Regulatory
Chapter 1 Introduction
Section 1 GENERAL INFORMATION............................................... 1-1
Section 2 EQUIPMENT LIST............................................................. 1-2
2.1 KSUs and Optional Unit.................................................................. 1-3
2.1.1 IP4[ ]-1632M-A KSU...................................................................... 1-3
2.1.2 IP4[ ]-1632ME-A EXP................................................................... 1-4
2.1.3 IP4WW-EXIFB-C1......................................................................... 1-4
2.1.4 IP4WW-Battery Box...................................................................... 1-4
2.2 Trunk/Extension/ISDN Expansion Interface Cards......................... 1-5
2.2.1 IP4WW-408E-A1........................................................................... 1-5
2.2.2 IP4WW-008E-A1........................................................................... 1-5
2.2.3 IP4WW-000E-A1........................................................................... 1-5
2.2.4 IP4WW-2BRIDB-C1...................................................................... 1-5
2.2.5 IP4WW-1PRIU-C1........................................................................ 1-6
2.3 Optional Interface Cards................................................................. 1-6
2.3.1 IP4[ ]-MEMDB-C1......................................................................... 1-6
2.3.2 IP4WW-VOIPDB-C1 .................................................................... 1-6
2.3.3 PZ-VM21....................................................................................... 1-7
2.3.4 IP4WW-CFVRS-C1/IP4WW-CFVMS-C1/IP4WW-CFVML-C1 ..... 1-7
2.4 Multiline Telephones and Optional Equipment .............................. 1-7
2.4.1 IP4WW-12TXH-A TEL.................................................................. 1-7
2.4.2 IP4WW-24TXH-A TEL.................................................................. 1-7
2.4.3 IP4[ ]-24TIXH-C TEL .................................................................... 1-8
2.4.4 IP4WW-60D DSS-A...................................................................... 1-8
2.4.5 DP-D-1D........................................................................................ 1-8
Section 3 SYSTEM CAPACITY......................................................... 1-9
3.1 System Capacity............................................................................. 1-9
3.2 KSU Capacity............................................................................... 1-10
3.2.1 Expandability of Trunk and Extension (without PRI)................... 1-12
3.2.2 Expandability of Trunk and Extension (with PRI)........................ 1-13
Chapter 2 Installation
Section 1 INSTALLING THE MAIN & EXPANSION KSUs............... 2-1
1.1 Before Installing the KSU(s)........................................................... 2-1
1.1.1 General Precautions..................................................................... 2-1
1.1.2 Preparations.................................................................................. 2-1
1.1.3 Site Requirements......................................................................... 2-1
1.1.4 Environmental Requirements........................................................ 2-2
1.1.5 Unpacking..................................................................................... 2-2
1.2 Installing the Main KSU (1632M-A KSU) ...................................... 2-2
1.3 Wall-Mounting the KSU(s).............................................................. 2-3
1.3.1 KSU Dimensions........................................................................... 2-3
1.3.2 Wall Installation of KSU................................................................. 2-4
ISSUE 4.0 SL1000
Hardware Manual i
1.3.3 Mounting Procedure of KSU......................................................... 2-6
1.4 Installing the Expansion KSU(s)..................................................... 2-9
1.4.1 General......................................................................................... 2-9
1.4.2 Unpacking (EXIFB-C1).................................................................. 2-9
1.4.3 Connectors Location (EXIFB-C1).................................................. 2-9
1.4.4 Installing the EXIFB-C1 PCB........................................................ 2-9
1.4.5 KSUs Inter-connection................................................................ 2-12
1.5 Grounding and AC Cabling........................................................... 2-12
1.5.1 Grounding the KSU..................................................................... 2-13
1.5.2 AC Power Requirement.............................................................. 2-13
1.5.3 AC Power Cord........................................................................... 2-14
1.6 Trunk/Extension Cabling............................................................... 2-14
1.6.1 General....................................................................................... 2-14
1.6.2 Precautions for Cabling............................................................... 2-15
1.6.3 Trunk Cabling.............................................................................. 2-15
1.6.4 Extension Cabling....................................................................... 2-16
1.6.5 Power Failure Transfer................................................................ 2-17
1.6.6 Cable Routing and Clamping...................................................... 2-19
Section 2 INSTALLING THE EXTERNAL BACKUP BATTERY..... 2-20
2.1 General......................................................................................... 2-20
2.2 Unpacking..................................................................................... 2-20
2.3 Battery Box Dimensions .............................................................. 2-21
2.4 Battery Specifications................................................................... 2-21
2.5 Battery Installation........................................................................ 2-21
2.6 Mounting the IP4WW-Battery Box................................................ 2-27
2.6.1 Floor-Mounting the IP4WW-Battery Box..................................... 2-27
2.6.2 Wall-Mounting the IP4WW-Battery Box...................................... 2-29
2.6.3 Mounting One KSU on the Battery Box....................................... 2-33
2.7 IP4WW-Battery Box to KSU Connection...................................... 2-36
2.8 IP4WW-Battery Box Fuse Replacement....................................... 2-37
Section 3 INSTALLING THE EXPANSION INTERFACE
CARDS......................................................................... 2-42
3.1 General......................................................................................... 2-42
3.2 Unpacking..................................................................................... 2-42
3.3 Mounting the Expansion Interface Card....................................... 2-43
3.3.1 Mounting the 408E-A1/008E-A1/000E-A1/1PRIU-C1 PCBs....... 2-43
3.3.2 Mounting the 2BRIDB PCB......................................................... 2-47
3.4 Cabling and Setting the Expansion Interface Card....................... 2-49
3.4.1 Cabling IP4WW-408E-A1............................................................ 2-50
3.4.2 Cabling IP4WW-008E-A1............................................................ 2-51
3.4.3 Cabling IP4WW-000E-A1............................................................ 2-52
3.4.4 Cabling and Setting IP4WW-2BRIDB-C1.................................... 2-52
3.4.5 Cabling and Setting IP4WW-1PRIU-C1...................................... 2-55
3.5 Power Failure Transfer (408E-A1 only)........................................ 2-58
3.5.1 General....................................................................................... 2-58
3.5.2 Power Failure Setting.................................................................. 2-59
Section 4 INSTALLING THE OPTIONAL INTERFACE CARDS..... 2-60
4.1 Installing the Expansion Memory Card (MEMDB-C1).................. 2-60
4.1.1 General....................................................................................... 2-60
SL1000 ISSUE 4.0
ii Hardware Manual
4.1.2 Unpacking................................................................................... 2-60
4.1.3 Installing the MEMDB PCB......................................................... 2-60
4.2 VoIP Card (VOIPDB-C1) ............................................................. 2-63
4.2.1 General....................................................................................... 2-63
4.2.2 Unpacking................................................................................... 2-63
4.2.3 Installing the VOIPDB-C1 PCB................................................... 2-63
4.2.4 LED Indication............................................................................. 2-67
4.3 VRS/Voice Mail Card (PZ-VM21)................................................. 2-68
4.3.1 General....................................................................................... 2-68
4.3.2 Unpacking................................................................................... 2-68
4.3.3 Installing the PZ-VM21 PCB....................................................... 2-68
4.4 Installing the CF Card (CFVRS/CFVMS/CFVML)......................... 2-71
Section 5 INSTALLING THE MULTILINE TELEPHONES
AND OPTIONAL TERMINALS.................................... 2-73
5.1 Installing the Multiline Telephones................................................ 2-73
5.1.1 Location of Controls.................................................................... 2-73
5.1.2 Multiline Telephone Legs Adjustment......................................... 2-74
5.1.3 Wall-Mounting the Multiline Telephone ...................................... 2-76
5.2 Install the IP Multiline Telephone (IP4WW-24TIXH-C1 TEL)....... 2-78
5.2.1 System Connection..................................................................... 2-78
5.2.2 Installing the IP Multiline Telephone........................................... 2-78
5.2.3 Applying Power to the IP Multiline Telephone............................. 2-79
5.3 Installing the DSS Console........................................................... 2-79
5.3.1 DSS Console Leg Adjustment..................................................... 2-79
5.3.2 Wall-Mounting the DSS Console................................................. 2-81
5.4 Installing the Headset................................................................... 2-82
5.5 Installing the Doorphone Box........................................................ 2-83
5.5.1 Wall-Mounting the Doorphone.................................................... 2-83
5.5.2 Connecting the Doorphone......................................................... 2-85
5.5.3 Doorphone Interface Specifications............................................ 2-85
5.6 Installing the Door Unlock Devices............................................... 2-85
5.7 Installing the External Paging Speaker/External MOH/BGM
Sources.................................................................................. 2-87
5.7.1 Connecting the Audio Equipment................................................ 2-87
5.7.2 External Paging Output Specifications........................................ 2-87
5.7.3 BGM/External MOH Source Input Specifications........................ 2-88
5.8 SMDR (Station Message Detail Recording)................................. 2-88
5.8.1 General....................................................................................... 2-88
Chapter 3 System Start Up
Section 1 SYSTEM START UP.......................................................... 3-1
1.1 Before Starting Up the System....................................................... 3-1
1.2 Starting Up the System................................................................... 3-1
1.2.1 Perform a Cold Start..................................................................... 3-2
1.2.2 Perform a Hot Start....................................................................... 3-3
Section 2 PROGRAMMING MODE .................................................. 3-4
2.1 Entering the Programming Mode.................................................... 3-4
2.2 Exiting the Programming Mode...................................................... 3-4
ISSUE 4.0 SL1000
Hardware Manual iii
2.3 Saving (Backup) the Customer Data.............................................. 3-4
2.4 Loading the Customer Data............................................................ 3-5
Section 3 SYSTEM SHUT DOWN..................................................... 3-7
3.1 Powering Off the System................................................................ 3-7
3.2 Resetting the System...................................................................... 3-7
Chapter 4 Maintenance
Section 1 FUSE REPLACEMENT..................................................... 4-1
1.1 Replacing the Fuse......................................................................... 4-1
Section 2 LITHIUM BATTERY REPLACEMENT.............................. 4-4
2.1 General........................................................................................... 4-4
2.2 Lithium Battery Specification.......................................................... 4-4
2.3 Replacing the Lithium Battery......................................................... 4-5
Section 3 MAIN SOFTWARE UPGRADING...................................... 4-9
3.1 General........................................................................................... 4-9
3.2 Before Upgrading the Main Software.............................................. 4-9
3.3 Main Software Version Confirmation.............................................. 4-9
3.4 Upgrading the Main Software....................................................... 4-10
Section 4 LED INDICATIONS.......................................................... 4-13
Chapter 5 Specifications
Section 1 SYSTEM CAPACITY......................................................... 5-1
Section 2 SYSTEM SPECIFICATIONS............................................. 5-3
2.1 General Precautions....................................................................... 5-3
2.2 Environmental Requirements......................................................... 5-3
2.3 Operating Conditions...................................................................... 5-3
2.4 Site Requirements.......................................................................... 5-3
2.5 AC Power Requirement.................................................................. 5-3
2.6 Electrical Specifications <Power Supply> (KSU)............................ 5-4
2.7 CPU................................................................................................ 5-4
2.8 Traffic Capacity............................................................................... 5-5
2.9 IP Terminal Power Chart................................................................ 5-5
2.10 IEEE802.af Class Specification.................................................... 5-5
2.11 Mechanical Specifications............................................................ 5-5
2.12 Optional Unit Mechanical Specifications....................................... 5-5
2.13 Doorphone Interface Specifications.............................................. 5-6
2.14 General Purpose/Door Unlock Relay Specifications.................... 5-6
2.15 External Paging Output Specifications......................................... 5-6
2.16 BGM/ExMOH Source Input Specifications................................... 5-7
2.17 External Sensor Device Interface Specifications.......................... 5-7
2.18 CPU Card LAN Port Specifications............................................... 5-7
2.19 Cabling Requirements ................................................................. 5-7
2.20 Cable Requirements..................................................................... 5-8
SL1000 ISSUE 4.0
iv Hardware Manual
LIST OF TABLES
Table 1-1 Memory Capacity of MEMDB-C1....................................................................... 1-6
Table 1-2 System Capacity................................................................................................ 1-9
Table 2-1 KSU Packing List............................................................................................... 2-2
Table 2-2 Items on the CPU card...................................................................................... 2-3
Table 2-3 EXIFB-C1 Packing List...................................................................................... 2-9
Table 2-4 Connectors of EXIFB-C1................................................................................... 2-9
Table 2-5 Power Requirement......................................................................................... 2-13
Table 2-6 IP4WW-Battery Box Packing List.................................................................... 2-20
Table 2-7 Battery Specifications...................................................................................... 2-21
Table 2-8 Expansion Cards............................................................................................. 2-42
Table 2-9 Expansion Card Packing List........................................................................... 2-42
Table 2-10 RJ-61 BRI Pin-Outs (S-Bus, T-Bus) ............................................................. 2-53
Table 2-11 Switch Setting of 2BRIDB-C1........................................................................ 2-54
Table 2-12 RJ-45 PRI Pin-Outs (S-Bus, T-Bus) ............................................................. 2-55
Table 2-13 Switch Setting of 1PRIU-C1........................................................................... 2-55
Table 2-14 LED Indication............................................................................................... 2-56
Table 2-15 T1 LED Indications........................................................................................ 2-57
Table 2-16 E1 LED Indications........................................................................................ 2-58
Table 2-17 MEMDB-C1 Packing List............................................................................... 2-60
Table 2-18 VOIPDB-C1 Packing List............................................................................... 2-63
Table 2-19 VOIPDB LED Indications............................................................................... 2-68
Table 2-20 Operation of VOIPDB LED Indications.......................................................... 2-68
Table 2-21 PZ-VM21 Packing List................................................................................... 2-68
Table 2-22 Multiline Telephone Functions (12TXH/24TXH/24TIXH (IP)) ....................... 2-73
Table 2-23 Doorphone Interface Specifications............................................................... 2-85
Table 2-24 RJ-61 General Purpose/Door Unlock Relay Control Connector (J7)............. 2-86
Table 2-25 General Purpose/Door Unlock Relay Specifications..................................... 2-86
Table 2-26 External Paging Output Specifications.......................................................... 2-87
Table 2-27 BGM/External MOH Source Input Specifications.......................................... 2-88
Table 3-1 Start Up Method................................................................................................. 3-1
Table 4-1 Status LEDs..................................................................................................... 4-11
Table 4-2 CPU LED Indications....................................................................................... 4-13
Table 5-1 System Capacity................................................................................................ 5-1
Table 5-2 Operating Conditions......................................................................................... 5-3
Table 5-3 Power Requirement........................................................................................... 5-3
Table 5-4 Electrical Specifications of KSU......................................................................... 5-4
Table 5-5 IP Terminal Power Chart................................................................................... 5-5
Table 5-6 IEEE802.af Class Specification......................................................................... 5-5
Table 5-7 Mechanical Specifications................................................................................. 5-5
Table 5-8 Optional Unit Mechanical Specifications............................................................ 5-5
Table 5-9 Doorphone Interface Specifications................................................................... 5-6
Table 5-10 General Purpose/Door Unlock Relay Specifications....................................... 5-6
Table 5-11 External Paging Output Specifications............................................................ 5-6
Table 5-12 BGM/External MOH Source Input Specifications............................................ 5-7
Table 5-13 External Sensor Device Interface Specifications............................................. 5-7
Table 5-14 CPU Card LAN Port Specifications.................................................................. 5-7
Table 5-15 Cable Requirements........................................................................................ 5-8
ISSUE 4.0 SL1000
Hardware Manual v
LIST OF FIGURES
Figure 1-1 System Configuration....................................................................................... 1-1
Figure 1-2 System Image................................................................................................. 1-11
Figure 1-3 Maximum KSU Capacity - Expandability of Trunk and Extension
(without PRI)............................................................................................. 1-12
Figure 1-4 Maximum KSU Capacity - Expandability of Trunk and Extension (with
PRI)........................................................................................................... 1-13
Figure 2-1 CPU Card Location........................................................................................... 2-3
Figure 2-2 Dimension of the Main and Expansion KSU..................................................... 2-4
Figure 2-3 Vertical Arrangement of KSUs.......................................................................... 2-5
Figure 2-4 Horizontal Arrangement of KSUs..................................................................... 2-6
Figure 2-5 Wall-Mounting Template................................................................................... 2-6
Figure 2-6 Screw Positions................................................................................................ 2-7
Figure 2-7 Sub-Cover Slide-out......................................................................................... 2-7
Figure 2-8 Removing the Sub-Cover................................................................................. 2-8
Figure 2-9 Sub-Cover Open Position................................................................................. 2-8
Figure 2-10 Mounting the KSU.......................................................................................... 2-8
Figure 2-11 Connectors of EXIFB-C1................................................................................ 2-9
Figure 2-12 Removing the Sub-Cover ............................................................................ 2-10
Figure 2-13 Removing the Main-Cover ........................................................................... 2-10
Figure 2-14 EXIFB-C1 PCB Installation........................................................................... 2-11
Figure 2-15 Removing the Plastic Knockouts.................................................................. 2-11
Figure 2-16 Replacing the Main-Cover............................................................................ 2-11
Figure 2-17 Connection of KSUs..................................................................................... 2-12
Figure 2-18 ETH Lug....................................................................................................... 2-13
Figure 2-19 AC Power Cord............................................................................................. 2-14
Figure 2-20 Sub-Cover Open and Hold........................................................................... 2-15
Figure 2-21 Trunk Cabling............................................................................................... 2-16
Figure 2-22 Extension Cabling......................................................................................... 2-17
Figure 2-23 PF/KT Switch of 408M-A1............................................................................ 2-18
Figure 2-24 Cabling......................................................................................................... 2-19
Figure 2-25 Sub-Cover.................................................................................................... 2-19
Figure 2-26 Dimension of the IP4WW-Battery Box.......................................................... 2-21
Figure 2-27 Removing the Front Cover .......................................................................... 2-22
Figure 2-28 Disconnect Battery Connection Cable.......................................................... 2-22
Figure 2-29 Batt Stopper.................................................................................................. 2-23
Figure 2-30 Pulling out the Battery Tray ......................................................................... 2-23
Figure 2-31 Remove the Battery Tray Bracket ............................................................... 2-24
Figure 2-32 Battery Installation........................................................................................ 2-24
Figure 2-33 Connecting the Battery Cables..................................................................... 2-25
Figure 2-34 Installation of Battery Tray Cover................................................................. 2-25
Figure 2-35 Inserting the Battery Tray............................................................................. 2-26
Figure 2-36 Secure Batt Stopper Bracket........................................................................ 2-26
Figure 2-37 Connecting the Battery Connection Cable................................................... 2-27
Figure 2-38 Installation of Front Cover............................................................................ 2-27
Figure 2-39 Bases and Support of the Battery Box......................................................... 2-28
Figure 2-40 Floor-Mount Spacing Guide.......................................................................... 2-28
Figure 2-41 Mounting the Battery Box............................................................................. 2-29
Figure 2-42 Securing the Battery Box.............................................................................. 2-29
Figure 2-43 Assemble Battery Box Base......................................................................... 2-30
Figure 2-44 Wall-Mount Spacing Guide........................................................................... 2-31
Figure 2-45 Removing the Front Cover .......................................................................... 2-32
SL1000 ISSUE 4.0
vi Hardware Manual
Figure 2-46 Mounting the Battery Box............................................................................. 2-32
Figure 2-47 Securing the Battery Box.............................................................................. 2-33
Figure 2-48 Removing the Front Cover .......................................................................... 2-33
Figure 2-49 Removing the L-Bracket .............................................................................. 2-34
Figure 2-50 Securing the L-Bracket and WM Hook......................................................... 2-35
Figure 2-51 Attaching the KSU........................................................................................ 2-35
Figure 2-52 KSU Mounting on Battery Box...................................................................... 2-36
Figure 2-53 Sub-Cover Open and Hold........................................................................... 2-36
Figure 2-54 Connecting Battery Cable............................................................................. 2-37
Figure 2-55 Removing the Front Cover .......................................................................... 2-38
Figure 2-56 Disconnecting the Battery Connection Cable............................................... 2-38
Figure 2-57 Loosen the Fuse Unit Screw........................................................................ 2-39
Figure 2-58 Replacing the Fuse....................................................................................... 2-39
Figure 2-59 Install the Fuse Unit...................................................................................... 2-39
Figure 2-60 Securing the Fuse Unit................................................................................. 2-40
Figure 2-61 Connect Battery Connection Cable.............................................................. 2-40
Figure 2-62 Installation of the Front Cover...................................................................... 2-41
Figure 2-63 Removing the Sub-cover ............................................................................. 2-43
Figure 2-64 Removing the Main-cover ............................................................................ 2-44
Figure 2-65 Mounting of the 1st Expansion Interface Card............................................. 2-44
Figure 2-66 Mounting the 2nd Expansion Interface Card................................................ 2-45
Figure 2-67 Mounting the 3rd Expansion Interface Card................................................. 2-46
Figure 2-68 Mounting Three Expansion Interface Cards................................................. 2-46
Figure 2-69 Plastic Knockouts......................................................................................... 2-47
Figure 2-70 Replacing the Main-cover............................................................................. 2-47
Figure 2-71 Plastic Knockouts on 008E-A1/000E-A1...................................................... 2-48
Figure 2-72 Installing the 2BRIDB-C1.............................................................................. 2-48
Figure 2-73 Mounting the 2BRIDB-C1 into the KSU........................................................ 2-49
Figure 2-74 Replacing the Main-Cover............................................................................ 2-49
Figure 2-75 Connectors of 408E-A1................................................................................ 2-51
Figure 2-76 Connectors of 008E-A1................................................................................ 2-52
Figure 2-77 Connectors of 2BRIDB-C1........................................................................... 2-53
Figure 2-78 Switches Location of 2BRIDB-C1................................................................. 2-54
Figure 2-79 Connector of 1PRIU-C1................................................................................ 2-55
Figure 2-80 Switches and LEDs Location of 1PRIU-C1.................................................. 2-56
Figure 2-81 1PRIU-C1 LED Indication Pattern of Layer 1 on T1 Unit.............................. 2-57
Figure 2-82 1PRIU-C1 LED Indication Pattern of Layer 1 on E1 Unit............................. 2-58
Figure 2-83 PF/KT Switch of 408E-A1............................................................................. 2-59
Figure 2-84 Removing the Sub-Cover ............................................................................ 2-60
Figure 2-85 Removing the Main-Cover ........................................................................... 2-61
Figure 2-86 Removing the CPU Card ............................................................................. 2-61
Figure 2-87 Installing the MEMDB PCB........................................................................... 2-62
Figure 2-88 Installing the CPU Card................................................................................ 2-62
Figure 2-89 Replacing the Main-Cover............................................................................ 2-63
Figure 2-90 Removing the Sub-Cover ............................................................................ 2-64
Figure 2-91 Removing the Main-Cover ........................................................................... 2-64
Figure 2-92 Removing the CPU Card ............................................................................. 2-65
Figure 2-93 Installing the VOIPDB-C1 PCB..................................................................... 2-65
Figure 2-94 Installing the CPU Card................................................................................ 2-66
Figure 2-95 Removing the Plastic Knockout and Replacing the Main-Cover.................. 2-66
Figure 2-96 Connecting a LAN Cable.............................................................................. 2-67
Figure 2-97 Location of LEDs.......................................................................................... 2-67
Figure 2-98 Removing the Sub-Cover ............................................................................ 2-69
ISSUE 4.0 SL1000
Hardware Manual vii
Figure 2-99 Removing the Main-Cover............................................................................ 2-69
Figure 2-100 Removing the CPU Card............................................................................ 2-70
Figure 2-101 Installing the PZ-VM21 PCB....................................................................... 2-70
Figure 2-102 Installing the CPU Card.............................................................................. 2-71
Figure 2-103 Replacing the Main-Cover.......................................................................... 2-71
Figure 2-104 Installing the CF Card................................................................................. 2-72
Figure 2-105 Multiline Telephone (12TXH/24TXH/24TIXH (IP))...................................... 2-73
Figure 2-106 Leg Setting for Low Position....................................................................... 2-74
Figure 2-107 Cabling of Multiline Telephone................................................................... 2-74
Figure 2-108 Setting for High Position............................................................................. 2-75
Figure 2-109 Leg Setting for High Position...................................................................... 2-75
Figure 2-110 Cabling for Wall-Mount............................................................................... 2-76
Figure 2-111 Wall-Mount Unit - 24TIXH-C....................................................................... 2-76
Figure 2-112 Hook-Switch Hanger................................................................................... 2-77
Figure 2-113 Wall-Mount Screw Guide............................................................................ 2-77
Figure 2-114 Mounting the Multiline Telephone............................................................... 2-77
Figure 2-115 IP Multiline Telephone Connection............................................................. 2-78
Figure 2-116 IP Multiline Telephone Connectors............................................................. 2-78
Figure 2-117 Low Position Setting................................................................................... 2-79
Figure 2-118 Cabling of DSS........................................................................................... 2-80
Figure 2-119 Leg Stopper of DSS Console..................................................................... 2-80
Figure 2-120 High Position Setting.................................................................................. 2-81
Figure 2-121 Cabling for Wall-Mount............................................................................... 2-81
Figure 2-122 Wall-Mount Screw Guide............................................................................ 2-82
Figure 2-123 Mounting the DSS...................................................................................... 2-82
Figure 2-124 Handset Socket.......................................................................................... 2-83
Figure 2-125 Headset Socket.......................................................................................... 2-83
Figure 2-126 Doorphone Box and Bracket...................................................................... 2-84
Figure 2-127 Doorphone.................................................................................................. 2-84
Figure 2-128 Connecting the Doorphone......................................................................... 2-85
Figure 2-129 Connecting the Door Unlock Device........................................................... 2-86
Figure 2-130 Connecting Audio Equipment..................................................................... 2-87
Figure 2-131 Connecting a PC for SMDR........................................................................ 2-88
Figure 3-1 Lithium Battery Protection Sheet...................................................................... 3-1
Figure 3-2 Power Switch Location..................................................................................... 3-2
Figure 3-3 Load Button (S1) Location................................................................................ 3-2
Figure 3-4 Status LED (D5) and RUN LED Location......................................................... 3-3
Figure 3-5 Display Indication (Idle) ................................................................................... 3-3
Figure 3-6 Entering Programming Mode Display 1............................................................ 3-4
Figure 3-7 Entering Programming Mode Display 2............................................................ 3-4
Figure 3-8 Exiting the Programming Mode Display 1........................................................ 3-4
Figure 3-9 Exiting Programming Mode Display 2.............................................................. 3-4
Figure 3-10 Inserting the CF card...................................................................................... 3-5
Figure 3-11 PRG90-03 Display.......................................................................................... 3-5
Figure 3-12 PRG90-04 Display.......................................................................................... 3-5
Figure 3-13 Inserting the CF card...................................................................................... 3-6
Figure 3-14 PRG90-04 Display.......................................................................................... 3-6
Figure 3-15 Next PRG Display........................................................................................... 3-6
Figure 3-16 Power Switch Location................................................................................... 3-7
Figure 4-1 Removing the Sub-Cover................................................................................. 4-1
Figure 4-2 Removing the Main-Cover................................................................................ 4-2
Figure 4-3 Exchanging the Fuse........................................................................................ 4-2
Figure 4-4 Replacing the Main-Cover................................................................................ 4-3
SL1000 ISSUE 4.0
viii Hardware Manual
Figure 4-5 Warning of Low Battery.................................................................................... 4-4
Figure 4-6 Removing the Sub-Cover................................................................................. 4-5
Figure 4-7 Disconnecting the AC Power Cord................................................................... 4-5
Figure 4-8 Removing the Main-Cover................................................................................ 4-6
Figure 4-9 Removing the CPU Card.................................................................................. 4-6
Figure 4-10 Location of Lithium Battery Socket................................................................. 4-7
Figure 4-11 Removing the Lithium Battery........................................................................ 4-7
Figure 4-12 Inserting the Lithium Battery........................................................................... 4-7
Figure 4-13 Installing the CPU Card.................................................................................. 4-8
Figure 4-14 Display of Multiline Telephone........................................................................ 4-9
Figure 4-15 Removing the Sub-Cover............................................................................. 4-10
Figure 4-16 Removing the Main-Cover............................................................................ 4-10
Figure 4-17 Inserting the CF card.................................................................................... 4-11
Figure 4-18 LOAD Button (S1) Location.......................................................................... 4-11
Figure 4-19 Removing the CF card.................................................................................. 4-12
ISSUE 4.0 SL1000
Hardware Manual ix
MEMO
SL1000 ISSUE 4.0
x Hardware Manual
Regulatory
BATTERY DISPOSAL
The SL1000 system includes the batteries listed below. When disposing of these batteries, KSU,
and/or Unit, you must comply with applicable regulations relating to your location regarding proper
disposal procedures.
Unit Name Type of Battery Quantity Note
IP4[ ]-CPU-A1 Lithium 1
External Battery
(IP4WW-Battery Box)
Sealed Lead 2 per IP4WW-Battery Box
The SL1000 IP4[ ]-CPU-A1 provides memory backup for approximately three years. The Lithium
battery should be replaced every two years.
IMPORTANT SAFEGUARDS FOR BATTERY DISPOSAL
DO NOT PLACE USED BATTERIES IN YOUR REGULAR WASTE! THE PRODUCT YOU
PURCHASED CONTAINS LITHIUM, SEALED LEAD BATTERIES. LITHIUM, SEALED LEAD
BATTERIES MUST BE COLLECTED, RECYCLED, OR DISPOSED OF IN AN ENVIRONMENTALLY
SOUND MANNER.
The incineration, landfilling or mixing of sealed lead batteries with the municipal solid waste stream is
PROHIBITED BY LAW in most areas. Contact your local solid waste management officials for other
information regarding the environmentally sound collection, recycling, and disposal of the battery.
Sealed lead batteries must be returned to an approved sealed lead battery recycler. This may be
where the batteries were originally sold or a local seller of automotive batteries. Contact your local
waste management officials for other information regarding the environmentally sound collection,
recycling and disposal of the battery contained in this product.
The packaging for the SL1000 system contains the following labels regarding proper disposal.
CONTAINS SEALED LEAD BATTERY.
BATTERY MUST BE RECYCLED. MUST NOT
BE DISPOSED OF IN MUNICIPAL WASTE.
Pb
EUROPEAN UNION INFORMATION
Notice to the user
The system described in this manual is intended to be connected to analog and digital networks and
supports a wide range of peripheral equipment. The following interfaces are available for connection to
public analog and digital telecommunication networks:
TBR3 ISDN basic rate interface
TBR4 ISDN primary rate interface
ES203-021 Analogue interface
ISSUE 4.0 SL1000
Hardware Manual R-1
To take advantage of all features of this system and the connected equipment, the country or network
specific features should match the supported features of the system. For an overview of the supported
features, refer to the detailed documentation that comes with this system, contact your local NEC
Unified Solutions representative or the support desk of NEC Unified Solutions.
Declaration of conformity
Hereby, NEC Unified Solutions, declares that the SL1000 is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC.
For the Declaration of Conformity, visit: http://www.nec-unified.com/doc
Electromagnetic Compatibility
For the SL1000 system the following warning is applicable:
Warning
This is a class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
PRODUCT DISPOSAL INFORMATION
For Countries in the European Union
The symbol depicted here has been affixed to your product to inform you that electrical and electronic
products should not be disposed of as municipal waste.
Electrical and electronic products including the cables, plugs and accessories should be disposed of
separately to allow proper treatment, recovery and recycling. These products should be taken to a
designated facility where the best available treatment, recovery and recycling techniques are
available. Separate disposal has significant advantages: valuable materials can be re-used and it
prevents the dispersion of unwanted substances into the municipal waste stream. This contributes to
the protection of human health and the environment.
SL1000 ISSUE 4.0
R-2 Regulatory
Please be informed that a fine may be imposed for illegal disposal of electrical and electronic products
via the general municipal waste stream.
To facilitate separate disposal and environmentally sound recycling arrangements have been made for
local collection and recycling. If your electrical and electronic products must be disposed of please
refer to your supplier or the contractual agreements that your company has made upon acquisition of
these products.
At www.nec-unified.com/weee you can find information about separate disposal and environmentally
sound recycling.
BATTERY INFORMATION
Defective or exhausted batteries should never be disposed of as municipal waste. Return old batteries
to the battery supplier, a licensed battery dealer or a designated collection facility. Do not incinerate
batteries. This product uses Lithium batteries. Do not use any other type.
For an overview of the location of batteries used in these systems, the battery replacement or removal
instructions, please refer to the SL1000 System Hardware Manual.
HEARING AID COMPATIBILITY
NEC Multiline Terminals and NEC Single Line Telephones that are provided for this system are
hearing aid compatible. The manufacturer of other Single Line Telephones for use with the system
must provide notice of hearing aid compatibility to comply with FCC rules that now prohibit the use of
non-hearing aid compatible telephones.
ISSUE 4.0 SL1000
Hardware Manual R-3
MEMO
SL1000 ISSUE 4.0
R-4 Regulatory
Introduction
SECTION 1 GENERAL INFORMATION
Designed to support small/medium businesses with simple installation and easy operation.
Small compact KSU comes with basic configuration of CPU, four analog trunk ports and eight hybrid
extension ports and has three stackable slots for further expansion.
The system can be increased to a maximum of 48 analog trunks and 96 Multiline extensions by
adding up three more expansion KSUs, also equipped to support Digital Network (BRI/PRI, E1), IP
Trunks (SIP/H.323) and IP extensions.
IP/VoIP
PSTN
ISDN
Multiline Telephone (4-wire)
DSS Console
Analog Telephone
FAX
DoorBox
Door Opener
External Paging System
CTI Server
Relay Control Port
KSU4
KSU3
KSU2
KSU1
Remote PC
Expanded
Embedded VRS/VM
Backup Battery
PC
PCPro/ Web Pro
Hybrid Port
Analog Trunk Port
External Music Source
(EXMOH, BGM..)
(General Purpose Relay)
Multiline IP Telephone
Office LAN/CTI
Figure 1-1 System Configuration
Hardware Manual 1-1
I
n
t
r
o
d
u
c
t
i
o
n
1
SECTION 2 EQUIPMENT LIST
The following table lists all equipment for the SL1000 system.
Stock Number Equipment Name Equipment Description Note
BE110233 IP4EU-1632M-A KSU w/o
C
IP4EU-1632M-A KSU without AC Cable (for EMEA)
<Including> IP4EU-CPU-A1, IP4WW-408M-A1, Power
Supply

BE110234 IP4EU-1632M-A KSU IP4EU-1632M-A KSU with AC Cable (for EMEA)
<Including> IP4EU-CPU-A1, IP4WW-408M-A1, Power
Supply

BE110236 IP4WW-1632ME-A EXP
w/o C
IP4WW-1632ME-A EXP without AC Cable
<Including> IP4WW-EXIFE-C1, IP4WW-408M-A1,
Power Supply

BE110237 IP4WW-1632ME-A EXP IP4WW-1632ME-A EXP with AC Cable
<Including> IP4WW-EXIFE-C1, IP4WW-408M-A1,
Power Supply

BE110258 IP4WW-EXIFB-C1 Expansion KSU Interface Unit, 3 jacks
BE110239 IP4WW-Battery Box External Battery Box without Batteries
BE110250 IP4WW-408E-A1 4-port Loop Start Trunks and 8-port Hybrid Station In-
terface

BE110251 IP4WW-008E-A1 8-port Hybrid Station Interface
BE110252 IP4WW-000E-A1 Extension board for 2BRIDB daughter board
BE110257 IP4WW-2BRIDB-C1 2 Basic Rate Interface, mounted on 008E-A1/000E-A1
board

BE110255 IP4WW-1PRIU-C1 1 Primary Rate Interface (PRI/E1/T1)
BE110247 IP4EU-MEMDB-C1 Memory Expansion on CPU (for EMEA)
BE110290 IP4WW-VOIPDB-C1 16-channel VOIP on CPU
BE106339 PZ-VM21 16 Channels for Voice Mail with a Single Channel V.34
Modem

BE110730 IP4WW-CFVRS-C1 Compact Flash for VRS (VRS: 4ch (default))
BE110731 IP4WW-CFVMS-C1 Compact Flash for VRS and InMail ( Approx. 15 hours,
VRS: 4ch (default)/InMail: 2ch (default))

BE110732 IP4WW-CFVML-C1 Compact Flash for VRS and InMail ( Approx. 40 hours,
VRS: 4ch (default)/InMail: 4ch (default))

BE110261 IP4WW-12TXH-A-TEL
(WH)
4-wire 12-key Multiline Telephone
BE110262 IP4WW-12TXH-A-TEL
(BK)
BE110263 IP4WW-24TXH-A-TEL
(WH)
4-wire 24-key Multiline Telephone
BE110264 IP4WW-24TXH-A-TEL
(BK)
BE110277 IP4WW-24TIXH-C-TEL
(WH)
24-Keys, Multiline IP Telephone
BE110278 IP4WW-24TIXH-C-TEL
(BK)
BE110281 IP4WW-60D DSS-A
CONSOLE (WH)
60-button Direct Station Selection (DSS) Console
BE110282 IP4WW-60D DSS-A
CONSOLE (BK)
BE108045 DP-D-1D Doorphone
BE109741 DX4NA Doorphone Doorphone
BE109742 HS.D503DOR-A Doorphone
SL1000 ISSUE 4.0
1-2 Introduction
Stock Number Equipment Name Equipment Description Note
BE108057 AC-LE UNIT AC/DC Adapter for 24TIXH TEL (w/o AC Cable)
BE110752 SL-IP-SIPTRK-1 LIC SIP Trunk License (1 port)
BE111175 SL-IP-SIPEXT-1 LIC Standard SIP Terminal License (1 port)
BE110753 SL-IP-ENCRYPTION LIC Encryption License for Multiline IP Telephone (1 li-
cense per system)

BE110754 SL-IP-NAPT LIC NAPT License for Multiline IP Telephone (1 license per
system)

BE110755 SL-VM-CHANNEL-2 LIC Additional InMail Channel License (2 ports)
BE110733 SL-VM-ADVANCE LIC InMail Advanced Features License (1 license per sys-
tem)

BE110756 SL-SYS-MOBILE-1 LIC Additional Mobile Extension Port License (1 port)
BE110757 SL-SYS-HOTEL LIC Hotel/Motel Feature License (1 license per system)
BE111312 SL-DT-DESKTOP
SUITE-1 LIC
Desktop Client with Soft phone Client License (1 Cli-
ent)

BE111676 SL-SYS-PMS-32ROOMS
LIC
Hotel/Motel PMS License (32 Rooms) (V2.0 Added)
BE111780 SL-SYS-3RD-CTI LIC 3rd Party CTI Client License (V2.0 Added)
BE111493 SL-SYS-XMLPro-LIC XMLPro License (1 license per system) (V2.0 Added)
BE110790 IP4WW-WALL MOUNT
UNIT
Wall-Mount Unit for IP4WW-24TIXH-C-TEL
2.1 KSUs and Optional Unit
2.1.1 IP4[ ]-1632M-A KSU
The Main or controlling KSU is shipped fully assembled. The following are included with the KSU:
CPU with main software (CPU-A1)
Power supply (110V/240V)
1 External backup battery connector
3 mounting spaces for 408E/008E/000E/1PRIU
(3rd Slot of each KSU can not use for 4-Wire Multiline
Telephone or DSS Console.)
4 trunks + 8 hybrid Ext. I/F (408M-A1)
1 power failure transfer circuit
1 slot for EXIFB-C1
2 general purpose relay
SLT ringer
Message waiting lamp driver
One built-in answering circuit (VRS)
The on-board DSP provides:
20 telephony resources (DTMF/Dial tone/Busy tone/FSK caller-ID receiver/sender)
128 tone sender resources (System tones sender/DTMF sender)
32 ch conference resources
ISSUE 4.0 SL1000
Hardware Manual 1-3
2.1.2 IP4[ ]-1632ME-A EXP
A maximum of three additional 1632ME EXPs can be connected to expand the system capacity of the
1632M KSU. Although similar in shape and size as the 1632M KSU, the capabilities are not the same.
The following are included with the 1632ME EXP:
Power supply (110V/240V)
1 external backup battery connector
3 mounting spaces for 408E/008E/000E/1PRIU
(3rd Slot of each KSU can not use for 4-Wire Multiline
Telephone or DSS Console.)
4 trunks + 8 hybrid Ext. I/F
1 power failure transfer circuit
EXIFE-C1 (1 connector for 1632M-A KSU)
2 general purpose relay
SLT ringer
Message waiting lamp driver
The EXIFE DSP provides:
32 telephony resources (DTMF/Dial tone/Busy tone/FSK caller-ID receiver/sender)
The 1632ME-A EXP does NOT have CPU and main software and cannot be used in a stand-alone
mode.
2.1.3 IP4WW-EXIFB-C1
Using a Cat5 cable, EXIFB-C1 card installed in the Main
KSU is individually connected to each EXIFE-C1 card
(Expansion KSU).
Install this card to the Main KSU.
Three connections for Expansion KSUs
2.1.4 IP4WW-Battery Box
Connected to each KSU power supply, the external backup
battery provides DC power in case a loss of AC power
occurs. An optional (locally procured), external battery
source can be used to provide power during a power failure.
Connect this box to the power supply at each KSU.
Wall/floor-mountable
One KSU can be mounted on the Battery box.
Backup duration is approximately one hour.
SL1000 ISSUE 4.0
1-4 Introduction
2.2 Trunk/Extension/ISDN Expansion Interface Cards
2.2.1 IP4WW-408E-A1
This 408E card is installed in the 1632M KSU or 1632ME
EXP and provides a total of four analog trunk and eight
hybrid extension ports.
Install this card to the expansion card slot at Main/
Expansion KSU
Enables to connect the DSS console to hybrid Ext. port
No.8
1 power failure transfer circuit
2.2.2 IP4WW-008E-A1
This 008E card is installed in the 1632M KSU or 1632ME
EXP and provides a total of eight hybrid extension ports. The
ISDN BRI daughter board (2BRDB) can be mounted on this
board.
Install this card to the expansion card slot at Main/
Expansion KSU
Enables to connect the DSS console to hybrid extension
port No.8
One ISDN BRI daughter board connection
2.2.3 IP4WW-000E-A1
This is an expansion card for mounting 2BRIDB board, and
is installed into 1632M KSU/1632ME EXP.
Install this card to the expansion card slot at Main/
Expansion KSU
One ISDN BRI daughter board connection
2.2.4 IP4WW-2BRIDB-C1
The 2BRIDB provides two ISDN (Basic Rate) circuit and is
mounted on the 008E or 000E card. A total of nine 2BRIDBs
can be installed per system or three 2BRIDBs per KSU.
Mount this board onto the 008E or 000E card.
Supports T/S point connection (Hard-switch).
All ISDN circuits are not supplied with DC power from the
system.
ISSUE 4.0 SL1000
Hardware Manual 1-5
2.2.5 IP4WW-1PRIU-C1
The 1PRIU is installed in the 1632M KSU or 1632ME EXP
providing for either an ISDN Primary Rate Interface, T1
Interface or E1 interface. A total of three 1PRIUs can be
installed per system or one 1PRIU per KSU.
Install this card to the expansion card slot at Main/
Expansion KSU.
Supports T/S point connection (Hard-switch).
2.3 Optional Interface Cards
2.3.1 IP4[ ]-MEMDB-C1
This card provides additional expansion memory. Following memories are equipped on this card.
Table 1-1 Memory Capacity of MEMDB-C1
Memory Type Capacity
SDRAM 64 MB
Flash Memory 32 MB
The MEMDB is mounted on the CPU card and provides the
SDRAM and Flash Memory required by the following:
Expansion KSU(s)
VoIP
CTI
Remote Upgrade (main software)
VRS Channel Increment
InMail Channel Increment
2.3.2 IP4WW-VOIPDB-C1
The VOIPDB-C1 card provides the RTP/RTCP voice
processing function.
Mount this card onto the CPU card (VoIPDB slot) at Main
KSU.
Max. 16 channels.
SL1000 ISSUE 4.0
1-6 Introduction
2.3.3 PZ-VM21
The PZ-VM21 daughter board provides additional Voice
Response and Voice Mail functionality using a Compact
Flash (CF) interface and a single channel V.34 modem.
Mount this card onto the CPU card (VMDB slot) at Main
KSU.
V.34 (33.6kbps) analog modem is initially mounted (for
remote maintenance.
VRS/VM CF card is separate preparation.
2.3.4 IP4WW-CFVRS-C1/IP4WW-CFVMS-C1/IP4WW-CFVML-C1
Three types of VRS/VM CF cards are available:
Install into the PZ-VM21 mounted on the CPU card at
Main KSU.
CFVRS: 4-channel VRS
CFVMS: VRS and 2-channel InMail (Approx. 15 hours)
CFVML: VRS and 4-channel InMail (Approx. 40 hours)
2.4 Multiline Telephones and Optional Equipment
2.4.1 IP4WW-12TXH-A TEL
The 12TXH-A TEL is a 4-wire multiline telephone featuring:
Programmable keys: 12
LCD: 16 digits x 2 lines
Handsfree: Half-duplex
Backlit dial pad: No
Angle Adjustment: 2-steps
Wall-Mounting kit: Built-in
2.4.2 IP4WW-24TXH-A TEL
The 24TXH-A TEL is a 4-wire multiline telephone featuring:
Programmable keys: 24
LCD: 16 digits x 2 lines
Handsfree: Half-duplex
Backlit dial pad: No
Angle Adjustment: 2-steps
Wall-Mounting kit: Built-in
ISSUE 4.0 SL1000
Hardware Manual 1-7
2.4.3 IP4[ ]-24TIXH-C TEL
The 24TIXH-C TEL is an IP multiline telephone featuring:
Programmable keys: 24
Soft Keys: 4
LCD: 24 digits x 3 lines with Backlit
Handsfree: Full-duplex
Interface: 2 x RJ45 Ethernet Ports (10Base-T/100Base-TX)
for LAN and PC
Power Feeding: AC Adapter (optional) or PoE (IEEE802.3af)
Support CODEC: G.711/G.729a/G.722
Backlit dial pad: Yes
Angle Adjustment: 2-steps
Wall-Mounting kit: IP4WW-WALL MOUNT UNIT (Optional)
2.4.4 IP4WW-60D DSS-A
The DSS console gives a multiline terminal user a Busy
Lamp Field (BLF) and one-button access to extensions,
trunks and system features. Mainly designed for operator
use, the 60-button DSS console provides an additional 60
programmable keys.
Connect this console to extension port No. 8 at 408M/
408E/008E of each KSU.
Programmable keys: 60
Angle Adjustment: 2-steps
Wall-Mounting kit: Built-in
2.4.5 DP-D-1D
This is the Doorphone Box.
Connects to hybrid port number 6 or 7 on the 408M of
each KSU.
SL1000 ISSUE 4.0
1-8 Introduction
SECTION 3 SYSTEM CAPACITY
3.1 System Capacity
Table 1-2 System Capacity
Items 1 KSU
(1632)
2 KSU
(3264)
3 KSU
(4896)
4 KSU
(64128)
Note
Expansion Slot 3 6 9 12 *4th slot of each KSU can not be used
for 4w Key Set.
*4th KSU can not be used for COI,
2BRIDB and 1PRIU.
System Maximum Port 66 132 198 230 1KSU: 408M+PRI+408Ex2
2KSU: 408Mx2+PRIx2+408Ex4
3KSU: 408Mx3+PRIx3+408Ex6
4KSU: 408Mx4+PRIx3+408Ex6
+008Ex3-400Mx1(4th KSU)
Trunk Port Max. 42 84 126 126 1KSU: 408M+PRIx1+408Ex2
2KSU: 408Mx2+PRIx2+408Ex4
3/4KSU: 408Mx3+PRIx3+408Ex6
Trunk Port Analog Trunks
(COT)
16 32 48 48 1KSU: 408M+408Ex3
2KSU: (408M+408Ex3) x2
3/4KSU: (408M+408Ex3)x3
BRI 12 24 36 36 1KSU: 2BRIx3 on 008E/000E
2KSU: 2BRIx6
3/4KSU: 2BRIx9
PRI (E1) 30 60 90 90 Max. 1 PRI/KSU
Max. 3 PRI/sys
IP Trunk (SIP/H.
323)
16 When MEMDB is installed
External Paging
(Audio Out)
1 2 3 3 1 audio In/Out and 2 audio In circuits on
408M (COI port 2: Paging, 3: MOH, 4:
BGM) Need the Program Setting. Alterna-
tive use with COT
External MOH
(Audio In)
1
External BGM
(Audio In)
1
Station Port Max. 32 64 96 128 1KSU: 408M+408Ex3
2KSU: 408Mx2+408Ex6
3KSU: 408Mx3+408Ex9
4KSU: 408Mx4+408Ex12
ISSUE 4.0 SL1000
Hardware Manual 1-9
Items 1 KSU
(1632)
2 KSU
(3264)
3 KSU
(4896)
4 KSU
(64128)
Note
Station Port 4W Key Set 24 48 72 96 Max. 24/KSU
SLT (28V) 32 64 96 128 1KSU: 408M+408Ex3
2KSU: 408Mx2+408Ex6
3KSU: 408Mx3+408Ex9
4KSU: 408Mx4+408Ex12
BRI (S-Point) 12 24 36 36 1KSU: 2BRIx3 on 008E/000E
2KSU: 2BRIx6 on 008E/000E
3KSU: 2BRIx9 on 008E/000E
4KSU: 2BRIx12 on 008E/000E
4W DSS Console 3 6 9 12 Max. 3/KSU
Connect to HBI Port 8 at 408M/408E/008E
Doorphone 2 4 6 8 2DPH I/F on 408M (HBI port 6,7)
Needs Program setting.
Alternative use with SLT
SIP-MLT/ SIP Std.
terminal
16 When MEMDB is installed
VRS Channels 4 CFVRS-C1
Max. 16 When MEMDB is installed
VM/VRS Channels 2 VM ports/ 4 VRS ports (default)
(Total Max.8 w/o MEMDB or 16 w/
MEMDB)
CFVMS-C1
Port increased by license.
4 VM ports/ 4 VRS ports (default)
(Total Max.8 w/o MEMDB or 16 w/
MEMDB)
CFVML-C1
Port increased by license.
Virtual Extension 50
Relay 2 4 6 8 2 circuits on 408M
Power Failure Transfer 4 8 12 12 1PFT circuit on 408M and 408E (COI port
1 and HBI port 8)
Needs HW switch change. Alternative use
with SLT.
Ethernet Port 1 1 circuit on CPU
Built-In Answering Machine Chan-
nel
1 1 circuit on CPU
VoIP Channels 16 When MEMDB is installed
V34 Modem 1 1 circuit on PZ-VM21
Conference Circuits 32 (Max. 16 parties per Conference) Mounted on CPU
DSP Resource
*1
20 For 1632M KSU (DSP on CPU)
16 When PZ-VM21 is installed
- 32 64 96 For 1632ME EXP 32ch DSP on each EX-
IFE-C1
DSP Sender
*2
128
*1. Service Tone receiver, DTMF receiver, Caller ID sender / receiver, MF receiver, MFC receiver
*2. Service Tone sender, DTMF sender, MF sender, MFC sender
3.2 KSU Capacity
System image of KSU capacity (ISDN, Trunk, Extension) is shown as below.
SL1000 ISSUE 4.0
1-10 Introduction
Expansion
Interface Card x 3
Mother Board
Expansion
Interface Card x 3
Mother Board
Mother Board
408M : Trunk x 4, Extension x 8
Expansion KSU (1632ME-A) x 3
Main KSU (1632M-A)
Expansion Interface Card
408E : Trunk x 4, Extension x 8
008E : Extension x 8
(Optional 2BRIDB ISDN BRI x 4),
000E : Extension x 0
(Optional 2BRIDB ISDN BRI x 4)
1PRIU : ISDN PRI x 30
Figure 1-2 System Image
ISSUE 4.0 SL1000
Hardware Manual 1-11
3.2.1 Expandability of Trunk and Extension (without PRI)
(Trunk)
System Wide
Detail of one KSU
Example 1: 408 x 4
Example 2: 408 x 3, 2BRIDB x 1
48
32
16
16
12
8
4
16
12
8
4
1632M KSU
1632ME EXP
(1st Exp. KSU)
1632ME EXP
(2nd Exp. KSU)
1632ME EXP
(3rd Exp. KSU)
(Not trunk
support)
32 64 96 128
(Extension)
408M
408E or 008E
+ 2BRIDB
(1st opt. slot)
408E or 008E
+ 2BRIDB
(1st opt. slot)
408E or 008E
+ 2BRIDB
(1st opt. slot)
408M
1 KSU
1 KSU
408E or 008E
+ 2BRIDB
(2nd opt. slot)
408E or 008E
+ 2BRIDB
(2nd opt. slot)
408E or 008E
+ 2BRIDB
(3rd opt. slot: SLT only)
8 16 24
8 16 24
32
000E + 2BRIDB (3rd opt. slot)
000E + 2BRIDB (3rd opt. slot)
000E + 2BRIDB
(3rd opt. slot)
000E + 2BRIDB
(2nd opt. slot)
000E + 2BRIDB
(1st opt. slot)
000E + 2BRIDB (2nd opt. slot)
Example 3: 408 x 2, 2BRIDB x 3
16
12
8
4
408M
1 KSU
8 16
Example 4: 408 x 1, 2BRIDB x 3
16
12
8
4
408M
1 KSU
8
Figure 1-3 Maximum KSU Capacity - Expandability of Trunk and Extension (without PRI)
SL1000 ISSUE 4.0
1-12 Introduction
3.2.2 Expandability of Trunk and Extension (with PRI)
(Trunk)
System Wide
Detail of one KSU
Example 1: 408 x 3, 2BRIDB x 2, PRI x 1
126
84
42
42
12
8
4
1632M KSU
1632ME EXP
(1st Exp. KSU)
1632ME EXP
(2nd Exp. KSU)
1632ME EXP
(3rd Exp. KSU)
(Not trunk
support)
24 48 72 96
(Extension)
408M
1 KSU
8 16 24
PRI
(3rd opt. slot)
Example 2: 408 x 1, 008 x 1, PRI x 1
34
4
408M
008E
(1st opt. slot)
1 KSU
8 16
PRI
(2nd opt. slot)
408E or 008E
+ 2BRIDB
(1st opt. slot)
408E or 008E
+ 2BRIDB
(2nd opt. slot)
Figure 1-4 Maximum KSU Capacity - Expandability of Trunk and Extension (with PRI)
ISSUE 4.0 SL1000
Hardware Manual 1-13
MEMO
SL1000 ISSUE 4.0
1-14 Introduction
Installation
SECTION 1 INSTALLING THE MAIN & EXPANSION KSUS
1.1 Before Installing the KSU(s)
1.1.1 General Precautions
To avoid shock or equipment damage, do not plug in or turn the system power on before completing
the installation process.
Avoid working with the Equipment during electrical storms.
Use only commercial AC power to prevent shock or fire.
Use the power cord supplied with the KSU.
Install batteries with the correct polarity to prevent damaging equipment.
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
Never touch uninsulated telephone wires or terminals unless the telephone line is disconnected at
the network interface.
To avoid damage, the KSU should not be placed on unstable surfaces.
To prevent overheating, do not bundle AC power cords together.
Make sure the KSU has proper Earth ground.
If Expansion KSU(s) are installed, turn the power on/off in the following order: Expansion 3 KSU,
Expansion 2 KSU, Expansion 1 KSU and then Main KSU
1.1.2 Preparations
Make sure the necessary tools (screw driver set, pliers set, etc) are available.
Make sure you have a building plan showing common equipment, extensions, the telecom
demarcation, and earth ground location. The installation site must meet the following site /
environmental requirements.
1.1.3 Site Requirements
Each Main or Expansion KSU(s) can have the optional Battery Box connected, before deciding on the
mounting location refer to Figure 2-4 Horizontal Arrangement of the KSUs on page 2-6 and
INSTALLING THE EXTERNAL BACKUP BATTERY on page 2-20.
The system without the IP4WW-Battery Box should be wall-mounted only. The system with the
IP4WW-Battery Box can be installed on either the floor or wall (horizontally). Ensure enough space
exists to allow the installation of additional KSU(s) and/or battery box.
A dedicated 100V-120V/220V/230V/240VAC circuit located within two meters of the KSU is
required. A separate dedicated AC outlet is necessary for each KSU.
Hardware Manual 2-1
I
n
s
t
a
l
l
a
t
i
o
n
2
1.1.4 Environmental Requirements
Meeting established environmental standards maximizes the life of the system. Make sure that the site
is not:
In direct sunlight or in hot, cold or humid places.
In dusty areas or in areas where sulfuric gases are produced.
In places where shocks or vibrations are frequent or strong.
In places where water or other fluids comes in contact with the equipment.
In areas near high-frequency machines or electric welders.
Near computers, telexes, microwaves, air conditioners, etc.
Near radio antennas (including shortwave).
1.1.5 Unpacking
Unpack the KSU and check it against the following list. Inspect for physical damage.
Table 2-1 KSU Packing List
Items List of Contents QTY
1632M-A KSU 1632M-A KSU 1
AC Power Cord (AC Power Cord is not attached for IP4[ ]-1632M-A KSU w/o
C type)
1
Manual CD 1
Screws (M4.1x25) 4
Wall-Mounting Template 1
1632ME-A EXP 1632ME-A EXP 1
AC Power Cord (AC Power Cord is not attached for IP4[ ]-1632ME-A EXP w/o
C type)
1
Screws (M4.1x25) 4
Expansion Cable 1
Wall-Mounting Template 1
1.2 Installing the Main KSU (1632M-A KSU)
The Main KSU has a CPU-A card, four trunks and eight hybrid extension Interface with one power
failure transfer circuit, and a control relay circuit for External devices. And three mounting space for
optional card (408E-A1/008E-A1/000E-A1/1PRIU-C1) are available.
When the IP4[ ]-MEMDB-C1 is installed into the CPU card, An Expansion KSU can be added
increasing system capacity. Each KSU (Main or Expansion) is powered by its own power supply.
SL1000 ISSUE 4.0
2-2 Installation
Sub-Cover
Tab
< Front view >
S1
J3
CPU card
E
X
P
3
E
X
P
2
V
O
I
P
L
A
N
V
O
I
P
E
X
P
1
E
X
P
3
L
O
A
D


S
E
R
I
A
L
E
X
P
2
E
X
P
1
Tab
Figure 2-1 CPU Card Location
Table 2-2 Items on the CPU card
Item Description
S1 (LOAD) Switch for System Restart/System Reset (Cold start occurs)/Upload Software
J3 (RJ45)
87654321
Ethernet Cable Connection (for SMDR (PC, Printer), PCPro or WebPro.etc)
Pin No. Connection
1 Tx+
2 Tx-
3 Rx+
4 -
5 -
6 Rx-
7 -
8 -
For the detail of LED (D1 - D5), refer to Figure 4-17 Inserting the CF Card on page 4-11 and
Table 4-2 CPU LED Indications on page 4-13.
1.3 Wall-Mounting the KSU(s)
1.3.1 KSU Dimensions
For Dimensions of the 1632M-A and 1632ME-A KSUs, refer to Figure 2-2 Dimension of the Main and
Expansion KSU on page 2-4.
ISSUE 4.0 SL1000
Hardware Manual 2-3
290 mm
(11.417)
115 mm
(4.528)
375 mm (14.764)
Figure 2-2 Dimension of the Main and Expansion KSU
1.3.2 Wall Installation of KSU
The Main KSU (1632M-A) and Expansion KSU(s) (1632ME-A) be mounted on the wall. Before
installing, ensure the appropriate spacing exists as shown below. In case of horizontal arrangement,
refer to Mounting one KSU on the Battery Box on page 2-33 for mounting on the IP4WW-Battery
Box.
SL1000 ISSUE 4.0
2-4 Installation
Minimum 200 mm (7.874)
for ventilation
Minimum 100 mm (3.937)
for ventilation and wiring
Minimum 100 mm (3.937)
for ventilation and wiring
Minimum 100 mm (3.937)
for ventilation and wiring
Minimum 300 mm (11.811) Minimum 300 mm (11.811)
Main KSU
EXP. KSU
EXP. KSU
EXP. KSU
Minimum 200 mm (7.874)
for wiring
Ceiling
Floor
Wall
Figure 2-3 Vertical Arrangement of KSUs
Due to the limit of extension cable length to connect Main KSU and Expansion KSU(s), the install
location of Main KSU and each Expansion KSU(s) must be considered as above or as the next figure.
When KSU is mounted on the Battery Box, it cannot be wall-mounted for vertically as above.
In the case, the KSU is mounted on Battery Box must be wall-mounted horizontally as shown on the
Figure 2-4 Horizontal Arrangement of KSUs on page 2-6.
ISSUE 4.0 SL1000
Hardware Manual 2-5
Minimum
100 mm
(3.937)
Minimum
100 mm
(3.937)
Minimum
100 mm
(3.937)
Minimum
300 mm
(11.811)
Minimum
300 mm
(11.811)
Ceiling
Floor
Wall
Minimum 200 mm (7.874)
for ventilation
Minimum 200 mm (7.874)
for ventilation
Main KSU EXP. KSU EXP. KSU EXP. KSU
Figure 2-4 Horizontal Arrangement of KSUs
Due to the limit of extension cable length to connect between Main KSU and Expansion KSU(s), the install
location of Main KSU and each Expansion KSU(s) must be considered as Figure 2-4 Horizontal
Arrangement of KSUs on page 2-6.
1.3.3 Mounting Procedure of KSU
One Main KSU or Expansion KSU(s) can be mounted per IP4WW-Battery Box. For the mounting, refer to
Mounting One KSU on the Battery Box on page 2-33.
1. Place the attached template on the wall to mark the four screw positions.
U
P
Template
Figure 2-5 Wall-Mounting Template
SL1000 ISSUE 4.0
2-6 Installation
2. Install four screws into the wall. The screw heads must stand off from the wall about 2.5 mm
(0.098) to 3.5 mm (0.138).
285 mm (11.221)
285 mm (11.221)
180 mm
(7.087)
2.5 mm (0.098) -
3.5 mm (0.138)
Figure 2-6 Screw Positions
Wall-Mounting Screws (M4.1x 25: 4 pcs) are attached to the KSU.
The screw diameter is 4 mm (0.158) to 4.5 mm (0.177).
3. Push the center of the Sub-Cover and slide it outward.
Sub-Cover
Figure 2-7 Sub-Cover Slide-out
ISSUE 4.0 SL1000
Hardware Manual 2-7
4. Pull out the Sub-Cover by pushing out the tabs.
Sub-Cover
Tab
Tab
Figure 2-8 Removing the Sub-Cover
The Sub-Cover can be opened and held in the open position.
Push to hold
Open
Figure 2-9 Sub-Cover Open Position
5. Align the four holes on the back of the KSU with the four screws installed in the wall.
Hook
Screw head
Screw head
Fasten screws
Figure 2-10 Mounting the KSU
6. Slide the KSU into position and tighten the lower two screws.
SL1000 ISSUE 4.0
2-8 Installation
1.4 Installing the Expansion KSU(s)
1.4.1 General
Each Expansion KSU is connected to the Main KSU individually. The EXIFB-C1 card and the
MEMDB-C1 card must be installed in the Main KSU (1632M-A) . (Refer to Installing the Expansion
Memory Card (MEMDB-C1) on page 2-60 for MEMDB-C1 card)
1.4.2 Unpacking (EXIFB-C1)
Unpack the EXIFB-C1 and check it against physical damage.
Table 2-3 EXIFB-C1 Packing List
Items List of Contents QTY
EXIFB-C1 EXIFB-C1 PCB 1
1.4.3 Connectors Location (EXIFB-C1)
J4
J6 J5
J1
J2
J3
Figure 2-11 Connectors of EXIFB-C1
Table 2-4 Connectors of EXIFB-C1
No. Connectors Connectable Devices
J1 Expansion Connector Expansion KSU 3
J2 Expansion Connector Expansion KSU 2
J3 Expansion Connector Expansion KSU 1
J4 Mother PCB J1 connector on 408M-A1
J5, J6 Debug Purpose (Not used) -
1.4.4 Installing the EXIFB-C1 PCB
Do Not Power on until all installations have been completed.
1. Turn off the system power and disconnect the AC cord from KSU.
ISSUE 4.0 SL1000
Hardware Manual 2-9
2. Open and pull out the Sub-Cover of the Main KSU.
Sub-Cover
Sub-Cover
Tab
Tab
Figure 2-12 Removing the Sub-Cover
3. Loosen two screws and pull out the Main-Cover by pressing the two hooks.
Two screws
Hooks
Main-Cover
Figure 2-13 Removing the Main-Cover
SL1000 ISSUE 4.0
2-10 Installation
4. Press tab A and lift the CPU support bracket.
CPU support
CPU support
EXIFB-C1 PCB
408M-A1 at 1632M KSU
J1
A
Figure 2-14 EXIFB-C1 PCB Installation
5. Insert the EXIFB-C1 PCB into the J1 connector on the 408M-A1 at 1632M-A KSU.
6. Close the CPU support and make sure the tab A locks into place.
7. Cut and remove the Plastic Knockouts as needed for Expansion KSU.
Main-Cover
Plastic Knockouts
Figure 2-15 Removing the Plastic Knockouts
8. Replace the Main-Cover and fasten two screws.
Two screws
Hooks
Main-Cover
Figure 2-16 Replacing the Main-Cover
ISSUE 4.0 SL1000
Hardware Manual 2-11
1.4.5 KSUs Inter-connection
1. Connect the Main KSU (1632M-A) and Expansion KSU (1632ME-A) using the cables attached to
the Expansion KSU.
Exp. KSU No.1 (1632ME-A)
Exp. KSU No.2 (1632ME-A)
Main KSU (1632M-A)
< Bottom View >
< Bottom View >
Exp. KSU No.3 (1632ME-A)
< Bottom View >
< Front View >
< Bottom View >
EXIFE-C1 PCB
CPU card
EXIFE-C1 PCB
EXIFE-C1 PCB
EXIFB-C1 PCB
EXP 3
EXP 2
EXP 1
E
X
P
L
A
N
E
X
P
E
X
P
Figure 2-17 Connection of KSUs
Use attached cables for the above inter-connection.
Because of cable length, KSU positioning is limited.
1.5 Grounding and AC Cabling
The ETH (Earth Ground Lug) is located near the power supply on each KSU. The Sub-Cover must be
opened in order to access to it.
SL1000 ISSUE 4.0
2-12 Installation
1.5.1 Grounding the KSU
Ensure all Main and Expansion KSU(s) are powered off and unplug the AC
cord.
In each KSU, connect the ETH lug to the verified grounding point using a minimum cable size of
14AWG (2.0 mm) wire.
ETH Lug
To Earth
Screw
Figure 2-18 ETH Lug
The grounding cable is supplier-provided.(not attached to the system)
1. Loosen the screw.
2. Insert a grounding wire (user supplied).
3. Tighten the screw.
4. Connect the grounding wire to earth ground.
Proper grounding is very important to protect the system from external
noise and to reduce the risk of electrocution in the event of a lightning
strike.
1.5.2 AC Power Requirement
A dedicated 100V-120V/220V/230V/240V 50/60Hz circuit located within two meters of the KSU is
required. A separate dedicated AC outlet is necessary for each KSU.
Double Pole/Neutral Fusing
(Power supply fuses are located at both the L and N side.)
Table 2-5 Power Requirement
110 VAC 220 VAC 230 VAC 240 VAC
Power Require-
ments
110 VAC@15 A 220 VAC@15 A 230 VAC@15 A 240 VAC@15 A
Power Con-
sumption
Main KSU = 144 VA
4 KSU Total = 576 VA
Main KSU = 172 VA
4 KSU Total = 688 VA
Main KSU = 175 VA
4 KSU Total = 700 VA
Main KSU = 175 VA
4 KSU Total = 700 VA
Input Voltage
(Rated Voltage)
90 VAC to 264 VAC (100VAC/120VAC/220VAC/230VAC/240VAC)
Frequency 47 Hz - 63 Hz (Rated Frequency:50/60 Hz)
Phase and Wire Single Phase, 2 Line + PE Type
Grounding Re-
quirement
No.14 AWG Copper Wire
ISSUE 4.0 SL1000
Hardware Manual 2-13
110 VAC 220 VAC 230 VAC 240 VAC
Feeding Volt-
age
SLT: 20 mA/-27 V
AC Input I Main KSU = 1.31 A
4 KSU Total = 5.24 A
Main KSU = 0.78 A
4 KSU Total = 3.12 A
Main KSU = 0.76 A
4 KSU Total = 3.04 A
Main KSU = 0.73 A
4 KSU Total = 2.92 A
KWh Main KSU = 0.144 KWh
4 KSU Total = 0.576
KWh
Main KSU = 0.172 KWh
4 KSU Total = 0.688
KWh
Main KSU = 0.175 KWh
4 KSU Total = 0.700
KWh
Main KSU = 0.175 KWh
4 KSU Total = 0.700
KWh
BTU
(KWhx3413)
Main KSU = 491 BTU
4 KSU Total = 1964 BTU
Main KSU = 587 BTU
4 KSU Total = 2348 BTU
Main KSU = 597 BTU
4 KSU Total = 2388 BTU
Main KSU = 597 BTU
4 KSU Total = 2388 BTU
1.5.3 AC Power Cord
The AC power switch and AC power inlet are located at the left side of each KSU. The AC power cord
is connected to the AC inlet and the commercial AC power socket.
Do not plug-in AC power cord if the KSU Cover is removed.
Before connecting the AC power cord, make sure:
The power switch at the left side of each KSU is turned OFF.
The power switch at the commercial AC power socket is turned OFF.
The AC plug fits the commercial AC power socket. The plug adapter is
necessary if it does not fit.
Connect
AC Power Cord
KSU
To Commercial
AC Power Socket
B type
Figure 2-19 AC Power Cord
Each KSU must have its own commercial AC power socket.
DO NOT POWER ON until all KSU installation has been completed.
1.6 Trunk/Extension Cabling
1.6.1 General
The system provides RJ11 modular jacks for analog trunk and extension connections.
SL1000 ISSUE 4.0
2-14 Installation
1.6.2 Precautions for Cabling
Do not wire the cable with an AC cable, computer, etc.
Do not run the cable near a high frequency generating device.
Use cable protectors in case the cables are run on the floor.
Aerial distribution wiring is not allowed.
Trunks must be installed with lightning protectors.
Do not install the Topaz Terminal in the SL1000 system, it does not work properly.
1.6.3 Trunk Cabling
Ensure all Main and Expansion KSU(s) are powered off and unplug the AC
cord.
1. Open the Sub-Cover.
Push to hold
Open
Sub-Cover
Figure 2-20 Sub-Cover Open and Hold
ISSUE 4.0 SL1000
Hardware Manual 2-15
2. Insert the modular plugs of the trunk line cords into the analog trunk modular jacks on the system.
Wire Position for each Port
Modular Plug
Trunk Port Position
CO2 or Audio in/out
(External paging)
CO3 or Audio in
(External MOH)
CO4 or Audio in
(BGM)
CO1 CO2 CO3 CO4
T R
T: Tip
R: Ring
Figure 2-21 Trunk Cabling
The lightning protectors MUST BE INSTALLED on a trunk.
Unused CO port (CO2 to CO4) can be used for Audio port (External paging, External MOH or
BGM).
The program setting must be required when using Audio port instead of Trunk port in the system.
The External Paging can be set for 408M-A1 PCB at each KSU.
The External MOH and BGM can be set only one port for each External source in the system.
Using a single port, Trunk port and Audio port can not be used at the same time.
Doorphone box can not be used on the Trunk port.
1.6.4 Extension Cabling
Before plugging in the Multiline Telephone, DSS Console, Single line
Telephone, Doorphone or External Sensor Device, ensure all Main and
Expansion KSUs are powered off.
Topaz Terminal does not work properly when it connected.
1. Open the Sub-Cover.
SL1000 ISSUE 4.0
2-16 Installation
2. Insert the modular plugs of the extension line cords (2-wire/4-wire) into the extension modular
jacks on the KSU.
6 5

ST8 ST6 or ST7
T
L
R
H L
T R
ST6 or ST7
T R T R
H
Multiline
Telephone
DSS Console Doorphone External
Sensor Device
SLT
Modular Cable
(4-wire, Straight)
Modular Cable
(2-wire, Straight)
KTS, DSS
SLT
Doorphone
300 m (984.3 ft)
1,125 m (3,691 ft)
150 m (492.1 ft)
Wire Position for each Port Extension Port Position
ST1 ST2 ST8
ST6 or Doorphone/Sensor
T : Tip
R : Ring
H : High
L : Low
ST7 or Doorphone/Sensor
T R
L H
Modular
Plug
T: Tip
R: Ring
H: High
L: Low
Max cable length
(24AWG 0.5 mm)
Figure 2-22 Extension Cabling
While an Analog Telephone (port) is ringing or MW-lamp is flashing on an
Analog Phone (port), do not disconnect the phone from the port or connect
another type of the terminal to this port.
DSS Console must be connected to the LAST PORT.
Doorphone/External Sensor Device must be connected to the No. 6 or 7 PORT of each 408M-A1.
The program setting is required when connecting a Doorphone/External Sensor Device.
1.6.5 Power Failure Transfer
1.6.5.1 General
In the event of AC power failure, the specified trunks are directly connected to the specified extension
ports as below. And SLT must be connected to the specified extension. The multiline telephone (4W)
does not work when connected to the specified extension port.
ISSUE 4.0 SL1000
Hardware Manual 2-17
Trunk Port No. 1 Extension Port No. 8
The connected extension must be SLT (Single Line Telephone).
Hardware switch (J6) must be set from "KT" to "PF" side (default: KT) when use the Power failure
transfer circuit.
Refer to Power Failure Transfer on page 2-58 for Power Failure Transfer of 408E-A1.
1.6.5.2 Power Failure Setting
1. Use Needle-nose pliers to change the switch position of "J6" from "KT" to "PF" as below.
(Default: KT)
J6
PF
Port
KT PF KT PF
Multiline
Telephone
PF
Port
Multiline
Telephone
Figure 2-23 PF/KT Switch of 408M-A1
2. Connect a SLT to the extension port No. 8.
SL1000 ISSUE 4.0
2-18 Installation
1.6.6 Cable Routing and Clamping
1. Depending on cabling requirement, select either a right or left route. Clamp and route cable to
outside.
Cables
Cable clamp
Figure 2-24 Cabling
2. Cut and remove the Plastic Knockouts as needed from the Sub-Cover.
Sub-Cover
Plastic Knockouts
Figure 2-25 Sub-Cover
3. Replace the Sub-Cover.
ISSUE 4.0 SL1000
Hardware Manual 2-19
SECTION 2 INSTALLING THE EXTERNAL BACKUP BATTERY
2.1 General
The external backup battery box (IP4WW-Battery Box) with batteries provides power to the system
when AC power fails. It is connected to the power supply of each KSU.
An optional (locally procured), external battery source can be used to provide power during a power
failure.
Each KSU must have own IP4WW-Battery Box.
To avoid damage to equipment, do not install the Topaz Battery Box
(DX2E-32i/NX7E Battery Box) to the SL1000 system.
2.2 Unpacking
Unpack the IP4WW-Battery Box and check it against the following list. Inspect for physical damage.
Table 2-6 IP4WW-Battery Box Packing List
Items List of Contents QTY
IP4WW-Battery Box Battery Box 1
Battery Connection Cable (Black & Red) 1
Battery Connection Cable (Blue) 1
Screws: M4 x 8
M3 x 6 with Washer
Screws: M4.1 x 16
10
1
6
Battery Box FM/WM Base-F
Battery Box FM/WM Base-R
1
1
Battery Box WM Support
Battery Box WM Hook
1
1
SL1000 ISSUE 4.0
2-20 Installation
2.3 Battery Box Dimensions
340 mm
(13.386)
230 mm
(9.055)
500 mm (19.685)
Figure 2-26 Dimension of the IP4WW-Battery Box
2.4 Battery Specifications
Table 2-7 Battery Specifications
Item Data
Capacity 12 V, 7.0 Am/H or equivalent (Voltage must be 12 V)
Recommended Battery GS Yuasa NP7-12 (151 x 65 x 97.5 mm / 2.7 kg)
<GS Yuasa International LTD.>
The Battery must be UL recognized product.
Number of Batteries (per Box) 2
Backup Duration (Estimated) 1 hour
2.5 Battery Installation
Before floor-mounting or wall-mounting the IP4WW-Battery Box, the batteries must be installed into
the IP4WW-Battery Box.
ISSUE 4.0 SL1000
Hardware Manual 2-21
1. Loosen two screws and remove the Front Cover.
Front Cover
Two screws
(with stopper)
Figure 2-27 Removing the Front Cover
2. Disconnect the Battery Connection Cable from the Fuse Unit if the cable is plugged already.
Battery Connection Cable
Fuse Unit
Figure 2-28 Disconnect Battery Connection Cable
SL1000 ISSUE 4.0
2-22 Installation
3. Loosen the screw and lift the Batt Stopper.
Screw
Batt Stopper
Figure 2-29 Batt Stopper
4. Pull out the Battery tray.
Battery tray
Figure 2-30 Pulling out the Battery Tray
5. Loosen two screws and remove the Battery tray cover.
ISSUE 4.0 SL1000
Hardware Manual 2-23
6. Remove two screws and remove the Battery tray bracket.
Two screws
(M3 X 8)
Two screws
(with stopper)
Battery tray cover
Battery tray bracket
Figure 2-31 Remove the Battery Tray Bracket
7. Install two batteries into the Battery tray.
Two screws
(M3 X 8)
Two batteries
Battery tray bracket
Figure 2-32 Battery Installation
SL1000 ISSUE 4.0
2-24 Installation
8. Connect the battery cables.
Terminal
(black)
Terminal
(black)
< Front View >
Terminal
(red)
Terminal
(red)
Battery Connection
Cable (blue)
Battery Connection Cable (black)
Battery Connection
Cable (red)
Two batteries
Figure 2-33 Connecting the Battery Cables
Incorrect installation of batteries may damage the Fuse Unit or cause
possible fire.
9. Insert Battery Connection Cable into the Cable guides as shown in the next diagram.
10. Install the Battery tray cover aligning the three tabs and tightening the two screws.
Two screws
(with stopper) Three tabs
Battery tray cover
Battery
Connection Cable
Cable guides
Figure 2-34 Installation of Battery Tray Cover
Do not pull the Battery connection cable strongly.
Be careful not to catch the Battery Connection Cable when installing the
Battery tray cover.
Write down the year and month of the next battery replacement in the label on Front cover.
ISSUE 4.0 SL1000
Hardware Manual 2-25
11. Insert the Battery tray into the Battery Box.
Battery tray
Figure 2-35 Inserting the Battery Tray
12. Set the Batt Stopper bracket in place and secure with screw.
Screw
Batt Stopper
Figure 2-36 Secure Batt Stopper Bracket
SL1000 ISSUE 4.0
2-26 Installation
13. Plug the Battery Connection Cable into the Fuse unit.
Fuse unit
Battery Connection
Cable
Figure 2-37 Connecting the Battery Connection Cable
14. Align tabs a to f to holes A to F on Battery Box. Slide the Front cover and tighten the two screws.
b
a
A
B
C
D
E
F
c
d
e
f
Front cover
Two screws
(with stopper)
Figure 2-38 Installation of Front Cover
2.6 Mounting the IP4WW-Battery Box
The IP4WW-Battery Box can be installed on either the floor or wall. One KSU can be mounted on an
IP4WW-Battery Box.
2.6.1 Floor-Mounting the IP4WW-Battery Box
Battery box can be mounted on the floor using the FM/WM Base-F, FM/WM Base-R and WM Support.
(Note: FM = Floor-Mount and WM = Wall-Mount)
ISSUE 4.0 SL1000
Hardware Manual 2-27
1. Assemble the FM/WM Base-F, Base-R and WM Support.
WM Support
FM/WM Base-R
FM/WM Base-F
Figure 2-39 Bases and Support of the Battery Box
2. Refer to Figure 2-40 Floor-Mount Spacing Guide on page 2-28 for required spacing before
drilling holes for 10 mm (0.394) anchor bolts (locally procured).
Mark and drill the four holes required to install the FM/WM Base.
3. Using anchor bolts, secure the FM/WM Base to the floor.
Four Anchor bolts
M10 mm (0.394)
Front side
: Maintenance space
Wall
1
5
0

m
m
(
5
.
9
0
6

)
4
6
0

m
m

(
1
8
.
1
1
0

)
AC inlet
side
5
0
0

m
m

(
1
9
.
6
8
5

)
1
9
0

m
m
(
7
.
4
8
0

)
Anchor bolt location
Figure 2-40 Floor-Mount Spacing Guide
SL1000 ISSUE 4.0
2-28 Installation
4. Using the four hooks on the FM/WM Base mount the IP4WW-Battery Box on the Base.
Hooks
IP4WW-Battery Box
Hooks
FM/WM Base
Figure 2-41 Mounting the Battery Box
5. Using four supplied screws, secure the IP4WW-Battery Box to the FM/WM Base.
Two Screws
(M4 X 8)
Two Screws
(M4 X 8)
IP4WW-Battery Box
FM/WM Base
Figure 2-42 Securing the Battery Box
2.6.2 Wall-Mounting the IP4WW-Battery Box
When wall-mounting the IP4WW-Battery Box, ensure the wall can support the
weight of the Battery Box (Total weight=17.6 kg (620.75 oz) - Including 2-
batteries, cord, KSU, etc). The Battery Box is secured to the wall using the
FM/WM BASE. Ensure that enough space is available to allow the installation
of additional KSU.
ISSUE 4.0 SL1000
Hardware Manual 2-29
Plywood should first be installed on the wall where the Battery Box will be positioned. This allows secure
anchoring of the screws which support the weight of the Battery Box.
1. Using four supplied screws, secure the WM Support to the FM/WM Base-F and Base-R.
Four Screws
(M4 X 8)
WM Support
FM/WM Base-R
FM/WM Base-F
Figure 2-43 Assemble Battery Box Base
2. Refer to Figure 2-44 Wall-Mount Spacing Guide on page 2-31 for required spacing before drilling
holes for 10 mm anchor bolts (locally procured).
Mark and drill the four holes required to install the FM/WM Base.
SL1000 ISSUE 4.0
2-30 Installation
3. Using anchor bolts, secure the FM/WM Base to the wall.
: Maintenance space
Anchor bolt location
Anchor bolt location
Four Anchor bolts
M10 mm (0.394)
1
5
0

m
m
(
5
.
9
0
6

)
3
4
3

m
m

(
1
3
.
5
0
4

)
5
0
0

m
m

(
1
9
.
6
8
5

)
4
6
0

m
m

(
1
8
.
1
1
0

)
Front side
Wall
AC inlet
side
Figure 2-44 Wall-Mount Spacing Guide
ISSUE 4.0 SL1000
Hardware Manual 2-31
4. Loosen two screws and remove the Front Cover.
Front Cover
Two screws
(with stopper)
Figure 2-45 Removing the Front Cover
5. Using the four hooks on the FM/WM Base mount the IP4WW-Battery Box to the Base.
IP4WW-Battery Box
Square hole
Hooks
Hooks
A
a
b
c
d
B
C
D
Figure 2-46 Mounting the Battery Box
SL1000 ISSUE 4.0
2-32 Installation
6. Using one supplied screw (M3x6 with washer), secure the back plane of the Battery Box to the
FM/WM Base.
Two screw holes
(Use either one)
< Front view>
Figure 2-47 Securing the Battery Box
2.6.3 Mounting One KSU on the Battery Box
Before wall-mounting or floor-mounting the IP4WW-Battery Box, a single KSU can be mounted on the
Battery Box.
1. Loosen two screws and remove the Front Cover of the Battery Box.
Front Cover
Two screws
(with stopper)
Figure 2-48 Removing the Front Cover
ISSUE 4.0 SL1000
Hardware Manual 2-33
2. Loosen two screws and remove the L-Bracket.
Two screws
(M4 X 8)
L-Bracket
Figure 2-49 Removing the L-Bracket
3. Turn the L-Bracket upside down.
Rotate the L-Bracket 180 degrees so that the upper FACE as shown in Figure 2-49 Removing the
L-Bracket on page 2-34 is located at the bottom as shown in Figure 2-50 Securing the L-Bracket
and WM Hook on page 2-35.
4. Insert tabs on Battery Box into holes on L-Bracket.
Secure the L-Bracket to the Battery Box using two screws.
5. Using two screws (M4x8), secure the WM Hook to the L-Bracket.
SL1000 ISSUE 4.0
2-34 Installation
6. Using two anchor bolts (locally procured), secure the WM Hook to the wall.
The WM Hook is required for securing both Floor-mount and Wall-mount cases.
Two screws
(M4 X 8)
Two screws
(M4 X 8)
Anchor Bolts
L-Bracket
WM Hook
Figure 2-50 Securing the L-Bracket and WM Hook
7. Install four screws into the L-Bracket (Do not tighten). A space of 2.5 mm (0.098) to 3.5 mm
(0.138) for KSU mounting is required. Mount the KSU on the screw heads.
Four Screws
(M4 X 8)
Four holes
KSU
A
B
D
C
a
b
c
d
Figure 2-51 Attaching the KSU
ISSUE 4.0 SL1000
Hardware Manual 2-35
8. Hold open the Sub-Cover of the KSU, and fasten two screws to mount the KSU.
Sub-Cover
Two screws
Figure 2-52 KSU Mounting on Battery Box
2.7 IP4WW-Battery Box to KSU Connection
To avoid damage to equipment, do not install the Topaz Battery Box
(DX2E-32i/NX7E Battery Box) to the SL1000 system.
Make sure the system power is off.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main
KSU.
1. Power off the KSU and disconnect AC cord.
2. Open the Sub-Cover of the KSU.
Push to hold
Open
Sub-Cover
Figure 2-53 Sub-Cover Open and Hold
SL1000 ISSUE 4.0
2-36 Installation
3. Cut and remove Plastic Knockout from the Sub-Cover to connect Battery cable.
Plastic
Knockout
Battery cable
Sub-Cover
Figure 2-54 Connecting Battery Cable
4. Connect Battery cable from the Battery box to Battery connector on the KSU.
2.8 IP4WW-Battery Box Fuse Replacement
In the event of a blown fuse correct the fault causing the fuse to blow before
replacing the fuse; otherwise you may cause fire or electrical hazards.
Be sure to use only the specified fuse (250VT8AL).
Be sure to install the fuse into the correct location.
Be careful not to burn yourself on the heated fuse. The blown fuse may be
heated soon after blowing.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main
KSU.
1. Power off the KSU and disconnect AC cord.
ISSUE 4.0 SL1000
Hardware Manual 2-37
2. Loosen two screws and remove the Front Cover.
Front Cover
Two screws
(with stopper)
Figure 2-55 Removing the Front Cover
3. Disconnect the Battery connection cable from the Fuse Unit.
Battery Connection Cable
Fuse Unit
Figure 2-56 Disconnecting the Battery Connection Cable
SL1000 ISSUE 4.0
2-38 Installation
4. Loosen the screw from the Fuse Unit.
Screw
Fuse Unit
Figure 2-57 Loosen the Fuse Unit Screw
5. Slide Fuse Unit out of the Battery box.
6. Replace the fuse (250VT8AL).
250VT8AL
Fuse
Fuse Unit guide
Fuse Unit
Figure 2-58 Replacing the Fuse
7. Using the Fuse Unit guides, slide the Fuse Unit into the Battery Box.
Fuse Unit guide
Fuse Unit
Figure 2-59 Install the Fuse Unit
ISSUE 4.0 SL1000
Hardware Manual 2-39
8. Secure the Fuse Unit by tightening the screw.
Screw
Fuse Unit
Figure 2-60 Securing the Fuse Unit
9. Reconnect the Battery Connection Cable to the Fuse Unit.
Battery Connection Cable
Fuse Unit
Figure 2-61 Connect Battery Connection Cable
SL1000 ISSUE 4.0
2-40 Installation
10. Align tabs a to f to holes A to F on Battery Box. Slide the Front Cover into position and tighten the
two screws.
b
a
A
B
C
D
E
F
c
d
e
f
Front cover
Two screws
(with stopper)
Figure 2-62 Installation of the Front Cover
ISSUE 4.0 SL1000
Hardware Manual 2-41
SECTION 3 INSTALLING THE EXPANSION INTERFACE CARDS
3.1 General
Up to three expansion interface cards can be installed per KSU.
Table 2-8 Expansion Cards
Expansion Interface
Card
Description Note
IP4WW-408E-A1 4 analog trunks and 8 hybrid extensions card
IP4WW-008E-A1 8 hybrid extensions card
IP4WW-000E-A1 0 trunk/extension card for ISDN BRI
IP4WW-2BRIDB-C1 2 Euro-ISDN BRI daughter board (Mount on the 008E-A1 or 000E-A1)
IP4WW-1PRIU-C1 1 Euro-ISDN PRI (E1 for Latin America) card
The 408E-A1, 2BRIDB-C1 or 1PRIU-C1 should not be installed into the 3rd
Expansion KSU. The 3rd Expansion KSU does not support any trunks.
The function of IP4WW-000E-A1 card is just a mounting card for the 2BRIDB.
The 2BRIDB-C1 can be installed in following combinations;
Daughter Board
Option Unit
408M-A1 408E-A1 008E-A1 000E-A1
2BRIDB-C1 No No Yes Yes
3.2 Unpacking
Unpack the 408E-A1/008E-A1/000E-A1/2BRIDB-C1/1PRIU-C1 and check it against the following list.
Inspect for physical damage.
Table 2-9 Expansion Card Packing List
Items List of Contents QTY
IP4WW-408E-A1 408E-A1 PCB (with PKG Spacer) 1
Nylon Spacers 2
Metal Spacers 2
Screws (with circular washer) 2
IP4WW-008E-A1 008E-A1 PCB (with PKG Spacer) 1
Nylon Spacers 2
Metal Spacers 2
Screws (with circular washer) 2
IP4WW-000E-A1 000E-A1 PCB (with PKG Spacer) 1
Nylon Spacers 2
Metal Spacers 2
Screws (with circular washer) 2
SL1000 ISSUE 4.0
2-42 Installation
Items List of Contents QTY
IP4WW-2BRIDB-C1 2BRIDB-C1 PCB 1
Nylon Spacers 2
2BRI Label 1
Metal Spacers 1
Screws (with circular washer) 2
IP4WW-1PRIU-C1 1PRIU-C1 PCB (with PKG Spacer) 1
Nylon Spacers 2
Metal Spacers 2
Screws (with circular washer) 2
3.3 Mounting the Expansion Interface Card
DO NOT POWER ON until all installation has been completed.
Fit the optional 2BRIDB-C1 daughter boards before installing the 000E-A1/008E-A1 PCBs. Set the
switches on the 2BRIDB-C1 board before mounting it onto the 000E-A1/008E-A1 PCB.
3.3.1 Mounting the 408E-A1/008E-A1/000E-A1/1PRIU-C1 PCBs
The procedure for mounting the expansion interface cards is as follows;
Do Not Power on until all installation have been completed.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main
KSU.
1. Turn off the system power and disconnect the AC cord from KSU.
2. Open and remove the Sub-cover.
Sub-Cover
Sub-Cover
Tab
Tab
Figure 2-63 Removing the Sub-cover
ISSUE 4.0 SL1000
Hardware Manual 2-43
3. Loosen two screws and remove the Main-cover.
Two screws
Hooks
Main-Cover
Figure 2-64 Removing the Main-cover
4. Insert two Nylon-spacers into the specified holes, and fasten two Metal-spacers into the specified
holes. (Both Nylon and Metal spacers are provided with 408E/008E/000E/1PRIU)
If no more Expansion Interface cards are to be mounted on the 1st PCB, fasten two screws to
secure the 1st PCB on the top of the 408E/008E/000E/1PRIU.
Expansion Interface Card
(1st PCB)
J2
J1
Nylon-Spacers
Metal-Spacers
Screw position
1st EXP.
PCB
Both sides are
the same.
Screws
Figure 2-65 Mounting of the 1st Expansion Interface Card
SL1000 ISSUE 4.0
2-44 Installation
5. In case a 2nd PCB is mounted, insert two Nylon-spacers into the specified holes, and fasten two
Metal-spacers into the specified holes. (Both Nylon and Metal spacers are provided with 408E/
008E/000E/1PRIU)
If no more Expansion interface card is mounted on the 2nd PCB, fasten two screws to secure the
2nd PCB to the top of the 408E/008E/000E/1PRIU.
Expansion Interface Card
(2nd PCB)
J1
J2
Nylon-Spacers
Metal-Spacers
Screws
Expansion Interface Card
(1st PCB)
Screw position
Both sides are
the same.
2nd EXP.
PCB
Figure 2-66 Mounting the 2nd Expansion Interface Card
ISSUE 4.0 SL1000
Hardware Manual 2-45
6. In case a 3rd PCB is mounted, insert two Nylon-spacers into the specified holes, and fasten two
Metal-spacers into the specified holes. (Both Nylon and Metal spacers are provided with 408E/
008E/000E/1PRIU)
Fasten two screws to secure the 3rd PCB to the top of the 408E/008E/000E/1PRIU.
Expansion Interface Card
(3rd PCB)
Nylon-Spacers
Metal-
Spacers
Screws
Expansion Interface Card
(2nd PCB)
Screw position
Both sides are
the same.
EXP.3rd
PCB
J1
J2
J2
J2
J1
Figure 2-67 Mounting the 3rd Expansion Interface Card
7. Following illustration shows an example for installing 3 expansion PCBs onto the KSU.
3rd PCB
2nd PCB
1st PCB
Figure 2-68 Mounting Three Expansion Interface Cards
SL1000 ISSUE 4.0
2-46 Installation
8. Cut and remove the Plastic Knockouts as required for each Expansion interface card.
Main-Cover
Plastic
Knockouts
EXP.1st PCB
EXP.2nd PCB
EXP.3rd PCB
Figure 2-69 Plastic Knockouts
9. Replace the Main-cover and fasten two screws.
Two screws
Hooks
Main-Cover
Figure 2-70 Replacing the Main-cover
3.3.2 Mounting the 2BRIDB PCB
Set the switches on the 2BRIDB-C1 PCB before mounting onto the 008E-
A1/000E-A1 PCB, refer to the Switch Setting on page 2-53.
ISSUE 4.0 SL1000
Hardware Manual 2-47
1. Cut and remove specified Plastic Knockouts on the 008E-A1/000E-A1 PCB.
008E-A1
000E-A1
Plastic Knockout
Plastic Knockouts
Figure 2-71 Plastic Knockouts on 008E-A1/000E-A1
2. Insert two Nylon-spacers into the specified holes. Using supplied screw, fasten Metal Spacer to
2BRIDB-C1 PCB.
3. Mount the 2BRIDB-C1 PCB onto the 008E-A1/000E-A1 PCB using two Nylon-spacers and one
screw. (Refer to Figure 2-72 Installing the 2BRIDB-C1 on page 2-48)
4. Attach the 2BRI Label to the specified position on the 008E-A1/000E-A1 PCB.
008E-A1/000E-A1 PCB
Nylon-Spacers
J3
J1
Metal-Spacer
2BRI Label
2BRIDB-C1 PCB
Screw
Screw
Figure 2-72 Installing the 2BRIDB-C1
The 2BRIDB-C1 cannot be mounted on the 408M-A1/408E-A1/1PRIU-C1 PCB.
SL1000 ISSUE 4.0
2-48 Installation
5. Mount the 2BRIDB-C1 with 008E-A1/000E-A1 PCB into the KSU.
008E-A1/000E-A1 PCB
and 2BRIDB-C1 PCB
Nylon-
Spacers
J1
Metal-Spacers
J2
Screws
Figure 2-73 Mounting the 2BRIDB-C1 into the KSU
6. Replace the Main-Cover and fasten two screws.
Two screws
Hooks
Main-Cover
Figure 2-74 Replacing the Main-Cover
3.4 Cabling and Setting the Expansion Interface Card
Precautions for Cabling
Do not wire the cable with an AC cable, computer, etc.
Do not run the cable near the high frequency generating device.
ISSUE 4.0 SL1000
Hardware Manual 2-49
Use cable protectors in case the cables run on the floor.
Aerial distribution wiring is not allowed.
Trunks must be installed with lightning protectors.
Do not install the Topaz Terminal in the SL1000 system, it does not work properly.
3.4.1 Cabling IP4WW-408E-A1
This IP4WW-408E-A1 PCB provides four RJ11 connections for analog trunks and eight RJ11
connections for hybrid extensions.
Before plugging in the Multiline Telephone, DSS Console, Single line
Telephone or Doorphone, ensure all Main and Expansion KSUs are powered
off.
Topaz Terminal does not work properly when it connected.
SL1000 ISSUE 4.0
2-50 Installation
6 5

J5
Trunk Port
J4
Extension Port
CO8 ST16 ST9 1st EXP. PCB
ST24 ST17 2nd EXP. PCB
ST32 ST25 3rd EXP. PCB
CO12
CO16
CO5
CO9
CO13
Wire Position
for each Port
Extension Port Position
ST25
ST17
ST9
ST32
ST24
ST16
CO8/12/16 CO6/10/14
CO7/11/15 CO5/9/13
T
L H
R
T
L H
L H
R
T R
Wire Position
for each Port
Extension Port Position
T R
T R
Modular Cable
(4-wire, Straight)
ST16, ST24
From MDF Block
or Modular Jacks
(from Telecom)
Multiline
Telephone
DSS Console SLT
Modular Cable
(2-wire, Straight)
Figure 2-75 Connectors of 408E-A1
Only Analog Telephones can be connected when this PCB is installed as the 3rd PCB in each Main or
Expansion KSU. Multiline Telephones and DSS Console must not be connected.
3.4.2 Cabling IP4WW-008E-A1
This IP4WW-008E-A1 PCB provides eight RJ11 connections for hybrid extensions.
Before plugging in the Multiline Telephone, DSS Console, Single line
Telephone or Doorphone, ensure all Main and Expansion KSUs are powered
off.
ISSUE 4.0 SL1000
Hardware Manual 2-51
Topaz Terminal does not work properly when it connected.
6 5

J4
Extension Port
ST16
ST24
ST32
ST16, ST24
Wire Position
for each Port
Extension Port Position
ST25
ST17
ST9
ST32
ST24
ST16
T
L H
R
T
L H L H
R
T R
ST9 1st EXP. PCB
ST17 2nd EXP. PCB
ST25 3rd EXP. PCB
Modular Cable
(4-wire, Straight)
Multiline
Telephone
DSS Console SLT
Modular Cable
(2-wire, Straight)
Figure 2-76 Connectors of 008E-A1
Only Analog Telephones can be connected when this PCB is installed as the 3rd PCB in each Main or
Expansion KSU. Multiline Telephones and DSS Console must not be connected.
3.4.3 Cabling IP4WW-000E-A1
This IP4WW-000E-A1 PCB does not have any connector for cabling.
3.4.4 Cabling and Setting IP4WW-2BRIDB-C1
This IP4WW-2BRIDB-C1 PCB provides two RJ-61 BRI connections.
SL1000 ISSUE 4.0
2-52 Installation
J3
BRI2 BRI1
J2
ISDN BRI
Figure 2-77 Connectors of 2BRIDB-C1
3.4.4.1 Connectors
The following table shows the pin-outs for the RJ-61 cable connector for S-Bus and T-Bus
connections.
Table 2-10 RJ-61 BRI Pin-Outs (S-Bus, T-Bus)
Pin No. RJ-61 Cable Connec-
tor-2BRIDB-J2 (BRI1), J3
(BRI2) S-Bus Connection
RJ-61 Cable Connector-2BRIDB-
J2 (BRI1), J3 (BRI2) T-Bus Con-
nection
87654321
1 - -
2 - -
3 RA TA
4 TA RA
5 TB RB
6 RB TB
7 - -
8 - -
3.4.4.2 Switch Setting
Figure 2-78 Switches Location of 2BRIDB-C1 on page 2-54 shows the location of the connectors and
switches on the IP4WW-2BRIDB-C1.
ISSUE 4.0 SL1000
Hardware Manual 2-53
1. Set the switches J12 to J17 according to the system, referring the Table 2-11 Switch Setting of
2BRIDB-C1 on page 2-54.
Table 2-11 Switch Setting of 2BRIDB-C1
Switch No. Switch Position Description
J12/J15 ON (default) Termination register is ON.
This SW should be ON in case:
T-Bus Point-to-Point connection is selected.
T-Bus Point-to-Multipoint is selected, and if the system is Terminal 8.
(last device on the bus)
S-Bus.
OFF P-MP (Terminal 7)
J13, J14/J16, J17 T (default) T-Bus connection
S S-Bus connection
J12 & J15 do not configure the connection type on the system, they only add/remove the termination
of the circuit.
J13,J14 & J16, J17 do not configure the connection type on the system, they only select the polarity of
the connector J2/J3.
The 2BRIDB-C1 circuits must also be setup within the system configuration.
2. Connect the cables from the NT1 Network Termination cable to the J2 or J3 connector on the
2BRIDB-C1 daughter board.
Connector J2 - BRI1: Use switches J12, J13, J14
Connector J3 - BRI2: Use switches J15, J16, J17
Ensure that you set all switches correctly for each BRI circuit.
J3 J2
BRI 2 BRI 1
J12
J13 J14
J15
J16 J17
J12/15
ON OFF
J13/16
T S
J14/17
T S
IP4WW-2BRIDB-C1
Figure 2-78 Switches Location of 2BRIDB-C1
SL1000 ISSUE 4.0
2-54 Installation
3.4.5 Cabling and Setting IP4WW-1PRIU-C1
This IP4WW-1PRIU-C1 PCB provides one RJ-45 PRI connection.
PRI 1
J5
PRI/E1/T1 Line
Figure 2-79 Connector of 1PRIU-C1
3.4.5.1 Connector
Following table shows the pin-outs for the RJ-45 cable connector for S-Bus and T-Bus RJ-45
connections.
Table 2-12 RJ-45 PRI Pin-Outs (S-Bus, T-Bus)
Pin No. RJ-45 Cable Connector- PRI 1
(J5) S-Bus Connection
RJ-45 Cable Connector- PRI 1
(J5) T-Bus Connection
87654321
1 TA RA
2 TB RB
3 - -
4 RA TA
5 RB TB
6 - -
7 - -
8 - -
3.4.5.2 Switch Setting
The following figure shows the location of the switches and LEDs on the IP4WW-1PRIU-C1 Card.
1. Set the switches J6 to J9 according to the system, referring the Table 2-13 Switch Setting of
1PRIU-C1 on page 2-55.
Table 2-13 Switch Setting of 1PRIU-C1
Switch No. Switch Position Description
J6, J7 2M (default) Connect PRI/E1 (2.048 Mb/s) line
1.5M Connect PRI/T1 (1.544 Mb/s) line
J8, J9 T (default) T-Bus connection
S S-Bus connection
2. Connect the cables from the NT1 Network Termination cable to the J5 connector on the 1PRIU-
C1 Card.
ISSUE 4.0 SL1000
Hardware Manual 2-55
3. Assign whether the unit works as PRI/T1/E1 by PRG10-51-01.
With normal operation, D4 LED flashes green.

1.5M 2M
J6
J6
J7
J7
J8/9
J8 J9
J5
PRI 1
D3
(Red)
D3 D4
D4
(Green)
1.5M 2M
T
S
IP4WW-1PRIU-C1
Figure 2-80 Switches and LEDs Location of 1PRIU-C1
3.4.5.3 LED Indication
LED indications for the IP4WW-1PRIU-C1 are listed in following table. Each LED is listed with its
associated function and LED and operational status.
Table 2-14 LED Indication
LED Indication
Operation Status Remarks
Live LED (D4)
(Green)
Busy LED (D3)
(Red)
On On System Initializing -
Flash (1s) On The assignment of the unit is refused When you exceed the system ca-
pacity.
When the main software version
is not matched.
Flash (1s) Trouble found during self-diagnostics. -
Flash (100ms) On Normal Op-
eration
A Channel is busy (use another
from Ch1 - Chx)
-
Off All channels are Idle. -
SL1000 ISSUE 4.0
2-56 Installation
LED Indication
Operation Status Remarks
Live LED (D4)
(Green)
Busy LED (D3)
(Red)
Off On Unit Busy A Channel is busy (use another
from Ch1 - Chx)
-
Off All channels are Idle. -
Flash 80ms (On/
Off) x3/ 400ms
Off
Downloading firmware -
T1 Alarm Mode
Refer to following figure for LED pattern information. LED indications for the T1 are listed in
Table 2-15 T1 LED Indications on page 2-57.
LOS
red
120 ms
green
red
green
red
green
red
green
AIS
OOF
RAI
1 cycle 3.8 sec (120ms x 32=3840 ms)
Figure 2-81 1PRIU-C1 LED Indication Pattern of Layer 1 on T1 Unit
Table 2-15 T1 LED Indications
Alarm Details of the alarm The LED indication pattern
LOS LOS (Loss of Signal (Red Alarm))
No Signal (Analog Interface)
Following an alarm blink (red, green, red, green), a red
LED lighting up.
AIS AIS (Alarm Indication Signal (Blue
Alarm))
Following an alarm blink (red, green, red, green), a red
LED flashes on and off slowly twice
OOF OOF (Out of Frame (Red Alarm)) Following an alarm blink (red, green, red, green), a red
LED and a green LED flash on and off 3 times simultane-
ously.
RAI RAI (Remote Alarm Indication (Yellow
Alarm))
Following an alarm blink (red, green, red, green), a green
LED flashes on and off twice.
No alarm System does LED control
E1 Alarm Mode
Refer to following figure for LED pattern information. LED indications for the E1 are listed in
Table 2-16 E1 LED Indications on page 2-58.
ISSUE 4.0 SL1000
Hardware Manual 2-57
LOS
AIS
OOF
RAI
TS16
1 cycle 3.8 sec (120ms x 32=3840 ms)
red
green
red
green
red
green
red
green
red
green
120 ms
Figure 2-82 1PRIU-C1 LED Indication Pattern of Layer 1 on E1 Unit
Table 2-16 E1 LED Indications
Alarm Details of the alarm The LED indication pattern
LOS LOS (Loss of Signal (Red Alarm))
No Signal (Analog Interface)
Following an alarm blink (red, green, red, green), a red
LED lighting up.
AIS AIS (Alarm Indication Signal (Blue
Alarm))
Following an alarm blink (red, green, red, green), a red
LED flashes on and off slowly twice
OOF OOF (Out of Frame (Red Alarm)) Following an alarm blink (red, green, red, green), a red
LED and a green LED flash on and off 3 times simultane-
ously.
RAI RAI (Remote Alarm Indication (Yellow
Alarm))
Following an alarm blink (red, green, red, green), a green
LED flashes on and off twice.
TS16 TS16 (Receive Time Slot 16 all Alarm) An alarm blink repeat twice by 1 cycle.
No alarm System does LED control
3.5 Power Failure Transfer (408E-A1 only)
3.5.1 General
In the event of AC power failure, the specified trunks are directly connected to the specified extension
ports as below. And SLT must be connected to the specified extension. The multiline telephone (4W)
does not work when connected to the specified extension port.
Trunk Port No. 5 Extension Port No. 16
Trunk Port No. 9 Extension Port No. 24
Trunk Port No. 13 Extension Port No. 32
SL1000 ISSUE 4.0
2-58 Installation
The connected extension must be SLT (Single Line Telephone).
Hardware switch (J6) must be set from "KT" to "PF" side (default: KT) when use the Power failure
transfer circuit.
Refer to Power Failure Transfer on page 2-17 for Power Failure Transfer of 408M-A1.
3.5.2 Power Failure Setting
Hardware switch (J6) must be set from "KT" to "PF" side (default: KT) when use the Power failure
transfer circuit.
1. Use Needle-nose pliers to change the switch position of "J6" from "KT" to "PF" as below.
(Default: KT)
J6
PF
Port
PF KT PF KT
Multiline
Telephone
PF
Port
Multiline
Telephone
Figure 2-83 PF/KT Switch of 408E-A1
2. Connect SLT to the extension port No. 16/24/32.
ISSUE 4.0 SL1000
Hardware Manual 2-59
SECTION 4 INSTALLING THE OPTIONAL INTERFACE CARDS
4.1 Installing the Expansion Memory Card (MEMDB-C1)
4.1.1 General
The Memory expansion daughter board (IP4[ ]-MEMDB-C1) provides additional memory for the
system to use following features;
A System with multiple KSUs
To use VoIP Card (IP4WW-VOIPDB-C1)
Remote Upgrade (Main Software)
E-Mail Notification (InMail)
VRS Channel increase from 4 to 16 channels
VRS/InMail channel increase from 8 to 16 channels
This daughter board is mounted on the CPU card and provides the SDRAM and flash memories.
4.1.2 Unpacking
Table 2-17 MEMDB-C1 Packing List
Items List of Contents QTY
IP4[ ]-MEMDB-C1 MEMDB-C1 PCB 1
4.1.3 Installing the MEMDB PCB
Do not remove or install the CPU card with power on.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main
KSU.
1. Turn off the system power and disconnect AC cord.
2. Open and remove the Sub-Cover.
Sub-Cover
Sub-Cover
Tab
Tab
Figure 2-84 Removing the Sub-Cover
SL1000 ISSUE 4.0
2-60 Installation
3. Loosen two screws and remove the Main-Cover.
Two screws
Hooks
Main-Cover
Figure 2-85 Removing the Main-Cover
4. Press tab A and lift the CPU support bracket. Remove the CPU card.
CPU support
CPU card
408M-A1 at 1632M KSU
A
Figure 2-86 Removing the CPU Card
ISSUE 4.0 SL1000
Hardware Manual 2-61
5. Insert the MEMDB-C1 daughter board to J4 socket on the CPU card and press down the
MEMDB-C1 daughter board to secure.
Both levers must be secured to notch-A.
Notch-B
J4
Notch-A
Lever
CPU card
MEMDB-C1 PCB
Figure 2-87 Installing the MEMDB PCB
6. Reinstall the CPU card into the 408M-A1 mother board, and close the CPU support making sure
the tab A locks into place.
CPU support
CPU card
408M-A1 at 1632M KSU
Figure 2-88 Installing the CPU Card
SL1000 ISSUE 4.0
2-62 Installation
7. Replace the Main-Cover and fasten two screws.
Two screws
Hooks
Main-Cover
Figure 2-89 Replacing the Main-Cover
4.2 VoIP Card (VOIPDB-C1)
4.2.1 General
The IP4WW-VOIPDB-C1 daughter board is used to convert the RTP (Real Time Transfer Protocol)
packets via the IP Network and PCM highway. The daughter board is installed on the CPU card.
4.2.2 Unpacking
Table 2-18 VOIPDB-C1 Packing List
Items List of Contents QTY
IP4WW-VOIPDB-C1 IP4WW-VOIPDB-C1 1
Ferrite Core (for Ethernet Cable) 1
4.2.3 Installing the VOIPDB-C1 PCB
Do not remove or install the CPU Card with the power on.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main
KSU.
1. Turn off the system power and disconnect AC cord.
ISSUE 4.0 SL1000
Hardware Manual 2-63
2. Open and remove the Sub-Cover.
Sub-Cover
Sub-Cover
Tab
Tab
Figure 2-90 Removing the Sub-Cover
3. Loosen two screws and remove the Main-Cover.
Two screws
Hooks
Main-Cover
Figure 2-91 Removing the Main-Cover
SL1000 ISSUE 4.0
2-64 Installation
4. Press tab A and lift the CPU support bracket. Remove the CPU card.
CPU support
CPU card
408M-A1 at 1632M KSU
A
Figure 2-92 Removing the CPU Card
5. Install the VOIPDB-C1 daughter board to J5 connector on the CPU card.
CPU card
J5
VOIPDB-C1 PCB
Nylon-Spacers
Nylon-Spacers
Figure 2-93 Installing the VOIPDB-C1 PCB
ISSUE 4.0 SL1000
Hardware Manual 2-65
6. Reinstall the CPU card into the 408M-A1 mother board, and close the CPU Support making sure
tab A locks into place.
CPU support
CPU card
408M-A1 at 1632M KSU
Figure 2-94 Installing the CPU Card
7. Cut and remove the Plastic Knockout for VoIP connector, then replace the Main-Cover and fasten
two screws.
Two screws
Main-Cover
Plastic
Knockout
Hooks
Figure 2-95 Removing the Plastic Knockout and Replacing the Main-Cover
SL1000 ISSUE 4.0
2-66 Installation
8. Connect the VOIPDB-C1 to an Switching hub using an LAN Cable.
The LAN Cable must pass two times (two rounds) through the Ferrite Core as below. (Ferrite
Core is attached with VOIPDB-C1)
VOIPDB-C1 board (CN1)
Ferrite Core
V
O
I
P
to HUB
LAN Cable
30 - 50 mm
(1.181 - 1.967)
Pass 2 times
< Bottom View >
Figure 2-96 Connecting a LAN Cable
9. Refer to the SL1000 Programming Manual for detailed programming instructions.
The VoIP feature requires system configuration.
4.2.4 LED Indication
LED indications for the IP4WW-VOIPDB-C1 are listed Table 2-19 VOIPDB LED Indications on
page 2-68. Each LED is listed with its associated function and operational status.
VOIPDB-C1
board
LINK10
LINK100
LINK1000
ACT
< Bottom View >
Figure 2-97 Location of LEDs
ISSUE 4.0 SL1000
Hardware Manual 2-67
Table 2-19 VOIPDB LED Indications
LED Function LED Status Operation status
ACT Link activity or data transmission and re-
ception.
On Green LED lights when link up is completed. LED flash
when data is transmitting or receiving.
LINK1000 1000Base-T link speed indicator On Yellow Lights up when 1000Base-T link up.
LINK100 100Base-TX link speed indicator. On Red Lights up when 100Base-TX link up.
LINK10 10Base-TX link speed indicator. On Red Lights up when 10Base-T link up.
Table 2-20 Operation of VOIPDB LED Indications
LED Operation status
ACT LINK1000 LINK100 LINK10
Off Off Flash Flash Internal Error (Hardware Error)
Off On Flash Flash
On On Flash Flash
On Off Flash Flash State of half duplex transmission (Not support)
Please change HUB etc. to full duplex transmission.
Flash Blinking one by one The firmware is being updated.
4.3 VRS/Voice Mail Card (PZ-VM21)
4.3.1 General
The PZ-VM21 daughter board provides additional DSP resource with 8/16 ch VRS (Voice Response
system) and Voice Mail Service (a compact flash card (CFVRS/CFVMS/CFVML) is required) and a
Single Channel V.34 (33.6 kbps) modem for remote maintenance functions. The daughter board is
installed onto the CPU card.
4.3.2 Unpacking
Table 2-21 PZ-VM21 Packing List
Items List of Contents QTY
PZ-VM21 PZ-VM21 PCB 1
Nylon Spacers 4
4.3.3 Installing the PZ-VM21 PCB
Do not remove or install the CPU Card with the power on.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main
KSU.
1. Turn off the system power and disconnect AC cord.
SL1000 ISSUE 4.0
2-68 Installation
2. Open and remove the Sub-Cover.
Sub-Cover
Sub-Cover
Tab
Tab
Figure 2-98 Removing the Sub-Cover
3. Loosen two screws and remove the Main-Cover.
Two screws
Hooks
Main-Cover
Figure 2-99 Removing the Main-Cover
ISSUE 4.0 SL1000
Hardware Manual 2-69
4. Press tab A and lift the CPU support bracket. Remove the CPU card.
CPU support
CPU card
408M-A1 at 1632M KSU
A
Figure 2-100 Removing the CPU Card
5. Connect the PZ-VM21 daughter board to the J6 connector using four Nylon-spacers on the CPU
card.
CPU card
J6
PZ-VM21 PCB
CN1
Nylon-spacers
Nylon-spacers
Figure 2-101 Installing the PZ-VM21 PCB
SL1000 ISSUE 4.0
2-70 Installation
6. Reinstall the CPU card into the 408M-A1 mother board, and close the CPU Support making sure
tab A locks into place.
CPU support
CPU card
408M-A1 at 1632M KSU
Figure 2-102 Installing the CPU Card
7. Replace the Main-Cover and fasten two screws.
Two screws
Hooks
Main-Cover
Figure 2-103 Replacing the Main-Cover
4.4 Installing the CF Card (CFVRS/CFVMS/CFVML)
Do not remove or install the CPU Card with the power on.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main
KSU.
When installing a compact flash card onto the PZ-VM21 the system MUST
be powered off. Never install or uninstall the compact flash card while the
system is under power.
1. Turn off the system power and disconnect AC cord.
ISSUE 4.0 SL1000
Hardware Manual 2-71
2. Remove the CPU card and insert the compact flash card into the CF slot (CN2).
CF card
CF Slot (CN2)
CPU card
PZ-VM21 PCB
Figure 2-104 Installing the CF Card
3. Reinstall the CPU card into the 408M-A1 mother board, and close the CPU Support making sure
tab A locks into place.
SL1000 ISSUE 4.0
2-72 Installation
SECTION 5 INSTALLING THE MULTILINE TELEPHONES AND
OPTIONAL TERMINALS
5.1 Installing the Multiline Telephones
There are three types of Multiline Telephones available in the SL1000 system.
IP4WW-12TXH-A-TEL
IP4WW-24TXH-A-TEL
IP4WW-24TIXH-C-TEL (IP)
5.1.1 Location of Controls
Exit Help
Flash
Clear/Back
ABC
GHI JKL MNO
PQRS TUV WXYZ
DEF
Hold Speaker
1 2 3
4 5 6
7 8 9
0
Mute DND/CONF
Transfer
Handset
Exit
Alphanumeric Display
Indicator
Help
Programmable
function keys
24T[ ]XH only
Dial keys
Hold
Speaker
Speaker
Flash
Transfer
DND/CONF(12TXH/24TXH)
DND(24TIXH)
Mute
Clear/Back
Cursor control key
Light Sensor(24TIXH)
Soft key(24TIXH)
Figure 2-105 Multiline Telephone (12TXH/24TXH/24TIXH (IP))
Table 2-22 Multiline Telephone Functions (12TXH/24TXH/24TIXH (IP))
Functions 12TXH 24TXH 24TIXH
Programmable Keys 12
(Busy lamp field: Red-Green)
24
(Busy lamp field: Red-Green)
24
(Busy lamp field: Red-Green)
Display 16-digit x 2 lines 16-digit x 2 lines 24-digit x 3 lines with Backlit
Handsfree Half-duplex Half-duplex Full-duplex
Wall-Mount Kit Yes (Built-in) Yes (Built-in) Yes (Optional)
SoftKeys No No Yes
ISSUE 4.0 SL1000
Hardware Manual 2-73
Functions 12TXH 24TXH 24TIXH
Backlit Dial Pad No No Yes
Incoming LED No No 2 colors (Red/Green)
Connected to Hybrid Extension Port Hybrid Extension Port Ethernet Port on the Network
Headset Port No No Yes
Power Feeding - - AC Adapter (DC27 V,1 A) or PoE
(IEEE802.3af)
5.1.2 Multiline Telephone Legs Adjustment
The Multiline Telephone provides adjustable legs for angling the phone to best suit each user. The leg
can be set for two different heights (Low/High).
5.1.2.1 Low Position Setting
1. Turn telephone over (button side down).
2. Adjust the legs to desired height.
< Low position >
Leg
Figure 2-106 Leg Setting for Low Position
3. Lead the Line and Handset cords through the applicable grooves.
Telephone
line cord
Handset cord
< Bottom view>
Figure 2-107 Cabling of Multiline Telephone
4. Turn telephone over (button side up).
SL1000 ISSUE 4.0
2-74 Installation
5.1.2.2 High position setting
1. Turn telephone over (button side down).
2. Pull up the Leg Stoppers.
Leg
Leg Stopper
Figure 2-108 Setting for High Position
3. Adjust the leg to desired height.
Leg
< High position >
Figure 2-109 Leg Setting for High Position
4. Lead the Line and Handset cords through the applicable grooves.
(Refer to Figure 2-107 Cabling of Multiline Telephone on page 2-74)
ISSUE 4.0 SL1000
Hardware Manual 2-75
5.1.3 Wall-Mounting the Multiline Telephone
1. Arrange the cables and put down the leg as shown below.
Leg
< Bottom view>
Telephone
line cord
Handset cord
Figure 2-110 Cabling for Wall-Mount
For IP4WW-24TIXH-C only:
When wall-mounting the IP4WW-24TIXH-C, attach the IP4WW-WALL MOUNT UNIT to the bottom
panel as shown.
Claws
IP4WW-24TIXH-C
Claws
IP4WW-WALL
MOUNT UNIT
Figure 2-111 Wall-Mount Unit - 24TIXH-C
SL1000 ISSUE 4.0
2-76 Installation
2. Remove the switch-hook from the unit. Turn the tab toward the top. Then slide the hook-switch
into position. Refer to Figure 2-112 Hook-Switch Hanger on page 2-77.
Hook-switch hanger Hook-switch hanger
Figure 2-112 Hook-Switch Hanger
3. Install two screws into a wall. The screw heads must be remained about 3 mm (0.12).
7 - 9.5 mm
(0.28 - 0.37)
83.5 mm
(3.287)
Minimum 10 mm (0.39)
3 - 4 mm
(0.12 - 0.16)
1 - 3 mm
(0.04 - 0.12)
Figure 2-113 Wall-Mount Screw Guide
4. Mount the telephone on the wall.
Wall-mounting
holes
Wall side
Figure 2-114 Mounting the Multiline Telephone
ISSUE 4.0 SL1000
Hardware Manual 2-77
5.2 Install the IP Multiline Telephone (IP4WW-24TIXH-C1 TEL)
5.2.1 System Connection
The IP Multiline Telephone is connected via HUB.
LAN Cable
(10BASE-T/100BASE-TX)
IP Multiline Telephone
LAN(=) Connector
PC (X)Connector
Ferrite Core
VOIPDB-C1
board (CN1)
KSU
Commercial Power
Commercial Power PC
AC-[ ]
UNIT
Hub
Exit Help
Flash
Clear/Back
ABC
GHI JKL MNO
PQRS TUV WXYZ
DEF
Hold Speaker
1 2 3
4 5 6
7 8 9
0
Mute DND
Transfer
Figure 2-115 IP Multiline Telephone Connection
5.2.2 Installing the IP Multiline Telephone
1. Connect the LAN Network 10Base-T/100Base-TX cable to the LAN(=) connector.
2. If the Power feeding is used by AC-[ ] UNIT, plug the AC-[ ] UNIT cable to the DC input jack on
the IP Multiline Telephone Base.
3. The IP Multiline Telephone has a Switching HUB to connect a PC to the LAN Network. Connect
the 10Base-T/100Base-TX straight cable used for connection to the PC to the PC(X) connector
and to the PC.
PC(X) LAN(=)
< Bottom view>
PC(X) LAN(=)
Figure 2-116 IP Multiline Telephone Connectors
SL1000 ISSUE 4.0
2-78 Installation
5.2.3 Applying Power to the IP Multiline Telephone
IP Multiline Telephone (IP4WW-24TIXH-C1) supports two different power sources for the Telephone.
AC-LE UNIT
Plug the Optional AC-[ ] AC adapter input jack in the telephone base unit, and plug the 2-prong wall
plug of the AC adapter in AC outlet.
PoE(IEEE802.3af)
PoE (Power Over Ethernet) is a LAN technology that allows standard 10Base-T/100Base-TX data
cables to pass electrical current from a power source to a requesting end device.
5.3 Installing the DSS Console
The 60D DSS-A Console can be installed on the last hybrid extension ports (ST8/ST16/ST24) of each
408M-A1/408E-A1/008M-A1 card directly. The pair extension for the DSS Console is assigned using
system programming.
5.3.1 DSS Console Leg Adjustment
The DSS Console provides the leg for angling the console to best suit each user. The leg can be set
for two different heights (Low/High).
5.3.1.1 Low Position Setting
1. Turn DSS Console over (button side down).
2. Adjust the legs to desired height.
< Low position >
Leg
Figure 2-117 Low Position Setting
ISSUE 4.0 SL1000
Hardware Manual 2-79
3. Lead the Line cord through the applicable grooves.
Figure 2-118 Cabling of DSS
5.3.1.2 High position setting
1. Turn DSS Console over (button side down).
2. Pull up the Leg Stoppers.
Leg Stopper
Figure 2-119 Leg Stopper of DSS Console
SL1000 ISSUE 4.0
2-80 Installation
3. Adjust the leg to desired height.
< High position >
Leg
Figure 2-120 High Position Setting
4. Lead the Line cord through the applicable grooves.
(Refer to Figure 2-118 Cabling of DSS on page 2-80)
5.3.2 Wall-Mounting the DSS Console
1. Lift the leg and lead the cable through the applicable grooves. Refer to Figure 2-121 Cabling for
Wall-Mount on page 2-81. Lower leg to stowed position.
< Bottom view>
Leg
Figure 2-121 Cabling for Wall-Mount
ISSUE 4.0 SL1000
Hardware Manual 2-81
2. Install two screws into a wall. The screw heads must be remained about 3 mm (0.12).
7 - 9.5 mm
(0.28 - 0.37)
83.5 mm
(3.287)
Minimum 10 mm (0.39)
3 - 4 mm
(0.12 - 0.16)
1 - 3 mm
(0.04 - 0.12)
Figure 2-122 Wall-Mount Screw Guide
3. Mount the DSS Console to the wall.
Wall-mounting
holes
Wall side
Figure 2-123 Mounting the DSS
5.4 Installing the Headset
The Multiline Telephone user can utilize a customer-provided headset in place of the handset. Like
using Handsfree, using the headset frees up the user's hands for other work. However, Headset
Operation provides privacy not available from Handsfree.
For 4-wire multiline telephone
1. Remove the Handset cord from the Multiline Telephone.
SL1000 ISSUE 4.0
2-82 Installation
2. Connect the Headset cord into the Handset socket.
Handset socket
< Bottom view>
Figure 2-124 Handset Socket
For IP multiline telephone
1. Connect the Headset cord into the Headset socket.
PC(X) LAN(=)
AN(=)
Headset socket
< Bottom view>
Figure 2-125 Headset Socket
The headset configuration is assigned using system programming.
5.5 Installing the Doorphone Box
5.5.1 Wall-Mounting the Doorphone
1. Remove the screw on the front of the Doorphone Box.
2. Remove the Wall-Mount bracket from the Doorphone Box.
ISSUE 4.0 SL1000
Hardware Manual 2-83
3. Connect the cable to the screw terminals on the Doorphone box. (No polarity sensitive)
Screw
Upper housing
Connect cable
Wall-mount
bracket
Screw
terminals
Figure 2-126 Doorphone Box and Bracket
4. Mount the Wall-Mount bracket on the wall using supplied screws.
5. Replace the Upper housing and tighten the screw.
Upper housing
Hook
Attached screws
Hole
Screw
Wall-mount
bracket
Figure 2-127 Doorphone
SL1000 ISSUE 4.0
2-84 Installation
5.5.2 Connecting the Doorphone
Wire position for each port Port position
ST6 ST7
ST6 or ST7
T R
Doorphone
Modular cable
(2-wire, Straight)
T R
Figure 2-128 Connecting the Doorphone
The Doorphone configuration is assigned using system programming.
The 3
rd
party Doorphone Boxes cannot be connected to the port.
5.5.3 Doorphone Interface Specifications
Table 2-23 Doorphone Interface Specifications
Item Specification
Output Impedance 600
Output Level Nominal 250 mV (-10 dBm)
Maximum Output 400 mV RMS
5.6 Installing the Door Unlock Devices
A maximum of two door unlock devices can be connected to each KSU.
ISSUE 4.0 SL1000
Hardware Manual 2-85
J7 (RJ61)
RY1/2
Door unlock control devices
87654321
Figure 2-129 Connecting the Door Unlock Device
The following table shows the pin-outs for the RJ-61 cable connector.
Table 2-24 RJ-61 General Purpose/Door Unlock Relay Control Connector (J7)
Pin No. Connection
87654321
RY1/2 (J7)
1 -
2 -
3 Relay 2
4 Relay 1
5 Relay 1
6 Relay 2
7 -
8 -
Table 2-25 General Purpose/Door Unlock Relay Specifications
Item Specification
Rated Voltage DC 48 V Maximum
Rated Current DC 320 mA Maximum
Contact Normally Open
SL1000 ISSUE 4.0
2-86 Installation
5.7 Installing the External Paging Speaker/External MOH/BGM Sources
5.7.1 Connecting the Audio Equipment
The trunk ports CO2 to CO4 can be used for audio port (External paging, External MOH, BGM)
Audio port configuration is assigned using system programming.
External paging can be set for the 408M-A1 PCB of each KSU except 3rd Expansion KSU.
The External MOH and BGM can be set for the 408M-A1 PCB of the Main KSU only.
Wire position for each port Trunk port position
CO2 or Audio in/out
(External paging)
CO3 or Audio in
(External MOH)
CO4 or Audio in
(BGM)
CO1 CO2 CO3 CO4
T R
T
CO2
(Non polarity)
Paging system Audio resource
CO3, CO4
R T R
Modular cable
(2-wire, Straight)
Figure 2-130 Connecting Audio Equipment
5.7.2 External Paging Output Specifications
Table 2-26 External Paging Output Specifications
Item Specification
Output Impedance 600 @ 1kHz
Output Level Nominal 250 mV (-10 dBm)
ISSUE 4.0 SL1000
Hardware Manual 2-87
Item Specification
Maximum Output 400 mV RMS
5.7.3 BGM/External MOH Source Input Specifications
Table 2-27 BGM/External MOH Source Input Specifications
Item Specification
Input Impedance 600 @ 1 kHz
Input Level Nominal 250 mV (-10 dBm)
Maximum Input 1 V RMS
5.8 SMDR (Station Message Detail Recording)
5.8.1 General
SMDR (Station Message Detail Recording) provides a record of the system's outside calls. Typically,
the record outputs to a customer-provided SMDR device such as PC via LAN port (J3) on the CPU
card.
J3 (RJ45)
LAN connector
PC
Hub
87654321
Figure 2-131 Connecting a PC for SMDR
1. Connect the straight type Ethernet cable (CAT5) between the system and In-house LAN.
The SMDR feature is assigned using system programming.
SL1000 ISSUE 4.0
2-88 Installation
System Start Up
SECTION 1 SYSTEM START UP
1.1 Before Starting Up the System
Before starting up the system, make sure:
KSU(s) are installed correctly.
All extensions are cabled correctly.
All earth ground and PSTN Trunks are cabled correctly.
All PCBs are configured, equipped, and secured correctly.
AC power cord is cabled correctly.
At least one display type Multiline Telephone is connected to the system. (for Programming)
Pull out the Lithium battery protection sheet, before starting up the system.
Lithium battery protection sheet
Figure 3-1 Lithium Battery Protection Sheet
If Expansion KSU(s) are installed, turn the power on/off in the order of Expansion 3 KSU, Expansion
2 KSU, Expansion 1 KSU and then Main KSU.
1.2 Starting Up the System
There are two methods for startup (COLD Start and HOT Start).
Table 3-1 Start Up Method
Start Up Method Description Purpose
COLD Start The factory setting data is loaded. First time start up
System Initialization
HOT Start The customer setting data is loaded. System Reboot
Hardware Manual 3-1
S
y
s
t
e
m

S
t
a
r
t

U
p
3
1.2.1 Perform a Cold Start
This section describes the process for starting the system for the first time or starting a system that
requires the customer data be deleted.
System software is loaded from flash memory, and the customer data is deleted
from RAM memory.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main KSU.
To perform a Cold Start;
1. Set the power switch to off position.
Figure 3-2 Power Switch Location
2. Open the Sub-Cover on the Main KSU and identify the LOAD button (S1) location on the CPU
card.
Sub-Cover
Tab
< Front view >
S1
L
O
A
D
CPU card
Tab
Figure 3-3 Load Button (S1) Location
3. Once the system has powered off, push in and hold the LOAD button (S1).
If Expansion KSU(s) are installed, the Power Switch must be ON at
Expansion KSU(s).
SL1000 ISSUE 4.0
3-2 System Start Up
4. Turn the power switch ON at the Main KSU.
5. Continue holding the LOAD button (S1) for approximately three seconds or until Status LED (D5)
starts flashing red.
< Front view >
RUN LED
LED (D5)
Figure 3-4 Status LED (D5) and RUN LED Location
6. Release the LOAD button.
7. When the system has completed reloading the software (about two minutes), the RUN LED is
flashing blue on the CPU card and the connected Multiline Telephone's display will show the Time
& Date and Extension Number.
TUE18 7:27PM
200
Figure 3-5 Display Indication (Idle)
1.2.2 Perform a Hot Start
This section describes how to load system software from flash memory, and the customer data from
RAM memory.
System software is loaded from flash memory, and the customer data is loaded
from RAM memory.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main KSU.
To perform a Hot Start;
1. Turn the system power off.
2. After it has powered off, turn the power switch back to ON. Wait approximately two minutes.
3. When the system has completed reloading the software, the RUN LED is flashing blue on the
CPU card, and the connected Multiline Telephone's display will show the Time & Date and
Extension Number as Figure 3-5 Display Indication (Idle) on page 3-3.
ISSUE 4.0 SL1000
Hardware Manual 3-3
SECTION 2 PROGRAMMING MODE
2.1 Entering the Programming Mode
The installer/system administrator can enter to the system programming mode from the Display Type
Multiline Telephone. (A maximum of two users can enter mode at the same time)
In a newly installed system, use extension port 1.
1. Press Speaker key. (Do not lift the handset)
2. Dial #
*
#
*
.
Password
TUE18 7:27PM
200
Figure 3-6 Entering Programming Mode Display 1
3. Dial the system password, then press Hold key to enter the Program Mode.
Password@@@@@@@@ Program Mode
Figure 3-7 Entering Programming Mode Display 2
For the details of programming, refer to the SL1000 Programming Manual. (separate issue)
2.2 Exiting the Programming Mode
1. Press Mute key several times to return to the "Program Mode" Screen.
10-01- Sys
Time&Data Setup Program Mode
Figure 3-8 Exiting the Programming Mode Display 1
2. Press Speaker key to exit.
Program Mode
TUE18 7:27PM
200
Figure 3-9 Exiting Programming Mode Display 2
The system automatically saves the customer data to the memory which is backed up by lithium
battery.
2.3 Saving (Backup) the Customer Data
When the installer/system administrator exits from the programming mode, the system will
automatically save the customer data to the on-board memory which is backed up by lithium battery.
Additionally, the customer data can be saved to a CF Card for backup purpose. The PZ-VM21
daughter board must be installed to the CPU card with a BLANK CF card inserted.
SL1000 ISSUE 4.0
3-4 System Start Up
For the details of PZ-VM21 daughter board installation, refer to Installing the PZ-VM21 PCB on
page 2-68.
1. Turn the system power off, insert the blank CF card (32 MB or larger) to the CF slot on PZ-VM21.
CPU card
CF Slot (CN2)
CF card
PZ-VM21 PCB
Figure 3-10 Inserting the CF card
2. Turn the power on, enter the Program Mode then PRG90-03.
Program Mode
90-03-01
Data Save
Figure 3-11 PRG90-03 Display
3. Dial 1 and press Hold key.
4. When the data backup to the CF card is completed, the display will be changed to the next PRG.
90-03-01
SavingSystemData
90-04- M
,
tenanc
Load Data
Figure 3-12 PRG90-04 Display
5. Remove the CF Card and exit from the Programming Mode.
The saved data on CF Card cannot be edited by the PC.
2.4 Loading the Customer Data
The backed up customer data can be loaded to the system by CF Card. The PZ-VM21 daughter board
must be installed to the CPU card with a CF card inserted that the saved customer data loaded.
For the details of PZ-VM21 daughter board installation, refer to Installing the PZ-VM21 PCB on
page 2-68.
ISSUE 4.0 SL1000
Hardware Manual 3-5
1. Turn the power off, insert the Customer Data CF card into the CF Slot on PZ-VM21.
CPU card
CF Slot (CN2)
CF card
PZ-VM21 PCB
Figure 3-13 Inserting the CF card
2. Turn the power on, enter the Program Mode then PRG90-04.
Program Mode
90-04-01
Data Load
Figure 3-14 PRG90-04 Display
3. Dial 1 and press Hold key.
4. When the data backup to the CF card is completed, the display changes to the next PRG.
90-04-01
Loading Data
90-05- M
,
tenanc
Slot Control
Figure 3-15 Next PRG Display
5. Remove the CF card and exit from the Program Mode.
SL1000 ISSUE 4.0
3-6 System Start Up
SECTION 3 SYSTEM SHUT DOWN
3.1 Powering Off the System
1. Turn the all KSU(s) power off using the power switch.
Figure 3-16 Power Switch Location
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main
KSU.
DO NOT power off by disconnecting the AC (or DC for battery backup)
power. Always use the Power Switch on the Main/Expansion KSU.
All calls in progress will be cut off when the system is powered off, and if
the Power Failure is set, the applicable extension will become
operational.
All user's setting (such as Call Forward, Camp-On, etc) will be kept.
3.2 Resetting the System
The system reset is carried out using the "Power OFF and ON" operation.
ISSUE 4.0 SL1000
Hardware Manual 3-7
MEMO
SL1000 ISSUE 4.0
3-8 System Start Up
Maintenance
SECTION 1 FUSE REPLACEMENT
1.1 Replacing the Fuse
This fuse is only for external battery box connection, it is not used for AC
power to the system.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main KSU.
1. Turn off the system power and disconnect AC cord.
2. Open and remove the Sub-Cover.
Sub-Cover
Sub-Cover
Tab
Tab
Figure 4-1 Removing the Sub-Cover
Hardware Manual 4-1
M
a
i
n
t
e
n
a
n
c
e
4
3. Loosen two screws and remove the Main-Cover.
Two screws
Hooks
Main-Cover
Figure 4-2 Removing the Main-Cover
4. Exchange the fuse (250 V/8 A) on 408M-A1 PCB.
< Top View >
408M-A1
FUSE (8 A / 250 V)
Figure 4-3 Exchanging the Fuse
SL1000 ISSUE 4.0
4-2 Maintenance
5. Replace the Main-Cover and fasten two screws.
Two screws
Hooks
Main-Cover
Figure 4-4 Replacing the Main-Cover
ISSUE 4.0 SL1000
Hardware Manual 4-3
SECTION 2 LITHIUM BATTERY REPLACEMENT
2.1 General
The Lithium Battery (CR2032) is installed on the CPU Card in Main KSU. It provides the battery-
backup of the RAM memory for approximately 36 months. When the battery power becomes low, the
system will display a "Warning Message" to the assigned Display Multiline Telephone as below.
TUE 18 7:27PM
Low battery!

Figure 4-5 Warning of Low Battery
2.2 Lithium Battery Specification
Before replacing the Lithium battery, make sure which type of Lithium battery is required and prepare
the new Lithium battery. (CR2032)
NEC recommends that a backup of the customer data is performed before
powering off the system (either PCPro file or CF card backup) in order to
replace the backup battery.
Risk of explosion if the battery is replaced by an incorrect type.
Dispose of used batteries as instructed by the manufacturer of the battery.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main
KSU.
SL1000 ISSUE 4.0
4-4 Maintenance
2.3 Replacing the Lithium Battery
1. Remove the Sub-Cover at the Main KSU.
Sub-Cover
Tab
Tab
Figure 4-6 Removing the Sub-Cover
2. Power off the system, and remove the AC plug from the AC outlet.
3. Disconnect the AC power cord from the KSU.
AC power cord must be disconnected, otherwise the Main-Cover cannot be
opened.
Disconnect
AC Power Cord
Figure 4-7 Disconnecting the AC Power Cord
ISSUE 4.0 SL1000
Hardware Manual 4-5
4. Loosen two screws and remove the Main-Cover.
Two screws
Hooks
Main-Cover
Figure 4-8 Removing the Main-Cover
5. Press tab A and lift the CPU support bracket.
6. Remove CPU card from the Main KSU.
CPU support
CPU card
408M-A1 at 1632M KSU
A
Figure 4-9 Removing the CPU Card
SL1000 ISSUE 4.0
4-6 Maintenance
7. Refer to following figure for the Lithium battery location on the CPU card.
Battery socket < Conductor side >
J12
CPU card
Figure 4-10 Location of Lithium Battery Socket
8. Remove the old Lithium battery and insert the new one into the socket.
The polarity + symbol must be on top as illustrated in following figure.
Lithium battery
Socket
Figure 4-11 Removing the Lithium Battery
Lithium battery
Socket
Figure 4-12 Inserting the Lithium Battery
ISSUE 4.0 SL1000
Hardware Manual 4-7
9. Reinstall the CPU card into the 408M-A1 mother board and close the CPU support bracket.
CPU support
CPU card
408M-A1 at 1632M KSU
Figure 4-13 Installing the CPU Card
10. Replace the Main-Cover and Sub-Cover.
SL1000 ISSUE 4.0
4-8 Maintenance
SECTION 3 MAIN SOFTWARE UPGRADING
3.1 General
The main system software is initially stored in the Flash memory located on the CPU card of the Main
KSU. It can be upgraded by the new software on the CF (Compact Flash) card.
3.2 Before Upgrading the Main Software
NEC recommends that a backup of the customer data is performed before
upgrading the main software (either PCPro file or CF card backup).
Before upgrading the main system software, the following preparations are necessary.
Prepare the CF Card (32MB, or upwards and formatting by FAT(16)), and store the new main
software on the CF card by PC. (New main system software is supplied by NEC.)
Install the PZ-VM21 PCB. (if the system does not have it.)
3.3 Main Software Version Confirmation
The Main software version is confirmed by the following operation at the display type Multiline
Telephone.
1. On-hook Condition.
TUE18 7:27PM
200
Figure 4-14 Display of Multiline Telephone
2. Press Enter Key (Navigation Key).
100:OPRN LST 1/4
>Call History:00
3. Dial 821 to show the Main Software version & Hardware Key Code.
Main Ver: 01.00
HWK:XXXXXXXXXXXX
4. Press Right Key (Navigation Key) to show the Main Software version & MAC address.
Main Ver: 01.00
0060-XXXX-XXXX
5. Off-Hook and return to Time & Date mode.
TUE18 7:27PM
200
ISSUE 4.0 SL1000
Hardware Manual 4-9
3.4 Upgrading the Main Software
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU, Expansion 2 KSU, Expansion 1 KSU and then Main KSU.
1. Power off the system and disconnect the AC cord from the KSU.
2. Remove the Sub-Cover.
Sub-Cover
Tab
Tab
Figure 4-15 Removing the Sub-Cover
3. Loosen two screws and remove the Main-Cover.
Two screws
Hooks
Main-Cover
Figure 4-16 Removing the Main-Cover
SL1000 ISSUE 4.0
4-10 Maintenance
4. Insert the CF card (with the new main system software loaded) to the CF slot on PZ-VM21
daughter board. (PZ-VM21 should be temporary installed if not already fitted.)
CPU card
CF Slot (CN2)
CF card PZ-VM21 PCB
D3 (Red)
D1 (Blue)
D2 (Red)
D4 (Red)
D5 (Red)
Figure 4-17 Inserting the CF card
5. Push in and hold the LOAD button (S1 on the CPU card).
Sub-Cover
Tab
< Front view >
S1
L
O
A
D
CPU card
Tab
Figure 4-18 LOAD Button (S1) Location
6. Turn the system power on.
7. Continue holding the LOAD button (S1) for approximately 10 seconds or until Status LED (D5)
starts flashing red.
8. Release the LOAD button (S1).
9. Wait until the Status LEDs (D2 to D5) on the CPU card has the following indications
(approximately two minutes).
Table 4-1 Status LEDs
LED No. Indication Remarks
D2 Flashing Red
D3 Flashing Red
D4 Flashing Red
D5 Off
ISSUE 4.0 SL1000
Hardware Manual 4-11
10. Turn the power off and remove the CF card from the CF slot on PZ-VM21.
CPU card
CF Slot (CN2)
CF card
PZ-VM21 PCB
Figure 4-19 Removing the CF card
11. Replace the Main-Cover and Sub-Cover.
12. Turn the system power back on.
13. When the system has completed reloading the software, the RUN LED (D1) will flash blue.
To confirm the new software version number, press the Navigation key on any display telephone to
view the system version number see Main Software Version Confirmation on page 4-9.
The existing system data in the flash memory is replaced, but the customer data (stored in the RAM)
is saved.
SL1000 ISSUE 4.0
4-12 Maintenance
SECTION 4 LED INDICATIONS
The LEDs on the CPU indicate the following:
RUN (D1) = The CPU is operating (Blue)
D2, and D3 = Alarms (Red)
D4 = Flash access indication (Red)
D5 = Boot status (Red)
Refer to Program 90-10: System Alarm Setup for details on assigning alarm LEDs.
Table 4-2 CPU LED Indications on page 4-13 provides a list of each LED and associated operation
and status indications. Refer to Figure 4-17 Inserting the CF card on page 4-11 for the location of the
LEDs on the CPU.
Table 4-2 CPU LED Indications
Status LED Indication
RUN (D1) D2 D3 D4 D5
System Operating Normally Blinking Off Off Off Off
System Operate Normal + File accessing Blinking Off Off Access
Blinking
Off
System Starting Up On Off Off Off Off
Boot is starting On Off Off Off Blinking
Initializing the disk or formatting Blinking Off Off Off Off
Reading System Program Blinking Off On Access
Blinking
Off
Reading Error of System Program Off On Off Off Off
System Initializing + DSP loading process On Off On Access
Blinking
Off
Initializing System Program Blinking Off On Access
Blinking
Off
Upgrading System Program (in the Flash Memory) Off Blinking Off Access
Blinking
Off
Batch file Error Off On On Off Off
Completed the System Program Upgrade Off Blinking Blinking Blinking Off
Security Tip Error Off Blinking Off Off Off
Error alarm (Major) occurred Blinking Blinking Off Off Off
Error alarm (Minor) occurred Blinking Blinking Off Off Off
Shutting Down Blinking Off Off Off Off
Power Off Off Off Off Off Off
ISSUE 4.0 SL1000
Hardware Manual 4-13
MEMO
SL1000 ISSUE 4.0
4-14 Maintenance
Specifications
SECTION 1 SYSTEM CAPACITY
Table 5-1 System Capacity
Items 1 KSU
(1632)
2 KSU
(3264)
3 KSU
(4896)
4 KSU
(64128)
Note
Expansion Slot 3 6 9 12 *4th slot of each KSU can not be used
for 4w Key Set.
*4th KSU can not be used for COI,
2BRIDB and 1PRIU.
System Maximum Port 66 132 198 230 1KSU: 408M+PRI+408Ex2
2KSU: 408Mx2+PRIx2+408Ex4
3KSU: 408Mx3+PRIx3+408Ex6
4KSU: 408Mx4+PRIx3+408Ex6
+008Ex3-400Mx1(4th KSU)
Trunk Port Max. 42 84 126 126 1KSU: 408M+PRIx1+408Ex2
2KSU: 408Mx2+PRIx2+408Ex4
3/4KSU: 408Mx3+PRIx3+408Ex6
Trunk Port Analog Trunks
(COT)
16 32 48 48 1KSU: 408M+408Ex3
2KSU: (408M+408Ex3) x2
3/4KSU: (408M+408Ex3)x3
BRI 12 24 36 36 1KSU: 2BRIx3 on 008E/000E
2KSU: 2BRIx6
3/4KSU: 2BRIx9
PRI (E1) 30 60 90 90 Max. 1 PRI/KSU
Max. 3 PRI/sys
IP Trunk (SIP/H.
323)
16 When MEMDB is installed
External Paging
(Audio Out)
1 2 3 3 1 audio In/Out and 2 audio In circuits on
408M (COI port 2: Paging, 3: MOH, 4:
BGM) Need the Program Setting. Alterna-
tive use with COT
External MOH
(Audio In)
1
External BGM
(Audio In)
1
Station Port Max. 32 64 96 128 1KSU: 408M+408Ex3
2KSU: 408Mx2+408Ex6
3KSU: 408Mx3+408Ex9
4KSU: 408Mx4+408Ex12
Hardware Manual 5-1
S
p
e
c
i
f
i
c
a
t
i
o
n
s
5
Items 1 KSU
(1632)
2 KSU
(3264)
3 KSU
(4896)
4 KSU
(64128)
Note
Station Port 4W Key Set 24 48 72 96 Max. 24/KSU
SLT (28V) 32 64 96 128 1KSU: 408M+408Ex3
2KSU: 408Mx2+408Ex6
3KSU: 408Mx3+408Ex9
4KSU: 408Mx4+408Ex12
BRI (S-Point) 12 24 36 36 1KSU: 2BRIx3 on 008E/000E
2KSU: 2BRIx6 on 008E/000E
3KSU: 2BRIx9 on 008E/000E
4KSU: 2BRIx12 on 008E/000E
4W DSS Console 3 6 9 12 Max. 3/KSU
Connect to HBI Port 8 at 408M/408E/008E
Doorphone 2 4 6 8 2DPH I/F on 408M (HBI port 6,7)
Needs Program setting.
Alternative use with SLT
SIP-MLT/ SIP Std.
terminal
16 When MEMDB is installed
VRS Channels 4 CFVRS-C1
Max. 16 When MEMDB is installed
VM/VRS Channels 2 VM ports/ 4 VRS ports (default)
(Total Max.8 w/o MEMDB or 16 w/
MEMDB)
CFVMS-C1
Port increased by license.
4 VM ports/ 4 VRS ports (default)
(Total Max.8 w/o MEMDB or 16 w/
MEMDB)
CFVML-C1
Port increased by license.
Virtual Extension 50
Relay 2 4 6 8 2 circuits on 408M
Power Failure Transfer 4 8 12 12 1PFT circuit on 408M and 408E (COI port
1 and HBI port 8)
Needs HW switch change. Alternative use
with SLT.
Ethernet Port 1 1 circuit on CPU
Built-In Answering Machine Chan-
nel
1 1 circuit on CPU
VoIP Channels 16 When MEMDB is installed
V34 Modem 1 1 circuit on PZ-VM21
Conference Circuits 32 (Max. 16 parties per Conference) Mounted on CPU
DSP Resource
*1
20 For 1632M KSU (DSP on CPU)
16 When PZ-VM21 is installed
- 32 64 96 For 1632ME EXP 32ch DSP on each EX-
IFE-C1
DSP Sender
*2
128
*1. Service Tone receiver, DTMF receiver, Caller ID sender / receiver, MF receiver, MFC receiver
*2. Service Tone sender, DTMF sender, MF sender, MFC sender
SL1000 ISSUE 4.0
5-2 Specifications
SECTION 2 SYSTEM SPECIFICATIONS
2.1 General Precautions
Never attempt to insert wires, pins, etc. into the vents or other holes of the equipment.
Do not use benzene, thinner, or the like, or any abrasive powder to clean the equipment. Wipe it
with a soft cloth.
2.2 Environmental Requirements
Meeting established environmental standards maximizes the life of the system. Be sure that the site is
not:
In direct sunlight or in hot, cold or humid places.
In dusty areas or in areas where sulfuric gases are produced.
In places where shocks or vibrations are frequent or strong.
In places where water or other fluids comes in contact with the equipment.
In areas near high-frequency machines or electric welders.
Near computers, telexes, microwaves, air conditioners, etc.
Near radio antennas (including shortwave)
2.3 Operating Conditions
Table 5-2 Operating Conditions
Unit Operating Conditions
KSU, PCBs and Multiline Telephones Temperature: 0 to +40 degree C (32 to 104 degree F)
Humidity: 10 to 90% (non-condensing)
Doorphone Box Temperature: -20 to +60 degree C (-4 to 140 degree F)
Humidity: 20 to 80% (non-condensing)
2.4 Site Requirements
A KSU can only be wall-mounted, it can only be floor-mounted if the optional External Backup Battery
Box is installed.
2.5 AC Power Requirement
A dedicated 100V-120V/220V/230V/240V 50/60Hz circuit located within 2 meters of the KSU is
required. A separate dedicated AC outlet is necessary for each KSU.
Double Pole/Neutral Fusing
(Power supply fuses are located at both the L and N side.)
Table 5-3 Power Requirement
110 VAC 220 VAC 230 VAC 240 VAC
Power Require-
ments
110 VAC@15 A 220 VAC@15 A 230 VAC@15 A 240 VAC@15 A
Power Con-
sumption
Main KSU = 144 VA
4 KSU Total = 576 VA
Main KSU = 172 VA
4 KSU Total = 688 VA
Main KSU = 175 VA
4 KSU Total = 700 VA
Main KSU = 175 VA
4 KSU Total = 700 VA
Input Voltage
(Rated Voltage)
90 VAC to 264 VAC (100VAC/120VAC/220VAC/230VAC/240VAC)
ISSUE 4.0 SL1000
Hardware Manual 5-3
110 VAC 220 VAC 230 VAC 240 VAC
Frequency 47 Hz - 63 Hz (Rated Frequency:50/60 Hz)
Phase and Wire Single Phase, 2 Line + PE Type
Grounding Re-
quirement
No.14 AWG Copper Wire
Feeding Volt-
age
SLT: 20 mA/-27 V
AC Input I Main KSU = 1.31 A
4 KSU Total = 5.24 A
Main KSU = 0.78 A
4 KSU Total = 3.12 A
Main KSU = 0.76 A
4 KSU Total = 3.04 A
Main KSU = 0.73 A
4 KSU Total = 2.92 A
KWh Main KSU = 0.144 KWh
4 KSU Total = 0.576
KWh
Main KSU = 0.172 KWh
4 KSU Total = 0.688
KWh
Main KSU = 0.175 KWh
4 KSU Total = 0.700
KWh
Main KSU = 0.175 KWh
4 KSU Total = 0.700
KWh
BTU
(KWhx3413)
Main KSU = 491 BTU
4 KSU Total = 1964 BTU
Main KSU = 587 BTU
4 KSU Total = 2348 BTU
Main KSU = 597 BTU
4 KSU Total = 2388 BTU
Main KSU = 597 BTU
4 KSU Total = 2388 BTU
2.6 Electrical Specifications <Power Supply> (KSU)
Table 5-4 Electrical Specifications of KSU
Item Specification
Output Voltage -27 V (81 W)
Related Voltage -27 V
Load Fluctuation -25.92 V to -28 V (-27.0 V 4%)
Output Current 3.0 A
Ripple/Noise 200 mVp-p or less
Noise -65 dBm or less
Over Voltage Protection -31.2 V to -36.9 V
Over Current Protection 3.3 A to 3.9 A
Load Capacity 5000 F
2.7 CPU
SL1000
CONTROL SYSTEM Digital
MPU Manufacturer/ Name Freescale Semiconductor
PowerQUICC II Family MPC8248VRMIBA
MPU Architecture RISC (Reduced Instruction Set Computer), 32 Bit
Core Frequency 262.144 MHz
PROGRAM STOR-
AGE
Nor Flash 16 MB
DATA STORAGE SDRAM 32 MB x 2
SRAM 512 KB
SWITCHING (Time Division Matrix) 392 x 392 (Non-Blocking)
SL1000 ISSUE 4.0
5-4 Specifications
2.8 Traffic Capacity
Traffic Capacity Basic System Package Expanded System Package
Traffic Capacity 2540 BHCA 2540 BHCA
2540 Busy-Hour Call Attempts (BHCA) is based on a Full Capacity.
2.9 IP Terminal Power Chart
Table 5-5 IP Terminal Power Chart
IP Terminal
IEEE
802.3af
Class
Label Indication (Maximum Current with All Op-
tions)
Note
48 VDC 27 VDC
IP4WW-24TIXH-C TEL Class 2 130 mA 6.2 W 235 mA 6.3 W
2.10 IEEE802.af Class Specification
Table 5-6 IEEE802.af Class Specification
IEEE802.af Minimum Maximum
Class 2 3.84 W 6.49 W
2.11 Mechanical Specifications
Table 5-7 Mechanical Specifications
Equipment Width Depth Height Weight Note
1632M-A KSU, 1632ME-A
EXP
375 mm
(14.76 in)
115 mm
(4.53 in)
290 mm
(11.42 in)
Approx. 2 kg
(70.55 oz)

External Backup Battery 500 mm
(19.69 in)
230 mm
(90.55 in)
340 mm
(13.39 in)
10.3 kg (excluding battery)
(363.32 oz)
15.6 kg (including battery)
(550.27 oz)

4W Multiline Telephone 180 mm
(7.09 in)
221 mm
(8.70 in)
136 mm
(5.35 in)
0.85 kg
(29.98 oz)

IP Multiline Telephone 180 mm
(7.09 in)
221 mm
(8.70 in)
136 mm
(5.35 in)
0.90 kg
(31.75 oz)

DSS Console 122 mm
(4.80 in)
221 mm
(8.70 in)
113 mm
(4.45 in)
0.45 kg
(15.87 oz)

Doorphone 98 mm
(3.89 in)
28.5 mm
(1.12 in)
130 mm
(5.12 in)
0.2 kg
(7.05 oz)

2.12 Optional Unit Mechanical Specifications
Table 5-8 Optional Unit Mechanical Specifications
Unit Width Depth Height Weight Note
IP4[ ]-MEMDB-C1 67.5 mm
(2.66 in)
32 mm
(1.26 in)
2 mm
(0.08 in)
0.01 kg
(0.3 oz)

ISSUE 4.0 SL1000
Hardware Manual 5-5
Unit Width Depth Height Weight Note
IP4WW-VOIPDB-C1 66 mm
(2.60 in)
138 mm
(5.43 in)
18 mm
(0.71 in)
0.05 kg
(1.76 oz)

PZ-VM21 53 mm
(2.09 in)
85 mm
(3.35 in)
13 mm
(0.51 in)
0.03 kg
(1.06 oz)

IP4WW-408E-A1 160 mm
(6.30 in)
198 mm
(7.80 in)
32 mm
(1.26 in)
0.21 kg
(7.41 oz)

IP4WW-008E-A1 160 mm
(6.30 in)
198 mm
(7.80 in)
32 mm
(1.26 in)
0.18 kg
(6.35 oz)

IP4WW-000E-A1 160 mm
(6.30 in)
198 mm
(7.80 in)
32 mm
(1.26 in)
0.12 kg
(4.23 oz)

IP4WW-1PRIU-C1 160 mm
(6.30 in)
198 mm
(7.80 in)
32 mm
(1.26 in)
0.15 kg
(5.29 oz)

IP4WW-2BRIDB-C1 122 mm
(4.80 in)
168 mm
(6.61 in)
25 mm
(0.98 in)
0.09 kg
(3.17 oz)

IP4WW-EXIFB-C1 70 mm
(2.76 in)
115 mm
(4.53 in)
16 mm
(0.63 in)
0.04 kg
(1.41 oz)

IP4WW-CFVRS-C1 43 mm
(1.69 in)
37 mm
(1.46 in)
3.5 mm
(0.14 in)
0.01 kg
(0.35 oz)

IP4WW-CFVMS-C1 43 mm
(1.69 in)
37 mm
(1.46 in)
3.5 mm
(0.14 in)
0.01 kg
(0.35 oz)

IP4WW-CFVML-C1 43 mm
(1.69 in)
37 mm
(1.46 in)
3.5 mm
(0.14 in)
0.01 kg
(0.35 oz)

2.13 Doorphone Interface Specifications
Table 5-9 Doorphone Interface Specifications
Item Specification
Output Impedance 600
Output Level Nominal 250 mV (-10 dBm)
Maximum Output 400 mV RMS
2.14 General Purpose/Door Unlock Relay Specifications
Table 5-10 General Purpose/Door Unlock Relay Specifications
Item Specification
Rated Voltage DC 48 V Maximum
Rated Current DC 320 mA Maximum
Contact Normally Open
2.15 External Paging Output Specifications
Table 5-11 External Paging Output Specifications
Item Specification
Output Impedance 600 @ 1 kHz
Output Level Nominal 250 mV (-10 dBm)
SL1000 ISSUE 4.0
5-6 Specifications
Item Specification
Maximum Output 400 mV RMS
2.16 BGM/ExMOH Source Input Specifications
Table 5-12 BGM/External MOH Source Input Specifications
Item Specification
Output Impedance 600 @ 1 kHz
Input Level Nominal 250 mV (-10 dBm)
Maximum Input 1 V RMS
2.17 External Sensor Device Interface Specifications
Table 5-13 External Sensor Device Interface Specifications
Applied Voltage during
Sensor Off
Loop Current during Sensor
On
Port Assignment
24 V
40 mA
Program10-03-05: 0
5 V Program10-03-05: 1
The External Sensor device configuration shall be assigned by system program and the programming
is different with a Sensor Type.
2.18 CPU Card LAN Port Specifications
Table 5-14 CPU Card LAN Port Specifications
Item Specification
Standard IEEE802.3 10Base-T and 100Base-TX Compliant
Access CSMA/CD
I/F (Layer 1) Speed: 10 Mbps/100 Mbps Auto Negotiation
Cable: CAT5 or better, Straight/Cross Auto Crossover
2.19 Cabling Requirements
Do not run extension cable in parallel with the AC source, telex or computer etc. If the cables are
near cable runs to those devices, use shielded cable with grounded shields or install the cable in
conduit.
When cables must be run on the floor, cable protectors must be used.
Cable runs for Multiline Telephones, DSS Consoles, Single Line Telephones, and Doorphone Boxes
must be a dedicated, isolated cable pair.
Aerial distribution cabling is not allowed.
Trunk Lines must be installed with lightning protectors.
Do not use 4-wire cabling for SLT connections.
ISSUE 4.0 SL1000
Hardware Manual 5-7
2.20 Cable Requirements
Table 5-15 Cable Requirements
Device Cable Type Cable Run Length
Multiline Telephone 24 AWG (0.5 mm) 300 m (984.3 ft)
Multiline IP Telephone / Standard SIP
Phone (V4.0 Changed)
CAT5 Straight Cable 100 m (328.1 ft)
DSS Console 24 AWG (0.5 mm) 300 m (984.3 ft)
Single Line Telephone Analog Terminals
(20mA)
24 AWG (0.5 mm) 1,125 m (3,691ft)
Doorphone Box 24 AWG (0.5 mm) 150 m (492.1 ft)
CPU LAN Port to External Device Ethernet Cross Cable 100 m (328.1 ft)
CPU LAN Port to Switching Hub Ethernet Straight Cable 100 m (328.1 ft)
ISDN Terminal 4-wire, 24 AWG (0.5 mm) 100 m (328.1 ft)
(P-MP Short -passive)
300 m (984.3 ft)
(P-MP Long -passive)
500 m (1,640.4 ft)
(P-P)
1632ME-A EXP Ethernet Straight Cable (Attached to
1632ME-A EXP)
1.2 m (3.9 ft)
SL1000 ISSUE 4.0
5-8 Specifications