You are on page 1of 15

BUILDING SPACE PROGRAM

No. of
Units
No. of
Users
Area per
Person
(in m
2
)
Total
Area
(in m
2
)
Location & Remarks* *those
marked 2/F are on the 2nd Floor, all others are on the
ground floor
SPACE REQUIRED
A. PASSENGER TERMINAL BUILDING 2,694.6 (building footprint)
1. Public Lobby 392.6 between Departure Entrance & Arrival Exit
Information w/ Flight Schedule Board 1 4 1.5 8.0 conspicuous location in open space
Waiting Area (Seated) 1 75 0.7 35.0 center of public lobby, wide seats w/ luggage space
Well-Wishers Area 1 30 0.65 19.5 departure side
Greeters Area 1 30 0.65 19.5 arrival side
Airline Ticketing Offices 3 3 2.5 22.5 attached to building
Waiting Area 3 20 0.65 42.0 includes aisle
Consessions (Sales, Storage, & Seating)
Snack Bar/Coffee Shops 3 3 2.5 22.5 sales counter, prep area, display & storage
Pasalubong Shops 2 3 2 12.0 sales counter, display & storage
Tables & Chairs 10 4 1.5 60.0 shared by concessionaires
ATM Booths 2 1 2 4.0 includes queuing area
Payphones 2 1 1.5 3.0 includes queuing area
Restrooms Male 1 6 1.65 9.9 2 WC, 4 urinals, 3 lavatories
Female 1 7 1.65 11.6 7 WC, 3 lav
PWD 1 1 3.1 3.1 1.7 x 1.8 minimum dimensions
Water Feature 1 1 28 40.0 approx. 10% of public lobby
Pocket Gardens 4 1 7 40.0 approx. 10% of public lobby
Circulation Paths 1 1 28 40.0 approx. 10% of public lobby
2. Departure Area 1,675.2 mostly natural ventilation
Baggage Trolley Parking 1 1 16 16.0 1 x 0.7 trolley; 2 stacks of 20 (+0.4 per trolley)
Curbside Queuing 2 20 1.6 64.0 one area each per entrance (spare)
Terminal Entrance 2 1 4 8.0 one regular, one spare (open only during peak)
Passenger & Baggage Screening 1 1 110.25 110.3 3 units metal detector, 2 units xray, plus clearances
Passenger Lobby (seated) 1 40 0.7 28.0 wider seats w/ space for luggage
Pass-through area 1 1 25 25.0 2.5m x 10m (length of counter)
Queuing for Check-in 4 20 1.6 128.0 max of 4 lines, 20 pax during peak
Self-Service Check-in 2 1 1.5 3.0 for future, includes queuing
A Domestic Airport for Roxas City | 1 of 15
BUILDING SPACE PROGRAM
392.6
88.0
314.3
A Domestic Airport for Roxas City | 2 of 15
BUILDING SPACE PROGRAM
No. of
Units
No. of
Users
Area per
Person
(in m
2
)
Total
Area
(in m
2
)
Location & Remarks* *those
marked 2/F are on the 2nd Floor, all others are on the
ground floor
SPACE REQUIRED
Check-in Counters 4 2 2.5 20.0 2 regular, 2 spare (for express, during peak)
Baggage Conveyor 1 1 20 20.0 behind counter
Support Offices 3 4 2.5 30.0 for CAAP, or airline crew
Outbound Baggage Room 1 1 90 90.0 can handle 2 simultaneous flights
Terminal Fee Booths 2 1 2.5 5.0 includes queuing area
Circulation
Hallways 1 1 20.0 20.0 approx. 10% of passenger lobby
Escalator 1 1 19 19.0 based on Otis Link specifications, 1m-width
Elevator 1 1 6.85 6.9 based on Otis Hydrofit 15 pax hydraulic elevator
Stairs 1 1 14.4 14.4 1.5 m width, 0.174 rise, 23 steps, U-type
Payphones 2 1 1.5 3.0 includes queuing area
Restrooms Male 1 4 1.65 6.6 1 WC, 3 urinals, 2 lavatories
Female 1 5 1.65 8.3 5 WC, 3 lav
PWD 1 1 3.1 3.1 1.7 x 1.8 minimum dimensions
Janitor's Closet 1 1 2 2.0 0.75 x 2 m
Pre-departure Screening 2/F
Queuing Area 2 25 1.4 70.0 2/F, peak at 25 pax per queue
Hand-carry X-ray Station 1 1 70 70.0 1 xray machine, 2 metal detectors, clearances
Departing Lounge 1 320 0.7 224.0 2/F, artificial ventilation
Wheelchair slots 2 1 1.2 2.4 min of 1 for every 200 pax
Aisles/Circulation 1 1 45 45.0 approx 20% of departing lounge
Laptop/Gadget Charging Area 1 6 1.4 8.4
Prayer Room 1 1 7.5 7.5 2.5 x 3
Smoking Lounge 1 10 0.7 7.0 2/F, natural ventilation
VIP/CIP Room 1 10 1.4 14.0 2/F, artificial ventilation
Restrooms - Male 1 2 1.65 3.3 1 WC, 1 urinal, 2 lavatories
- Female 1 2 1.65 3.3 2 WC, 2 lavatories
Mabuhay Lounge (PAL Bsns Class) 1 10 1.4 14.0 2/F, artificial ventilation
Contingency Lounge 1 40 2 80.0 for delayed flights, extra pax during peak season
9
5
2
.
3
A Domestic Airport for Roxas City | 3 of 15
BUILDING SPACE PROGRAM
314.3
140.0
63.3
20.0
140.0
722.7
A Domestic Airport for Roxas City | 4 of 15
BUILDING SPACE PROGRAM
No. of
Units
No. of
Users
Area per
Person
(in m
2
)
Total
Area
(in m
2
)
Location & Remarks* *those
marked 2/F are on the 2nd Floor, all others are on the
ground floor
SPACE REQUIRED
Concessions 182.0 2/F, artificial ventilation
Coffee Shops 2 1 24 48.0 inclusive of 10 seats for dining
Snack Bars/Restaurants 2 1 24 48.0 inclusive of 10 seats for dining
Pasalubong/Gift Shops 2 1 15 30.0
Newstand 1 1 10 10.0
Telecom booth 1 1 10 10.0
Service Corridor 1 1 36 36.0
Restrooms Male 1 5 1.65 8.3 2/F, 2 WC, 3 urinals, 3 lavatories
Female 1 7 1.65 11.6 7 WC, 4 lavatories
Enplaning Gates 2 1 3 6.0 2/F, inclusive of airline security check
Queuing Area 2 40 0.65 52.0 2/F, 2 lines per gate; 20 pax per queue
Boarding Corridor 1 1 54 54.0 2/F, 1.8 x 30 m corridor
3. Arrival Area 756.1 natural ventilation
Deplaning Gates 1 1 7.5 7.5 2/F, provide counter w/ visitors stools, sofa
Corridor 1 1 27 27.0 2/F, 1.8 x 15 m corridor
Restrooms Male 1 4 1.65 6.6 2/F, 1 WC, 3 urinal, 2 lavatories
Female 1 5 1.65 8.3 5 WC, 3 lav
Circulation
Escalator 1 1 19 19.0 based on Otis Link specifications, 1m-width
Elevator 1 1 6.85 6.9 based on Otis Hydrofit 15 pax hydraulic elevator
Stairs 1 1 14.4 14.4 1.5 m width, 0.174 rise, 23 steps, U-type
Inbound Baggage Unloading Dock 1 1 90 90.0 can handle 2 simultaneous flights
Baggage Claim w/ Conveyor System 1 1 500 500.0 2 conveyor systems; can accommodate 2 flights
Baggage Trolley Parking 1 1 60 60.0 max of 200 trolleys
Payphones 2 1 1.5 3.0 includes queuing area
Claim Stub Checking 1 1 2 2.0
Arrival Exit 1 1 4 4.0
Car Rental/Shuttle Service 3 1 1.5 4.5
Travel Agency Booths 2 1 1.5 3.0
9
5
2
.
3
A Domestic Airport for Roxas City | 5 of 15
BUILDING SPACE PROGRAM
89.6
71.5
722.7
655.0
A Domestic Airport for Roxas City | 6 of 15
BUILDING SPACE PROGRAM
No. of
Units
No. of
Users
Area per
Person
(in m
2
)
Total
Area
(in m
2
)
Location & Remarks* *those
marked 2/F are on the 2nd Floor, all others are on the
ground floor
SPACE REQUIRED
Waiting Area 1 40 1.5 60.0 extension of public lobby
4. Offices & Related Facilities 682.7 secured area
Airline Support Facilities
Flight Crew Lounge 1 12 1.6 19.2
Restrooms, 1 M/1F 2 2 1.7 6.8
Aircraft Cleaning Staff Room/Storage 1 1 10 10.0
Inflight Snack Prep Room 2 3 2.5 15.0
Airport Offices Reception 1 2 2.5 5.0 secured, handled by 1 or 2 receptionists
Waiting Area 1 10 0.65 6.5
Airport Director's Office 1 1 9 9.0 central to all business offices
Deputy Director 1 1 7.5 7.5
Executive Secretary 1 12 5 60.0
Restroom (M/F) 1 1 2.25 2.3 serves 3 personnel
Anteroom 1 1 6 6.0 reception area
Legal Counsel Office 1 1 7.5 7.5
Public Affairs Officer 1 1 5 5.0
Legal Affairs Clerk 1 1 2.5 2.5
Business Development Office 1 1 7.5 7.5 private office
Corporate Planning Head 1 1 5 5.0
Leasing Manager 1 1 5 5.0
Airline Relations Officer 1 1 5 5.0
Clerks 1 2 2.5 5.0
Finance Department Office 1 1 7.5 7.5
Accountant 1 1 5 5.0
Bookkeeper 1 1 5 5.0
Budget Officer 1 1 5 5.0
Accounting Clerks 1 4 2.5 10.0
Administrative Office 1 1 7.5 7.5 private office
HR Manager 1 1 5 5.0
open planning, low partitions
open planning, low partitions
1
9
2
.
1
5
located on airside, between departure & arrival
A Domestic Airport for Roxas City | 7 of 15
BUILDING SPACE PROGRAM
682.7
71.5
51.0
29.75
15.0
27.5
32.5
57.5
A Domestic Airport for Roxas City | 8 of 15
BUILDING SPACE PROGRAM
No. of
Units
No. of
Users
Area per
Person
(in m
2
)
Total
Area
(in m
2
)
Location & Remarks* *those
marked 2/F are on the 2nd Floor, all others are on the
ground floor
SPACE REQUIRED
Property Manager 1 1 5 5.0
Procurement Officer 1 1 5 5.0
Supply Officer 1 1 5 5.0
Administrative Clerks 1 6 5 30.0
Conference Room 1 20 1.4 28.0 doubles as boardroom
Management Staff Lounge w/ Pantry 1 10 2 20.0
Restrooms (M + F, 3-pax) 2 3 1.65 9.9
Operations Department Office 1 1 7.5 7.5 private office
Airfield Officer 1 1 5 5.0
Aircraft Parking Coordinator 1 1 2.5 2.5
Aircraft Servicing Specialists 1 4 2.5 10.0
Terminal Operations Administrator 1 1 5 5.0
Passenger Process Manager 1 1 5 5.0
Airline Coordinator 1 1 5 5.0
Clerks 1 4 2.5 10.0
Office of the Building Administrator 1 1 7.5 7.5 private office
Administrative Assistant 1 1 5 5.0
Housekeeping Services 1 4 2.5 10.0
Electronics & Communications Office 1 1 7.5 7.5 private office
IT Room & Server Area 1 4 2.5 10.0 enclosed, climate-controlled
PA Control Room 1 2 2.5 5.0 enclosed, accoustically-treated
Radio Control Room 1 2 2.5 5.0 enclosed, accoustically-treated
Chief of Airport Security 1 1 7.5 7.5
Deputy Chief of Airport Security 1 1 5 5.0
CCTV Monitoring Room 1 3 2.5 7.5
Security Coordinating Room 1 15 1.4 21.0 private area
Security Personnel Assembly 1 15 0.65 9.8 extension of lounge
Security Staff Lounge & Lockers 1 15 1.4 21.0 contiguous with assembly area
Restrooms - Male 1 4 1.65 6.6 2 WC, 2 urinals, 2 lavatories
open planning, low partitions
open planning, low partitions
open planning, low partitions
1
9
2
.
1
5
2
4
2
.
6
open planning, low partitions
open planning, low partitions
A Domestic Airport for Roxas City | 9 of 15
BUILDING SPACE PROGRAM
29.9
57.5
30.0
27.5
85.0
57.5
A Domestic Airport for Roxas City | 10 of 15
BUILDING SPACE PROGRAM
No. of
Units
No. of
Users
Area per
Person
(in m
2
)
Total
Area
(in m
2
)
Location & Remarks* *those
marked 2/F are on the 2nd Floor, all others are on the
ground floor
SPACE REQUIRED
- Female 1 4 1.65 6.6 4 WC, 3 lavatories
Personnel Lounge & Pantry 1 15 2 30.0
Restrooms - Male w/ Lockers 1 3 1.8 5.4 1 WC, 2 urinals, 2 lavatories
- Female w/ Lockers 1 4 1.8 7.2 4 WC, 2 lavatories
CAAP Office 1 5 5 25.0 CAAP = Civil Aviation Authority of the Philippines
Anteroom w/ Reception 1 1 2.5 2.5
Circulation for Offices 1 1 90 90.0 approx 15% of total office spaces
5. Clinic 42.1 with access to both departure & arrival areas
Waiting Area 1 5 0.65 3.3
Attending Physician 1 1 7.5 7.5 general medicine
Nurse Station 1 2 5 10.0
Examination & Recuperation Area 1 3 3.75 11.3 w/ 3 beds
Breastfeeding Station 1 5 1.4 7.0 lounge seats
Restroom (M/F) 1 1 3.1 3.1 PWD-compliant
Circulation 1 1 5 5.0 approx 10% of clinic spaces
6. Covered Sidewalk (Curbside)
Drop-off (Departure Side) 1 1 70 70.0 2.5 x 28 m (4 cars)
Pick-up (Arrival Side) 1 1 105 105.0 2.5 x 42 m (6 cars)
2
4
2
.
6
A Domestic Airport for Roxas City | 11 of 15
BUILDING SPACE PROGRAM
90.0
42.6
27.5
42.1
175.0
85.0
A Domestic Airport for Roxas City | 12 of 15
SITE SPACE PROGRAM
No. of
Units
Area per
Unit (in
m
2
)
Total Area
(in m
2
)
Location & Remarks
I. AIRPORT BUILDINGS 7,423 including future expansion
A. PASSENGER TERMINAL BUILDING 2,695
B. CARGO TERMINAL BUILDING 193
C. AIR TRAFFIC CONTROL TOWER 48
D. SITE MAINTENANCE & AIRCRAFT SERVICING 496
E. EMERGENCY RESPONSE FACILITY 291
F. AREA FOR FUTURE EXPANSIONS 3,700 approx 60% of initial dev't.
II. CURBSIDE AREA 32,472 including future expansion
A. PARKING
Departure Public Parking 120 15 1,800 1:3 pax
Arrival Public Parking 120 15 1,800 1:3 pax
Long-Term Secured (Pay) Parking 70 15 1,050 approx. 20% of departing pax
Staff Parking 70 15 1,050 1:2 staff
Shuttle Service 10 18 180
Taxi Temp Parking 20 15 300
Bus Bay 2 30 60
Government/Police/OB Vehicles 10 18 180
B. ACCESS & CIRCULATION 1 9000 9,000 15m x 600 m (estimate/not yet fixed)
C. OPEN GROUNDS/LANDSCAPING 1 6000 6,000
D. REQUIRED SETBACKS 1 1800 1,800
E. AREA FOR FUTURE EXPANSION
Parking (additional 60% of all parking spaces) 1 3852 3,852
Access & Circulation (additional 60%) 1 5400 5,400
SPACE REQUIRED
A Domestic Airport for Roxas City | 13 of 11
SITE SPACE PROGRAM
No. of
Units
Area per
Unit (in
m
2
)
Total Area
(in m
2
)
Location & Remarks SPACE REQUIRED
III. AIRSIDE AREA 471,980 including future expansion
A. RUNWAY 440,000 as per site provided
B. BACKOFF/MANUEVERING 2 2700 5,400 minimum, based on Airbus A320 aircraft
C. APRON 2 3500 7,000 based on Airbus A320 aircraft
D. GROUND SUPPORT CIRCULATION 1 4000 4,000 10m x 400 m (estimate/not yet fixed)
E. OPEN GROUNDS 1 2700 2,700
F. REQUIRED SETBACKS 1 480 480
G. AREA FOR FUTURE EXPANSION
Additional Aprons 2 3500 7,000
Backoff/Maneuvering 2 2700 5,400
TOTAL AREA (INCLUDING FUTURE EXPANSION) 511,875
TOTAL AREA OF SITE 512,000
A Domestic Airport for Roxas City | 14 of 11
SUBMITTED BY: SUBMITTED TO:
MARK G. DELFIN ARCH. VINCENT RAYMUND Y. ALOVERA
BS ARCH 4-C INSTRUCTOR
A D O M E S T I C A I R P O R T
SITE & BUILDING SPACE PROGRAM
DESIGN 8-C