Air Cooled Chillers

1
Systemair - Via XXV Aprile, 29
TEL 0039 0362 680 - FAX 0039 0362 680791 20/05/2014 Version : 2.9.5
VLS R410A BLN 1204
GENERAL INFORMATION
These units are of a monobloc type with two refrigerating
circuits. They are suitable for cooling the water required for any
air-conditioning application as well as any other fluid, such as
for example glycol water, that may be used in industrial
processes.These units are completely assembled at works.
They are equipped with all the internal refrigerating and
electrical connections required for a rapid installation on site.
Standard Version (BLN)
These units are suitable for an outdoor installation on the
building roof rather than directly on the ground level.
FRAME AND BODY
It is made up of zinc plated steel bars and sheets. It is painted
with polyester powders and baked in the furnace (high
resistance anticorrosive treatment in presence of an
aggressive atmosphere). Its screws are made of stainless
steel.Modular realisation providing for a perfect air flow rate
and an easy access to the various components for
maintenance and repair operations.
COMPRESSORS
Scroll hermetic type. The rotor is cooled by the suction
refrigerating fluid.The compressors are fitted inside an
insulating acustic box made by sheet metal. They are
complete with:
*built-in thermistor protection
*automatically reset protection against overloads
*IP54 terminal boards
*crankcase oil heater
WATER HEAT EXCHANGER
Type with "Dual Type" stainless steel plates.Equipped with:
*antifreeze electrical heater complete with a thermostat
*external heat insulation with a closed cell mattress
*threaded water connections for the loop
*single inlet/outlet
AIR HEAT EXCHANGER
Aluminium Microchannel coils.
FANS
The fans are of a direct coupling helical type. They have a fan
wheel with wing contour aluminium blades. Each fan is
equipped with a painted zinc plated steel accident prevention
grille. The motors of the fans are completely enclosed. They
have an IP54 protection rating and a protection thermistor
inside the windings.
ELECTRIC BOARD
Built in compliance with the EN60204-2 standards and fitted in
an IP 54 proof box complete with:
*door lock main disconnector switch
*power components for the start-up of compressors and fans
CONTROL MICROPROCESSOR
Can regulate and display the parameter below:
*Water inlet Temperature
*Water Outlet Temperature
*Antifreeze
*Compressor and Fan status
*Compressors Suction and Discharge pressure
*Air Temperature
*Pump Down Logic
*Evaporating Temperature
*Superheater
*Compressor envelope
*Thermostatic Valve
*History alarms
ALARMS
The following types of alarms are available:
*high pressure
*low pressure
*antifreeze
*external interlock, flow switch
*discharge gas high temperature (heat pump and heat
recovery version only)
2
20/05/2014 Version : 2.9.5
VLS R410A BLN 1204
General technical data
Cooling Capacity kW 305.3
Input Power kW 115.6
ESEER 3.66
IPLV 3.83
EER 2.64
Number of refrigerating circuits n 2
Part load steps n 25-50-75-100
power supply V/f/Hz 400/3/50
Max input Power kW 148
Maximum running current A 268
startup current A 515
Refrigerant R410A
Compressor
Number n 4
Type Scroll
startup Type Direct
Evaporator
Number n 1
Type Plates
Chilled Fluid Water
Chilled Fluid Flow Rate l/s 14.64
Pressure drop on the chilled fluid side kPa 41.39
Chilled fluid inlet temperature C 12
chilled fluid outlet temperature C 7
Fouling factor m C/kW 0.044
water connections Type Male Gas Thread
Inlet diameter 3"
outlet diameter 3"
Fans
Number n 4
Type Axial Fans
Absorbed power per fan KW 1.9
Air flow rate m/s 21
External air temperature C 35.3
Dimensions and weights
Length mm 4300
Width mm 1100
Height mm 2300
Shipping weight kg 1815
Operating weight kg 1840
Environment
Standard Environment
Distance from Sea [km] km Not Available
Altitude m 0
NOTE: You have selected a STD environment
Check warranty conditions
All specification and data are subject to change without notice.
3
20/05/2014 Version : 2.9.5
VLS R410A BLN 1204
Sound Information
8000
Sound Data Octave Band (Hz)
63 125 250 500 1000 2000 4000
Mode
Sound Power Level dB
1204
Sound Power Level dB(A)
Normal 0 89 88 96 90 84 69 57 95
Sound Data
Sound power level dB(A) 95
Distance from the sound source m 10
Sound pressure level** dB(A) 63
**Sound pressure levels refer to ISO standard 3744 with parallelepiped shape.
4
20/05/2014 Version : 2.9.5
VLS R410A BLN 1204
Operating Limit
Zone 1: Water
Zone 2: Water and Glycol
Zone 3: Water and FSC
Zone 4: Water, Glycol and FSC
Zone 5: Brine
5
20/05/2014 Version : 2.9.5
VLS R410A BLN 1204
Refrigeration Circuit
Components:
1) Compressor Tandem Scroll Type
2) Air Cooled Condenser
3) Dehydrating filter
4) Electronic expansion valve
5) Globe valve
6) Heat exchanger (Dual Type)
7) Desuperheathers (optional)
Safety and Control Devices:
A) High pressure switch
AT) High pressure transducer
BT) Low pressure transducer
C) Water differential pressure switch
D) Air temperature sensor
E) Water outlet temperature sensor
F) Water intlet temperature sensor
G) PED pressure relief valve
6
20/05/2014 Version : 2.9.5
VLS R410A BLN 1204
Dimensional Drawing
A = Water outlet 3"M
B = Water inlet (with a pump) 3"M
C = Water inlet (without a pump) 3"M
D = Only with two pumps
E = 1985 mm (Lifting Point)
F = 1179 mm (Lifting Point)
L = 720 mm
7
20/05/2014 Version : 2.9.5
VLS R410A BLN 1204
Space requirements
A = 1500mm
B = 1000mm
C = 1500mm
D = 1500mm
E = 3000mm
F = Air flow
8
20/05/2014 Version : 2.9.5
VLS R410A BLN 1204
Electrical connections
A = On/Off remote control
B = Cooling/Heating remote selection (Heat Pump only)
C = Flow switch or external interlock
D = External safety switch (optional)
E = Remote system control 1 (only VLC)
F = Remote system control 2 (only VLC)
G = Voltage presence remote indication
H = Circuit 1 general alarm remote indication
I = Circuit 2 general alarm remote indication
J = Compressor 1 remote indication
K = Compressor 2 remote indication
L = Compressor 3 remote indication
M = Compressor 4 remote indication
N = Antifreeze hydrokit relay max 0.5A at 230V
O = Pump hydrokit relay max 0.5A at 230V
Note: always refer to the diagram aboard the unit
9
20/05/2014 Version : 2.9.5
VLS R410A BLN 1204
Weights Distribution
Weights Distribution (kg)
462
P1
367
P2
409
P3
302
P4
344
P5
249
P6
Distance between the supports (mm)
1044
A
1985
B
1629
C
Shipping Weight (kg)
Operating Weight (kg)
1815
1840