You are on page 1of 3

For booking enquiries please email Ali Coles at

ali.coles@exida.com or call the ofce on +(0)1926 676125


Course Overview
The exSILentia integrated Safety Lifecycle Engineering Tool is a powerful
aid for any engineer involved in safety lifecycle tasks such as SIL
selection, Safety Requirements Specification, and SIL verification. Users
who are new to functional safety engineering or would like hands-on
training for a quick start up, exida has developed a two-day course. This
course will familiarize users with all facets of the exSILentia tool to ensure
efficient implementation of the Safety Lifecycle tasks.

Skills You Will Learn:
How to perform Safety Integrity Level (SIL) Selection and Verification
using the advanced capabilities of exSILentia
Determine the required risk reduction for each hazard scenario and
the achieved risk reduction for each identified Safety Instrumented
Function (SIF)
Understand interfacing with Process Hazard Analysis results
Understand the documentation of the Safety Requirements
Specification (SRS)
Understand operational aspects such as proof testing
SIL Selection and SIL Verification
with exSILentia


For booking enquiries please email Ali Coles at
ali.coles@exida.com or call the ofce on +(0)1926 676125
Section 1 : exSILentia Introduction
Safety Lifecycle Tool
exSILentia Tool Options

Section 2 : Projects / Safety Instrumented Functions
Defining Hazard Scenarios / Safety Instrumented Functions
Navigating projects

Section 3 : Project Resources
Project Dashboard
Reference Library
Team Members
Action Item Recording
Tool status

Section 4 : Tolerable Risk Specification
Calibrating Risk Graph/Hazard Matrix
Calibrating Frequency Based Target Options (LOPA)

Section 5 : Specify Required Risk Reduction/SIL Selection
SIL Selection Methods
Independent Layers of Protection
Critical Device List

Section 6 : Specifying Safety Requirements using SIF SRS

Section 7 : Creating and verifying conceptual designs using exSILentia
SILver
Working with groups
Specifying Equipment
Determining Achieved SIL
Discuss typical SIL verification parameters
MooN Voting Architecture
SIL Selection and SIL Verification
with exSILentia


For booking enquiries please email Ali Coles at
ali.coles@exida.com or call the ofce on +(0)1926 676125
Section 8 : Safety Equipment Reliability Handbook

Section 9 : Generating reports
SIF list
SILver Summary
IEC 61511 Compliance Report (Analysis Report)
Proven In Use Justification
Optional Reports

Section 10 : Software and Equipment Data Updates

Section 11 : exSILentia Optional Functionality overview only
PHAX
PHA Import
Lifecycle Cost Estimator
Proof Test Report Generator
SRS
C&E
, System SRS with C&E Matrix
SILAlarm
Customer Proprietary Equipment Database

Section 11 : exSILentia Support Utilities

Section 12 : Third Party Tool Interfaces

Section 13 : Examples
Complete exSILentia SLC example
Complex (?) SIL verifications
Conceptual Design SIL verification Exercise

SIL Selection and SIL Verification
with exSILentia

You might also like