Unity Pro XL Learning


Schneider Electric Thailand
Automation Solution
2
Choose Unity Pro XL
3
Program active
4
Create new PLC program
5
Choose PLC type
6
Project creating
7
Choose Hardware config (double click)
8
Existing PLC with blank I/O
9
Double click slot No. 1
10
Choose 16 Input module
11
Choose another slot
12
Choose 16 Output module
13
Click to close Hardware catalog
14
Start MAST task (click)
15
Select section
16
Right click to create new section
17
Choose LD ( Ladder )
18
Apply section name
19
Click OK
20
New section programming area
21
Click to close PLC bus
22
Click to close Project Browser
23
Click to enlarge Programming area
24
Ready to programming
25
Choose NO contact ---| |---
26
Click to place contact on any location
27
Choose NC contact ---|/|---
28
Choose Output ---( )---
29
Place on any location in 1
st
row
30
Choose vertical line
31
Connect vertical line
32
Change mouse back to pointer
33
Double click to assign tag
34
Assigned Start tag
35
Choose BOOL
36
Accept change
37
Assign Stop tag
38
Assign Relay tag
39
Double click to assign tag
40
Choose existing tag
41
Choose Relay tag
42
OK to confirm
43
Analyze project
44
Analyze report
45
Rebuild project
46
Rebuild report
47
Connect to PLC
Simulation Mode
48
PLC status program difference
49
Download program
50
Transfer confirm
51
Transferring
52
Transfer complete
53
Place PLC in RUN
54
PLC RUN Confirm
55
PLC RUN
56
Right click on Start bit set 1
57
Start bit active
58
Right click on Start bit set 0
59
Start bit OFF
60
Right click on Stop bit set 1
61
Stop bit active
62
Bit status monitor (drag mouse cover monitor bits)
63
Bit monitoring showing up
64
Right click then choose Table
65
Animation table show bit status
66
Show multiple windows
67
Monitor both Ladder & Table
68
Choose Modification
69
Right click on modify bit, set to 0
70
Stop bit Inactive
71
Select Start bit and set value to 1
72
Start bit Active->Relay bit
73
Reset Start bit
74
Start bit Inactive but Relay still Active
75
Set Stop bit
76
Stop bit Active->Relay bit Inactive
77
Reset Stop bit
78
Stop bit Inactive
79
Open Project Browser to create Operator screen
80
Right click to create new screen
81
Apply screen name and click ok
82
Screen area
83
Choose Push Button
84
Place on location
85
Select and right click to Copy Button
86
Right click and paste
87
Drag to desired location
88
Choose Text
89
Place on location
90
Copy text
91
Paste
92
Text Done
93
Double click to config button
94
Choose tag and ok
95
Tag assign done
96
Assign another tag
97
OK
98
Config text with Relay ON
99
Choose REDcolor
100
Choose animated object
101
Choose Relay tag
102
Show when bit = 1
103
Choose Standard display
104
Config Text 2 with Relay OFF
105
Choose Green
106
Choose animated object
107
Choose Relay tag
108
Show when bit = 0
109
Choose Standard display
110
Rearrange screen
111
Add 1
st
Button label
112
Add 2
nd
Button label
113
Operator screen ready to test
114
Start graphic monitor
115
Press Start
116
Relay ON
117
Press Stop
118
Relay OFF
119
Save work
120
Enter file name
121
Finish saving
122
Exit program
123
Confirm to exit
124
Thank you