Bridge girder 202 where the truss panel (design zone) starts, b w = 7 in., z = 43 in., and 0'= 41. Degrees (see Table 4.14. Design of transverse reinforcement 4. Evaluation of the amount of web reinforcement required to resist the factored shear force.
Original Description:
Original Title
Proposed Design Procedures for Shear and Torsion in Reinforced and Prestressed Concrete Ramirez_part55
Bridge girder 202 where the truss panel (design zone) starts, b w = 7 in., z = 43 in., and 0'= 41. Degrees (see Table 4.14. Design of transverse reinforcement 4. Evaluation of the amount of web reinforcement required to resist the factored shear force.
Bridge girder 202 where the truss panel (design zone) starts, b w = 7 in., z = 43 in., and 0'= 41. Degrees (see Table 4.14. Design of transverse reinforcement 4. Evaluation of the amount of web reinforcement required to resist the factored shear force.
Distance from the centerline of the 0'-0" 4'-0" 8'-0" 12'-0" 16 '-0" support Service Total D.L. 0.0 89 158 208 239 Loads Mse LL + I 0.0 125 206 251 256 ( ft-k) Vse Total D. L. 24.5 19.7 15 10 5.3 I1 ~ ) 30 30 30 30 30 (kips) LL + I 36.8 31.3 25.8 20.9 16 Factored 1.3 [0 + 5/3 Loads (L + I)] 0.0 387 652 814 865 Mu ( ft-k) Vu 1. 3 [0 + 5/3 (L + I)] 112 93 75 58 42 (kips) Table 4.13 Calculated moments and shears for bridge girder 202 where the truss panel (design zone) starts, b w = 7 in., z = 43 in., and 0'= 41.8 degrees (see Table 4.14). 4. Design of transverse reinforcement 4.1 Evaluation of the concrete contribution in accordance with Sections 1.3.6b and 1.3.6e of Section 3.1. Additional concrete contribution to the shear capacity but where v u v =-- u b z w K = [1 + (f 12 Jfi ) p. 5 ps c with 1.0 < K < 2.0 and fps = Fse/Ab = Effective prestress force after losses/Area of the beam, but K = 1.0 if the stresses in the extreme tension fiber due to the computed ultimate load and the appl ied effecti ve pre stress force exceeds the val ue of 6 JfJ (see Fig. 4.14 and Table 4.15). 4.2 Evaluation of the amount of web reinforcement required to resist the factored shear force. A v -= s {[(V - w z cota)/] - V u u c V } tana p zf y where Av/s is the area of stirrups resisting the factored shear force per inch of the stirrup spacing "s" in each of the Design Zones Di stance from support centerline Vn = V u / (kips) fd (Eq. 4.41) (ksi) 1-2 2-3 0'-0" 4'-0" 132 109 0.90 0.10 3-4 4-5 5-6 8'-0" 12'-0" 16' -0" 88 68 49 0.60 0.50 0.30 Table 4.14 Evaluation of the compression stresses in the diagonal members of the truss 203 204 Design Support 2 3 4 5 Section Centerline Distance from the support 0'-0" 4'_0" 8'-on 12'-0" 16'-0" centerline (ft) Design Zone 1-2 2-3 3-4 4-5 5-6 fps (psi) 470 470 470 470 470 k (actual) 2.08 2.08 2.08 2.08 2.08 Stress in the -1.12 -0.18 0.45 0.84 0.85 extreme tension com- com- fiber (ksi) pression pression tension tension tension k design 2.0 2.0 1.0 1.0 1.0 Vu (ksi) 0.37 0.31 0.25 0.19 0.14 * 2 f'c (kSl) 0.57 0.57 0.42 0.42 0.42 Vp (kips) 2 2 2 2 0 Vc (kips) 60 78 26 35 42 Table 4.15 Evaluation of the additional concrete contribution to the shear strength of the member