S O L U T I O N S MV and HV connectors HV metering units LV transformer cabinets Package substations LV distribution pillars LV substation fuseboards Multi service pillars Multi service distribution boards Heavy duty cutouts Domestic service cutouts Street lighting cutouts ABC service boxes Connector boxes Fuse links Weatherproof housings MV and HV disconnectors Automation solutions Pole mounting cutouts A division of W. Lucy & Co Ltd MV ring main units RX - t he st at e of t he ar t i n ai r break t echnol ogy Air break Isolators 400/630/800A Load-break Switches 400/630A Fault Make Switches to 31.5kA Robust and highly reliable contacts capable of withstanding short time currents of up to 25kA for 3s (62.5kA peak) Independent Manual Operation Single and Double acting Spring Actuators Voltage and Current monitoring Automatic sectionalising capability Full automation capability Accessories REMOTE CONTROL (GEMI NI RTU) MOTOR ACTUATOR EARTH BLADES LOAD-BREAKI NG HEADS FAULT MAKI NG HEADS AUTOMATI C SECTI ONALI SI NG FAULT PASSAGE SENSOR UNI VERSAL BASE FOR HORI ZONTAL OR VERTI CAL MOUNTI NG PADLOCKI NG FACI LI TI ES Features RATI NGS UP TO 52k V ENVI RONMENTALLY FRI ENDLY AI R BREAK TECHNOLOGY ROBUST AND RELI ABLE VERY LOW MAI NTENANCE EASE OF I NSTALLATI ON REPLACEABLE UNI VERSAL CONTACTS ON-SI TE UPGRADES I NTERLOCKED FOR SAFE OPERATI ON Our RX air break switch has been carefully designed and developed with flexibility in mind to meet the most diverse of customers requirements. Combining high performance and high reliability, our new RX rocking type switch can be a key element of your rural distribution applications. RX - Robust and Rel i abl e wi t h added f l exi bi l i t y Robustness and reliability: Particular attention has been taken to ensure our air break switch is robust and fully reliable. A high proportion of RX components are manufactured from stainless steel for maximum protection against corrosion. The contacts have been enhanced to enable them to withstand short time currents of up to 25kA for 3s. Unlike traditional air break switches our RX range can be supplied with tungsten tipped Fault Make Heads, ensuring that switches can withstand high fault making currents up to 31.5kA. Laminated flexible connections, supported by spring steel strips, have a life span far in excess of the standard 1000 cycle test without showing signs of stress or fracture. The Arc Chute design has been improved for rapid arc extinction when load breaking. As an additional assurance of reliability, our Load Break Heads are fully tested to IEC 60265-1 by KEMA laboratory and have passed temperature rise and ice tests to IEC 60129, which make the RX suitable for the most extreme climates and conditions (coastal areas, high pollution, humidity). Flexibility Based on the concept of modular design, our RX can be configured to suit a variety of applications. From the standard switch, the RX can be very easily upgraded to meet your highest specifications and suit the evolving requirements of your network. Additional parts required for upgrade are easily fitted on locating pins ensuring correct positioning and accurate alignment without the need for any specific setting. The standard RX contacts and connector pads have been tested to 800A, 25kA/3secs. This means by adding extra laminations, the switch can be upgraded to suit specific requirements. The RX can be fitted with Fault Make Heads, Load Break Heads, or Earth Blades. The new folded universal base allows the standard switch to be mounted horizontally or vertically on most structures. The RX can be manually operated or remotely controlled via an RTU and integrated motorised actuator. It can be used as a single point of isolation or configured as an RX-S sectionaliser programmed to automatically open in the deadtime of an upstream autorecloser. A wide range of insulators is also available including ceramic or polymeric options including EPDM, Cyclo-Aliphatic or Silicone Rubber. RX - a cost ef f ect i ve sol ut i on f or your di st ri but i on net work Simplicity Significant cost savings have been achieved through the simplified design of the Load Break Heads and commonality of main RX components. One standard contact system is now available across our full range, independent of the voltage and current ratings. That enables customers to minimise stock holdings of spares. The retrofit ability of main RX components is also of prime importance. Both male and female contacts can be easily replaced on site without affecting the setting of the switch by means of accurate locating pins. The same applies to the arc chute and fault- make tips. Working in partnership with our customers has also provided real benefits. The result is a simplified and universal steelwork to suit all mounting configurations for 12, 24 and 36kV switches. This means simpler materials management, lower stock holding requirements, a greater ease of installation for the customer and improved delivery times. Based around flexibility and retrofit ability, considerable economies in terms of material, engineering and installation can be offered. All of which makes the RX a cost -effective solution for your existing network and its future expansion. RX-RC a f ul l y i nt egrat ed package f or your aut omat i on di st ri but i on needs By combining our experience in air break technology and system automation, we can offer our customers an intelligent switch optimised for remote control and monitoring. The integration of sensors (Current, Voltage and Fault Passage Indicators) provides essential information to a customers SCADA systems enabling the operator to localise, determine the cause and therefore the appropriate action to a fault on their distribution networks. Remote control and monitoring for rapid fault localisation and isolation of the faulty section. Real time information and remote switching enables the restoration of electricity supplies to the healthy parts of the network thereby improving quality of supply. Remote controlled RX switch VT for power supply to controller Hook stick manual override RTU controller Secondary automation scheme for control of automated air break switches Primary substation SCADA control system Communication via low power radio, GSM and Paknet Protocol - DNP V30 Antenna Double acting spring mechanism Insulating Insert GEMINI RTU controller features STAI NLESS STEEL ENCLOSURE FOR LONG TROUBLE FREE LI FE COMPACTNESS EASE OF FI ELD SERVI CEABI LI TY: ALL ELECTRONI CS CONTAI NED I N AN I NNER COVER CAN BE SI MPLY AND RAPI DLY REMOVED FROM THE CONTROLLER UNI T FOR MAI NTENANCE OR UPGRADE TOLERANT OF TROPI CAL ENVI RONMENTS RX General Arrangement Dimensions and installation arrangements 600 210 400 GEMINI RTU Features LOCAL / REMOTE OPERATI ON FLEXI BLE COMMS I NTERFACE - RADI O, RS232, PAKNET, GSM, PSTN, OPTI CAL FI BRE DNP3.0 PROTOCOL AS STANDARD - OTHER PROTOCOLS ON REQUEST 3 PHASE MONI TORI NG OF I NPUT VOLTAGE AND CURRENT USI NG ANALOGUE I NPUTS I SOLATED DI GI TAL I NPUTS DI GI TAL CONTROL OUTPUTS 24V BATTERY FOR CONTI NUED OPERATI ON UNDER POWER FAI LURE CONDI TI ONS BATTERY CONDI TI ON MONI TORI NG A B C D E F Rated Impulse Post Post Terminal Isolating Minimum Post Base Mounting Operating Voltage Withstand Centres Centres Pad Height Distance Phase Centres Fixing Height Mechanism kV Test Minimum Centres Centres Height 12kV 125kV 310 310 275* 242 500 290 As reqd As reqd 1200 24kV 140kV 355 355 350* 290 600 360 As reqd As reqd 1200 36kV 200kV 415 375 425* 391 700 560 As reqd As reqd 1200 52kV 250kV 500 450 600* 505 800 640 As reqd As reqd 1200 Dim D Dim A Dim B Dim C Dim F Dim C Dim E Dim E * Nominal values depending on insulator used Rapi er RX El ect ri cal Per f ormance All products have been fully certified in accordance with IEC standards: IEC 60694 (1996), IEC 60265 (1998) to meet and exceed customer specifications. * With optional Fault Make Head fitted RX-M Manual Operation Manually operated air break switch disconnector. Optional accessories include single or double-acting spring mechanism for independent manual operation. RX-RC Remote Control Remotely controlled/monitored air break switch equipped with Gemini RTU controller. Optional accessories include voltage sensing insulators and patented fault passage indicator. RX-FS Fuse Switch Fuse switch consisting of an in-series manually operated air break switch disconnector with expulsion type fuses. RX-S Sectionaliser Automatic air break sectionaliser equipped with control electronics, low voltage solenoid operated spring-assisted mechanism with manual reset, voltage sensing insulator and patented fault passage indicator. Telemonitoring optional. Product Designation Mode Description Product Range Product Range Rapier RX Rated Voltage 12kV 24kV 36kV 52kV Rated Current 400/630A 400/630A 400/630/800A 400/630/800A Power Frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz Short Time Current 25kA/3s 25kA/3s 25kA/3s 25kA/3s Fault make capacity* 31.5kA 25kA 20kA - Breaking Capacity Mainly Active Load 400/630A 400/630A 400A 400A Impulse withstand Voltage 125kV 140kV 250kV 250kV Insulator Creepage To 560mm To 1000mm To 1320mm To 1440mm Options FMH (Fault make Heads) LBH (Load Break Heads) EB (Earth Blades) Environmental Ambient Temperature -20+50 Humidity 0 -100% Altitude (max) Up to 1000m RAPIER RX Electrical Performance For pole mounted SF6 gas insulated switches, refer to RAPIER GX range. u ti l i ti e s uk In the UK, our major customers include: YORKSH I RE ELECTRI CI TY EA ST M I DLA N DS ELECTRI CI TY I N FRA LEC 2 4 SEVEN M A N WEB N ORTH ERN ELECTRI CI TY N ORTH ERN I RELA N D ELECTRI CI TY SCOTTI SH POWER SEEBOA RD SCOTTI SH & SOU TH ERN EN ERG Y G PU POWER e xp o r t worldwide Delivering products worldwide: CLP H o n g Ko n g M EW Ku w a i t M EW Om a n A DWEA A b u Dh a b i BEC Ba h a m a s CEA M a u r i t i u s G ECOL Li b y a ECG G h a n a KPLC Ke n y a N EPA N i g e r i a SESCO Sa r a w a k U EB U g a n d a TN B M a l a y s i a POWERG RI D Si n g a p o r e SCECO Sa u d i Power Isolators Office Unit 14 Thorpe Lane Thorpe Way Industrial Estate Banbury OX16 4UT United Kingdom telephone +44 (0)1295 270448 fax +44 (0)1295 270446 email Power.Isolators@wlucy.co.uk internet http://www.lucyswitchgear.com A global network Currently exporting to more than 50 countries. Over the past three decades LUCY Switchgear has become a truly international company with sites in the UK, the Middle East, South Africa, India and the Mediterranean. LS 00001 RX 072001