Anexo 00 - Tabelas Auxiliares

In, Inf, e I2 de disjuntores


In
2
4
6
8
10
12
16
20
25
30
40
50
63
80
100
125
160
200
250
315
400
500
630
800
1000
1250

Inf
6.3
8.4
10.5
12.6
16.8
21
26.3
33
42
53
66
84
105
131
168
210
263
331
420
525
662
840
1050
1313

In, Inf, e I2 de fusveis

I2
8.1
10.8
13.5
16.2
21.6
27
33.8
39
54
68
85
108
135
169
216
270
338
425
540
675
851
1080
1350
1688

In
2
4
6
8
10
12
16
20
25
30
32
40
50
63
80
100
125
160
200
250
315
400
500
630
800
1000
1250

Inf
3
6
9
12
15
17
22
28
35
39
42
52
65
82
104
130
150
192
240
300
378
480
650
756
960
1200
1500

Designao Cablagens
VV (H05VV-U, H05VV-R)
VAV
LSVV
XV
LSVV

I2
4
8
11
15
19
21
28
35
44
48
51
64
80
101
128
160
200
256
320
400
504
640
800
1008
1280
1600
2000

Resistncia e Inductncia lineares


dos cabos

Resistncia e Inductncia lineares


dos cabos

Cobre

Aluminio

S (mm)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500

Tipos de Arranque
Directo
Y-
VEV
-----

Tenses de Funcionamento U (V)


230
400

Disposio das Cablagens

r (20C)
(/km)
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.047
0.0366

l (20C)
(mH/km)
0
0
0
0
0.29
0.26
0.25
0.24
0.24
0.23
0.23
0.22
0.22
0.22
0.22
0.22
0.22
0.22

S (mm)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
380

Esteira
Calha
Caleira
vista
Enterrado
Embebido
Amovvel
-----

Cabo VV

Cabos Enterrados em
Grupos K1
l (20C)
(mH/km)
0
0
0
0
0
0.25
0.25
0.24
0.24
0.23
0.23
0.22
0.22
0.22
0.22
0.22

Coeficiente de
Termoresistividade
(C-1)
Cobre
Alumnio

Cabo X / XV / XAV
Correntes Admissivis para Cabos Cobre ao Ar

r (20C)
(/km)
0
0
0
0
0
1.41
1.2
0.858
0.641
0.443
0.32
0.253
0.206
0.164
0.125
0.08

Factores de Correco

0.0039
0.0040

Cabo LX / LXV / LXAV

Correntes Admissivis para Cabos Cobre ao ar

Correntes Admissivis para Cabos Alumnio ao Ar

S (mm)

1 condutores

2 condutores

3 condutores

S (mm)

1 condutores

3 a 4 condutores

S (mm)

1 condutores

3 a 4 condutores

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500

27
36
48
60
85
110
145
180
210
275
330
390
440
505
595
685
820
935

22
30
40
50
70
95
125
150
180
225
270
305
350
390
455
510
610
---

18.5
22
34
43
60
80
101
126
153
196
238
276
310
355
410
470
560
---

16
25
35
50
70
95
120
150
185

------285
370
450
530
610
725
850

105
135
170
205
260
320
370
435
490
585

16
25
35
50
70
95
120
150
185
240

------215
280
345
405
460
540
645

75
105
125
160
195
240
280
325
380
445

N Cabos

K1

1
2
3
4
5
6
8
10

1.00
0.90
0.80
0.75
0.70
0.65
0.62
0.60

Sistemas Trifsicos
com Cabos
Monopolares
enterrados em
Conjunto K2

N Cabos

k2

1
2
3

1.00
0.90
0.80

Temp. (C)

k3

5
10
15
25
30
35
40

1.15
1.10
1.05
0.94
0.88
0.82
0.75

Cabos Instalados ao Ar
em Grupos K4

Distncia
Entre Cabos

Numero de Cabos
At 3

4a6

Inferior ao
Dimetro

0.8

0.75

Inferior ao
Dimetro

0.8

0.75

Anexo 00 - Tabelas Auxiliares (Continuao 1)

Cabo VAV

Cabo X / XV / XAV
Correntes Admissivis para Cabos Cobre Enterrados

Cabo LX / LXV / LXAV

Correntes Admissivis para Cabos Cobre Enterrado

Correntes Admissivis para Cabos Alumnio Enterrado

S (mm)

1 condutores

2 condutores

3 condutores

S (mm)

1 condutores

3 a 4 condutores

S (mm)

1 condutores

3 a 4 condutores

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500

34
45
60
75
105
135
180
225
260
345
410
485
550
630
740
855
1015
1170

30
40
50
65
90
120
155
185
220
280
335
380
435
490
570
640
760
---

25
35
45
60
80
110
135
165
190
245
295
340
390
445
515
590
700
---

16
25
35
50
70
95
120
150
185
240

------330
410
480
550
625
700
815

120
160
195
235
290
340
395
445
505
590

16
25
35
50
70
95
120
150
185
240

------255
310
375
425
480
535
625

95
120
150
185
220
270
300
340
390
450

Cabo LSVV

Cabo LSVAV
Correntes Admissivis para Cabos Alumnio ao Ar

Correntes Admissivis para Cabos Alumnio Enterrados

S (mm)

1 condutores

2 condutores

3 condutores

S (mm)

1 condutores

2 condutores

3 condutores

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500

----38
48
70
90
115
145
170
220
265
310
350
405
475
550
655
750

----32
40
55
75
100
120
145
180
215
245
280
310
365
410
490
---

----29
38
50
70
90
105
120
155
190
215
250
285
330
375
450
---

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500

----48
60
85
110
145
185
210
275
330
390
440
505
590
685
810
935

----40
50
70
95
125
150
175
225
270
305
350
390
455
510
610
---

----35
48
65
90
110
130
150
195
235
270
310
355
410
470
580
---

Anexo 00 - Tabelas Auxiliares (Continuao 2)

Seco dos condutores de Neutro e de Proteco

Seco de
Condutores de Fase
(mm)

Seco Condutor
Neutro e Prot.
(mm)

S (mm)

Seco Condutor Neutro e


Prot. (mm)

1.5
2.5
4
6
10
16
25
35
50
70
95

1.5
2.5
4
6
10
10
16
16
25
35
50

120
150
185
240
300
400
500
630
800
1000
---

70
70
95
120
150
185
240
300
400
500
---

3/3,6 kV

6/7,2 kV

Potncia Nominal do
Transformador
50
75
100
125
160
200
250
315
400
500
630
800
1000

Ucc (%)

IN(min.) A IN(mx.) A
20
50
30
75
40
100
50
125
63
160
75
200
100
160
125
200
125
200
160
250
200
250
250
315
-----

IN(min.) A
10
16
20
25
30
40
50
63
75
100
125
160
160

Notas: As correntes admissveis indicadas, referem-se seguintes condies de instalao:


~ Temperatura ambiente: 20C
~ Temperatura do Solo: 20C
~ Resistncia Trmica do Solo: 70C
~ Profundidade de enterramento: 0,5 a 0,7 mts
~ Temperatura da alma condutora: 70C para PVC, 90C para PRC
Constante K

Isolamento

Alumnio

Cobre

PVC
PRC
n

74
87
104

115
135
159

Transformador (lado Mdia Tenso)


10/12 kV
20/24 kV
30/36 kV
Fusveis de Mdia Tenso de A-P.C.
IN(mx.) A IN(min.) A IN(mx.) A IN(min.) A IN(mx.) A IN(min.) A IN(mx.) A
25
6
16
6
4
6
3
40
10
25
6
5
10
4
50
16
30
10
6
20
6
63
16
40
10
10
20
6
100
20
50
16
10
25
10
100
25
63
20
16
30
10
100
30
50
20
16
25
10
100
40
75
25
20
40
16
125
50
100
30
25
40
16
160
63
100
40
30
50
20
200
75
125
50
40
63
25
200
100
160
63
50
100
30
250
125
200
63
63
125
40

Coeficientes de utilizao em instalaes industriais

Utilizao / Receptores
Instalaes de iluminao
Instalaes de aquecimento
Motores
Instalaes de Tomadas
(*) Na dvida, aconselha-se a considerao do coeficiente 1.

Coeficiente de simultaneidade em quadors elctricos industriais (UTE - 410)

Coeficientes de utilizao (Ku)

N de Circuitos

Coeficientes de simultaneidade (Ku)

1
1
0,3 - 0,75
Varivel consoante a utilizao (*)

2 -- 3
4 -- 5
6 -- 9
10 e mais

0.9
0.8
0.7
0.6

Anexo 00 - Tabelas Auxiliares (Continuao 3)

Coeficiente de simultaneidade em instalaes de Utilizao de enrgia elctrica (NFC 15 - 100)

Tipo de utilizao

Coeficiente de simultaneidade usuais para receptores

Coeficientes de simultaneidade (Ks)

Tipo de utilizao

Iluminao
1
Ar Condicionado
1
Aquecimento elctrico (ambiente e guas sanitrias)
1 (*1)
Tomadas (N - n de tomadas por circuito)
0,1 + 0,9/N
Aparelhos de cozinha
0.7
Ascensores e monta cargas (*2)
Motor mais potente
1
Motor seguinte
0.75
Outros motores
0.6
(*1) Se for de considerar potncia interruptvel podero ser considerados outros valores tendo em conta o regime de
explorao (nmero de horas desligadas).
(*2) A corrente a considerar dever incluir a influncai do arranque (corrente nominal do motor + 1/3 da corrente de arranque).
Este tipo de coeficiente aplicado em geral s canalizaes alimentando diversos motores.

Barras rectangulares na posio horizontal ("ao baixo")


Barras no pintadas
Cobre

Barras rectangulares na posio horizontal ("ao baixo")


Barras no pintadas
Alumnio

Troos a evitar
axb (mm) s (mm 2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

12x2
15x2
15x3
20x2
20x3
20x5
25x3
25x5
30x3
30x5
40x3
40x5
40x10
50x5
50x10
60x5
60x10
80x5
80x10
100x5
100x10

24
30
45
40
60
100
75
125
90
150
120
200
400
250
500
300
600
400
800
500
1000

W (cm 3)

I (cm 4)

p (kgf/m)

Imx (A)

0.048
0.075
0.113
0.133
0.200
0.333
0.313
0.521
0.450
0.750
0.800
1.330
2.670
2.080
4.170
3.000
6.000
5.330
10.700
8.330
16.700

0.0288
0.0563
0.0844
0.1330
0.2000
0.3330
0.3910
0.6510
0.6750
1.1300
1.6000
2.6700
5.3300
5.2100
10.4000
9.0000
18.0000
21.3000
42.7000
41.7000
83.3000

0.209
0.262
0.396
0.351
0.529
0.882
0.663
1.110
0.796
1.330
1.060
1.770
3.550
2.220
4.440
2.660
5.330
3.550
7.110
4.440
8.880

110
140
170
185
220
295
270
350
315
400
420
520
760
630
920
760
1060
970
1380
1200
1700

Coeficientes de simultaneidade (Ks)

Iluminao
Grandes cozinhas
Tomadas
10/16 A
20/32 A
Motores
Aquecimento, frio e ventilao
Aparelhos de levao
(*1) O valor de 0,25 usado vulgarmente para 8n pontos de utilizao porircuito.

Troos a evitar

45-55 Hz 90-110 Hz
92-102
103-115
103-115
119-132
119-132
119-132
133-148
133-148
146-162
146-162
168-186
168-186
168-186
188-218
188-218
206-229
206-229
238-261
238-264
265-295
265-295

65-72
73-81
73-81
83-93
83-93
83-93
94-104
94-104
103-114
103-114
119-132
119-132
119-132
133-148
133-148
146-161
146-161
168-186
168-186
188-208
188-208

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

axb (mm)

s (mm 2)

W (cm 3)

I (cm 4)

p (kgf/m)

Imx (A)

12x2
15x2
15x3
20x2
20x3
20x5
25x3
25x5
30x3
30x5
40x3
40x5
40x10
50x5
50x10
60x5
60x10
80x5
80x10
100x5
100x10

24
30
45
40
60
100
75
125
90
150
120
200
400
250
500
300
600
400
800
500
1000

0.048
0.075
0.113
0.133
0.200
0.333
0.313
0.521
0.450
0.750
0.800
1.330
2.670
2.080
4.170
3.000
6.000
5.330
10.700
8.330
16.700

0.0288
0.0563
0.0844
0.1330
0.2000
0.3330
0.3910
0.6510
0.6750
1.1300
1.6000
2.6700
5.3300
5.2100
10.4000
9.0000
18.0000
21.3000
42.7000
41.7000
83.3000

0.063
0.080
0.120
0.107
0.161
0.268
0.201
0.335
0.242
0.403
0.323
0.538
1.080
0.673
1.350
0.808
1.620
1.080
2.160
1.350
2.700

80
95
115
120
145
195
180
230
205
270
280
350
515
425
625
500
730
680
940
820
1150

45-55 Hz

90-110 Hz

107-120
120-135
120-135
139-155
139-155
139-155
155-174
155-174
170-190
170-190
196-218
196-218
196-218
219-256
219-256
241-268
241-268
278-309
278-309
310-346
310-346

76-85
85-95
85-95
97-109
97-109
97-109
109-122
109-122
120-134
120-134
139-155
139-155
139-155
155-174
155-174
170-189
170-189
196-218
196-218
219-244
219-244

0,7 - 1
0,8 - 1
0,25 - 0,5 (*1)
0,5 - 1
0,7 - 1
1
0,7 - 1

Anexo 00 - Tabelas Auxiliares (Continuao 4)


Barras rectangulares na posio vertical ("ao alto" ou em "cutelo")
Barras no pintadas
Cobre

Barras rectangulares na posio vertical ("ao alto" ou em "cutelo")


Barras no pintadas
Alumnio

Troos a evitar
axb (mm) s (mm 2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

12x2
15x2
15x3
20x2
20x3
20x5
25x3
25x5
30x3
30x5
40x3
40x5
40x10
50x5
50x10
60x5
60x10
80x5
80x10
100x5
100x10

24
30
45
40
60
100
75
125
90
150
120
200
400
250
500
300
600
400
800
500
1000

W (cm 3)

I (cm 4)

p (kgf/m)

Imx (A)

0.008
0.010
0.023
0.013
0.030
0.083
0.038
0.104
0.045
0.125
0.060
0.167
0.667
0.208
0.833
0.250
1.000
0.333
1.330
0.417
1.670

0.0008
0.0010
0.0034
0.00133
0.0045
0.0208
0.0056
0.0260
0.0068
0.0313
0.0090
0.0417
0.3330
0.0521
0.4170
0.0625
0.5000
0.0833
0.6670
0.1040
0.8330

0.209
0.262
0.396
0.351
0.529
0.882
0.663
1.110
0.796
1.330
1.060
1.770
3.550
2.220
4.440
2.660
5.330
3.550
7.110
4.440
8.880

110
140
170
185
220
295
270
350
315
400
420
520
760
630
920
760
1060
970
1380
1200
1700

Troos a evitar

45-55 Hz 90-110 Hz
37-42
37-42
46-51
37-42
46-51
60-66
46-51
60-66
46-51
60-66
46-51
60-66
84-93
60-66
84-93
60-66
84-83
60-66
84-93
60-66
84-93

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

26-30
26-30
32-36
26-30
32-36
42-47
32-36
42-47
32-36
42-47
32-36
42-47
59-66
42-47
59-66
42-47
59-66
42-47
59-66
42-47
59-66

axb (mm)

s (mm 2)

W (cm 3)

I (cm 4)

p (kgf/m)

Imx (A)

12x2
15x2
15x3
20x2
20x3
20x5
25x3
25x5
30x3
30x5
40x3
40x5
40x10
50x5
50x10
60x5
60x10
80x5
80x10
100x5
100x10

24
30
45
40
60
100
75
125
90
150
120
200
400
250
500
300
600
400
800
500
1000

0.008
0.010
0.023
0.013
0.030
0.083
0.038
0.104
0.045
0.125
0.060
0.167
0.667
0.208
0.833
0.250
1.000
0.333
1.330
0.417
1.670

0.0008
0.0010
0.0034
0.00133
0.0045
0.0208
0.0056
0.0260
0.0068
0.0313
0.0090
0.0417
0.3330
0.0521
0.4170
0.0625
0.5000
0.0833
0.6670
0.1040
0.8330

0.063
0.080
0.120
0.107
0.161
0.268
0.201
0.335
0.242
0.403
0.323
0.538
1.080
0.673
1.350
0.808
1.620
1.080
2.160
1.350
2.700

80
95
115
120
145
195
180
230
205
270
280
350
515
425
625
500
730
680
940
820
1150

Barras rectangulares na posio vertical ("ao alto" ou em "cutelo")


Barras pintadas
Cobre

axb (mm) s (mm 2)


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

12x2
15x2
15x3
20x2
20x3
20x5
25x3
25x5
30x3
30x5
40x3
40x5
40x10
50x5
50x10
60x5
60x10
80x5
80x10
100x5
100x10
120x10
160x10
200x10

24
30
45
40
60
100
75
125
90
150
120
200
400
250
500
300
600
400
800
500
1000
1200
1600
2000

p (kgf/m)

Imx (A)

0.21
0.27
0.40
0.36
0.53
0.89
0.67
1.11
0.80
1.34
1.07
1.78
3.56
2.23
4.45
2.67
5.34
3.56
7.12
4.45
8.90
10.68
14.24
17.80

125
155
185
205
245
325
300
385
350
450
460
600
835
700
1025
825
1200
1060
1540
1310
1880
2200
2880
-----

45-55 Hz

90-110 Hz

43-49
43-49
53-60
43-49
53-60
70-78
53-60
70-78
53-60
70-78
53-60
70-78
98-109
70-78
98-109
70-78
98-109
70-78
98-109
70-78
98-109

31-35
31-35
37-43
31-35
37-43
49-55
37-43
49-55
37-43
49-55
37-43
49-55
69-78
49-55
69-78
49-55
49-78
49-55
69-78
49-55
69-78

Barras em varetas circulares


Barras no pintadas
Cobre

1
2
3
4
5
6
7

(mm)

s (mm 2)

W (cm 3)

I (cm 4)

p (kgf/m)

Imx (A)

8
10
13
16
20
25
30

50.26
78.54
132.73
201.06
314.16
490.87
706.86

0.0503
0.0982
0.2157
0.4021
0.7854
1.5340
2.6507

0.0201
0.0491
0.1402
0.32170
0.7854
1.9175
3.9761

0.447
0.699
1.180
1.789
2.796
4.350
6.291

150
210
310
410
540
730
900

Troos a evitar
45-55 Hz
69-77
77-86
89-98
98-109
110-122
121-134
135-149

90-110 Hz
49-55
55-61
63-70
70-77
77-86
85-95
95-106

Barras em varetas circulares


Barras no pintadas
Alumnio

1
2
3
4
5
6
7

(mm)

s (mm 2)

W (cm 3)

I (cm 4)

p (kgf/m)

Imx (A)

8
10
13
16
20
25
30

50.26
78.54
132.73
201.06
314.16
490.87
706.86

0.0503
0.0982
0.2157
0.4021
0.7854
1.5340
2.6507

0.0201
0.0491
0.1402
0.32170
0.7854
1.9175
3.9761

0.136
0.212
0.358
0.543
0.848
1.320
1.909

124
167
242
314
424
569
693

Troos a evitar
45-55 Hz
80-90
90-100
104-115
115-128
129-143
143-159
157-174

90-110 Hz
57-64
64-71
73-82
82-90
90-100
101-113
111-123

Anexo 00 - Tabelas Auxiliares (Continuao 5)


Tabelas para o dimensionamento da ventilao do PT

Potncia do Transformador S (kVA)

U(kV)

630
800
1000

Caractersticas da zona abastecida


Residencial
Comercial/Servios
Mista (Residencial/Comercial/Servios)
Industrial
Veraneio (Praias/Termas)

Tipo de cabine
Baixa
Alta

15/0,4

Banho de leo mineral


p0 (kW)

pcu (kW)

C ()

1.30

6.50

16100.00

1.55

8.20

18700.00

1.85

10.00

21900.00

(C)
30
30
30
30
30

C
0.75
0.80
0.75
0.80
0.90

Inverno
C
0.90
0.90
0.90
0.90
0.60

Vero
(C)
14
12
13
12
12

H (m)
Up 15kV
3.30
8.50

15kV Up 30kV
3.90
8.50

Anexo 01

Piso

P
I
S
O
0

P
I
S
O
1

Calculo Preliminar da Potencia Eletrica Requerida em Iluminacao Interior


s
Tipo de Lmpada
S=A*Em*
2
Em
[lux]
Local a Iluminar
[VA/m^2
rea [m ]
1
Eltrica
S [VA]
(* )
*lux]
Instalaes Sanitrias [H]
Instalaes Sanitrias [S]
Instalaes Sanitrias
Gabinete 1
Secretaria Receo
Refeitrio Convvio
Informtica
Serralharia
Ar Comprimido e Bombagem
Carga/Descarga
Escadas/ Corredor
Nave Fabril
Nave Fabril (limpeza/noite)
Escadas
Instalaes Sanitrias
Gabinete Gerncia
Sala de Reunies
Gabinete 2
Sala de Desenho
Instalaes Sanitrias
Hall
Corredor + Escadas
Plataforma

12
12
6
38
22
27
7
12
33
-20
407
407
20
10
17
23
25
54
6
23
25
88

200
200
200
400
300
200
500
300
200
-150
300
150
150
200
400
500
400
750
200
100
100
300

*1 : Valores retirados da Norma europeia EN 12464-1

Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
-Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente
Fluorescente

0.048
0.048
0.048
0.048
0.048
0.048
0.048
0.032
0.048
-0.048
0.032
0.032
0.048
0.048
0.048
0.048
0.048
0.048
0.048
0.048
0.048
0.032

115.2
115.2
57.6
729.6
316.8
259.2
168
115.2
316.8
-144
3907.2
1953.6
144
96
326.4
552
480
1944
57.6
110.4
120
844.8

Avaliao da Potncia Prevista


Piso

P
I
S
O
0

P
I
S
O
1

Local

rea [m2]

S [VA]

Instalaes Sanitrias [H]


Instalaes Sanitrias [S]
Instalaes Sanitrias
Gabinete 1
Secretaria Receo
Refeitrio Convvio
Informtica
Serralharia
Ar Comprimido e Bombagem
Carga/Descarga
Escadas
Nave Fabril
Nave Fabril (limpeza/noite)
Escadas
Instalaes Sanitrias
Gabinete Gerncia
Sala de Reunies
Gabinete 2
Sala de Desenho
Instalaes Sanitrias
Hall
Corredor + Escadas
Plataforma

12
12
6
38
22
27
7
12
33
-20
407
407
20
10
17
23
25
54
6
23
25
88

115.2
115.2
57.6
729.6
316.8
259.2
168
115.2
316.8
-144
3907.2
1953.6
144
96
326.4
552
480
1944
57.6
110.4
120
844.8

Total [kVA]: 12.8736


Total Previsto [kVA]:

12.87

Climatizao
[VA] (*1)

Tomadas
Monofsicas [kVA]

3040
1760

3.68
3.68
3.68
3.68
3.68
3.68
3.68
3.68

560

3.68
3.68
3.68
3.68
3.68
3.68
3.68
3.68
3.68

1360
1840
2000
4320

14.88

31.28

14.88

15.64

*1: para a potncia de climatizao considerou-se um valor de referncia [VA/m2


Fator de Simultaneidade para Tomadas Monofsicas a considerar:
Fator de Simultaneidade para Tomadas Trifsicas a considerar:

Avaliao da Potncia Prevista para Iluminao Exterior


Potncia Luminria [W]
N Luminrias
Iluminao Exterior

Perdas no Balastro
Fator de Potncia

16

1.07
1

70

Anexo 02

Tomadas
Trifsicas
[kVA]

11.09

11.09
22.17
4.43
80
0.5
0.2

S [kVA]
1.20

Anexo 03
N.

Identificao
1
2
3
4
5
6
7
8
9
10
11
12

Co-Extrusora 1
Co-Extrusora 2
Extrusora 1
Extrusora 2
Extrusora 3
Mquina de corte 1
Mquina de corte 2
Compressor 1
Compressor 2
Bomba de gua
Bomba de aspirao
Monta Cargas

Aliment.
[V]
kW
400

Potncia
kVA

Rend.

FP

65.0

0.80

400

65.0

0.80

400

45.0

0.85

400

45.0

0.85

400

35.0

0.80

400

6.3

0.85

231

3.0

0.82

400

18.0

18.4

0.91

0.98

400

11.0

11.2

0.88

0.98

400
400
400

1.8
10.5
5.0

1.9
10.7
5.9

0.81
0.83
0.70

0.96
0.98
0.85

Total

312.3

Total Previsto (*1)

218.62

(*1) Assumindo um fator de simultaneidade de 0,7

nexo 03

Potncias

Valor [kVA]

Potncia Mquinas
Potncia p/ Iluminao Interior

312.3
12.8736

Potncia Climatizao

14.88

Potncia Tomadas

19.31

Potncia p/ Iluminao Exterior

1.20

Somatrio

360.58

Total Previsto

576.93

Transformador a pedir

630 kVA

Fator de Simultaneidade
Fator Evoluo das Cargas

0.8
2

Anexo 04
Piso

P
I
S
O
0

Local a Iluminar

Comp.

Larg.

Pd

Em [lux]

Designao da
Luminria

Instalaes Sanitrias [H]


Instalaes Sanitrias [S]

3.4
3.4

Instalaes Sanitrias
Gabinete 1

2.35
7.65
6.9
2.45

3.35
3.35
2.3
4.9
2.05
2.1

3
3
3
3
3
3

200
200
200
400
300
300

GSP 01 138
GSP 01 138
GSP 01 138
ATB 01 180
ATB 01 180
ATB 01 154

Refeitrio Convvio

5.49

4.9

200

ATB 01 154

Informtica
Serralharia
Ar Comprimido e Bombagem
Carga/Descarga
Nave Fabril (Limpeza)

2.85
5.6
8
-23.8
11.5
35.13
27.9
6.85
3.25
4.9
4.9
5.09
11.9
2.75
4.4
27.9
6.85
11.5

2.4
2.04
4
-12.82
7.64
12.9
1.8
2.93
1.8
3.4
4.5
4.9
4.9
1.8
4.1
1.8
2.93
7.64

3
3
3
-7
3
7
3
3
2.8
2.8
2.8
2.8
2.8
2.8
7
2.8
2.8
3.6

500
300
200
-150
300
300
100
100
200
400
500
400
750
200
100
100
100
300

ATB 01 254
NPAS 07 236
NPA 07 236
-MHPX 04 280
NPAS 07 236
IDL 01 40I
ATB 01 149
ATB 01 135
GSP 01 138
ATB 01 180
ATB 01 254
ATB 01 239
ATB 01 254
GSP 01 138
ATB 01 280
ATB 01 149
ATB 01 135
NPAS 07 258

Local a
Iluminar

Designao
Luminria

Secretaria Receo

Nave Fabril
Corredor + Escadas

P
I
S
O
1

I.S. Gab. Ger.


Gabinete Gerncia
Sala de Reunies
Gabinete 2
Sala de Desenho
Instalaes Sanitrias
Hall
Corredor + Escadas
Plataforma

Exterior

Nota:

Indelague XSPVS 70W

No WinElux assumimos que o fator de manuteno de 0,75 e a altura de

Piso 0 Serv. Adm


Piso 1
Nave Fabril

Anexo 04
Tipo de Lmpada
Eltrica

Nmero
Tipo Balastro Lmpadas por
luminria

Quantidade
Luminrias

Potncia
Lmpada
[W]

Potncia
Total
Luminria
[W]

fluorescente compacta
fluorescente compacta
fluorescente compacta
fluorescente linear
fluorescente linear
fluorescente linear

convencional
convencional
convencional
eletrnico
eletrnico
eletrnico

1
1
1
1
1
1

4
4
2
4
2
1

38
38
38
80
80
54

38
38
38
80
80
54

fluorescente linear

eletrnico

54

54

fluorescente linear
fluorescente linear
fluorescente linear
-fluorescente linear
fluorescente linear
descarga elptica
fluorescente linear
fluorescente linear
fluorescente compacta
fluorescente linear
fluorescente linear
fluorescente linear
fluorescente linear
fluorescente compacta
fluorescente linear
fluorescente linear
fluorescente linear
fluorescente linear

eletrnico
eletrnico
eletrnico
-eletrnico
eletrnico
eletrnico
eletrnico
eletrnico
convencional
eletrnico
eletrnico
eletrnico
eletrnico
convencional
eletrnico
eletrnico
eletrnico
eletrnico

2
2
2
-2
2
1
1
1
1
1
2
2
2
1
2
1
1
2

1
2
2
-8
4
4
4
2
3
2
2
2
7
2
1
4
2
4

54
36
36
-80
36
400
49
35
38
80
54
49
54
38
80
49
35
58

108
72
72
-160
72
400
49
35
38
80
108
98
108
38
160
49
35
116

Tipo Lmpada Eltrica

Nmero
Tipo Balastro Lmpadas por
luminria

Vapor Sdio Baixa


Presso

Eletrnico

ator de manuteno de 0,75 e a altura de trabalho de 0,75m.

Iluminao de Emergncia

Quantidade
Luminrias
16

Potncia
Potncia
Total
Lmpada
Luminria[
[W]
W]
70

70

Piso 0 Serv. Adm.


Piso 1
Nave Fabril

N Luminrias

S luminria
[VA]

S [kVA]

16
13
10

12
12
12

0.192
0.156
0.12

Potncia
Total
Luminrias
[W]

S [VA]

152
152
76
320
160
54

191.34
191.34
95.67
342.40
171.20
57.78

0.191
0.191

108

115.56

0.116

108
144
144
-1280
288
1600
196
70
114
160
216
196
756
76
160
196
70
464

115.56
154.08
154.08
-1369.60
308.16
1712.00
209.72
74.90
143.51
171.20
231.12
209.72
808.92
95.67
171.20
209.72
74.90
496.48

0.116
0.154
0.154
-1.370
0.308
1.712
0.210
0.075
0.144
0.171
0.231
0.210
0.809
0.096
0.171
0.210
0.075
0.496

Potncia
Total
Luminrias
[W]

S [VA]

S [VA]

1120

1198.4

1.1984

S [kVA]

0.096
0.342
0.171

Perdas no balastro

1.07

0.058

Tipo de balastro
Convencional
Eletrnico

F.P.
0.85
1

Anexo 05

Locais a Climatizar

Piso 0

Piso 1

Nota:

Secretaria
Informtica
Gabinete 1
Gabinete 2
Gabinete Gerncia
Sala de Reunies
Sala de Desenho

Unidades de Exterior

Pot. Aquecimento
Unidade Exterior [kW]

S [kVA]

1 - MXZ-4C71VA

1.705

1.722

1 - MXZ-6C120VA

3.7

3.737

Ar Condicionado da Mitsubishi Electric Multi-Split srie MXZ inverter

05

Unidades de Interior

Capacidade de
Aquecimento
Unidades
Interiores [kW]

S [kVA]

1 Mural MSZ-GE35VA
1 Mural MSZ-SF15VA
2 Murais MSZ-GE25VA
1 Mural MSZ-GE35VA
1 Mural MSZ-GE25VA
1 Mural MSZ-GE35VA
2 Murais MSZ-GE42VA

0.955
0.017
1.4
0.955
0.7
0.955
2.92

0.965
0.017
1.414
0.965
0.707
0.965
2.949

Total S [kVA]

13.44

rie MXZ inverter

F.P.

0.99

Anexo 06 - Dimensionamento das Potncias Previsveis Por Quadro Elctrico


Quadro Elctrico Q_PT

Designao do circuito

S (kVA)

Tomadas
Iluminao Segurana P.T.
Iluminao P.T.
Quadro Gerador

3.68
0.01
0.07
538.40

ku (1)

1.00

ks (2)

SFinal (kVA)

0.65

2.39
0.01
0.07
538.40

1.00

540.88
1.00
1.00
540.88

STotal (kVA)
Coeficiente de simultaneidade de quadro industrial (ks)
Factor de evoluo de cargas (ke) (3)
SQuadro (kVA)

Quadro Elctrico Q_UPS_P1

Designao do circuito

S (kVA)

ku (1)

ks (2)

SFinal (kVA)

Tomadas Monofsicas- Sala Desenho a)


Tomadas Monofsicas- Sala Desenho b)
Tomadas Monofsicas- Sala Desenho b) + Gabinete 2 a)
Tomadas Monofsicas- Gabinete 2 b) + Sala Reunies + Gerncia

3.68
3.68
3.68
3.68

1.00

0.65

2.39
2.39
2.39
2.39
9.57
0.80
1.20
9.19

STotal (kVA)
Coeficiente de simultaneidade de quadro industrial (ks)
Factor de evoluo de cargas (ke) (3)
SQuadro (kVA)
Quadro Elctrico Q_UPS_P0

Designao do circuito

S (kVA)

Tomadas monofsicas - Gab. 1 a)


Tomadas monofsicas - Gab. 1 b)
Tomadas Monofsicas - Secretaria/Recepo + Informtica
Quadro Q_UPS_P1

3.68
3.68
3.68
9.19

Nota :

Tendo em conta a SQuadro escolhemos uma UPS de 20kVA

Nota:
1) Factor de utlizao (ku), exprime o regime de funcionamento de um receptor
2) Coeficiente de Simultaneidade (ks), caracteriza o regime de funcionamento de uma dada instalao
3) Factor de evoluo de cargas (ke)

ks (2)

1.00

0.65

1.00

1.00

SFinal (kVA)
2.39
2.39
2.39
9.19
16.36
0.80
1.20
15.71

STotal (kVA)
Coeficiente de simultaneidade de quadro industrial (ks)
Factor de evoluo de cargas (ke) (3)
SQuadro (kVA)

Desta forma ser considerada como S_UPS o valor de 20kVA

ku (1)

20 kVA

Anexo 06 - Dimensionamento das Potncias Previsveis Por Quadro Elctrico (Continuao 1)

Quadro Elctrico Q_SERV_ADM_P1

Designao do circuito

S (kVA)

Iluminao Interior - I.S. Gerncia


Iluminao Interior Gerncia
Iluminao Interior - Escadas
Iluminao Interior - Corredor 1
Iluminao Interior - Corredor 2
Iluminao Interior - Sala de Reunies
Iluminao Interior - Gabinete 2
Iluminao Interior - Sala de Desenho
Iluminao de Emergncia
Iluminao Interior - Instalaes Sanitrias
Tomadas Uso Geral - Gerncia
Tomadas Uso Geral - Sala Reunies
Tomadas Uso Geral - Gabinete 2
Tomadas Uso Geral - Sala Desenho + I.S.
Climatizao Gerncia
Climatizao Sala Reunies
Climatizao Gabinete 2
Climatizao -- Sala de Desenho
Climatizao - Unidade Exterior

0.14
0.17
0.07
0.10
0.10
0.23
0.21
0.81
0.16
0.10
3.68
3.68
3.68
3.68
0.71
0.96
0.96
2.95
3.74

ku (1)

ks (2)

1.00

1.00

0.65

SFinal (kVA)
0.14
0.17
0.07
0.10
0.10
0.23
0.21
0.81
0.16
0.10
2.39
2.39
2.39
2.39
0.46
0.63
0.63
1.92
2.43
17.73
0.80
1.20
17.02

STotal (kVA)
Coeficiente de simultaneidade de quadro industrial (ks)
Factor de evoluo de cargas (ke) (3)
SQuadro (kVA)
Quadro Elctrico Q_ENTRADA

Designao do circuito

S (kVA)

Mquina 1
Mquina 2
Mquina 3
Mquina 4
Mquina 5
Mquina 6
Mquina 7
Mquina 8
Mquina 9
Mquina 10
Mquina 11
Mquina 12
Proteco Telerruptores
Iluminao Nave 1
Iluminao Nave 2
Iluminao Nave 3
Iluminao Nave 4
Iluminao Nave 5
Iluminao Nave 6
Iluminao Nave 7
Iluminao Emergncia
Iluminao Exterior
Quadros Tomadas (1, 2 e 3)
Quadros Tomadas ( 4 a 7)
Portes Exterior
Alarme
Q_SERV_ADM_P0

65.00
65.00
45.00
45.00
35.00
6.25
3.00
18.37
11.22
1.88
10.71
5.88
-0.86
0.86
1.37
0.31
0.50
0.15
0.15
0.12
1.20
11.09
11.09
0.60
0.10
51.73

STotal (kVA)
Coeficiente de simultaneidade de quadro industrial (ks)
Factor de evoluo de cargas (ke) (3)
SQuadro (kVA)
SQuadro Com previso da ampliao para dobro (kVA)

Nota:
1) Factor de utlizao (ku), exprime o regime de funcionamento de um receptor
2) Coeficiente de Simultaneidade (ks), caracteriza o regime de funcionamneto de uma dada instalao
3) Factor de evoluo de cargas (ke)

ku (1)

ks (2)

0.70

-1.00

1.00

0.20
1.00

SFinal (kVA)
45.50
45.50
31.50
31.50
24.50
4.38
2.10
12.86
7.86
1.31
7.50
4.12
0.00
0.86
0.86
1.37
0.31
0.50
0.15
0.15
0.12
1.20
2.22
2.22
0.12
0.00
51.73
280.42
0.80
1.20
269.20
538.40

Anexo 06 - Dimensionamento das Potncias Previsveis Por Quadro Elctrico (Continuao 3)


Quadro Elctrico Q_SERV_ADM_P0

Designao do circuito

S (kVA)

Iluminao - I.S. H + I.S. M


Iluminao Interior - Refeitrio
Iluminao Interior - Escadas
Iluminao Interior - Gabinete 1
Iluminao Interior - Corredor Parte 1)
Iluminao Interior - Corredor parte 2)
Iluminao Interior - Secretaria/Receo
Iluminao Interior - Informtica
Iluminao Interior - I.S.
Iluminao Interior - Hall
Iluminao Emergncia
Letreiro
Tomadas Uso Geral- Corredor+escadas+I.S. H e M
Tomadas Uso Geral- Refeitrio
Tomadas Uso Geral- Gabinete 1
Tomadas Uso Geral- Secretaria
Tomadas Uso Geral- Informtica + Hall
Climatizao - Unidade Exterior
Climatizao - Informtica
Climatizao - Gabinete 1
Climatizao - Secretaria
UPS
Q_SERV_ADM_P1

0.38
0.12
0.07
0.34
0.10
0.10
0.23
0.12
0.10
0.17
0.19
0.30
3.68
3.68
3.68
3.68
3.68
1.72
0.02
1.41
0.96
20.00
17.02

ku (1)

ks (2)

SFinal (kVA)
0.38
0.12
0.07
0.34
0.10
0.10
0.23
0.12
0.10
0.17
0.19
0.30
2.39
2.39
2.39
2.39
2.39
1.12
0.01
0.92
0.63
20.00
17.02

1.00

1.00

0.65

1.00

STotal (kVA)
Factor de evoluo de cargas (ke) (3)
Coeficiente de simultaneidade de quadro industrial (ks)
SQuadro (kVA)

53.89
1.2
0.8
51.72978653

Quadro Elctrico Q_Gerador

Designao do circuito

S (kVA)

ku (1)

ks (2)

ke (2)

Quadro Elctrico Q_ENTRADA

538.40

1.00

1.00

1.00

SFinal (kVA)
538.40

SQuadro (kVA)

538.40

Potncia do Posto de Transformao (kVA)


Potncia do Gerador Escolhido (kVA)

630
630

Nota:
1) Factor de utlizao (ku), exprime o regime de funcionamento de um receptor
2) Coeficiente de Simultaneidade (ks), caracteriza o regime de funcionamneto de uma dada instalao
3) Factor de evoluo de cargas (ke)
Para o clculo da potncia dos circuitos de climatizao consideraram-se os valores reais apresentados na folha Climatizao
No Q.G.B.T s se considerou um factor de evoluo de cargas (ke), para os circuitos receptores ligados directamente ao Q.G.B.T, porque os restantes quadros j foram anteriormente afectados pelo factor
de evoluo de cargas

Anexo 07 - Dimensionamento dos Cabos a Utilizar para os Circuitos Alimentados pelo Quadro Electrico Q_UPS_P1

1. Dimensionamento dos Cabos e Verificao das Condies de Proteco

Circuito
N

Designao

1
2
3
4

Tomadas
Iluminao Segurana P.T.
Iluminao P.T.
Quadro Gerador

Caractersticas do Cabo

S (kVA)

Tenso
(V)

In (A)

Arranque
(1)

Ia (A)
(4)

Ib (A)

Disposio

3.68
0.01
0.07
630.00

230
230
230
400

16.00
0.05
0.31
909.33

-----------------

0,00
0,00
0,00
0,00

#VALUE!
#VALUE!
#VALUE!
#VALUE!

Embebido
Embebido
Embebido
Embebido

S (kVA)

Tenso
(V)

Ib (A)

L (m)

cos()

sen()

3.68
0.01
0.07
630.00

230
230
230
400

#VALUE!
#VALUE!
#VALUE!
#VALUE!

2.00
2.50
2.00
15.00

0.80

0.52

Cabo a Utilizar (mm2) S (mm)

Iz (A)

Numero de
Cabos

A05VV-U 3G2,5
A05VV-U 3G1,5
A05VV-U 3G1,5
4x(H07XV 3x120 + N)

36
27
27
1248

2.5
1.5
1.5
120

Factores de Correco
k3 (2)

k4 (3)

At 3
At 3
At 3
4 a 6 ou mais

1
1
1
1

0.80
0.80
0.80
1.00

l
(mH/km)
0.00
0.00
0.00
0.22

r (90C)
(/km)
(5)
9.448
15.429
15.429
0.195

Disjuntor
Iz' = k3*k4*Iz (A)
28.80
21.60
21.60
1248.00

Condies de verificao

1,45 x Iz'

I2 (A)

In (A)

Ib In Iz'

I2 1,45 Iz'

41.76
31.32
31.32
1809.60

21.60
13.50
13.50
1350.00

16
10
10
1000

#VALUE!
#VALUE!
#VALUE!
#VALUE!

Verifica
Verifica
Verifica
Verifica

2. Verificao da Queda de Tenso para o Perodo de Funcionamento em Regime Nominal

Circuito
N

Designao

1
2
3
4

Tomadas
Iluminao Segurana P.T.
Iluminao P.T.
Quadro Gerador

Caractersticas do cabo
r (20C)
2
(/km)
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
4x(H07XV 3x120 + N)
120
0.153

Cabo a utilizar (mm ) S (mm)

r (70C) (/km)
x (/km)
(6)
8.866
14.478
14.478
0.183

Nota:
1) Na condio de arranque, considerou-se para todas as mquinas a utilizao de VEV (Variador Electrnico de Velocidade)
2) Factor de correco para temperatura ambiente diferente de 20C (Cabos ao ar), compensao para 30 - K3
3) Factor de correco para cabos instalados ao ar em grupos, com distncia inferior ao dimetro entre si - K4
4) Ia - Intensidade de corrente de arranque (A)
5) Considerou-se que a temperatura da alma condutora, do condutor isolado a polietileno reticulado (PRC), de 90C, conforme dados do fabricante
6) Considerou-se que a temperatura da alma condutora, do condutor isolado a policloreto de vinilo (PVC), de 70C, conforme dados do fabricante
7) No clculo da reactncia utilizou-se uma frequncia de 50 Hz, frequncia adoptada na Europa
8) Queda de tenso entre a origem da instalao e o aparelho de utilizao nas condies mais desfavoravis. Para a queda de tenso referente ao perodo de funcionamento em regime nominal considera-se uma Umx de 3% para a iluminao e 5% para os outros usos
Nos circuitos de 1 a 4 o cabo vai em esteira at proximo da direco do que vai alimentar, e a partir desse ponto segue vista
De salientar ainda que em todas as situaes em que a alimentao dos referidos receptores no se efectue directamente do Q.G.B.T, os clculos da queda de tenso devero tomar em conta todas as quedas de tenso verificadas nas canalizaes situadas a montante

0.000
0.000
0.000
0.069

Queda de tenso
(7)

U (V)

U (%)

#VALUE!
#VALUE!
#VALUE!
#VALUE!

#VALUE!
#VALUE!
#VALUE!
#VALUE!

Condies de Verificao (8)


Outros Usos
Iluminao
U 5%
U 3%
#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
-----

Anexo 08 - Dimensionamento dos Cabos a Utilizar para os Circuitos Alimentados pelo Quadro Electrico Q_UPS_P1

1. Dimensionamento dos Cabos e Verificao das Condies de Proteco

Circuito
N

Designao

Quadro Elctrico Q_ENTRADA

Caractersticas do Cabo

S (kVA)

Tenso
(V)

In (A)

Arranque
(1)

Ia (A)
(4)

Ib (A)

Disposio

630.00

400

909.33

-----

0,00

#VALUE!

Embebido

S (kVA)

Tenso
(V)

Ib (A)

L (m)

cos()

sen()

630.00

400

#VALUE!

6.50

0.80

0.52

Cabo a Utilizar (mm2) S (mm)

Iz (A)

Numero de
Cabos

4x(H07XV 3x120 + N)

1248

120

Factores de Correco
k3 (2)

k4 (3)

4 a 6 ou mais

1.00

l
(mH/km)
0.22

r (90C)
(/km)
(5)
0.195

Disjuntor
Iz' = k3*k4*Iz (A)
1248.00

Condies de verificao

1,45 x Iz'

I2 (A)

In (A)

Ib In Iz'

I2 1,45 Iz'

1809.60

1350.00

1000

#VALUE!

Verifica

2. Verificao da Queda de Tenso para o Perodo de Funcionamento em Regime Nominal

Circuito
N

Designao

Quadro Elctrico Q_ENTRADA

Caractersticas do cabo
r (20C)
(/km)
4x(H07XV 3x120 + N)
120
0.153

Cabo a utilizar (mm2) S (mm)

r (70C) (/km)
x (/km)
(6)
0.183

0.069

Queda de tenso
(7)

U (V)

U (%)

#VALUE! #VALUE!

Condies de Verificao (8)


Outros Usos
Iluminao
U 5%
U 3%
#VALUE!
-----

Nota:
1) Na condio de arranque, considerou-se para todas as mquinas a utilizao de VEV (Variador Electrnico de Velocidade)
2) Factor de correco para temperatura ambiente diferente de 20C (Cabos ao ar), compensao para 30 - K3
3) Factor de correco para cabos instalados ao ar em grupos, com distncia inferior ao dimetro entre si - K4
4) Ia - Intensidade de corrente de arranque (A)
5) Considerou-se que a temperatura da alma condutora, do condutor isolado a polietileno reticulado (PRC), de 90C, conforme dados do fabricante
6) Considerou-se que a temperatura da alma condutora, do condutor isolado a policloreto de vinilo (PVC), de 70C, conforme dados do fabricante
7) No clculo da reactncia utilizou-se uma frequncia de 50 Hz, frequncia adoptada na Europa
8) Queda de tenso entre a origem da instalao e o aparelho de utilizao nas condies mais desfavoravis. Para a queda de tenso referente ao perodo de funcionamento em regime nominal considera-se uma Umx de 3% para a iluminao e 5% para os outros usos
Nos circuitos de 1 a 4 o cabo vai em esteira at proximo da direco do que vai alimentar, e a partir desse ponto segue vista
De salientar ainda que em todas as situaes em que a alimentao dos referidos receptores no se efectue directamente do Q.G.B.T, os clculos da queda de tenso devero tomar em conta todas as quedas de tenso verificadas nas canalizaes situadas a montante

Y-

Anexo 09- Dimensionamento dos Cabos a Utilizar para os Circuitos Alimentados pelo Quadro Electrico Q_Adm

1. Dimensionamento dos Cabos e Verificao das Condies de Proteco

Circuito
N

Designao

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27

Mquina 1
Mquina 2
Mquina 3
Mquina 4
Mquina 5
Mquina 6
Mquina 7
Mquina 8
Mquina 9
Mquina 10
Mquina 11
Mquina 12
Proteco Telerruptores
Iluminao Nave 1
Iluminao Nave 2
Iluminao Nave 3
Iluminao Nave 4
Iluminao Nave 5
Iluminao Nave 6
Iluminao Nave 7
Iluminao Emergncia
Iluminao Exterior
Quadros Tomadas (1, 2 e 3)
Quadros Tomadas ( 4 a 7)
Portes Exterior
Alarme
Q_SERV_ADM_P0

Caractersticas do Cabo

S (kVA)

Tenso
(V)

In (A)

Arranque
(1)

Ia (A)
(4)

Ib (A)

Disposio

65.00
65.00
45.00
45.00
35.00
6.25
3.00
18.37
11.22
1.88
10.71
5.88
-0.86
0.86
1.37
0.31
0.50
0.15
0.15
0.12
1.20
11.09
11.09
0.60
0.10
51.73

400
400
400
400
400
400
230
400
400
400
400
400
230
230
230
230
230
230
230
230
230
400
400
400
230
400
400

93.82
93.82
64.95
64.95
50.52
9.02
13.04
26.51
16.20
2.71
15.46
8.49
#VALUE!
3.72
3.72
5.95
1.34
2.16
0.67
0.67
0.52
1.73
16.01
16.01
2.61
0.14
74.67

-------------------------------------------------------------------------------------------------------------

0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Calha
Calha
Calha
Calha
Calha
Calha
Calha
Calha
Calha
Calha
Calha
Calha
----Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Enterrado
Esteira
Esteira
Enterrado
Esteira
Esteira

S (kVA)

Tenso
(V)

Ib (A)

L (m)

cos()

sen()

65.00
65.00
45.00
45.00
35.00
6.25
3.00
18.37
11.22
1.88
10.71
5.88
-0.86
0.86
1.37
0.31
0.50
0.15
0.15
0.12
1.20
11.09
11.09
0.60
0.10
51.73

400
400
400
400
400
400
230
400
400
400
400
400
230
230
230
230
230
230
230
230
230
400
400
400
230
400
400

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

15.98
10.11
30.37
34.47
39.07
7.40
12.00
31.26
29.51
23.83
25.23
25.42
0.00
10.04
18.24
48.38
38.21
27.91
27.91
27.91
0.50
366.45
34.92
60.79
105.95
2.00
47.89

Cabo a Utilizar (mm ) S (mm)


A05VV-R 5G50
A05VV-R 5G50
A05VV-R 5G50
A05VV-R 5G35
A05VV-R 5G35
A05VV-U 5G2,5
A05VV-U 3G2,5
A05VV-U 5G6
A05VV-U 5G4
A05VV-U 5G2,5
A05VV-U 5G4
A05VV-U 5G2,5
A05VV-U 3G1,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 5G2,5
A05VV-U 5G6
A05VV-U 5G6
A05VV-U 3G2,5
A05VV-U 3G1,5
A05VV-R 5G35

50
50
50
35
35
2.5
2.5
6
4
2.5
4
2.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
6
6
2.5
1.5
35

Iz (A)

Numero de
Cabos

153
153
153
126
126
22
36
43
34
22
34
22
27
36
36
36
36
36
36
36
36
22
43
43
36
27
126

Factores de Correco
k3 (2)

k4 (3)

At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3

0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88

0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80

l
(mH/km)
0.24
0.24
0.24
0.24
0.24
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.24

r (90C)
(/km)
(5)
0.493
0.493
0.493
0.668
0.668
9.448
9.448
3.927
5.878
9.448
5.878
9.448
15.429
9.448
9.448
9.448
9.448
9.448
9.448
9.448
9.448
9.448
3.927
3.927
9.448
15.429
0.668

Disjuntor
Iz' = k3*k4*Iz (A)
107.71
107.71
107.71
88.70
88.70
15.49
25.34
30.27
23.94
15.49
23.94
15.49
19.01
25.34
25.34
25.34
25.34
25.34
25.34
25.34
25.34
15.49
30.27
30.27
25.34
19.01
88.70

Condies de verificao

1,45 x Iz'

I2 (A)

In (A)

Ib In Iz'

I2 1,45 Iz'

156.18
156.18
156.18
128.62
128.62
22.46
36.75
43.89
34.71
22.46
34.71
22.46
27.56
36.75
36.75
36.75
36.75
36.75
36.75
36.75
36.75
22.46
43.89
43.89
36.75
27.56
128.62

135.00
135.00
108.00
108.00
108.00
13.50
21.60
39.00
27.00
13.50
27.00
16.20
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
33.80
33.80
21.60
13.50
108.00

100
100
80
80
80
10
16
30
20
10
20
12
10
10
10
10
10
10
10
10
10
10
25
25
16
10
80

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica

2. Verificao da Queda de Tenso para o Perodo de Funcionamento em Regime Nominal

Circuito
N

Designao

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27

Mquina 1
Mquina 2
Mquina 3
Mquina 4
Mquina 5
Mquina 6
Mquina 7
Mquina 8
Mquina 9
Mquina 10
Mquina 11
Mquina 12
Proteco Telerruptores
Iluminao Nave 1
Iluminao Nave 2
Iluminao Nave 3
Iluminao Nave 4
Iluminao Nave 5
Iluminao Nave 6
Iluminao Nave 7
Iluminao Emergncia
Iluminao Exterior
Quadros Tomadas (1, 2 e 3)
Quadros Tomadas ( 4 a 7)
Portes Exterior
Alarme
Q_SERV_ADM_P0

0.80

0.52

Caractersticas do cabo
r (20C)
(/km)
A05VV-R 5G50
50
0.387
A05VV-R 5G50
50
0.387
A05VV-R 5G50
50
0.387
A05VV-R 5G35
35
0.524
A05VV-R 5G35
35
0.524
A05VV-U 5G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 5G6
6
3.08
A05VV-U 5G4
4
4.61
A05VV-U 5G2,5
2.5
7.41
A05VV-U 5G4
4
4.61
A05VV-U 5G2,5
2.5
7.41
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 5G2,5
2.5
7.41
A05VV-U 5G6
6
3.08
A05VV-U 5G6
6
3.08
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G1,5
1.5
12.1
A05VV-R 5G35
35
0.524

Cabo a utilizar (mm2) S (mm)

Nota:
1) Na condio de arranque, considerou-se para todas as mquinas a utilizao de VEV (Variador Electrnico de Velocidade)
2) Factor de correco para temperatura ambiente diferente de 20C (Cabos ao ar), compensao para 30 - K3
3) Factor de correco para cabos instalados ao ar em grupos, com distncia inferior ao dimetro entre si - K4
4) Ia - Intensidade de corrente de arranque (A)
5) Considerou-se que a temperatura da alma condutora, do condutor isolado a polietileno reticulado (PRC), de 90C, conforme dados do fabricante
6) Considerou-se que a temperatura da alma condutora, do condutor isolado a policloreto de vinilo (PVC), de 70C, conforme dados do fabricante
7) No clculo da reactncia utilizou-se uma frequncia de 50 Hz, frequncia adoptada na Europa
8) Queda de tenso entre a origem da instalao e o aparelho de utilizao nas condies mais desfavoravis. Para a queda de tenso referente ao perodo de funcionamento em regime nominal considera-se uma Umx de 3% para a iluminao e 5% para os outros usos
Nos circuitos de 1 a 3 o cabo vai em esteira at proximo da direco do que vai alimentar, e a partir desse ponto segue vista
De salientar ainda que em todas as situaes em que a alimentao dos referidos receptores no se efectue directamente do Q.G.B.T, os clculos da queda de tenso devero tomar em conta todas as quedas de tenso verificadas nas canalizaes situadas a montante

r (70C) (/km)
x (/km)
(6)
0.463
0.463
0.463
0.627
0.627
8.866
8.866
3.685
5.516
8.866
5.516
8.866
14.478
8.866
8.866
8.866
8.866
8.866
8.866
8.866
8.866
8.866
3.685
3.685
8.866
14.478
0.627

0.075
0.075
0.075
0.075
0.075
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.075

Queda de tenso
(7)

U (V)

U (%)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Condies de Verificao (8)


Outros Usos
Iluminao
U 5%
U 3%
#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----------------#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
-----

Anexo 10- Dimensionamento dos Cabos a Utilizar para os Circuitos Alimentados pelo Quadro Electrico Q_SERV_ADM_P0

1. Dimensionamento dos Cabos e Verificao das Condies de Proteco

Circuito
N

Designao

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

Iluminao - I.S. H + I.S. M


Iluminao Interior - Refeitrio
Iluminao Interior - Escadas
Iluminao Interior - Gabinete 1
Iluminao Interior - Corredor Parte 1)
Iluminao Interior - Corredor parte 2)
Iluminao Interior - Secretaria/Receo
Iluminao Interior - Informtica
Iluminao Interior - I.S.
Iluminao Interior - Hall
Iluminao Emergncia
Letreiro
Tomadas Uso Geral- Corredor+escadas+I.S. H e M
Tomadas Uso Geral- Refeitrio
Tomadas Uso Geral- Gabinete 1
Tomadas Uso Geral- Secretaria
Tomadas Uso Geral- Informtica + Hall
Climatizao - Unidade Exterior
Climatizao - Informtica
Climatizao - Gabinete 1
Climatizao - Secretaria
UPS
Q_SERV_ADM_P1

Caractersticas do Cabo

S (kVA)

Tenso
(V)

In (A)

Arranque
(1)

Ia (A)
(4)

Ib (A)

Disposio

0.38
0.12
0.07
0.34
0.10
0.10
0.23
0.12
0.10
0.17
0.19
0.30
3.68
3.68
3.68
3.68
3.68
1.72
0.02
1.41
0.96
20.00
17.02

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
400
400

1.66
0.50
0.33
1.49
0.46
0.46
1.00
0.50
0.42
0.74
0.83
1.30
16.00
16.00
16.00
16.00
16.00
7.49
0.07
6.15
4.19
28.87
24.57

---------------------------------------------------------------------------------------------

0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira

S (kVA)

Tenso
(V)

Ib (A)

L (m)

cos()

sen()

0.38
0.12
0.07
0.34
0.10
0.10
0.23
0.12
0.10
0.17
0.19
0.30
3.68
3.68
3.68
3.68
3.68
1.72
0.02
1.41
0.96
20.00
17.02

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
400
400

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

30.72
22.77
24.98
18.90
15.65
8.41
11.54
6.68
5.29
8.04
0.50
11.33
33.24
34.22
30.04
20.86
18.03
15.20
5.43
25.43
12.33
2.82
3.00

Cabo a Utilizar (mm ) S (mm)


A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 5G6
A05VV-U 5G6

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
6
6

Iz (A)

Numero de
Cabos

27
27
27
27
27
27
27
27
27
27
27
27
36
36
36
36
36
36
36
36
36
43
43

Factores de Correco
k3 (2)

k4 (3)

At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3

0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88

0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80

l
(mH/km)
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

r (90C)
(/km)
(5)
15.429
15.429
15.429
15.429
15.429
15.429
15.429
15.429
15.429
15.429
15.429
15.429
9.448
9.448
9.448
9.448
9.448
9.448
9.448
9.448
9.448
3.927
3.927

Disjuntor
Iz' = k3*k4*Iz (A)
19.01
19.01
19.01
19.01
19.01
19.01
19.01
19.01
19.01
19.01
19.01
19.01
25.34
25.34
25.34
25.34
25.34
25.34
25.34
25.34
25.34
30.27
30.27

Condies de verificao

1,45 x Iz'

I2 (A)

In (A)

Ib In Iz'

I2 1,45 Iz'

27.56
27.56
27.56
27.56
27.56
27.56
27.56
27.56
27.56
27.56
27.56
27.56
36.75
36.75
36.75
36.75
36.75
36.75
36.75
36.75
36.75
43.89
43.89

13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
21.60
21.60
21.60
21.60
21.60
21.60
21.60
21.60
21.60
39.00
33.80

10
10
10
10
10
10
10
10
10
10
10
10
16
16
16
16
16
16
16
16
16
30
25

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica

2. Verificao da Queda de Tenso para o Perodo de Funcionamento em Regime Nominal

Circuito
N

Designao

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

Iluminao - I.S. H + I.S. M


Iluminao Interior - Refeitrio
Iluminao Interior - Escadas
Iluminao Interior - Gabinete 1
Iluminao Interior - Corredor Parte 1)
Iluminao Interior - Corredor parte 2)
Iluminao Interior - Secretaria/Receo
Iluminao Interior - Informtica
Iluminao Interior - I.S.
Iluminao Interior - Hall
Iluminao Emergncia
Letreiro
Tomadas Uso Geral- Corredor+escadas+I.S. H e M
Tomadas Uso Geral- Refeitrio
Tomadas Uso Geral- Gabinete 1
Tomadas Uso Geral- Secretaria
Tomadas Uso Geral- Informtica + Hall
Climatizao - Unidade Exterior
Climatizao - Informtica
Climatizao - Gabinete 1
Climatizao - Secretaria
UPS
Q_SERV_ADM_P1

0.80

0.52

Caractersticas do cabo
r (20C)
2
(/km)
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 5G6
6
3.08
A05VV-U 5G6
6
3.08

Cabo a utilizar (mm ) S (mm)

r (70C) (/km)
x (/km)
(6)
14.478
14.478
14.478
14.478
14.478
14.478
14.478
14.478
14.478
14.478
14.478
14.478
8.866
8.866
8.866
8.866
8.866
8.866
8.866
8.866
8.866
3.685
3.685

0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

Queda de tenso
(7)

U (V)

U (%)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Condies de Verificao (8)


Outros Usos
Iluminao
U 5%
U 3%
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
-----

Nota:
1) Na condio de arranque, considerou-se para todas as mquinas a utilizao de VEV (Variador Electrnico de Velocidade)
2) Factor de correco para temperatura ambiente diferente de 20C (Cabos ao ar), compensao para 30 - K3
3) Factor de correco para cabos instalados ao ar em grupos, com distncia inferior ao dimetro entre si - K4
4) Ia - Intensidade de corrente de arranque (A)
5) Considerou-se que a temperatura da alma condutora, do condutor isolado a polietileno reticulado (PRC), de 90C, conforme dados do fabricante
6) Considerou-se que a temperatura da alma condutora, do condutor isolado a policloreto de vinilo (PVC), de 70C, conforme dados do fabricante
7) No clculo da reactncia utilizou-se uma frequncia de 50 Hz, frequncia adoptada na Europa
8) Queda de tenso entre a origem da instalao e o aparelho de utilizao nas condies mais desfavoravis. Para a queda de tenso referente ao perodo de funcionamento em regime nominal considera-se uma Umx de 3% para a iluminao e 5% para os outros usos
Nos circuitos de 1 a 3 o cabo vai em esteira at proximo da direco do que vai alimentar, e a partir desse ponto segue vista
De salientar ainda que em todas as situaes em que a alimentao dos referidos receptores no se efectue directamente do Q.G.B.T, os clculos da queda de tenso devero tomar em conta todas as quedas de tenso verificadas nas canalizaes situadas a montante

-----

Anexo 11- Dimensionamento dos Cabos a Utilizar para os Circuitos Alimentados pelo Quadro Electrico Q_SERV_ADM_P1

1. Dimensionamento dos Cabos e Verificao das Condies de Proteco

Circuito
N

Designao

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Iluminao Interior - I.S. Gerncia


Iluminao Interior Gerncia
Iluminao Interior - Escadas
Iluminao Interior - Corredor 1
Iluminao Interior - Corredor 2
Iluminao Interior - Sala de Reunies
Iluminao Interior - Gabinete 2
Iluminao Interior - Sala de Desenho
Iluminao de Emergncia
Iluminao Interior - Instalaes Sanitrias
Tomadas Uso Geral - Gerncia
Tomadas Uso Geral - Sala Reunies
Tomadas Uso Geral - Gabinete 2
Tomadas Uso Geral - Sala Desenho + I.S.
Climatizao Gerncia
Climatizao Sala Reunies
Climatizao Gabinete 2
Climatizao -- Sala de Desenho
Climatizao - Unidade Exterior

Caractersticas do Cabo

S (kVA)

Tenso
(V)

In (A)

Arranque
(1)

Ia (A)
(4)

Ib (A)

Disposio

0.14
0.17
0.07
0.10
0.10
0.23
0.21
0.81
0.16
0.10
3.68
3.68
3.68
3.68
0.71
0.96
0.96
2.95
3.74

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230

0.62
0.74
0.33
0.46
0.46
1.00
0.91
3.52
0.68
0.42
16.00
16.00
16.00
16.00
3.07
4.19
4.19
12.82
16.25

-----------------------------------------------------------------------------

0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira
Esteira

S (kVA)

Tenso
(V)

Ib (A)

L (m)

cos()

sen()

0.14
0.17
0.07
0.10
0.10
0.23
0.21
0.81
0.16
0.10
3.68
3.68
3.68
3.68
0.71
0.96
0.96
2.95
3.74

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

27.73
30.98
24.98
15.65
8.41
23.89
16.85
21.45
0.50
3.95
40.39
34.01
28.63
34.25
35.38
26.04
28.31
25.30
26.32

Cabo a Utilizar (mm ) S (mm)


A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G1,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Iz (A)

Numero de
Cabos

27
27
27
27
27
27
27
27
27
27
36
36
36
36
36
36
36
36
36

Factores de Correco
k3 (2)

k4 (3)

At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3
At 3

0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88

0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80

l
(mH/km)
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

r (90C)
(/km)
(5)
15.429
15.429
15.429
15.429
15.429
15.429
15.429
15.429
15.429
15.429
9.448
9.448
9.448
9.448
9.448
9.448
9.448
9.448
9.448

Disjuntor
Iz' = k3*k4*Iz (A)
19.01
19.01
19.01
19.01
19.01
19.01
19.01
19.01
19.01
19.01
25.34
25.34
25.34
25.34
25.34
25.34
25.34
25.34
25.34

Condies de verificao

1,45 x Iz'

I2 (A)

In (A)

Ib In Iz'

I2 1,45 Iz'

27.56
27.56
27.56
27.56
27.56
27.56
27.56
27.56
27.56
27.56
36.75
36.75
36.75
36.75
36.75
36.75
36.75
36.75
36.75

13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
21.60
21.60
21.60
21.60
21.60
21.60
21.60
21.60
27.00

10
10
10
10
10
10
10
10
10
10
16
16
16
16
16
16
16
16
20

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica

2. Verificao da Queda de Tenso para o Perodo de Funcionamento em Regime Nominal

Circuito
N

Designao

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Iluminao Interior - I.S. Gerncia


Iluminao Interior Gerncia
Iluminao Interior - Escadas
Iluminao Interior - Corredor 1
Iluminao Interior - Corredor 2
Iluminao Interior - Sala de Reunies
Iluminao Interior - Gabinete 2
Iluminao Interior - Sala de Desenho
Iluminao de Emergncia
Iluminao Interior - Instalaes Sanitrias
Tomadas Uso Geral - Gerncia
Tomadas Uso Geral - Sala Reunies
Tomadas Uso Geral - Gabinete 2
Tomadas Uso Geral - Sala Desenho + I.S.
Climatizao Gerncia
Climatizao Sala Reunies
Climatizao Gabinete 2
Climatizao -- Sala de Desenho
Climatizao - Unidade Exterior

0.80

0.52

Caractersticas do cabo
r (20C)
(/km)
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G1,5
1.5
12.1
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41

Cabo a utilizar (mm2) S (mm)

Nota:
1) Na condio de arranque, considerou-se para todas as mquinas a utilizao de VEV (Variador Electrnico de Velocidade)
2) Factor de correco para temperatura ambiente diferente de 20C (Cabos ao ar), compensao para 30 - K3
3) Factor de correco para cabos instalados ao ar em grupos, com distncia inferior ao dimetro entre si - K4
4) Ia - Intensidade de corrente de arranque (A)
5) Considerou-se que a temperatura da alma condutora, do condutor isolado a polietileno reticulado (PRC), de 90C, conforme dados do fabricante
6) Considerou-se que a temperatura da alma condutora, do condutor isolado a policloreto de vinilo (PVC), de 70C, conforme dados do fabricante
7) No clculo da reactncia utilizou-se uma frequncia de 50 Hz, frequncia adoptada na Europa
8) Queda de tenso entre a origem da instalao e o aparelho de utilizao nas condies mais desfavoravis. Para a queda de tenso referente ao perodo de funcionamento em regime nominal considera-se uma Umx de 3% para a iluminao e 5% para os outros usos
Nos circuitos de 1 a 3 o cabo vai em esteira at proximo da direco do que vai alimentar, e a partir desse ponto segue vista
De salientar ainda que em todas as situaes em que a alimentao dos referidos receptores no se efectue directamente do Q.G.B.T, os clculos da queda de tenso devero tomar em conta todas as quedas de tenso verificadas nas canalizaes situadas a montante

r (70C) (/km)
x (/km)
(6)
14.478
14.478
14.478
14.478
14.478
14.478
14.478
14.478
14.478
14.478
8.866
8.866
8.866
8.866
8.866
8.866
8.866
8.866
8.866

0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

Queda de tenso
(7)

U (V)

U (%)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Condies de Verificao (8)


Outros Usos
Iluminao
U 5%
U 3%
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
-----

Anexo 12 - Dimensionamento dos Cabos a Utilizar para os Circuitos Alimentados pelo Quadro Electrico Q_UPS_P1

1. Dimensionamento dos Cabos e Verificao das Condies de Proteco

Circuito
N

Designao

1
2
3
4

Tomadas Monofsicas- Sala Desenho a)


Tomadas Monofsicas- Sala Desenho b)
Tomadas Monofsicas- Sala Desenho b) + Gabinete 2 a)
Tomadas Monofsicas- Gabinete 2 b) + Sala Reunies + Gerncia

Caractersticas do Cabo

S (kVA)

Tenso
(V)

In (A)

Arranque
(1)

Ia (A)
(4)

Ib (A)

Disposio

3.68
3.68
3.68
3.68

230
230
230
230

16.00
16.00
16.00
16.00

-----------------

0,00
0,00
0,00
0,00

#VALUE!
#VALUE!
#VALUE!
#VALUE!

Esteira
Esteira
Esteira
Esteira

S (kVA)

Tenso
(V)

Ib (A)

L (m)

cos()

sen()

3.68
3.68
3.68
3.68

230
230
230
230

#VALUE!
#VALUE!
#VALUE!
#VALUE!

21.34
12.91
22.68
52.16

0.80

0.52

Cabo a Utilizar (mm2) S (mm)


A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G4

2.5
2.5
2.5
4

Iz (A)

Numero de
Cabos

36
36
36
48

Factores de Correco
k3 (2)

k4 (3)

At 3
At 3
At 3
At 3

1
1
1
1

0.80
0.80
0.80
0.80

l
(mH/km)
0.00
0.00
0.00
0.00

r (90C)
(/km)
(5)
9.448
9.448
9.448
5.878

Disjuntor
Iz' = k3*k4*Iz (A)
28.80
28.80
28.80
38.40

Condies de verificao

1,45 x Iz'

I2 (A)

In (A)

Ib In Iz'

I2 1,45 Iz'

41.76
41.76
41.76
55.68

21.60
21.60
21.60
21.60

16
16
16
16

#VALUE!
#VALUE!
#VALUE!
#VALUE!

Verifica
Verifica
Verifica
Verifica

2. Verificao da Queda de Tenso para o Perodo de Funcionamento em Regime Nominal

Circuito
N

Designao

1
2
3
4

Tomadas Monofsicas- Sala Desenho a)


Tomadas Monofsicas- Sala Desenho b)
Tomadas Monofsicas- Sala Desenho b) + Gabinete 2 a)
Tomadas Monofsicas- Gabinete 2 b) + Sala Reunies + Gerncia

Caractersticas do cabo
r (20C)
2
(/km)
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G4
4
4.61

Cabo a utilizar (mm ) S (mm)

r (70C) (/km)
x (/km)
(6)
8.866
8.866
8.866
5.516

Nota:
1) Na condio de arranque, considerou-se para todas as mquinas a utilizao de VEV (Variador Electrnico de Velocidade)
2) Factor de correco para temperatura ambiente diferente de 20C (Cabos ao ar), compensao para 30 - K3
3) Factor de correco para cabos instalados ao ar em grupos, com distncia inferior ao dimetro entre si - K4
4) Ia - Intensidade de corrente de arranque (A)
5) Considerou-se que a temperatura da alma condutora, do condutor isolado a polietileno reticulado (PRC), de 90C, conforme dados do fabricante
6) Considerou-se que a temperatura da alma condutora, do condutor isolado a policloreto de vinilo (PVC), de 70C, conforme dados do fabricante
7) No clculo da reactncia utilizou-se uma frequncia de 50 Hz, frequncia adoptada na Europa
8) Queda de tenso entre a origem da instalao e o aparelho de utilizao nas condies mais desfavoravis. Para a queda de tenso referente ao perodo de funcionamento em regime nominal considera-se uma Umx de 3% para a iluminao e 5% para os outros usos
Nos circuitos de 1 a 4 o cabo vai em esteira at proximo da direco do que vai alimentar, e a partir desse ponto segue vista
De salientar ainda que em todas as situaes em que a alimentao dos referidos receptores no se efectue directamente do Q.G.B.T, os clculos da queda de tenso devero tomar em conta todas as quedas de tenso verificadas nas canalizaes situadas a montante

0.000
0.000
0.000
0.000

Queda de tenso
(7)

U (V)

U (%)

#VALUE!
#VALUE!
#VALUE!
#VALUE!

#VALUE!
#VALUE!
#VALUE!
#VALUE!

Condies de Verificao (8)


Outros Usos
Iluminao
U 5%
U 3%
#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
-----

Anexo 13 - Dimensionamento dos Cabos a Utilizar para os Circuitos Alimentados pelo Quadro Electrico Q_UPS_P0

1. Dimensionamento dos Cabos e Verificao das Condies de Proteco

Circuito
N

Designao

1
2
3
4

Tomadas monofsicas - Gab. 1 a)


Tomadas monofsicas - Gab. 1 b)
Tomadas Monofsicas - Secretaria/Recepo + Informtica
Quadro Q_UPS_P1

Caractersticas do Cabo

S (kVA)

Tenso
(V)

In (A)

Arranque
(1)

Ia (A)
(4)

Ib (A)

Disposio

3.68
3.68
3.68
9.19

230
230
230
400

16.00
16.00
16.00
13.26

-----------------

0,00
0,00
0,00
0,00

#VALUE!
#VALUE!
#VALUE!
#VALUE!

Esteira
Esteira
Esteira
Esteira

S (kVA)

Tenso
(V)

Ib (A)

L (m)

cos()

sen()

3.68
3.68
3.68
9.19

230
230
230
400

#VALUE!
#VALUE!
#VALUE!
#VALUE!

18.20
23.11
16.06
3.00

0.80

0.52

Cabo a Utilizar (mm2) S (mm)


A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 3G2,5
A05VV-U 5G4

2.5
2.5
2.5
4

Iz (A)

Numero de
Cabos

36
36
36
34

Factores de Correco
k3 (2)

k4 (3)

At 3
At 3
At 3
At 3

1
1
1
1

0.80
0.80
0.80
0.80

l
(mH/km)
0.00
0.00
0.00
0.00

r (90C)
(/km)
(5)
9.448
9.448
9.448
5.878

Disjuntor
Iz' = k3*k4*Iz (A)
28.80
28.80
28.80
27.20

Condies de verificao

1,45 x Iz'

I2 (A)

In (A)

Ib In Iz'

I2 1,45 Iz'

41.76
41.76
41.76
39.44

21.60
21.60
21.60
21.60

16
16
16
16

#VALUE!
#VALUE!
#VALUE!
#VALUE!

Verifica
Verifica
Verifica
Verifica

2. Verificao da Queda de Tenso para o Perodo de Funcionamento em Regime Nominal

Circuito
N

Designao

1
2
3
4

Tomadas monofsicas - Gab. 1 a)


Tomadas monofsicas - Gab. 1 b)
Tomadas Monofsicas - Secretaria/Recepo + Informtica
Quadro Q_UPS_P1

Caractersticas do cabo
r (20C)
2
(/km)
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 3G2,5
2.5
7.41
A05VV-U 5G4
4
4.61

Cabo a utilizar (mm ) S (mm)

r (70C) (/km)
x (/km)
(6)
8.866
8.866
8.866
5.516

Nota:
1) Na condio de arranque, considerou-se para todas as mquinas a utilizao de VEV (Variador Electrnico de Velocidade)
2) Factor de correco para temperatura ambiente diferente de 20C (Cabos ao ar), compensao para 30 - K3
3) Factor de correco para cabos instalados ao ar em grupos, com distncia inferior ao dimetro entre si - K4
4) Ia - Intensidade de corrente de arranque (A)
5) Considerou-se que a temperatura da alma condutora, do condutor isolado a polietileno reticulado (PRC), de 90C, conforme dados do fabricante
6) Considerou-se que a temperatura da alma condutora, do condutor isolado a policloreto de vinilo (PVC), de 70C, conforme dados do fabricante
7) No clculo da reactncia utilizou-se uma frequncia de 50 Hz, frequncia adoptada na Europa
8) Queda de tenso entre a origem da instalao e o aparelho de utilizao nas condies mais desfavoravis. Para a queda de tenso referente ao perodo de funcionamento em regime nominal considera-se uma Umx de 3% para a iluminao e 5% para os outros usos
Nos circuitos de 1 a 4 o cabo vai em esteira at proximo da direco do que vai alimentar, e a partir desse ponto segue vista
De salientar ainda que em todas as situaes em que a alimentao dos referidos receptores no se efectue directamente do Q.G.B.T, os clculos da queda de tenso devero tomar em conta todas as quedas de tenso verificadas nas canalizaes situadas a montante

0.000
0.000
0.000
0.000

Queda de tenso
(7)

U (V)

U (%)

#VALUE!
#VALUE!
#VALUE!
#VALUE!

#VALUE!
#VALUE!
#VALUE!
#VALUE!

Condies de Verificao (8)


Outros Usos
Iluminao
U 5%
U 3%
#VALUE!
----#VALUE!
----#VALUE!
----#VALUE!
-----

Anexo 14 - Verificao das Correntes de Curto-Circuito Mnimo e Simtrico e Verificao do Poder de Corte dos Aparelhos de Proteco

1. Impedncias a Utilizar para o Clculo das Correntes de Curto-Circuito Mnimo

Designao do Circuito
Q_UPS_P1
Q_UPS_P0
Q_SERV_ADM_P1
Q_SERV_ADM_P0
Q_ENTRADA
Q_GERADOR

Quadro UPS Piso 1


Quadro UPS Piso 0
Quadro Servios Administrativos Piso 1
Quadro Servios Administrativos Piso 0
Quadro Entrada
Quadro Gerador

S (kVA)

Tenso (V)

In (A)

9.19
16.36
17.02
51.73
630.00
630.00

400.00
400.00
400.00
400.00
400.00
400.00

13.26
23.62
24.57
74.67
909.33
909.33

Cabo a utilizar (mm2)

Sf (mm)

A05VV-U 5G4
A05VV-U 5G6
A05VV-U 5G6
A05VV-R 5G35
4x(H07XV 3x120 + N)
4x(H07XV 3x120 + N)

4
6
6
35
120
120

Caractersticas do cabo
Rf 20C
Sn (mm)
(/km)
4
0
6
3.08
6
3.08
16
0.524
70
0.153
70
0.153

Rn 20C
(/km)
0
3.08
3.08
1.15
0.268
0.268

L (m)

Rf 30C () Rn 30C ()

3.00
2.82
3.00
47.89
6.50
15.00

0.00E+00
4.51E-03
4.80E-03
1.30E-02
5.17E-04
1.19E-03

0.00E+00
4.51E-03
4.80E-03
2.86E-02
9.05E-04
2.09E-03

Anexo 14 - Verificao das Correntes de Curto-Circuito Mnimo e Simtrico e Verificao do Poder de Corte dos Aparelhos de Proteco (Continuao)

3. Impedncias a Utilizar para o Clculo das Correntes de Curto-Circuito Simtrico e Poder de Corte dos Aparelhos de Proteco

Rede
Scc (MVA)
C
Un BT (V)
Zrede ()
R ()
X ()

Transformador
Sn (kVA)
630
cc (%)
4
Un BT (V)
400
Ztransf ()
1.02E-02
R ()
0.00E+00
X ()
1.02E-02

500
1.1
400
3.52E-04
0.00E+00
3.52E-04

4. Verificao das Correntes de Curto-Circuito Simtrico e Poder de Corte dos Aparelhos de Proteco para os Quadros Elctricos
Designao do circuito
Q_UPS_P1
Q_UPS_P0
Q_SERV_ADM_P1
Q_SERV_ADM_P0
Q_ENTRADA
Q_GERADOR
QPT

Quadro UPS Piso 1


Quadro UPS Piso 0
Quadro Servios Administrativos Piso 1
Quadro Servios Administrativos Piso 0
Quadro Entrada
Quadro Gerador
Quadro do PT

S (kVA)

Tenso
(V)

In (A)

9.19
16.36
17.02
51.73
630.00
630.00
630.00

400.00
400.00
400.00
400.00
400.00
400.00
400.00

13.26
23.62
24.57
74.67
909.33
909.33
909.33

Cabo a utilizar (mm2)


A05VV-U 5G4
A05VV-U 5G6
A05VV-U 5G6
A05VV-R 5G35
4x(H07XV 3x120 + N)
4x(H07XV 3x120 + N)
4x(H07XV 3x120 + N)

Caractersticas do cabo
Sf (mm)
R20C (/km)
4
0
6
3.08
6
3.08
35
0.524
120
0.153
120
0.153
120
0.153

(mH/km)
0
0
0
0.24
0.22
0.22
0.22

()

L (m)

R30C

3.00
2.82
3.00
47.89
6.50
15.00
0.00

0.00E+00
4.51E-03
4.80E-03
1.30E-02
1.29E-04
2.98E-04
0.00E+00

Nota:
Regras para a verificao da proteco contra curtos-circuitos

A intensidade nominal dos aparelhos de proteco contra curtos-circuitos deve de ser determinada de modo que a corrente de curto-circuito seja cortada antes da canalizao poder atingir a sua temperatura limite admissvel
Apenas se poder considerar que o aparelho de proteco contra curtos-circuitos se encontra adequadamente dimensionado, se satisfazer em simultneo a regra do poder de corte
Sendo a proteco efectuada por um disjuntor, a regra do tempo de corte corresponde aplicao da seguinte expresso IM Iccmn
A condio de arranque do motor corresponde garantia de no existncia de disparos intempestivos aquando da tentativa de arranque do respectivo motor (Ia IM Icc mn)
A verificao da segunda condio de proteco contra curtos-circuitos (regra do poder de corte), considerar-se- satisfeita se se demostrar verificada a seguinte expresso I ccmx IPC

x ()

Zeq ()

Icc mx (kA)

0.00E+00
0.00E+00
0.00E+00
1.81E-03
1.12E-04
2.59E-04
0.00E+00

2.20E-02
2.20E-02
2.22E-02
1.85E-02
1.09E-02
1.08E-02
1.05E-02

10.49
10.49
10.38
12.48
21.21
21.43
21.97

Poder de corte
IPC (kA)
15
15
15
15
25
25
25

Condio de verificao
Iccmx IPC
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica

Anexo 15 - Dimensionamento dos Barramentos

Rede

Transformador

Caracterstica do cobre

Scc (MVA)

500

Sn (kVA)

630

1.1

cc (%)

Un BT (V)

400

Un BT (V)

400

Ts (daN/cm2)
E (kgf/cm)

2000
1.25E+06

1. Dimensionamento do barramento de MT do Posto de Transformao

Geometria da vareta
Designao do circuito
Posto de Transformao

Scc MT (MVA)
500

UMT (kV)

Icc MT (kA)

Caractersticas da vareta de cobre no pintada

Disposio

Lmx (cm)
(1)

d (cm)
(2)

f
(daN/cm)
(3)

Mmx
(daN.cm)
(4)

Wcal (cm3)
(5)

Tipo

(mm)

s
(mm2)

W
(cm3)

I (cm )

p
(kgf/m)

Imx
(A)

Troos a evitar (cm) (6)


45-55Hz

90-110Hz

Wcal W

120

30

1.33

1200.00

0.600

Vareta

20

314.16

0.7854

0.7854

2.796

540

110-122

77-86

Verifica

f
(daN/cm)
(3)

Mmx
(daN.cm)
(4)

Wcal (cm3)
(5)

Posio da
barra

axb (mm)

2.97
2.97
2.91
4.21
12.14
12.41

74.33
74.33
72.77
105.15
303.53
310.13

0.037
0.037
0.036
0.053
0.152
0.155

Vertical
Vertical
Vertical
Vertical
Vertical
Vertical

20x5
40x5
30x5
40x5
40x5
40x5

15

19.25

Horizontal

In (A)
(Proteco)

Icc mx
(kA)

Disposio

16
30
25
80
1000
1000

10.49
10.49
10.38
12.48
21.21
21.43

Vertical
Vertical
Vertical
Vertical
Vertical
Vertical

Condio de verificao

3. Dimensionamento dos Barramentos dos Quadros

Designao do Circuito
Q_UPS_P1
Q_UPS_P0
Q_SERV_ADM_P1
Q_SERV_ADM_P0
Q_ENTRADA
Q_GERADOR

Quadro UPS Piso 1


Quadro UPS Piso 0
Quadro Servios Administrativos Piso 1
Quadro Servios Administrativos Piso 0
Quadro Entrada
Quadro Gerador

Geometria do barramento
Lmx (cm)
d (cm)
(1)
(2)
20
20
20
20
20
20

4
4
4
4
4
4

s
(mm2)
100
100
100
100
100
100

Caractersticas da barra de cobre no pintada


W
I
p
Imx
(kgf/m)
(A)
(cm3)
(cm4)
0.083
0.167
0.125
0.167
0.167
0.167

0.0208
0.0417
0.0313
0.0417
0.0417
0.0417

Nota:
1) Lmx - distncia mxima entre apoios
2) d - distncia entre barras
3) f - Fora mxima resultante dos esforos electrodinmicos
4) Mmx - Momento flector mximo
5) Wcal - Momento resistente
6) Troos a evitar so os intervalos proibidos para que o barramento no fique sujeito a fenmenos de ressonncia, entre a frequncia de vibrao prpria e a frequncia dos termos variveis que constituem as foras electrodinmicas entre as barras (50Hz e

0.882
1.770
1.330
1.770
1.770
1.770

295
520
400
520
520
520

Troos a evitar (cm) (6)


45-55Hz
90-110Hz
60-66
42-47
60-66
42-47
60-66
42-47
60-66
42-47
60-66
42-47
60-66
42-47

Condies de verificao
Wcal W
Verifica
Verifica
Verifica
Verifica
Verifica
Verifica

In Imx
Verifica
Verifica
Verifica
Verifica
No Verifica
No Verifica

TERMO DE RESPONSABILIDADE
PELA
ELABORAO DO PROJECTO

Eu, abaixo assinado


(1) Ricardo Pedro Figueira da Silva & Ana Margarida Silva Santos
categoria profissional

Engenheiros Electrotcnicos

inscrito na Direco-Geral de Energia e Geologia com o n

9999 /8888

portador do bilhete de identidade n 13839591/12096472

, passado pelo servio do

Arquivo de Identificao de Leiria

, em
20/12/2002 & 28/02/2004

domicialiado em Rua dos Anjos - Leiria


autor do projecto do

tipo B relativo a um Posto de Transformao

de 630kVA - 15/0,4kV e instalao elctrica de utilizao de uma Unidade de


Produo de Filme e Manga de Plstico pertencente ESTG Leiria,
declaro que nele se observaram as disposies regulamentares em vigor, bem
como outra legislao aplicvel.
Declaro tambm que esta minha responsabilidade terminar com a provao do
projecto ou dois anos aps a sua entrega ao proprietrio da instalao, caso o
projecto no seja submetido a aprovao.
Leiria , 09 de

Janeiro

Assinaturas

Ana Margarida Silva Santos


Ricardo Pedro Figueira da Silva

(1) Nome

Modelo EE/500

de

2013

FICHA DE IDENTIFICAO DO PROJECTO DA INSTALAO ELCTRICA


Ref.
Cmara Municipal d
Distribuidor:

Data de entrada

e Leiria
Leiria

EDP ESTG

Servios externos da DGEG:


Direco-Geral dos Espectculos:

1 - Requerente:
1.1 - Nome:

E.S.T.G. - Escola Superior de Tecnologia e Gesto de Leiria

1.2 - Morada: Morro do Lena - Alto Vieiro 2400 Leiria

2 - Instalao:
2.1 - Local:

Avenida da Boavista

2.2 - Freguesia:

Carvalho

2.3 - Concelho:

Leiria

2.4 - Categoria da instalao:


2.5 - Descrio sumria:

Tipo B

Posto de transformao de 630kVA 15/0,4kV e instalao elctrica de utilizao de uma Unidade de

Produo de Filme e Manga de Plstico


3 - Tcnico responsvel pela elaborao do projecto:
3.1 - Nome:
3.2 - Morada:

Ana Margarida Silva Santos e Ricardo Pedro Figueira da Silva


Rua dos Anjos - Leiria
Tel.

3.3 - Nmero de inscrio na DGEG:

9999/8888

4 - Tramitao do processo:
4.1 - Distribuidor de energia elctrica:

EDP ESTG

4.2 - Servios externos da Direco Geral de Energia e Geologia:


4.3 - Direco-Geral dos Espectculos:
4.4 - Cmara Municipal de

Torres Novas

ELCTRICA
Data de entrada

ao de uma Unidade de

FICHA ELECTROTCNICA

(1)

Concelho

Leiria

Instalaes novas

Lugar

Avenida da Boavista

Instalaes existentes

Localizao

Carvalho

Requerente

E.S.T.G. - Escola Superior de Tecnologia e Gesto de Leiria

Morada

Morro do Lena - Alto Vieiro 2400 Leiria

Tipo das instalaes


Portinhola

(2)

Nmero da licena municipal


Q. colunas

(2)

cx. forte

cx. barr.

Constituio do imvel

Pisos

cx. prot.

Motores e aparelhos de soldaduras

Quantidade

Nmero
de
instalaes

Unidade Fabril
de Prod. Filme
e Manga
Plstica

----

----

Total
de
instalaes

Destino

Quantidade

Potncia
(kVA)

Tipo
de
arranque

Potncia
total
(kVA)

(3)

Observaes

Cave(s)..............

Rs-do-cho......

Andares.............
Totais ...

Potncias previstas (4)


Locais de utilizao

Quantidade

Iluminao,
usos gerais
e
fora motriz
---

Aquecimento
--kVA
(5)

Instalaes sem projecto

Total
instalado
--kVA

Potncia
a
alimentar
--kVA

Coeficiente
de
simultaneidade

Habitaes .....

Unidade Fabril
PT 630kVA
15/0,4kV
Serv. comuns...
Totais ...

630

----

630

----

630

Tcnico responsvel inscrito na DGEG, sob o n


Nome (legvel) :

630

----

630

Tipo de condutores
Seco
Prot. mecnica

mm

Tipo de condutores
Seco
Prot. mecnica

mm2

circ. a 1,5 mm c/ prot.


circ. a 2,5 mm2 c/ prot.
circ. a
mm2 c/ prot.

9999/8888

Ana Sousa & Ricardo Silva

Morada (legvel) : Rua dos Anjos - Leiria

Assinatura :
(1) Uma por cada ramal, chegada ou entrada.
(2) A preencher s quando se tratar de instalaes existentes.
(3) A preencher s quando se tratar de instalaes de FM; nos aparelhos
de soldadura indicar em observaes se esttico ou rotativo.
(4) Utilizar os escales de potncia fixados no tarifrio em vigor.
(5) Um contador separado.
(6) Utilizar para estabelecimentos comerciais, industriais, agrcolas, etc.

09 /

01 / 2013

(Reservado ao visto do distribuidor)

A
A
A

You might also like