t
(L3)
MI
Ft
t
GSG
144
Part number
Network
DS254E-300/G
3411
230/400 V 3-phase+N
TT-TNS
DS254E-120/G
3831
120/208 V 3-phase+N
TT-TNS
DS254E-400
3732
230/400 V 3-phase+N
IT-TNS
DS254E-300
3371
230/400 V 3-phase+N
TNS
DS254E-120
3961
120/208 V 3-phase+N
TNS
DS253E-400
3939
400 V 3-phase
IT-TNC
DS1253E-300
3350
400 V 3-phase
TNC
DS253E-120
3887
208 V 3-phase
TNC
DS252E-300/G
3404
TT-TN
DS252E-120/G
3409
TT-TN
DS252E-400
3952
IT-TN
DS252E-300
3962
TN
DS252E-120
3951
TN
Protection
mode
diferential
Reference
AC
system
common
144
Iimp
total
Up
L/PE
Up
L/N
100 kA
2.5 kV
2.5 kV
100 kA
1.5 kV
1 kV
100 kA
2.5 kV
100 kA
2.5 kV
100 kA
1 kV
75 kA
2.5 kV
75 kA
2.5 kV
75 kA
1 kV
50 kA
2.5 kV
2.5 kV
50 kA
1.5 kV
1 kV
50 kA
2.5 kV
50 kA
2.5 kV
50 kA
1 kV
Diagram
32
DS250VG-690 series
In : 30 kA
Iimp : 25 kA
Low voltage Up
DS250VG-690
DS253VG-690
Dimensions - Diagram
Characteristics
(in mm)
DS250VG-690
90
70
(L)
Uc
UT
Ic
DS250VG-690
400/690 V
1-Pole
760 Vac
1350 Vac
none
DS253VG-690
400/690 V
3-phase
760 Vac
1350 Vac
none
If
In
none
30 kA
none
30 kA
Imax
100 kA
100 kA
Iimp
25 kA
25 kA
Uoc
20 kV
20 kV
Itotal
75 kA
Up
Isccr
4 kV
50000 A
4 kV
50000 A
Leakage current at Uc
90
Follow current
Nominal discharge current
15 x 8/20 s impulses
MI
Thermal disconnector
Fuses
Installation ground fault breaker (if any)
(L)
Mechanical characteristics
Ft
t
internal
Fuses type gG - 125 A (see Note 1)
Type S or delayed
GSG
C
14
11
12
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
See diagram
by screw terminal : 6-35 mm (50mm exible)
1 mechanical indicator/pole
output on changeover contact
symetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standard compliance
IEC 61643-11
EN 61643-11
UL1449 ed.3
International
Europe
USA
Part number
DS250VG-690
DS253VG-690
-3957
Note 1: Rating in compliance with nominal discharge current. In order to increase service continuity, higher rating can be used . For
further information, please consult product instructions.
33
DUT250VG-300/G
Low voltage Up
No Follow current
DUT250VG-300G
Characteristics
(in mm)
72
67
DUT250VG-300/G
AC Network
AC system
Protection modes
Max. operating voltage
Temporary overvoltage withstand
Operating current
Uc
UT
Ic
3-Phase 230/400V
TT, TN
L/N and N/PE
255 Vac
450 Vac
none
If
In
none
40 kA
Imax
100 kA
Uoc
20 kV
Iimp
25 kA
Itotal
50 kA
Up-in
Up
1.1 kV
1.5 kV
50000 A
Leakage current at Uc
Follow current
Nominal discharge current
90
15 impulses - 8/20s
L2
MI
Ft
L3
MI
t
GSG
Ft
MI
t
GSG
GSG
GSG
Thermal disconnector
Required external fuses
Installation ground fault breaker
internal
Fuses type gG - 125 A max. (see Note 1)
Type S or delayed
Mechanical characteristics
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
see diagram
by screw terminals : 6-35 mm
red light indicators
none
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
IEC 61643-11
NF EN 61643-11
EN 61643-11
UL1449 ed.3
International
France
Europe
USA
Part number
DUT250VG-300/G
3414
Note 1: Rating in compliance with NF C15-100 art. 534.1.5.3. In order to increase service continuity, higher rating can be used.
For further information, please consult product instructions.
34
DS130VG series
In : 20 kA
Iimp : 12,5 kA
Pluggable module
Optimized to TOV
DS132VG-120
Characteristics
(in mm)
82
9
L/N
DS131VG-230
DS131VG-120
AC network
Max. operating voltage
TOV withstand
Operating current
Uc
UT
Ic
230/400V
255 Vac
450 Vac
none
120/208V
150 Vac
230 Vac
none
If
In
none
20 kA
none
20 kA
Imax
50 kA
50 kA
Iimp
12.5 kA
12.5 kA
Uoc
20 kV
20 kV
Up-in
Up
Isccr
0.6 kV
1.25 kV
25000 A
0.4 kV
1.25 kV
25000 A
Leakage current at Uc
Follow current
Nominal discharge current
15 x 8/20 s impulse
90
44
18
74.8
Associated disconnectors
Thermal disconnector
Fuses
Installation ground fault breaker
12
14
11
Mechanical characteristics
L/N
MI
Ft
t
internal
Fuses type gG - 125 A (see Note 1)
Type S or delayed
GSG
Dimensions
Connection
Disconnection indicator
Remote signaling
Mounting
Operating temperature
Protection class
Housing material
see diagram
by screw terminals : 2.5-25 mm / by bus
1 mechanical indicator
output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standard compliance
NF EN 61643-11
IEC 61643-11
EN 61643-11
UL1449 ed.3
France
International
Europe
USA
Part number
DS131VG-230
DS131VG-120
571551
571651
Note 1: Rating in compliance with NF C15-100 art. 534.1.5.3. In order to increase service continuity, higher rating can be used
(160A). For further information, please consult product instructions.
35
DS13x VGS-xxx/G
= Conguration CT1 (common mode)
G = Conguration CT2 (common and differential mode)
Operating voltage
S = Remote signal option
Number of protected poles (2, 3 o 4)
DS134VG-230/G
82
2
LN
LN
LN
L1
L2
MI
Ft
L3
LN
MI
Ft
L1
MI
Ft
t
Ft
MI
t
GSG
GSG
90
L3
MI
Ft
t
GSG
GSG
GSG
L2
MI
Ft
GSG
GSG
C
14
11
12
14
11
12
14
11
12
9
44
36
36
54
74
L1
L2
MI
Ft
t
Ft
L2
L3
L1
L2
L3
MI
t
GSG
L1
L3
Ft
NL
MI
Ft
t
GSG
1L
MI
t
t
GSG
Ft
3N
MI
t
GSG
GSG
Ft
MI
t
GSG
GSG
GSG
C
14
11
12
14
11
12
72
2L
MI
Ft
72
Part number
Network
AC system
DS134VG-230/G
571564
230/400 V 3-phase+N
TT-TNS
DS134VG-120/G
571664
120/208 V 3-phase+N
TT-TNS
DS134VG-230
571554
230/400 V 3-phase+N
TNS
DS134VG-120
571654
120/208 V 3-phase+N
TNS
DS133VG-230
571563
400 V 3-phase
TNC
DS133VG-120
571663
208 V 3-phase
TNC
DS132VG-230/G
571552
TT-TN
DS132VG-120/G
571652
TT-TN
DS132VG-230
571562
TN
DS132VG-120
571662
TN
diferential
References
common
Protection
mode
Iimp
total
Up
L/PE
Up
L/N
50 kA
1.5 kV
1.25 kV
50 kA
1.5 kV
1.25kV
50 kA
1.25 kV
50 kA
1.25 kV
37,5 kA
1.25 kV
37,5 kA
1.25 kV
25 kA
1.5 kV
1.25kV
25 kA
1.5 kV
1.25kV
25 kA
1.25 kV
25 kA
1.25 kV
Diagram
5
4
3
2
1
36
DS130R series
In : 20 kA
Iimp : 12,5 kA
DS131R-400
Characteristics
(in mm)
82
9
L/N
DS131R-400
DS131R-280
DS131R-230
DS131R-120
AC network
Max. operating voltage
TOV withstand
Operating current
Uc
UT
Ic
230/400V
440 Vac
770 Vac
< 1 mA
230/400V
280 Vac
440 Vac
230/400V
255 Vac
440 Vac
< 1 mA
120/208V
150 Vac
230 Vac
< 1 mA
If
In
none
20 kA
none
20 kA
none
20 kA
Imax
50 kA
50 kA
50 kA
Iimp
12.5 kA
12.5 kA
12.5 kA
12.5 kA
Up
Isccr
1.7 kV
25000 A
1.3 kV
25000 A
1.3 kV
25000 A
0.9 kV
25000 A
Leakage current at Uc
Follow current
Nominal discharge current
15 x 8/20 s impulse
90
< 1 mA
none
20 kA
50 kA
Associated disconnectors
44
18
74.8
Thermal disconnector
Fuses
Installation ground fault breaker
internal
Fuses type gG - 125 A (see Note 1)
Type S or delayed
12
11
L/N
14
Mechanical characteristics
MI
Ft
t
Dimensions
Connection
Disconnection indicator
Remote signaling
Mounting
Operating temperature
Protection class
Housing material
see diagram
by screw terminals : 2.5-25 mm / by bus
1 mechanical indicator
output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic PEI UL94-5VA
Standard compliance
IEC 61643-11
EN 61643-11
NF EN 61643-11
UL1449 ed.3
International
Europe
France
USA
Part number
V : High energy MOV
Mi : Disconnection indicator
Ft : Thermal fuse
t : Thermal disconnection mechanism
C : contac for remote signal
37
DS131R-400
DS131R-280
DS131R-230
DS131R-120
571401
571101
571501
571601
Note 1: Rating in compliance with NF C15-100 art. 534.1.5.3. In order to increase service continuity, higher rating can be used (up to 160 A).
For further information, please consult product instructions.
DS13x RS-xxx/G
= Conguration CT1 (common mode)
G = Conguration CT2 (common and differential mode)
Operating voltage
S = Remote signal option
Number of protected poles (2, 3 o 4)
DS134R-230/G
Dimensions - Diagram
1
82
2
LN
LN
L1
L2
2
L/N
L/N
L1
L2
L3
L3
MI
Ft
t
MI
Ft
MI
Ft
MI
Ft
90
MI
Ft
t
MI
Ft
t
GSG
C
14
11
12
14
11
12
14
11
12
9
44
36
54
36
74.8
4
L1
L2
L3
L1
L3
L2
MI
Ft
L1
L2
L3
L1
L2
L3
Ft
t
MI
Ft
MI
Ft
MI
MI
Ft
t
Ft
t
MI
Ft
MI
GSG
14
11
12
14
11
12
72
72
Part number
Network
AC system
DS134R-280/G
571124
230/400 V 3-phase+N
TT-TNS
DS134R-230/G
571524
230/400 V 3-phase+N
TT-TNS
DS134R-120/G
571624
120/208 V 3-phase+N
TT-TNS
DS134R-400
571404
230/400 V 3-phase+N
IT-TNS
DS134R-280
571104
230/400 V 3-phase+N
TNS
DS134R-230
571504
230/400 V 3-phase+N
TNS
DS134R-120
571604
120/208 V 3-phase+N
TNS
DS133R-400
571403
400 V 3-phase
IT-TNC
DS133R-280
571103
400 V 3-phase
TNC
DS133R-230
571503
400 V 3-phase
TNC
DS133R-120
571603
208 V 3-phase
TNC
DS132R-280/G
571122
TT-TN
DS132R-230/G
571522
TT-TN
DS132R-120/G
571622
TT-TN
DS132R-400
571402
IT-TN
DS132R-280
571102
TN
DS132R-230
571502
TN
DS132R-120
571602
TN
common
Rfrences
diferential
Protection
mode
Iimp
total
Up
L/PE
Up
L/N
50 kA
1.5 kV
1.3 kV
50 kA
1.5 kV
1.3 kV
50 kA
1.5 kV
0.9 kV
50 kA
1.7 kV
50 kA
1.3 kV
50 kA
1.3 kV
50 kA
0.9 kV
37.5 kA
1.7 kV
37.5 kA
1.3 kV
37.5 kA
1.3 kV
37.5 kA
0.9 kV
25 kA
1.5 kA
1.3 kV
25 kA
1.5 kV
1.3 kV
25 kA
1.5 kV
0.9 kV
25 kA
1.7 kV
25 kA
1.3 kV
25 kA
1.3 kV
25 kA
0.9 kV
Diagram
38
39
Arresters tested and found Type 3 are intended to be installed near sensitive
equipment, in coordination with type 2 arrester installation head.
Note: the installation guide UTE C15-443 and Articles 443 and 534 of the NF C15-100 only
consider SPDs Type 1 and Type 2.
CITEL surge arresters Type 2 are based on the use of varistors. Version DS40VG uses VG technology.
Characteristics
DS70R
Reinforced
surge
protector
70 kA
Type 2
High energy
pluggable
41
DS40VG
Surge
protector
VG Technology
40 kA
Type 2 + 3
Very high efciency
pluggable
43
DS40
Standard
surge
protector
40 kA
Type 2
pluggable
45
DS10
Secondary
surge protector
10 kA
Type 2 or 3
pluggable
47
Range
Description
Page
Range
Description
Imax by
pole
Characteristics
DS240
DS215
Single phase
surge
protector
40 kA
15 kA
Single phase
Compact
Pluggable
49
51
DS440
DS415
3-phase+N
surge
protector
40 kA
15 kA
3-phase
Compact
Pluggable
50
52
DS98
Single phase
surge
protector
10 kA
Single phase
Compact
Monobloc
53
DS40HF
DS-HF
RFI lter
surge protector
10 to
40 kA
RFI lter
54
55
DS2x0-DC
DC surge
protector
20 to
40 kA
DC network
Compact
Pluggable
Page
56-57
40
DS70R series
In : 30 kA
Imax : 70 kA
UL1449 ed.3
DS71R-400
Characteristics
(in mm)
67
DS71RS (1 pole)
L/N
DS71R-400
DS71R-230
DS71R-120
Network
Max. operating voltage
Temporary overvoltage withstand
Operating current
230/400V
440 Vac
770 Vac
< 1 mA
230/400V
255 Vac
440 Vac
< 1 mA
120/208V
150 Vac
230 Vac
< 1 mA
If
In
none
30 kA
none
30 kA
none
30 kA
Imax
70 kA
70 kA
70 kA
Up
1.8 kV
1.4 kV
1.2 kV
25000 A
1.4 kV
1 kV
0.9 kV
25000 A
1 kV
0.7 kV
0.6 kV
Leakage current at Uc
Follow current
Nominal discharge current
Uc
UT
Ic
15 x 8/20 s impulses
90
9
44
18
60.8
25000 A
internal
Fuses type gG - 100 A (see Note 1)
Type S or delayed
12
14
L/N
11
Mechanical characteristics
MI
Ft t
Ft
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
see diagram
by screw terminals : 2.5-25 mm / by bus
2 mechanical indicators by pole
Option DS70RS - output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
EN 61643-11
IEC 61643-11
NF EN 61643-11
UL1449 ed.3
Europe
International
France
USA
Part number
V : High energy varistor
Ft : Thermal Fuse
C : Remote signaling contact
t : Thermal disconnection system
41
DS71R-400
DS71R-230
DS71R-120
321401
3214011
321601
Note 1: Rating in compliance with NF C15-100 art.534.1.3.5. In order to increase service continuity, higher rating can be used (up to
160 A). For further information, please consult product instructions.
DS7x RS-xxx
Operating voltage
S = Remote signal option
Number of protected poles (2, 3 or 4)
DS74R-230
Dimensions - Diagram
1
/N
L1
L2
L3
L1
L2
L3
MI
Ft
MI
Ft
12
11
14
12
11
L3
MI
Ft
MI
Ft
Ft
MI
L2
14
12
11
14
12
L1
L/NL
11
2
LN
14
14
12
11
67
90
MI
Ft
Network
AC System
DS74R-400
491402
230/400 V 3-phase+N
IT-TT-TNS
DS74R-230
491502
230/400 V 3-phase+N
TNS
DS74R-120
491602
120/208 V 3-phase+N
TNS
DS73R-400
491403
400 V 3-phase
IT-TNC
DS73R-230
491503
400 V 3-phase
TNC
DS73R-120
491603
208 V 3-phase
TNC
DS72R-400
491401
IT-TT-TNS
DS72R-230
491501
TN
DS72R-120
491601
TN
differential
References
common
Protection
mode
Imax
total
Up
L/PE
280 kA
1.8 kV
280 kA
1.4 kV
280 kA
1 kV
210 kA
1.8 kV
210 kA
1.4 kV
210 kA
1 kV
140 kA
1.8 kV
140 kA
1.4 kV
140 kA
1 kV
Ft
t
12
11
14
12
11
L3
Part
number
L2
14
12
11
14
L1
12
72
54
11
36
14
44
60.8
MI
Ft
t
MI
Ft
MI
Diagram
42
DS40VG series
DS41VG-120
In 20 kA
Imax 40 kA
Pluggable module
No ageing
Optimized to TOV
Characteristics
(in mm)
Rfrence CITEL
DS41VG-230
DS41VG-120
Network
Max. operating voltage
TOV withstand
Operating current
Uc
UT
Ic
230/400V
255 Vac
450 Vac
none
120/208V
150 Vac
230 Vac
none
If
In
none
20 kA
none
20 kA
Imax
40 kA
40 kA
Uoc
10 kV
10 kV
Up-in
Up
Isccr
0.8 kV
1.25 kV
25000 A
0.6 kV
1.25 kV
25000 A
Follow current at Uc
L/N
Follow current
Nominal discharge current
15 impulses - 8/20 s
90
Thermal disconnector
Fuses
Installation ground fault breaker
internal
Fuses type gG - 50 A max. (see Note 1)
Type S or delayed
12
14
L/N
11
Mechanical characteristics
MI
Ft
t
GSG
Dimensions
Connection
Disconnection indicator
Remote signaling
Mounting
Operating temperature
Protection class
Housing material
See diagram
by screw : 2.5-25 mm / by bus
1 mechanical indicator
output on changeover contact
Symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic PEI UL94-5VA
Standard compliance
NF EN 61643-11
IEC 61643-11
EN 61643-11
UL1449 ed.3
GSG: Specic GDT
V: Varistor
Ft: Thermal fuse
C: Remote signaling contact
t: Disconnection system
Mi : Mechanical indicator
43
France
International
Europe
USA
Part number
DS41VG-230
331751
DS41VG-120
331651
Note 1: Rating in compliance with NF C15-100 art.534.1.3.5. In order to increase service continuity, higher rating can be used
(up to 160 A). For further information, please consult product instructions.
DS4x VGx-xxx/G
= CT1 conguration (common mode)
G = CT2 (common and differential mode)
Operating voltage
S = Remote signal option
Number of protected poles (2, 3 or 4)
DS44VG-230/G
Dimensions - Diagram
1
67
LN
L/NL
/N
LN
L1
L2
MI
Ft
L3
LN
MI
Ft
L1
MI
Ft
t
L3
MI
Ft
Ft
MI
GSG
GSG
GSG
L2
MI
Ft
GSG
GSG
GSG
GSG
90
14
5
L1
L2
MI
Ft
11
12
14
54
60.8
11
12
36
14
36
11
12
9
44
Ft
L3
MI
t
GSG
Ft
NL
MI
t
GSG
Ft
1L
MI
t
t
GSG
2L
MI
Ft
Ft
3N
MI
t
GSG
GSG
Ft
MI
t
GSG
GSG
GSG
L1
L2
L3
L1
L2
L3
14
11
12
14
11
12
72
Netword
AC system
DS44VG-230/G
461562
230/400 V 3-phase+N
TT-TNS
DS44VG-120/G
461662
120/208 V 3-phase+N
TT-TNS
DS44VG-230
461552
230/400 V 3-phase+N
TNS
DS44VG-120
461652
120/208 V 3-phase+N
TNS
DS43VG-230
461553
400 V 3-phase
TNC
DS43VG-120
461653
208 V 3-phase
TNC
DS42VG-230/G
461561
TT-TN
DS42VG-120/G
461661
TT-TN
DS42VG-230
461551
TN
DS42VG-120
461651
TN
Protection
mode
diferential
References
Part
number
common
72
Imax
total
Up
L/PE
Up
L/N
100 kA
1.5 kV
1.25 kV
100 kA
1.5 kV
1.25 kV
160 kA
1.25 kV
160 kA
1.25 kV
120 kA
1.25 kV
120 kA
0.9 kV
100 kA
1.5 kV
1.25 kV
100 kA
1.5 kV
1.25 kV
80 kA
1.25 kV
80 kA
1.25 kV
Diagram
5
4
3
2
1
44
DS40 series
In : 20 kA
Imax : 40 kA
UL1449 ed.3
DS41-230
Characteristics
(in mm)
CITEL part number
DS41S (1 pole)
Network
Max. operating voltage
Temporary overvoltage withstand
Operating current
L/N
Uc
UT
Ic
DS41-400
230/400V
440 Vac
770 Vac
< 1 mA
DS41-320
230/400 V
320 Vac
440 Vac
< 1 mA
DS41-280
230/400 V
280 Vac
440 Vac
< 1 mA
DS41-230
230/400V
255 Vac
440 Vac
< 1 mA
DS41-120
120/208V
150 Vac
230 Vac
< 1 mA
If
In
none
20 kA
none
20 kA
none
20 kA
none
20 kA
none
20 kA
Imax
40 kA
40 kA
40 kA
40 kA
40 kA
Up
1.8 kV
1.5 kV
1.3 kV
25000 A
1.5 kV
1.3 kV
1.2 kV
25000 A
1.3 kV
1.2 kV
1 kV
25000 A
1.25 kV
1.1 kV
0.9 kV
25000 A
0.9 kV
0.7 kV
0.6 kV
Leakage current at Uc
Follow current
Nominal discharge current
15 x 8/20 s impulse
90
Isccr
25000 A
67
18
Thermal disconnector
Fuses
Installation ground fault breaker
internal
Fuses type gG - 50 A max. (see Note 1)
Type S or delayed
12
11
L/N
14
Mechanical characteristics
MI
Ft
t
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
see diagram
by screw terminals :2.5-25 mm / by bus
1 mechanical indicator
Option DS40S - output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
EN 61643-11
IEC 61643-11
NF EN 61643-11
UL1449 ed.3
V: High-energy varistor
Ft: Thermal fuse
C: Remote signaling contact
t: Thermal disconnection system
Mi : Disconnection indicator
Europe
International
France
USA
Part Number
DS41-400
DS41-230
DS41-280
DS41-230
DS41-120
3314011
331901
3311011
3317011
3316011
Note 1: Rating in compliance with NF C15-100 art.534.1.5.3. In order to increase service continuity, higher rating can be used (up to 125 A). For
further information, please consult product instructions..
45
DS4x S-xxx/G
= CT1 conguration (common mode)
G = CT2 (common and differential mode)
Operating voltage
S = Remote signal option
Number of protected poles (2, 3 or 4)
DS44-230/G
Dimensions - Diagram
1
67
L/NL
/N
LN
L1
L2
2
L/N
L/N
L1
L2
L3
L3
MI
Ft
t
MI
Ft
MI
Ft
MI
Ft
90
MI
Ft
t
MI
Ft
t
GSG
C
14
11
12
14
11
12
14
11
12
9
44
36
36
54
60.8
L1
L2
L3
L1
L3
L2
MI
Ft
L1
L2
L3
L1
L2
L3
Ft
MI
Ft
t
MI
MI
Ft
MI
Ft
t
Ft
t
MI
Ft
MI
GSG
14
11
12
14
11
12
72
72
Part number
Network
AC system
DS44-230/G
461512
230/400 V 3-phase+N
TT-TNS
DS44-120/G
461612
120/208 V 3-phase+N
TT-TNS
DS44-400
461402
230/400 V 3-phase+N
IT-TNS
DS44-230
461502
230/400 V 3-phase+N
TNS
DS44-120
461602
120/208 V 3-phase+N
TNS
DS43-400
461403
400 V 3-phase
IT-TNC
DS43-230
461503
400 V 3-phase
TNC
DS43-120
461603
208 V 3-phase
TNC
DS42-230/G
461511
TT-TN
DS42-120/G
461611
TT-TN
DS42-400
461401
IT
DS42-230
461501
TN
DS42-120
461601
TN
differential
Reference
common
Protection
mode
Imax
total
Up
L/PE
Up
L/N
40 kA
1.5 kV
1.25 kV
40 kA
1.5 kV
0.9 kV
160 kA
1.8 kV
160 kA
1.25 kV
160 kA
0.9 kV
120 kA
1.8 kV
120 kA
1.25 kV
120 kA
0.9 kV
40 kA
1.5 kV
1.25 kV
40 kA
1.5 kV
0.9 kV
80 kA
1.8 kV
80 kA
1.25 kV
80 kA
0.9 kV
Diagram
*) DSx-280x or DS4x-320x (e.g: DS44-320/G) in case of possible temporary voltages (bad quality AC voltage or supply by AC generator set).
46
DS10 series
In : 5 kA
Imax : 10 kA
DS11-120
Characteristics
(in mm)
DS11S (1 pole)
9
L/N
DS11-400
DS11-230
DS11-120
Uc
UT
Ic
230/400V
TT-IT
440 Vac
770 Vac
< 1 mA
230/400V
TN
255 Vac
440 Vac
< 1 mA
120/208V
TN
150 Vac
230 Vac
< 1 mA
If
In
none
5 kA
none
5 kA
none
5 kA
Imax
10 kA
10 kA
10 kA
Up
Uoc
1.3 kV
10 kV
0.9 kV
10 kV
0.6 kV
10 kV
Isccr
25000 A
25000 A
25000 A
Leakage current at Uc
Follow current
Nominal discharge current
90
15 x 8/20 s impulses
67
18
internal
Fuses type gG - 20 A max. (see Note 1)
Type S or delayed
12
11
14
Mechanical characteristics
L/N
MI
Ft
t
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
See diagram
by screw terminals : 2.5-25 mm / by bus
1 mechanical indicator by pole
Option DS10S - output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
NF EN 61643-11
IEC 61643-11
EN 61643-11
UL1449 ed.3
V : Varistor
Ft : Thermal fuse
C : Remote signaling contact
t : Thermal disconnection system
MI : Disconnection indicator
47
France
International
Europe
USA
Part number
DS11-400
DS11-230
DS11-120
341401
341501
341601
Note 1: Rating in compliance with NF C15-100 art.534.1.5.3. In order to increase service continuity, higher rating can be used (up to 40 A).
For further information, please consult product instructions.
DS1x S-xxx/G
= CT1 conguration (common mode)
G = CT2 (common and differential mode)
Operating voltage
S = Remote signal option
Number of protected poles (2, 3 or 4)
DS14-230/G
Dimensions - Diagrams
1
67
L/NL
/N
LN
L1
L2
2
L/N
L3
L/N
MI
Ft
t
MI
Ft
L1
MI
Ft
MI
Ft
L2
L3
MI
Ft
t
MI
Ft
t
GSG
90
C
14
11
12
14
11
12
14
11
12
9
44
36
36
54
60.8
L1
L2
MI
Ft
t
L1
L2
L3
L1
L2
L3
Ft
t
L3
MI
Ft
t
MI
Ft
L1
MI
Ft
t
MI
Ft
MI
GSG
C
14
11
12
14
11
12
72
MI
Ft
t
L3
L2
72
Network
AC system
DS14-230/G
471512
230/400 V 3-phase+N
TT-TNS
DS14-120/G
471612
120/208 V 3-phase+N
TT-TNS
DS14-400
471402
230/400 V 3-phase+N
IT-TNS
DS14-230
471502
230/400 V 3-phase+N
TNS
DS14-120
471602
120/208 V 3-phase+N
TNS
DS13-400
341403
400 V 3-phase
IT-TNC
DS13-230
341503
400 V 3-phase
TNC
DS13-120
341603
208 V 3-phase
TNC
DS12-230/G
471511
TT-TN
DS12-120/G
471611
TT-TN
DS12-400
471401
IT- TN
DS12-230
471501
TN
DS12-120
471601
TN
differential
References
common
Protection
mode
Part
number
Imax
total
Up
L/PE
Up
L/N
40 kA
1.5 kV
0.9 kV
40 kA
1.5 kV
0.6 kV
40 kA
1.3 kV
40 kA
0.9 kV
40 kA
0.6 kV
30 kA
1.3 kV
30 kA
0.9 kV
30 kA
0.6 kV
20 kA
1.5 kV
0.9 kV
20 kA
1.5 kV
0.6 kV
20 kA
1.3 kV
20 kA
0.9 kV
20 kA
0.6 kV
Diagram
48
DS240 series
In : 20 kA
Imax : 40 kA
Common/Differential mode
Pluggable module
UL1449 ed.3
DS240 S-xxx/G
= CT1 conguration (common mode)
G = CT2 (common and differential mode)
Operating voltage
DS240-40
DS240-400
Characteristics
(in mm)
DS240-400
DS240-230/G DS240-120/G
Single-phase network
Neutral conguration
Max. operating voltage
Temporary overvoltage withstand
Operating current
Uc
UT
Ic
230 V
IT-TN
440 Vac
770 Vac
< 1 mA
230 V
TT-TN
255 Vac
440 Vac
none
120 V
TT-TN
150 Vac
230 Vac
none
In
CM (2)
20 kA
CM/DM (2)
20 kA
CM/DM (2)
20 kA
Imax
40 kA
40 kA
40 kA
Up
1.8 kV
1.3 kV
10000 A
1.5/1.25 kV (2)
1.5/0.9 kV
10000 A
1.5/0.9 kV (2)
1.5/0.6 kV
Leakage current at Uc
Protection mode(s)
Nominal discharge current
90
15 x 8/20 s impulses
10000 A
67
18
Thermal disconnector
Fuses
Installation ground fault breaker
internal
Fuses type gG - 50 A max. (see Note 1)
Type S or delayed
Ft
Ft
MI t
Ft
MI
12
11
14
L(L) N(N)
12
14
L(L) N(N)
11
Mechanical characteristics
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
see diagram
by screw terminals : 1,5-10 mm (L/N) or 2,5-25 mm (PE)
2 (or 1) mechanical indicators
Option DS240S - output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
DS240S-xxx
DS240S-xxx/G
NF EN 61643-11
IEC 61643-11
EN 61643-11
UL1449 ed.3
France
International
Europe
USA
Part number
V : High energy varistor
GDT : High energy Gas tube
Ft : Thermal fuse
C : Remote signaling contact
t : Thermal disconnection system
49
DS240-400
DS240-230/G
DS240-120/G
311401
311721
3116+21
Note 1: Rating in compliance with NF C15-100 art. 534.1.5.3. An order to increase service continuity, higher rating can be used (up to 125
A). For further information, please consult product instructions.
Note 2 : CM = Common mode (L/PE ou N/PE)/ DM = Differential mode (L/N)
DS440 series
In : 20 kA
Imax : 40 kA
Common/Differential mode
Pluggable module
DS440-400
Characteristics
(in mm)
67
L1
L2
L3
DS440-400
DS440-230/G DS440-120/G
3-phase network
Neutral conguration
Max. operating voltage
Temporary overvoltage withstand
Operating current
Uc
UT
Ic
230 V
IT-TN
440 Vac
770 Vac
< 1 mA
230 V
TT-TN
255 Vac
440 Vac
none
120 V
TT-TN
150 Vac
230 Vac
none
In
CM (2)
20 kA
CM/DM (2)
20 kA
CM/DM (2)
20 kA
Imax
40 kA
40 kA
40 kA
Up
1.8 kV
1.3 kV
10000 A
1.5/1.25 kV
1.5/0.9 kV
10000 A
1.5/0.9 kV
1.5/0.6 kV
Leakage current at Uc
Protection mode(s)
Nominal discharge current
90
15 x 8/20 s impulses
10000 A
44
36
60.8
Thermal disconnector
Fuses
Installation ground fault breaker
internal
Fuses type gG - 50 A max. (see Note 1)
Type S or delayed
Mechanical characteristics
L1
L2
L3
DS440S-xxx
Ft
Ft
MI t
Ft
Ft
MI t
14
L3
11
12
L2
DS440S-xxx/G
MI
Ft
Ft
see diagram
by screw terminals : 1,5-10 mm (L/N) or 2,5-25 mm (PE)
4 (or 3) mechanical indicators
Option DS440S - output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
L1
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
Ft
MI t
NF EN 61643-11
IEC 61643-11
EN 61643-11
UL1449 ed.3
Part number
DS440-400
DS440-230/G
DS440-120/G
France
International
Europe
USA
14
11
12
Note 1: Rating in compliance with NF C15-100 art. 534.1.5.3. An order to increase service continuity, higher rating can be used (up to 125
A). For further information, please consult product instructions.
Note 2 : MC = Common mode (L/PE ou N/PE)/ MD = Differential mode (L/N)
50
DS215 series
In : 5 kA
Imax : 15 kA
Common/Differential mode
Pluggable module
UL1449 ed.3
DS215 S-xxx/G
= CT1 conguration (common mode)
G = CT2 (common and differential mode)
Operating voltage
DS215-400
Characteristics
(in mm)
DS215-400
DS215-230/G DS215-120/G
Single-phase network
Neutral conguration
Max. operating voltage
Temporary overvoltage withstand
Operating current
Uc
UT
Ic
230 V
IT-TN
440 Vac
770 Vac
< 1 mA
230 V
TT-TN
255 Vac
440 Vac
none
120 V
TT-TN
150 Vac
230 Vac
none
In
CM (2)
5 kA
CM/DM (2)
5 kA
CM/DM (2)
5 kA
Imax
15 kA
15 kA
15 kA
Up
1.3 kV
1.3 kV
10000 A
1.5/0.9 kV
1.5/0.9 kV
10000 A
1.5/0.6 kV
1.5/0.6 kV
Leakage current at Uc
Protection mode(s)
Nominal discharge current
90
15 x 8/20 s impulses
Isccr
10000 A
67
18
Thermal disconnector
Fuses
Installation ground fault breaker
internal
Fuses type gG - 20 A max. (see Note 1)
Type S or delayed
Ft
Ft
MI t
Ft
MI
12
11
14
L(L) N(N)
12
14
11
Mechanical characteristics
L(L) N(N)
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
see diagram
by screw terminals : 1,5-10 mm (L/N) or 2,5-25 mm (PE)
2 (or 1) mechanical indicators
Option DS215S - output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
DS215S-xxx
DS215S-xxx/G
NF EN 61643-11
IEC 61643-11
EN 61643-11
UL1449 ed.3
France
International
Europe
USA
451401
451721
451621
DS215S-400
DS215S-230/G
DS215S-120/G
Part number
V : High energy varistor
Ft : Thermal fuse
C : Remote signaling contact
t : Thermal disconnection system
GDT :Gas discharge tube N/PE
MI : Disconnection indicator
51
DS215-400
DS215-230/G
DS215-120/G
451411
451731
451631
Note 1: Rating in compliance with nominal discharge current. In order to increase service continuity, higher rating can be used (up to 125
A). For further information, please consult product instructions.
Note 2 : MC = Common mode (L/PE or N/PE)/ MD = Differential mode (L/N)
DS415 series
In : 5 kA
Imax : 15 kA
Common/Differential mode
Pluggable module
DS415-400
Characteristics
(in mm)
67
L1
L2
L3
DS415-400
DS415-230/G DS415-120/G
3-phase network
Neutral conguration
Max. operating voltage
Temporary overvoltage withstand
Operating current
Uc
UT
Ic
230/400 V
IT-TN
440 Vac
770 Vac
< 1 mA
230 V
TT-TN
255 Vac
440 Vac
none
120 V
TT-TN
150 Vac
230 Vac
none
In
CM (2)
5 kA
CM/DM (2)
5 kA
CM/DM (2)
5 kA
Imax 15 kA
15 kA
15 kA
Up
1.5/0.9 kV
1.5/0.9 kV
10000 A
1.5/0.6 kV
1.5/0.6 kV
Leakage current at Uc
Protection mode(s)
Nominal discharge current
90
15 x 8/20 s impulses
1.3 kV
1.3 kV
Isccr 10000 A
10000 A
44
36
60.8
Thermal disconnector
Fuses
Installation ground fault breaker
internal
Fuses type gG - 20 A max. (see Note 1)
Type S or delayed
Mechanical characteristics
L1
L2
L3
DS415S-xxx
Ft
Ft
MI t
Ft
Ft
MI t
14
L3
11
12
L2
DS415S-xxx/G
MI
Ft
Ft
see diagram
by screw terminals : 1,5-10 mm (L/N) or 2,5-25 mm (PE)
4 (or 3) mechanical indicators
Option DS415S - output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
L1
Dimensions
Connection
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
NF EN 61643-11
IEC 61643-11
EN 61643-11
UL1449 ed.3
France
International
Europe
USA
451402
451722
451622
DS415S-400
DS415S-230/G
DS415S-120/G
Part number
Ft
MI t
DS415-400
DS415-230/G
DS415-120/G
C
451412
451732
451632
14
11
12
Note 1: Rating in compliance with nominal discharge current. In order to increase service continuity, higher rating can be used (up to 40
A). For further information, please consult product instructions.
Note 2 : MC = Common mode (L/PE or N/PE)/ MD = Differential mode (L/N)
52
DS98 series
In: 5 kA
Imax: 10 kA
Common/Differential mode
DS98-400
Characteristics
(in mm)
58
DS98-400
DS98-120
230 V
IT-TN
275 Vac
440 Vac
120 V
TT-TN
150 Vac
230 Vac
Uc
UT
IL
16 A
16 A
Ic
none
none
If
In
without
5 kA
without
5 kA
Imax
10 kA
10 kA
Up
1.5 kV/ 1 kV
Uoc
10 kV
10 kV
Isccr
10000 A
10000 A
Leakage current
Leakage current at Uc
90
Follow current
Nominal discharge current
15 x 8/20 s current impulse
L N
Thermal disconnetor
Fuses
RDC breaker (if any)
internal
Fuse type gG - 20 A max. (see Note 1)
S Type or delayed
Caractristiques mcaniques
Ft
t
Dimensions
Connection to network
Disconnection indicator
Mounting
Operating temperature
Protection rating
Housing material
Ft
t
LED
GDT
see diagram
by screw terminal : 2,5 mm max
Red light on
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standard compliance
LN
V : MOV
GDT : Gas tube
Ft : Thermal fuse
t : Thermal disconnection mechanism
LED : Disconnector indicator
NF EN 61643-11
IEC 61643-11
EN 61643-11
UL1449 ed.3
France
International
Europe
USA
Part number
DS98-400
DS98-120
3509011
3509012
Note 1: Rating in compliance with nominal discharge current. In order to increase service continuity, higher rating can be used (up to
40 A). For further information, please consult product instructions.
Note 2 : MC = Common mode (L/PE or N/PE)/ MD = Differential mode (L/N)
53
DS40HF series
RFI Filtering
In: 20 kA
Imax: 40 kA
Pluggable module
DS41HF-12
DS41HF-120
Characteristics
(in mm)
DS41HF-230
DS41HF-120
Typical use
Nominal voltage
Max. operating voltage
Operating current
Un
Uc
Ic
230/400 V
230 V
255 Vac
< 1 mA
120/208 V
120 V
150 Vac
< 1 mA
In
20 kA
20 kA
Imax
40 kA
40 kA
Up
1,25 kV
0,1-30 Mhz
0,9 kV
0,1-30 Mhz
Isccr
25000 A
25000 A
Leakage voltage at Un
1 x 8/20 s impulse
67
12
11
L/N
14
18
internal
Type gG fuse - 50 A
Mechanical characteristics
Dimensions
Connection
Disconnection indicator
Mounting
Operating temperature
Housing material
see diagram
by screw terminals : 2.5 - 25 mm
Mechanical indicator
Symmetrical rail (EN50022/DIN46277-3)
-40/+85 C
Polycarbonate UL94-V0
Standards compliance
MI
Ft
RFI
NF EN 61643-11
CEI 61643-11
EN 61643-11
UL1449 3ed.
France
International
Europe
USA
Codes articles
DS41HFS-120
DS41HFS-230
461690
461590
Note 1: Rating in compliance with nominal discharge current. In order to increase service continuity, higher rating can be used (up
to 125 A). For further information, please consult product instructions.
V : MOV
GDT : Gas tube
Ft : Thermal fuse
t : Thermal disconnection mechanism
54
DS-HF series
DS-HF
DSDS
D
S-H
HFF
In : 3kA
Imax : 10 kA
Operating/disconnection indicators
DS-HF
Characteristics
(in mm)
70
59
DS-HF
DS-HF-120
Single-phase network
AC system
Max. operating voltage
Temporary overvoltage withstand
Operating current
Uc
UT
Ic
230 V
IT-TN
255 Vac
440 Vac
< 1 mA
120 V
TT-TN
150 Vac
230 Vac
< 1 mA
IL
In
16 A
3 kA
16 A
3 kA
Imax
10 kA
10 kA
Up
Uoc
1 kV/ 0.8 kV
6 kV
Isccr
0.1 - 30 MHz
10000 A
0.1 - 30 MHz
10000 A
leakage current at Uc
90
RFI ltering
Admissible short-circuit current
internal
Fuses type gG - 20 A max. (see Note 1)
Type S or delayed
Mechanical characteristics
LED
LED
RFI
Lin
Lout
Nout
Nin
Ft
t
Ft
Ft
t
GDT
Dimensions
Connection
Voltage/operating indicator
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
see diagram
by screw terminals : 0,75 - 4 mm
Green led(s) on
Green led off
none
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
V: Varistor
GDT: Gas discharge tube
Ft: Thermal fuse
t: Thermal disconnection system
NF EN 61643-11
IEC 61643-11
EN 61643-11
UL1449 ed.3
France
International
Europe
USA
Part number
DS-HF
DS-HF-120
77945
77948
Note 1: Rating in compliance with NF C15-100 art. 534.1.5.3. In order to increase service continuity, higher rating can be used (up to
40 A). For further information, please consult product instructions.
Note 2 : MC : common mode (L/PE or N/PE) - MD : differential mode (L/N)
55
DS2x0-xxDC series
Compact design
Imax: 20 to 40 kA
Pluggable module
DS230-48DC
DC operating voltage
Remote signal option
Maximal discharge current
12
+ (+)
11
14
(in mm)
C
+
Ft
Ft
MI t
90
67
18
Characteristics
CITEL part number
Nominale DC voltage
Un
Uc
Uc
In
Imax
Up
DS220-12DC
12 Vdc
24 Vdc
20 Vac
10 kA
20 kA
250 V
195 V
DS220-24DC
24 Vdc
38 Vdc
30 Vac
10 kA
20 kA
250 V
195 V
DS230-48DC
48 Vdc
65 Vdc
50 Vac
15 kA
30 kA
300 V
230 V
DS240-75DC
75 Vdc
100 Vdc
75 Vac
20 kA
40 kA
390 V
280 V
DS240-95DC
95 Vdc
125 Vdc
95 Vac
20 kA
40 kA
450 V
310 V
DS240-110DC
110 Vdc
150 Vdc
115 Vac
20 kA
40 kA
500 V
370 V
DS240-130DC
130 Vdc
180 Vdc
150 Vac
20 kA
40 kA
620 V
510 V
DS240-220DC
220 Vdc
275 Vdc
210 Vac
20 kA
40 kA
900 V
690 V
DS240-280DC
280 Vdc
350 Vdc
275 Vac
20 kA
40 kA
1200 V
920 V
DS240-350DC
350 Vdc
460 Vdc
350 Vac
20 kA
40 kA
1400 V
1000 V
internal
20A gG
internal
20A gG
internal
20A gG
internal
50A gG
internal
50A gG
internal
50A gG
internal
50A gG
internal
50A gG
internal
50A gG
internal
50A gG
310701
310801
310201
310501
310901
Mechanical characteristics
Dimensions
Wiring to network
Disconnection indicator
Replacement module
Remote signalling
Mounting
Operating temperature
Protection class
Housing material
see diagram
by screw terminals 1,5-10mm (active wires) and 2,5-25mm (ground)
2 mechanical indicators
pluggable module DSM2x0-xxDC
option (DS2x0S-xxDC) - output on changeover contact
symmetrical rail
-40/+85C
IP 20
thermoplastic UL94-V0
Standards compliance
International
Europe
USA - Canada
Part number
390101
390501
390401
310601
310301
56
DS210-xxDC series
From 12 to 130V
Disconnection indicator
Pluggable module
DS210-xxxDC
DS210-24DC
Nominal DC voltage
Imax
+(+) -(-)
+
LED
90
Ft
t
Ft
t
V: Varistor
Ft: Thermal fuse
t: Thermal disconnection system
LED : Disconnection indicator
67
18
Characteristics
CITEL part number
Nominal DC voltage
Maximal AC voltage
Maximal DC voltage
Nominal discharge current
DS210-12DC DS210-24DC
Un-dc
Uc
Uc-dc
In
12 Vdc
10 Vac
15 Vdc
1 kA
24 Vdc
15 Vac
30 Vdc
1 kA
48 Vdc
40 Vac
56 Vdc
1 kA
75 Vdc
60 Vac
85 Vdc
2 kA
95 Vdc
75 Vac
100 Vdc
2 kA
110 Vdc
95 Vac
125 Vdc
2 kA
130 Vdc
115 Vac
150 Vdc
2 kA
Imax
2 kA
2 kA
2 kA
6 kA
6 kA
6 kA
6 kA
Up
85 V
105 V
180 V
250 V
300 V
350 V
400 V
440901
440602
15 x 8/20 s impulses
internal
Fuses type gG - 10 A
Mechanical characteristics
Dimensions
Connection
Disconnection indicator
Mounting
Operating temperature
Protection class
Housing material
see diagram
by screw terminals : 1.5-10 mm (active wires) - 2,5-25 mm (Ground)
Green led off
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Part number
440201
57
440301
440401
440601
441001
Coordination inductors
DSH series
DSH 35
Characteristics
(in mm)
DSH2x16
DSH2x35
DSH63
DSH35
59
36
DSH100
DSH63
DSH35
Type
inductor
inductor
inductor
Connexion mode
1 DSH in
series on
each active
wire
500 Vac
100 A
15 H
72
90
Uc
IL
DSH2x35
DSH2x16
double
inductor
1 DSH in
1 DSH in
1 DSH in
series on
series on
series on
each active each active 2 active
wire
wire
wires
500 Vac
500 Vac
500 Vac
63 A
35 A
2 x 35 A
15 H
15 H
2 x 15 H
double
inductor
1 DSH in
series on
2 active
wires
500 Vac
2 x 16 A
2 x 15 H
Mechanical characteristics
Dimensions
Connection
DSH100
59
Mounting
Operating temperature
Protection class
Housing material
106
see diagram
screw terminals : 6-35 mm (DSH2x16, DSH2x35, DSH35, DSH63)
screw terminals : 4-50 mm (DSH100)
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0 and UL94-5VA (DSH35-DSH2x16)
Part Number
DSH100
DSH63
DSH35
DSH2x35
DSH2x16
90
465100
360807
360806
360808
2690
DSH2x16 - DSH2x35
L
L
L : inductor
58
59
PHOTOVOLTAIC
Surge Protectors
60
Protection of PV installation
The photovoltaic grid-connected low voltage power lines may be
subject to overvoltages on different networks:
AC network: surge protectors are necessary, and in most
cases, mandatory on the AC output of the PV inverter which is
connected back to the AC power grid.
DC network: surge protectors are required or mandatory on the
input of the PV inverter or the input of the PV modules.
61
Series
Description
Characteristics
Page
DS60VGPV
High energy
VG Technology
65
DS50VGPV
Type 2 surge
protector for PV
Pluggable
VG Technology
66
DS50PV
Type 2 surge
protector for PV
Pluggable
67
CPV
68
To complete its offer and meet the needs of users, CITEL offers a
range of surge protector enclosures for PV applications. The CPV
range are intended for installation at the AC output or DC input of the
PV inverters and can includeType 1 or Type 2 surge protection, circuit
breakers for array strings and a single disconnection device. Many
congurations are available.
AC surge protector
DC surge protector
Differential circuit breaker
Disconnection SPD
DC isolator
Connector PV
CPV240
CPV50
L
AC
DDR
DC
t
Pac
V
Pdc
62
62
Pluggable module
Disconnection for simplied
maintenance.
Standardized marking
Connectors
Signicant physical separation screw
terminal blocks: ensuring insulation
between polarities even for high DC
voltages
Status signaling
In case of safety disconnection,
the indicator switches to red:
module to replace.
Versions
several diagrams available
DS50PV/51 and DS50VGPV
Remote signalling
Option to remotely monitor the status of the surge protector. Simplied
cabling thanks to a single terminal
for monitoring all poles.
DS60VGPV/51 series
Earth
Double connector for optimized
connection ground network.
Connectors
Signicant physical separation screw
terminal blocks: guarantee insulation
between polarities even for high DC
voltages
VG Technology
Efciency and reliability maximum
Status signaling
Remote signalling
Standard feature to remotely monitor
the status of the surge protector.
Simplied cabling thanks to a single
terminal for monitoring all poles.
63
>10m
DU
T25
0VG- 300
ZP
ou
DS
DS
50V
GPVS-1
00
60VGPV-100
Business/Building
Photovoltaic installation
Commercial or industrial sites can integrate
very large photovoltaic systems into their power
generation strategy. These applications are
vulnerable to lightning and transient surges
which can cause signicant downtime and
losses. The implementation of SPDs at key
locations throughout the facility is necessary to
ensure the reliable operation of the plant.
Pane PV
l C
D S 13 4 V G
DS2
53VG-30
DLA
DS
DS
DS
60VGPV-100
60VGPV-100
50V
GPVS-1
00
D L A -0 6 D 3
DS2
53VG-30
64
64
DS60VGPV/51 series
VG-Technology
Remote Signaling
EN 50539-11 compliance
DS60VGPV-xxxG/51
DS60VGPV-1500G/51
Maximum PV voltage
Characteristics
(in mm)
CITEL part number
Network voltage
90
70
Protection mode *
+/-
-/+
1000 Vdc
1250 Vdc
CM/DM
CM/DM
CM/DM
Ucpv
720 Vdc
1200 Vdc
1500 Vdc
Iscwpv
Icpv
>1000 A
none
>1000 A
none
>1000 A
none
Ipe
none
non
none
If
In
none
20 kA
none
20 kA
none
20 kA
Iimp
12.5 kA
12.5 kA
12.5 kA
Imax
40 kA
40 kA
40 kA
Up
2.2/2.8 kV
3.4/4.9 kV
3.4/6 kV
Leakage current
90
Follow current
Nominal discharge current
15 x 8/20 s impulses
8/20s withstand
Disconnector
Thermal Disconnector
+/-
-/+
MI
Ft
Ft
t
GSG
GSG
GSG
internal
Mechanical characteristics
Dimensions
see diagram
Connection
Disconnection indicator
1 mechanical indicator
Mounting
symmetrical rail 35 mm
-40/+85 C
Protection class
IP20
Housing material
Thermoplastic UL94-V0
14
11
12
Operating temperature
Standards compliance
UTE C61-740-51
EN 50539-11
UL1449 ed.3
France
Europe
USA
Part Number
DS60VGPV-600G/51
3963
DS60VGPV-1000G/51
3958
DS60VGPV-1500G/51
3956
65
DS50VGPV-G/51 series
VG-Technology
EN 50539-11 compliance
DS50VGPVS-xxxG/51
DS50VGPV-1500G/51
Maximum PV voltage
S remote signalling status option
Characteristics
(in mm)
CITEL part number
80
-/+
+/-
Network voltage
Protection mode *
Max. operating voltage
Current withstand short-circuit
Operating current
Ucpv
Iscwpv
Icpv
DS50VGPV-600G/51
600 Vdc
CM/DM
720 Vdc
>1000 A
none
DS50VGPV-1000G/51
1000 Vdc
CM/DM
1200 Vdc
>1000 A
none
DS50VGPV-1500G/51
1250 Vdc
CM/DM
1500 Vdc
>1000 A
none
Ipe
none
none
none
If
In
none
15 kA
none
15 kA
none
15 kA
Imax
40 kA
40 kA
40 kA
Up
2.2/3.4 kV
3.5/6 kV
3.4/6.8 kV
Uocstc
Leakage current
to the voltage Ucpv
90
Follow current
Nominal discharge current
15 x 8/20 s impulses
Disconnector
9
44
54
74
+/-
-/+
MI
Ft
Ft
MI
t
GSG
GSG
GSG
C
14
11
12
Thermal Disconnector
internal
Mechanical characteristics
Dimensions
Connection
Disconnection indicator
Remote signaling
Mounting
Operating temperature
Protection class
Housing material
see diagram
Screw terminal for 2.5-25 mm wire
1 mechanical indicator by pole
Option DS50VGPVS-xxxG/51 - Output on changeover contact
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
UTE C61-740-51
EN50539-11
UL1449 ed.3
France
Europe
USA
66
DS50PV/51 series
In : 15 kA
Imax : 40 kA
Pluggable module
EN 50539-11 compliance
DS50PVS-xxxG/51
Maximum PV voltage
S = remote signalling status option
DS50PV-800G/51
Characteristics
(in mm)
CITEL part number
DS50PV-500/51
DS50PV-600/51
67
+/-
DS50PV-800G/51
DS50PV-1000G/51
-/+
+/-
-/+
Maximum PV voltage
Protection mode *
Max. operating voltage
Short circuit current withstand
Operating current
DS50PV-500/51
Uocstc 500 Vdc
CM
Ucpv
600 Vdc
Iscwpv >1000 A
Icpv
< 0.1 mA
DS50PV-600/51
600 Vdc
CM
720 Vdc
>1000 A
< 0.1 mA
DS50PV-800G/51
800 Vdc
CM/DM
960 Vdc
>1000 A
< 0.1 mA
DS50PV-1000G/51
1000 Vdc
CM/DM
1200 Vdc
>1000 A
< 0.1 mA
Ipe
< 0.1 mA
< 0.1 mA
none
none
In
15 kA
15 kA
15 kA
15 kA
Imax
40 kA
40 kA
40 kA
40 kA
2.2 kV
2.8 kV
2 / 3.6 kV
2.2 / 4.4 kV
Leakage current
to the voltage Ucpv
90
Disconnector
9
44
DS50PV-500/51
DS50PV-600/51
DS50PV-800G/51
DS50PV-1000G/51
+/-
-/+
-/+
MI
MI
Ft
Ft
MI
t
t
GSG
14
11
12
14
11
12
67
internal
Dimensions
Connection
End of life mode
Disconnection indicator
Remote signaling of disconnection
Mounting
Operating temperature
Protection class
Housing material
Ft
Thermal disconnector
Mechanical characteristics
+/Ft
54
36
60.8
MI
see diagram
by screw terminal : 2.5-25 mm
disconnection of the SPD from PV line
1 mechanical indicator by pole
Option DS50PVS-xxx/51 - output on changeover contac
symmetrical rail 35 mm
-40/+85 C
IP20
Thermoplastic UL94-V0
Standards compliance
EN50539- 11
UTE C61-740-51
Europe
France
Part number
DS50PV-500/51
DS50PV-600/51
DS50PV-800G/51
DS50PV-1000G/51
480121
480421
480281
480381
CPV240-230-xxx-DDR
Network voltage
Maximum line current
Network connection (intput/output)
Un
Security
Thermal disconnector
Indicator of SPD disconnection
SPD protection
Overcurrent protection
Protection against indirect contacts
internal to SPD
indicator on SPD
circuit breaker in surge protector branch
by line circuit breaker (16 or 32 A rating)
by differential circuit breaker 30mA
DS240-230/G
Uc
In
Imax
Up
255 Vac
20 kA
40 kA
1,5/1,25 kV
Enclosure characteristics
AC network connection
Protection level
Dimensions (H x L x P) mm
Enclosure material
Access equipment
Cable routing
IP 55
198 x 255 x 108
Polycarbonate UL 94VO
Transparente door
through cable glands
Number of strings
Max. PV voltage
Uocstc
Max. PV current
Imppstc
Network connection (input/output)
DC switch
Fuses protection by strings
3
500 Vdc
25 A
terminal 6,5/10 mm
yes
option
DS50PV-500/51
600 Vdc
15 kA
40 kA
2,2 kV
Ucpv
In
Imax
Up
3
600 Vdc
25 A
terminal 6,5/10 mm
yes
option
DS50PV-600/51
720 Vdc
15 kA
40 kA
2,8 kV
3
800 Vdc
25 A
terminal 6,5/10 mm
yes
option
DS50PV-800G/51
960 Vdc
15 kA
40 kA
2/3,6 kV
Enclosure characteristics
Max. current : 25 A
PV network switching
Protection level
Dimensions (HxLxP)
Enclosure material
Type of handle
IP65
305 x 225 x 125 mm
ABS PC
external lockable
CPV240-50-230-xx-DDR
Un/Uocstc
2 strings - DC network
600 Vdc
25A
6mm max in terminal resort
type MC connector
Security
Thermal disconnector
Indicator of SPD disconnection
SPD protection
Overcurrent protection
Protection against indirect contacts
Uc/Ucpv
In
Imax
Up
Enclosure characteristics
PV network switching
Dimensions (H x L x P)
Enclosure material
Protection level
Access equipement
Shift cable
68
DS2x0-xxDC series
Compact
Imax: 20 to 40 kA
Pluggable module
Characteristics
CITEL part number
DS220-12DC DS220-24DC DS230-48DC DS240-75DC DS240-95DC DS240-110DC DS240-130DC DS240-220DC DS240-280DC DS240-350DC
DC nominal voltage
Un
12 Vdc
24 Vdc
48Vdc
75 Vdc
95 Vdc
110 Vdc
130 Vdc
220 Vdc
280 Vdc
350 Vdc
Uc
24 Vdc
38 Vdc
65 Vdc
100 Vdc
125 Vdc
150 Vdc
180 Vdc
275 Vdc
350 Vdc
460 Vdc
350 Vac
Uc
20 Vac
30 Vac
50 Vac
75 Vac
95 Vac
115 Vac
150 Vac
210 Vac
275 Vac
In
10kA
10 kA
15 kA
20 kA
20kA
20 kA
20 kA
20 kA
20 kA
20 kA
Imax
20 kA
20 kA
30 kA
40 kA
40 kA
40 kA
40 kA
40 kA
40 kA
40 kA
Up
1400 V
250 V
250 V
300 V
390 V
450 V
500 V
620 V
900 V
1200 V
195 V
195 V
230 V
280 V
310 V
370 V
510 V
690 V
920 V
1000 V
Dimension (width)
18 mm
18 mm
18 mm
18 mm
18 mm
18 mm
18 mm
18 mm
18 mm
18 mm
Protection of Isolated
(off-grid) PV systems
The exposure and location of remote
sites powered by isolated PV systems
not connected to the AC network are
at a very high risk of failure due to
transient surges.
Unlike the sites connected to the
distribution network, PV equipment
failure at a remote site will result
in a total operating loss: thus, the
implementation of appropriate surge
protection is strongly recommended.
The selection and installation of surge
protectors for off-grid sites in the
future will be defined in the UTE C15712-2 guide.
Group-Wind-BT Network
t
AC surge protector
Equipments
external remote
Pumps-Lighting...
PV modules
AC
DC
DC surge protector
DC
DC
AC internal
charges
Solar charge
controler
t
Battery
DC internal
charges
*) surge arrester at the terminals of the necessary equipment away from more than 10 m of the facility
69
AC POWER
Surge Protectors
70
MLP series
Surge protector compact, designed for the protection of equipment
particularly vulnerable to transient overvoltages This complete range
offers numerous congurations:
71
M series
These standalone enclosures are AC surge protectors that have been
specically designed for standards, networks and installations in
North America.
They are available in all single, dual or three phase congurations and
are equipped with various diagnostic options. Housed in a NEMA 4
metal enclosures, these surge protectors are available in various per
phase surge capacities (Imax = 80, 100, 160 and 200 kA).
The protection circuit is based on a combination of high energy varistors and lter capacitors to provide a very high discharge current capability with EMI / RFI ltering. Manufactured in accordance with the
UL1449 standard, the safe operation is ensured by real-time diagnostics including fault indicators (LEDs), an audible alarm, and remote
signal contacts.
Series
Description
Characteristics
Page
MSB
Hard-wired
surge protector
Type 2 or 3
compact
72
MLP
Hard-wired
surge protector
Type 2 or 3
Signaling and
Data (option)
73
CBC
Surge protector
combiner boxes
Type 1 and Type 2
Many
congurations
75
Srie M
Surge protector
combiner boxes
US market
Compliance
UL1449
80 to 200 kA
76
M15
M50
Hard-wired surge
protector
US market
Single-phase or
3-phase
77
MSB6-400
Status indicators
24 V AC or DC version available
MSB10-400
MSB10-UL
MSB10C
50
40
diam 4
MSB10V
68
50
25.2
MSB10
50
40
diam 4
MSB6
35
40
BUZZER
25
60
42
60
60
42
60
150
LED
LED
LED
380
L
Equipt
N L
11
L
34
L
Equipt
MSB10-UL
22
24
N
L N
Line
MSB10C-MSB10V
MSB6-400
MSB10
MSB6-24
Buzzer
Ft
V1
V3
PE
MSB10-UL
150
Line
L N
MSB10
V2
Ft
MSB10C
MSB6
MSB10-400
MSB10-120
MSB10V-400
MSB10V-120
MSB10C-400
MSB6-400
MSB6-24
230-277 Vac
300 Vac
1.2 kV
347-480 Vac
550 Vac
1.8 kV
230 Vac
255 Vac
1.5 kV
110-130 Vac
150 Vac
1 kV
230 Vac
255 Vac
16 A
1.5 kV
110-130 Vac
150 Vac
16 A
1.5 kV
230 Vac
255 Vac
16 A
1.5 kV
230 Vac
255 Vac
1.5 kV
24 Vac- 24 Vdc
30 Vac-38 Vdc
0.18 kV
Imax
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
6 kA
2 kA
In
3 kA
3 kA
3 kA
3 kA
3 kA
3 kA
3 kA
3 kA
0.5 kA
Uoc
6 kV
6 kV
6 kV
6 kV
6 kV
6 kV
6 kV
6 kV
1 kV
disconnection
disconnection
disconnection
disconnection
disconnection
AC line cut-off
disconnection
AC line cut-off
disconnection
AC line cut-off
disconnection
disconnection
Disconnection signaling
Wiring
Mounting
buzzer
wires
buzzer
wires
wall or plate
wall or plate
wall or plate
wall or plate
wall or plate
wall or plate
wall or plate
AC outlet
AC outlet
IP66
IP66
IP65
IP65
IP20
IP20
IP20
IP65
IP65
compliance
1 impulse @ 8/20 s
Un
Uc
IL
Up
MSB10V
V : Varistor
Ft : Thermal fuse
LED : Disconnection indicator
T : Thermal system disconnection
GDT : Gas Discharge Tube
Mechanical characteristics
Protection Class
Standard compliance
N EN 61643-11
compliance
compliance
compliance
compliance
compliance
compliance
compliance
compliance
UL 1449 ed.3
listed
listed
Part number
560501
561201
561601
561101
561602
561301
561302
72
MLP1-230L-P/RS
MLP1-230L-W/RS
MLP1 - 230L-W/RS
- : No dataline surge protection
RS : RS485 dataline surge protection
DL : Dali transmission surge protection
W : Wire connection
P : Pluggable screw terminal connection
L : Line disconnection failure mode without remote signal
LS : Line disconnection failure mode with remote signal
S : Parallel disconnection failure mode with remote signal
- : Parallel disconnection failure mode without remote signal
Dimensions - Diagrams
(in mm)
1 : Class I equipment
2 : Class II equipment
MLP1-xxx-W/xx
32
AC
Data
LN
Lin
LED
Ft
led
Nin
t
Lout
Lin
Nout
Nin
Ft
led
to
Lout
Lin
Nout
Nin
Ft
Lout
led
to
Nout
REMOTE
GDT
66 86
MLP1-230L-W
Lin
LN
Data
Ft
led
Nin
39
MLP2-230L-P
Lout
Lin
Nout
Nin
led
Ft
V
MLP2-xxx-P/xx
Lout
Lin
Nout
Nin
to
REMOTE
MLP2-230LS-P
Ft
REMOTE
MLP1-230LS-W
Lin
led
Nin
Ft
V
MLP2-230S-P
Nout
Lout
Lin
Nout
Nin
REMOTE
to
Lout
led
Ft
MLP2-230-P
Nout
REMOTE
70 91
DATA in
G3
MLP1-230S-W/RS
73
GDT
30
49
Lout
led
DATA in
DATA out
MLP2-230S-P/RS
DATA iout
F : Thermal fuse
Led : Status indicator
V : MOV
GDT : Gas Tube
G3 : 3-pole Gas Tube
D : Clamping diode network
Remote : Dry contact for remote signalling
MLP series
Characteristics
CITEL part number
Typical use
Max. load current
Max. operating voltage
Leakage current
Ipe
MLPx-120-x
110-120 VAc
2,5 A
180 Vac
none
MLPx-230-x
230-277 Vac
2,5 A
305 Vac
none
In
5 kA
5 kA
Imax
10 kA
10 kA
10 kV / 10 kA
1 kV
10000 A
10 kV / 10 kA
1,5 kV
10000 A
IL
Uc
MLPx-x/RS
RS485
300 mA
MLPx-x/DL
DALI
300 mA
7 Vdc
none
28 Vdc
none
5 kA (MLP1-xx)
100 A (MLP2-xx)
10 kA (MLP1-xx)
200 A (MLP2-xx)
20 V
5 kA (MLP1-xx)
100 A (MLP2-xx)
10 kA (MLP1-xx)
200 A (MLP1-xx)
40 V
Mechanical characteristics
Termal disconnector
Dimensions
Connection for MLPx-x-W
Connection for MLPx-x-P
Disconnection indicator
Remote signaling of disconnection
IP rating
Housing material
Operating temperature
Mounting
Insulation Class
internal
see diagram
wire 1,5 mm
screw terminal 1,5 mm max.
LED indicator
dry contact
IP65 (MLPx-x-W) - IP20 (MLPx-x-P)
Polycarbonate UL94-V0
-40/+85 C
wall or plate
Class I (MLP1-x) - Class II (MLP2-x)
1,5 mm
screw 1,5 mm
Line short-circuit
Transmission cut-off
C2 category
Standards compliance
IEC 61643-11
EN 61643-11
IEC 61643-21
International
Europe
International
MLP2-230L-P
MLP2-230-P
MLP2-230-P/RS
230-277 Vac
2,5 A
305 Vac
non relevant
5 kA
230/277 Vac
2,5 A
230-277 Vac
2,5 A
Ipe
In
230-277 Vac
2,5 A
305 Vac
none
5 kA
305 Vac
non relevant
5 kA
305 Vac
non relevant
5 kA
Imax
10 kA
10 kA
10 kA
10 kA
Uoc
Up
10 kV / 10 kA
1,5 kV
10000 A
10 kV / 10 kA
1,5 kV
10000 A
10 kV / 10 kA
1,5 kV
10 kV / 10 kA
1,5 kV
10000 A
10000 A
without
-
without
-
without
-
RS485
7 Vac
300 mA
100 A
200 A
20 V
Thermal disconnector
Dimensions
Connection to AC line
Connection for Dataline
Failsafe behavior
internal
see diagram
wire 1,5 mm max
wire 1 mm max
AC network cutoff and LED off
internal
see diagram
screw 1,5 mm max
screw 1 mm max
AC network cutoff and LED off
none
none
IP rating
Housing materiel
Operating temperature
Mounting
Insulation Class
IP65
PA66 UL94V0
-40/+85 C
wall or plate
Class I
IP20
PA66 UL94V0
-40/+85 C
wall or plate
Class II
internal
see diagram
screw 1,5 mm max
screw 1 mm max
AC network cutoff and LED off
dry contact
230VAc - 30 Vdc - 3 A
IP20
PA66 UL94V0
-40/+85 C
wall or plate
Class II
internal
see diagram
screw 1,5 mm max
screw 1 mm max
AC network cutoff and LED off
dry contact
230VAc - 30 Vdc - 3 A
IP20
PA66 UL94V0
-40/+85 C
wall or plate
Class II
AC surge protector
Nominal voltage
Max. Load current
Max. operating voltage
Leakage current
Nominal discharge current
IL
Uc
15 x 8/20 s impulses
Mechanical characteristics
Standards compliance
CEI 61643-11
EN 61643-11
IEC 61643-21
74
CBC series
CBC154-230
Characteristics
(in mm)
CITEL part number
Conguration
Type of protection
Network voltage*
Single phase network (TT, TN)
3-Phase network (TNC, IT)
3-Phase + neutral network (TT, TNS)
Common and differential mode protection
Max. line current
IL
Maximum Power
Operating current
lc
L1 L2 L3 N
SPD
CBC
AC Surge protector panel with fuses
Type 2
Type 1
Type 2
230/400V
230/400V
230/400V
CBC152-230
CBC72-230
CBC42-230
CBC153-400
CBC73-400
CBC43-400
CBC154-230
CBC74-230
CBC44-230
yes
yes
yes
none
none
none
Leakage current at Uc
Follow current
Nominal discharge current
If
ln
none
20 kA
none
30 kA
none
20 kA
lmax
70 kA
40 kA
Iimp
15 kA
25000 A
25000 A
25000 A
15 x 8/20 s impulses
Safety
Thermal disconnectors
Electrical disconnectors
Installation ground fault breaker
Mechanical characteristics
75
CBC152-230
CBC152-120
CBC72-230
CBC72-120
CBC42-230
CBC42-120
230/400V 3-phase
network
120/208V 3-phase
network
CBC153-400
CBC153-120
CBC73-400
CBC73-120
CBC43-400
CBC43-120
230/400V
3-phase + N network
120/208V
3-phase +N network
CBC154-230
CBC154-120
CBC74-230
CBC74-120
CBC44-230
CBC44-120
Dimension
(l x h x p - in mm)
Weight
1,5 kg
1,7 kg
1,4 kg
3,8 kg
2,6 kg
2,4 kg
4,2 kg
3 kg
2,8 kg
Dimensions
Weight
Protection class
Housing material
Operating temperature
Mounting
Wiring access
Connection
Disconnection indication
Remote signaling of disconnection
Standards compliance
IEC 61643-1
NF EN 61643-11
EN 61643-11
International
France
Europe
Dimensions
Characteristics
(in cm)
Series
Max. discharge current
by phase
Imax
Type of Network
120/240 Vac Split Phase 3Ph+PE
120/208 Vac Wye 3Ph/N+PE
220/380 Vac Wye 3Ph/N+PE
277/480 Vac Wye 3Ph/N+PE
240/415 Vac Wye 3Ph/N+PE
120/120/240 Vac Hi-Leg Delta 3Ph/N PE
240 Vac Delta 3Ph+PE
347/600 Vac Wye 3Ph/N+PE
480 Vac Delta 3Ph+PE
Protection modes
Admissible short-circuit current
RFI ltering
Standards compliance
M80
80 kA
M100
100 kA
M160
160 kA
M80-120T
M100-120T
M160-120T
M80-120Y
M100-120Y
M160-120Y
M80-220Y
M100-220Y
M160-220Y
M80-277Y
M100-277Y
M160-277Y
M80-240Y
M100-240Y
M160-240Y
M80-240DCT
M100-240DCT M160-240DCT
M80-240D
M100-240D
M160-2s40D
M160-347Y
M160-480D
L/N - L/PE - N/PE - L/L
200 kA
- 40 dB
UL1449 3rd edtion -IEC 61643-1
Safety
Model
M200
M160
M100
M80
Dimensions (cm)
Thermal disconnector
Electrical disconnector
Failure indicators
Failure indicators in option
L'
h'
Mechanical characteristics
16
18.6
20.3
Housing material
Operating temperature
Mounting
Connection to AC network
Dimensions (H x L x D)
Specific features
Disconnection switch
LISTED
Version
Rseau
Mxxx-120T
Mxxx-120Y
Mxxx-220Y
Mxxx-277Y
Mxxx-240Y
Mxxx-240DCT
Mxxx-240D
Mxxx-347Y
Mxxx-480D
400
400
1000
1000
1000
1000
1500
-
400
400
1000
1000
1000
1000
1000
1500
1500
500
500
1000
1000
1000
1000
1500
-
800
800
1800
1800
1800
1000
1800
3000
3000
no
M200
200 kA
M200-120T
M200-120Y
M200-220Y
M200-277Y
M200-240Y
M200-240DCT
M200-240D
M200-347Y
M200-480D
M15 series
M50-120Y
M15-230SP
In : 5 kA (M15) / 20 kA (M50)
No leakage current
M15
TMOV
(in mm)
TMOV
L1
Ft
TMOV
+
Ft
Ft
M50
M15
GSG
GSG
GSG
PE
PE
88
R
PE
LED
LED D
Green
Green
Ft
L2
LED D
Ft
Green
TMOV
Single Phase AC
20
M50-120Y
Split Phase AC
DC Network
60
88
M50
N
L1
L3
L2
40
V
Ft
Ft
---
---
Characteristics
CITEL part number
Network type
Network voltage
Max. operating voltage
TOV withstand
Operating current
---
--
Ft
---
Ft
--- V
---
Ft
---
---
GSG
MCOV
UT
Ic
leakage current at Uc
Follow current
Nominal discharge current
Ft
---- V
------------
---
------------
60
------------
------------
---
65
------------
34
Buzzer alarm
M15-120N
Single phase
120 Vac
150 Vac
150 Vac
M15-230N
Single phase
230 Vac
275 Vac
275 Vac
M15-480N
Single phase
480 Vac
550 Vac
550 Vac
M15-120SP
Split phase
120 Vac
150 Vac
150 Vac
M15-600DC
DC
600 Vdc
800 Vdc
800 Vdc
M50-120Y
3-phase
120 Vac
150 Vac
150 Vac
None
None
None
None
None
None
None
5 kA
None
5 kA
None
20 kA
If
In
None
5 kA
None
5 kA
None
5 kA
Imax
15 kA
15 kA
15 kA
15 kA
15 kA
50 kA
VPR
Up
Isccr
600 V
800 V
25 kA
1000 V
1200 V
25 kA
1800 V
1400 V
2300 V
700 Vac
2000 V
25 kA
1600 V
25 kA
2500 V
25 kA
1200 Vac
100 kA
15 x 8/20 s impulse
Associated disconnectors
Thermal disconnector
Fuses
Installation ground fault breaker, if any
internal
40 A
Type S or delayed
Mechanical characteristics
Dimensions
see diagram
Connection
Disconnection indicator
Mounting
Operating temperature
Environmental rating
Housing material
LED off
Bulkhead (3/4") or Wall mount
-40/+85 C
IP66
Thermoplastic UL94-V0
see diagram
wire 15 AWG (1,5 mm),
Long. 600 mm
LED off and audible alarm
Bulkhead (3/4)
-40/+85C
IP66
Stainless Steel
Standard Compliance
CEI 61643-1
EN 61643-11
UL 1449 3rd Edition
Part number
77
International
Europe
USA
730105
730201
730301
TELEPHONE LINE
Surge protectors
78
Protecting telecommunication
equipment
Telecom devices (PBX, Modems, Terminals..) are especially exposed
to lightning surges. CITEL offers a range of surge protectors dedicated to the protecting of these types of telecommunication networks :
Surge protectors
matched with telecom line
analog
telephone
PCM/T2
Fa x
Mo
SDSL
SHDSL
dem
/ xD
SL
ISD N
PABX
Introduction
ISDN/T0
Voltage
Lines
Nominal
Residual
Diagram
CITEL products differ by their electrical diagrams and their mechanical congurations, adapted to the need of each type of network.
170 V
210 V
Standard protection
48 V
35 V
Enhanced protection
Reminder:
Devices connected to telecom or data networks, are also connected
to the AC distribution network : in order to ensure a coordinated protection, surge protectors must be installed on each inter-connected
networks.
6V
15 V
Enhanced Protection
Low capacitance
170 V
210 V
Enhanced protection
SDSL, SHDSL
Mechanical configurations
Surge protectors for telecom networks are designed to t into existing installations. So, CITEL surge protectors are available with many
different mounting options:
Mounting on telecom MDF
Mounting on DIN rail
Insertion in connection strips
Wall mounting
Plug-in on termination outlets
The decision whether or not to use surge protection would be determined by taking a simplied risk assessment (see Risk analysis
paragraph), or by detailed risk assessment (as the one included in IEC
61643-22 standard), or by specic installation conditions as :
Conditions
Recommendation
Systematic protection
Protection in long or inter-building
lines
Systematic protection
79
All Citel telephone and data line surge protectors are based on reliable
multistage hybrid design that combines a high discharge current capacity
with fast response time.
All Citel telephone and data line surge protectors use a combination of
a 3-electrode gas discharge tube and fast clamping diodes, in order to
provide:
A nominal discharge current (repeated without destruction) greater
than 5 kA @ 8/20 s impulse
An ultrafast response time < 1 ns
Safety operation in end of life
(Fail-safe behaviour)
Low insertion losses to not disturb the transmission signal.
Equipment to be protected
Industrial or business installations are equipped with many different
types of sensitive terminals, which must be protected against transient voltages, such as:
Industrial process equipment
SCADA systems (Supervisory Control And Data Acquisition)
Transmission systems
I/O cards
Interfaces, converters
Probes
Actuators
Access control system
Fire detection system, Displays
Many data transmissions (or eldbus) exist on the market. The table
below provides relevant CITEL surge protector model (DLA series :
Din rail pluggable module, and DLU series : Din rail monobloc module) in relation to the type of data transmission.
Network
Wiring
DLU
DLA
4-20 mA
1 pair
DLU-24D3
DLA-24D3
Profibus-FMS
1 pair+Shield
DLU-12D3
DLA-12D3
Profibus-PA
1 pair+Shield
DLU-48D3
DLA-48D3
Profibus-DP
1 pair+Shield
DLU-12DBC
DLA-12DBC
Interbus
1 pair+Shield
DLU-12D3
DLA-12D3
Foundation Fieldbus-H1
1 pair+Shield
DLU-12D3
DLA-12D3
Foundation Fieldbus-H2
1 pair+Shield
DLU-48DBC
DLA-48DBC
WorldFIP
1 pair+Shield
DLU-48DBC
DLA-48DBC
Fipway
1 pair+Shield
DLU-48DBC
DLA-48DBC
LONworks
1 pair+Shield
DLU-48DBC
DLA-12DBC
Batibus
1 pair+Shield
DLU-12D3
DLA-12D3
RS485
1 pair+Shield
DLU-12D3
DLA-12D3
RS422
2 pairs
DLU2-06D3
2 x DLA-06D3
RS232
4 wires
DLU2-12D3
2 x DLA-12D3
Mechanical configuration
CITEL surge protectors for industrial data networks are designed to
t on symmetrical DIN rail.In order to offer a large range of solutions,
the surge protectors are available in various congurations :
Number of protected wires : from 1 wire to 2 pairs.
Transmission and protection of the shield wire
Plug-in modules : Version with removable module to ease the
maintenance process.
GDT
D
Equipt
The systematic use of 3-electrode discharge tubes provides optimum protection through simultaneous sparkover.
This set of characteristics is essential for optimum reliability of the protected equipment whatever the incident or disturbance.
Various protection diagrams are available according to requirements and
the type of network to be protected:
Standard protection, used mainly for the analog telecom network
(PSTN)
Enhanced protection, for very low voltage transmission lines.
Line+Shield Protection : Transmission and protection for the shield
wire.
K20 protection complying with the ITU-T K20 International
recommendation
Low capacitance protection for high bit rate links (> 1 Mbit/s)
Cat 5 or Cat 6 surge protection : designed for very high bitrate LAN
(up to 1000 Mbit/s).
See list of diagrams, page 82.
Standards
Tests procedures and installation recommendations for communication
line surge protectors must comply the following standards:
International:
- IEC 61643-21 : Tests of surge protectors for communication lines.
- IEC 61643-22 : Choice/installation of surge protectors for communication lines.
France:
- NF EN 61643-21 : Essais applicables aux parafoudres de communication.
- Guide UTE C 15-443 : Choice/installation of surge protectors
80
Installation
Low Risk
< 2,5
Single building
Short
Underground
Low
No
Never
Low
Low
Low or acceptable
High Risk
> 2,5
Multiple buildings
Long
Overhead
High
Yes
Already
High
High
Expensive or unacceptable
81
Maintenance
CITEL data line surge protectors require no maintenance or replacement. They are designed to withstand repeated and heavy impulse currents without damage.
Nevertheless a controlled fail-safe mode (short circuit to earth) is
planned in case of surges exceeding the parameters of the surge protectors:
Protective short-circuit occurs in the following cases :
- sustained contact between the telecom line and a power line.
- exceptionally heavy lightning impulse current.
In these rare cases, the surge protectors will go denitively in short-circuit. By this way, it protects the terminal equipment and warns about its
failure. To reactive the line, the surge protector must be replaced.
The basic parameters of the surge protector for datalines could be controlled with dedicated testers.
Typical diagrams
Standard Protection
Reinforced Protection
R
K1
DBC
P
R
Protection + Shield
CTP
D3
DBC
D3
P
D
CTP
DBC
PB
3-electrode GDT
Protection
2-electrode GDT
Protection
2-pole MOV
Protection
3-pole MOV
Protection
V
PB
V
V
V
Low capacitance
3- pole diode
CAT6 Protection
Grounding
Line continuity
DBC
DBC
V
82
DLA -xxx
DLA2-24D3
DLA-170
DLA
DLA = 65
DLA2 = 68
DLA2
13
18
9 11
10 12
DIN rail
DIN rail
90
DLA
standard version
R
1
D
Ligne
DLAW
specic version
Plug-in
module
DLAM
1
Equipt
PB
DLA2
standard version
Plug-in
module
DLAWM
D
R
Ligne
Equipt
2
R
PB
Earth possible
on rail DIN
11
3
83
8
D
Ligne
Plugable
module
DLA2M
Earth possible
on rail DIN
PB
Equipt
12
4
10
Earth possible
on rail DIN
Characteristics
Configuration
1 pair
2 pairs
DLA-170
DLA2-170
DLA-48D3
DLA2-48D3
DLA-24D3
DLA2-24D3
DLA-48DBC
DLA2-48DBC
Utilisations type
Telephone line
ADSL
SDSL-SHDSL
ISDN-T0
48 V line
Leased line
4-20 mA
DLA-12D3
DLA2-12D3
DLA-06D3
DLA2-06D3
DLA-06DBC
DLA2-06DBC
RS422
MIC/T2
10BaseT
150 V
48 V
24 V
48 V
12 V
6V
6V
170 V
53 V
28 V
53 V
15 V
8V
8V
300 mA
300 mA
300 mA
300 mA
300 mA
300 mA
300 mA
Max. frequency
> 10 MHz
> 3 MHz
> 3 MHz
> 20 MHz
> 3 MHz
> 3 MHz
> 20 MHz
220 V
70 V
40 V
75 V
30 V
20 V
25 V
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
Short-circuit
Short-circuit
Short-circuit
Short-circuit
Short-circuit
Short-circuit
Short-circuit
6402011
6401011
640121
640211
640111
640131
End of life
Mechanical characteristics
Conguration
Mounting
Dimensions
see drawing
Wiring
Housing material
Thermoplastic UL94-V0
Earth Connection
Spare module
DLA : DLAM-xxx
DLA2 : DLA2M-xxx
Versions
Standard compliance
NF EN 64643-21 (France)
UL497A&B (USA)
Part number
DLA
6406011
6403021
6403011
DLA2
640611
640312
640311
640421
LISTED
84
Monobloc housing
DLU -xxx
Bit rate (D3 or DBC)
DLU2-48DBC
Nominal voltage
: 1 pair
2 : 2 pairs
DLU-170
58
Line
90
DLU
DLU2
18
18
Equipt
DLU
1-pair version
PB
1
D
Line
DLU2
2-pair version
DIN rail
DIN rail
Equipt
2
Line
85
3
D
Earth possible
on DIN rail
Earth on DIN
rail
Equipt
Characteristics
Configuration
1 pair
2 pairs
DLU-170
DLU2-170
DLU-48D3
DLU2-48D3
DLU-48DBC
DLU2-48DBC
DLU-24D3
DLU2-24D3
DLU-12D3
DLU2-12D3
DLU-06D3
DLU2-06D3
DLU-06DBC
DLU2-06DBC
Typical Application
Telephone
line
ADSL
SDSL - SHDSL
48 V line
Fipway
WorldFIP
Fieldbus-H2
4-20 mA
24 V line
Probus-FMS
Interbus
Fieldbus-H1
Batibus
RS232, RS485
RS422
6 V line high
bitrate
T2 - T1
10BaseT
6V
150 V
48 V
48 V
24 V
12 V
6V
170 V
53 V
53 V
28 V
15 V
10 V
10 V
300 mA
300 mA
300 mA
300 mA
300 mA
300 mA
300 mA
Max. Frequency
> 10 MHz
> 3 MHz
> 20 MHz
> 3 MHz
> 3 MHz
> 3 MHz
> 20 MHz
220 V
70 V
75 V
40 V
30 V
20 V
25 V
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
Short-circuit
Short-circuit
Short-circuit
Short-circuit
Short-circuit
Short-circuit
Short-circuit
End of life
Mechanical characteristics
Conguration
Mounting
Dimensions
see drawing
Wiring
Housing material
Thermoplastic UL94-V0
Connection
Earth connection via DIN rail (DLU, dlu2) and screw terminal (DLU)
Standard compliance
NF EN 61643-21 (France)
UL497A&B (USA)
Part number
DLU
640505
640504
640514
640503
640502
640501
640511
DLU2
640405
640404
640434
640401
640403
640402
640431
LISTED
86
UL497 A&B
B480
B 80-xx
Bit rate (D3 or DBC)
Nominal voltage
1 : 1 pair
2 : 2 pairs
4 : 4 pairs
B180
B180
B280-B480
68
35
50
25,2
60
2
1
Equipt
2
Line
120
Equipt
22
1
Line
1-pair version
A
B
R
Line
Equipt
Line
D3
Equipt
Line
Equipt
DBC
R
87
Characteristics
Configuration
1-pair unit
2-pair unit
4-pair unit
B180-T
B280-T
B480-T
B280-48D3
B480-48D3
B180-24D3
B280-24D3
B480-24D3
B180-06D3
B280-06D3
B480-06D3
B280-06DBC
B480-06DBC
Telephone line
ADSL
SDSL - HSDSL
ISDN-T0
48 V line
Leased line
4-20 mA
RS232
RS485
RS422
T2 - T1
10BaseT
Conguration protected
- B180...
- B280...
- B480...
1 pair
2 pairs
4 pairs
1 channel
2 channels
LS 2 wires / 1 pair
LS 4 wires / 2 pairs
2 LS 4 wires/2x2pairs
2 wires
4 wires
8 wires
1 pair
2 pairs
4 pairs/ 2x2 pairs
1 channel
2 channels
150 V
48 V
24 V
170 V
12 V
6V
6V
53 V
28 V
15 V
8V
8V
300 mA
300 mA
300 mA
300 mA
300 mA
300 mA
Max. frequency
> 10 MHz
> 3 MHz
> 3 MHz
> 3 MHz
> 3 MHz
> 20 MHz
220 V
70 V
40 V
30 V
20 V
25 V
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
20 kA
20 kA
20 kA
20 kA
20 kA
20 kA
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
Application
8/20s impulse - 5 kA
Type of diagram
End of life
Short-circuit
Short-circuit
Short-circuit
Short-circuit
Short-circuit
Short-circuit
Mechanical characteristics
Mounting
Dimensions
see diagrams
Wiring
Housing material
Thermoplastic UL94-V0
Spare circuit
Standard compliance
NF EN 61643-21 (France)
UL497A&B (USA)
Part Number
1-pair unit B180
510602
510302
510202
510102
72726
72774
72773
72772
72771
72751
72746
72794
72793
72792
72791
72798
LISTED
88
E280 series
B
R
55,8
Line
Equipt
D3
Line
C
t
CTP
Line
18,5
2b 2a 1b 1a
1a 1b 2a 2b
Line
Equipt
Line
Equipt
P2
P1
P1
CTP
Line
EQUIP
DBC
P2
K1
R
Equip
Equipt
Characteristics
CITEL part number
E280-TM
E280-K20
E280-48D3M
E280-24D3M
E280-12D3M
E280-06D3M
E280-06DBC
Application
Telephone line
K20 std
ISDN-T0
Telex
Leased line
4-20 mA
RS232
RS485
RS422
T2 - T1
10BaseT
150 V
150 V
48 V
24 V
12 V
6V
6V
170 V
190 V
53 V
28 V
15 V
8V
8V
300 mA
150 mA
300 mA
300 mA
300 mA
300 mA
300 mA
Max. frequency
> 10 MHz
> 3 Mhz
> 3 MHz
>3 MHz
> 3 MHz
> 3 MHz
> 20 MHz
220 V
260 V
70 V
40 V
30 V
20 V
25 V
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
5 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
2.5 kA
2.5 kA
2.5 kA
2.5 kA
2.5 kA
2.5 kA
2.5 kA
Type of diagram
K1
End of life
short-circuit
short-circuit
short-circuit
short-circuit
short-circuit
short-circuit
71183
71182
71181
71171
Mechanical characteristics
Mounting
Dimensions
see drawing
Connectique
Housing material
Thermoplastic UL94-V0
Standards compliance
NF EN 61643-21 (France)
UL497A (USA)
Part Number
E280
89
LISTED
71186
71192
71184
BN , FPSU , MMP
BN series : 8, 16 or 32 pairs
Metal enclosures for E280
MMP
FP series : 10 or 25 pairs
Wall mounting plate
FPSU
Dimensions
(in mm)
140
166
66
107
FPSU04 W
113
145
FPSU08
410
71
188
Diam. 4,5
230
1a
40
1b
2a
2b
3a
3b
4a
4b
1a
1b
Equipement
2a
2b
3a
3b
130
Ligne
External
lines
4a
4b
Protected
equipment
BN08
MMP
FPSU16
BN32
BN16
Characteristics
Format
CITEL part number
Metal enclosures
BN08
BN16
Brackets/boards
BN32
FPSU04
FPSU08
FPSU16
Strip
FP10
FP25
MMP
16
32
16
10
25
16
13
I/O connection :
Screw terminals
Quick connect 66 (USA)
ATT110 (USA)
BN08V
-
BN16V
-
BN32V
-
FPSU04V
-
FPSU08V
-
FPSU16V
-
FP10QC66
FP10-110
FP25QC66
-
MMP
-
Mounting system
Wall
Wall
Wall
MDF*
DIN rail
MDF*
DIN rail
MDF*
DIN rail
Wall
Wall
MDF*
Earth connection
Earth pin
Part number
Screw terminals
Quick connect
ATT110
71347
-
71356
-
71377
-
71442
-
71462
-
71472
-
71480
-
*) Compatible with MDF profile : PAO15001 (Infra+), HPU (3M-Pouyet), 09649 (Alcatel) and CITEL profile
90
KP10
KP1
Fast installation
Fast Maintenance
DP80-TW
KP10
KP1
123
22
20
Line
Line
Equipt
40,2
9,5
P
PTC
DP80-TW
103
FS
P
Line
99
FS
PTC
12,8
43
20
10
19
21
Ground bus
Characteristics
CITEL part number
KP1-T
KP1-06DBC
KP10-T
KP10-06DBC
DP80-TW
Application
Analog line
ADSL
T2 - T1
10BaseT
Analog line
ADSL
T2 - T1
10BaseT
Analog line
ADSL
Conguration
1 pair
1 pair
10 pairs
10 pairs
1 pair
150 V
6V
150 V
6V
150 V
170 V
8V
170 V
8V
170 V
300 mA
300 mA
300 mA
300 mA
100 mA
Max. frecuency
> 10 MHz
> 20 MHz
> 10 MHz
> 20 MHz
> 3 MHz
230 V
25 V
230 V
25 V
< 700 V
5 kA
5 kA
5 kA
5 kA
10 kA
End of life
short-circuit
short-circuit
short-circuit
short-circuit
Type of diagram
Mechanical characteristics
91
Mounting
Dimensions
see drawing
Contact
tinned copper
Housing material
Thermoplastic UL94-V0
Part Number
85186
see drawing
85259
Equipt
85126
DBC
Equipt
MJ8, MJ6-1T
Quick installation
MJ6-1T
MJ8-170V
MJ8
58
27
34
44
54
25
25
Mounting Flange
Screw lug
Line
Equipment
Line
D
Equipment
Characteristics
CITEL part number
MJ6-1T
MJ8-ISDN
MJ8-170V
Application
Max. operating voltage (Uc)
Max. line current (IL)
Max. frequency
ISDN
60 Vdc
300 mA
> 10 MHz
2 pairs
(3-6) (4-5)
PSTN/ADSL
170 Vdc
300 mA
> 10 MHz
2 pairs
(1-2) (3-6) (4-5) (7-8)
2500 A
2500 A
500 A
2000 A
500 A
2000 A
RJ11
RJ11
Mounting Flange,
Ground wire
Metal
Shielded RJ45
Shielded RJ45
Shielded RJ45
Shielded RJ45
Pin outs
Nominal discharge currents (@8/20s)
- Line/Line
- Line/Ground
Connections:
- Input
- Output
Ground Connection
Enclosure
Metal
Standard Compliance
NF EN 61643-21 ( France)
UL497A (USA)
Part number
560402
560209
560203
LISTED
92
93
DATA LINE
Surge Protectors
94
Mechanical configuration
The surge protectors for data-processing networks are designed to
fit with the existing installation. In consequence, the surge protectors
are equipped with standard connectors (e.g. : RJ45) and are available
in a single enclosure to protect a terminal equipment, or in 19 rack
unit format to protect at the hub level.
Protecting
Video Data Transmission
Video transmission lines (surveillance cameras) are regularly subjected to transient surges due to the nature of their distributed application. In order to insure the integrity of these installations, the application of dedicated SPDs at the equipment level (cameras) as well as at
the Digital Recording Devices (DVRs) is absolutely necessary.
Configuration
CITEL Surge protector for video transmission can be adapted to the
different configurations:
Analog camera:
CITEL Surge protector for video transmission can be adapted to
the different configurations.
MSP-VM-2P
CNP
IP camera:
The MSP-VM/R combines ETHERNET and Power Supply protection.
MSP
VM/R
MSP-VM/R
Performances
Ethernet network surge protectors are designed for computer
networks with very fast data transfer speeds up to 1 Gbit/s for the
Category 6 networks. In order to cover the many various types of
networking applications, CITEL offers a complete range of surge protectors adapted to the most important networks:
Category 5 and 5E
Category 6
PoE network
Standard
Surge protectors for data network are in compliance with
IEC 61643-21.
95
MJ8-POE
Standards
Video transmission network surge protectors are in compliance with
IEC 61643-21.
Installation
Mounting
On Rail
or by flange
RJ45 connection
Just a cable to be connected
Ground connection
via DIN Rail
Performances characteristics
0
20
100
(MHz)
Insertion
Loss
1.2 dB @ 100 MHz
100
100
(MHz)
Return Loss
20 dB @ 100 MHz
0
20
(MHz)
NEXT
45dB @ 100 MHz
20
40
40
40
60
60
(dB)
(dB)
60
80
(dB)
96
MJ8 series
Shielded enclosure
RJ45 connectors
Bi-directional
MJ8-CAT5E
MJ8-C6
MJ8-C6
44
23
90
54
38
Mounting Flange
DBC
Screw lug
MJ8-CAT6
90
23
Line
RJ45
280 mm
Equipment
38
RJ45
2700 mm
Characteristics
CITEL part number
MJ8-CAT5E
MJ8-CAT6
MJ8-C6
MJ8-12V
Application
Ethernet
Ethernet Cat.6
Ethernet Cat.6
12 V signal
1000 Mbps
8 Vdc
1A
(1-2) (3-6)
(4-5) (7-8)
1000 Mbps
7.5 Vdc
1A
(1-2) (3-6)
(4-5) (7-8)
1000 Mbps
6 Vdc
1A
(1-2) (3-6)
(4-5) (7-8)
30 Mbps
60 Vdc
1A
(3-6) (4-5)
<500 A @ 8/20 s
2000 A @ 8/20 s
<100 A @ 8/20 s
100 A @ 8/20 s
< 500 A
2000 A
RJ45 Connectors
RJ45 Connectors
4 pairs + ground
RJ45 Connectors
RJ45 Connectors
4 pairs + ground
Metal
Plastic
Screw Lug, Din Rail Clip or
Ground wire
Mounting Flange
IEEE 802-3af and 3av (transmission)
IEC 61643-21 (surge withstand)
Plastic
Ground wire
Metal
Screw Lug, Din rail clip or
mounting ange
IEC 61643-21
560201
6184
560205
Max. DC Signal
Pin outs
Nominal discharge currents:
- Line/Line
- Line/Ground
Mechanical characteristics
Connections:
- Input
- Output
Pin out
Enclosure
Ground Connection
Standard Compliance
Part number
97
6149
MJ8-POE
POE compatible
2 kA discharge capability
UL497A
Characteristics
(in mm)
34
44
MJ8-POE-A
54
Application
Mounting Flange
Screw lug
MJ8-POE-B
1000 Mbps
1000 Mbps
60 Vdc - 650 mA
Pin outs
(1-2) (3-6)
(4-5) (7-8)
<500 A @ 8/20 s
2000 A @ 8/20 s
Mechanical characteristics
Connexions:
- Input
- Output
Pinout
Line
DBC
Equipment
RJ45 shielded
RJ45 shielded
8 wires + shielding
Enclosure
Ground Connection
Metal
Screw Lug, Din Rail Clip or Mounting Flange
Standard Compliance
Part number
581519
51518
LISTED
P : 3-electrode gas tube
DBC : 3-pole Low capacitance diode
98
CMJ8-POE
POE compatible
Outdoor application
2 kA discharge capability
UL497A
CMJ8-POE-A
CMJ8-POE-A/PCB
Characteristics
(in mm)
CMJ8-POE-A
Application
33.02
139.7
111.76
60 Vdc - 650 mA
Pin outs
(1-2) (3-6)
(4-5) (7-8)
CMJ8-POE-B
<500 A @ 8/20 s
2000 A @ 8/20 s
<500 A @ 8/20 s
2000 A @ 8/20 s
Mechanical characteristics
91.44
35.56
Connections:
- Input
- Output
RJ45 shielded
RJ45 shielded
Pinout
8 wires + shielding
Protection class
IP65
55.88
6.35
Part number
6211
LISTED
GDT
Line
99
DBC
Equipement
6212
DDP series
Multiples connectors
Easy mounting
DDP-25
DDP-H4
One-pair Protection
84
84
32
169
142
Fig.A
32
SD : Steering diode
SAD : Silicon avalanche diode
Fig.B
Characteristics
CITEL part number
DDP-xx-E
DDP-xx-E-C5
DDP-xx-T
DDP-xx-B
100 BaseT
RS232
CSU /DSU
Non span T1
40 Mbps
DDP-xx-G
10BaseT, RS422,
RS485, RS423,
Ethernet
40 Mbps
100 Mbps
40 Mbps
7.5 Vdc
7.5 Vdc
18 Vdc
60 Vdc
240 Vdc
750 mA
750 mA
750 mA
750 mA
750 mA
(at 10/1000s)
132 A
132 A
60 A
50 A
75 A
< 40 pF
< 40 pF
< 40 pF
< 75 pF
< 95 pF
Application
Dial-up
Modem
Fax
40 Mbps
Mechanical characteristics
Conguration available (xx)
Pinout
Installation
Velcro retainer
Ground connection
Connections depending
of congurations (xx)
Standard compliance
100
PCH series
19 Rack mounted
12, 24 et 48 ports
89
16
73
Characteristics
CITEL part number
PCHxxx-C6
PCHxxx-POE-A
PCHxxx-POE-B
PCH12-RJ45-B PCH12-RJ45-G
Application
100/1000BaseT
CAT5/5E/6
Ethernet
POE mode A
POE mode B
ISDN-T1
DDN
RTC
ADSL
40 Mbps
40 Mbps
60 Vdc
240 Vdc
1000 Mbps
1000 Mbps
7,5 Vdc
60 Vdc
750 mA
750 mA
(@ 10/1000s waveform)
100 A
50 A
<8 pF
<8 pF
100 Mbps
Pin 1,2,3,6 : 7,5 Vdc
Pin 4,5,7,8 : 60 Vdc
750 mA
Pin 1,2,3,6 : 132 A
Pin 4,5,7,8 : 50 A
<8 pF
12, 24 or 48
12, 24 or 48
12, 24 or 48
Pinout
Installation
Ground connection
Standard compliance
101
110 Block
RJ45 Female
8 wires per connector
Flush mount
Screw lug or Mounting ange
UL497B
IEEE 802-3af (transmission)
750 mA
750 mA
50 A
75 A
<75 pF
<95 pF
12
12
RAK series
16 or 32 ports
Dimensions
Surge protector
circuit 1 port
(in mm)
483
19
Format A
80
Format B
Format C
41
Characteristics
CITEL Part number
RAKxx-E-C5E
RAKxx-E-C6
RAKxx-E-C6-60V RAKxx-T
RAKxx-B
RAKxx-G
RAKxx-POE-A
RAKxx-POE-B
RAK16-BNC
RAK16-CMS
Application
100/1000BaseT
RS422, RS485,
RS423, Ethernet
High voltage
ethernet
RNIS
RTC
ADSL
POE
mode A
POE
mode B
CCTV
Cable TV
Satellite
1000 Mbps
Pin 1,2,3,6 : 7.5Vdc
Pin 4,5,7,8 : 60 Vdc
750 mA
Pin 1,2,3,6 : 132 A
Pin 4,5,7,8 : 50 A
1000 Mbps
1000 Mbps
7,5 Vdc
90 Vdc
750 mA
750 mA
20 kA
RS232
1000 Mbps
1000 Mbps
100 Mbps
40 Mbps
40 Mbps
100 Mbps
7,5 Vdc
60 Vdc
18 Vdc
60 Vdc
240 Vdc
60 Vdc
<40 pF (-C5E)
<8 pF (-C6)
750 mA
750 mA
750 mA
750 mA
750 mA
45 A
60 A
50 A
75 A
50 A
<25 pF
<15 pF
<40 pF
<75 pF
<95 pF
16 or 32
yes
A
16 or 32
yes
A
16 or 32
yes
A ou C
16 or 32
yes
A
16 or 32
yes
A
RJ45 Female
RJ45 Female
8 wires per connector
Flush mount or Stand off
Screw lug or Mounting ange
UL497B
IEEE 802-3af (transmission)
<25 pF
(ethernet lines only)
16 or 32
yes
A
132 A
(8/20s waveform)
<30 pF
<1 pF
16
no
B
16
no
B
BNC (Female)
BNC (Female)
N/A
F (Female)
F (Female)
N/A
102
DD series
DD15-24V
Secondary protection
DD9-24V
Characteristics
(in mm)
DD9-24V
61
CITEL
30,5
DD9-24V
DDxx-6V*
Application
RS422, RS485
RS232, 4-20mA
Connector D-Sub 25
DD25ESD-6V
DD25ESD-24V
Connector D-Sub 15
DD15-6V
DD15-24V
Connector D-Sub 9
DD9-6V
DD9-24V
6V
15 V
61
CITEL
40,6
Uc
DDxx-24V*
Capacitance
<30 pF
<30 pF
<40 Mbps
<40 Mbps
Clamping voltage
Up
7.5 V
18 V
In
400 A
300 A
Connector wiring
Mounting
on D-sub connector
on D-sub connector
Earthing
by wire
by wire
Mechanical characteristics
DD15-24V
61
DD25-24V
Housing material
thermoplastic
thermoplastic
Dimensions
see drawings
see drawings
DD25ESD-xxV
6146
6145
DD15ESD-xxV
6215
6214
DD9ESD-xxV
6148
6147
Part Number
CITEL
53,5
DD25-24V
DD25
DD15
DD9
103
1
D
13
13
14
14
15
15
23
23
24
24
25
25
MSP-VM-2P series
Other versions :
- Data 1 pair : MSP-VM..
- Cat.5 - RJ45 : MSP-VM../R
Characteristics
(in mm)
55
37
64
90
MSP-VM24-2P
MSP-VM-120-2P MSP-VM-230-2P
Nominal voltage
Un
24 Vdc
120 Vdc
230 Vdc
Maximum voltage
30 Vdc
150 Vdc
255 Vdc
Line current
Uc
IL
5A
5A
5A
In
5 kA
5 kA
5 kA
Imax
10 kA
10 kA
10 kA
Protection level
Up
0.3 kV
0.8 kV
1.2 kV
Connection
Failure mode
Data 2 pairs
Maximum voltage
Nominal discharge current
Maximum discharge current
Uc
In
Imax
Protection level
Up
8 Vdc
2.5 kA
5 kA
8 Vdc
2.5 kA
5 kA
8 Vdc
2.5 kA
5 kA
20 kV
20 kV
20 kV
Connection
Failure mode
Video
L
V1
V3
LED
Powerline
V1
N
D1
Video signal
Shield
Maximum voltage
Uc
6 Vdc
6 Vdc
6 Vdc
In
5 kA
5 kA
5 kA
Imax
10 kA
10 kA
10 kA
Protection level
Up
20 V
20 V
20 V
Connection
Failure mode
Mechanical characteristics
G1
Dimensions
Tx+
G2
D2
TxRx+
Dataline
G3
D3
See diagram
Housing material
Anodized aluminum
Mounting
Rx-
V : Varistor
LED : status indicator
D : Clamping diode network
G: Gas tube
Other versions
Alimentation
24 Vac/dc
120 Vac
230 Vac
Data 1 pair
+ Video BNC
MSP-VM24
MSP-VM120
MSP-VM230
Ethernet Cat.5 by
RJ45 connector
MSP-VM24/R
MSP-VM120/R
MSP-VM230/R
104
Multiples connectors
Easy installation
CXC09-B/MF
CNP06-B/FM
Characteristics
(in mm)
CXC06
CNP06
Frequency Range
DC-70MHz
DC-100MHz
Technology
GDT+Diode
GDT+Diode
Insertion Loss
0.6 dB
0.5 dB
Return Loss
20 dB
>20 dB
VSWR
<1.2:1
< 1.2:1
39,5
10 kA
20 kA
63,5
5V
5V
Max power
6W
4W
Impedance
50 ohms
50/75 ohms
CXC...-B/FM
23
Mechanical characteristics
CNP
24
Connectors
BNC
BNC, TNC
Grounding
Ground wire
Ground wire
Environmental Rating
IP65
IP20
Housing material
Brass
Metal + plastic
Mounting
cable
plate
Cxx06-B/FM
6301341
64270
Cxx06-B/MF
630134
632611
Part number
43
61
CXC / CNP06
R
P
DBC
105
32
48
DIN-BNC series
DIN-BNC
SPDINRAK
SPDINRAK
67,8
25
439,4
35
23
482,6
408,9
DIN Rail clip
F : Fuse
PB : 2-electrode gaz tube (*for DIN-BNC-HD)
DBC : 3-pole low capacitance diode
Characteristics
CITEL part number
DIN-C6
DIN-T
10/100/1000 BaseT
RS422, RS423
1000 Mpbs
RS232
RS485
100 Mbps
7.5 Vdc
DIN- B
DIN-G
40 Mbps
RTC
ADSL
40 Mbps
18 Vdc
60 Vdc
750 mA
750 mA
(@ 10/1000s)
100 A
60 A
< 40 pF
< 40 pF
Application
RNIS
DIN-BNC
DIN-BNC-HD
Video signal
Video signal
1000 Mbps
1000 Mbps
240 Vdc
2.7 Vdc
7.5 Vdc
750 mA
750 mA
750 mA
750 mA
50 A
75 A
132 A
25 kA (8/20s)
< 75 pF
< 95 pF
< 25 pF
< 25 pF
Mechanical characteristics
Connectors
RJ45
RJ45
RJ45
RJ45 or RJ11
Pins protected
Connections :
- input
- output
Pinout
all
all
all
4 center
N/A
N/A
BNC Female
BNC Female
N/A
BNC Female
BNC Female
N/A
Installation
Ground connection
DIN-rail grounded
UL497B
IEEE 802-3a (Transmission)
Standard compliance
106
107
COAXIAL RF
Surge Protectors
108
RF Surge Protection
Protection of radiocommunication
equipment
Lightning
Rod
Warning
Light
1
2
3
4
5
E/R
Antenna
GSM
Antenna
conducto
AC/DC
LPS down
AC distribution
5
T.B.T.48V Power
AC
Power
Telecom
Technical
Cabinet
44
4
Coaxial Cables
Control
Junction
Earthing Interconnexion
LPS Earthing
< 10 ohms
Earthing
Lightning
Rod
GSM
Antenna
LPS down
conductor
Outdoor cabinet
Equipment
AC Power
Network
Coaxial cables
Control
Junction
Shielding earthing
Interconnection Earthing
Earthing
109
LPS Earthing
< 10 ohms
RF Surge Protection
P8AX
Antenna
Main characteristics (CXP-DBC) :
DC Block feature
Insertion losses < 0.15 dB
VSWR < 1.2
Imax : 10 kA (8/20s)
Bandwidth : 125 - 1000 MHz
Connectors : N, BNC
Equipment
Earth
P8AX-VG
Antenna
Equipment
Earth
PRC
Antenna
Equipment
CXP-DCB
Earth
Antenna
Equipment
Main characteristics :
Insertion losses < 0.2 dB
VSWR < 1.2
Bandwidth :
- 400-500 MHz
- 870-950 MHz
- 1700-1950 MHz
- 1700-2200 MHz
- 870-220 MHz
Imax : up to 100 kA (8/20s)
Connectors : 7/16, N, BNC, TNC, 7/8 cble
F (Ghz )
+ 0. 2
0.2 dB/di v.
-1.6
0.51
1.52
2.53
3.54
4.55
5.56
6.57
110
RF Surge Protection
Comparison
Table below allows comparison between the 3 technologies of RF coaxial surge protectors, in order to select the right solution regarding
the application and the requirements.
Technology
Gas tube
DC Block
Quarter wave
CITEL series
P8AX
CXP-DCB
PRC
Principle
Residual voltage
Sparkover
Sparkover + Filtering
Adapted short-circuit/selective band lter
from 70V to 600 V in relation with the dV/ < 100 V
< 20 V
dt, then arc regime (short-circuit of the line Short-circuit of the line in the full bandwidth RF signal not disturbed during the protecin the full bandwidth). RF signal disturbed : RF signal disturbed during the protection tion operation.
during the protection operation. Except for operation.
the option VG
Bandwidth
DC injection
8/20s discharge current
capability
Life expectancy
Connectors
Quater Wave
U
x 100 V
x 10 V
t
111
LF : Low Frequency
MF : Medium Frequency
HF : High Frequency
VHF : Very High Frequency
UHF : Ultra High Frequency
SHF : Super High Frequency
Tetra, Tetrapol
GSM850
Tetra
GSM 900
GPS
GSM 1800
GSM 1900
DECT
WCDMA/TD-SCDMA
UMTS (IMT-2000)
WLL (WiMax)
30-300 kHz
300-3000 kHz
3-30 MHz
30-300 MHz
300-3000 MHz
3-30 GHz
380-512 MHz
824-894 MHz
870-925 MHz
880-960 MHz
1575 MHz
1710-1785 MHz
1850-1990 MHz
1880-1900 MHz
1850-2025 MHz
1885-2200 MHZ
2400-5825 MHz
RF Surge Protection
Installation
The efciency of coaxial protectors is highly dependent on proper installation, in particular their connection to the earthing network of
the installation.
The following installations rules must be strictly observed to ensure
the efciency :
Well grounded
panel
Protected
side
3
2 types of mounting
Feedthrough mounting
Direct mounting of the surge protector on the grounded frame at the
installation entrance :
- perfect connection to the bonding network
- best location (conduction of the surge currents at the entrance of
the installation)
- good mechanical withstand.
Alternative mounting
- connection to the bonding network by wire (4 mm minimum and
shortest length possible).
Standards
IEC 61643-21
UL497C
UL497E
Mounting nut
Additional grounding
measures are necessary if the panel is
poorly grounded
Unprotected
side
Protected
side
Reference system
CITEL part number
P8AX09
P8AX15
P8AX25
P8AX35
P8AX50
Connectors
N
BNC
TNC
7/16
F
SMA
112
P8AX series
Waterproof
Removable GDT
DC-pass
Bi-directional protection
P8AX09-N/MF
Characteristics
(in mm)
P8AX09-N/MF
(example)
62.7
13.8
diam.
26
diam. 16.2
P8AX09
P8AX25
P8AX50
Frequency range
DC-4GHz1
DC-4GHz1
DC-4GHz
Technology
GDT
GDT
GDT
Insertion loss
0.2db
0.2db
0.2db
Return Loss
20 db
20 db
20 db
VSWR
<1.2:1
<1.2:1
<1.2:1
20 kA
20 kA
20 kA
Protection level
<600 V
<600 V
<1000 V
Max Power
25 W
190 W
780 W
Max Current
10 A
10 A
10 A
Impedance
50 ohms2
50 ohms2
50 ohms2
Connection Method
Series (bi-directional)
Mechanical characteristics
Coaxial line
Connectors
Grounding
Environmental Rating
IP65
Operating Temp
-40C to +85C
Operating Altitude
4,000 m
Relative Humidity
1
2
GDT
Material
GDT: 2-electrode gas discharge tube
Component
Body
Male contacts
Female contacts
Insulators
Material
Brass
Bronze
Bronze
PTFE
Cu Zn Sn
Gold/Silver
Gold/Silver
N/A
Surface Plating
113
P8AX-6G series
Waterproof
Removable GDT
DC-pass
Bi-directional protection
Characteristics
(in mm)
P8AX09-6G
P8AX25-6G
Frequency
DC-6GHz
DC-6GHz
Technology
Insertion loss
0.2db
0.2db
Return Loss
19 db
19 db
VSWR
<1.25:1
<1.25:1
20 kA
20 kA
Protection level
< 700 V
< 700 V
Max Power
70 W
240 W
Max Current
10 A
10 A
Impedance
50 ohms
50 ohms
Connection Method
Series (bi-directional)
Mechanical characteristics
Connectors
N, TNC, SMA
Grounding
Environmental Rating
IP65
Operating Temp
-40C to +85C
Operating Altitude
4,000m
Relative Humidity
Material
Component
Body
Male contacts
Female contacts
Insulators
Material
Brass
Bronze
Bronze
PTFE
Cu Zn Sn
Gold/Silver
Gold/Silver
N/A
Surface Plating
114
P8AX-6VG-N/MF
P8AX09-VG-N/MF
DC to 6 Ghz
Imax : 6 kA
VSWR 1.25
Feedthrough mounting
Bi-Directional protection
DC pass
Waterproof
Characteristics
(in mm)
68
20
54
25
P8AX09-6VG-N/MF
Frequency range
DC to 6 GHz
Impedance
50
VSWR
1.25
Insertion loss
0.2 dB
Max.input power
70 W
User current
6.A
User voltage
90 Vdc
6 kA
Protection level
Up
(1.2/50s, 4kV)
600 V
10 G
Mechanical specications
Dimension of
mounting hole
Dimensions
See drawing
Connectors
Mounting
On feedthrough or cable
Operating temperature
-40C to +85C
Waterproof degree
IP65 Min.
Coaxial line
Material
GDT
Component
Body
Male Contacts
Female contacts
Insulators
Material
Brass
Bronze
Bronze
PTFE
Cu Zn Sn
Gold
Gold
N/A
Surface Plating
V: Varistor
GDT: 2-electrode gas tube
115
Imax > 50 kA
No maintenance
PRC1800-7/16MF
Quater
Wave
71
Coaxial line
42.5
85
Characteristics
Rfrence CITEL
PRC822S
PRC900
PRC1800
PRC2100
PRC5800
Frequency Range
800-2200MHz
870-960MHz
1700-1950MHz
1800-2400MHz
4500-6000MHz
Technology
1/4 donde
1/4 donde
1/4 donde
1/4 donde
1/4 donde
Insertion Loss
0.2 db
0.2 db
0.2 db
0.2 db
0.2 db
Return Loss
20 db
20 db
20 db
20 db
20 db
VSWR
<1.2:1
<1.2:1
<1.2:1
<1.2:1
<1.2:1
50 kA
50 kA
Max Power
1500 W
1500 W
Max Current
N/A
N/A
N/A
N/A
N/A
Impedance
50 ohms
50 ohms
50 ohms
50 ohms
50 ohms
7/16, N, TNC
7/16, N, TNC
Caractristiques mcaniques
Connection Method
Series
Connectors
7/16, N
Grounding
Environmental Rating
IP65
Operating Temp
-40C to +85C
Operating Altitude
4,000 m
Relative Humidity
Material
Component
Body
F/M Contacts
Insulators
Material
Brass
Bronze
PTFE
Cu Zn Sn
Gold/Silver
Surface Plating
116
RoHS 6 compliance
Waterproof
Bi-directional
CXP09-NW/FF-DCB
CNP
CXP
82.4
39.8
30.8
24
32
CXP-DCB
48
diam. 5
P
43
61
Characteristics
CITEL PART NUMBER
CNP90TV
CNP230TV
CXP
CXP-DCB
Frequency Range
DC-1GHz
DC-1GHz
DC-1GHZ
Technology
Insertion Loss
0.6 dB
0.6 dB
0.5 dB
Return Loss
> 20 dB
> 20 dB
>18 dB
>20 dB
VSWR
< 1.35:1
< 1.35:1
< 1.3:1
< 1.3:1
20 kA
20 kA
20 kA
20 kA
Max Power
25 W
190 W
25 and 190 W
25 and 190 W
Max Current
0.5 A
0.5 A
0.5 A
Na
Impedance
75 ohms
75 ohms
50 ohms
50 ohms
Connectors
Grounding
Ground wire
Mounting Flange
Environmental Rating
IP20
IP65
Operating Temp
-40C to +85C
Mechanical characteristics
117
Operating Altitude
4,000 m
Relative Humidity
Screw xing
Grounding
BK-T
BK-N
BK-SMA
Mounting bracket
BK
Protected
side
No-protected
side
Part number
Connection
BK-D
66001
7/16
BK-F
66002
BK-N
66003
BK-SMA
66006
SMA
BK-T/BK-B
66007
part number
Packaging
P8AX reference
BBHF 90/20
927000107
Packing*10
P8AX09-xxx
BBHF 150/20
927000207
Packing*10
P8AX15-xxx
BBHF 250/20
927005907
Packing*10
P8AX25-xxx
BBHF 350/15
927006507
Packing*10
P8AX35-xxx
BBHF 500/20
927002207
Packing*10
P8AX50-xxx
BA HF 90/20
927100107
Packing*10
P8AX09-6G
BAHF 150/20
927100207
Packing*10
P8AX 25-6G
118
119
120
These components are made of two or three electrodes in an enclosure lled with a (non-radioactive) rare gas at a controlled pressure.
The enclosure is a ceramic tube with its ends closed off by metal caps
that also serve as electrodes.
Their main use is to protect telecommunications lines, but other uses
are possible.
Breakdown
voltage
Glow voltage
Line
electrode
Fail Safe
device
Arc voltage
Aluminia
insulation
Current
Operating regimes
Thermo-fusible
insulating disk
Rare gas
non-radioactive
emissive product
Ground
electrode
Operation
The gas discharge tube may be regarded as a sort of very fast switch
having conductance properties that change very rapidly, when breakdown occurs, from open-circuit to quasi-short circuit (arc voltage
about 20V). There are accordingly four operating domains in the behavior of a gas discharge tube:
Electrical characteristics
The main electrical characteristics dening a gas discharge tube are:
DC sparkover voltage (Volts)
Impulse sparkover voltage (Volts)
Discharge current capacity (kA)
Insulation resistance (Gohms)
Capacitance (pF).
DC sparkover voltage
This is the main characteristic dening the gas discharge tube.
It is the voltage at which breakdown will occur between the electrodes
when a slowly increasing voltage (dV/dt = 100 V/s) is applied to the
component; it depends on the electrode spacing, the pressure, and
the properties of the gas mixture and of the emissive substance.
Range of DC sparkover voltages available:
minimum 75V
average 230V
high voltage 500V
very high voltage 1000 to 3000V
The tolerance on the breakdown voltage is generally 20%. .
DC sparkover
voltage = 250 V
Dynamic area
1200
800
Impulse sparkover
voltage = 600 V
Static
area
400
100 V/s
0.1 V/s
1 kV/s
Discharge current
This depends on the properties of the gas, the volume, and the material and treatment of the electrodes. It is the major characteristic of
the GDT and the one that distinguishes it from other protection devices (Varistor, Zener diode, etc.): 5 to 20kA with an 8/20s impulse for
the standard components. This is the value the device can withstand
repeatedly (say for ten impulses) without destruction or alteration of
its basic specications.
Standards
CITEL proposes a full line of gas discharge tubes to meet most conguration needs and specications found on the market :
3-electrode configuration
GSG series
End of life
Gas discharge tubes are designed to withstand several impulses
without destruction or loss of the initial characteristics (typical impulse tests: 10 times 5 kA impulses of each polarity).
On the other hand, a sustained strong current (e.g. 10 A rms for 15
seconds, simulating the fall of a AC power line onto a telecommunication line) will put the device out of service denitively.
If a fail-safe end of life is desired (i.e. a short-circuit that will report
the fault to the user when the line fault is detected), gas discharge
tubes with the fail-safe feature (external short-circuit) should be chosen.
122
Selection guide
Insulation resistance
(100Vdc)
Capacitance
Holdover voltage
(R = 300 ohms in serie
R = 150 ohms; 100nF in parrallel)
AC discharge current
(50Hz)
BA
DC sparkover voltage
(100V/s)
Range
2-ELECTRODE
BA90
72-108 V
<640 V
>10G
<0.3 pF
>60 V
10 A
25 kA
10 kA
BA150
120-180V
<700 V
>10G
<0.3 pF
>80 V
10 A
25 kA
10 kA
BA230
184-276 V
<700 V
>10G
<0.3 pF
>80 V
10 A
25 kA
10 kA
BA300
240-360 V
<900 V
>10G
<0.3 pF
>80 V
10 A
25 kA
10 kA
BA350
280-420 V
<900 V
>10G
<0.3 pF
>80 V
10 A
25 kA
10 kA
BA550
440-660 V
<1200 V
>10G
<0.3 pF
>80 V
10 A
25 kA
10 kA
BB75
60-90 V
<640 V
>10G
<0.8 pF
>60 V
10 A
25 kA
10 kA
BB90
72-18 V
<640 V
>10G
<0.8 pF
>60 V
10 A
25 kA
10 kA
Mechanical
BA / BASQ
61 1
5
4.4
Options :
BB
BAS
BA4 / BASQ4
5 0.2
0.8
BB
BBS
6 0.3
BB150
120-180 V
<640 V
>10G
<0.8 pF
>75 V
10 A
25 kA
10 kA
BB230
184-276 V
<700 V
>10G
<0.8 pF
>80 V
10 A
25 kA
10 kA
BB350
280-420 V
<850 V
>10G
<0.8 pF
>80 V
10 A
25 kA
10 kA
BB500
400-600 V
<1200 V
>10G
<0.8 pF
>80 V
10 A
25 kA
10 kA
BH75
60-90 V
<640 V
>10G
<0.8 pF
>60 V
15 A
30 kA
15 kA
BH90
72-108 V
<640 V
>10G
<0.8 pF
>80 V
20 A
40 kA
20 kA
BH230
184-276 V
<700 V
>10G
<0.8 pF
>80 V
20 A
40 kA
20 kA
BH350
280-420 V
<850 V
>10G
<0.8 pF
>80 V
20 A
40 kA
20 kA
BH470
376-564 V
<1100 V
>10G
<0.8 pF
>80 V
20 A
40 kA
20 kA
BH500
400-600 V
<1200 V
>10G
<0.8 pF
>80 V
20 A
40 kA
20 kA
BH600
480-720 V
<1200 V
>10G
<0.8 pF
>80 V
20 A
40 kA
20 kA
BH800
640-690 V
<1400 V
>10G
<0.8 pF
>80 V
10 A
25 kA
10 kA
BH1400
1120-1680 V
<2000 V
>10G
<0.8 pF
>120 V
10 A
25 kA
10 kA
BH2500
2000-3000 V
<3800 V
>10G
<0.8 pF
>120 V
10 A
25 kA
10 kA
BH3500
2800-4200 V
<4600 V
>10G
<0.8 pF
>120 V
10 A
25 kA
10 kA
61 0.1
8 0.3
BH
Options :
BH
BHS
6 + 0.3 (75-500V)
6.8 + 0.3 (800-1500V)
8 + 0.3 (2000-3500V)
8 + 0.3
123
0.8
Options :
61 + 0.1
Selection guide
Insulation resistance
(100Vdc)
Capacitance
Holdover voltage
(R = 300 ohms in serie
R = 150 ohms; 100nF in parrallel)
AC discharge current
(50Hz)
BT
DC sparkover voltage
(100V/s)
Range
3-ELECTRODE
BT90
72-108 V
<640 V
>10G
<0.9 pF
>70 V
20 A
25 kA
20 kA
BT150
120-180 V
<640 V
>10G
<0.9 pF
>80 V
20 A
25 kA
Mechanical
11.1
max
20 kA
9.1 0.3
BTR
8.7 max
12.2 max
BTRC
17.7
max
8.25 0.15
5 0.5
BT230
184-276 V
<750 V
>10G
<0.9 pF
>80 V
20 A
25 kA
20 kA
BT350
280-420 V
<900 V
>10G
<0.9 pF
>80 V
20 A
25 kA
20 kA
BT500
400-600 V
<1100 V
>10G
<0.9 pF
>80 V
20 A
25 kA
20 kA
4.4 4.4
0.3 0.3
4.4 4.4
0.3 0.3
BT
BTS
9.1 0.3
47 5
9.1 0.3
0.8
8.25 0.15
E2
E1
18 0.5
M
BM
BM90
72-108 V
<640 V
>10G
<0.5 pF
>60 V
10 A
25 kA
10 kA
BMC
BM / BMSQ
7,50,5
BM150
120-180 V
<700 V
>10G
<0.5 pF
>80 V
10 A
25 kA
10 kA
50,15
BM230
184-276 V
<800 V
>10G
<0.5 pF
>80 V
10 A
25 kA
10 kA
BMS
7.8 max
7,50,5
7.8 max
475
BM4 / BMSQ4
7,50,5
BM350
280-420 V
<1000 V
>10G
<0.5 pF
>80 V
10 A
25 kA
10 kA
BM500
400-600 V
<1200 V
>10G
<0.5 pF
>80 V
10 A
25 kA
10 kA
E2
E1
7,50,5
1
50,15
185
Insulation resistance
(100Vdc)
BF
BG
DC sparkover voltage
(100V/s)
Range
BG600
450V
<1500 V
>10G
> 100 A
60 kA
100 kA
15 kA
BG800
650 V
<1500 V
>10G
> 100 A
60 kA
100 kA
15 kA
BG1000
850 V
<1800 V
>10G
> 100 A
60 kA
100 kA
15 kA
BG1300
1100 V
<2000V
>10G
> 100 A
60 kA
100 kA
15 kA
BF800
650-1000 V
<1500 V
>10G
> 100 a
80 kA
150 kA
50 kA
Mechanical
7.8 0.3
11.8 0.3
7.8 0.3
15.8 0.3
124
Selection guide
Insulation resistance
(100Vdc)
BF P100
DC sparkover voltage
(100V/s)
Range
BFP100-230
184-276 V
<900 V
>10G
80 kA
150 kA
50 kA
BFP100-250
200-300 V
<900 V
>10G
80 kA
150 kA
50 kA
BFP100-350
280-420 V
<1000 V
>10G
80 kA
150 kA
50 kA
BFP100-500
400-600 V
<1200 V
>10G
80 kA
150 kA
50 kA
BFP100-600
480-720 V
<1300 V
>10G
80 kA
150 kA
50 kA
Mechanical
BF P100
49.2 0.5
BF P100S
500 30
175 10
125
BFP100-750
600-900 V
<1500 V
>10G
80 kA
150 kA
50 kA
BFP100-800
640-940 V
<1500 V
>10G
80 kA
150 kA
50 kA
175 10
150 10
MISCELLANEOUS
OBSTRUCTIONS LIGHTS
126
SGP70
BF P100C
Characteristics
(in mm)
SGP
26
55
110
BF P100S
BF P100
SGP70
SGP40
Technology
Gas tube
Gas tube
Gas tube
DC sparkover
280-420 V
400 Vac
400 Vac
Impulse sparkover
(1 kV/s)
< 1000 V
< 1500 V
< 1500 V
Insulation resistance
> 1 GOhm
> 1 GOhm
> 1 GOhm
150 kA
70 kA
40 kA
50 kA
25 kA
10 kA
Dimensions
see drawing
see drawing
see drawing
Connection
wires (P100S)
wire terminal (P100C)
500 30
175 10
175 10
150 10
BF P100C
25 3
12 0.5
6.5
127
100 10
Outdoor application
Yes
Yes
Yes
Part number
consult us
690103
690102
Lightning counter
CF-01
CF-01
Installation
Characteristics
Mounting flange
(supplied)
CF-01
Description
0.3 kA
100 kA
999999
Display
LCD
Dimensions
65x50x45 mm
Weight
0.15 kg
Enclosure
Polycarbonate IP54
Power supply
internal by battery
Life expectancy
(before battery replacement)
> 10 years
Mounting
Compliance
NFC 17-106
128
Characteristics
Part number
13720
13721
13722
13723
13724
13725
Caracteristics
White
only
Red
only
Bi-color
White
only
Red
only
Bi-color
Power
supply
48 Vdc
48 Vdc
48 Vdc
120/230 Vac
120/230 Vac
120/230 Vac
Luminous intensity
Day : 20 000 Cd
Night : 2000 Cd
Day : 20 000 Cd
Night : 2000 Cd
Day : 20 000 Cd
Night : 2000 Cd
Day : 20 000 Cd
Night : 2000 Cd
Consumption max
< 100 W
< 30 W
< 100 W
< 100 W
< 30 W
< 100 W
Beam spread
Vertical : 3
Horizontal : 360
40
Surge protector
yes
Characteristics
OBSTA
Balise
230 Vac
Balise
24 Vdc
Part number
13812
13822
Power
supply
230 Vac
24 Vdc
< 150 W
< 140 W
Peak V.A
< 6000 VA
< 600 VA
Luminous intensity
Day : 20 000 Cd
Night : 2000 Cd
Color
Day : white
Night : red
Flashes/minute
20, 40 or 60
Beam spread
Vertical : 3
Horizontal : 360
129
Characteristics
NAVILITE
48 VDC
NAVILITE
24 VDC
NAVILITE
12 VDC
NAVILITE
240 VAC
Part
13900
13901
13902
13910 + 13900
Input voltage
48 VDC
24 VDC
12 VDC
240 V AC
Luminous intensity
> 10 candelas
> 10 candelas
> 10 candelas
> 10 candelas
Current drawn
125 mA
250 mA
500 mA
70 mA
Power consumption
6W
6W
6W
6W
Lifetime
Regulations
ICAO
ICAO
ICAO
ICAO
(*) : estimated lifetime (MTBF) given by LED manufacturer under certain conditions.
Options : Fixing bracket ; Box for one main and one back-up light with photocell and alarm indicator available in 48VDC
and 240 VAC; Outdoor cable; Solar station.
Please consult OBSTA catalogue for futher information.
Characteristics
OBSTA
HI STI
STI 48V
STI 24 V
STIF
Part number
13110
13200
13300
13410
Input voltage
110 V AC to
240 V AC
48 VDC
24 VDC
12 VDC
Surge protection
Yes
Yes
Yes
Yes
Alarm indicator
Yes
Yes
Yes
Yes
Luminous intensity
> 35 candlas
> 10 candelas
>10 candelas
> 10 candelas
Current drawn
370 up to 730 mA
250 mA
500 mA
500 mA
Power consumption
45 W
12 W
12 W
6W
Life time
Regulations
ICAO
ICAO
Characteristics
130
131
Head office
CITEL-2CP
2, rue Troyon
92316 Svres CEDEX
France
Tl. : +33 1 41 23 50 23
Fax : +33 1 41 23 50 09
e-mail : contact@citel2cp.com
Web : www.citel2cp.com
Factory
CITEL-2CP
3 impasse de la Blanchisserie
BP 56
51052 Reims CEDEX
France
Tl. : +33 3 26 85 74 00
Fax : +33 3 26 85 74 30
e-mail : citel@citelrs.com
Germany
CITEL Electronics GmbH
Alleestrasse 144, Tor 5
D-44793 Bochum
Allemagne
Tl. : +49 234 54 72 10
Fax : +49 234 54 72 199
e-mail : info@citel.de
Web : www.citel.de
China
Shanghai Citel Electronics
Co,Ltd
499 Kang Yi Road
Kang Qiao Industrial Zone
201315 Pudong, Shanghai
P.R. CHINA
Tl. : +86 21 58 12 25 25
Fax : +86 21 58 12 21 21
e-mail : shanghai@citel2cp.com
Web : www.citel.cn
Czech Republic
CITEL ELECTRONICS
Kundratka 17A
18000 Praha
Rpublique Tchque
Tl. : +420 284840-395
Fax : + 420 284840-195
e-mail : citel@citel.cz
Web : www.citel.cz
Russia
CITEL RUSSIA
Bolchaya Pochtovaya Str 26V/1
RU-105082 Moscow
Russie
Tl. : +7 495 669 32 70
e-mail : info@citel.ru
Web : www.citel.ru
USA
CITEL Inc.
India
CITEL INDIA