You are on page 1of 8

J

N
T
U
W
O
R
L
D
Code No: 57014 Set No. 1
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD
IV B.Tech. I Sem., I Mid-Term Examinations, August- 2012
INSTRUMENTATION
Objective Exam
Name: ______________________________ Hall Ticket No.
A

Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.

I. Choose the correct alternative:

1. The purpose of instruments is to [ ]
A) allow measurements to be made B) transmit the information
C) change the signal D) all of the above

2. Gearing, backlash, friction between moving parts and scale accuracies are generally known as [ ]
A) instrument error B) interference error C)calibration error D) interaction error

3. Purely mechanical instruments can not be used for dynamic measurements because they have [ ]
A) high inertia B) large time constant C)higher response time D) all of the above

4. The function of signal manipulating element, in a generalized measurement system is to [ ]
A) change the quantity under measurement to an analogous signal
B) change the magnitude of the input signal while retaining its identity
C)to perform non-linear operations like filtering , chopping and clipping and clamping
D) none of the above.

5. The source of emission of electrons in a CRT is [ ]
A) PN junction diode B) a barium and strontium oxide coated cathode
C) pre-accelerating anode D) post-accelerating anode

6. Vertical amplifier for a CRO is designed for [ ]
A) high gain B) broad band width
C) a constant gain times bandwidth product D) none of the above.

7. The deflection of an electron beam on a CRT screen is 10mm. suppose the pre-accelerating anode voltage is
halved and the potential between deflecting plates is doubled. The deflection of the electron beam will be:
[ ]
A) 80 mm B) 10 mm C) 20 mm D) 40 mm

8. Electronic voltmeters which use rectifiers employ negative feedback. This is done [ ]
A) to overcome nonlinearity of diodes B) to increase the over all gain
C) to improve stability D) none of the above

9. In an electronic ohmmeter, an OP-AMP is used as a [ ]
A) summer B) multiplier C) buffer amplifier D) integrator.

10. The resolution of a 3-1/2 digit display on 50V range is [ ]
A) 0.05 B)0.0005 C) 0.005 D) 0.5


Cont..2

www.jntuworld.com
www.jntuworld.com
www.jwjobs.net
J
N
T
U
W
O
R
L
D
Code No: 57014 :2: Set No. 1


II Fill in the Blanks:

11. ___________is the closeness with which an instrument reading approaches the true value of the quantity
being measured.

12. ________is the closeness of agreement among a number of consecutive measurements of the same variable
(value) under the same operating conditions, approaching in the same direction.

13. Given a 600 V voltmeter with accuracy 2% full scale. The limiting error when the instrument is used to
measure a voltage of 250V is _________

14. ___________ is the process of extracting the base band message from the carrier so that it maybe processed
and interpreted by the intended receiver.

15. The total bandwidth required for Amplitude Modulation is____________

16. The function of a _______ is to connect the test circuit to the oscilloscope without altering, loading or
otherwise disturbing the test circuit.

17. The shape of the Lissajous pattern depends on the ____________ relationship of the two sine waves.

18. _______ no. of electron beams are used to generate traces in Dual beam CRO.

19. The instrument used to measure the average value of the voltage is_______________

20. ______ no of thermo couples used in True R.M.S reading voltmeter.









-oOo-
www.jntuworld.com
www.jntuworld.com
www.jwjobs.net
J
N
T
U
W
O
R
L
D
Code No: 57014 Set No. 2
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD
IV B.Tech. I Sem., I Mid-Term Examinations, August- 2012
INSTRUMENTATION
Objective Exam
Name: ______________________________ Hall Ticket No.
A

Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.

I. Choose the correct alternative:

1. The function of signal manipulating element, in a generalized measurement system is to [ ]
A) change the quantity under measurement to an analogous signal
B) change the magnitude of the input signal while retaining its identity
C)to perform non-linear operations like filtering , chopping and clipping and clamping
D) none of the above.

2. The source of emission of electrons in a CRT is [ ]
A) PN junction diode B) a barium and strontium oxide coated cathode
C) pre-accelerating anode D) post-accelerating anode

3. Vertical amplifier for a CRO is designed for [ ]
A) high gain B) broad band width
C) a constant gain times bandwidth product D) none of the above.

4. The deflection of an electron beam on a CRT screen is 10mm. suppose the pre-accelerating anode voltage is
halved and the potential between deflecting plates is doubled. The deflection of the electron beam will be:
[ ]
A) 80 mm B) 10 mm C) 20 mm D) 40 mm

5. Electronic voltmeters which use rectifiers employ negative feedback. This is done [ ]
A) to overcome nonlinearity of diodes B) to increase the over all gain
C) to improve stability D) none of the above

6. In an electronic ohmmeter, an OP-AMP is used as a [ ]
A) summer B) multiplier C) buffer amplifier D) integrator.

7. The resolution of a 3-1/2 digit display on 50V range is [ ]
A) 0.05 B)0.0005 C) 0.005 D) 0.5

8. The purpose of instruments is to [ ]
A) allow measurements to be made B) transmit the information
C) change the signal D) all of the above

9. Gearing, backlash, friction between moving parts and scale accuracies are generally known as [ ]
A) instrument error B) interference error C)calibration error D) interaction error

10. Purely mechanical instruments can not be used for dynamic measurements because they have [ ]
A) high inertia B) large time constant C)higher response time D) all of the above


Cont..2

www.jntuworld.com
www.jntuworld.com
www.jwjobs.net
J
N
T
U
W
O
R
L
D
Code No: 57014 :2: Set No. 2


II Fill in the Blanks:

11. ___________ is the process of extracting the base band message from the carrier so that it maybe processed
and interpreted by the intended receiver.

12. The total bandwidth required for Amplitude Modulation is____________

13. The function of a _______ is to connect the test circuit to the oscilloscope without altering, loading or
otherwise disturbing the test circuit.

14. The shape of the Lissajous pattern depends on the ____________ relationship of the two sine waves.

15. _______ no. of electron beams are used to generate traces in Dual beam CRO.

16. The instrument used to measure the average value of the voltage is_______________

17. ______ no of thermo couples used in True R.M.S reading voltmeter.

18. ___________is the closeness with which an instrument reading approaches the true value of the quantity
being measured.

19. ________is the closeness of agreement among a number of consecutive measurements of the same variable
(value) under the same operating conditions, approaching in the same direction.

20. Given a 600 V voltmeter with accuracy 2% full scale. The limiting error when the instrument is used to
measure a voltage of 250V is _________









-oOo-
www.jntuworld.com
www.jntuworld.com
www.jwjobs.net
J
N
T
U
W
O
R
L
D
Code No: 57014 Set No. 3
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD
IV B.Tech. I Sem., I Mid-Term Examinations, August- 2012
INSTRUMENTATION
Objective Exam
Name: ______________________________ Hall Ticket No.
A

Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.

I. Choose the correct alternative:

1. Vertical amplifier for a CRO is designed for [ ]
A) high gain B) broad band width
C) a constant gain times bandwidth product D) none of the above.

2. The deflection of an electron beam on a CRT screen is 10mm. suppose the pre-accelerating anode voltage is
halved and the potential between deflecting plates is doubled. The deflection of the electron beam will be:
[ ]
A) 80 mm B) 10 mm C) 20 mm D) 40 mm

3. Electronic voltmeters which use rectifiers employ negative feedback. This is done [ ]
A) to overcome nonlinearity of diodes B) to increase the over all gain
C) to improve stability D) none of the above

4. In an electronic ohmmeter, an OP-AMP is used as a [ ]
A) summer B) multiplier C) buffer amplifier D) integrator.

5. The resolution of a 3-1/2 digit display on 50V range is [ ]
A) 0.05 B)0.0005 C) 0.005 D) 0.5

6. The purpose of instruments is to [ ]
A) allow measurements to be made B) transmit the information
C) change the signal D) all of the above

7. Gearing, backlash, friction between moving parts and scale accuracies are generally known as [ ]
A) instrument error B) interference error C)calibration error D) interaction error

8. Purely mechanical instruments can not be used for dynamic measurements because they have [ ]
A) high inertia B) large time constant C)higher response time D) all of the above

9. The function of signal manipulating element, in a generalized measurement system is to [ ]
A) change the quantity under measurement to an analogous signal
B) change the magnitude of the input signal while retaining its identity
C) to perform non-linear operations like filtering , chopping and clipping and clamping
D) none of the above.

10. The source of emission of electrons in a CRT is [ ]
A) PN junction diode B) a barium and strontium oxide coated cathode
C) pre-accelerating anode D) post-accelerating anode


Cont..2

www.jntuworld.com
www.jntuworld.com
www.jwjobs.net
J
N
T
U
W
O
R
L
D
Code No: 57014 :2: Set No. 3


II Fill in the Blanks:

11. The function of a _______ is to connect the test circuit to the oscilloscope without altering, loading or
otherwise disturbing the test circuit.

12. The shape of the Lissajous pattern depends on the ____________ relationship of the two sine waves.

13. _______ no. of electron beams are used to generate traces in Dual beam CRO.

14. The instrument used to measure the average value of the voltage is_______________

15. ______ no of thermo couples used in True R.M.S reading voltmeter.

16. ___________is the closeness with which an instrument reading approaches the true value of the quantity
being measured.

17. ________is the closeness of agreement among a number of consecutive measurements of the same variable
(value) under the same operating conditions, approaching in the same direction.

18. Given a 600 V voltmeter with accuracy 2% full scale. The limiting error when the instrument is used to
measure a voltage of 250V is _________

19. ___________ is the process of extracting the base band message from the carrier so that it maybe processed
and interpreted by the intended receiver

20. The total bandwidth required for Amplitude Modulation is____________







-oOo-
www.jntuworld.com
www.jntuworld.com
www.jwjobs.net
J
N
T
U
W
O
R
L
D
Code No: 57014 Set No. 4
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD
IV B.Tech. I Sem., I Mid-Term Examinations, August- 2012
INSTRUMENTATION
Objective Exam
Name: ______________________________ Hall Ticket No.
A

Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.

I. Choose the correct alternative:

1. Electronic voltmeters which use rectifiers employ negative feedback. This is done [ ]
A) to overcome nonlinearity of diodes B) to increase the over all gain
C) to improve stability D) none of the above

2. In an electronic ohmmeter, an OP-AMP is used as a [ ]
A) summer B) multiplier C) buffer amplifier D) integrator.

3. The resolution of a 3-1/2 digit display on 50V range is [ ]
A) 0.05 B)0.0005 C) 0.005 D) 0.5

4. The purpose of instruments is to [ ]
A) allow measurements to be made B) transmit the information
C) change the signal D) all of the above

5. Gearing, backlash, friction between moving parts and scale accuracies are generally known as [ ]
A) instrument error B) interference error C)calibration error D) interaction error

6. Purely mechanical instruments can not be used for dynamic measurements because they have [ ]
A) high inertia B) large time constant C)higher response time D) all of the above

7. The function of signal manipulating element, in a generalized measurement system is to [ ]
A) change the quantity under measurement to an analogous signal
B) change the magnitude of the input signal while retaining its identity
C) to perform non-linear operations like filtering , chopping and clipping and clamping
D) none of the above.

8. The source of emission of electrons in a CRT is [ ]
A) PN junction diode B) a barium and strontium oxide coated cathode
C) pre-accelerating anode D) post-accelerating anode

9. Vertical amplifier for a CRO is designed for [ ]
A) high gain B) broad band width
C) a constant gain times bandwidth product D) none of the above.

10. The deflection of an electron beam on a CRT screen is 10mm. suppose the pre-accelerating anode voltage is
halved and the potential between deflecting plates is doubled. The deflection of the electron beam will be:
[ ]
A) 80 mm B) 10 mm C) 20 mm D) 40 mm



Cont..2
www.jntuworld.com
www.jntuworld.com
www.jwjobs.net
J
N
T
U
W
O
R
L
D

Code No: 57014 :2: Set No. 4


II Fill in the Blanks:

11. _______ no. of electron beams are used to generate traces in Dual beam CRO.

12. The instrument used to measure the average value of the voltage is_______________

13. ______ no of thermo couples used in True R.M.S reading voltmeter.

14. ___________is the closeness with which an instrument reading approaches the true value of the quantity
being measured.

15. ________is the closeness of agreement among a number of consecutive measurements of the same variable
(value) under the same operating conditions, approaching in the same direction.

16. Given a 600 V voltmeter with accuracy 2% full scale. The limiting error when the instrument is used to
measure a voltage of 250V is _________

17. ___________ is the process of extracting the base band message from the carrier so that it maybe processed
and interpreted by the intended receiver.

18. The total bandwidth required for Amplitude Modulation is____________

19. The function of a _______ is to connect the test circuit to the oscilloscope without altering, loading or
otherwise disturbing the test circuit.

20. The shape of the Lissajous pattern depends on the ____________ relationship of the two sine waves.








-oOo-

www.jntuworld.com
www.jntuworld.com
www.jwjobs.net